Search NASA⌕ Search

SEARCH · Search NASA

Results for “2D SCANS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Atomic-Scale Insights into the Lateral and Vertical Epitaxial Growth in Two-Dimensional Pd 2 Se 3 –MoS 2 Heterostructures

Two-dimensional (2D) materials form heterostructures in both the lateral and vertical directions when two different materials are interfaced, but with totally different bonding mechanisms of covalent in-plane to van der Waal’s layered interactions. Understanding how the competition between lateral and vertical forces influences the epitaxial growth is important for future materials development of complex mixed layered heterostructures. In this study, we use atomic-resolution annular dark-field scanning transmission electron microscopy to study the detailed atomic arrangements at mixed 2D heterostructure interfaces composed of two semiconductors with distinctly different crystal symmetry and elemental composition, Pd 2 Se 3 :MoS 2 , in order to understand the role of different chemical bonds on the resultant epitaxy. Pd 2 Se 3 is grown off the step edge in bilayer MoS 2 , and the vertical and lateral epitaxial relationships of the Pd 2 Se 3 –MoS 2 heterostructures are investigated. We find that the similarity of geometry at the interface with one metal (Pd or Mo) atoms bonded with two chalcogens (S or Se) are the crucial factors to make the atomically stitched lateral junction of 2D heterostructures. In addition, the vertical van der Waal interactions that are normally dominant in layered materials can be overcome by in-plane forces if the interfacial atomic stitching is high in quality and low in defect density. This knowledge should help guide the approaches for improving the epitaxy in mixed 2D heterostructures and seamless stitching of in-plane 2D heterostructures with various complex monolayer structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Impedance Humidity Sensor Based on CVD Grown WSe 2 2D Films

2D materials-based planar devices have been sought after for gas and humidity sensor applications owing to their high sensitivity due to their ultrathin nature and increased surface area. Herein, 2D WSe 2 films-based planner devices were fabricated to evaluate their performance for potential application in humidity sensors. The structure and morphology of the WSe 2 sensing films were studied by Raman spectroscopy, photoluminescence, optical microscopy, and scanning electron microscopy (SEM) techniques. The relative humidity-dependent sensing performances of the 2D WSe 2 films were evaluated using current–voltage (I–V), relative impedance, and complex total impedance (electrochemical impedance spectroscopy, EIS) techniques. This sensor showed a very stable and repeatable performance investigated over the period of 18 months. The response and recovery times of the WSe 2 -based impedance sensors were found to be 40 and 30 s, respectively. The WSe 2 sensor exhibits a 2 ± 1% minimum hysteresis at a lower humidity level (50% RH) and around 8 ± 2% maximum hysteresis at relative humidity level (70% RH). This value of hysteresis is in the acceptable range during the initial investigation of any material to explore its potential for application in humidity sensors. The density functional theory (DFT) analysis was performed with the interaction from water molecules of the WSe 2 sample for a better understanding of the sensing mechanism of devices.

2D- WSe2↗

The Atomic Drill Bit: Precision Controlled Atomic Fabrication of 2D Materials

The ability to deterministically fabricate nanoscale architectures with atomic precision is the central goal of nanotechnology, whereby highly localized changes in the atomic structure can be exploited to control device properties at their fundamental physical limit. Here, an automated, feedback-controlled atomic fabrication method is reported and the formation of 1D–2D heterostructures in MoS 2 is demonstrated through selective transformations along specific crystallographic orientations. The atomic-scale probe of an aberration-corrected scanning transmission electron microscope (STEM) is used, and the shape and symmetry of the scan pathway relative to the sample orientation are controlled. The focused and shaped electron beam is used to reliably create Mo 6 S 6 nanowire (MoS-NW) terminated metallic-semiconductor 1D–2D edge structures within a pristine MoS 2 monolayer with atomic precision. From these results, it is found that a triangular beam path aligned along the zig-zag sulfur terminated (ZZS) direction forms stable MoS-NW edge structures with the highest degree of fidelity without resulting in disordering of the surrounding MoS 2 monolayer. Density functional theory (DFT) calculations and ab initio molecular dynamic simulations (AIMD) are used to calculate the energetic barriers for the most stable atomic edge structures and atomic transformation pathways. These discoveries provide an automated method to improve understanding of atomic-scale transformations while opening a pathway toward more precise atomic-scale engineering of materials.

2D materials↗

Charge density waves in two-dimensional transition metal dichalcogenides

Charge density wave (CDW is one of the most ubiquitous electronic orders in quantum materials. While the essential ingredients of CDW order have been extensively studied, a comprehensive microscopic understanding is yet to be reached. Recent research efforts on the CDW phenomena in two-dimensional (2D) materials provide a new pathway toward a deeper understanding of its complexity. This review provides an overview of the CDW orders in 2D with atomically thin transition metal dichalcogenides (TMDCs) as the materials platform. We mainly focus on the electronic structure investigations on the epitaxially grown TMDC samples with angle-resolved photoemission spectroscopy and scanning tunneling microscopy/spectroscopy as complementary experimental tools. Finally, we discuss the possible origins of the 2D CDW, novel quantum states coexisting with them, and exotic types of charge orders that can only be realized in the 2D limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-G-TeP4-04: An Automated Monte Carlo Based QA Framework for Pencil Beam Scanning Treatments

Purpose: Prior to treating new PBS field, multiple (three) patient-field-specific QA measurements are performed: two 2D dose distributions at shallow depth (M1) and at the tumor depth (M2) with treatment hardware at zero gantry angle; one 2D dose distribution at iso-center (M3) without patient specific devices at the planned gantry angle. This patient-specific QA could be simplified by the use of MC model. The results of MC model commissioning for a spot-scanning system and the fully automated TOPAS/MC-based QA framework will be presented. Methods: We have developed in-house MC interface to access a TPS (Astroid) database from a computer cluster remotely. Once a plan is identified, the interface downloads information for the MC simulations, such as patient images, apertures points, and fluence maps and initiates calculations in both the patient and QA geometries. The resulting calculations are further analyzed to evaluate the TPS dose accuracy and the PBS delivery. Results: The Monte Carlo model of our system was validated within 2.0 % accuracy over the whole range of the dose distribution (proximal/shallow part, as well as target dose part) due to the location of the measurements. The averaged range difference after commissioning was 0.25 mm over entire treatment ranges, e.g., 6.5 cm to 31.6 cm. Conclusion: As M1 depths range typically from 1 cm to 4 cm from the phantom surface, The Monte Carlo model of our system was validated within +− 2.0 % in absolute dose level over a whole treatment range. The averaged range difference after commissioning was 0.25 mm over entire treatment ranges, e.g., 6.5 cm to 31.6 cm. This work was supported by NIH/NCI under CA U19 21239.

60 APPLIED LIFE SCIENCES↗

Time-Resolved Electrical Scanning Probe Microscopy of Layered Perovskites Reveals Spatial Variations in Photoinduced Ionic and Electronic Carrier Motion

We study light-induced dynamics in thin films comprising Ruddlesden–Popper phases of the layered 2D perovskite (C 4 H 9 NH 3 ) 2 PbI 4 . We probe ionic and electronic carrier dynamics using two complementary scanning probe methods, time-resolved G-mode Kelvin probe force microscopy and fast free time-resolved electrostatic force microscopy, as a function of position, time, and illumination. Here, we show that the average surface photovoltage sign is dominated by the band bending at the buried perovskite–substrate interface. However, the film exhibits substantial variations in the spatial and temporal response of the photovoltage. Under illumination, the photovoltage equilibrates over hundreds of microseconds, a time scale associated with ionic motion and trapped electronic carriers. Surprisingly, we observe that the surface photovoltage of the 2D grain centers evolves more rapidly in time than at the grain boundaries. We propose that the slower evolution at grain boundaries is due to a combination of ion migration occurring between PbI 4 planes, as well as electronic carriers traversing grain boundary traps, thereby changing the time-dependent band unbending at grain boundaries. These results provide a model for the photoinduced dynamics in 2D perovskites and are a useful basis for interpreting photovoltage dynamics on hybrid 2D/3D structures.

14 SOLAR ENERGY↗

Electronic, vibrational, Raman, and scanning tunneling microscopy signatures of two-dimensional boron nanomaterials

Compared to graphene, the synthesis of large area atomically thin boron materials is particularly challenging, owing to the electronic shell structure of B, which does not lend itself to the straightforward assembly of pure B materials. This difficulty is evidenced by the fact that the first synthesis of a pure two-dimensional boron was only very recently reported, using silver as a growing substrate. In addition to experimentally observed 2D boron allotropes, a number of other stable and metastable 2D boron materials are predicted to exist, depending on growth conditions and the use of a substrate during growth. This first-principles study based on density functional theory aims at providing guidelines for the identification of these materials. To this end, this report presents a comparative description of a number of possible 2D B allotropes. Electronic band structures, phonon dispersion curves, Raman scattering spectra, and scanning tunneling microscopy images are simulated to highlight the differences between five distinct realizations of these B systems. In conclusion, this study demonstrates the existence of clear experimental signatures that constitute a solid basis for the unambiguous experimental identification of layered B materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Small energy gap revealed in CrBr 3 by scanning tunneling spectroscopy

CrBr 3 is a layered van der Waals material with magnetic ordering down to the 2D limit. For decades, based on optical measurements, it is believed that the energy gap of CrBr 3 is in the range of 1.68–2.1 eV. However, controversial results have indicated that the band gap of CrBr 3 is possibly smaller than that. An unambiguous determination of the energy gap is critical to the correct interpretations of the experimental results of CrBr 3 . Here, we present the scanning tunneling microscopy and spectroscopy (STM/S) results of CrBr 3 thin and thick flakes exfoliated onto highly ordered pyrolytic graphite (HOPG) surfaces and density functional theory (DFT) calculations to reveal the small energy gap (peak-to-peak energy gap to be 0.57 ± 0.04 eV; or the onset signal energy gap to be 0.29 ± 0.05 eV from dI/dV spectra). Atomic resolution topography images show the defect-free crystal structure and the dI/dV spectra exhibit multiple peak features measured at 77 K. The conduction band – valence band peak pairs in the multi-peak dI/dV spectrum agree very well with all reported optical transitions. STM topography images of mono- and bi-layer CrBr 3 flakes exhibit edge degradation due to short air exposure (~15 min) during sample transfer. The unambiguously determined small energy gap settles the controversy and is the key in better understanding CrBr 3 and similar materials.

36 MATERIALS SCIENCE↗

Damage imaging using Lamb waves for SHM applications

2-D ultrasonic arrays, due to their beam-steering capability and all azimuth angle coverage are a very promising tool for the inspection of plate-like structures using Lamb waves (LW). Contrary to the classical linear phased arrays (PAs) the 2D arrays enable unequivocal defect localization and they are even capable of mode selectivity of the received LWs . Recently, it has been shown that multistatic synthetic focusing (SF) algorithms applied for 2D arrays are much more effective than the classical phase array mode commonly used in NDT. The multistatic SF assumes multiple transmissions of elements in a transmitting aperture and off-line processing of the data acquired by a receiving aperture. In the simplest implementation of the technique, only a single multiplexed input and a number of output channels are required, which results in significant hardware simplification compared with the PA systems. On the one hand implementation of the multistatic SF to 2D arrays creates additional degrees of freedom during the design of the array topology, which complicates the array design process. On the other hand, it enables designing sparse arrays with performance similar to that of the fully populated dense arrays. In this paper we present a general systematic approach to the design and optimization of imaging systems based on the 2D array operating in the multistatic mode. We start from presenting principles of the SF schemes applied to LW imaging. Then, we outline the coarray concept and demonstrate how it can be used for reducing number of elements of the 2D arrays. Finally, efficient tools for the investigation and experimental verification of the designed 2D array prototypes are presented. The first step in the investigation is theoretical evaluation performed using frequency-dependent structure transfer function (STF), which enables approximate simulation of an array excited with a tone-burst in a dispersive medium. Finally, we show how scanning laser vibrometer, sensing waves in multiple points corresponding to the locations of the 2D receiving array elements, can be used as a tool for rapid experimental verification of the developed topologies. The presented methods are discussed in terms of the beampatterns and sparse versions of the fully populated array topologies are be presented. The effect of apodization applied to the array elements is also investigated. Both simulated and experimental results are included.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-D-BRC-03: Development and Validation of an Online 2D Dose Verification System for Daily Patient Plan Delivery Accuracy Check

Purpose: All plan verification systems for particle therapy are designed to do plan verification before treatment. However, the actual dose distributions during patient treatment are not known. This study develops an online 2D dose verification tool to check the daily dose delivery accuracy. Methods: A Siemens particle treatment system with a modulated scanning spot beam is used in our center. In order to do online dose verification, we made a program to reconstruct the delivered 2D dose distributions based on the daily treatment log files and depth dose distributions. In the log files we can get the focus size, position and particle number for each spot. A gamma analysis is used to compare the reconstructed dose distributions with the dose distributions from the TPS to assess the daily dose delivery accuracy. To verify the dose reconstruction algorithm, we compared the reconstructed dose distributions to dose distributions measured using PTW 729XDR ion chamber matrix for 13 real patient plans. Then we analyzed 100 treatment beams (58 carbon and 42 proton) for prostate, lung, ACC, NPC and chordoma patients. Results: For algorithm verification, the gamma passing rate was 97.95% for the 3%/3mm and 92.36% for the 2%/2mm criteria. For patient treatment analysis,the results were 97.7%±1.1% and 91.7%±2.5% for carbon and 89.9%±4.8% and 79.7%±7.7% for proton using 3%/3mm and 2%/2mm criteria, respectively. The reason for the lower passing rate for the proton beam is that the focus size deviations were larger than for the carbon beam. The average focus size deviations were −14.27% and −6.73% for proton and −5.26% and −0.93% for carbon in the x and y direction respectively. Conclusion: The verification software meets our requirements to check for daily dose delivery discrepancies. Such tools can enhance the current treatment plan and delivery verification processes and improve safety of clinical treatments.

60 APPLIED LIFE SCIENCES↗

Few-view computed tomography reconstruction using deep neural network inference

A system for generating 2D slices of a 3D image of a target volume is provided. The system receives a target sinogram collected during a computed tomography scan of the target volume. The system inputs the target sinogram to a convolutional neural network (CNN) to generate predicted 2D slices of the 3D image. The CNN is trained using training 2D slices of training 3D images. The system initializes 2D slices to the predicted 2D slices. The system reconstructs 2D slices of the 3D image from the target sinogram and the initialized 2D slices.

Kim, Hyojin↗

A study of a sector spectrophotometer and auroral O+(2P-2D) emissions

The metastable O+(2P-2D) auroral emission was investigated. The neighboring OH contaminants and low intensity levels of the emission itself necessitated the evolution of an instrument capable of separating the emission from the contaminants and having a high sensitivity in the wavelength region of interest. A new type of scanning photometer was developed and its properties are discussed. The theoretical aspects of auroral electron interaction with atomic oxygen and the resultant O+(2P-2D) emissions were examined in conjunction with N2(+)1NEG emissions. Ground based measurements of O+(2P-2D) auroral emission intensities were made using the spatial scanning photometer (sector spectrophotometer). Simultaneous measurements of N2(+)1NEG sub 1,0 emission intensity were made in the same field of view using a tilting photometer. Time histories of the ratio of these two emissions made in the magnetic zenith during auroral breakup periods are given. Theories of I sub 7319/I sub 4278 of previous investigators were presented. A rocket measurement of N2(+)1NEG sub 0,0 and O+(2P-2D) emission in aurora was examined in detail and was found to agree with the ground based measurements. Theoretical examination resulted in the deduction of the electron impact efficiency generating O+(2P) and also suggests a large source of O+(2P) at low altitude. A possible source is charge exchange of N+(1S) with OI(3P).

Swenson, G. R.↗

Local Neutral Density and Plasma Parameter Measurements in a Hollow Cathode Plume

In order to understand the cathode and keeper wear observed during the Extended Life Test (ELT) of the DS1 flight spare NSTAR thruster and provide benchmarking data for a 2D cathode/cathode-plume model, a basic understanding of the plasma and neutral gas parameters in the cathode orifice and keeper region of the cathode plume must be obtained. The JPL cathode facility is instrumented with an array of Langmuir probe diagnostics along with an optical diagnostic to measure line intensity of xenon neutrals. In order to make direct comparisons with the present model, a flat plate anode arrangement was installed for these tests. Neutral density is deduced from the scanning probe data of the plasma parameters and the measured xenon line intensity in the optical regime. The Langmuir probes are scanned both axially, out to 7.0 cm downstream of the keeper, and radially to obtain 2D profile of the plasma parameters. The optical fiber is housed in a collimating stainless steel tube, and is scanned to view across the cathode plume along cuts in front of the keeper with a resolution of 1.5 mm. The radial intensities are unfolded using the Abel inversion technique that produces radial profiles of local neutral density. In this paper, detailed measurements of the plasma parameters and the local neutral densities will be presented in the cathode/keeper plume region for a 1.5 cm diameter NEXIS cathode at 25A of discharge current at several different strengths of applied magnetic field.

Plasma density↗

Effect of Forest Canopy on Remote Sensing Soil Moisture at L-band

Global maps of soil moisture are needed to improve understanding and prediction of the global water and energy cycles. Accuracy requirements imply the use of lower frequencies (L-band) to achieve adequate penetration into the soil and to minimize attenuation by the vegetation canopy and effects of surface roughness. Success has been demonstrated over agricultural areas, but canopies with high biomass (e.g. forests) still present a challenge. Examples from recent measurements over forests with the L-band radiometer, 2D-STAR, and its predecessor, ESTAR, will be presented to illustrate the problem. ESTAR and 2D-STAR are aircraft-based synthetic aperture radiometers developed to help resolve both the engineering and algorithm issues associated with future remote sensing of soil moisture. ESTAR, which does imaging across track, was developed to demonstrate the viability of aperture synthesis for remote sensing. The instrument has participated several soil moisture experiments (e.g. at the Little Washita Watershed in 1992 and the Southern Great Plains experiments in 1997 and 1999). In addition, measurements have been made at a forest site near Waverly, VA which contains conifer forests with a variety of biomass. These data have demonstrated the success of retrieving soil moisture at L-band over agricultural areas and the response of passive observations at L-band to biomass over forests. 2D-STAR is a second generation instrument that does aperture synthesis in two dimensions (along track and cross track) and is dual polarized. This instrument has the potential to provide measurements at L-band that simulate the measurements that will be made by the two L-band sensors currently being developed for future remote sensing of soil moisture from space: Hydros (conical scan and real aperture) and SMOS (multiple incidence angle and synthetic aperture). 2D-STAR participated in the SMEX-03 soil moisture experiment, providing images from the NASA P-3 aircraft. Preliminary results include images of the experiment site area near Huntsville, AL that included a mixture of forest and agriculture. Changes during a rain event further illustrate the issues presented by forests. Work is continuing to reduce the 2D-STAR data and to support the two future remote sensing missions. Among the goals is to process the 2D-STAR data to create multiple looks (at the same pixel) with different incidence angles. Data in this format can be used to test algorithms for retrieving soil moisture and biomass such as are planned for SMOS. Also, the data are being processed to provide images at constant incidence angles such as will be obtained by Hydros. Although Hydros will have only one incidence angle, it will also carry an L-band radar, The goal is to use the radar to improve spatial resolution, an issue for remote sensing from space at the long wavelengths. Simultaneous observations with active and passive sensors also offers interesting prospects for treating areas of high biomass (forests) and irregular terrain and may be the challenge for the future.

LeVine, D. M.↗

Patient-Specific Quality Assurance for Prostate Cancer Patients Receiving Spot Scanning Proton Therapy Using Single-Field Uniform Dose

Purpose: To describe our experiences with patient-specific quality assurance (QA) for patients with prostate cancer receiving spot scanning proton therapy (SSPT) using single-field uniform dose (SFUD). Methods and Materials: The first group of 249 patients with prostate cancer treated with SSPT using SFUD was included in this work. The scanning-beam planning target volume and number of monitor units were recorded and checked for consistency. Patient-specific dosimetric measurements were performed, including the point dose for each plan, depth doses, and two-dimensional (2D) dose distribution in the planes perpendicular to the incident beam direction for each field at multiple depths. The {gamma}-index with 3% dose or 3-mm distance agreement criteria was used to evaluate the 2D dose distributions. Results: We observed a linear relationship between the number of monitor units and scanning-beam planning target volume. The difference between the measured and calculated point doses (mean {+-} SD) was 0.0% {+-} 0.7% (range, -2.9% to 1.8%). In general, the depth doses exhibited good agreement except at the distal end of the spread-out Bragg peak. The pass rate of {gamma}-index (mean {+-} SD) for 2D dose comparison was 96.2% {+-} 2.6% (range, 90-100%). Discrepancies between the measured and calculated dose distributions primarily resulted from the limitation of the model used by the treatment planning system. Conclusions: We have established a patient-specific QA program for prostate cancer patients receiving SSPT using SFUD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A GEM readout with radial zigzag strips and linear charge-sharing response

Here, we study the position sensitivity of radial zigzag strips intended to read out large GEM detectors for tracking at future experiments. Zigzag strips can cover a readout area with fewer strips than regular straight strips while maintaining good spatial resolution. Consequently, they can reduce the number of required electronic channels and related cost for large-area GEM detector systems. A non-linear relation between incident particle position and hit position measured from charge sharing among zigzag strips was observed in a previous study. We significantly reduce this non-linearity by improving the interleaving of adjacent physical zigzag strips. Zigzag readout structures are implemented on PCBs and on a flexible foil and are tested using a 10 cm × 10 cm triple-GEM detector scanned with a strongly collimated X-ray gun on a 2D motorized stage. Lastly, angular resolutions of 60–84 μrad are achieved with a 1.37 mrad angular strip pitch at a radius of 784 mm. On a linear scale this corresponds to resolutions below 100 μm.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a cost effective surface-patterned transparent conductive coating as top-contact of light emitting diodes

Sol-gel process has been used to form indium zinc oxide films using an optimized combination of zinc to indium concentration in the precursor solutions. Different structures, like one (1D) and two-dimensional (2D) gratings and diffractive optical elements (DOEs) in the form of Fresnel lens are fabricated on the film surface of proposed top metal contact of LED by imprint soft lithography technique. These structures can enhance the LED's light extraction efficiency (LEE) or can shape the output beam pattern, respectively. Several characterizations are done to analyze the material and structural properties of the films. The presence of 1D and 2D gratings as well as DOEs is confirmed from field emission scanning electron and atomic force microscopes analyses. Although, X-ray diffraction shows amorphous nature of the film, but transmission electron microscopy study shows that it is nano crystalline in nature having fine particles (∼8 nm) of hexagonal ZnO. Shrinkage behaviour of gratings as a function of curing temperature is explained by Fourier transform infra-red spectra and thermo gravimetric-differential thermal analysis. The visible transmission and sheet resistance of the sample are found comparable to tin doped indium oxide (ITO). Therefore, the film can compete as low cost substitute of ITO as top metal contact of LEDs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Internal margin assessment using cine MRI analysis of deglutition in head and neck cancer radiotherapy

Purpose: Intensity-modulated radiation therapy (IMRT) is a promising treatment modality for patients with head and neck cancer (HNC). The dose distributions from IMRT are static and, thus, are unable to account for variations and/or uncertainties in the relationship between the patient (region being treated) and the beam. Organ motion comprises one such source of this uncertainty, introduced by physiological variation in the position, size, and shape of organs during treatment. In the head and neck, the predominant source of this variation arises from deglutition (swallowing). The purpose of this study was to investigate whether cinematographic MRI (cine MRI) could be used to determine asymmetric (nonuniform) internal margin (IM) components of tumor planning target volumes based on the actual deglutition-induced tumor displacement. Methods: Five head and neck cancer patients were set up in treatment position on a 3 T MRI scanner. Two time series of single-slice, sagittal, cine images were acquired using a 2D FLASH sequence. The first time series was a 12.8 min scan designed to capture the frequency and duration of deglutition in the treatment position. The second time series was a short, 15 s scan designed to capture the displacement of deglutition in the treatment position. Deglutition frequency and mean swallow duration were estimated from the long time series acquisition. Swallowing and resting (nonswallowing) events were identified on the short time series acquisition and displacement was estimated based on contours of gross tumor volume (GTV) generated at each time point of a particular event. A simple linear relationship was derived to estimate 1D asymmetric IMs in the presence of resting- and deglutition-induced displacement. Results: Deglutition was nonperiodic, with frequency and duration ranging from 2.89-24.18 mHz and from 3.86 to 6.10 s, respectively. The deglutition frequency and mean duration were found to vary among patients. Deglutition-induced maximal GTV displacements ranged from 0.00 to 28.36 mm with mean and standard deviation of 4.72{+-}3.18, 3.70{+-}2.81, 2.75{+-}5.24, and 10.40{+-}10.76 mm in the A, P, I, and S directions, respectively. Resting-induced maximal GTV displacement ranged from 0.00 to 5.59 mm with mean and standard deviation of 3.01{+-}1.80, 1.25{+-}1.10, 3.23+2.20, and 2.47{+-}1.11 mm in the A, P, I, and S directions, respectively. For both resting and swallowing states, displacement along the S-I direction dominated displacement along the A-P direction. The calculated IMs were dependent on deglutition frequency, ranging from 3.28-4.37 mm for the lowest deglutition frequency patient to 3.76-6.43 mm for the highest deglutition frequency patient. A statistically significant difference was detected between IMs calculated for P and S directions (p=0.0018). Conclusions: Cine MRI is able to capture tumor motion during deglutition. Swallowing events can be demarcated by MR signal intensity changes caused by anatomy containing fully relaxed spins that move medially into the imaging plane during deglutition. Deglutition is nonperiodic and results in dynamic changes in the tumor position. Deglutition-induced displacements are larger and more variable than resting displacements. The nonzero mean maximum resting displacement indicates that some tumor motion occurs even when the patient is not swallowing. Asymmetric IMs, derived from deglutition frequency, duration, and directional displacement, should be employed to account for tumor motion in HNC RT.

60 APPLIED LIFE SCIENCES↗