At least 199 records · Page 11

Guest Editorial for Nondestructive Testing and Evaluation (NDT&E) Special Section

Nondestructive testing and evaluation (NDT&E) are interdisciplinary fields that require a significant amount of interconnection between fundamental physics, measurement techniques, data processing, decision making, and reporting to have a significant impact on industry. NDT&E practitioners are challenged to keep up with the fast-paced evolution of materials, structures, processing, and manufacturing technologies. The development of engineered materials, complex structures and composites, and novel forming techniques require NDT&E to rapidly evolve to meet the needs of industry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New acousto-ultrasonic techniques applied to aerospace materials

The use of an NdYAG pulsed laser for generating ultrasonic waves for NDE in resin matrix composites was investigated. A study was conducted of the use of the 1.064 micron wavelength NdYAG pulsed laser with the neat, unreinforced resin as well as graphite fiber/polymer composite specimens. In the case of the neat resins it was found that, at normal incidence, about 25 percent of the laser pulse energy was reflected at the incident surface. An attenuation coefficient for the polyimide resin, PMR-15 was determined to be approximately 5.8 np/cm. It was found in energy balance studies that graphite fiber/polymer specimens attenuate the laser beam more than do neat resins. The increase absorption is in the graphite fibers. The occurrence of laser induced surface damage was also studied. For the polymer neat resin, damage appears as pit formation over a small fraction of the pulse impact area and discoloration over a larger part of the area. A damage threshold was inferred from observed damage as a function of pulse energy. The 600 F cured PMR-15 and PMR-11 exhibit about the same amount of damage for a given laser pulse energy. The damage threshold is between 0.06 and 0.07 J/sq cm.

Kautz, Harold E.↗

Characterization of the acoustic cavitation in ionic liquids in a horn-type ultrasound reactor

Most ultrasound-based processes root in empirical approaches. Because nearly all advances have been conducted in aqueous systems, there exists a paucity of information on sonoprocessing in other solvents, particularly ionic liquids (ILs). In this work, we modelled an ultrasonic horn-type sonoreactor and investigated the effects of ultrasound power, sonotrode immersion depth, and solvent’s thermodynamic properties on acoustic cavitation in nine imidazolium-based and three pyrrolidinium-based ILs. The model accounts for bubbles, acoustic impedance mismatch at interfaces, and treats the ILs as incompressible, Newtonian, and saturated with argon. Following a statistical analysis of the simulation results, we determined that viscosity and ultrasound input power are the most significant variables affecting the intensity of the acoustic pressure field (P), the volume of cavitation zones (V), and the magnitude of the maximum acoustic streaming surface velocity (u). V and u increase with the increase of ultrasound input power and the decrease in viscosity, whereas the magnitude of negative P decreases as ultrasound power and viscosity increase. Probe immersion depth positively correlates with V, but its impact on P and u is insignificant. 1-alkyl-3-methylimidazolium-based ILs yielded the largest V and the fastest acoustic jets – 0.77cm 3 and 24.4ms -1 for 1-ethyl-3-methylimidazolium chloride at 60W. 1-methyl-3-(3-sulfopropyl)-imidazolium-based ILs generated the smallest V and lowest u – 0.17cm 3 and 1.7ms -1 for 1-methyl-3-(3-sulfopropyl)-imidazolium p-toluene sulfonate at 20W. Sonochemiluminescence experiments validated the model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Thermo-Elastic Properties and Damping of U-6wt%Nb

While thermal expansion data exists for quenched (as well as aged) U-6wt%Nb, there is wide variation in the reported room temperature elastic moduli. To better understand the room temperature elastic behavior and to address the complete absence of data on the temperature dependence of the elastic moduli, room temperature and in-situ elevated temperature resonant ultrasonic spectroscopy (RUS) was performed along with x-ray diffraction (XRD) and dilatometry using a thermomechanical analyzer (TMA). An in-situ small- and wide-angle x-ray scattering (SAXS/WAXS) experiment was performed on a companion sample to help interpret the results. The room temperature polycrystalline dynamic moduli were measured to be E = 95.4 ± 4.5 GPa and G = 35.2 ± 0.2 GPa, respectively. As the temperature is raised, the stiffness slowly decreases, consistent with the empirical rule proposed by Varshni, up to the point of precipitation of the equilibrium α-U phase, which is stiffer than the martensitic phases. Homogenization theory of composites can be used to rationalize the observed response at high temperatures and after high-temperature exposures. Further, aging of the material at low temperatures (≤200°C) does not affect the linear elastic stiffness, but does impact the damping behavior which can be measured through RUS. This change in damping provides another perspective on the microstructure changes induced by low-temperature aging which also result in significant strengthening.

36 MATERIALS SCIENCE↗

Hybrid Wing Body Shielding Studies Using an Ultrasonic Configurable Fan Artificial Noise Source Generating Typical Turbofan Modes

An Ultrasonic Configurable Fan Artificial Noise Source (UCFANS) was designed, built, and tested in support of the NASA Langley Research Center's 14x22 wind tunnel test of the Hybrid Wing Body (HWB) full 3-D 5.8% scale model. The UCFANS is a 5.8% rapid prototype scale model of a high-bypass turbofan engine that can generate the tonal signature of proposed engines using artificial sources (no flow). The purpose of the test was to provide an estimate of the acoustic shielding benefits possible from mounting the engine on the upper surface of an HWB aircraft using the projected signature of the engine currently proposed for the HWB. The modal structures at the rating points were generated from inlet and exhaust nacelle configurations - a flat plate model was used as the shielding surface and vertical control surfaces with correct plan form shapes were also tested to determine their additional impact on shielding. Radiated acoustic data were acquired from a traversing linear array of 13 microphones, spanning 36 inches. Two planes perpendicular, and two planes parallel, to the axis of the nacelle were acquired from the array sweep. In each plane the linear array traversed 4 sweeps, for a total span of 168 inches acquired. The resolution of the sweep is variable, so that points closer to the model are taken at a higher resolution. Contour plots of Sound Pressure Levels, and integrated Power Levels, from nacelle alone and shielded configurations are presented in this paper; as well as the in-duct mode power levels.

Sutliff, Daniel L.↗

Hybrid Wing Body Shielding Studies Using an Ultrasonic Configurable Fan Artificial Noise Source Generating Typical Turbofan Modes

An Ultrasonic Configurable Fan Artificial Noise Source (UCFANS) was designed, built, and tested in support of the NASA Langley Research Center's 14- by 22-ft wind tunnel test of the Hybrid Wing Body (HWB) full 3-D 5.8 percent scale model. The UCFANS is a 5.8 percent rapid prototype scale model of a high-bypass turbofan engine that can generate the tonal signature of proposed engines using artificial sources (no flow). The purpose of the test was to provide an estimate of the acoustic shielding benefits possible from mounting the engine on the upper surface of an HWB aircraft using the projected signature of the engine currently proposed for the HWB. The modal structures at the rating points were generated from inlet and exhaust nacelle configurations--a flat plate model was used as the shielding surface and vertical control surfaces with correct plan form shapes were also tested to determine their additional impact on shielding. Radiated acoustic data were acquired from a traversing linear array of 13 microphones, spanning 36 in. Two planes perpendicular, and two planes parallel, to the axis of the nacelle were acquired from the array sweep. In each plane the linear array traversed four sweeps, for a total span of 168 in. acquired. The resolution of the sweep is variable, so that points closer to the model are taken at a higher resolution. Contour plots of Sound Pressure Levels, and integrated Power Levels, from nacelle alone and shielded configurations are presented in this paper; as well as the in-duct mode power levels

Sutliff, Daniel l.↗

Unsteady- and Steady-State Relative Permeability Study with X-ray and Acoustic Monitoring for CO 2 Storage in Deep Saline Aquifers

In this study, we link the multiphase flow measurements with controls of sedimentary structures (e.g., heterogeneity and anisotropy) on relative permeability to variations in ultrasonic velocities for two deep saline aquifer formations (Entrada and Bluff Sandstones) in the San Juan Basin of the Southwestern USA. The rock specimens were extracted from outcrop sites near Durango, CO, USA. They have distinct differences in grain size, cementation composition, and individual chemical amounts, despite both formations being eolian sandstones. We performed a series of unsteady- and steady-state CO 2 -brine relative permeability experiments under capillary-controlled displacement rates. Unsteady-state experiments were conducted at 71 °C and 9.65 MPa; steady-state experiments were conducted at 85 °C and 22.8 MPa and 89 °C and 24.1 MPa for the Bluff and Entrada Sandstones, respectively. During the unsteady experiments, X-ray computed tomography was used to visualize multiphase flow in porous media and quantify saturations during brine drainage under various flow rates. Scan images and saturation profiles indicate that the CO 2 distribution in the pore volume was strongly impacted by the presence of high-angle cross-laminations, heterogeneous rock structure, and direction of bedding orientation. Those factors contribute to dramatic and quick initial breakthroughs and affect the overall saturation dynamics. Steady-state relative permeability tests were conducted at net flow rates of 1 mL/min for both brine drainage and imbibition. During the experimental steps, the CO 2 fractional flow was increased and decreased for both drainage and imbibition scenarios to mimic the front when CO 2 contacts brine and behind the front when brine enters space previously occupied by CO 2 . It was found that compressional velocity decreased, while shear waves slightly increased as brine saturation decreased. The hysteresis effects for the relative permeability and acoustic velocities were distinct. Furthermore, the CO 2 /brine front stability is quantified by applying a mobility ratio approach to spot saturations at which the boundary line between fluids becomes uneven. The results presented in this work can potentially boost the quality and precision of forecasts for the CO 2 storage projects in which the vertical and horizontal core-scale heterogeneity and anisotropy impact the plume migration within host reservoirs.

carbon dioxide (CO2)↗

Stress Dependence of Ultrasonic Velocity in Unidirectional Graphite/Epoxy Composites for Longitudinal Waves Propagating Along the Direction of Stress

The first measurements of the stress induced velocity changes for propagation directions along the direction of applied stress in gr/ep composites have been presented. For propagation and stress direction perpendicular to the fiber direction, the data demonstrated a linear relation between normalized velocity shift and stress. After corrections for the delay line were made, the slope or SAC was determined and compared favorably with the expected value calculated from the previously determined nonlinear coefficients of this material. The ratio of the SAC to the elastic compliance for this direction of loading was evaluated and found to have a value similar to numerous other materials which have very different linear elastic properties. Measurements with stress and propagation along the fibers yielded unusual behavior. The curves were very nonlinear and even shifted direction at higher loads. The large scatter in the data due to bond variations made separation of material effects from bond induced artifacts impossible. Thus the SAC, R, and the remaining two unknown TOEC's could not be determined for this direction of propagation. These measurements further expand the basis of determining nonlinear elastic properties of composite materials. These properties may be useful in developing much needed NDE techniques to determine such important parameters as residual stress after cure and residual strength after impact damage. Additional study is needed to measure the nonlinear behavior in other composite materials including angle ply laminates. Also, other techniques to measure elastic nonlinearity such as harmonic generation should be applied to composites to improve the understanding of these properties and their importance.

Prosser, William H.↗

The Use of Acoustic Cavitation to Recovery High-Assay Low-Enriched Uranium (HALEU) form TRISO Fuel Particles

Recent interest in advanced nuclear reactor concepts such as small modular reactor (SMR), micro reactor or versatile test reactor (VTR) has increased the demand for high-assay, low-enriched uranium (HALEU). The sustainable management of this resource is integral to successful resurgence of nuclear energy in the United States. The High Temperature Gas-Cooled Reactor (HTGR) concept is a prime candidate for deployment of the new fleet of SMRs, and it will become very important to have a simple and cost-effective technology to recover HALEU from short-burned, defective, or off-specification TRISO fuel particles. We have attempted to harness the high energetics of sonochemistry to penetrate the TRISO fuel particles and recover HALEU via acidic leaching. While the TRISO fuel particle design is inherently “bulletproof,” (due to the silicon carbide (SiC) layer), ultrasonic irradiation may hold the key to convenient access to its valuable contents. Sonochemistry is a field of chemistry based on acoustic cavitation, which is the formation, growth, and collapse of bubbles in liquid media.1,2 The oscillating bubble formation is produced by irradiation of a liquid media with sound waves. Literature reports indicate that collapsing bubbles induced by cavitation produces intense local heating, high pressures, and short lifetimes.1 These localized hot spots reach temperatures of ˜5000 K, pressures approaching 500 atm, and heating and cooling rates exceeding 100 K/s.1 The large temperature and pressure differentials deliver high-energy heating and microscopic explosive shock waves to a liquid media or liquid/solid interface. Cavitation at the surface of a solid in solution induces a deformation in the bubble cavity upon collapse. This deformation reinforces the bubble structure and sends a fast-moving stream of liquid through the cavity at the surface with velocities greater than 100 m/s.3 These energetic impacts have demonstrated an ability to penetrate or simply destroy the SiC shell surrounding the uranium fuel kernel during prolonged exposures to the high-power acoustic waves. Some preliminary results demonstrating HALEU recovery using sonochemistry techniques will be reported.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ultrasonic/Sonic Impacting Penetrators

Ultrasonic/sonic impacting penetrators (USIPs) are recent additions to the series of apparatuses based on ultrasonic/sonic drill corers (USDCs). A USIP enables a rod probe to penetrate packed soil or another substance of similar consistency, without need to apply a large axial force that could result in buckling of the probe or in damage to some buried objects. USIPs were conceived for use in probing and analyzing soil to depths of tens of centimeters in the vicinity of buried barrels containing toxic waste, without causing rupture of the barrels. USIPs could also be used for other purposes, including, for example, searching for pipes, barrels, or other hard objects buried in soil; and detecting land mines. USDCs and other apparatuses based on USDCs have been described in numerous previous NASA Tech Briefs articles. The ones reported previously were designed, variously, for boring into, and/or acquiring samples of, rock or other hard, brittle materials of geological interest. To recapitulate: A USDC can be characterized as a lightweight, low-power, piezoelectrically driven jackhammer in which ultrasonic and sonic vibrations are generated and coupled to a tool bit. As shown in the figure, a basic USDC includes a piezoelectric stack, a backing and a horn connected to the stack, a free mass (free in the sense that it can slide axially a short distance between the horn and the shoulder of tool bit), and a tool bit, i.e., probe for USIP. The piezoelectric stack is driven at the resonance frequency of the stack/horn/backing assembly to create ultrasonic vibrations that are mechanically amplified by the horn. To prevent fracture during operation, the piezoelectric stack is held in compression by a bolt. The bouncing of the free mass between the horn and the tool bit at sonic frequencies generates hammering actions to the bit that are more effective for drilling than is the microhammering action of ultrasonic vibrations in ordinary ultrasonic drills. The hammering actions are so effective that the axial force needed to make the tool bit advance into the material of interest is much smaller than in ordinary twist drilling, ultrasonic drilling, or ordinary steady pushing.

Bao, Xiaoqi↗

Stability and Heat Transfer Characteristics of Condensing Films

The overall objective of this research is to investigate the fundamental physics of film condensation in reduced gravity. The condensation of vapor on a cool surface is important in many engineering problems,including spacecraft thermal control and also the behavior of condensate films that may form on the interior surfaces of spacecraft. To examine the effects of body force on condensing films, two different geometries have been tested in the laboratory: (1) a stabilizing gravitational body force (+1g, or condensing surface facing 'upwards') and (2) de-stabilizing gravitational body force (-1g, or 'downwards'). For each geometry, different fluid configurations are employed to help isolate the fluid mechanical and thermal mechanisms operative in condensing films. The fluid configurations are (a) a condensing film, and (b) a non-condensing film with film growth by mass addition by through the plate surface. Condensation experiments are conducted in a test cell containing a cooled copper or brass plate with an exposed diameter of 12.7 cm. The metal surface is polished to allow for double-pass shadowgraph imaging, and the test surface is instrumented with imbedded heat transfer gauges and thermocouples. Representative shadowgraph images of a condensing, unstable (-1g) n-pentane film are shown. The interfacial disturbances associated with the de-stabilizing body force leading to droplet formation and break-off can be clearly seen. The heat transfer coefficient associated with the condensing film is shown. The heat transfer coefficient is seen to initially decrease, consistent with the increased thermal resistance due to layer growth. For sufficiently long time, a steady value of heat transfer is observed, accompanied by continuous droplet formation and break-off. The non-condensing cell consists of a stack of thin stainless steel disks 10 cm in diameter mounted in a brass enclosure. The disks are perforated with a regular pattern of 361 holes each 0.25 mm in diameter. Non-condensing experiments in -1g have employed 50 cSt and 125 cSt silicone oil pumped through the perforated disks at a specified rate by a syringe micropump. The time to droplet break-off and the disturbance wavelengths appear to decrease with increasing pumping rate. The ability to reliably perform multi-point, ultrasonic measurements of the film thickness has been demonstrated. A linear array of eight transducers of 6 mm diameter (with a beam footprint of comparable size) are pulsed with a square-wave signal at a frequency of 5 MHz and a pulse duration of approximately 0.3 s. For thin films (60 m to 2-3 mm in thickness) the layer thickness is determined by frequency analysis, where the received ultrasound pulse is Fourier transformed and the spacing between the peaks in the frequency spectrum is analyzed. For thicker layers (up to at least 1 cm in thickness), time-domain analysis is performed of the received ultrasound pulses to generate directly the layer thickness. A time-trace of the film thickness at a point using a single transducer in the linear array is shown for the case of an unstable (-1g) n-pentane film. The oscillations in film thickness are evidently due to the passage and/or shedding of droplets from the cooled plate surface. The entire transducer array was used to measure the changes in film thickness resulting from the passage of gravity waves generated either by an oscillating wall or the impact of a single droplet on the free surface of a film. The enclosure in both cases was 14 cm square and the transducer spacing was 12 mm. Best results were obtained using as test fluid a mixture of 50% glycerol and 50% water with a fluid layer thickness of 3-5 mm. In both cases the measured wavelengths and wave propagation speeds using the ultrasound technique compared reasonably well with those observed by optical imaging. Additional information can be found in the original extended abstract.

Hermanson, J. C.↗

Fiber Optic Sensing Monitors Strain and Reduces Costs

In applications where stress on a structure may vary widely and have an unknown impact on integrity, a common engineering strategy has been overbuilding to ensure a sufficiently robust design. While this may be appropriate in applications where weight concerns are not paramount, space applications demand a bare minimum of mass, given astronomical per-pound launch costs. For decades, the preferred solution was the tactic of disassembly and investigation between flights. Knowing there must be a better way, Dr. Mark Froggatt, of Langley Research Center, explored alternate means of monitoring stresses and damage to the space shuttle. While a tear-it-apart-and-have-a-look strategy was effective, it was also a costly and time consuming process that risked further stresses through the very act of disassembly and reassembly. An alternate way of monitoring the condition of parts under the enormous stresses of space flight was needed. Froggatt and his colleagues at Langley built an early-warning device to provide detailed information about even minuscule cracks and deformations by etching a group of tiny lines, or grating, on a fiber optic cable five-thousandths of an inch thick with ultraviolet light. By then gluing the fiber to the side of a part, such as a fuel tank, and shining a laser beam down its length, reflected light indicated which gratings were under stress. Inferring this data from measurements in light rather than in bonded gauges saved additional weight. Various shuttle components now employ the ultrasonic dynamic vector stress sensor (UDVSS), allowing stress detection by measuring light beamed from a built-in mini-laser. By measuring changes in dynamic directional stress occurring in a material or structure, and including phase-locked loop, synchronous amplifier, and contact probe, the UDVSS proved especially useful among manufacturers of aerospace and automotive structures for stress testing and design evaluation. Engineers could ensure safety in airplanes and spaceships with a narrower, not overbuilt, margin of safety. For this development, in 1997, Discover Magazine named Froggatt a winner in the "Eighth Annual Awards for Technological Innovation" from more than 4,000 entries.

Source record↗

Temperature-dependent elastic constants of thorium dioxide probed using time-domain Brillouin scattering

Herein we report the adiabatic elastic constants of single-crystal thorium dioxide over a temperature range of 77–350 K. Time-domain Brillouin scattering, an all-optical, non-contact picosecond ultrasonic technique, is used to generate and detect coherent acoustic phonons that propagate in the bulk perpendicular to the surface of the crystal. These coherent acoustic lattice vibrations have been monitored in two hydrothermally grown single-crystal thorium dioxide samples along the (100) and (311) crystallographic directions. The three independent elastic constants of the cubic crystal (C 11 , C 12 , and C 44 ) are determined from the measured bulk acoustic velocities. The longitudinal wave along the (100) orientation provided a direct measurement of C 11 . Measurement of C 44 and C 12 was achieved by enhancing the intensity of quasi-shear mode in a (311) oriented crystal by adjusting the polarization angle relative to the crystal axes. We find the magnitude of softening of the three elastic constants to be ~2.5% over the measured temperature range. Good agreement is found between the measured elastic constants with previously reported values at room temperature, and between the measured temperature-dependent bulk modulus with calculated values. We find that semi-empirical models capturing lattice anharmonicity adequately reproduce the observed trend. We also determine the acoustic Grüneisen anharmonicity parameter from the experimentally derived temperature-dependent bulk modulus and previously reported temperature-dependent values of volumetric thermal expansion coefficient and heat capacity. This work presents measurements of the temperature-dependent elasticity in single-crystal thorium dioxide at cryogenic temperature and provides a basis for testing ab initio theoretical models and evaluating the impact of anharmonicity on thermophysical properties.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Genesis Concentrator Target Particle Contamination Mapping and Material Identification

The majority of surface particles were found to be < 5 microns in diameter with increasing numbers close to the optical resolution limit of 0.3 microns. Acceleration grid EDS results show that the majority of materials appear to be from the SRC shell and SLA materials which include carbon-carbon fibers and Si-rich microspheres in a possible silicone binder. Other major debris material from the SRC included white paint, kapton, collector array fragments, and Al. Image analysis also revealed that SRC materials were also found mixed with the Utah mud and salt deposits. The EDS analysis of the acceleration grid showed that particles < 1 m where generally carbon based particles. Chemical cleaning techniques with Xylene and HF in an ultrasonic bath are currently being investigated for removal of small particles by the Genesis science team as well as ultra-pure water megasonic cleaning by the JSC team [4]. Removal of organic contamination from target materials is also being investigated by the science team with the use of UV-ozone cleaning devices at JSC and Open University [5]. In preparation for solar wind oxygen analyses at UCLA and Open University [1, 2], surface particle contamination on three Genesis concentrator targets was closely examined to evaluate cleaning strategies. Two silicon carbide (Genesis sample # 60001 and 60003) and one chemical vapor deposited (CVD) 13C concentrator target (60002) were imaged and mosaic mapped with optical microscopes. The resulting full target mosaic images and particle feature maps were subsequently compared with non-flight, but flight-like, concentrator targets and sample return capsule (SRC) materials. Contamination found on the flown concentrator acceleration grid was further examined using a scanning electron microscope (SEM). Energy dispersive X-ray spectroscopy (EDS) for particle identification was subsequently compared with the optical images from the flown targets. Figure 1 show that all three targets imaged in this report are fully intact and do not show any signs of material fractures. However, previous ellipsometry results and overview imaging of both flown SiC targets show a solar wind irradiation gradient from the center focal point to the outer edge [3]. In addition, due to the hard landing, each target has experienced varying degrees of impacts, scratches, and particle debris from the spacecraft and Utah impact site.

Calaway, Michael J.↗

Alternative, Green Processes for the Precision Cleaning of Aerospace Hardware

Precision cleaning is necessary to ensure the proper functioning of aerospace hardware, particularly those systems that come in contact with liquid oxygen or hypergolic fuels. Components that have not been cleaned to the appropriate levels may experience problems ranging from impaired performance to catastrophic failure. Traditionally, this has been achieved using various halogenated solvents. However, as information on the toxicological and/or environmental impacts of each came to light, they were subsequently regulated out of use. The solvent currently used in Kennedy Space Center (KSC) precision cleaning operations is Vertrel MCA. Environmental sampling at KSC indicates that continued use of this or similar solvents may lead to high remediation costs that must be borne by the Program for years to come. In response to this problem, the Green Solvents Project seeks to develop state-of-the-art, green technologies designed to meet KSCs precision cleaning needs.Initially, 23 solvents were identified as potential replacements for the current Vertrel MCA-based process. Highly halogenated solvents were deliberately omitted since historical precedents indicate that as the long-term consequences of these solvents become known, they will eventually be regulated out of practical use, often with significant financial burdens for the user. Three solvent-less cleaning processes (plasma, supercritical carbon dioxide, and carbon dioxide snow) were also chosen since they produce essentially no waste stream. Next, experimental and analytical procedures were developed to compare the relative effectiveness of these solvents and technologies to the current KSC standard of Vertrel MCA. Individually numbered Swagelok fittings were used to represent the hardware in the cleaning process. First, the fittings were cleaned using Vertrel MCA in order to determine their true cleaned mass. Next, the fittings were dipped into stock solutions of five commonly encountered contaminants and were weighed again showing typical contaminant deposition levels of approximately 0.00300g per part. They were then cleaned by the solvent or process being tested and then weighed a third time which allowed for the calculation of the cleaning efficiency of the test solvent or process.Based on preliminary experiments, five solvents (ethanol, isopropanol, acetone, ethyl acetate, and tert-butyl acetate) were down selected for further testing. When coupled with ultrasonic agitation, these solvents removed hydrocarbon contaminants as well as Vertrel MCA and showed improved removal of perfluorinated greases. Supercritical carbon dioxide did an excellent job dissolving each of the five contaminants but did a poor job of removing Teflon particles found in the perfluorinated greases. Plasma cleaning efficiency was found to be dependent on which supply gas was used, exposure time, and gas pressure. Under optimized conditions it was found that breathing air, energized to the plasma phase, was able to remove nearly 100% of the contamination.These findings indicate that alternative cleaning methods are indeed able to achieve precision levels of cleanliness. Currently, our team is working with a commercial cleaning company to get independent verification of our results. We are also evaluating the technical and financial aspects of scaling these processes to a size capable of supporting the future cleaning needs of KSC.

Vertrel MCA↗

Development of a Robust Reference Electrode in Aggressive Chemical and Radiation Environments in the Hanford Waste Tanks

The Hanford site stores more than 200 million liters of radioactive and chemically hazardous wastes from the production of weapons materials. The wastes are stored in 177 underground carbon-steel storage tanks, separated between 149 single shell tanks (SSTs) and 28 double shell tanks (DSTs). The DSTs provide critical retrieval and interim storage before the waste is vitrified in the Waste Treatment and Isolation Plant (WTP). The tanks will need to remain in-service far beyond the initial 40-year design life, and effective corrosion control practices must remain in force to extend the tanks’ lifespans. This effort includes direct measurements of corrosion rate (e.g., ultrasonic measurements and corrosion coupons) and electrochemical processes (e.g., linear polarization measurements and open circuit potential measurements). The Hanford site began monitoring the corrosion potential in select DSTs in 2008. Of the 45 reference electrodes that have been installed, 29 have failed and 6 others provided unreliable results. DOE-EM is supporting a 3-year program to develop a chemical and radiation resistant reference electrode for application in the Hanford tanks. The first year of the program focused on understanding the failure mechanism for the reference electrodes and identification of candidate construction materials that would mitigate degradation of the electrodes in the waste environment. During the second year of the program, the objectives were to: 1) test candidate materials under simulated waste conditions, 2) design components that will extend the service life of the electrode, 3) fabricate materials for prototype reference electrodes, and 4) assemble prototype reference electrodes for accelerated testing. The reference electrode is constructed of four principal parts: 1) junction, 2) casing, 3) inner chamber backfill materials, and 4) the sensing wire. Principally, improvements of the junction, casing, and inner chamber backfill materials are being pursued. The junction material at the interface between the waste and the inner chamber of the reference electrode was identified as a critical component in the failure of the reference electrodes. Nine candidate replacement junction materials were tested under simulated waste conditions to evaluate permeation rate. These materials included a variety of polymeric and ceramic materials, some of which were 3-D printed. Thus far, porous polyvinylidene fluoride materials have performed satisfactorily and are being considered for prototype development. The commercial electrode casing materials in general have performed well. Additionally, 3-D printing of chemically and mechanically stable materials is being investigated as a means for further improvement in fabrication consistency. SRNL has also investigated altering the reference electrode design to extend the service life. The new design of the interior of the reference electrode casing creates a longer, more tortuous path between the junction material and the electrode sensing wire. A finite element model was used to optimize the design without adversely impacting the circuit resistance of the electrode during the measurements, thus preserving the measurement accuracy while enhancing the service life. The inner chamber back fill materials are also critical to the performance of the reference electrode. Materials that are resistant to intruding tank waste and provide a conductive path to the sensing wire were investigated. Gel and powder materials that are interspersed with a conductive chloride bearing material were tested for their influence on diffusion and electrode resistance. All the investigated materials and components will be assembled, with collaboration from commercial vendors, to fabricate the initial prototypes. Accelerated testing of the prototypes will be initiated in Year 2 of the program and will be completed in Year 3. A recommendation on the materials of construction and the design of the new robust reference electrode will be presented to the Hanford tank farm facility.

Sykes, Kiana [Savannah River National Laboratory (↗

Cathodic Protection Modeling for Hanford Underground Double-Shell Tank Farms

Hanford stores millions of gallons of radioactive and chemically hazardous waste from the production of weapon materials in tank farms consisting of underground carbon-steel storage tanks surrounded by reinforced concrete. Six of these Hanford tank farms use double-shell storage tanks (DSTs). The DST farms were constructed from 1968 to 1986 with a planned 40–50 year design life, so some are already operating beyond their initial life expectancy. Ultrasonic testing (UT) has indicated significant thinning on the bottom of the secondary (outer) liner of these tanks, believed to arise from groundwater intrusion driving concrete side corrosion. There is no direct access to the steel/concrete interface between the tank and the concrete pad, making it difficult to apply a chemical-based mitigation strategy or to conduct repairs, but cathodic protection (CP) is a possible method to inhibit further concrete-side corrosion. Hanford already uses CP to protect below grade steel piping within the tank farms and connected to the tanks, but this system was not designed to protect the tank bottoms. CP design must account for the structures surrounding the DSTs, including the steel reinforcing bars (rebar) within the concrete pad and vault, various process lines, and the existing CP system. In this study, finite element analysis (FEA) modeling was carried out to simulate CP protection of 1) a single tank and CP anode to develop options for modeling the rebar and to compare to a simpler circuit model and 2) the entire Hanford AN tank farm as a representative example consisting of seven tanks, associated piping, and both existing and new CP anodes. Both circuit and FEA models predict that significant protective current could be delivered to the bottoms of the tanks with the addition of tank-protection anodes below the depth of the tanks. Simulations with only the existing pipe-protection anodes active confirmed that only a very small current to the tank bottoms is predicted under present conditions. Multiple simplified representations of the dome and wall rebar were tested to reduce the computational complexity of the tank-farm simulations, resulting in modeling the rebar as edge elements with a prescribed effective circumference that matches the real rebar surface area. The geometry of the rebar is also simplified into horizontal hoops around the tank walls and radial rebar over the dome with increased effective circumference to retain the target surface area. This simplification was found to greatly reduce the complexity and solution time of the models without large changes in current distributions, especially to the tank bottom. A range of values were tested for model parameters such as soil and concrete resistivities and polarization resistance to investigate their impact on the current and electric potential distributions. Depending on the parameters used, FEA simulations predict some risk of overprotection, particularly on the piping system; since overprotection can also lead to surface damage associated with hydrogen gas generation at the interface (e.g. hydrogen embrittlement or damage to coatings), this needs to be considered when refining the design of the new CP system. Comparison between the FEA models and the circuit model representation demonstrated that the circuit model could not match the predicted FEA current distribution, even when using the exact same surface areas. This discrepancy appeared to be at least partly attributable to the impact of the relative positions of the tank components and anodes to each other and to the ground surface. The FEA model accounts for the relative positions since it solves the governing equations in three dimensions, but the circuit model cannot account for the positioning. In particular, the circuit model underpredicts the current to the tank bottom and overpredicts the current to the dome compared to FEA for the baseline geometry. The FEA models omitted the electrically isolated rebar in the bottom concrete slab. However, a circuit based stray current model estimated that only 2.1% of the total current through the slab would stray into the rebar, corresponding to ~0.21 A for a target current density of 2 mA/ft2 to the tank bottom. The estimated corrosion driven by this amount of stray current is predicted to yield a lifetime of >400 years for the minimum rebar diameter, assuming an acceptable cross-section area loss of 10%.

d'Entremont, Anna [Savannah River National Laborat↗

Current Status of Martian Moons eXploration (MMX) Contamination Control and Curation Activity

Martian Moons eXploration (MMX) is a sample return mission from the Martian moon Phobos. The MMX spacecraft is scheduled to launch in 2026 and return to Earth in 2031. The main science goals of MMX are “to reveal the origin of the Martian moons and make progress in the understanding of planetary system formation and material transport in the solar system, and to observe processes that impact the circumplanetary and surface environments of Mars”. MMX has two sampling systems: coring (C)-sampler and pneumatic (P)-sampler and plans to bring back >10 g of Phobos sample. The retuned sample in the sample capsule will be transferred to the curation facility in ISAS/JAXA for sample curation and subsequent sample analysis. Contamination control of the sample return mission requires special care to prevent terrestrial contamination to the spacecraft, which would ruin the scientific value of the returned sample. Retaining the pristineness of the retuned sample is an important task of the MMX Curation and Sampler Science teams. The basis of the contamination control is (1) to minimize and understand the nature and amount of contaminants, (2) to perform contamination assessment and evaluate the effect of contaminants in the spacecraft on the retuned sample, (3) to employ a contamination knowledge (CK) material coupon in the spacecraft to identify the contaminants in the returned samples. In the MMX contamination control plan, the allowable contamination level for each contaminant is carefully defined. They are mostly set to be 1/1000 of the expected amount of each material in the returned sample and are divided into two main categories: organic and inorganic. The allowable atmospheric leakage rate to the sample container is also defined. The allowable contamination level of the organic materials is based on the composition of carbonaceous chondrites. The target contaminants are amino acids, aliphatic and aromatic hydrocarbons, carboxylic acids, etc. In case of the inorganic materials, the target contaminants are important elements to permit distinguishing the origin of the Martian moon by nucleosynthetic isotope anomalies (Cr, Ti, and Mo) and to reveal the evolution of the Martian moon by chronology (Hf, W, U, Pb, Rb, Sr, Sm, and Nd). The key instrument of contamination control in the sample return mission is the sampler system. The C-sampler has been developed by JAXA and the P-sampler was provided by Honeybee/NASA. In MMX, materials used in the two samplers (C- and P- sampler) were carefully selected to avoid potential contamination from the design stage of the system. The individual parts of the C-sampler FM (Flight Model) were thoroughly cleaned at the curation facility in ISAS/JAXA by the full-course cleaning procedure, which is an ultrasonic cleaning with organic solvents and ultrapure water in several steps. The equivalent level of cleaning was also carried out on the P-Samper FM as well by Honeybee Robotics in the USA. Now, MMX is in the critical phase for contamination control called ATLO: Assembly, Test, and Launch Operations. During the ATLO phase, sampler FM is constantly purged with nitrogen gas and maintained at positive pressure to prevent environmental contamination. The surrounding environments of the sampler FM are also simultaneously monitored using the CK Monitoring Coupon Set, which consists of several witness materials such as a glass petri dish, sapphire glass disk, and carbon adhesive tape (Figure 1). The detailed environmental assessment of each clean room used for the assembly and test of the sampler FM has also been conducted. This assessment includes microbial analysis, which was performed for OSIRIS-REx. Regarding the sample recovery and sample curation, we have started the designing of Sample Container Disassembling Instrument for the sample recovery from the sample container and the MMX curation chamber for sample curation. The curation protocol for the Phobos returned sample has also been discussed by the MMX Sample Analysis Working Team (SAWT). The MMX curation protocol consists of three phases: (1) quick analysis, (2) pre-basic characterization, and (3) basic characterization. (1) is extraction of the sample gas from the sample container and analysis by mass spectrometry, (2) is observation in bulk level, and (3) is observation in grain level and allocation of the sample aliquots. In parallel with the curation protocol, the returned sample undergoes preliminary examination for scientific investigations to achieve science goals. In addition, the CK witness plates made of sapphire glass are on board the sampler system. The CK witness plates will be recovered from the sampler system and analyzed by SAWT for the assessment of in-flight contamination.

Haruna Sugahara↗