Search NASA⌕ Search

SEARCH · Search NASA

Results for “water temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Modular SOEC System for Efficient H 2 Production at High Current Density

The overall objective of the project was to demonstrate the potential of Solid Oxide Electrolysis Cell (SOEC) systems to produce hydrogen at a cost of $\$$2.00/kg H 2 or less (excluding delivery, compression, storage, and dispensing). An additional objective of the project was to enhance Solid Oxide Electrolysis Cell (SOEC) stack endurance and impart subsystem robustness for operation on load profiles compatible with intermittent renewable energy sources. The project was designed to achieve the overall objectives through a multi-disciplinary approach that included SOEC stack and materials development, systems development and optimization, techno-economic analyses, and ultimately the demonstration of a > 4 kg H 2 /day SOEC system. The scope of work included research and development efforts to develop an advanced, high temperature, water splitting (HTWS) system with superior performance and durability relative to the current state-of-the-art. In support of the aforementioned goals, the project activities included: 1) Develop and test cell materials with improved endurance at high current densities; 2) Design and fabricate a >4 kg H 2 /day SOEC stack optimized for high efficiency operation in the range of 1 - 2 A/cm 2 ; 3) Perform stack testing under simulated system conditions; 4) Perform systems analysis including configuration and parametric studies, to maximize SOEC system efficiency and minimize H 2 production costs; 5) Develop the conceptual design of a >4 kg H 2 /day thermally self-sustaining SOEC demonstration system including stack module and balance of plant (BoP).

08 HYDROGEN↗

Predicting river turbidity in Pine Island Bayou using machine learning techniques coupled with variational mode decomposition

Elevated turbidity levels pose significant public health risks by facilitating the transport of harmful pollutants, including metals, organic compounds, and pathogenic microorganisms into the surface water. These conditions create serious challenges for public recreational water use and drinking water treatment, leading to economic losses and health risks. This study utilizes water monitoring data in Pine Island Bayou, Texas, and develops a Sequence-to-Sequence (S2S) model to predict turbidity using Attention-based Gated Recurrent Units with Encoder-Decoder (AT-GRU-ED) and Long Short-Term Memory (LSTM), coupled with Variational Mode Decomposition (VMD). Compared to the model without VMD, the model demonstrates satisfactory 72-hour turbidity prediction performance, achieving MAEs of 2.60 and 3.29 NTU (reductions of 53% and 58%), RMSEs of 21.08 and 31.49 NTU (reductions of 82% and 80%), and R² values of 0.96 and 0.84 on the validation and test sets, respectively. Feature importance analysis reveals that water temperature is the dominant factor influencing seasonal turbidity patterns, while real-time hourly rainfall significantly contributes to short-term variability. Turbidity typically peaks within 48 hours after rainfall events due to lagged effects from surface runoff and upstream flow. Findings suggest suspending recreational water use and water supply pumping for three days after heavy rainfall can benefit public health and improve water treatment processes. Discharges above 100 m3/s are found to accelerate sediment dilution and transport, reducing turbidity levels more quickly after the peak. In conclusion, the proposed model demonstrates reliable 72-hour turbidity prediction, supporting decision-making for water treatment plant operations and providing early warning for public recreational water use.

Deep learning↗

Investigation of Technologies to Improve Condenser Heat Transfer and Performance in a Relevant Coal-Fired Power Plant

Improvements in thermal power-generating plant performance is correlated directly to societal benefits including lower cost of reduced fuel consumption, resulting in lower cost of electricity for the consumer and reduced carbon emissions to the atmosphere. Warm steam exhausted from low-pressure steam turbines is condensed to liquid water on the exterior of thin-walled metal condenser tubes with cooling water passing through the tube interior. The condensation of steam creates a vacuum that supports turbine rotation and the concurrent generation of electricity. This vacuum is optimized when heat transfer across the wall of condenser tube is maximized. Common hindrances to heat transfer include foulants in cooling water that may form and adhere to the interior of condenser tubes, including mineral scale, microbiological films, and particulate deposition. Flowing cooling water may also include a laminar layer at the interior metal surfaces that travels more slowly than bulk water flow, serving to impede heat transfer. On the tube exterior, condensing steam forms an insulating layer of water that flows down the tube and reduces the effectiveness of cooling. Both the interior and exterior barriers to optimal heat transfer may be alleviated to some extent by surface treatments. On the tube interior, hydrophobic coatings may be applied that can reduced the adherence of foulants and of the laminar flow layer to the tube surface. On the tube exterior, hydrophobic coatings or mechanical treatments can be applied that may result in the termination of droplet growth and the departure of droplets from the surface rather than coalescence into a continuous layer of flowing water. Fourteen surface treatments were applied to condenser tubes in this study, including eight interior coatings and six exterior treatments, five of which were coatings and one a microstructural texture. Heat transfer measurement equipment simulating conditions in the condenser of an operating power plant was used to determine heat transfer coefficients by measuring sufficient flow, temperature, water chemistry and other data. Several of the tubes with interior surface treatments showed improvement in heat transfer coefficients compared with a plain (uncoated) tube, and several of the tubes with exterior surface treatments also showed enhanced heat transfer coefficients.

01 COAL, LIGNITE, AND PEAT↗

DeepPhenoMem V1.0: deep learning modelling of canopy greenness dynamics accounting for multi-variate meteorological memory effects on vegetation phenology

Abstract. Vegetation phenology plays a key role in controlling the seasonality of ecosystem processes that modulate carbon, water and energy fluxes between the biosphere and atmosphere. Accurate modelling of vegetation phenology in the interplay of Earth's surface and the atmosphere is thus crucial to understand how the coupled system will respond to and shape climatic changes. Phenology is controlled by meteorological conditions at different timescales: on the one hand, changes in key meteorological variables (temperature, water, radiation) can have immediate effects on the vegetation development; on the other hand, phenological changes can be driven by past environmental conditions, known as memory effects. However, the processes governing meteorological memory effects on phenology are not completely understood, resulting in their limited performance of vegetation phenology represented in land surface models. A deep learning model, specifically a long short-term memory network (LSTM), has the potential to capture and model the meteorological memory effects on vegetation phenology. Here, we apply the LSTM to model the vegetation phenology using meteorological drivers and high-temporal-resolution canopy greenness observations through digital repeat photography by the PhenoCam network. We compare a multiple linear regression model, a no-memory-effect LSTM model and a full-memory-effect LSTM model to predict the whole seasonal greenness trajectory and the corresponding phenological transition dates across 50 sites and 317 site years during 2009–2018, covering deciduous broadleaf forests, evergreen needleleaf forests and grasslands. Results show that the deep learning model outperforms the multiple linear regression model, and the full-memory-effect LSTM model performs better than the no-memory-effect model for all three plant function types (median R2 of 0.878, 0.957 and 0.955 for broadleaf forests, evergreen needleleaf forests and grasslands). We also find that the full-memory-effect LSTM model is capable of predicting the seasonal dynamic variations of canopy greenness and reproducing trends in shifting phenological transition dates. We also performed a sensitivity analysis of the full-memory-effect LSTM model to assess its plausibility, revealing its coherence with established knowledge of vegetation phenology sensitivity to meteorological conditions, particularly changes in temperature. Our study highlights that (1) multi-variate meteorological memory effects play a crucial role in vegetation phenology, and (2) deep learning opens up new avenues for improving the representation of vegetation phenological processes in land surface models via a hybrid modelling approach.

Geology↗

Enhanced Warming in Global Dryland Lakes and Its Drivers

Lake surface water temperature (LSWT) is sensitive to climate change. Previous studies have found that LSWT warming is occurring on a global scale and is expected to continue in the future. Recently, new global LSWT data products have been generated using satellite remote sensing, which provides an inimitable opportunity to study the LSWT response to global warming. Based on the satellite observations, we found that the warming rate of global lakes is uneven, with apparent regional differences. Indeed, comparing the LSWT warming in different climate zones (from arid to humid), the lakes in drylands experienced more significant warming (0.28 °C decade-1) than those in semi-humid and humid regions (0.19 °C decade-1) during previous decades (1995–2016). By further quantifying the impact factors, it showed that the LSWT warming is attributed to air temperature (74.4%), evaporation (4.1%), wind (9.9%), cloudiness (4.3%), net shortwave (3.1%), and net longwave (4.0%) over the lake surface. Air temperature is the main driving force for the warming of most global lakes, so the first estimate quantification of future LSWT trends can be determined from air temperature projections. By the end of the 21st century, the summer air temperature would warm up to 1.0 °C (SSP1-2.6) and 6.3 °C (SSP5-8.5) over lakes, with a more significant warming trend over the dryland lakes. Combined with their higher warming sensitivity, the excess summer LSWT warming in drylands is expected to continue, which is of great significance because of their high relevance in these water-limited regions.

54 ENVIRONMENTAL SCIENCES↗

A GPU-based 2D shallow water quality model

In this paper, a 2D shallow water flow solver integrated with a water quality model is presented. The interaction between the main water quality constituents included is based on the Water Quality Analysis Simulation Program. Efficiency is achieved by computing with a combination of a Central Processing Unit (CPU) and a Graphics Processing Unit (GPU) device. This technique is intended to provide robust and accurate simulations with high computation speedups with respect to a single-core CPU in real events. The proposed numerical model is evaluated in cases that include the transport and reaction of water quality components over irregular bed topography and dry–wet fronts, verifying that the numerical solution in these situations conserves the required properties (C-property and positivity). The model can operate in any steady or unsteady form allowing an efficient assessment of the environmental impact of water flows. The field data from an unsteady river reach test case are used to show that the model is capable of predicting the measured temporal distribution of dissolved oxygen and water temperature, proving the robustness and computational efficiency of the model, even in the presence of noisy signals such as wind speed.

54 ENVIRONMENTAL SCIENCES↗

Improving a Multilevel Turbulence Closure Model for a Shallow Lake in Comparison With Other 1-D Models

Lakes differ from lands in water availability, heat capacity, albedo, and roughness, which affect local surface-atmospheric interactions. This study modified a multilevel upper ocean model (UOM) for lake applications and evaluated its performance in Lake Taihu (China) with comprehensive measurements against three popular one-dimensional (1-D) lake models. These models were based on different concepts, including the self-similarity (FLake), the wind-driven eddy diffusion (LISSS), the k-ε turbulence closure (SIMSTRAT), and a simplified turbulence closure (UOM). The surface flux scheme in these models was unified to exclude the discrepancies in representing air-lake exchanges. All models in their default formulations presented obvious cold water temperature biases and largely underestimated the lake surface temperature (LST) diurnal range. For each model, these deficiencies were significantly reduced by incorporating new physics schemes or calibrated tunable parameters based on systematic sensitivity tests. The primary modifications for UOM included (1) a new scheme of decreased surface roughness lengths to better characterize the shallow lake, (2) a solar radiation penetration scheme with increased light extinction coefficient and surface absorption fraction to account for the high water turbidity, and (3) turbulent Prandtl number increased by a factor of 20 to reduce the turbulent vertical mixing. All other models were improved in these three aspects (roughness, extinction, and mixing) within their original formulations. Given these improvements, UOM showed superior performance to other models in capturing LST diurnal cycle and daily to seasonal variations, as well as summer-autumn vertical stratification changes. The new UOM is well suited for application in shallow lakes.

54 ENVIRONMENTAL SCIENCES↗

Data for Myers-Pigg et al. (2026), "Short-term coastal forest responses to a hurricane-scale freshwater and saltwater flooding experiment"

Coastal upland forests are exposed to intensifying precipitation regimes and sea level rise, increasing tree mortality and transforming these coastal forests into wetland ecosystems. Despite these well-known risks, the differing degrees to which hydrological, biogeochemical, and biological components of upland forests respond to novel salinity exposure is relatively unknown. The Terrestrial Ecosystem Manipulation to Probe the Effects of Storm Treatments (TEMPEST) experiment decouples two distinct disturbances associated with hydrological extremes: (1) flooding from heavy precipitation and (2) exposure to saline conditions from storm surge. This dataset includes data reported in Myers-Pigg et al. (2025), which analyzed data from the first TEMPEST flooding treatment in 2022. This includes: - Colored dissolved organic matter in porewaters - Soil temperature and oxygen - Groundwater temperature and chemistry - Dissolved organic carbon concentrations in porewaters - Soil-to-atmosphere CH4 and CO2 fluxes - Soil temperature, water content, and electrical conductivity - Root-influenced CH4 and CO2 flux - Tree sap flow velocity - The R analytical code and documentation about the computational environmental in which it was run (the "sessionInfo.txt" file) All data files are plain-text comma separated value (CSV) and no special software is required to read them.

54 ENVIRONMENTAL SCIENCES↗

Climate Change Science Review 2018 and Associated Social and Economic Impacts

Climate change and its impacts on average temperature, water supply, agriculture, coastal flooding, biodiversity, social and economic stability, human migration, and overall global stability is one of the leading threats emerging for humanity, and is likely to increase as a threat for decades to come. This report represents a snapshot of climate change data, information, and understanding, as of 2018, and can serve as a kind of benchmark for changes going forward in time. This report covers temperature change and heat effects, atmospheric and ocean circulation, freshwater supply changes, sea level rise and flooding, extreme climate events, oceanic deoxygenation, land degredation, social and economic changes, migration, and food. Data and information on all these issues represent a compelling body of knowledge supporting the scientific hypothesis describing climate change, and an important mile marker in our effort to track the unfolding nature of the problem. A slide presentation that summarizes the content of this report is in Appendix A and can serve as an executive summary for the report.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Assessing the Influence of Organic Carbon, Aging Time and Temperature on Bioaccessibility of Bifenthrin

Tenax extraction, a measure of chemical desorption rates from sediments, was used to evaluate the bioaccessibility of bifenthrin in two different sediments exposed to three temperatures aged over a 56-d holding period. A 24-h single-point Tenax extraction was used and parent 14 C-bifenthrin and polar metabolites were quantified in the sediment and Tenax. Bioaccessibility of bifenthrin was inversely related to the organic carbon (OC) content in the sediment, holding time, and temperature. Furthermore, sequestration of the bifenthrin into slowly desorbing fractions within the sediment appears to have decreased degradation of the parent compound into metabolites and decreased the amount of parent compound bioaccessible for uptake by the Tenax. These results suggest that the environmental risk of bifenthrin to aquatic species is greatest immediately after the pesticide enters a waterbody after runoff, for low-OC content sediments, and in areas or seasons where water temperatures are colder.

54 ENVIRONMENTAL SCIENCES↗

A Novel High Energy Density Sorption-based Thermal Battery for Low-grade Thermal Energy Storage

Thermal energy storage (TES) can alleviate peak demand on the electricity grid by offsetting building thermal loads, increasing the grid’s reliability and resilience. However, low energy density and poor energy performance of existing TES technologies limit their applications. Sorption-based thermal battery (STB) system is thus developed using three-phase sorption technology to harvest low-temperature heat, store it with a much higher energy density than common TES systems and dehumidify air or provide space cooling in buildings. Although STB has been experimentally proved to be feasible, influencing factors on its performance are still unknown by far. Therefore, this paper conducted a parametric analysis on crystallization and crystal dissolution performance of a developed STB test rig. The crystallization results showed that the energy density of the STB increased with reducing the solution flow rate and the cooling water temperature. The dissolution results showed that a higher discharge rate of the STB can be achieved with increasing the flow rate and temperature of inlet diluted solution. The work in this study is helpful to the optimal design and operation of the STB system.

Wang, Lingshi↗

Subsurface redox potential and water level at the Elkhorn Slough NERR

This resource contains various hydrological, and geochemical data from Elkhorn Slough National Estuarine Research Reserve from the years 2020 and 2021. These data have been used to assess how continuous measurements of environmental variables. The data can be used to understand processes at timescales over which biochemical transformations can happen. Especially, the data were used to explain the local subsurface hydrology, and its implication, in an experimental transect in a coasta estuary. Water level and water temperature were measured in-situ with Solinst pressure transducer loggers (Ontario, Canada). Redox potential was collected using in-situ, redox sensors (Paleoterra, The Netherlands) connected to CR1000X Campbell data loggers (Logan, Utah). Meteorological data was gathered from the Elkhorn Slough meteorological station.

54 ENVIRONMENTAL SCIENCES↗

Silicon Dioxide Deposited Using Atmospheric Pressure Plasma Chemical Vapor Deposition for Improved Adhesion and Water Intrusion Resistance for Lightweight Manufacturing

This work aims to demonstrate the barrier coating, and adhesion promoting properties of silica-based coatings deposited using an atmospheric pressure plasma torch (APPT). This is achieved by applying an industrial grade adhesive to silica thin films deposited, on the surfaces to be joined, using atmospheric pressure plasma chemical vapor deposition (APP-CVD), to make single joint lap shear samples of different metal combinations commonly found in lightweight manufacturing such as aluminum and magnesium as well as steel. To deposit these thin films, two separate silicon based organic precursors, hexamethyldisiloxane (HMDSO), and tetraehylorthosilicate (TEOS), are used. Here, samples are bonded using DuPont Betamate 1486 adhesive, and the lap shear results for these films are compared to the lap shear results of a chemically cleaned control using the same adhesive. The APPT uses a microwave power supply and gas mixtures of N 2 and Ar. The adhesion of the films are tested using lap shear, and elevated temperature water soaks are conducted on the joints as well to simulate environmental exposure. Lap shear results from samples with silica thin films max shear stress are 25%-115% increase compared to control samples depending on material. After exposure to water soak the max shear strength of the joints decreased by less than 15%, which demonstrates the films capabilities as a water barrier. Film morphology is examined using Scanning Electron Microscopy (SEM), and the film’s composition and approximate thickness are obtained using Rutherford Backscattering Spectroscopy (RBS).

36 MATERIALS SCIENCE↗

Experimental evaluation of direct current magnetron sputtered and high-power impulse magnetron sputtered Cr coatings on SiC for light water reactor applications

Two types of physical vapor deposition Cr coatings were deposited on chemical vapor deposited SiC coupons using conventional direct current magnetron sputtering (DCMS) and high-power impulse magnetron sputtering (HiPIMS) to mitigate the corrosion of SiC, an advanced fuel and structural material in light water nuclear reactor cores. Coating microstructure was characterized using scanning electron microscopy and scanning transmission election microscopy. X-ray diffraction analysis was conducted for phase identification and qualitative analysis of residual stresses. The mechanical integrity of the coatings was evaluated using scratch testing, micro-indentation, and nano-indentation tests. Additionally, the microstructure of the DCMS coating consisted of fine columnar grains with nanoscale intercolumnar channels, while the HiPIMS microstructure was denser and free of any columnar defects. The DCMS coating showed a small tensile residual stress, while the HiPIMS coating was under compressive stress. Both types of coatings showed good mechanical integrity in terms of ductility and adhesion to the substrate. Corrosion performance of the coatings was assessed with a 30-day high temperature water autoclave test. Both types of coatings formed a protective Cr 2 O 3 surface layer 20-30 nm thick during the autoclave test. In the DCMS coating, the columnar defects provided permeation pathways for water penetration resulting in oxide formation in the intercolumnar regions in the interior of the coating. Overall, both types of Cr coatings offer promise for the mitigation of hydrothermal corrosion of SiC in light water reactor operating environments.

36 MATERIALS SCIENCE↗

We Just Want to Pump…You Up! Forecasting Grid-Connected Heat Pump Water Heater Energy Savings and Load Shifting Potential for the Southeast U.S.

Heat pump water heaters (HPWH) can achieve energy savings of 60-70% compared to conventional electric-resistance water heaters. However, even with a favorable simple payback period within the typical product lifetime, HPWHs make up only 1% of all electric water heaters sold in the residential sector. Market adoption is challenged, in part, by the lack of effective energy efficiency programs in the U.S. region with the greatest amount of residential electric water heaters. The recent integration of connected functionality into HPWHs offers the capability to shift load without undue negative impact on customers. This capability can provide value to utilities with peak load constraints, motivating them to promote HPWHs for the first time. This paper will present a methodology to forecast connected HPWH energy use and extrapolate load shifting potential for the Southeast U.S. region. The methodology leverages data from a robust connected HPWH field study conducted in the Pacific Northwest. A coefficient of performance (COP) relationship for HPWHs was developed using ambient and inlet water temperature data to forecast HPWH performance on a month-by-month basis. Using the forecasted COP, HPWH operating hours were calculated for meeting load, which serve as the proxy to extrapolate load shifting potential from the Pacific Northwest to the Southeast. As a use case, analytical results are presented for a specific utility. This methodology, in combination with market analysis, facilitates the development of customized energy savings and load shifting forecasts to understand the potential impacts of launching connected HPWH programs in specific utility service territories.

heat pump water heater, energy savings, load shift↗

Distributed fiber sensing systems for 3D combustion temperature field monitoring in coal-fired boilers using optically generated acoustic waves (Final Report)

In this project, we have developed and tested three kinds of fiber optic sensing systems for real time monitoring of temperature variations within an industrial scale boiler furnace. The fiber optic sensing systems target spatial and temporal distributions of high temperature profiles in a boiler furnace in fossil power plants. The reconstructed temperature profile will provide critical input for the control mechanisms to optimize the combustion process. This temperature profile will address the essential problem for fossil power plants in achieving higher efficiency and fewer pollutant emissions. Acoustic pyrometer systems have been used to reconstruct temperature field of power plant boilers based on measuring TOF (times-of-flight) of sound waves along some straight paths in a 2D cross-section of the boiler. In this project, optically generated acoustic signals from a fiber optic sensing system have replaced the acoustic signals generated from an electrical transducer. A 3D reconstruction algorithm replaced the previous 2D model. In this project, three kinds of fiber optic sensing systems have been developed and tested. They are fiber optic sensing system I, fiber optic sensing system II (Distributed Sensing System I) and fiber optic sensing system III (Distributed Sensing System II). For fiber optic sensing system I, the fiber optic ultrasound generator acts as a signal generator. A microphone, hydrophone or other electronic devices serve as a signal receiver. In this system, there are one generator and one receiver. Distance test, water temperature test, air temperature test, air temperature reconstruction, and GE ISBF pilot test were performed by Fiber optic sensing system I. The fiber optic sensing system I successfully detected temperature in all these tests. We got 2D temperature reconstruction results by using the fiber optic sensing system I and it matched the reference data. The fiber optic sensing system I successfully survived in GE ISBF boiler environment (480 °F). For fiber optic sensing system II (Distributed Sensing System I), it is an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Fiber Bragg Grating (FBG) and Fabry-Perot (FP) sensor act as a signal receiver. In this system, there is one generator and one receiver. Aluminum plate temperature test, furnace high temperature test, and GE ISBF pilot test were performed by the fiber optic sensing system II. Fiber optic sensing system II successfully detected the temperature in all these tests. The fiber optic sensing system II successfully survived at up to 700 °C furnace environment and 320 °C GE ISBF boiler environment. For fiber optic sensing system III (Distributed Sensing System II), it is also an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Multiple FP fiber sensors act as signal receivers. In this system, there is one generator and three receivers. Three GE ISBF pilot tests were performed by fiber optic sensing system III. The fiber optic sensing system III survived in the cold flow tests in GE’s ISBF pilot test facility. However, we didn’t get high temperature data by using this system since the nanosecond laser issues. During the period of the project, test trials, data simulation and algorithm optimization was performed successfully. For real time temperature field construction, the sampling rate must be fast enough to capture the field variations. The technology of Code-division multiple access (CDMA) is well studied which could allow parallel multiplexing, even if signals overlap in time or frequencies. Moreover, it has been known that extending the length of signal significantly improves SNR. For acoustic signals, these multiplexing techniques have also been widely used, mainly for sonar and acoustic communications. The CDMA modulation technique has been proposed and studied to guarantee high network throughput, low channel access delay and low energy consumption. We have studied the temperature field reconstruction using Gaussian Radial Basis Functions (GRBF)-based approximation approach. Reconstruction of 3D temperature field using Neural Networks with measured TOF and known propagation paths is feasible. 2D and 3D temperature field reconstruction simulation results are achieved. The milestone status is shown in Table 1. We finished milestone 1-8 and milestone 10. For milestone 9, we did three pilot tests by using the fiber optic sensing system III (Distributed Sensing System II) at GE Power. However, due to the failure of the ns laser, we did not get the temperature results. We conducted some additional tasks that were not originally proposed: 1) We fabricated a fiber optic sensing system I and did a pilot test based on this system. 2) In the proposal, we proposed two pilot tests at GE Power. In reality, we finished at least seven pilot tests at GE Power. GE Power has made a lot of efforts for supporting the pilot tests. 3) We got a simulation results based on CDMA. In summary, most of the tasks have been accomplished. The outcome of this project removed a few barriers that hinder the achievement of the final product of the distributed sensing systems. With the successful accomplishment of this project, a prototype of the fiber optic sensing system can be fabricated to attract more interests from companies and other funding agencies.

47 OTHER INSTRUMENTATION↗