Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage loss analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Large Angle Deviation in Grid-Following IBRs Upon Grid Voltage Dip

In the 2021 Texas Odessa large-scale solar PV tripping events, phase-locked-loop (PLL) loss of synchronism is identified as a major cause of solar PV tripping. When solar PVs detected a large phase angle deviation (e.g., 10 degrees), tripping commands were initiated. Here, the large phase angle deviation was triggered by a transmission line fault 200 miles away, which in turn led to approximately 30% voltage drop in the 345-kV system. This paper offers a plausible reason why grid-following inverter-based resources (IBRs) may experience a large angle deviation upon grid voltage dip. Critical operating conditions contributing to such phenomena are identified via analysis and their effects are demonstrated using electromagnetic transient (EMT) simulation. Furthermore, the effect of converter control, e.g., grid-following control vs. grid-forming control, is examined. It is found from EMT simulation results that frequency and voltage control are helpful in mitigating angle deviation. Furthermore, linear block diagrams are derived to examine why frequency control can effectively suppress large angle deviation.

14 SOLAR ENERGY↗

Seasonal Cost-Benefit Analysis of Automated Distribution Feeder Upgrades with Advanced Mitigation Technologies

The increasing deployment of distributed solar photovoltaics (DPV) to meet clean energy goals can trigger adverse grid operation issues, such as voltage excursions and the violation of thermal loading constraints of the power delivery elements (e.g., lines and transformers) on the evolving electricity infrastructure. Such integration issues would require distribution upgrades with associated costs to mitigate them and to maintain reliable and resilient grid operating conditions. Traditional distribution network upgrade approaches use a specific single snapshot analysis that is overly conservative. This study considers a multi-time point analysis to capture both moderate (probable bounds) and extreme grid operating conditions using time points such as minimum load with minimum photovoltaics (PV), maximum load with maximum PV, maximum load with minimum PV, and minimum load with maximum PV. Further, this study investigates seasonal variation impacts and associated distribution upgrade costs for a spring season case (March, representing a low load and high PV scenario) and a summer case (July, representing a high load and high PV scenario). Such seasonal analysis will allow system operators to characterize upgrade requirements and associated costs across various periods. Because the spatial distribution of DPV can impact upgrade and associated costs, this study investigates three common DPV deployment scenarios - randomly deployed, close to the substation, and far from the substation - at different penetration levels. Apart from spatial distribution impacts, this project evaluates the techno-economic impacts of the nodal photovoltaic penetration factor (NPPF) for generating the various DPV deployment scenarios at increasing penetration levels. This project investigates the impact of varying nodal PV-to-load ratios using conservative and extreme NPPF values of 3 and 10, respectively. This study investigates the deployment of traditional infrastructure upgrade strategies, such as installing new voltage regulating equipment, transformers and lines replacements, and the activation of advanced inverter functionality (e.g., autonomous volt/VAR) in expanding PV hosting capacity. Existing DPV systems are assumed to operate with the legacy unity power factor, and we considered the possibility of retrofitting such systems with the activation of volt/VAR control as integration standards and regulations continue to evolve to allow such functions. The cost-benefit analysis metrics used in study include distribution upgrade costs, average cost per watt of the upgrade cost, average marginal cost per watt of the upgrade cost, and power losses.

14 SOLAR ENERGY↗

Development of a mercury electromagnetic centrifugal pump for the SNAP-8 refractory boiler development program

An electromagnetic pump, in which pressure is developed in mercury because of the interaction of the magnetic field and current which flows as a result of the voltage induced in the mercury contained in the pump duct, was developed for the SNAP-8 refractory boiler test facility. Pump performance results are presented for ten duct configurations and two stator sizes. These test results were used to design and fabricate a pump which met the SNAP-8 criteria of 530 psi developed pressure at 12,500 lb/hr. The pump operated continuously for over 13,000 hours without failure or performance degradation. Included in this report are descriptions of the experimental equipment, measurement techniques, all experimental data, and an analysis of the electrical losses in the pump.

Fuller, R. A.↗

Radionuclide measurements by accelerator mass spectrometry at Arizona

Over the past years, Tandem Accelerator Mass Spectrometry (TAMS) has become established as an important method for radionuclide analysis. In the Arizona system the accelerator is operated at a thermal voltage of 1.8MV for C-14 analysis, and 1.6 to 2MV for Be-10. Samples are inserted into a cesium sputter ion source in solid form. Negative ions sputtered from the target are accelerated to about 25kV, and the injection magnet selects ions of a particular mass. Ions of the 3+ charge state, having an energy of about 9MeV are selected by an electrostatic deflector, surviving ions pass through two magnets, where only ions of the desired mass-energy product are selected. The final detector is a combination ionization chamber to measure energy loss (and hence, Z), and a silicon surface-barrier detector which measures residual energy. After counting the trace iosotope for a fixed time, the injected ions are switched to the major isotope used for normalization. These ions are deflected into a Faraday cup after the first high-energy magnet. Repeated measurements of the isotope ratio of both sample and standards results in a measurement of the concentration of the radionuclide. Recent improvements in sample preparation for C-14 make preparation of high-beam current graphite targets directly from CO2 feasible. Except for some measurements of standards and backgrounds for Be-10 measurements to date have been on C-14. Although most results have been in archaeology and quaternary geology, studies have been expanded to include cosmogenic C-14 in meteorites. The data obtained so far tend to confirm the antiquity of Antarctic meteorites from the Allan Hills site. Data on three samples of Yamato meteorites gave terrestrial ages of between about 3 and 22 thousand years.

Jull, A. J. T.↗

Results of a 2000 hour wear test of the NEXIS ion engine

The Nuclear Electric Xenon Ion System (NEXIS) ion thruster was developed for potential outer planet robotic missions under NASA's Prometheus program. This engine was designed to operate at power levels ranging from 16 to over 20 kWe at specific impulses of 6000 to 7500 s for burn times of up to 10 years, satisfying the requirements of nuclear electric propulsion systems such as that on the proposed Prometheus 1 mission to explore the icy moons of Jupiter. State-of-the-art performance and life assessment tools were used to design the thruster. Following the successful performance validation of a Laboratory Model thruster, Development Model hardware was fabricated and subjected to vibration and wear testing. The results of a 2000-hour wear test are reported herein. Thruster performance achieved the target requirements and was steady for the duration of the test. Ion optics performance was similarly stable. Discharge loss increases of 6 eV/ion were observed in the first 500 hours of the test and were attributed to primary electron energy decreases due to cathode insert conditioning. Relatively high recycle rates were observed and were identified to be high-voltage-to-ground arcs in the back of the thruster caused by wire insulation outgassing and electron penetration through the plasma screen. Field emission of electrons between the accelerator and screen grids was observed and attributed to evolution of field emitter sites at accelerator grid aperture edges caused by ion bombardment. Preliminary modeling and analysis indicates that the NEXIS engine can meet mission performance requirements over the required lifetime. Finally, successful validation of the NEXIS design methodology, design tools, and technologies with the results of the wear test and companion performance and vibration tests presents significant applicability of the NEXIS development effort to missions of near-term as well as long-term interest for NASA.

Nuclear Electric Xenon Ion System (NEXIS)Thruster ↗

Results of a 2000 Hour Wear Tof the NEXIS Ion Engine

The Nuclear Electric Xenon Ion System (NEXIS) ion thruster was developed for potential outer planet robotic missions under NASA's Prometheus program. This engine was designed to operate at power levels ranging from 16 to over 20 kWe at specific impulses of 6000 to 7500 s for burn times of up to 10 years, satisfying the requirements of nuclear electric propulsion systems such as that on the proposed Prometheus 1 mission to explore the icy moons of Jupiter. State-of-the-art performance and life assessment tools were used to design the thruster. Following the successful performance validation of a Laboratory Model thruster, Development Model hardware was fabricated and subjected to vibration and wear testing. The results of a 2000-hour wear test are reported herein. Thruster performance achieved the target requirements and was steady for the duration of the test. Ion optics performance was similarly stable. Discharge loss increases of 6 eV/ion were observed in the first 500 hours of the test and were attributed to primary electron energy decreases due to cathode insert conditioning. Relatively high recycle rates were observed and were identified to be high-voltage-to-ground arcs in the back of the thruster caused by wire insulation outgassing and electron penetration through the plasma screen. Field emission of electrons between the accelerator and screen grids was observed and attributed to evolution of field emitter sites at accelerator grid aperture edges caused by ion bombardment. Preliminary modeling and analysis indicates that the NEXIS engine can meet mission performance requirements over the required lifetime. Finally, successful validation of the NEXIS design methodology, design tools, and technologies with the results of the wear test and companion performance and vibration tests presents significant applicability of the NEXIS development effort to missions of near-term as well as long-term interest for NASA.

Thruster performance↗

Privacy-Preserving Robust Consensus for Distributed Microgrid Control Applications

Consensus-based distributed control has been proposed for coordinating distributed energy resources (DERs) in microgrids (MGs). As one key component, distributed average observers are used to estimate the average of a group of reference signals (e.g., voltage, current, or power). State-of-the-art distributed average observers could lead to loss of privacy due to information exchange on the communication channels. The DERs' reference signals, which contain private information, could be inferred by an eavesdropper. In this article, a privacy-preserving distributed average observer is proposed that is based on robust consensus and uses the state decomposition method to preserve privacy. Compared to the existing methods, the proposed observer does not require the knowledge of the reference signal's derivative and gives accurate and smooth estimation, and is thus applicable for MG distributed control applications. A detailed analysis regarding the convergence and privacy properties of the proposed observer is presented. Here, the proposed observer is implemented on hardware controllers and validated in the context of distributed MG control applications through hardware-in-the-loop (HIL) tests.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Current loss analysis in photoelectrochemical devices

Ongoing efforts to stabilize the operation of photoelectrochemical (PEC) devices remain critical for achieving economically viable solar fuel production, as devices with lifetimes on the order of 10 to 30 years are projected requirements for utility-scale, PEC device implementation. However, insight into the causes of device degradation and activity losses is generally provided by monitoring the device current, a quantity which masks the relative contributions of photovoltaic component degradation and electrocatalyst activity drops to overall performance losses. In this study, an approach for deconvoluting the various contributors to PEC device losses is described. In particular, the causes for observed fluctuations in device performance are determined through the collection of real-time, current–voltage data, paired with an analytical method that enables the decomposition of drops in device current into its constituent photovoltaic- and catalyst-driven performance losses. We test the validity of this approach by applying it to the data collected for a PEC hydrogen evolution test-bed.

14 SOLAR ENERGY↗

A Modeling Toolkit for Comparing AC and DC Electrical Distribution Efficiency in Buildings

Recently, there has been considerable research interest in the potential for DC distribution systems in buildings instead of the traditional AC distribution systems. Due to the need for performing power conversions between DC and AC electricity, DC distribution may provide electrical efficiency advantages in some systems. To support comparative evaluations of AC-only, DC-only, and hybrid AC/DC distribution systems in buildings, a new modeling toolkit called the Building Electrical Efficiency Analysis Model (BEEAM) was developed and is described in this paper. To account for harmonics in currents or voltages arising from nonlinear devices, the toolkit implements harmonic power flow, along with nonlinear device behavioral descriptions derived from empirical measurements. This paper describes the framework, network equations, device representations, and an implementation of the toolkit in an open source software package, including a component library and graphical interface for creating circuits. Simulations of electrical behavior and device and system efficiencies using the toolkit are compared with experimental measurements of a small office environment in a variety of operating and load configurations. A detailed analysis of uncertainty estimation is also provided. Key findings were that a comparison of predicted versus measured efficiencies and power losses in the validation testbed using the initial toolkit implementation predicted device- and system-level efficiencies with reasonably good accuracy under both balanced and unbalanced AC scenarios. An uncertainty analysis also revealed that the maximum estimated error for system efficiency across all scenarios was 3%, and measured and modeled system efficiency agreed within the experimental uncertainty in approximately half of the scenarios. Based on the correspondence between simulation and measurement, the toolkit is proposed by the authors as a potentially useful tool for comparing efficiency in AC, DC, and hybrid AC/DC distribution systems in buildings.

DC distribution↗

The role of oxygen in porous molybdenum electrodes for the alkali metal thermoelectric converter

A model for chemical reactions in porous molybdenum electrodes is presented which is based on thermochemical and kinetic data, known sodium-molybdenum-oxygen chemistry, X-ray diffraction analysis of molybdenum and molybdenum oxide electrodes, and the electrochemical behavior of the cell. Enhanced sodium transport through the electrode in its optimum performance state is found to be due to the high sodium ion conductivity of molten Na2MoO4 in the pores, and the electrical conduction to the molybdenum matrix by Na2Mo3O6. The decline of electrode performance is shown to be due to a combination of loss mechanisms for the Na-Mo-O compounds including reduction at short circuit, disproportionation of Na2Mo3O6 at open circuit, and the evaporation of Na2MoO4 at elevated temperature. It is suggested that operation of the cell at moderate voltage of about 0.5 V corresponding to maximum power may be a more stable condition for the porous electrode than open-circuit stand or short-circuit, where degradation reactions are heightened.

Williams, R. M.↗

A first principles analysis of potential-dependent structural evolution of active sites in Fe-N-C catalysts

Fe-N-C (iron–nitrogen–carbon) electrocatalysts have emerged as potential alternatives to precious metal-based materials for the oxygen reduction reaction (ORR). However, the structure of these materials under electrochemical conditions is not well understood, and their poor stability in acidic environments poses a formidable challenge for successful adoption in commercial fuel cells. To provide molecular-level insights into these complex phenomena, we combine periodic density functional theory (DFT) calculations, exhaustive treatment of coadsorption effects for ORR reaction intermediates, including O and OH, and comprehensive analysis of solvation stabilization effects to construct voltage-dependent ab initio thermodynamic phase diagrams that describe the in situ structure of the active sites. These structures are further linked to activity and stability descriptors that can be compared with experimental parameters such as the half-wave potential for ORR and the onset potential for carbon corrosion and CO 2 evolution. The results indicate that pyridinic Fe sites at zigzag carbon edges, as well as other edge sites, exhibit high activity for ORR compared to sites in the bulk. However, edges neighboring the active sites are prone to instability via overoxidation and consequent site loss. The results suggest that it could be beneficial to synthesize Fe-N-C catalysts with small sizes and large perimeter edge lengths to enhance ORR activity, while voltage fluctuations should be limited during fuel cell operation to prevent carbon corrosion of overoxidized edges.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fault tree analysis: NiH2 aerospace cells for LEO mission

The Fault Tree Analysis (FTA) is one of several reliability analyses or assessments applied to battery cells to be utilized in typical Electric Power Subsystems for spacecraft in low Earth orbit missions. FTA is generally the process of reviewing and analytically examining a system or equipment in such a way as to emphasize the lower level fault occurrences which directly or indirectly contribute to the major fault or top level event. This qualitative FTA addresses the potential of occurrence for five specific top level events: hydrogen leakage through either discrete leakage paths or through pressure vessel rupture; and four distinct modes of performance degradation - high charge voltage, suppressed discharge voltage, loss of capacity, and high pressure.

Klein, Glenn C.↗

High power density dc/dc converter: Selection of converter topology

The work involved in the identification and selection of a suitable converter topology is described. Three new dc/dc converter topologies are proposed: Phase-Shifted Single Active Bridge DC/DC Converter; Single Phase Dual Active Bridges DC/DC Converter; and Three Phase Dual Active Bridges DC/DC Converter (Topology C). The salient features of these topologies are: (1) All are minimal in structure, i.e., each consists of an input and output bridge, input and output filter and a transformer, all components essential for a high power dc/dc conversion process; (2) All devices of both the bridges can operate under near zero-voltage conditions, making possible a reduction of device switching losses and hence, an increase in switching frequency; (3) All circuits operate at a constant frequency, thus simplifying the task of the magnetic and filter elements; (4) Since, the leakage inductance of the transformer is used as the main current transfer element, problems associated with the diode reverse recovery are eliminated. Also, this mode of operation allows easy paralleling of multiple modules for extending the power capacity of the system; (5) All circuits are least sensitive to parasitic impedances, infact the parasitics are efficently utilized; and (6) The soft switching transitions, result in low electromagnetic interference. A detailed analysis of each topology was carried out. Based on the analysis, the various device and component ratings for each topology operating at an optimum point, and under the given specifications, are tabulated and discussed.

Divan, Deepakraj M.↗

Optimisation of the Kaplan hydropower system via PID 2 and digital twin

Here, this paper proposes a proportional–integral-double–derivative (PID 2 ) optimisation method for the Kaplan hydropower system by building a digital twin. The study first uses one multilayer perceptron (MLP) to model the hydroturbine dynamic and then adopts three connected MLPs to model the generator dynamic, both in an open-loop fashion. Inspired by stochastic distribution control (SDC) theory, we regard the training of the turbine's neural network model as a process control problem, and we propose minimising entropy loss to update the network parameters. The next step is to build the digital twin by connecting the neural network models with a PID 2 controller and a lead-lag exciter and run the whole model in a closed-loop fashion. After that, a binary search approach is applied to optimise the PID 2 parameters based on the obtained digital twin model. The simulation results show that the proposed method can reduce the mean square tracking error by more than 90%. Furthermore, the method is extended to jointly optimise the PID 2 controller and excitation system gains through multiobjective optimisation, leveraging Pareto frontier analysis to balance active power and voltage tracking performance. Simulation results confirm the effectiveness of the proposed method, achieving a 83.46% reduction in relative mean square error of active power, a 47.13% reduction in terminal voltage tracking error, and an 82.78% improvement in the overall scalarized objective.

Hydropower system↗

Busbar Design and Optimization for Voltage Overshoot Mitigation of a Silicon Carbide High-Power Three-Phase T-Type Inverter

The silicon carbide (SiC) devices have faster switching speed than that of the conventional silicon (Si) devices, which however may cause excessive device voltage overshoot. Larger gate resistance can help to restrain the overshoot, it however slows down the switching speed and increases switching losses. There are other methods that can mitigate the voltage overshoot, e.g., using low-inductance busbars, adding snubber circuits, etc. In this article, the busbar design for a 250-kW SiC three-level T-type inverter is investigated. The current commutation loops (CCLs) are first analyzed using a single-phase equivalent circuit. Then the detailed busbar design methods, especially a 3-D busbar design concept, are proposed to select the optimal stacking order for the multilayer laminated busbar and to address constraints posed by the physical terminal arrangements of SiC modules and dc-link capacitors. The stray inductance in each CCL is extracted via a finite element analysis and validated on the actual inverter busbar prototypes using an impedance analyzer. To further minimize the busbar stray inductance, a hybrid busbar structure with printed circuit board based buffer circuit using high-frequency decoupling capacitors is designed and evaluated in this article. Lastly, the effectiveness of the designed busbars as well as the buffer circuit are validated using experimental studies.

42 ENGINEERING↗

Thermal Modeling and Limitations for Power Electronics Embedded in Medium-Voltage Cables

As next-generation energy technologies gain traction and power demand increases, the existing electrical infrastructure faces significant stress, prompting innovative solutions to enhance the grid's capacity and lifespan. This work explores the possibility of embedding medium-voltage (MV) power electronics directly inline with the cable, and the resulting thermal challenges. Since the majority of power distribution cables installed in the U.S. are passively cooled, the work focuses primarily on passive cooling, with an emphasis on the limitations of axial heat spreading within the cable. To date, literature on axial spreading of high incident heat loads on cables and cable environments is limited, typically reporting cases with <10 W of incident heat load. This work will explore the considerations, limits, and tradeoffs of cable-embedded heat loads significantly larger than the cable losses. Both external and internal effects are modeled analytically in nondimensional terms via a Biot number analysis, allowing fundamental limits and tradeoffs to be derived. The work culminates in the design and experimental validation of a cable-embedded thermal system capable of passively dissipating 300 W of heat from a coaxial SiC mosfet switch module over a length of 20 cm, thus validating the possibility of MV cable-embedded power electronics from a thermal standpoint.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigation of Ruthenium Dissolution in Advanced Membrane Electrode Assemblies for Direct Methanol Based Fuel Cell Stacks

Dissolution of ruthenium was observed in the 80-cell stack. Duration testing was performed in single cell MEAs to determine the pathway of cell degradation. EDAX analysis on each of the single cell MEAs has shown that the Johnson Matthey commercial catalyst is stable in DMFC operation for 250 hours, no ruthenium dissolution was observed. Changes in the hydrophobicity of the cathode backing papers was minimum. Electrode polarization analysis revealed that the MEA performance loss is attributed to changes in the cathode catalyst layer. Ruthenium migration does not seem to occur during cell operation but can occur when methanol is absent from the anode compartment, the cathode compartment has access to air, and the cells in the stack are electrically connected to a load (Shunt Currents). The open-to-air cathode stack design allowed for: a) The MEAs to have continual access to oxygen; and b) The stack to sustain shunt currents. Ruthenium dissolution in a DMFC stack can be prevented by: a) Developing an internally manifolded stacks that seal reactant compartments when not in operation; b) Bringing the cell voltages to zero quickly when not in operation; and c) Limiting the total number of cells to 25 in an effort to limit shunt currents.

alternative power sources↗