Search NASA⌕ Search

SEARCH · Search NASA

Results for “vacuum tubes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Miniature X-Ray Tubes

Miniature x-ray tubes proposed for use in portable instruments used to analyze minerals. Electrons from field emitter (instead of thermionic emitter) accelerated to target to generate x-rays. Fabricated from silicon wafers, micromachined field emitters (MFEs) not subject to breakage or restrictions on lifetimes, and tolerate vacuums that filaments cannot. Miniature x-ray tubes very robust, immune to shock and vibration, and permanently sealed with getter for continued pumping. Combined with solid-state x-ray detectors for analysis of x-ray fluorescence.

Bearman, Gregory H.↗

Study of equilibrium air total radiation.

Equilibrium air total radiation mechanism, vacuum UV radiation and relation to hypervelocity entry studied, using shock tube blunt model test flow

VACUUM ULTRAVIOLET↗

Deuterium Extraction from Helium with a Vanadium Vacuum Permeator: Commissioning of the Tritium Extraction eXperiment (TEX)

Here, the Tritium Extraction eXperiment (TEX) is a forced-convection lead-lithium (PbLi) loop in the Safety and Tritium Applied Research (STAR) facility at Idaho National Laboratory (INL) with the purpose of providing validation data for the vacuum permeator tritium extraction concept. A vanadium tube of 1000 mm length, 12.7 mm outside diameter, and 0.50 mm wall thickness is installed in the test section of TEX. The installed vanadium tube is characterized to quantify impurity concentrations, surface chemistry, and microstructure to elucidate permeation phenomena observed in experimentation. Herein, the permeation properties of the vanadium tube are characterized by measuring deuterium permeation at 300 °C, 325 °C, and 350 °C at 100 kPa, 125 kPa, and 150 kPa total pressures with 5000 ppm deuterium in helium gas mixture in a once-through flow configuration. The hydrogen isotope permeation through the vanadium tube in the test section is measured with quadrupole mass spectrometers and the hydrogen isotope concentration in the feed and retentate gas stream is measured with gas chromatography. The transient permeation results are modeled with MELCOR-TMAP, a thermal-hydraulic tritium transport code, and compared well with literature data.

70 - PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SimELIT: A Novel GUI-Based Comprehensive Ion Trajectory Simulation Software for Mass Spectrometry

Ion trajectory simulation in mass spectrometry systems from injection to detection is technically challenging but very important for better understanding the ion dynamics in instrument development. Here, in this work, we present SimELIT (Simulator of Eulerian and Lagrangian Ion Trajectories), a novel ion trajectory simulation platform. SimELIT is built upon a suite of multiphysics solvers compiled into OpenFOAM (an open-source numerical solver library particularly used for computational mechanics), with a simple web-based graphical user interface (GUI) allowing users to define the details of OpenFOAM cases and run simulations. SimELIT is a modular program and can provide extensions of physics (e.g., gas flows, electrodynamic fields) and thus enable ion trajectory simulations from the ion source to detector. The current version (SimELIT) provides two numerical solvers for ion trajectory simulations–(1) a Lagrangian particle tracker in vacuum and (2) a Eulerian ion density solver in background gas in the presence of electric fields. Here, we describe the architecture of SimELIT, including its use of Docker and the React Framework, and demonstrate the computation of ion trajectories of multiple m/z values in a static/linear voltage drop in vacuum (across a 1 m long flight tube). Further, the drift motion of ions under 1 Torr pressure conditions in a static background (N 2 ) gas through a 20 V/cm static electric field is shown. The results produced from SimELIT were compared with SIMION and theoretical estimates. In addition, we report the computation of ion trajectories in electrodynamic fields within a planar FAIMS device operating at atmospheric pressure.

97 MATHEMATICS AND COMPUTING↗

Extinction Monitoring of Pulsed Proton Beams Using FPGA-Based Peak Detection

The Mu2e experiment at Fermilab imposes stringent requirements on the elimination of out-of-time beam in its pulsed proton beam - a requirement known as "extinction". We present a method to measure the out-of-time particle rates to calculate the level of extinction in the inter-pulse gaps. The proposed method utilizes an array of quartz Cherenkov radiators and photomultiplier tubes to detect particles scattered from a vacuum chamber in the M4 transfer beamline at Fermilab.The measurement will employ a new μTCA-based FPGA system for data acquisition and signal processing, utilizing real-time peak detection algorithms to count scattered beam particles. By integrating data over many transfers, the time profile of the out-of-time beam will be resolved to fractional levels relative to that of the in-time beam. These results are compared with G4beamline simulations to validate models of beam transport, dynamics, and extinction, providing critical input for optimizing beam delivery to Mu2e.

Hensley, Ryan [UC, Davis]↗

Development of a high power 12GHz PPM focused traveling wave tube

An analytical and experimental program to demonstrate the technical feasibility of a high efficiency coupled cavity traveling wave tube with periodic permanent magnetic focusing operating at 12.06 GHz, with 1 to 2 kilowatts CW power is described. Such a tube would ultimately be used for broadcasting power transmission from a satellite. The electron gun was designed to be demountable with a replaceable cathode, and the tube to be operable in a bakeable vacuum chamber with its collector replaced by a collector. Therefore, the high efficiency design was concerned with the slow wave structure only, utilizing velocity resynchronization. A special adapter was designed which incorporated an electromagnet refocusing section and a collector baseplate to facilitate testing the collector. CW output power of 1000 watts yielding 21.5% electronic efficiency was demonstrated, with a minimum output power of 525 watts across the specified 160 MHz bandwidth.

Lewis, R.↗

Microparticle accelerator of unique design

A microparticle accelerator has been devised for micrometeoroid impact and cratering simulation; the device produces high-velocity (0.5-15 km/sec), micrometer-sized projectiles of any cohesive material. In the source, an electrodynamic levitator, single particles are charged by ion bombardment in high vacuum. The vertical accelerator has four drift tubes, each initially at a high negative voltage. After injection of the projectile, each tube is grounded in turn at a time determined by the voltage and charge/mass ratio to give four acceleration stages with a total voltage equivalent to about 1.7 MV.

Vedder, J. F.↗

Measurement and analysis of a small nozzle plume in vacuum

Pitot pressures and flow angles are measured in the plume of a nozzle flowing nitrogen and exhausting to a vacuum. Total pressures are measured with Pitot tubes sized for specific regions of the plume and flow angles measured with a conical probe. The measurement area for total pressure extends 480 mm (16 exit diameters) downstream of the nozzle exit plane and radially to 60 mm (1.9 exit diameters) off the plume axis. The measurement area for flow angle extends to 160 mm (5 exit diameters) downstream and radially to 60 mm. The measurements are compared to results from a numerical simulation of the flow that is based on kinetic theory and uses the direct-simulation Monte Carlo (DSMC) method. Comparisons of computed results from the DSMC method with measurements of flow angle display good agreement in the far-field of the plume and improve with increasing distance from the exit plane. Pitot pressures computed from the DSMC method are in reasonably good agreement with experimental results over the entire measurement area.

Penko, P. F.↗

Safe Affordable Fission Engine (SAFE 30) Module Conductivity Test Thermal Model Correlation

Two SAFE 30 modules were tested to determinate the thermal conductivity efficiency of the tri-cusps filled between the heat pipe and the heater cores. The modules consisted of four one-inch diameter tubes with heaters joined to an empty 1 inch diam. tube. The test was conducted on a vacuum chamber with 4 configurations: tri-cusps filled with and without radiation shielding and non-filled tri-cusps with and without radiation shielding. The tri-cusps material helps the bonding of the heat pipe to the four electric heater cores, filling the gap between the pipes. The baseline configuration is a brazed joint between the pipe. The test consisted of controlling the power applied to the heaters until a set surface temperature is reach. The temperatures varied between a max. of 800 C to 500 C. Test data, input energy and chamber surface temperature from each individual test, was used as boundary conditions for the model. Nodes located on the same location as the test thermocouples were plotted again test data to determinate the accuracy of the analysis. The unknown n variables on the analysis are the radiation emissivity of the pipe and chamber and the radiation view factor between the module and the chamber. A correlation was determined using a parametric analysis varying the surface emissivity and view factor until a good match was reach.

Roman, Jose↗

Cryogenic Transfer Line Chilldown

The transient behavior of a small scale cryogenic transfer line was investigated during chilldown to cryogenic temperatures. The vacuum-jacketed apparatus consisted of a vertical tube followed by a near horizontal tube. The apparatus was equipped with view ports in the near horizontal section to allow visual observation of the flow patterns. Wall temperatures were measured at various locations along the length of the transfer line. Each test was conducted at a constant liquid volumetric flowrate at the transfer line inlet until saturation temperatures were obtained throughout the system.

VanDresar, Neil T.↗

Spill-Resistant Alkali-Metal-Vapor Dispenser

A spill-resistant vessel has been developed for dispensing an alkali-metal vapor. Vapors of alkali metals (most commonly, cesium or rubidium, both of which melt at temperatures slightly above room temperature) are needed for atomic frequency standards, experiments in spectroscopy, and experiments in laser cooling. Although the present spill-resistant alkali-metal dispenser was originally intended for use in the low-gravity environment of outer space, it can also be used in normal Earth gravitation: indeed, its utility as a vapor source was confirmed by use of cesium in a ground apparatus. The vessel is made of copper. It consists of an assembly of cylinders and flanges, shown in the figure. The uppermost cylinder is a fill tube. Initially, the vessel is evacuated, the alkali metal charge is distilled into the bottom of the vessel, and then the fill tube is pinched closed to form a vacuum seal. The innermost cylinder serves as the outlet for the vapor, yet prevents spilling by protruding above the surface of the alkali metal, no matter which way or how far the vessel is tilted. In the event (unlikely in normal Earth gravitation) that any drops of molten alkali metal have been shaken loose by vibration and are floating freely, a mesh cap on top of the inner cylinder prevents the drops from drifting out with the vapor. Liquid containment of the equivalent of 1.2 grams of cesium was confirmed for all orientations with rubbing alcohol in one of the prototypes later used with cesium.

Klipstein, William↗

Measurements of HO2 chemical kinetics with a new detection method

Research for the period from December 1, 1985 to May 31, 1986 is discussed, i.e., the reaction rate constant of HO2+O3 has been measured with a discharge-flow-tube apparatus. The HO2 radical was detected by the OH(A-X) photofragment emission produced from photodissociative excitation of HO2 at 147 nm. In the meantime, the optical emissions produced by the vacuum ultraviolet excitation of chemical species in the flow tube were investigated and used to examine the possibility for their interference with the HO2 detection. The research results are summarized below.

Lee, L. C.↗

Design of the Electromagnetic Particle Injector (EPI) for Tokamak Deployment

Both predicting and controlling disruptions are critical and urgent issues for ITER as some disruptions with a short warning time may be unavoidable. For these cases, a rapid response disruption mitigation system (DMS) referred to as the electromagnetic particle injector (EPI) is being developed. The primary advantages of the EPI are its fast response time and high velocity, which have been demonstrated in offline experiments (Raman et al., 2021). The EPI is capable of accelerating a metallic sabot electromagnetically using a rail gun to the required velocities ( > 2 km/s) within 2 ms. Two high-field racetrack magnets able to generate fields over 2 T are positioned above and below the rails to permit high velocity at low rail currents, a requirement to minimize electrode erosion. At the end of the acceleration phase, a sabot capture mechanism retains the spent sabot inside the vacuum chamber that houses the EPI. At this point, it releases well-defined microspheres, or a shell pellet, of a radiative payload into the disrupting plasma. A remotely operated sabot loading system positioned behind the injector contains several pre-equipped sabots that can be loaded by an operator from the tokamak control room. The injector is interfaced to the tokamak through a guide tube attached to the front of the EPI vacuum chamber. Finally, the advantages of the EPI system over other DMSs under consideration are described in conjunction with the details of an EPI system designed for near-term test on an existing large tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Water Membrane Evaporator

A water membrane evaporator (WME) has been conceived and tested as an alternative to the contamination-sensitive and corrosion-prone evaporators currently used for dissipating heat from space vehicles. The WME consists mainly of the following components: An outer stainless-steel screen that provides structural support for the components mentioned next; Inside and in contact with the stainless-steel screen, a hydrophobic membrane that is permeable to water vapor; Inside and in contact with the hydrophobic membrane, a hydrophilic membrane that transports the liquid feedwater to the inner surface of the hydrophobic membrane; Inside and in contact with the hydrophilic membrane, an annular array of tubes through which flows the spacecraft coolant carrying the heat to be dissipated; and An inner exclusion tube that limits the volume of feedwater in the WME. In operation, a pressurized feedwater reservoir is connected to the volume between the exclusion tube and the coolant tubes. Feedwater fills the volume, saturates the hydrophilic membrane, and is retained by the hydrophobic membrane. The outside of the WME is exposed to space vacuum. Heat from the spacecraft coolant is conducted through the tube walls and the water-saturated hydrophilic membrane to the liquid/vapor interface at the hydrophobic membrane, causing water to evaporate to space. Makeup water flows into the hydrophilic membrane through gaps between the coolant tubes.

Ungar, Eugene K.↗

Study of equilibrium air total radiation.

Equilibrium air total radiation mechanism, vacuum UV radiation and relation to hypervelocity entry studied, using shock tube blunt model test flow

ATMOSPHERIC RADIATION↗

Hollow Fiber Spacesuit Water Membrane Evaporator Development and Testing for Advanced Spacesuits

Grant Bue and Matthew Vogel presented the two types of Spacesuit Water Membrane Evaporators (SWME) that were developed based on hydrophobic microporous membranes. One type, the Sheet Membrane (SaM) SWME, is composed of six concentric Teflon sheet membranes fixed on cylindrical-supporting screens to form three concentric annular water channels. Those water channels are surrounded by vacuum passages to draw off the water vapor that passes through the membrane. The other type, the Hollow Fiber (HoFi) SWME, is composed of more than 14,000 tubes. Water flows through the tubes and water vapor passes through the tube wall to the shell side that vents to the vacuum of space. Both SWME types have undergone testing to baseline the performance at predicted operating temperatures and flow rates; the units also have been subjected to contamination testing and other conditions to test resiliency.

Bue, Grant C.↗

Helium-Cooled Black Shroud for Subscale Cryogenic Testing

This shroud provides a deep-space simulating environment for testing scaled-down models of passively cooling systems for spaceflight optics and instruments. It is used inside a liquid-nitrogen- cooled vacuum chamber, and it is cooled by liquid helium to 5 K. It has an inside geometry of approximately 1.6 m diameter by 0.45 m tall. The inside surfaces of its top and sidewalls have a thermal absorptivity greater than 0.96. The bottom wall has a large central opening that is easily customized to allow a specific test item to extend through it. This enables testing of scale models of realistic passive cooling configurations that feature a very large temperature drop between the deepspace-facing cooled side and the Sun/Earth-facing warm side. This shroud has an innovative thermal closeout of the bottom wall, so that a test sample can have a hot (room temperature) side outside of the shroud, and a cold side inside the shroud. The combination of this closeout and the very black walls keeps radiated heat from the sample s warm end from entering the shroud, reflecting off the walls and heating the sample s cold end. The shroud includes 12 vertical rectangular sheet-copper side panels that are oriented in a circular pattern. Using tabs bent off from their edges, these side panels are bolted to each other and to a steel support ring on which they rest. The removable shroud top is a large copper sheet that rests on, and is bolted to, the support ring when the shroud is closed. The support ring stands on four fiberglass tube legs, which isolate it thermally from the vacuum chamber bottom. The insides of the cooper top and side panels are completely covered with 25- mm-thick aluminum honeycomb panels. This honeycomb is painted black before it is epoxied to the copper surfaces. A spiral-shaped copper tube, clamped at many different locations to the outside of the top copper plate, serves as part of the liquid helium cooling loop. Another copper tube, plumbed in a series to the top plate s tube, is clamped to the sidewall tabs where they are bolted to the support ring. Flowing liquid helium through these tubes cools the entire shroud to 5 K. The entire shroud is wrapped loosely in a layer of double-aluminized Kapton. The support ring s inner diameter is the largest possible hole through which the test item can extend into the shroud. Twelve custom-sized trapezoidal copper sheets extend inward from the support ring to within a few millimeters of the test item. Attached to the inner edge of each of these sheets is a custom-shaped strip of Kapton, which is aluminum- coated on the warm-facing (outer) side, and has thin Dacron netting attached to its cold-facing side. This Kapton rests against the test item, but the Dacron keeps it from making significant thermal contact. The result is a non-contact, radiatively reflective thermal closeout with essentially no gap through which radiation can pass. In this way, the part of the test item outside the shroud can be heated to relatively high temperatures without any radiative heat leaking to the inside.

Tuttle, James↗