Search NASA⌕ Search

SEARCH · Search NASA

Results for “water heaters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Pool Boiling Reliability Tests and Degradation Mechanisms of Microporous Copper Inverse Opal (CuIOs) Structures

The rising power density in electronic systems requires thermal management solutions that are both high-performing and reliable. Porous materials such as Copper Inverse Opal (CuIOs) have unique structural features, including high permeability and high thermal conductivity, to enhance pool boiling performance. However, there is little understanding of the degradation mechanism of such porous materials under pool boiling conditions. In this study, samples of 10 ..mu..m thick CuIOs with 4.8 ..mu..m diameter, covering silicon substrate of area 11 mm x 11 mm, with various heated areas ranging from 2.5 mm x 2.5 mm to 10 mm x 10 mm, were tested in 100 degrees C deionized water at a constant heat flux of 110 Wcm -2 for 3-to-7 days. The combined effect of erosion and corrosion caused structural degradation of the CuIOs. The directly heated area had the most severe degradation while the edge of the heater and the unheated area showed progressively less degradation, maintaining some CuIOs structure even after the 7-day reliability test. Among all the tested samples with various heater sizes, the 2.5 mm x 2.5 mm heater sample - in which the heater size was designed to be comparable to the water bubble characteristic length - had the largest critical heat flux (CHF) up to 300 Wcm -2 with a superheat ~ 13 degrees C. Additionally, CuIOs with a smaller heated area performed better in terms of reliability. This study offers preliminary insights into CuIOs degradation mechanisms, contributing to the development of more robust thermal management solutions. We expect that electroless plating of CuIOs with gold (Au), nickel (Ni), and atomic layer deposition (ALD) aluminum oxide (Al 2 O 3 ) in combination with appropriate application-specific coolants will further improve the reliability and lifetime of the CuIOs.

boiling-induced degradation↗

Pool Boiling Reliability Tests and Degradation Mechanisms of Microporous Copper Inverse Opal (CuIOs) Structures: Preprint

The rising power density in electronic systems requires thermal management solutions that are both high-performing and reliable. Porous materials such as Copper Inverse Opals (CuIOs) have unique structural features, including high permeability and high thermal conductivity, to enhance pool boiling performance. However, there is little understanding of the degradation mechanism of such porous materials under pool boiling conditions. In this study, samples of 10-micrometer-thick CuIOs with 4.8-micrometer diameter, covering silicon substrate of area 11-mm by 11-mm, with various heated areas ranging from 2.5-mm by 2.5-mm to 10-mm by 10-mm, were tested in 100 degrees C deionized water at a constant heat flux of 110 watts per square cm for 3-7 days. The combined effect of erosion and corrosion caused structural degradation of the CuIOs. The directly heated area had the most severe degradation while the edge of the heater and the unheated area showed progressively less degradation, maintaining some CuIOs structure even after the 7-day reliability test. Among all the tested samples with various heater sizes, the 2.5-mm by 2.5-mm heater sample - in which the heater size was designed to be comparable to the water bubble characteristic length - had the largest critical heat flux (CHF) up to 300 watts per square cm with a superheat of approximately 13 degrees C. Additionally, CuIOs with a smaller heated area performed better in terms of reliability. This study offers preliminary insights into CuIOs degradation mechanisms, contributing to the development of more robust thermal management solutions. We expect that electroless plating of CuIOs with gold (Au), nickel (Ni), and atomic layer deposition of aluminum oxide in combination with appropriate application-specific coolants will further improve the reliability and lifetime of the CuIOs.

boiling-induced degradation↗

Investigation of Abnormal Level Control Oscillations in a BWR Feedwater System

In the long-term operation of nuclear power plants, the aging of systems, structures, and components can lead to maintenance issues that must be dealt with to maintain cost-effective plant operations. One common issue affecting the currently operated boiling water reactors is the onset of unexpected level oscillations in feedwater heaters. This phenomenon can cause excessive cycling of drain valves and lead to premature failures. In this work, we develop a dynamic model of a set of feedwater heaters to determine the root cause of oscillations observed in an operating plant. Simulation results of various transient scenarios were used to investigate the effects of the controller parameters, boundary conditions, and possible valve and instrument issues. The analysis led to the conclusion that the most likely causes of the observed self-sustained oscillations in the system are the nonlinear behaviors of the drain valve and the level transmitter induced by degraded equipment condition. In conclusion, a partial plug of the pressure line used for level sensing in the system can account for a significant deadtime in the level transmitter, a nonlinear effect shown to induce self-sustained oscillatory behaviors.

Boiling water reactors↗

Temperature response and brine availability to heated boreholes in bedded salt

Abstract There is a growing need for disposal of high‐level nuclear waste. To reduce uncertainty associated with brine availability to repository excavations in salt formations, a collaboration between Sandia, Los Alamos, and Lawrence Berkeley National Laboratories is performing a series of borehole‐scale coupled process tests. Here, we report on the first round of the Brine Availability Test in Salt (BATS) project, a “shakedown” experiment called Phase 1s. Experimental testing included placing a resistive heater, a 260‐W radiative heater, and a 750‐W radiative heater within previously drilled horizontal boreholes at the Waste Isolation Pilot Plant (WIPP) while monitoring temperature and water inflow. The experiments successfully achieved the targeted temperature of 120 °C when using the 750‐W radiative heater. Simulations using FEHM (Finite Element Heat and Mass transfer code) and TOUGH‐FLAC (Transport Of Unsaturated Groundwater and Heat–Fast Lagrangian Analysis of Continua) were able to accurately predict the coupled thermo–hydro–mechanical–chemical response of salt, matching the observed temperature and brine production. Due to the extremely low permeability of salt, these systems take many years to reach steady state when perturbed by mining activities. Long‐term numerical simulations are used to develop the initial pressure and saturation conditions. The inclusion of a damaged rock zone with higher permeability around the borehole also affects the saturation and pressure distributions and plays an important role in dissipating the potential for thermal pressurization. Knowledge gained from this round of experimentation and simulation will be used to conduct the next BATS project experiment in new boreholes at WIPP.

58 GEOSCIENCES↗

Critical heat flux on zircaloy and accident tolerant fuel cladding under prototypical conditions of pressurized and boiling water reactors

First of a kind high spatial and temporal resolution temperature measurements of Pressurized Water Reactor and Boiling Water Reactor simulated fuel pins (high heat flux cosine profile heaters) in annular rod type geometry during nucleate boiling, departure from nucleate boiling and re-wetting has been performed. Distributed fiber optic measurements of the cladding axial temperature with spatial resolutions down to 2.5 mm axially at up to three equally spaced azimuthal locations per rod have demonstrated the similarities and differences of the different accident tolerant fuel cladding materials. These experiments show the performance of accident tolerant cladding with a precise measurement of the location and evolution of dryout followed by the re-wetting phenomena (see supplementary time history of a critical heat flux event). Experimental parameters varied coolant mass fluxes from 1695 to 2712 kg/m 2 s, pressures from 10 to 20 MPa, and inlet subcooling from 10 to 55 °C. It was found that the coatings and different material have little effect on the value of the critical heat flux. Any discrepancies between the local critical heat flux verified among the cladding material are attributed to different departure from nucleate boiling phenomena captured during the experiment with the high-resolution optical fiber temperature data. Substantial differences in the performance of the different cladding material to survive a critical heat flux event were however observed by post-test X-ray and optical inspection. External evident damage and internal cracks to the simulated fuel pin having the bare zircaloy cladding were observed in regions associated with the occurrence of the critical heat flux for longer periods. Such damages were associated with zirconium oxidation, and not noticed on the Cr coated zircaloy or FeCrAl claddings. These results indicate that the use of FeCrAl or a Cr coated zircaloy as cladding in Pressurized Water Reactor and Boiling Water Reactor may increase the survivability of the cladding material for short transients.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Physical Modeling of Coupled Thermohydraulic Behavior of Compacted MX80 Bentonite during Heating

Abstract This paper describes a tank-scale test setup and experimental methodology used to investigate coupled heat transfer and water flow processes during heating of compacted MX80 bentonite to high temperatures. Specifically, a temperature of 200°C was maintained by a cylindrical heating element at the center of a compacted bentonite layer containing an array of temperature, dielectric, and relative humidity sensors. In addition to providing an evaluation of the spatiotemporal variations in temperature, relative humidity, degree of saturation, and global volume, the coupled thermohydraulic properties of the bentonite were assessed. A wetting front was initially observed to move away from the central heater, followed by a drying process until reaching thermohydraulic equilibrium. The soil–water retention curve (SWRC) of the bentonite followed a wetting scanning path before following the primary drying path exhibiting a shift in water retention with elevated temperature. Results from the tank-scale test can be used for validation of numerical simulations of drying processes in the engineered barrier system of a high-level radioactive waste geological disposal repository and confirm that a temperature-dependent hysteretic SWRC with scanning paths is required to accurately capture the bentonite response.

Engineering↗

Uranium Oxide Elutriation at Higher Flow Rates and Longer Times

This work supports the recovery of high-assay low-enriched uranium (i.e., U enriched in 235 U to >5% and <20%) from used nuclear fuel. One step includes elutriating triuranium octoxide (U 3 O 8 ) from a fluidized bed of alumina (Al 2 O 3 ) that fills the main reaction chamber. The experiments outlined in this report assessed the effects of the time and flow rate on the elutriation of U 3 O 8 powder from the reaction vessel. Testing at Oak Ridge National Laboratory (ORNL) was performed in a one-fourth scale experimental apparatus based on a pilot-scale system, which is the Material Recovery Pilot Plant (MRPP) at Idaho National Laboratory (INL). The experimental system comprises a supply of pressurized nitrogen (N 2 ), a gas heater, the reaction vessel, a knock-out pot, and a water trap where elutriated particles are collected for sampling. An Al 2 O 3 fluidized bed is contained within the reaction vessel. A bed of Al 2 O 3 with a nominal size of 180 µm and U 3 O 8 with a nominal size of 7 µm was fluidized at 2 different flow rates so the U 3 O 8 physically separated from the bed. The apparatus was simple and had no valves or sharp bends downstream from the reactor. The flow exited the reactor through a side port at the top. The flow passed through a knock-out vessel before the flow was passed through a bubbler to capture the U 3 O 8 . Seven tests were completed with U 3 O 8 using an elutriating gas of N 2 heated to 200°C. Tests were performed with bed loadings that comprise 25.0 g of U 3 O 8 , or 3.6 wt% of the bed mass. Except for one test performed at 12 SLPM, the gas flow rate through the bed for the other experiments was set at 10 SLPM as measured by the mass flow meter. Linear velocities through the bed were calculated as 28 and 34 cm/s, or 0.9 and 1.1 ft·s -1 . The duration of the tests ranged from 20 to 180 min, and one test had a flow cycled between 0 and 5 SLPM every 5 min for 40 min. The testing successfully demonstrated elutriation of U 3 O 8 from the fluidized bed as up to a 100% of the U 3 O 8 was transferred out of the bed. The removal of U 3 O 8 had a logarithmic dependence on flow rate. The design changes made the apparatus easier to clean, and the mass balances were better than those used in previous studies. Some elutriated Al 2 O 3 collected in the tubing that connected the reactor to the knock-out pot, but the amount of Al 2 O 3 was minimal for 10 SLPM. The flow at 12 SLPM showed considerable transport of Al 2 O 3 bed material into the reaction-vessel headspace and the transfer line to the knock-out pot.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advanced Drying Cycle Simulator Thermal Response to Commercial Drying Conditions

The purpose of this report is to document updates on testing of the apparatus built to simulate commercial drying procedures for spent nuclear fuel at the Nuclear Energy Work Complex at Sandia National Laboratories. Validation of the extent of water removal in a dry spent nuclear fuel storage system based on drying procedures used at nuclear power plants is needed to close existing technical gaps. Operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system during subsequent storage and disposal. A general lack of data suitable for model validation of commercial nuclear canister drying processes necessitates well-designed investigations of drying process efficacy and water retention that incorporate relevant physics and well-controlled boundary conditions. This report documents testing updates for the Advanced Drying Cycle Simulator (ADCS). This apparatus was built to simulate commercial drying procedures and quantify the amount of residual water remaining in a pressurized water reactor (PWR) fuel assembly after drying. The ADCS was constructed with a prototypic 17×17 PWR fuel skeleton and waterproof heater rods to simulate decay heat. These waterproof heaters are the next generation design to heater rods developed and tested at Sandia National Laboratories in FY20. This report describes preliminary testing of the ADCS through measurement and analysis of the thermal response of the system to a subset of commercial drying conditions that exclude the introduction of water, namely simulated decay heats and pressures relevant to commercial drying. This test series, referred to as a “dry” test series in this report, spans three uniform waterproof heater rod powers (representing spent fuel decay heats), four helium fill pressures, and six vacuum levels. This test series was conducted to cover the range of expected ADCS testing conditions for upcoming “wet” testing, where water will be introduced and a simulated commercial drying cycle will be performed. The dry test conditions were derived from the commercial drying conditions seen in the High Burnup Demonstration and the vacuum drying conditions chosen for a smaller scale Dashpot Drying Apparatus tested at Sandia National Laboratories in FY22. For a given uniform power and pressure/vacuum level, the ADCS was operated at constant power and pressure and allowed to reach steady state conditions. The thermal data obtained from these tests were analyzed, and the results can inform computational models built to simulate commercial drying processes by providing baseline thermal data prior to the introduction of water. Following the preliminary dry tests, a test plan for the ADCS will be developed to implement a drying procedure that begins with the introduction of water to the system and is based on measurements from the drying process used for the High Burnup Demonstration Project. While applying power to the simulated fuel rods, this procedure is expected to consist of filling the ADCS vessel with water, draining the water with applied pressure and multiple helium blowdowns, evacuating additional water with a vacuum drying sequence at successively lower pressures, and backfilling the vessel with helium. Additional investigations are expected to feature failed fuel rod simulators with engineered cladding defects and guide tubes with obstructed dashpots to challenge the drying system with multiple water retention sites. The data from these investigations is expected to inform the efficacy of commercial drying operations through the quantification of residual water in a prototypic-length dry storage canister.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development & Experimental Validation of a Generalized Resistance-Capacitance Model for Numerical Simulation of Phase-Change Material Embedded Heat Exchangers

Latent heat thermal energy storage (LHTES) using phase change material (PCM) has attracted increased attention as a viable solution for overcoming the mismatch between energy supply and demand for renewable energy-based systems. PCM-embedded heat exchangers (PCM-HX) have the potential to significantly improve thermal performance due to high storage capacity and low temperature variation during the phase change process. Most models for simulating LHTES heat transfer use Computational Fluid Dynamics (CFD) simulations, which have high computational costs resulting from considering the complex and time-dependent physics relevant to PCM-HXs. In this paper, a Generalized Resistance Capacitance-based Model (GRCM) was developed to predict the thermal performance of arbitrary PCM-HXs in a computationally efficient manner without compromising modeling accuracy. The GRCM is exercised for three case studies: (i) verification for a single-slabbed finned PCM-HX, (ii) verification and validation for a copper foam/paraffin composite PCM-HX, and (iii) validation for a straight tube annular finned PCM-HX. The copper foam PCM-HX uses an electric heater at the top of HX, while the other two configurations utilize water as heat transfer fluid. For the single-slabbed finned PCM-HX melting case, the mean deviation in average PCM temperature predicted by the GRCM compared to the CFD model was between 0.56 – 0.73 K, with maximum temperature deviation of 2.68 K. For the HTF outlet temperature, the validation results showed that GRCM prediction matches very well with experimental data, with mean temperature deviation of 0.24 K during melting case, while for solidification case was 0.34 K. These results showcase the GRCM’s capability for accurately reproducing the thermal characteristics of PCM-HXs with considerably lower computational effort.

42 ENGINEERING↗

Warming of alpine tundra enhances belowground production and shifts community towards resource acquisition traits

Abstract Climate warming is expected to stimulate plant growth in high‐elevation and high‐latitude ecosystems, significantly increasing aboveground net primary production (ANPP). However, the effects of simultaneous changes in temperature, snowmelt timing, and summer water availability on total net primary production (NPP)—and elucidation of both above‐ and belowground responses—remain an important area in need of further study. In particular, measures of belowground net primary productivity (BNPP) are required to understand whether ANPP changes reflect changes in allocation or are indicative of a whole plant NPP response. Further, plant functional traits provide a key way to scale from the individual plant to the community level and provide insight into drivers of NPP responses to environmental change. We used infrared heaters to warm an alpine plant community at Niwot Ridge, Colorado, and applied supplemental water to compensate for soil water loss induced by warming. We measured ANPP, BNPP, and leaf and root functional traits across treatments after 5 yr of continuous warming. Community‐level ANPP and total NPP (ANPP + BNPP) did not respond to heating or watering, but BNPP increased in response to heating. Heating decreased community‐level leaf dry matter content and increased total root length, indicating a shift in strategy from resource conservation to acquisition in response to warming. Water use efficiency (WUE) decreased with heating, suggesting alleviation of moisture constraints that may have enabled the plant community to increase productivity. Heating may have decreased WUE by melting snow earlier and creating more days early in the growing season with adequate soil moisture, but stimulated dry mass investment in roots as soils dried down later in the growing season. Overall, this study highlights how ANPP and BNPP responses to climate change can diverge, and encourages a closer examination of belowground processes, especially in alpine systems, where the majority of NPP occurs belowground.

54 ENVIRONMENTAL SCIENCES↗

DECOVALEX-2023: Task D Final Report

Task D of DECOVALEX-2023 is focused on the simulation of the coupled thermal hydraulic-mechanical (THM) behaviour in the full-scale engineered barrier system (EBS). The Horonobe EBS experiment is the demonstration of the full-scale EBS in the underground research laboratory (URL) (performed by JAEA in the Horonobe URL in Japan). Task D consisted of the three steps, a preliminary step (Step 0), simulation of the laboratory tests (Step 1) and simulation of the in-situ full-scale EBS experiment (Step 2). Since the Horonobe EBS experiment demonstrates the vertical emplacement option of the EBS, the experiment gallery is also backfilled with the backfill material. Therefore, interaction between the EBS and the backfill material can also be demonstrated, such as deformation (change of density) of the buffer material. The underground water in the Horonobe URL is saline. This fact adds chemical processes to THM behaviour. For example, mechanical properties (such as swelling pressure of the buffer material and backfill material) and hydraulic properties (such as permeability of the buffer material and backfill material) change depending on the water chemistry. Task D was therefore a challenging Task focused on not only the relatively simple THM behaviour but also complex THM behaviour including chemical processes. Six research teams (BGR, CAS, JAEA, KAERI, SNL and Taipower) participated the Task D. BGR, CAS, JAEA, KAERI and Taipower research teams selected a THM approach, while the SNL research team selected a TH approach. Step 1 involved the simulation of laboratory test results and was important to check the numerical codes developed by the research teams. Step 1 was divided into four sub steps. The simulation results through the Step 1 identified the parameters for simulation of the Step 2. Basic parameters of the materials (buffer material, backfill material, rock mass, concrete, sand) were provided by JAEA. Special parameters which research team needed were identified by back analysis of Step 1. Most notably the mechanical behaviour of swelling and displacement depended on the applied model (elastic model or elastoplastic model). Parameters such as Young’s modulus were found to need smaller values than characterised in the fundamental laboratory test results (Step 1-1, 1-2) for the elastic model. Although laboratory experiments are usually simple, test results contained some error. For example, if the saturation level is 100 % or higher, it should be considered an error. This situation was presented in the Step 1-3. A possible reason is that the buffer material is a mixture of bentonite and silica sand. When a specimen is cut to measure volume or weight, sand grains will affect the measurement data. In Step 2, boundary conditions such as temperature on the surface of the simulated overpack, heater power of the electrical heaters installed in the simulated overpack, injection pressure and inflow rate of the test water, were applied. The outer boundary conditions can be selected using measured data (injection pressure and inflow rate of the test water that is controlled by the injection systems installed in the sand layer around the buffer material and in the boundary between backfill material and concrete support). Since such measured data has some noise, research teams developed their own simplified boundary conditions. Inner boundary conditions can be selected using measured data as heater power and temperature on the surface of the simulated overpack. These data also contain some noise, so research teams developed their own simplified developed boundary conditions. Task D validated various approaches thorough the simulation of the in-situ full scale EBS system including backfill of the gallery: variations in the coupling processes (THM or THC), analysis codes, and boundary conditions. Temperature distribution in the buffer material was simulated well by all research teams. This means thermal behaviour is not sensitive to the simulation approaches. Although the water content distribution on the outside of the buffer material was well simulated by all research teams, the simulation results differ from the measured values inside the buffer material (at the centre and inside, near the simulated overpack). The buffer material is made from tap water, but in the in-situ experiment, saline groundwater infiltrates the buffer material. Therefore, the selection of the hydraulic parameters of the buffer material greatly affects the simulation results of the re saturation behaviour of the buffer material. In the Horonobe EBS experiment, measured values suitable for validating the simulation results were not obtained near the simulated overpack. When simulating the pressure and deformation of the buffer material, the measurement data is easily affected by the installation conditions of the measurement sensors, so verifying the measurement data itself remains an issue. Mechanical simulation results differ depending on whether they are considered as elastic or elastoplastic phenomena. The accuracy of measured in-situ data can be assessed by detailed analysis comparing sampling specimen analysis and measured data. The Horonobe EBS experiment is scheduled to be dismantled in the future (FY2026 and 2027). This detailed dismantling investigation will finally confirm the measured data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Data from: "Warming of alpine tundra enhances belowground production and shifts community towards resource acquisition traits"

This archive contains data used to draw conclusions in “Warming of alpine tundra enhances belowground production and shifts community towards resource acquisition traits”, by Yang et al. 2020. Data were collected on Niwot Ridge, in an alpine meadow within the Alpine Treeline Warming Experiment (ATWE) field sites in Colorado, USA. Samples were also processed in the U.S. Geological Survey Forest and Rangeland Ecosystem Science Center, in Boise, Idaho. File formats in this archive include comma-separated values (.csv), portable document format (.pdf), Microsoft Excel (.xlsx), and two types of geospatial files: keyhole markup language (.kml), and ESRI shapefiles (.shp). Leaf scans are .jpg images, and root scans are .tiff/.tif images.The .csv files can be opened using R, Microsoft Excel, or any simple text-editing software such as TextEdit and Notepad. Microsoft Excel files can be opened using Microsoft Excel, and .pdf files can be opened with Adobe Acrobat Reader, Preview, or other compatible programs. Scanned images can be opened using any photo and/or picture viewing software.The .kml file can be opened using Google Earth and Google Maps, and the shapefiles can be opened by any programs compatible with shapefiles, such as the ArcGIS Desktop suite, and QGIS.------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------Measures of belowground net primary productivity (BNPP) are required to understand whether aboveground net primary production (ANPP) changes reflect changes in allocation or are indicative of a whole plant NPP response. Plant functional traits provide a key way to scale from the individual plant to the community level, and provide insight into drivers of NPP responses to environmental change. We used infrared heaters to warm an alpine plant community at Niwot Ridge, Colorado, and applied supplemental water to compensate for soil water loss induced by warming. We measured ANPP, BNPP, and leaf and root functional traits across treatments after 5 years of continuous warming. Community-level ANPP and total NPP (ANPP + BNPP) did not respond to heating or watering, but BNPP increased in response to heating. Heating decreased community-level leaf dry matter content and increased total root length, indicating a shift in strategy from resource conservation to acquisition in response to warming.

13C/12C isotope ratio↗

Systems and methods for water desalination using thermo-responsive ionic liquids regenerated by solar energy

This disclosure provides systems, methods, and apparatus related to water desalination. In one aspect, a method includes generating a diluted draw solution using forward osmosis. Wastewater is on a first side of an osmotic membrane and a draw solution is on a second side of the osmotic membrane. The draw solution comprises a mixture of water and an ionic liquid. Water in the wastewater diffuses across the osmotic membrane to the draw solution to form the diluted draw solution. The diluted draw solution is heated using a photonic heater to a temperature above a lower critical solution temperature (LCST) of the ionic liquid to phase separate the diluted draw solution into the ionic liquid and treated water.

Kostecki, Robert↗

Data from: "Warming and the dependence of limber pine (Pinus flexilis) establishment on summer soil moisture within and above its current elevation range"

This data package contains data that were used for analysis in “Warming and the dependence of limber pine (Pinus flexilis) establishment on summer soil moisture within and above its current elevation range”, by Moyes et al. 2013. All data collection and field research were completed on Niwot Ridge, Colorado, USA.This data package contains nine comma-separated-values (.csv) files, one text (.txt) file, and two zipped seedling folders that were used for leaf area analysis. One zipped folder contains 468 .jpg photographs of seedlings, and the second contains 468 corresponding Image J-processed .jpg images that include silhouette leaf area values. .csv and .txt files can be opened using any compatible simple text-editor software such as TextEdit (Mac) and Notepad (Windows); .csv’s can also be opened using R and Microsoft Excel. Image files can be opened using Preview (Mac) and Photos (Windows). In addition, there are a total of 31 Microsoft Excel files: three .xlsx files, and 28 raw Li-Cor output .xls files. This data user’s guide is available in .pdf format, and can be opened using Adobe Acrobat Reader, or any other compatible file viewing software. Geospatial data showing field site locations are also included in the archive for use and reference. There are two geospatial formats in this archive: ESRI shapefiles (.shp) and keyhole markup-language (.kml) files. Both file types contain bounding box information, with the former being polygons, and the latter containing corner coordinates for each site. ESRI shapefiles can be opened using any geospatial software compatible with the file type (such as ESRI’s ArcGIS suite and QGIS), and .kml files are compatible with Google Earth and Google Maps.--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------Continued changes in climate are projected to alter the geographic distributions of plant species, in part by affecting where individuals can establish from seed. We tested the hypothesis that warming promotes uphill redistribution of subalpine tree populations by reducing cold limitation at high elevation and enhancing drought stress at low elevation. We seeded limber pine (Pinus flexilis) into plots with combinations of infrared heating and water addition treatments, at sites positioned in lower subalpine forest, the treeline ecotone, and alpine tundra. In 2010, first-year seedlings were assessed for physiological performance and survival over the snow-free growing season. Seedlings emerged in midsummer, about 5–8 weeks after snowmelt. Low temperature was not observed to limit seedling photosynthesis or respiration between emergence and October, and thus experimental warming did not appear to reduce cold limitation at high elevation. Instead, gas exchange and water potential from all sites indicated a prevailing effect of summer moisture stress on photosynthesis and carbon balance. Infrared heaters raised soil growing degree days (base 5 °C, p < 0.001) and August–September mean soil temperature (p < 0.001). Despite marked differences in vegetation cover and meteorological conditions across sites, volumetric soil moisture content (θ) at 5–10 cm below 0.16 and 0.08 m^3 m^(−3) consistently corresponded with moderate and severe indications of drought stress in midday stem water potential, stomatal conductance, photosynthesis, and respiration. Seedling survival was greater in watered plots than in heated plots (p = 0.01), and negatively related to soil growing degree days and duration of exposure to θ < 0.08 m^3 m^(−3) in a stepwise linear regression model (p < 0.0001). We concluded that seasonal moisture stress and high soil surface temperature imposed a strong limitation to limber pine seedling establishment across a broad elevation gradient, including at treeline, and that these limitations are likely to be enhanced by further climate warming.--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------Maintenance log:Amended file name error in Data User's Guide May 19 2022

54 ENVIRONMENTAL SCIENCES↗

Mitigating Electrochemical Impedance Spectroscopy Artifacts in PEMWE Reference Electrode Measurements

This study investigates strategies to improve the quality of electrochemical impedance spectroscopy (EIS) measurements using reference electrodes (RE) in proton exchange membrane water electrolyzers (PEMWE). We demonstrate that adding a low impedance wire in parallel to the RE significantly enhances signal accuracy, especially at high frequencies. Additionally, we identify electrical pad heaters as a source of measurement noise. EIS measurements fulfilling Kramers–Kronig validity criteria were only achieved in their absence. These insights advance the diagnostic capabilities of REs in water electrolyzers and support more reliable, spatially resolved analysis of electrochemical losses within the cell.

08 HYDROGEN↗

Preliminary Simulations of Commercial Drying Cycles Using the Advanced Drying Cycle Simulator

The purpose of this report is to document updates on the apparatus to simulate commercial vacuum drying procedures at the Nuclear Energy Work Complex at Sandia National Laboratories. Validation of the extent of water removal in a dry spent nuclear fuel storage system based on drying procedures used at nuclear power plants is needed to close existing technical gaps. Operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system during subsequent storage and disposal. A general lack of data suitable for model validation of commercial nuclear canister drying processes necessitates well-designed investigations of drying process efficacy and water retention. Scaled tests that incorporate relevant physics and well-controlled boundary conditions are essential to provide insight and guidance to the simulation of prototypic systems undergoing drying processes. This report documents fiscal year 2023 (FY23) updates on the Advanced Drying Cycle Simulator (ADCS). This apparatus was built to simulate commercial drying procedures and quantify the amount of residual water remaining in a pressurized water reactor (PWR) fuel assembly after drying. The ADCS was constructed with a prototypic 17×17 PWR fuel skeleton and waterproof heater rods to simulate decay heat. These waterproof heaters are the next generation design to heater rods developed and tested at Sandia National Laboratories in FY20. In FY23, a series of four simulated commercial drying tests was completed. This report presents the temperature and pressure histories of the drying tests as well as axial temperature profiles that can be compared to data from the Electric Power Research Institute (EPRI) High Burnup Demonstration TN-32B cask. Water content measurements and dew point calculations from a Hiden Analytical HPR-30 mass spectrometer are also presented in this report. Due to familiarization with this first-of-a-kind system, refinements to equipment calibration and test procedures have been identified to better match commercial drying cycles for future simulated tests. However, the presented data demonstrate the successful construction and operation of a viable research platform for quantifying residual water content closely approaching that expected in dry storage canisters during commercial drying procedures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantification of Residual Water in Spent Fuel Dry Storage Canisters Using Mass Spectrometry

The purpose of this report is to document updates on the apparatus to simulate commercial vacuum drying procedures at the Nuclear Energy Work Complex at Sandia National Laboratories. Validation of the extent of water removal in a dry spent nuclear fuel storage system based on drying procedures used at nuclear power plants is needed to close existing technical gaps. Operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system during subsequent storage and disposal, such as fuel degradation; cladding corrosion, embrittlement, or breaching; and the creation of a flammable environment via radiolysis of water. A general lack of data suitable for model validation of commercial nuclear canister drying processes necessitates well-designed investigations of drying process efficacy and water retention. Scaled tests that incorporate relevant physics and well-controlled boundary conditions are essential to provide insight and guidance to the simulation of prototypic systems undergoing drying processes. This report documents details on the quantification of residual water in the Advanced Drying Cycle Simulator (ADCS), an apparatus built to simulate commercial drying procedures and quantify the amount of residual water remaining in a pressurized water reactor (PWR) fuel assembly after drying. The ADCS was constructed with a prototypic 17×17 PWR fuel skeleton and waterproof heater rods to simulate decay heat. The ADCS is outfitted with thermocouples to measure the thermal response of the ADCS to simulated decay heats and internal helium fill pressures relevant to commercial drying procedures. The ADCS is also instrumented with pressure transducers to measure the pressures and vacuum levels observed during simulated commercial drying. The most unique instrumentation used for quantifying residual water in the ADCS is a Hiden Analytical HPR-30 mass spectrometer (MS), which measures gas compositions of the ADCS internal free volume, based on partial pressures calculated from relative proportions of gas molecules detected by the MS. This report details the methodology used to implement MS measurements in quantifying residual water in the ADCS. This methodology includes the calibration of the HPR-30 MS to a Buck Research Instruments CR-4 chilled mirror hygrometer, which itself is calibrated to a NIST-traceable standard. Data collected by both the MS and the chilled mirror hygrometer from water/helium mixtures ranging from 150 to 500,000 ppmv water in helium were used to generate calibration curves, establishing a source of verification of MS measured water contents. Details regarding water content measurement uncertainties are included in this report, defining the accuracy and verifiability of the HPR-30 MS in measuring residual water content in simulated dry storage canister environments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Flow and Heat Transfer Experimental Study for 3D-Printed Solar Receiving Tubes With Helical Fins at Internal Surface

3D-printing technology was applied to fabricate novel solar thermal collection tubes that have internal heat transfer enhancement fins and external surfaces with high solar absorptivity and low emissivity due to the ability to use different materials in one tube. Helical fins were selected to introduce circumferential flow and thus minimize the circumferential temperature difference of the tube that receives sunlight on one side. The structures of the helical fins were previously optimized from computational fluid dynamics (CFD) analysis with the objective of low entropy production rate by looking for high heat transfer coefficient and relatively lower pressure loss. High-temperature alloy, Inconel-718, was used to 3D print the tubes, which can resist corrosion for the potential application of molten chloride salts as heat transfer fluid. Experimental tests were carried out using water as the heat transfer fluid with the high heat flux provided by a tubular furnace heater. The tested Reynolds number ranges from 3.9 × 10 3 to 6.1 × 10 4 . Heat transfer coefficients of up to 2.8 times that of the smooth tube could be obtained with the expense of increased pressure loss compared to that of the smooth tube. The total system entropy generation can be significantly reduced due to the benefit of heat transfer enhancement that is greater than the expenses of the increased pressure loss. The experimental results of the 3D-printed heat transfer tubes confirmed the CFD-based results of fin optimization. Furthermore, the novel heat transfer tube is recommended for application in concentrating solar power systems.

14 SOLAR ENERGY↗