Search NASA⌕ Search

SEARCH · Search NASA

Results for “x-ray fluorescence (XRF)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Monitor for measuring mercury emissions

A mercury emissions monitor includes a mercury sensor tape configured to be fed in a reel-to-reel manner between first and second tape reels, wherein the mercury sensor tape includes a thin metallic film configured to form an amalgam with detected mercury. A mercury collection unit is configured to receive into a chamber a sample of a gas containing mercury, wherein the mercury collection unit is further configured to permit passage of portions of the mercury sensor tape through the chamber containing the gas sample so that the amalgam is formed with the thin metallic film. A mercury analysis unit includes a total reflection x-ray fluorescence (“TXRF”) system configured to perform a TXRF analysis of the amalgam, wherein the mercury analysis unit is configured to permit passage of the mercury sensor tape within a proximity of an XRF detector of the TXRF system. The mercury collection unit and the mercury analysis unit are positioned between the first and second tape reels so that the mercury sensor tape can move in a continuous manner from the first tape reel through the chamber of the mercury collection unit, then within sufficient proximity to the XRF detector, to be then taken up onto the second tape reel.

Kumar, Nalin↗

Nanoscale elemental and morphological imaging of nitrogen-fixing cyanobacteria

Nitrogen-fixing cyanobacteria bind atmospheric nitrogen and carbon dioxide using sunlight. This experimental study focused on a laboratory-based model system, Anabaena sp., in nitrogen-depleted culture. When combined nitrogen is scarce, the filamentous prokaryotes reconcile photosynthesis and nitrogen fixation by cellular differentiation into heterocysts. To better understand the influence of micronutrients on cellular function, 2D and 3D synchrotron X-ray fluorescence mappings were acquired from whole biological cells in their frozen-hydrated state at the Bionanoprobe, Advanced Photon Source. To study elemental homeostasis within these chain-like organisms, biologically relevant elements were mapped using X-ray fluorescence spectroscopy and energy-dispersive X-ray microanalysis. Higher levels of cytosolic K + , Ca 2+ , and Fe 2+ were measured in the heterocyst than in adjacent vegetative cells, supporting the notion of elevated micronutrient demand. P-rich clusters, identified as polyphosphate bodies involved in nutrient storage, metal detoxification, and osmotic regulation, were consistently co-localized with K + and occasionally sequestered Mg 2+ , Ca 2+ , Fe 2+ , and Mn 2+ ions. Machine-learning-based k-mean clustering revealed that P/K clusters were associated with either Fe or Ca, with Fe and Ca clusters also occurring individually. In accordance with XRF nanotomography, distinct P/K-containing clusters close to the cellular envelope were surrounded by larger Ca-rich clusters. The transition metal Fe, which is a part of nitrogenase enzyme, was detected as irregularly shaped clusters. The elemental composition and cellular morphology of diazotrophic Anabaena sp. was visualized by multimodal imaging using atomic force microscopy, scanning electron microscopy, and fluorescence microscopy. This paper discusses the first experimental results obtained with a combined in-line optical and X-ray fluorescence microscope at the Bionanoprobe.

Anabaena sp↗

MapX An In Situ, Full-frame X-Ray Spectroscopic Imager for Planetary Science and Astrobiology

Microbial life exploits micron-scale disequilibria at boundaries where valence, chemical potential, pH, Eh, etc. vary on a length scale commensurate with the organisms - 10's to 100's of microns. The detection of accumulations of the biogenic elements C,N,O,P,S at appropriate concentrations on or in a mineral/ice substrate would constitute permissive evidence of extant life, but context is also required. Does the putative biosignature exist under habitable conditions? Under what conditions of P, T, and chemical potential was the host mineralogy formed? MapX is an in situ robotic spacecraft instrument that images the biogenic elements C, N, O, P, S, as well as the cations of the rock-forming minerals (Na, Mg, Al, Si, K, Ca, Ti, Cr, Mn, Fe) and important anions such as Cl, Fl. MapX provides element maps with less than or equal to100 microns resolution over a 2.5 cm X 2.5 cm area, as well as quantitative XRF spectra from ground- or instrument-selected Regions of Interest (ROI). XRF spectra are converted to mineralogies using ground- or instrument-based algorithms. Either X-ray tube or radioisotope sources such as 244Cm (Alpha-particle and gamma- ray fluorescence) can be used. Fluoresced sample Xrays are imaged onto an X-ray sensitive CCD through an X-ray MicroPore Optic (MPO). The MapX design as well as baseline performance requirements for a MapX instrument intended for life detection / identification of habitable environments will be presented.

Astrobiology↗

XRF Characterization of MMOD Impact Damage

Introduction The Hypervelocity Impact Technology (HVIT) Group at the NASA Johnson Space Center (JSC) has performed over 150 post flight MMOD inspections on returned space-ex-posed hardware and collected over 1,600 samples. Determination of the impactor source typically requires an analysis of the projectile residue in the damage feature. At this time, about 20% of the samples have been processed. Types of Samples Samples in the HVIT group collection can be classified into two types. Indirect (non-destructive) samples are produced when a pliable material (e.g., adhesive tape or dental mold) is inserted into an impact feature. With this type of sampling technique, crater material and (hopefully) projectile residue material is embedded in the sample media and can detected using further chemical characterizing techniques. Direct (destructive) sampling involves the in-tact extraction of material from the spacecraft and is done in a manner that the entire impact feature can be excised intact. This technique provides the greatest chance of successfully determining impactor source due to the entirety of the projectile remnants being present within the collected sample. Updated Projectile Residue Detection Techniques Previous assessments of projectile provenance have involved the use of samples that are first mounted in epoxy, sectioned to expose the crater interior, imaged with a scanning electron microscope (SEM), then any observed impactor residue was then analyzed using an energy dispersive spectrometer (EDS). This technique, while proven, may be supplemented with other types of elemental analysis techniques that can observe major element chemistry, in order to improve throughput of sample analysis. The Astromaterials Research and Exploration Science (ARES) Division at JSC, for example, operates a Bruker M4 Tornado micro-X-Ray fluorescence (XRF) spectrometer, capable of creating elemental maps of areas around these small impact features in a couple of hours, with a spot size <20 μm. The potential advantage with this technique lies in sample preparation, as no polishing or conductive coatings are needed. Early trials attempted to deter-mine impactor composition by collecting spectra from intact samples by aiming the X-Rays directly into the impact feature, but the signal:noise ratio was too low for confident material identification. Sample preparation for XRF then relies on sectioning the samples parallel to the impactor trajectory in order to expose the largest area of subsurface damage possible, thus maximizing the signal from any small impactor remnants. Complementary to the use of XRF for sample analysis, ARES also houses a Nikon XTH 320 micro-X-Ray computed tomography (XCT). This instrument can be used to create 3D visualizations of impact damage for the determination of crater volumes and dimensions, as well as for the determination of the best place to section each sample for the subsequent XRF analysis.

J L Hyde↗

Elemental composition of the Martian surface

The Viking landers carried X-ray fluorescence spectrometers (XRFS) to the surface of Mars for direct in-situ measurements of the elemental composition of samples that could be acquired by the surface sampler scoops. A total of 21 samples at two landing sites were acquired and analyzed. In this review, the constraints imposed on the design and operation of the XRFS; the accuracy and precision limitations of XRF; and the interpretation of the results are discussed. The latter includes relevance of the investigation to Martian geological processes, SNC meteorites, the formation and history of Mars, and future mission objectives/capabilities.

Clark, Benton C.↗

Benchmarking of X‐Ray Fluorescence Microscopy with Ion Beam Implanted Samples Showing Detection Sensitivity of Hundreds of Atoms

Abstract Single impurities in insulators are now often used for quantum sensors and single photon sources, while nanoscale semiconductor doping features are being constructed for electrical contacts in quantum technology devices, implying that new methods for sensitive, non‐destructive imaging of single‐ or few‐atom structures are needed. X‐ray fluorescence (XRF) can provide nanoscale imaging with chemical specificity, and features comprising as few as 100 000 atoms have been detected without any need for specialized or destructive sample preparation. Presently, the ultimate limits of sensitivity of XRF are unknown – here, gallium dopants in silicon are investigated using a high brilliance, synchrotron source collimated to a small spot. It is demonstrated that with a single‐pixel integration time of 1 s, the sensitivity is sufficient to identify a single isolated feature of only 3000 Ga impurities (a mass of just 350 zg). With increased integration (25 s), 650 impurities can be detected. The results are quantified using a calibration sample consisting of precisely controlled numbers of implanted atoms in nanometer‐sized structures. The results show that such features can now be mapped quantitatively when calibration samples are used, and suggest that, in the near future, planned upgrades to XRF facilities might achieve single‐atom sensitivity.

36 MATERIALS SCIENCE↗

CHEMIN: A Mineralogical Dust Analyzer for the Odyssey Mission to Comet Kopff

The Odyssey spacecraft will be launched in June 2006 and will rendezvous with periodic Comet Kopff in September 2009. Odyssey will initially perform slow flybys of the active Kopff nucleus at distances between 500 and 100 km, and will then be placed in orbit around the nucleus at altitudes between 200 and 50 km. Odyssey's scientific payload of seven instruments includes CHEMIN, a mineralogical dust analyzer, which will make the first direct measurements of the crystal structure and elemental composition of cometary dust. CHEMIN will simultaneously perform X-ray Diffraction and X-ray Fluorescence (XRD/XRF) of individual 1-100 micron dust particles collected passively as the spacecraft is immersed in the comet's coma. The instrument has the geometry of a microfocus X-ray camera, with a postage stamp-sized energy-discriminating CCD in place of the film, and a miniature Cu target X-ray tube as the X-ray source. The CHEMIN flight instrument will weigh less than 2 kg., will have a total volume of about 1 liter, and will operate on 3 watts of power. Individual analyses will require 1-2 hours. XRD maxima from 5 to 65 degrees two-theta will be collected, encompassing definitive peaks for all known minerals. XRF data will be simultaneously collected for elements C through U. The instrument has sufficient resolution to allow Rietveld refinement of the diffraction data. Rock types as complex as basalt have been quantitatively analyzed using a CHEMIN laboratory prototype. Selected examples of diffraction experiments performed on more than 30 minerals and rock types by the CHEMIN laboratory prototype will be discussed.

Blake, David↗

Probing the Mechanism of Selective Phosphate Adsorption from Wastewater Using Aqueous and Synchrotron X-ray Characterization

Ion exchange shows promise for recovering phosphate from wastewater as value-added products, but requires high phosphate selectivity to compete with conventional treatment. Hybrid anion exchange (HAIX) resins, which contain non-selective basic functional groups and selective iron oxide nanoparticles (FeOnp), can effectively remove phosphate from wastewater. However, knowledge gaps remain regarding the mechanisms of phosphate selectivity and influence of competing ions, hindering needed efforts to model adsorption dynamics and design scalable adsorption processes for varying wastewaters. To address these gaps, we integrated aqueous-phase adsorption analysis with solid-phase, synchrotron-based X-ray characterization; this integration facilitated elucidation of the distribution and speciation of iron, phosphate, and competing anions on HAIX resins. We compared a quaternary ammonium-functionalized HAIX resin (SBA) to a tertiary amine version (WBA) to determine the role of functional groups. X-ray radiography revealed differences in FeOnp speciation (goethite vs. ferrihydrite) and distribution (peripheral vs. homogeneous) between the resins, resulting in varied phosphate affinity and intraparticle diffusion resistance. Using micro-X-ray fluorescence (μ-XRF) and micro-X-ray absorption near-edge structure (μ-XANES) spectroscopy, we identified differences in where and how phosphate binds across resin types and wastewaters. Across wastewater compositions, FeOnp sites in WBA contribute more to phosphate adsorption than in SBA, possibly due to variations in Fe distribution and speciation. Phosphate adsorption densities calculated from quantitative μ-XRF maps matched those from aqueous analysis, demonstrating the effectiveness of this integrated approach. Altogether, results demonstrate the use of synchrotron-based X-ray characterization for investigating adsorption mechanisms and advance HAIX as a phosphate recovery technology from complex wastewaters.

Nutrient recovery↗

Sulphur variations in annually layered stalagmites using benchtop micro-XRF

Variation of sulphur in annually laminated stalagmites can be used to infer the impact of past volcanic activities, anthropogenic pollution, and climate change due to increased bushfire activity. The synchrotron radiation micro-X-Ray fluorescence (SR-XRF) microprobe is a powerful tool to analyse and image sulphur recorded in stalagmites with micrometre resolution. However, access to SR-XRF beamlines can be limited, so researchers must select the most promising stalagmites for imaging. Benchtop micro-XRF is an effective tool for trace elemental analysis of speleothem samples and is a candidate for routine laboratory measurement of sulphur along stalagmite laminae and screening for SR-XRF. Here, this study describes a protocol using matrix-matched standards to measure annual variations of sulphur at trace to percent level along the laminae of two Western Australian stalagmites, one of which already having been analysed using SR-XRF. Parameters that affected quantitation include X-ray tube voltage and current, spot size of the X-ray beam and stalagmite surface roughness and porosity. The use of a 20 μm X-ray spot size provides sub-annual spatial resolution that can be completed in an overnight scan. The features in a 1000 point micro-XRF analysis of sulphur along a 20 mm transect show good consistency with SR-XRF microprobe data. Micro-XRF mapping was also performed to produce chemical images on the stalagmite and compared with Raman and X-ray diffraction (XRD) to confirm that the stalagmite is exclusively calcite, with no aragonite, and that the source of sulphur in the samples was gypsum and anhydrite. Regions of very high sulphur in the micro-XRF maps were found to be artefacts due to diffraction of the incident beam but these could be efficiently removed by using a multiple point statistics approach to produce a clean image suitable for analysis of the laminae. This work shows the potential of micro-XRF for routine analysis of sulphur in stalagmites, and to streamline sample characterisation before SR-XRF imaging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Initial analysis of “stone” size Ryugu samples: current status

As a part of the initial analysis of the Ryugu samples, we perform a variety of analyses of millimeter-sized "stones". Our goals are to elucidate the entire formation process of C-type asteroid Ryugu from the viewpoint of petrology and mineralogy ande obtain necessary information by sample analysis, and then simulate the formation of Ryugu based on the evidencef obtained rom sample analysis. Eighteen stones (8 from Room A and 10 from Room C) were received from the ISAS curation facility on June 1, 2021, and brought into a fully nitrogen-displaced glove box at Tohoku University. At the same time, we also received the powder samples from Room A and Room C. To completely block the atmosphere from leaking into the container, all samples were put in the sample transport containers prepared by ISAS, transferred from the main chamber to the glovebox at ISAS, and then all containers were completely sealed in plastic bags with moisture and oxygen absorbers. No moisture or oxygen was detected when the bags were opened in the glove box at Tohoku University, so it was confirmed that there was no exposure to the atmosphere during transport. To date, a number of analyses have been carried out successfully and almost on schedule. The analysis started with the measurement of reflectance spectra, which are sensitive to atmospheric oxidation, hydroxylation, and adsorbed water. The visible, near-infrared, and mid-infrared reflectance spectra were measured while the samples were kept airtight. The spectra of powder samples and stone samples (as aggregates and as single stone) were successfully obtained. A major feature of the stone team's analysis is the use of synchrotron radiation facilities around the world. Since this analysis is non-destructive, stone samples whose reflectance spectra were measured were sent to KEK, SPring-8, ESRF (France), SOLEIL (France), DESY (Germany), and APS (USA). Using these synchrotron radiation facilities, high spatial resolution and sensitivity XRD, STXM, XANES, CT [1], IR-CT, FT-IR [2, 3], XRF, and Mössbauer analyses were performed. Most of the analyses were carried out under air-tight conditions on the stone samples and the particulates separated from the stone samples. These analyses allowed us to determine the three-dimensional distribution of minerals and elements, redox state, density and porosity of the stone samples. Furthermore, as a characteristic analysis of the stone team, light elemental analysis using negative Muon was performed at the MLF facility of J-PARC with an exceptionally long allocation of machine time. This is the only non-destructive method to measure the concentration of light elements in the whole (not the surface) of stone samples. Because the characteristic X-rays produced by muon irradiation are much higher in energy than the fluorescent X-rays produced by X-ray irradiation, there is little effect of self-absorption by the sample, and therefore, the concentration of light elements such as carbon, oxygen, and Na in the entire "stone" sample can be determined. Some stone samples are currently being measured for heat and strength physical properties in order to understand the physical properties of asteroid Ryugu. The data obtained from these measurements are useful for interpreting the remote-sensing data data taken from the surface layer of the asteroid Ryugu [4-7]. It is also important for understanding the behavior of the Ryugu material during impact events. The surfaces of many stone samples were observed by electron microscopy and other techniques, especially on natural “flat” surfaces formed on 5 stomes. As a result, characteristric mineral aggregates formed by the reactions with water and characteiristic impact features were observed on some of the samples. Based on the observations of surfaces and the synchrotron measurements of the whole stones, important objects such as characteristic structures and specific crystal aggregates for understanding the formation history of the asteroid were identified, and these parts were separated from the stone samples using an Xe beam (pFIB) and analyzed by various methods including transmission electron microscopy and synchrotron radiation analysis. Many stone samples, from which important objects have been separated, are embedded in epoxy resin and cut to produce many polished sections. Electron microscopy and spectroscopic measurements of the polished surfaces are being carried out to reveal the detailed mineralogical properties and elemental distribution inside the stone samples. In the fall, machine time for synchrotron radiation will begin, and we plan to analyze single crystals and characteristic objects separated from the stone samples.

Tomoki Nakamura↗

Combined Backscatter Moessbauer Spectrometer and X Ray Fluorescence analyzer (BaMS/XRF) for planetary surface materials

A backscatter Moessbauer spectrometer (BaMS) with included x ray fluorescence (XRF) capability for the Mars Environment Survey (MESUR) Mission, which has been proposed by NASA for 1998, is being developed. The instrument will also be suitable for other planetary missions such as those to the Moon, asteroids, and other solid solar-system objects. The BaMS would be unique for MESUR in providing information about iron mineralogy in rocks, clays, and other surface materials, including relative proportions of iron-bearing minerals. It requires no sample preparation and can identify all the normal oxidation states of iron (3+, 2+, 0). Thus, BaMS is diagnostic for weathering and other soil-forming processes. Backscatter design allows the addition of XRF elemental analysis with little or no modification. The BaMS/XRF instrument complements the thermal analyzer with evolved gas analyzer (TA-EGA) and the alpha-proton x-ray spectrometer (APXS) proposed (along with BaMS) for geochemical analysis on MESUR.

Agresti, D. G.↗

Characterization and Geological Implications of Precambrian Calcite-Hosted Phosphate

Constraints on marine phosphate availability and cycling directly inform our understanding of long-term biological evolution. However, early Earth phosphate records are sparse, biased toward siliciclastic samples, and susceptible to post-depositional modification. Well-preserved shallow marine inorganic carbonate precipitates provide a complementary yet understudied record of phosphate cycling. We combined micro-X ray fluorescence mapping, X-ray absorption, and Nuclear Magnetic Resonance spectroscopy on samples of Precambrian syndepositional herringbone calcite (HBC) and microspar to characterize phosphorus speciation and distribution in these carbonate fabrics. Phosphorus spectroscopy from synthetic calcite, HBC, and microspar, is qualitatively consistent with a disordered distribution of phosphate. These characteristics are diagnostic of calcite-hosted phosphate, which is pervasive at low concentrations in HBC and microspar. This study provides evidence that ancient, well-preserved carbonate fabrics retain phosphate sourced from seawater and highlights the potential for an unaltered archive of marine phosphate concentration over geologic time.

58 GEOSCIENCES↗

Root size and soil physicochemical properties drive microscale spatial patterns of Fe and As retention in the rice rhizosphere

Background and Aims: Radial oxygen loss from rice roots in flooded soils oxidizes and precipitates dissolved Fe(II), Mn(II), and As(III) into mixed Fe(III), Mn(III/IV), and As(V) as root plaque and in the rhizosphere soil. It is unknown how different soils and root sizes impact the spatial extent of Fe and As retention outside the root. Methods: We imaged cross-sections of 90 roots from 6 different soils using synchrotron μXRF imaging followed by k-means clustering and elliptical averaging to distinguish bulk soil, rhizosphere, plaque, and roots based on As and Fe patterns. Results: We found preferential As retention in the plaque and rhizospheres of most roots except small (< 0.45 mm) roots in silty soils with low P or high As. In contrast, clayey soils had similar As-Fe correlations across plaque, rhizosphere, and bulk soil. Large (> 0.45 mm) roots often had no oxidized rhizosphere region. We obtained an extensive dataset of 256 As and 155 Mn synchrotron μXANES measurements, which revealed that rhizosphere and plaque As was mainly inorganic As(V) and As(III), and Mn oxidation state varied between soils but not between belowground locations. Conclusion: Small roots in coarse-textured soils were less likely to have As retention in the plaque or rhizosphere compared to large roots and fine-textured soils. Furthermore, the unique and extensive data in this study provides new insight into soil and root size impacts on As retention in the rhizosphere. It is essential to investigate a representative number of samples to draw conclusions from XRF imaging.

36 MATERIALS SCIENCE↗

Chemistry in Retrieved Ryugu Asteroid Samples Revealed by Non-Invasive X-ray Microanalyses: Pink-Beam Fluorescence CT and Tender-Energy Absorption Spectroscopy

The Hayabusa2 space mission recently retrieved 5.4 g of material from asteroid Ryugu, providing the first direct access to pristine material from a carbonaceous asteroid. This study employs a novel combination of non-invasive synchrotron X-ray techniques to examine microscale chemistry (elemental distributions and element-specific chemical speciation and local structure) inside Ryugu grains without physically cutting the samples. Manganese primarily occurs in carbonate: Mn-bearing dolomite with minor earlier ankerite. Iron sulfides present as large single grains and as smaller particles in the finer-grained matrix are both predominantly pyrrhotite. At the 5 μm scale, Fe sulfides do not show the mineralogical heterogeneity seen in many carbonaceous meteorites but exhibit some heterogeneous localized oxidation. Iron is present often as intergrowths of oxide and sulfide, indicating incomplete replacement. Trace selenium substitutes for S in pyrrhotite. Copper is present as Fe-poor Cu sulfide. These results demonstrate multiple episodes of fluid alteration on the parent body, including partial oxidation, and help constrain the sequence or evolution of fluids and processes that resulted in the current grain-scale mineralogical composition of Ryugu materials.

36 MATERIALS SCIENCE↗

Micro- to nano-scale areal heterogeneity in pore structure and mineral compositions of a sub-decimeter-sized Eagle Ford Shale

Mineral and organic matter compositions & pore structures of fine-grained shale influence reservoir properties. To improve the understanding of spatial heterogeneity in core-sized samples, methods of microscale X-ray fluorescence (μXRF) mapping, (ultra-) small-angle x-ray scattering [(U)SAXS] and wide-angle X-ray scattering (WAXS) have been used to determine elemental, pore-structure variations at scales up to ~10 cm on two samples prepared at circular and rectangular orientations from a piece of Eagle Ford Shale outcrop in South Texas, USA. In addition, thin section petrography and field emission-scanning electron microscopy observations, X-ray diffraction (XRD), total organic carbon, and pyrolysis were utilized to investigate the potential spatial heterogeneity of pore types, mineral and organic matter compositions for cm-sized samples at both orientations. Overall, the siliceous-carbonate mineral contents in these two samples (8 cm×8 cm×0.08 cm and 5 cm × 8 cm × 0.08 cm, in terms of width×length×thickness) of carbonate-rich Eagle Ford Shale vary between laminations at mm scales. For the circular sample, porosity and specific surface area (SSA) variations range from 0.82 to 3.04% and 1.51 to 14.1 m 2 /g, respectively. For the rectangular sample, values for porosity and SSA vary from 0.93 to 2.50% and 3.95 to 10.8 m 2 /g. By analyzing six selected sub-samples on each of two samples with (U)SAXS and XRD techniques, nm-sized pores are mainly interparticle ones in the higher calcite regions, where the porosity is also relatively lower, while the lower calcite regions consist of both interparticle and intraparticle pore types with higher porosity. Lastly, the μXRF and (U)SAXS mappings are combined to generate porosity distribution maps to provide more insights about sample heterogeneity related to the laminations and fractures at our observational scales.

58 GEOSCIENCES↗

Major to trace element imaging and analysis of iron age glasses using stage scanning in the analytical dual beam microscope (tandem)

Dark and clear silicate glasses formed during an iron age vitrification event ≈ 1500 years ago at the Broborg hillfort near Uppsala, Sweden have been analyzed using a scanning electron microscope equipped with a micro-X-ray fluorescence (μXRF) spectrometer. Correlated µXRF and electron beam-induced energy dispersive spectrometry (EDS) X-ray maps were collected via stage-scanning at constant velocity. This coupled procedure represents a new approach for the cultural heritage community to conduct analytical studies of archaeometric specimens composed of metal, ceramic, or mixed inorganic/organic materials, where major and trace element compositions are registered in space for areas up to the centimeter-length scale at micrometer-scale resolution. Overview images were used to select areas for EDS beam scan maps correlated with multispectral cathodoluminescence (CL) imaging and co-located quantitative EDS and μXRF point analysis. Fe, Ca, Mg, Ti, P, Mn, Zr, Zn, and Y are enriched in the dark glass, while Si, Al, K, Na, Ba, Sr, Rb, and Ga are enriched in the clear glass. Unmelted material is comprised predominately of quartz (SiO 2 ) along with trace apatite (Ca 5 (PO 4 ) 3 [Cl,OH]) and zircon (ZrSiO 4 ). Multivariate statistical analysis was used to measure the area fractions of high variance components while lower variance components represented phase mixtures. Differences between calculated melt viscosities for the glass compositions are consistent with field and laboratory observations. Coupled large area EDS and μXRF imaging shows significant promise for informed selection of higher spatial resolution and higher sensitivity follow-up studies, e.g., those performed using synchrotron analysis.

36 MATERIALS SCIENCE↗

Applicability of Micro X-Ray Fluorescence Spectroscopy to Astromaterials Curation and Research

Introduction: The Astromaterials Acquisition and Curation Office at NASA’s Johnson Space Center (JSC) curates NASA’s astromaterial sample collections which includes: Apollo samples, Luna samples, Ant-arctic meteorites, cosmic dust particles, microparticle impacts into space-flown materials, Genesis solar wind atoms, Stardust comet Wild-2 particles, Stardust inter-stellar particles, Hayabusa asteroid Itokawa particles, Hayabusa 2 asteroid Ryugu particles, and future OSIRIS-Rex asteroid Bennu particles (landing in Sep-tember, 2023) [1–3]. To enhance JSC’s advanced cu-ration capabilities, we have recently installed a high-performance micro-X-ray fluorescence (µXRF) spec-trometer to assist in sample characterization through rapid, non-destructive, in-situ elemental analyses that do not require the sample preparation protocols (i.e., polishing and carbon-coating) commonly needed for electron beam analyses. With this new instrument, we are capable of detecting all elements down to carbon in a variable-pressure or He-purged chamber for anal-ysis of a wide range of sample types. Here we describe the instrumental set-up, capabilities, and applicability of µXRF analysis to astromaterials curation and re-search. Instrumentation and Methodology: The X-ray fluorescence and computed tomography lab (X-FaCT) lab at JSC is now equipped with a Bruker M4 Tornado Plus µXRF (Fig. 1). This system is an energy-dispersive x-ray spectrometer equipped with two 60 mm2 silicon drift detectors (SDD) that are able to be used simulta-neously for output count rates ~500,000 cps. New light element windows allow detecting and analyzing the entire elemental range from carbon to americium. Two x-ray tubes (micro-focus Rh with polycapillary lenses and W with collimators of 0.5, 1.0, 2.0, and 4.5 mm) with max excitation parameters of 50 kV, 30 W and 50 kV, 40 W, respectively, allow for more flexibility of the analysis of high energy lines. The motorized X-Y-Z stage has a mapping range of 190 x 160 mm and can support samples up to 7 kg (~15.5 lbs) and a height of 120 mm [4]. Analytical modes include elemental analysis (down to ~20 µm spot size) via point, line, or area of bulk materials (rock surfaces, thin sections, thick sections, etc.) as well as coating analysis (determination of thickness and composition) of samples. This system has a variable vacuum chamber (1 mbar to 1 atm) that is also equipped with a He-purge system which accommodates vacuum sensitive samples while still allowing detection of light elements at atmospheric pressure. Utility and Applicability of µXRF in Astro-materials research and exploration science (ARES): Elemental analysis using µXRF is commonly em-ployed for both terrestrial and planetary geological science disciplines [5]. It is especially useful for analy-sis of astromaterials given the limited sample prepara-tion required, which is not feasible for certain materi-als. Here we show select applications of µXRF anal-yses of astromaterials that can, have, and will be done at JSC’s X-FaCT lab. Point analysis: In-situ spot analyses (~20 µm spot size) on a cut slab of Martian meteorite NWA 10922 allowed for the discovery, qualitative elemental analy-sis and determination of different feldspar minerals [6]. These point analyses served as an effective prelim-inary step for subsequent quantitative analyses. Ana-lytical standards can be employed for more accurate quantification of µXRF spot analyses. Area analysis: This analytical mode measures all detectable elements (from C to Am) at each pixel (>5 µm pixel size) in a user-defined area. The results are shown as elemental maps which can be extracted as 16-bit TIFF’s for further data processing. In Fig. 2. we show elemental distribution maps of the high-Ti basalt 73001,531 that have been processed using ImageJ software. From these maps you can accurately and quickly (this map took ~50 mins.) identify mineral components, such as pyroxene, plagioclase, oxides, and phosphates, compositional zoning, and mineral textures. Detection of high-Z phases: µXRF techniques are es-pecially effective at analyzing trace minerals with high-atomic-number (high-Z) elements because the high-energy characteristic X-rays used (relative to SEM EDS) allow for mapping of K lines in elements up to La (typically SEM maps use L X-ray lines for elements >Zn, and these can often have interferences). Thus, µXRF is especially suited for identifying minerals like zircon, baddeleyite, REE-rich phosphates, Fe-rich met-als, oxides, sulfides, and phosphides [4]. In Fig. 3 we show elemental distribution maps for 73001,530 where we are able to correlate the original video image with, Zr, Si, Y and Hf elemental maps together identi-fying the location of a zircon. In this location you would expect lower Si compared to surrounding mate-rial, as well as higher Zr, Y, and Hf content compared to surrounding material, all of which is confirmed by our XRF ele-mental distribution maps (Figure 2.) Conclusions: The new M4 Tornado Plus µXRF within the Astromaterials Acquisition and Curation office at NASA JSC allows for rapid and non-destructive elemental analysis of astromaterials with limited or no sample preparation. µXRF analyses pro-vide crucial compositional knowledge for the prelimi-nary examination and curation of astromaterials. This instrument enhances the advanced curation capabili-ties in the X-FaCT laboratory at JSC by allowing pro-ductive, cohesive, and non-destructive multi-modal x-ray analyses on astromaterial samples, which is neces-sary for the comprehensive curation and study of our current and future astromaterial collections. Addition-ally, µXRF can provide complimentary information to researchers for studies on astromaterials. References: [1] Allen, C. et al., (2011). Chemie De Erde Geochemistry, 71, 1-20. [2] McCubbin, F. M. et al., (2016) 47th LPSC, abstract #2668 [3] Zeigler, R. A. et al., (2017) 48th LPSC, abstract #2772 [4] Bruker User Manual [5] Young et al., (2016) Appl. Geochemistry, 72, 77-87 [6] Mor-ris, R. V. et al., (2023) 54th LPSC.

E W O'Neal↗

Multimodal, microspectroscopic speciation of legacy phosphorus in two US mid-Atlantic agricultural soils

To understand phosphorus (P) mobility in agricultural soils and its potential environmental risk, it is essential to directly measure solid phase P speciation. Often, bulk P K-edge X-ray absorption near edge structure (XANES) spectroscopy followed by linear combination fitting (LCF) is utilized to determine the solid P phases in soil. However, this method may limit results to only a few major phases. Additionally, XANES spectra for different P species may have very similar features, leading to an over- or underestimate of their contribution to LCF. Here, an improved P speciation by pairing multimodal microbeam-X-ray fluorescence (µ-XRF) mapping coupled with µ-XANES (microbeam-X-ray absorption near edge structure) analysis to directly speciate major and minor P phases on the micron scale is provided. We combined maps of both tender (P, sulfur, aluminum, and silicon) and hard energy (calcium, iron [Fe], and manganese) elements to evaluate the elemental co-locations with P. To better account for uncertainty assigning XANES peaks to individual compounds, a more quantitative fingerprinting by “spectral feature analysis” was completed. With this analysis, an R-factor is reported for the fit. These results were compared to traditional LCF. Pre-edge fitting results revealed the presence of a two-component pre-edge feature for phosphate adsorbed to ferrihydrite. Additionally, phytate co-precipitated with ferrihydrite (Phytate-Fe-Cop) had a pre-edge feature, indicating direct association with Fe. Lastly, a unique P species associated with manganese oxide was identified in the soil via multimodal mapping and µ-XANES. These results allow for better prediction of P dissolution and mobility.

36 MATERIALS SCIENCE↗