Search NASA⌕ Search

SEARCH · Search NASA

Results for “uniform methods project”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Improving Estimation of Ground Casualty Risk From Reentering Space Objects

A recent improvement to the long-term estimation of ground casualties from reentering space debris is the further refinement and update to the human population distribution. Previous human population distributions were based on global totals with simple scaling factors for future years, or a coarse grid of population counts in a subset of the world's countries, each cell having its own projected growth rate. The newest population model includes a 5-fold refinement in both latitude and longitude resolution. All areas along a single latitude are combined to form a global population distribution as a function of latitude, creating a more accurate population estimation based on non-uniform growth at the country and area levels. Previous risk probability calculations used simplifying assumptions that did not account for the ellipsoidal nature of the Earth. The new method uses first, a simple analytical method to estimate the amount of time spent above each latitude band for a debris object with a given orbit inclination and second, a more complex numerical method that incorporates the effects of a non-spherical Earth. These new results are compared with the prior models to assess the magnitude of the effects on reentry casualty risk.

Ostrom, Chris L.↗

Improving Estimation of Ground Casualty Risk from Reentering Space Objects

A recent improvement to the long-term estimation of ground casualties from reentering space debris is the further refinement and update to the human population distribution. Previous human population distributions were based on global totals with simple scaling factors for future years, or a coarse grid of population counts in a subset of the world's countries, each cell having its own projected growth rate. The newest population model includes a 5-fold refinement in both latitude and longitude resolution. All areas along a single latitude are combined to form a global population distribution as a function of latitude, creating a more accurate population estimation based on non-uniform growth at the country and area levels. Previous risk probability calculations used simplifying assumptions that did not account for the ellipsoidal nature of the earth. The new method uses first, a simple analytical method to estimate the amount of time spent above each latitude band for a debris object with a given orbit inclination, and second, a more complex numerical method that incorporates the effects of a non-spherical Earth. These new results are compared with the prior models to assess the magnitude of the effects on reentry casualty risk.

Ostrom, C.↗

Metallic Low-Level Waste (LLW) Handling Options: An Optimal Life cycle-Based Approach for North American Operations - 19413

Daily activities associated with nuclear power plant operations produce large volumes of low-level contaminated waste. During operation, a small percentage of this low-level waste is metallic (< 1% by volume). However, this figure increases materially when a facility is finally decommissioned, with approximately 1000 m{sup 3} of contaminated metal waste generated for every 1 GW decommissioned (13% by volume). With global nuclear decommissioning efforts expected to increase until 2050, the amount of low-level metallic waste generated is expected to increase the global inventory by over an order of magnitude. The high cost of conventional surface storage and burial of radioactive metal, coupled with the projected increase in low-level metallic waste volumes provides strong incentive to identify cost-effective waste management solutions. Surface decontamination and thermal methods are proven options for decontaminating low-level metallic waste. Surface decontamination processes include chemical, electrochemical, or mechanical methods, which are used to remove contamination from exposed layers of metal. Surface decontamination is most effective when metal has low levels of activity localized on the outer layers. When the activity is more uniformly distributed in the metal (or the geometry is complex), alternative methods such as thermal decontamination are required. In the thermal decontamination process, contaminated scrap metal is melted in a furnace and held in a molten state for a period of time while the radioactive material is separated out through gravity. Radioactive material reports to slag which is handled separately, or to the exhaust which is handled using conventional gas handling technologies. Thermal methods of decontamination involving metal melting present an opportunity to reduce long-term storage cost with a reduction in waste volume, along with the opportunity to reuse the decontaminated metal. Methods for dealing with metallic low-level waste from nuclear facilities vary extensively across the globe. The approach employed at any given site may be set by a host of factors ranging from regulatory influence, public perception, local economics, available geology for underground storage and often, precedent established long ago by early operations. This paper examines several low-level metallic waste handling options including techniques for surface decontamination and metal melting, as well as a combination of both. The various methods are categorized according to their suitability for waste characterization and local/global installations. The effectiveness of each option is benchmarked against a range of criteria, including capital and operating costs, environmental impact, overall sustainability and risk management issues. The overall objective of this paper is to develop a methodology for determining the most beneficial low-level metallic waste management strategy for a facility once the quantity, type and nature of the waste is established on a long-term basis. It is the authors' hope that the methodology can be used as a tool to test a facility's current plans (which are primarily focused on long-term storage) and identify areas for optimization with an emphasis on overall cost and environmental footprint reduction. The trend towards long term planning to handle large amounts of contaminated metal, along with obtaining a social license to implement a sustainable waste management solution, are key decision-making variables that will be discussed in relation to the LLW handling options presented in this paper. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Using flow information to support 3D vessel reconstruction from rotational angiography

For the assessment of cerebrovascular diseases, it is beneficial to obtain three-dimensional (3D) morphologic and hemodynamic information about the vessel system. Rotational angiography is routinely used to image the 3D vascular geometry and we have shown previously that rotational subtraction angiography has the potential to also give quantitative information about blood flow. Flow information can be determined when the angiographic sequence shows inflow and possibly outflow of contrast agent. However, a standard volume reconstruction assumes that the vessel tree is uniformly filled with contrast agent during the whole acquisition. If this is not the case, the reconstruction exhibits artifacts. Here, we show how flow information can be used to support the reconstruction of the 3D vessel centerline and radii in this case. Our method uses the fast marching algorithm to determine the order in which voxels are analyzed. For every voxel, the rotational time intensity curve (R-TIC) is determined from the image intensities at the projection points of the current voxel. Next, the bolus arrival time of the contrast agent at the voxel is estimated from the R-TIC. Then, a measure of the intensity and duration of the enhancement is determined, from which a speed value is calculated that steers the propagation of the fast marching algorithm. The results of the fast marching algorithm are used to determine the 3D centerline by backtracking. The 3D radius is reconstructed from 2D radius estimates on the projection images. The proposed method was tested on computer simulated rotational angiography sequences with systematically varied x-ray acquisition, blood flow, and contrast agent injection parameters and on datasets from an experimental setup using an anthropomorphic cerebrovascular phantom. For the computer simulation, the mean absolute error of the 3D centerline and 3D radius estimation was 0.42 and 0.25 mm, respectively. For the experimental datasets, the mean absolute error of the 3D centerline was 0.45 mm. Under pulsatile and nonpulsatile conditions, flow information can be used to enable a 3D vessel reconstruction from rotational angiography with inflow and possibly outflow of contrast agent. We found that the most important parameter for the quality of the reconstruction of centerline and radii is the range through which the x-ray system rotates in the time span of the injection. Good results were obtained if this range was at least 135 deg. . As a standard c-arm can rotate 205 deg., typically one third of the acquisition can show inflow or outflow of contrast agent, which is required for the quantification of blood flow from rotational angiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Beam steering characteristics of highly directive photoconductive dipole phased array antenna for terahertz imaging application

In this paper, the beam-steering characteristics of photoconductive dipole phased array antenna configuration at 1.95 THz is presented. The proposed array antenna configuration with frequency selective surface favourably improves its gain and directivity which is useful to upsurge the imaging capabilities to address the deliberations such as limited depth-of-field (DoF) and size-weight-and-power of the THz source for imaging applications. These are important considerations for applications like stand-off imaging and surveillance of moving targets where the high angular resolution as well as extended DoF are the important parameters for successful detection of concealed explosives. The projected planar profile and compact highly directive (2×2) small-gap photoconductive dipole phased array antenna can be castoff for the exposure of concealed explosives such as RDX, TNT, and HMX which illustrate their substantial spectral absorption fingerprints in terahertz (1.4–2.2 THz) regime of the spectrum. A simple method of beam-steering has been explored based on phase controlled optical excitation of highly directive small-gap photoconductive dipole array antenna. Further, the effects of uniform progressive phase shift on the beam-steering of uniform linear array (along x-axis) as well as planar array (x-axis and y-axis) is investigated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scanned Carbon Pencil Beams for Tumor Therapy

At GSI a fully active beam application has been developed for tumor therapy with carbon ions. In this so-called rasterscan system the tumor volume is typically split into {approx}60 slices of iso-energies taken from a list of 252 energies ranging from {approx}90-430 MeV/u(range: 1.8-30.7 cm). The energies can be combined with variable beam diameters and intensities. For each iso-energy slice beam is requested from the synchrotron and delivered as a narrow pencil beam (beam's full width at half maximum 3-10 mm). For lateral target coverage this pencil beam is deflected to several hundreds of grid positions per iso-energy slice by orthogonal dipole magnets. At each grid position an optimized number of particles is deposited intensity-controlled, i.e. ionization chambers monitor the dose deposition and trigger deflection to the next grid position once the required dose level is achieved. This method allows intensity-modulated treatment fields necessary to deposit a uniform biological effective dose. Additionally, it allows for simultaneous optimization of multiple fields that allow better sparing of organs at risk partially or fully surrounded by the tumor. Scanned beam delivery facilitates target conformal and homogeneous dose delivery for stationary targets. For tumors located in the head and neck as well as tumors in the pelvic region very promising results were achieved in the carbon therapy pilot project started at GSI in 1993. A comparable project is conducted at Paul-Scherrer-Institut (PSI) in Switzerland with a scanned proton beam. One of the current research topics is the treatment of moving targets such as lung tumors. Scanned beam delivery requires but also offers possibilities to conformably irradiate moving target sites.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Wind Tunnel Model of the Turner-Fairbank Highway Research Center Aerodynamics Laboratory [TFHRC Project Report]

The computational fluid dynamics (CFD) and computational structural mechanics (CSM) focus areas at Argonne’s Transportation Research and Analysis Computing Center (TRACC) initiated a project to support and compliment the experimental programs at the Turner-Fairbank Highway Research Center (TFHRC) with high performance computing based analysis capabilities in August 2010. The project was established with a new interagency agreement between the Department of Energy and the Department of Transportation to provide collaborative research, development, and benchmarking of advanced three-dimensional computational mechanics analysis methods to the aerodynamics and hydraulics laboratories at TFHRC for a period of five years, beginning in October 2010. The analysis methods employ well benchmarked and supported commercial computational mechanics software. Computational mechanics encompasses the areas of Computational Fluid Dynamics (CFD), Computational Wind Engineering (CWE), Computational Structural Mechanics (CSM), and Computational Multiphysics Mechanics (CMM) applied in Fluid-Structure Interaction (FSI) problems. This report documents one of the tasks in this project. In this task, a detailed CFD model of the wind tunnel laboratory at TFHRC was built and tested to provide a means to assess the air flow uniformity provided by the tunnel to the test zone and assess room geometry effects. Considerable effort went into the construction and testing of the model and various submodels, such as the screens in the wind tunnel. The model is available for use in further studies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cold Sintered Ceramics and Cements for Part Encapsulation

In this project, ceramic encapsulation materials were studied for high temperature (>~°500 C) applications where typical polymer encapsulants are unstable. A new low temperature (<~°200 C) method of processing ceramics, the cold sintering process was examined. Additionally, commercially available high temperature ceramic cements were investigated. In both cases, the mechanical strengths of available materials are less than desired (i.e., desired strengths similar to Si 3 N 4 ), limiting applicability. Composite designs to increase mechanical strength are suggested. Additionally, non-uniformities in stresses and densification while embedding alumina sheets in encapsulants via cold sintering using uni-axial pressing led to fracture of sheets, and an alternative iso-static based approach is recommended for future studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advanced electrode manufacturing to enable low cost PEM electrolysis

A critical challenge for the implementation of proton exchange membrane (PEM)-based water electrolyzers for the H2@Scale vision is the capital cost, which is largely driven by related factors of overdesign and highly manual legacy manufacturing methods. Typical electrolyzer cells have an order of magnitude higher membrane thickness and catalyst loading vs. fuel cells, in part because the manufacturing methods being used are not capable of producing uniform and reliable electrodes on thin membranes with low loading. Advanced electrode manufacturing is therefore the key enabler to reduce the cost of the electrolyzer stack, particularly roll-to-roll (R2R) manufacturing of catalyst coated layers (CCLs) and catalyst coated membranes (CCMs). The electrolyzer manufacturing process still relies on traditional sheet-to-sheet (S2S) processes, which requires intensive labor to make parts to meet the specification requirements. This project leverages fuel cell expertise (GM) with Proton’s knowledge of electrolyzer components to develop the electrocatalyst ink formulations and coating processes using slot die (ORNL) and gravure (NREL) coatings, with proof of concept at the pilot-scale (Kodak).

08 HYDROGEN↗

Development of a Woven-Grid Quasi-Bipolar Battery

This report describes an analytical and experimental investigation of AeroVironment's Quasi-Bipolar battery concept. The modelling/battery design part of the study demonstrates that there is a trade-off between thermal and specified electrical performance. Even so, quasi-bipolar batteries can be designed, with ten times better thermal uniformity, that meet or exceed current state-of-the-art hybrid-electric vehicle battery pack performance, even using the same active materials. The thermal uniformity, power, and energy for these quasi-bipolar battery packs is projected to be very good. The experimental part of the investigation demonstrates the concept of the quasi-bipolar plate applied to a lead foil current collector wrapping around two sides of an inexpensive plastic film core. Approximately 50 quasi-biplate samples were fabricated using a hot laminating press. Hot lamination with "texture" between the plastic and lead shows some promise as a low cost method for fabricating the plates. Five of these plates were assembled into two cells plus one two-cell battery. Data from these test cells were compared with existing data for similar true bipolar batteries. The positive side of the plates exhibited corrosion where not protected by the active material.

Tokumaru, P.↗

Accuracy and stability in incompressible SPH (ISPH) based on the projection method and a new approach

The stability and accuracy of three methods which enforce either a divergence-free velocity field, density invariance, or their combination are tested here through the standard Taylor-Green and spin-down vortex problems. While various approaches to incompressible SPH (ISPH) have been proposed in the past decade, the present paper is restricted to the projection method for the pressure and velocity coupling. It is shown that the divergence-free ISPH method cannot maintain stability in certain situations although it is accurate before instability sets in. The density-invariant ISPH method is stable but inaccurate with random-noise like disturbances. The combined ISPH, combining advantages in divergence-free ISPH and density-invariant ISPH, can maintain accuracy and stability although at a higher computational cost. Redistribution of particles on a fixed uniform mesh is also shown to be effective but the attraction of a mesh-free method is lost. A new divergence-free ISPH approach is proposed here which maintains accuracy and stability while remaining mesh free without increasing computational cost by slightly shifting particles away from streamlines, although the necessary interpolation of hydrodynamic characteristics means the formulation ceases to be strictly conservative. This avoids the highly anisotropic particle spacing which eventually triggers instability. Importantly pressure fields are free from spurious oscillations, up to the highest Reynolds numbers tested.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantitative Global Heat Transfer in a Mach-6 Quiet Tunnel

This project developed quantitative methods for obtaining heat transfer from temperature sensitive paint (TSP) measurements in the Mach-6 quiet tunnel at Purdue, which is a Ludwieg tube with a downstream valve, moderately-short flow duration and low levels of heat transfer. Previous difficulties with inferring heat transfer from TSP in the Mach-6 quiet tunnel were traced to (1) the large transient heat transfer that occurs during the unusually long tunnel startup and shutdown, (2) the non-uniform thickness of the insulating coating, (3) inconsistencies and imperfections in the painting process and (4) the low levels of heat transfer observed on slender models at typical stagnation temperatures near 430K. Repeated measurements were conducted on 7 degree-half-angle sharp circular cones at zero angle of attack in order to evaluate the techniques, isolate the problems and identify solutions. An attempt at developing a two-color TSP method is also summarized.

Sullivan, John P.↗

The effect of averaging adjacent planes for artifact reduction in matrix inversion tomosynthesis

Purpose: Matrix inversion tomosynthesis (MITS) uses linear systems theory and knowledge of the imaging geometry to remove tomographic blur that is present in conventional backprojection tomosynthesis reconstructions, leaving in-plane detail rendered clearly. The use of partial-pixel interpolation during the backprojection process introduces imprecision in the MITS modeling of tomographic blur, and creates low-contrast artifacts in some MITS planes. This paper examines the use of MITS slabs, created by averaging several adjacent MITS planes, as a method for suppressing partial-pixel artifacts. Methods: Human chest tomosynthesis projection data, acquired as part of an IRB-approved pilot study, were used to generate MITS planes, three-plane MITS slabs (MITSa3), five-plane MITS slabs (MITSa5), and seven-plane MITS slabs (MITSa7). These were qualitatively examined for partial-pixel artifacts and the visibility of normal and abnormal anatomy. Additionally, small (5 mm) subtle pulmonary nodules were simulated and digitally superimposed upon human chest tomosynthesis projection images, and their visibility was qualitatively assessed in the different reconstruction techniques. Simulated images of a thin wire were used to generate modulation transfer function (MTF) and slice-sensitivity profile curves for the different MITS and MITS slab techniques, and these were examined for indications of partial-pixel artifacts and frequency response uniformity. Finally, mean-subtracted, exposure-normalized noise power spectra (ENNPS) estimates were computed and compared for MITS and MITS slab reconstructions, generated from 10 sets of tomosynthesis projection data of an acrylic slab. The simulated in-plane MTF response of each technique was also combined with the square root of the ENNPS estimate to yield stochastic signal-to-noise ratio (SNR) information about the different reconstruction techniques. Results: For scan angles of 20 Degree-Sign and 5 mm plane separation, seven MITS planes must be averaged to sufficiently remove partial-pixel artifacts. MITSa7 does appear to subtly reduce the contrast of high-frequency 'edge' information, but the removal of partial-pixel artifacts makes the appearance of low-contrast, fine-detail anatomy even more conspicuous in MITSa7 slices. MITSa7 also appears to render simulated subtle 5 mm pulmonary nodules with greater visibility than MITS alone, in both the open lung and regions overlying the mediastinum. Finally, the MITSa7 technique reduces stochastic image variance, though the in-plane stochastic SNR (for very thin objects which do not span multiple MITS planes) is only improved at spatial frequencies between 0.05 and 0.20 cycles/mm. Conclusions: The MITSa7 method is an improvement over traditional single-plane MITS for thoracic imaging and the pulmonary nodule detection task, and thus the authors plan to use the MITSa7 approach for all future MITS research at the authors' institution.

60 APPLIED LIFE SCIENCES↗

Incorporation of treatment plan spatial and temporal dose patterns into a prostate intrafractional motion management strategy

Purpose: Periodic MV/KV radiographs taken during volumetric modulated arc therapy (VMAT) for hypofractionated treatment provide guidance in intrafractional motion management. The choice of imaging frequency and timing are key components in delivering the desired dose while reducing associated overhead such as imaging dose, preparation, and processing time. In this project the authors propose a paradigm with imaging timing and frequency based on the spatial and temporal dose patterns of the treatment plan. Methods: A number of control points are used in treatment planning to model VMAT delivery. For each control point, the sensitivity of individual target or organ-at-risk dose to motion can be calculated as the summation of dose degradations given the organ displacements along a number of possible motion directions. Instead of acquiring radiographs at uniform time intervals, MV/KV image pairs are acquired indexed to motion sensitivity. Five prostate patients treated via hypofractionated VMAT are included in this study. Intrafractional prostate motion traces from the database of an electromagnetic tracking system are used to retrospectively simulate the VMAT delivery and motion management. During VMAT delivery simulation patient position is corrected based on the radiographic findings via couch movement if target deviation violates a patient-specific 3D threshold. The violation rate calculated as the percentage of traces failing the clinical dose objectives after motion correction is used to evaluate the efficacy of this approach. Results: Imaging indexed to a 10 s equitime interval and correcting patient position accordingly reduces the violation rate to 19.5% with intervention from 44.5% without intervention. Imaging indexed to the motion sensitivity further reduces the violation rate to 12.1% with the same number of images. To achieve the same 5% violation rate, the imaging incidence can be reduced by 40% by imaging indexed to motion sensitivity instead of time. Conclusions: The simulation results suggest that image scheduling according to the characteristics of the treatment plan can improve the efficiency of intrafractional motion management. Using such a technique, the accuracy of delivered dose during image-guided hypofractionated VMAT treatment can be improved.

60 APPLIED LIFE SCIENCES↗

A Geostatistical Study in Support of CO 2 Storage in Deep Saline Aquifers of the Shenhua CCS Project, Ordos Basin, China

The Shenhua Carbon Capture and Storage (CCS) project at the Shenbei Slope injection site in North Yulin is the first 100,000 ton-per-year scale CCS pilot project in China with an injection operation lasting nearly 3 years. In this study, we investigate various geostatistical methods and their impact on the respective geologic models on which simulation is performed to understand the phenomena observed during 3 years of Shenhua CCS operations. Although there was a brief period of wellhead pressure increase at the injection well, it unexpectedly dropped for most of the time. Another interesting observation showed that the majority of CO 2 gas injection was received by the topmost sandstone Liujiagou formation instead of the basement limestone Majiagou formation, which was predicted to have much more injectivity and storage capacity. Based on the current geostatistical methods and available data, 3 steps of reservoir modeling and flow simulation are carried out and they go from having homogeneous property models to incorporating standard 2-point geostatistical methods to using object-based models. The layer-cake models generate a rather uniform plume shape and increased pressure response. Meanwhile, two-point statistical models add more complexity to the size and shape of CO 2 plume, however are not capable of reproducing the pressure decline behavior. These results demonstrate homogeneous and 2-point geostatistical models are inadequate in interpreting subsurface heterogeneity, both due to their method and data limitations. Further work is being done with object-based models to produce a system of meandering rivers based on the geological concept of Shenhua injection site. This will help offset the data limitation and bring our model closer to geologic reality.

54 ENVIRONMENTAL SCIENCES↗

Cybersecurity Platform and Certification Framework Development for Extreme Fast Charging (XFC)-Integrated Charging Ecosystem (Final Project Report)

This report summarizes a pioneering effort in Electric Vehicle charging infrastructure ecosystem cybersecurity requirements, assessment methodologies, functional verification, as well as embodiment of the key technologies in the form of hardware and software tools being made available to the public. EPRI led a team of experts, as well as a stakeholder coalition encompassing all key actors in the EV charging infrastructure ecosystem that includes eXtreme Fast Charging (XFC) equipment (defined as 200kW or above). EV charging infrastructure in the United States is a patchwork of networks that have continued to grow organically and have been designed to serve the charging needs of the EV owners, who are their customers. In doing so, each network provider, as well as their connected entities such as the cloud Electric Vehicle Service Providers or EVSPs, utility back office, utility AMI networks, payment networks, as well as Original Equipment Manufacturer (EV manufacturer) telematics networks, have designed systems that may work well individually, but no single entity is responsible for the entire ecosystem to be secure in terms of data exchange. Furthermore, there is no uniformity in how each actor has implemented the cybersecurity requirements since no system-wide cybersecurity requirements existed prior to this project. The final project report describes the technical approach guided by the EV charging infrastructure cybersecurity working group, convened specifically for this project. The technical approach included definition of requirements at the ecosystem level, treated as a ‘system of systems’, and then passed down to individual systems (EVSE, EV, cloud EVSP, utility, and the payment networks), followed by developing the cybersecurity risk and vulnerability assessment methods, that were later applied to real-world cyber-physical systems at EPRI, ANL, and NREL laboratories, to validate both the process and the results. Finally, in a spotlight over the most vulnerable equipment, which is the EV charge station (AC or DC), the team developed a multi-layer cybersecurity implementation in the embedded domain embodied by the open-source Secure Network Interface Card (SNIC) demonstrating the various ways in which the infrastructure can be secured protecting against the identified attack surfaces. Finally, the entire process of EV infrastructure cybersecurity assessment was encapsulated in the Electric Vehicle Charging Cybersecurity Management (EVC2M) online GUI-based tool, that is expected to be released to the public. The report presents the objectives, the technical approach, the key results, and recommendations for future work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design and assessment of a novel SPECT system for desktop open-gantry imaging of small animals: A simulation study

Purpose: Given increasing efforts in biomedical research utilizing molecular imaging methods, development of dedicated high-performance small-animal SPECT systems has been growing rapidly in the last decade. In the present work, we propose and assess an alternative concept for SPECT imaging enabling desktop open-gantry imaging of small animals. Methods: The system, PERSPECT, consists of an imaging desk, with a set of tilted detector and pinhole collimator placed beneath it. The object to be imaged is simply placed on the desk. Monte Carlo (MC) and analytical simulations were utilized to accurately model and evaluate the proposed concept and design. Furthermore, a dedicated image reconstruction algorithm, finite-aperture-based circular projections (FABCP), was developed and validated for the system, enabling more accurate modeling of the system and higher quality reconstructed images. Image quality was quantified as a function of different tilt angles in the acquisition and number of iterations in the reconstruction algorithm. Furthermore, more complex phantoms including Derenzo, Defrise, and mouse whole body were simulated and studied. Results: The sensitivity of the PERSPECT was 207 cps/MBq. It was quantitatively demonstrated that for a tilt angle of 30°, comparable image qualities were obtained in terms of normalized squared error, contrast, uniformity, noise, and spatial resolution measurements, the latter at ∼0.6 mm. Furthermore, quantitative analyses demonstrated that 3 iterations of FABCP image reconstruction (16 subsets/iteration) led to optimally reconstructed images. Conclusions: The PERSPECT, using a novel imaging protocol, can achieve comparable image quality performance in comparison with a conventional pinhole SPECT with the same configuration. The dedicated FABCP algorithm, which was developed for reconstruction of data from the PERSPECT system, can produce high quality images for small-animal imaging via accurate modeling of the system as incorporated in the forward- and back-projection steps. Meanwhile, the developed MC model and the analytical simulator of the system can be applied for further studies on development and evaluation of the system.

60 APPLIED LIFE SCIENCES↗

Projected Second Tumor Risk and Dose to Neurocognitive Structures After Proton Versus Photon Radiotherapy for Benign Meningioma

Purpose: To calculated projected second tumor rates and dose to organs at risk (OAR) in patients with benign intracranial meningioma (BM), according to dosimetric comparisons between proton radiotherapy (PRT) and photon radiotherapy (XRT) treatment plans. Methods and Materials: Ten patients with BM treated at Massachusetts General Hospital during 2006-2010 with PRT were replanned with XRT (intensity-modulated or three-dimensional conformal radiotherapy), optimizing dose to the tumor while sparing OAR. Total dose was 54 Gy in 1.8 Gy per fraction for all plans. We calculated equivalent uniform doses, normal tissue complication probabilities, and whole brain-based estimates of excess risk of radiation-associated intracranial second tumors. Results: Excess risk of second tumors was significantly lower among PRT compared with XRT plans (1.3 vs. 2.8 per 10,000 patients per year, p < 0.002). Mean equivalent uniform doses were lower among PRT plans for the whole brain (19.0 vs. 22.8 Gy, p < 0.0001), brainstem (23.8 vs. 35.2 Gy, p = 0.004), hippocampi (left, 13.5 vs. 25.6 Gy, p < 0.0001; right, 7.6 vs. 21.8 Gy, p = 0.001), temporal lobes (left, 25.8 vs. 34.6 Gy, p = 0.007; right, 25.8 vs. 32.9 Gy, p = 0.008), pituitary gland (29.2 vs. 37.0 Gy, p = 0.047), optic nerves (left, 28.5 vs. 33.8 Gy, p = 0.04; right, 25.1 vs. 31.1 Gy, p = 0.07), and cochleas (left, 12.2 vs. 15.8 Gy, p = 0.39; right,1.5 vs. 8.8 Gy, p = 0.01). Mean normal tissue complication probability was <1% for all structures and not significantly different between PRT and XRT plans. Conclusions: Compared with XRT, PRT for BM decreases the risk of RT-associated second tumors by half and delivers significantly lower doses to neurocognitive and critical structures of vision and hearing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗