Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

PMU Data Integrity Evaluation through Analytics on a Virtual Test-Bed

Power systems are rapidly becoming populated by phasor measurement units (PMUs) in ever increasing numbers. PMUs are critical components of today s energy management systems, designed to enable near real-time wide area monitoring and control of the electric power system. They are able to measure highly accurate bus voltage phasors as well as branch current phasors incident to the buses at which PMUs are equipped. Synchrophasor data is used for applications varying from state estimation, islanding control, identifying outages, voltage stability detection and correction, disturbance recording, and others. However, PMU-measured readings may suffer from errors due to meter biases or drifts, incorrect configurations, or even cyber-attacks. Furthermore, the testing of early PMUs showed a large disparity between the reported values from PMUs provided by different manufacturers, particularly when frequency was off-nominal, during dynamic events, and when harmonic/inter-harmonic content was present. Detection and identification of PMU gross measurement errors are thus crucial in maintaining highly accurate phasor readings throughout the system. In this paper, we present our work in conducting analytics to determine the trustworthiness and worth of the PMU readings collected across an electric network system. By implementing the IEEE 118 bus test case on a virtual test bed (VTB) , we are able to emulate PMU readings (bus voltage and branch current phasors in addition to bus frequencies) under normal and abnormal conditions using (virtual) PMU sensors deployed across major substations in the network. We emulate a variety of failures such as bus, line, transformer, generator, and/or load failures. Data analytics on the voltage phase angles and frequencies collected from the PMUs show that specious (or compromised) PMU device(s) can be identified through abnormal behaviour by comparing the trend of its frequency and phase angle reading with the ensemble of all other PMU readings in the network. If the reading trend of a particular PMU deviates from the weighted average of the reading trends of other PMUs at nearby substations, then it is likely that the PMU is malfunctioning. We assign a weight to each PMU denoting how electric-topology-wise close it is from where the PMU under consideration is located. The closer a PMU is, the higher the weight it has. To compute the closeness between two nodes in the power network, we employ a form of the resistance distance metric. It computes the electrical distance by taking into consideration the underlying topology as well as the physical laws that govern the electrical connections or flows between the network components. The detection accuracy of erroneous PMUs should be improved by employing this metric. We present results to validate the proposed approach. We also discuss the effectiveness of using an end-to-end VTB approach that allows us to investigate different types of failures and their responses as seen by the ensemble of PMUs. The collected data on certain types of events may be amenable to certain types of analysis (e.g., alerting for sudden changes can be done on a small window of data) and hence determine the data analytics architectures is required to evaluate the streaming PMU data.

and data analytics architecture.↗

Tractable Learning in Underexcited Power Grids

Estimating the structure of physical flow networks, such as power grids, is critical to secure delivery of energy. This article discusses statistical structure estimation in power grids in the “underexcited” regime, where a subset of internal nodes has zero injection fluctuations. Prior estimation algorithms based on nodal voltages fail for such grids as the voltage covariance matrix is not invertible. Here, we propose a novel topology learning algorithm for learning underexcited general networks. Our algorithm uses physics-informed conservation laws to first identify the zero-injection buses and their neighbors, and then estimates the remaining edges in the grid. We prove the asymptotic correctness of our algorithm for grids with nonadjacent internal zero-injection nodes. More important, we theoretically analyze our algorithm’s efficacy under noisy measurements, and determine bounds on maximum noise under which asymptotically correct recovery is guaranteed. Our approach is validated through simulations with voltage samples generated on test distribution grids with real injection data and nonlinear power flow models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy breakdown in capacitive deionization

We explored the energy loss mechanisms in capacitive deionization (CDI). We hypothesize that resistive and parasitic losses are two main sources of energy losses. We measured contribution from each loss mechanism in water desalination with constant current (CC) charge/discharge cycling. Resistive energy loss is expected to dominate in high current charging cases, as it increases approximately linearly with current for fixed charge transfer (resistive power loss scales as square of current and charging time scales as inverse of current). On the other hand, parasitic loss is dominant in low current cases, as the electrodes spend more time at higher voltages. We built a CDI cell with five electrode pairs and standard flow between architecture. We performed a series of experiments with various cycling currents and cut-off voltages (voltage at which current is reversed) and studied these energy losses. To this end, we measured series resistance of the cell (contact resistances, resistance of wires, and resistance of solution in spacers) during charging and discharging from voltage response of a small amplitude AC current signal added to the underlying cycling current. We performed a separate set of experiments to quantify parasitic (or leakage) current of the cell versus cell voltage. We then used these data to estimate parasitic losses under the assumption that leakage current is primarily voltage (and not current) dependent. Our results confirmed that resistive and parasitic losses respectively dominate in the limit of high and low currents. We also measured salt adsorption and report energy-normalized adsorbed salt (ENAS, energy loss per ion removed) and average salt adsorption rate (ASAR). As a result, we show a clear tradeoff between ASAR and ENAS and show that balancing these losses leads to optimal energy efficiency.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Diffusion Through Single And Double Layer Shields And Induced Voltages From Low Frequency Electromagnetic Environments

The diffusion through shells consisting of either a single conducting or double conducting layers are examined. Exterior drives resulting from Electromagnetic Radiation (EMR), Electromagnetic Pulse (EMP), nearby (indirect) lightning, and DC (low frequency) magnetic fields are used. Both the interior field and the induced voltage from a maximally oriented and sized single turn loop are estimated. It is shown that the loop voltage with the empty cavity bounds the case where the center region is excluded by a conducting object. The cases of interior magnetic and electric fields from an exterior magnetic drive and the interior electric field from an exterior electric drive are both solved; the magnetic interior field from an exterior magnetic drive is the only case that results in a nonzero low frequency penetration.

42 ENGINEERING↗

Laser Doppler vibrometry for piezoelectric coefficient ($d_{33}$) measurements in irradiated aluminum nitride

Sensors used for experiments in advanced reactors must survive in harsh environments. Few material systems can be used to construct sensors viable for extreme conditions. Aluminum nitride (AlN) is one such material because it has high thermal stability and radiation resistance and sustains good piezoelectric and dielectric properties at high temperatures. In this work, the piezoelectric coefficient $d_{33}$ of the AlN single-crystal with thermal and irradiation damage was investigated using an indirect method with a laser Doppler vibrometer (LDV). Surface electrodes were deposited on the AlN samples, and the vibration response of the samples to an applied voltage was monitored using the LDV as a function of the excitation frequency. The $d_{33}$ estimation was based on the excitation voltage and the thickness-mode displacement extracted from the LDV measurements. Further, six AlN substrates were irradiated with 8 MeV Al 2+ at three fluences (10 15 , 10 16 , and 10 17 ions/cm 2 ) and two temperatures (300 °C and 500 °C). The $d_{33}$ for the six irradiated samples and one pristine sample were measured, and the measurement uncertainty was estimated based on five repeated tests. All samples were also measured by a commercial piezometer for comparison. The experimental results demonstrate that the piezoelectric coefficients obtained by LDV were about 0.8–1.16 pm/V lower than those obtained by the piezometer. With the compensation of the clamping effect, the corrected LDV values are similar to the piezometer results. Both show similar trends in all samples, which validates the feasibility of the proposed method for $d_{33}$ measurement. Based on the LDV results, the irradiated samples show a 12%–22% decrease in $d_{33}$ compared with the pristine samples. The samples irradiated under the same fluence at a higher temperature (500 °C) demonstrated a lower $d_{33}$ than those at 300 °C. The effect of the retro-reflective tape, sample temperature, and sample size on the $d_{33}$ measurement were also studied.

36 MATERIALS SCIENCE↗

Voltage Probability Density Function Shaping Control Strategy Considering Grid Operational Uncertainties

It is well-known that power systems operation always affected by various uncertainties which make the bus voltage a random process that can be characterized by its probability density function (PDF) at any time instant. In this context, this paper presents a novel PDF-based voltage control framework for power systems. By modeling voltage as a stochastic process, we formulate a stochastic differential equationthat captures grid uncertainties. The associated Fokker-Planck-Kolmogorov equation is derived to describe the evolution of the voltage PDF, which enables the formulation of a PDF-shaping control strategy. To simplify the PDF control formulation, a B-spline neural network is introduced for real-time estimation and regulation of the voltage distribution. The proposed PDF control law updates voltage references for energy storage systems and synchronous generators using real-time PDF measurements and feedback signals. The proposed method is validated on a modified Kundur’s two-area system. Simulation results demonstrate that the controller can significantly improve the voltage stability under stochastic conditions, highlighting its effectiveness in modern inverter-rich grids.

Gui, Yonghao [ORNL] (ORCID:0000000250435534)↗

The contribution of radio-frequency rectification to field-aligned losses of high-harmonic fast wave power to the divertor in the National Spherical Torus eXperiment

The National Spherical Torus eXperiment (NSTX) can exhibit a major loss of high-harmonic fast wave (HHFW) power along scrape-off layer (SOL) field lines passing in front of the antenna, resulting in bright and hot spirals on both the upper and lower divertor regions. One possible mechanism for this loss is RF sheaths forming at the divertors. Here, we demonstrate that swept-voltage Langmuir probe characteristics for probes under the spiral are shifted relative to those not under the spiral in a manner consistent with RF rectification. We estimate both the magnitude of the RF voltage across the sheath and the sheath heat flux transmission coefficient in the presence of the RF field. Although precise comparison between the computed heat flux and infrared (IR) thermography cannot yet be made, the computed heat deposition compares favorably with the projections from IR camera measurements. The RF sheath losses are significant and contribute substantially to the total SOL losses of HHFW power to the divertor for the cases studied. This work will guide future experimentation on NSTX-U, where a wide-angle IR camera and a dedicated set of coaxial Langmuir probes for measuring the RF sheath voltage directly will quantify the contribution of RF sheath rectification to the heat deposition from the SOL to the divertor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultrasonic input-output for transmitting and receiving longitudinal transducers coupled to same face of isotropic elastic plate

The quantitative understanding of ultrasonic nondestructive evaluation parameters such as the stress wave factor were studied. Ultrasonic input/output characteristics for an isotropic elastic plate with transmitting and receiving longitudinal transducers coupled to the same face were analyzed. The asymptotic normal stress is calculated for an isotropic elastic half space subjected to a uniform harmonic normal stress applied to a circular region at the surface. The radiated stress waves are traced within the plate by considering wave reflections at the top and bottom faces. The output voltage amplitude of the receiving transducer is estimated by considering only longitudinal waves. Agreement is found between the output voltage wave packet amplitudes and times of arrival due to multiple reflections of the longitudinal waves.

Williams, J. H., Jr.↗

Calculating Conductance of Ion Channels

We have simulated two small ion channels in a water/membrane system, which consists of 71,000-72,000 atoms, and have estimated the conductance by way of counting ions crossing these channels in applied field. The calculated values of conductance have been compared with predictions of the electrodiffusion model. In a recently developed theoretical framework, all commonly used assumptions of the model can be tested. If they are satisfied, which is often the case, the approach provides a rigorous way to extrapolate conductance calculated at one voltage to other voltages. This, in turn, allows for efficient estimations of current-voltage dependence, examining rectifying behavior of channels and calculating the reversal potential. Furthermore, the consistency of the results can be precisely tested. Simulations at microsecond time scales are required to sufficiently reduce statistical errors and separate them from possible systematic errors. Only then the accuracy of the proposed approach can be properly tested. Linking simulations with electrophysiology provides a stringent, highly relevant test for the correctness of computer simulations of ion channels. Considering biological, medical and pharmaceutical importance of these proteins, results of the proposed study might motivate the development of improved hardware and software that would enable applying a similar strategy to more complex channels at longer times.

Ion↗

Interaction between the SPS solar power satellite solar array and the magnetospheric plasma

The results of study to determine the effects of space plasmas on a large GaAs solar cell array using solar reflectors at a concentration ratio of two in geostationary orbit are summarized. It was concluded that the system could function in the GEO environment if certain design changes were implemented. These included conductive coatings on the solar cells, changing the reflector material from Kapton to a higher conductivity material, and oversizing the array to compensate for a 0.7% parasitic load due to losses from the ambient magnetospheric plasma. The operation of the solar powered earth orbit transfer vehicle (EOTV) was also examined and it was concluded that LEO servere arcing would take place on all high voltage negative portions of the array. The parasitic load loss at LEO was estimated at 3%. Operation of a high voltage array at LEO represents a major problem. Charge exchange ion feedback from argon ion thrusters located near the EOTV solar array was also examined and all problems found were believed to be solvable by the placement of protective ground screens.

Freeman, J. W.↗

Smart Power Supply for Battery-Powered Systems

A power supply for battery-powered systems has been designed with an embedded controller that is capable of monitoring and maintaining batteries, charging hardware, while maintaining output power. The power supply is primarily designed for rovers and other remote science and engineering vehicles, but it can be used in any battery alone, or battery and charging source applications. The supply can function autonomously, or can be connected to a host processor through a serial communications link. It can be programmed a priori or on the fly to return current and voltage readings to a host. It has two output power busses: a constant 24-V direct current nominal bus, and a programmable bus for output from approximately 24 up to approximately 50 V. The programmable bus voltage level, and its output power limit, can be changed on the fly as well. The power supply also offers options to reduce the programmable bus to 24 V when the set power limit is reached, limiting output power in the case of a system fault detected in the system. The smart power supply is based on an embedded 8051-type single-chip microcontroller. This choice was made in that a credible progression to flight (radiation hard, high reliability) can be assumed as many 8051 processors or gate arrays capable of accepting 8051-type core presently exist and will continue to do so for some time. To solve the problem of centralized control, this innovation moves an embedded microcontroller to the power supply and assigns it the task of overseeing the operation and charging of the power supply assets. This embedded processor is connected to the application central processor via a serial data link such that the central processor can request updates of various parameters within the supply, such as battery current, bus voltage, remaining power in battery estimations, etc. This supply has a direct connection to the battery bus for common (quiescent) power application. Because components from multiple vendors may have differing power needs, this supply also has a secondary power bus, which can be programmed a priori or on-the-fly to boost the primary battery voltage level from 24 to 50 V to accommodate various loads as they are brought on line. Through voltage and current monitoring, the device can also shield the charging source from overloads, keep it within safe operating modes, and can meter available power to the application and maintain safe operations.

Krasowski, Michael J.↗

Voltage Stability Constrained Moving Target Defense Against Net Load Redistribution Attacks

Moving target defense (MTD) using distributed flexible AC transmission system (D-FACTS) devices is a promising defense strategy to detect stealthy false data injection (FDI) attacks against the power system state estimation. However, all existing studies myopically perturb the reactance of D-FACTS lines without considering the system voltage stability. In this paper, we first illustrate voltage instability induced by MTDs in a three-bus system. To address this issue, we further propose a novel MTD framework that explicitly considers system voltage stability by using continuation power flow and voltage stability indices. We mathematically derive the sensitivity matrix of voltage stability index to line impedance, on which an optimization problem for maximizing voltage stability index is formulated. This framework is tested on the IEEE 14-bus and the IEEE 118-bus transmission systems, in which net load redistribution attacks are launched by sophisticated attackers. Here, the simulation results show the effectiveness of the proposed framework in circumventing the voltage instability while maintaining the detection effectiveness of MTD. We conduct case studies with and without the proposed framework under different MTD planning and operational methods. The impacts of the proposed two methods on attack detection effectiveness and system economic metrics are also revealed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Influence of Al{sub 2}O{sub 3} layer insertion on the electrical properties of Ga-In-Zn-O thin-film transistors

To investigate the influence of ionic/covalent interface of Al{sub 2}O{sub 3}/SiO{sub 2} gate insulator on the electrical properties of thin-film transistors (TFTs) with ionic Ga-In-Zn-O (GIZO) semiconducting channel layers, Al{sub 2}O{sub 3} layers of different thickness were introduced between SiO{sub 2} and GIZO using plasma-enhanced atomic layer deposition. The GIZO layers were obtained by DC magnetron sputtering using a GIZO target (Ga:In:Zn = 1:1:1 mol. %). The GIZO TFTs with an Al{sub 2}O{sub 3}/SiO{sub 2} gate insulator exhibited positive threshold voltage (V{sub th}) shift (about 1.1 V), V{sub th} hysteresis suppression (0.23 V), and electron mobility degradation (about 13%) compared with those of a GIZO TFT with SiO{sub 2} gate insulator by the influence of ionic/ionic and ionic/covalent interface at Al{sub 2}O{sub 3}/GIZO and Al{sub 2}O{sub 3}/SiO{sub 2}, respectively. To clarify the origin of the positive V{sub th} shift, the authors estimated the shifts of flatband voltage (0.4 V) due to the dipole and the fixed charge (−1.1 × 10{sup 11}/cm{sup 2}) at Al{sub 2}O{sub 3}/SiO{sub 2} interface, from capacitance–voltage data for Pt/Al{sub 2}O{sub 3}/SiO{sub 2}/p-Si capacitors. Based on these experimental data, the authors found that the positive V{sub th} shift (1.1 V) could be divided into three components: the dipole (−0.4 V) and fixed charge (0.15 V) at the SiO{sub 2}/Al{sub 2}O{sub 3} interface, and the fixed charge (1.35 V) at the Al{sub 2}O{sub 3}/GIZO interface. Finally, it is noted that heterointerface of SiO{sub 2}/Al{sub 2}O{sub 3}/GIZO stacks is important not only to recognize mechanism of V{sub th} shift but also to design future TFTs with high-k dielectrics and low operating voltage.

42 ENGINEERING↗

Statistical Behavior of Low-Amplitude Power System Point-on-Wave Measurements

The power grid is undergoing massive changes to ensure resiliency and reliability in a more decentralized world. Distributed energy resources are becoming a prominent source of generation, potentially leading to a lack of centralized generation sources. Due to these new behaviors and system topologies, it is important to install measurement devices that are 1) accurate and 2) self-aware of their measurement quality. In this paper, a residential-scale microgrid is used to generate voltage and current waveforms, captured by Verivolt and National Instruments measurement equipment. A least-squares approach is used to separate the “clean” signals from the noise. Finally, Gaussian mixture modeling is used to approximate noise distributions, and it is shown these higher-order distribution estimates are a better fit to voltage and current noise profiles than single-mode Gaussian estimates.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Self-Sensing, Stretchable, Active Circuit Arrays: Liquid Metal Paste as a Combination Interconnect and Strain Sensor

Stretchable electrical interconnects and substrate materials are increasingly used to create flexible and con-formable electronic systems for soft robotics, smart textiles, and wearable devices. Wires fabricated using composite or liquid conductive inks encapsulated in silicone enable high strain and are mechanically robust. The resistance of these inter-connects increases with strain, which can present challenges for power delivery and signaling among electronic components. However, this effect can be used directly to estimate strain within a stretchable circuit without the need for additional sensor components. In this work, we present an approach for fabricating fully-stretchable, multi-layer active circuit arrays in silicone using liquid metal paste interconnects, in which power and data wires are re-purposed as strain sensors to estimate substrate deformation. As a proof-of-principle, we demonstrate a 3×3 active circuit array that self-senses relative voltage supply at each node to estimate deformation and consumes less than 10 mA per node. Each node is digitally addressable and performs both analog measurement and digital conversion. All interconnects are fabricated using liquid metal paste, and power, data, and sensing are performed over a shared, four-wire interface in this multi-layer stretchable printed circuit board.

99 GENERAL AND MISCELLANEOUS↗

A Two-Stage Kalman Filter Approach for Robust and Real-Time Power System State Estimation

As electricity demand continues to grow and renewable energy increases its penetration in the power grid, realtime state estimation becomes essential for system monitoring and control. Recent development in phasor technology makes it possible with high-speed time-synchronized data provided by Phasor Measurement Units (PMU). In this paper we present a two-stage Kalman filter approach to estimate the static state of voltage magnitudes and phase angles, as well as the dynamic state of generator rotor angles and speeds. Kalman filters achieve optimal performance only when the system noise characteristics have known statistical properties (zero-mean, Gaussian, and spectrally white). However in practice the process and measurement noise models are usually difficult to obtain. Thus we have developed the Adaptive Kalman Filter with Inflatable Noise Variances (AKF with InNoVa), an algorithm that can efficiently identify and reduce the impact of incorrect system modeling and/or erroneous measurements. In stage one, we estimate the static state from raw PMU measurements using the AKF with InNoVa; then in stage two, the estimated static state is fed into an extended Kalman filter to estimate the dynamic state. Simulations demonstrate its robustness to sudden changes of system dynamics and erroneous measurements.

Zhang, Jinghe↗

Leveraging AMI data for distribution system model calibration and situational awareness

The many new distributed energy resources being installed at the distribution system level require increased visibility into system operations that will be enabled by distribution system state estimation (DSSE) and situational awareness applications. Reliable and accurate DSSE requires both robust methods for managing the big data provided by smart meters and quality distribution system models. This paper presents intelligent methods for detecting and dealing with missing or inaccurate smart meter data, as well as the ways to process the data for different applications. It also presents an efficient and flexible parameter estimation method based on the voltage drop equation and regression analysis to enhance distribution system model accuracy. Finally, it presents a 3-D graphical user interface for advanced visualization of the system state and events. Moreover, we demonstrate this paper for a university distribution network with the state-of-the-art real-time and historical smart meter data infrastructure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A new approach to investigate leakage current mechanisms in infrared photodiodes from illuminated current-voltage characteristics

This paper presents a new approach to investigate leakage current mechanisms in infrared photodiodes from the illuminated current–voltage characteristics. The example of mid-wave mercury cadmium telluride photodiodes is presented to illustrate the new approach. The new method is suitable for evaluating diodes in an array environment as advance knowledge of any of the material or device parameters are not required. The thermal saturation current is estimated from the observed open circuit voltage and zero-bias current (photo-current) of the diode. The ohmic shunt resistance is estimated from the observed maximum dynamic impedance of the diode. The experimentally observed reverse bias diode current in excess of thermal current, photo-current, and ohmic shunt current is reported to be best described by an exponential function of the type, I{sub excess} = I{sub r0} + K{sub 1} exp (K{sub 2} V), where I{sub r0}, K{sub 1}, and K{sub 2} are fitting parameters and V is the applied bias voltage. Our investigations reveal a close link between the excess current and the sources of ohmic currents in the diode. Exponential growth of excess current with the applied bias voltage has been interpreted as an indication of soft breakdown of the diodes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗