Search NASA⌕ Search

SEARCH · Search NASA

Results for “water absorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Airborne differential absorption lidar system for water vapor investigations

Range-resolved water vapor measurements using the differential-absorption lidar (DIAL) technique is described in detail. The system uses two independently tunable optically pumped lasers operating in the near infrared with laser pulses of less than 100 microseconds separation, to minimize concentration errors caused by atmospheric scattering. Water vapor concentration profiles are calculated for each measurement by a minicomputer, in real time. The work is needed in the study of atmospheric motion and thermodynamics as well as in forestry and agriculture problems.

Browell, E. V.↗

A comparison of methods for the measurement of the absorption coefficient in natural waters

In the spring of 1992 an optical closure experiment was conducted at Lake Pend Orielle, Idaho. A primary objective of the experiment was to compare techniques for the measurement of the spectral absorption coefficent and other inherent optical properties of natural waters. Daily averages of absorption coefficents measured using six methods are compared at wavelengths of 456, 488, and 532 nm. Overall agreement was within 40% at 456 nm and improved with increasing wavelength to 25% at 532 nm. These absorption measurements were distributed over the final 9 days of the experiement, when bio-optical conditions in Lake Pend Oreille (as indexed by the beam attenuation coefficent c(sub p)(660) and chlorophyll a fluorescence profiles) were representative of those observed throughout the experiment. However, profiles of stimulated chlorophyll a fluorescence and beam transmission showed that bio-optical properties in the lake varied strongly on all time and space scales. Therefore environmental variabilty contributed significantly to deviations between daily mean absorption coefficients measured using the different techniques.

Pegau, W. Scott↗

Solar heating, cooling and domestic hot water system installed at Columbia Gas System Service Corporation, Columbus, Ohio

The solar energy system installed in the building has 2,978 sq ft of single axis tracking, concentrating collectors and provides solar energy for space heating, space cooling and domestic hot water. A 1,200,000 Btu/hour water tube gas boiler provides hot water for space heating. Space cooling is provided by a 100 ton hot water fired absorption chiller. Domestic hot water heating is provided by a 50 gallon natural gas domestic storage water heater. Extracts from the site files, specification references, drawings, installation, operation and maintenance instructions are included.

Source record↗

Icy Galilean satellite reflectance spectra - Less ice on Ganymede and Callisto?

An evaluation of reflectance spectra of the icy Galilean satellites, taking account of the depth of the 3-micron fundamental water ice absorption feature and the shorter wavelength bands, suggests lower ice abundances for Ganymede and Callistro than previously supposed, provided that the ice is segregated from the nonicy material. Data are consistent with a 50 percent areal coverage of ice on Ganymede and 10 percent on Callistro, the rest of the surface being covered by carbonaceous chondrite-like material with strong 3-micron absorption due to bound water. The analysis indicates a homogeneous icy surface for Europa, and the possible presence on all three objects of small quantities of surface sulfuric acid.

Spencer, John R.↗

Compact Laser-Based Sensors for Monitoring and Control of Gas Turbine Combustors

Research is reported on the development of sensors for gas turbine combustor applications that measure real-time gas temperature using near-infrared water vapor absorption and concentration in the combustor exhaust of trace quantities of pollutant NO and CO using mid-infrared absorption. Gas temperature is extracted from the relative absorption strength of two near-infrared transitions of water vapor. From a survey of the water vapor absorption spectrum, two overtone transitions near 1800 nm were selected that can be rapidly scanned in wavelength by injection current tuning a single DFB diode laser. From the ratio of the absorbances on these selected transitions, a path-integrated gas temperature can be extracted in near-real time. Demonstration measurements with this new temperature sensor showed that combustor instabilities could be identified in the power spectrum of the temperature versus time record. These results suggest that this strategy is extremely promising for gas turbine combustor control applications. Measurements of the concentration of NO and CO in the combustor exhaust are demonstrated with mid-infrared transitions using thermo-electrically cooled, quantum cascade lasers operating near 5.26 and 4.62 microns respectively. Measurements of NO are performed in an insulated exhaust duct of a C2H4-air flame at temperatures of approximately 600 K. CO measurements are performed above a rich H2-air flame seeded with CO2 and cooled with excess N2 to 1150 K. Using a balanced ratiometric detection technique a sensitivity of 0.36 ppm-m was achieved for NO and 0.21 ppm-m for CO. Comparisons between measured and predicted water-vapor and CO2 interference are discussed. The mid-infrared laser quantum cascade laser technology is in its infancy; however, these measurements demonstrate the potential for pollutant monitoring in exhaust gases with mid-IR laser absorption.

Hanson, Ronald K.↗

The Galilean satellites - New near-infrared spectral reflectance measurements /0.65-2.5 microns/ and a 0.325-5 micron summary

New near-infrared (0.65-2.5 microns) reflectance spectra of the Galilean satellites are presented. These spectra more precisely define the water ice absorption features previously identified on Europa, Ganymede, and Callisto at 1.55 and 2.0 microns. In addition, previously unreported spectral features due to water ice are seen at 1.25, 1.06, 0.90, and 0.81 microns on Europa, and at 1.25, 1.04, and possibly 0.71 microns on Ganymede. Unreported absorption features in Callisto's spectrum occur at 1.2 microns, probably due to H2O, and a weak, broad band extending from 0.75 to 0.95 microns due possibly to other minerals. The spectrum of Io has only weak absorption features at 1.15 microns and between 0.8 and 1.0 microns. No water absorptions are positively identified in the Io spectra, indicating an upper limit of areal water frost coverage of 2% (leading and trailing sides). It is found for Callisto, Ganymede, and Europa that the water ice absorption features are due to free water and not to water bound or absorbed onto minerals. The areal coverage of water frost is approximately 100% on Europa (trailing side), approximately 65% on Ganymede (leading side), and 20-30% on Callisto (leading side). An upper limit of approximately 5% bound water (in addition to the 20-30% ice) may be present on Callisto, based on the strong 3-micron band seen by other investigators. A summary of spectra of the satellites from 0.325 to about 5 microns to aid in laboratory and interpretation studies is also presented.

Clark, R. N.↗

A simplified scheme for computing radiation transfer in the troposphere

A scheme is presented, for the heating of clear and cloudy air by solar and infrared radiation transfer, designed for use in tropospheric general circulation models with coarse vertical resolution. A bulk transmission function is defined for the infrared transfer. The interpolation factors, required for computing the bulk transmission function, are parameterized as functions of such physical parameters as the thickness of the layer, the pressure, and the mixing ratio at a reference level. The computation procedure for solar radiation is significantly simplified by the introduction of two basic concepts. The first is that the solar radiation spectrum can be divided into a scattered part, for which Rayleigh scattering is significant but absorption by water vapor is negligible, and an absorbed part for which absorption by water vapor is significant but Rayleigh scattering is negligible. The second concept is that of an equivalent cloud water vapor amount which absorbs the same amount of radiation as the cloud.

Katayama, A.↗

CoSSIR: A New Instrument for Exploring the Utility of Submillimeter-wave Radiometry for Earth Observation

The Conical Scanning Submillimeter-wave Imaging Radiometer (CoSSIR) has been developed to study the application of submillimeter-wave radiometry for remote sensing of cirrus clouds and humidity sounding. Measurements of the global distribution of ice cloud mass and particle size are important for understanding the Earth s energy budget and for evaluating global climate models. The spatial variability and the wide variety of cloud particle shapes and sizes make ice clouds particularly difficult to measure. Ice clouds are essentially undetectable at microwave frequencies due to the low dielectric of ice and small size of the particles relative to wavelength. However, submillimeter wavelengths demonstrate significant response to the presence of ice clouds thus this frequency regime is applicable to measuring ice clouds. Another potentially viable application for submillimeter-wave radiometry is humidity and temperature sounding. The principle of sounding at submillimeter wavelengths is similar to that at microwavelengths. Submillimeter-wave radiometry has the advantage of achieving finer spatial resolution using a smaller antenna aperture which is an important consideration for spaceborne observatories. Submillimeter-wave radiometry also offers the potential of sounding over land and as a surrogate measurement for precipitation. CoSSIR is a new instrument to explore these applications. The CoSSIR is designed to fly aboard the ER-2 aircraft and its modest size (approximately 100 kg) permits it to be configured for other aircraft. A dual-axes gimbals mechanism provides conical, across-track, and along-track scanning capability. In its present configuration CoSSIR has fifteen channels between 183 GHz and 640 GHz. Three channels are centered about the 183 GHz water vapor absorption line, four channels are centered about the 380 GHz water vapor absorption line, and three dual-polarized channels are centered about the 487 GHz oxygen absorption line. Two channels are located in atmospheric windows at 220 GHz and 640 GHz. All channels are single-linear polarized with the exception of those near 487 GHz. Calibration is achieved by periodically observing two blackbody radiators; one blackbody is heated to approximately 325 K and the other is approximately 250 K during flight. Details of the instrument design as well as measurements from the Cirrus Regional Study of Tropical Anvils and Cirrus Layers - Florida Area Cirrus Experiment will be presented.

Racette, P. E.↗

An Accurate Method for Computing the Absorption of Solar Radiation by Water Vapor

The method is based upon molecular line parameters and makes use of a far wing scaling approximation and k distribution approach previously applied to the computation of the infrared cooling rate due to water vapor. Taking into account the wave number dependence of the incident solar flux, the solar heating rate is computed for the entire water vapor spectrum and for individual absorption bands. The accuracy of the method is tested against line by line calculations. The method introduces a maximum error of 0.06 C/day. The method has the additional advantage over previous methods in that it can be applied to any portion of the spectral region containing the water vapor bands. The integrated absorptances and line intensities computed from the molecular line parameters were compared with laboratory measurements. The comparison reveals that, among the three different sources, absorptance is the largest for the laboratory measurements.

Chou, M. D.↗

Differential absorption and Raman lidar for water vapor profile measurements - A review

Differential absorption lidar and Raman lidar have been applied to the range-resolved measurements of water vapor density for more than 20 years. Results have been obtained using both lidar techniques that have led to improved understanding of water vapor distributions in the atmosphere. This paper reviews the theory of the measurements, including the sources of systematic and random error; the progress in lidar technology and techniques during that period, including a brief look at some of the lidar systems in development or proposed; and the steps being taken to improve such lidar systems.

Grant, William B.↗

Radiometric observations at 20.6, 31.65, and 90.0 GHz: Continuing studies

Ground based radiometer measurements at 20.6, 31.65, and 90.0 GHz were analyzed to provide attenuation statistics, thus extending the data base of previous NAPEX studies. Using data from colocated radiosondes, comparisons of measurements and calculations of brightness temperatures are presented. The oxygen absorption model of Rosenkranz and the water vapor absorption models of Liebe and of Waters are used. Data from July 1987 at San Nicolas Island, California and from December 1987, August and November 1988 at Denver, Colorado, are included. Joint attenuation statistics at 20.6 and 31.65 GHz are presented for two locations of the Colorado Research Network for December 1987 and August 1988.

Westwater, Ed R.↗

Environmental stability of intercalated graphite fibers

Graphite fibers intercalated with bromine, iodine monochloride, ferric chloride, and cupric chloride were subjected to stability tests under four environments which are encountered by engineering materials in the aerospace industry: ambient laboratory conditions, as would be experienced during handling operations and terrestrial applications; high vacuum, as would be experienced in space applications; high humidity, as would be experienced in marine applications; and high temperature, as would be experienced in some processing steps and applications. Monitoring the resistance of the fibers at ambient laboratory conditions revealed that only the ferric chloride intercalated fibers were unstable, due to absorption of water from the air. All four types of intercalated fibers were unstable, due to absorption of water from the air. All four types of intercalated fibers were stable for long periods under high vacuum. Ferric chloride, cupric chloride, and iodine monochloride intercalated fibers were sensitive to high humidity conditions. All intercalated fibers began to degrade above 250 C. The order of their thermal stability, from lowest to highest, was cupric chloride, iodine monochloride, bromine, and ferric chloride. Of the four types of intercalated fibers tested, the bromine intercalated fibers appear to have the most potential for application, based on environmental stability.

Gaier, J. R.↗

Environmental stability of intercalated graphite fibers

Graphite fibers intercalated with bromine, iodine monochloride, ferric chloride, and cupric chloride were subjected to stability tests under four environments which are encountered by engineering materials in the aerospace industry: ambient laboratory conditions, as would be experienced during handling operations and terrestrial applications; high vacuum, as would be experienced in space applications; high humidity, as would be experienced in marine applications; and high temperature, as would be experienced in some processing steps and applications. Monitoring the resistance of the fibers at ambient laboratory conditions revealed that only the ferric chloride intercalated fibers were unstable, due to absorption of water from the air. All four types of intercalated fibers were unstable, due to absorption of water from the air. All four types of intercalated fibers were stable for long periods under high vacuum. Ferric chloride, cupric chloride, and iodine monochloride intercalated fibers were sensitive to high humidity conditions. All intercalated fibers began to degrade above 250 C. The order of their thermal stability, from lowest to highest, was cupric chloride, iodine monochloride, bromine, and ferric chloride. Of the four types of intercalated fibers tested, the bromine intercalated fibers appear to have the most potential for application, based on environmental stability.

Gaier, J. R.↗

Retrieval of water vapor mixing ratios from a laser-based sensor

Langley Research Center has developed a novel external path sensor which monitors water vapor along an optical path between an airplane window and reflective material on the plane's engine. An infrared tunable diode laser is wavelength modulated across a water vapor absorption line at a frequency f. The 2f and DC signals are measured by a detector mounted adjacent to the laser. The 2f/DC ratio depends on the amount of wavelength modulation, the water vapor absorption line being observed, and the temperature, pressure, and water vapor content of the atmosphere. The present work concerns efforts to quantify the contributions of these factors and to derive a method for extracting the water vapor mixing ratio from the measurements. A 3 m cell was fabricated in order to perform laboratory tests of the sensor. Measurements of 2f/DC were made for a series of pressures and modulation amplitudes. During my 1994 faculty fellowship, a computer program was created which allowed 2f/DC to be calculated for any combination of the variables which effect it. This code was used to generate 2f/DC values for the conditions measured in the laboratory. The experimental and theoretical values agreed to within a few percent. As a result, the laser modulation amplitude can now be set in the field by comparing the response of the instrument to the calculated response as a function of modulation amplitude. Once the validity of the computer code was established, it was used to investigate possible candidate absorption lines. 2f/DC values were calculated for pressures, temperatures, and water vapor mixing ratios expected to be encountered in future missions. The results have been incorporated into a database which will be used to select the best line for a particular mission. The database will also be used to select a retrieval technique. For examples under some circumstances there is little temperature dependence in 2f/DC so temperature can be neglected. In other cases, there is a dependence with temperature for a particular pressure, requiring a more complicated retrieval algorithm. Future experimental work is necessary to test agreement with the theoretical values over a range of temperatures and mixing ratios. Additionally, retrieval algorithms for forthcoming missions must be incorporated into the software package which controls the instrument.

Tucker, George F.↗

Atmospheric transmission coefficients for laser pulses with spectral widths of a few tenths of a nanometer over the wavelength region from 800 to 860 nanometers

Effective atmospheric transmission spectra were calculated from 800 to 860 nanometers for laser sources with spectral widths of a few tenths of a nanometer. In this spectral region, the atmospheric absorption lines (water lines) have linewidths of a few hundredths of a nanometer, so that the transmission coefficient for a relatively wide laser pulse must be computed by taking a weighted average over the pulse spectral width. Laser spectral widths of several tenths of a nanometer are shown to reduce the effective absorption by water lines to as little as 10 to 20 percent, even when the laser is centered on a line or overlaps several lines. Thus, the effect of absorption by atmospheric water lines may be greatly reduced for laser communication systems using laser diode array transmitters, for which the pulse spectral width may be a few tenths of a nanometer.

Safren, H. G.↗