Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Development of Weigh-out Process and Evaluations for Underwater Partial Gravity Simulations

For the upcoming Artemis lunar missions, astronauts will need to train in a spacesuit where partial gravity can be simulated such as the NASA Neutral Buoyancy Lab (NBL). At the NBL, dive weights and foam can be added around the spacesuit to attain a satisfactory center of buoyancy (CB) and center of gravity (CG) location to simulate the lunar gravity (1/6thG) effects. If CG and CB are not co-located properly, incorrect righting moments can be introduced, and both simulation quality and EVA task performance can be impaired. Based on the findings from the initial testing using xEMU spacesuits, it was observed that the weigh-out method (i.e., determination of the weights and foam quantities and position) needed further development to improve the simulation quality, especially for the subjects who experienced excessive instability. This paper aims to present the on-going effort to improve the weigh-out process for enabling NBL lunar EVA simulations. For this effort, a human-suit model was created to use suit CAD and 3D human body scans to estimate both CB and CG location for each suited subject. NBL weigh-out testing was performed to characterize the effects of CG and CB positioning, in which the 3D human-suit model was used to determine optimal weigh-out combinations of weights and foam. Postural, balance, and subjective feedback were gathered for each weigh-out configuration. The results indicated that, as the CB was shifted higher and the CB and CG located closer to each other, the subject tended to be more stable and their EVA performance improved. A high CB location was then prioritized across 4 additional subjects in both small and large size spacesuits. When compared to the initial xEMU test series, improved performance was observed across all subjects as the CB moved higher and aligned closer to the system CG.

Pouyan Sabahi↗

Development of Weigh-out Process and Evaluations for Underwater Partial Gravity Simulations

For the upcoming Artemis lunar missions, astronauts will need to train in a spacesuit where partial gravity can be simulated such as the NASA Neutral Buoyancy Lab (NBL). At the NBL, dive weights and foam can be added around the spacesuit to attain a satisfactory center of buoyancy (CB) and center of gravity (CG) location to simulate the lunar gravity (1/6thG) effects. If CG and CB are not co-located properly, incorrect righting moments can be introduced, and both simulation quality and EVA task performance can be impaired. Based on the findings from the initial testing using xEMU spacesuits, it was observed that the weigh-out method (i.e., determination of the weights and foam quantities and position) needed further development to improve the simulation quality, especially for the subjects who experienced excessive instability. This paper aims to present the on-going effort to improve the weigh-out process for enabling NBL lunar EVA simulations. For this effort, a human-suit model was created to use suit CAD and 3D human body scans to estimate both CB and CG location for each suited subject. NBL weigh-out testing was performed to characterize the effects of CG and CB positioning, in which the 3D human-suit model was used to determine optimal weigh-out combinations of weights and foam. Postural, balance, and subjective feedback were gathered for each weigh-out configuration. The results indicated that, as the CB was shifted higher and the CB and CG located closer to each other, the subject tended to be more stable and their EVA performance improved. A high CB location was then prioritized across 4 additional subjects in both small and large size spacesuits. When compared to the initial xEMU test series, improved performance was observed across all subjects as the CB moved higher and aligned closer to the system CG.

Pouyan Sabahi↗

Development of Weigh-Out Process and Evaluations for Underwater Partial Gravity Simulations

For the upcoming Artemis lunar missions, astronauts will need to train in a spacesuit where partial gravity can be simulated such as the NASA Neutral Buoyancy Lab (NBL). At the NBL, dive weights and foam can be added around the spacesuit to attain a satisfactory center of buoyancy (CB) and center of gravity (CG) location to simulate the lunar gravity (1/6thG) effects. If CG and CB are not co-located properly, incorrect righting moments can be introduced, and both simulation quality and EVA task performance can be impaired. Based on the findings from the initial testing using xEMU spacesuits, it was observed that the weigh-out method (i.e., determination of the weights and foam quantities and position) needed further development to improve the simulation quality, especially for the subjects who experienced excessive instability. This paper aims to present the on-going effort to improve the weigh-out process for enabling NBL lunar EVA simulations. For this effort, a human-suit model was created to use suit CAD and 3D human body scans to estimate both CB and CG location for each suited subject. NBL weigh-out testing was performed to characterize the effects of CG and CB positioning, in which the 3D human-suit model was used to determine optimal weigh-out combinations of weights and foam. Postural, balance, and subjective feedback were gathered for each weigh-out configuration. The results indicated that, as the CB was shifted higher and the CB and CG located closer to each other, the subject tended to be more stable and their EVA performance improved. A high CB location was then prioritized across 4 additional subjects in both small and large size spacesuits. When compared to the initial xEMU test series, improved performance was observed across all subjects as the CB moved higher and aligned closer to the system CG.

Pouyan Sabahi↗

Pool boiling critical heat flux studies of accident tolerant fuel cladding materials

Pool boiling experiments have been performed at atmospheric pressure on potential accident tolerant fuel (ATF) cladding materials (Zirlo®, Cr coated Zirlo®, FeCrAl coated Zirlo®, and monolithic SiC) to evaluate the Critical Heat Flux (CHF) points. Corrosion resistant coatings of Cr and FeCrAl alloy were deposited on flat Zirlo® samples using cold spray technology. The as-prepared samples after uniform surface polishing were subjected to autoclave tests at 360 °C water and 18.6 MPa for 360 h to simulate prototypic corrosion of the ATF cladding materials in LWR normal operation. Surface characteristics potentially influencing CHF such as surface morphology, roughness, static contact angle, and surface chemistry were characterized using a suite of characterization methods including scanning electron microscopy, 3D optical profilometry, optical contact angle measurements, and x-ray photoelectron spectroscopy (XPS). Thermo-physical properties of the samples such as density, thermal conductivity, and heat capacity were measured by differential scanning calorimetry and laser flash thermal diffusivity measurement. FeCrAl coatings showed CHF values comparable to bare Zirlo® samples, while slightly lower CHF values were observed for Cr coated samples and bulk SiC flats (produced by chemical vapor deposition, CVD). As-deposited Cr coatings showed 67% higher CHF than the as-polished Cr coatings due to its higher surface roughness level. The autoclave testing for the prepared samples generally increased the CHF except for the surface polished Cr coatings. Similar CHF values of bare Zirlo®, FeCrAl coating, and CVD SiC samples were observed after autoclave test but there were negligible change CHF of Cr coatings. XPS studies indicated that the formation or deposition of a few monolayers of hydrophobic carbonaceous species on surface can affect CHF values. The trends in CHF data are discussed in terms of evolution of the surface characteristics of the ATF materials.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Revitalizing the Space Shuttle's Thermal Protection System with Reverse Engineering and 3D Vision Technology

The Space Shuttle is protected by a Thermal Protection System (TPS) made of tens of thousands of individually shaped heat protection tile. With every flight, tiles are damaged on take-off and return to earth. After each mission, the heat tiles must be fixed or replaced depending on the level of damage. As part of the return to flight mission, the TPS requirements are more stringent, leading to a significant increase in heat tile replacements. The replacement operation requires scanning tile cavities, and in some cases the actual tiles. The 3D scan data is used to reverse engineer each tile into a precise CAD model, which in turn, is exported to a CAM system for the manufacture of the heat protection tile. Scanning is performed while other activities are going on in the shuttle processing facility. Many technicians work simultaneously on the space shuttle structure, which results in structural movements and vibrations. This paper will cover a portable, ultra-fast data acquisition approach used to scan surfaces in this unstable environment.

Wilson, Brad↗

Revitalizing the Space Shuttle's Thermal Protection System with Reverse Engineering and 3D Vision Technology

The Space Shuttle is protected by a Thermal Protection System (TPS) made of tens of thousands of individually shaped heat protection tile. With every flight, tiles are damaged on take-off and return to earth. After each mission, the heat tiles must be fixed or replaced depending on the level of damage. As part of the return to flight mission, the TPS requirements are more stringent, leading to a significant increase in heat tile replacements. The replacement operation requires scanning tile cavities, and in some cases the actual tiles. The 3D scan data is used to reverse engineer each tile into a precise CAD model, which in turn, is exported to a CAM system for the manufacture of the heat protection tile. Scanning is performed while other activities are going on in the shuttle processing facility. Many technicians work simultaneously on the space shuttle structure, which results in structural movements and vibrations. This paper will cover a portable, ultra-fast data acquisition approach used to scan surfaces in this unstable environment.

Wilson, Brad↗

Micropillar compression technique applied to micron-scale mudstone elasto-plastic deformation.

Mudstone mechanical testing is often limited by poor core recovery and sample size, preservation and preparation issues, which can lead to sampling bias, damage, and time-dependent effects. A micropillar compression technique, originally developed by Uchic et al. 2004, here is applied to elasto-plastic deformation of small volumes of mudstone, in the range of cubic microns. This study examines behavior of the Gothic shale, the basal unit of the Ismay zone of the Pennsylvanian Paradox Formation and potential shale gas play in southeastern Utah, USA. Precision manufacture of micropillars 5 microns in diameter and 10 microns in length are prepared using an ion-milling method. Characterization of samples is carried out using: dual focused ion - scanning electron beam imaging of nano-scaled pores and distribution of matrix clay and quartz, as well as pore-filling organics; laser scanning confocal (LSCM) 3D imaging of natural fractures; and gas permeability, among other techniques. Compression testing of micropillars under load control is performed using two different nanoindenter techniques. Deformation of 0.5 cm in diameter by 1 cm in length cores is carried out and visualized by a microscope loading stage and laser scanning confocal microscopy. Axisymmetric multistage compression testing and multi-stress path testing is carried out using 2.54 cm plugs. Discussion of results addresses size of representative elementary volumes applicable to continuum-scale mudstone deformation, anisotropy, and size-scale plasticity effects. Other issues include fabrication-induced damage, alignment, and influence of substrate.

03 NATURAL GAS↗

SU-E-T-424: Feasibility of 3D Printed Radiological Equivalent Customizable Tissue Like Materials

Purpose: To investigate the feasibility of 3D printing CT# specific radiological equivalent tissue like materials. Methods: A desktop 3D printer was utilized to create a series of 3 cm x 3 cm x 2 cm PLA plastic blocks of varying fill densities. The fill pattern was selected to be hexagonal (Figure 1). A series of blocks was filled with paraffin and compared to a series filled with air. The blocks were evaluated with a “GE Lightspeed” 16 slice CT scanner and average CT# of the centers of the materials was determined. The attenuation properties of the subsequent blocks were also evaluated through their isocentric irradiation via “TrueBeam” accelerator under six beam energies. Blocks were placed upon plastic-water slabs of 4 cm in thickness assuring electronic equilibrium and data was collected via Sun Nuclear “Edge” diode detector. Relative changes in dose were compared with those predicted by Varian “Eclipse” TPS. Results: The CT# of 3D printed blocks was found to be a controllable variable. The fill material was able to narrow the range of variability in each sample. The attenuation of the block tracked with the density of the total fill structure. Assigned CT values in the TPS were seen to fall within an expected range predicted by the CT scans of the 3D printed blocks. Conclusion: We have demonstrated that it is possible to 3D print materials of varying tissue equivalencies, and that these materials have radiological properties that are customizable and predictable.

60 APPLIED LIFE SCIENCES↗

The effect of amorphous selenium detector thickness on dual-energy digital breast imaging

Purpose: Contrast enhanced (CE) imaging techniques for both planar digital mammography (DM) and three-dimensional (3D) digital breast tomosynthesis (DBT) applications requires x-ray photon energies higher than the k-edge of iodine (33.2 keV). As a result, x-ray tube potentials much higher (>40 kVp) than those typical for screening mammography must be utilized. Amorphous selenium (a-Se) based direct conversion flat-panel imagers (FPI) have been widely used in DM and DBT imaging systems. The a-Se layer is typically 200 μm thick with quantum detective efficiency (QDE) >87% for x-ray energies below 26 keV. However, QDE decreases substantially above this energy. To improve the object detectability of either CE-DM or CE-DBT, it may be advantageous to increase the thickness (d{sub Se}) of the a-Se layer. Increasing the d{sub Se} will improve the detective quantum efficiency (DQE) at the higher energies used in CE imaging. However, because most DBT systems are designed with partially isocentric geometries, where the gantry moves about a stationary detector, the oblique entry of x-rays will introduce additional blur to the system. The present investigation quantifies the effect of a-Se thickness on imaging performance for both CE-DM and CE-DBT, discussing the effects of improving photon absorption and blurring from oblique entry of x-rays. Methods: In this paper, a cascaded linear system model (CLSM) was used to investigate the effect of d{sub Se} on the imaging performance (i.e., MTF, NPS, and DQE) of FPI in CE-DM and CE-DBT. The results from the model are used to calculate the ideal observer signal-to-noise ratio, d′, which is used as a figure-of-merit to determine the total effect of increasing d{sub Se} for CE-DM and CE-DBT. Results: The results of the CLSM show that increasing d{sub Se} causes a substantial increase in QDE at the high energies used in CE-DM. However, at the oblique projection angles used in DBT, the increased length of penetration through a-Se introduces additional image blur. The reduced MTF and DQE at high spatial frequencies lead to reduced two-dimensional d′. These losses in projection image resolution may subsequently result in a decrease in the 3D d′, but the degree of which is largely dependent on the DBT reconstruction algorithm. For a filtered backprojection (FBP) algorithm with spectral apodization and slice-thickness filters, which dominate the blur for reconstructed images at oblique angles, the effect of oblique entry of x-rays on 3D d′ is minimal. Thus, increasing d{sub Se} results in an improvement in d′ for both CE-DM and CE-DBT with typical FBP reconstruction parameters. Conclusions: Increased d{sub Se} improves CE breast imaging performance by increasing QDE of detectors at higher energies, e.g., 49 kVp. Although there is additional blur in the oblique angled projections of a DBT scan, the overall 3D d′ for DBT is not degraded because the dominant source blur at these angles results from the reconstruction filters of the employed FBP algorithm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Topographic Quintet: Comparing Five Methods for Measuring Ultra-High Resolution Topography

We compare different methods for collecting ultra-high resolution topography data within an analog planetary, human landing site scale area. Our aim is to investigate the cost and benefits of different 3D terrain mapping techniques, their associated data collection methods, and how their different specifications (e.g., range, spatial resolution, scanning-time, mobility, operating constraints, GPS-Denied operation, etc.) might be applied to landing-site characterization and mission operations. We compare 3D terrain data collected during a field campaign in November 2021 from an outcrop at Kilbourne Hole in southern New Mexico using different Light Detection and Ranging (LiDAR) sensors on the ground and stereo-derived 3D data from framing cameras mounted on small uncrewed aerial systems (sUAS).Our foci for this experiment are ground-based, surveying, and autonomous vehicle-type 3D scanning sensors that might be used for planetary surface exploration from landed assets (e.g., lander, rover, astronaut-mounted sensors, decent imaging, hoppers, or drones).[e.g. 1]This test is not meant to benchmark these scanners against one another, nor provide a recommendation for a specific make or model. Rather, our goal is to quantify time, effort, resolution, and operational trade-offs that are important for selecting a topographic instrument/methodology for a given scope of terrain characterization. Our results indicate that each technique is capable of exceptional quality terrain characterization for planetary exploration and scientific inquiry, but we hypothesize the appropriate technique is highly dependent on the scope of operational specifications and science requirements.

P Whelley↗

SU-F-BRD-11: A Virtual Simulator Designed for Collision Prevention in Proton Therapy

Purpose: In proton therapy, collisions between patient and nozzle potentially occur in attaining minimal air gap due to the large nozzle structure. Thus, we developed software predicting the collisions of the nozzle and patient by simulating treatments. Methods: 3D modeling of a gantry inner-floor, nozzle and robotic-couch was done by using the SolidWorks based on the manufacturer’s machine data. To obtain patient body information, a 3D-scanner was utilized to scan a patient right before CT scanning. From the acquired images, a 3D-image of the patient’s body contour was reconstructed. The accuracy of the image was confirmed against the CT image for a humanoid phantom. The machine components and the virtual patient were combined on the treatment-room coordinate system, resulting in a virtual simulator. The simulator simulated the motion of its components such as rotation and translation of gantry, nozzle and couch, in real scale. Collision, if any, was examined both in static mode and dynamic mode. The static mode checks only at fixed positions of the machine’s components while dynamic mode examines while one component is in motion. Collision was notified if any voxel of two components, for example a nozzle and a patient or couch, overlapped when calculating volume locations. The event and collision point are visualized and colliding volumes are reported. Results: All components were successfully assembled and the motions could be accurately controlled. The 3D-shape of a phantom agreed with CT images within a deviation of 2 mm. Collision situations can be simulated within minutes and the results are displayed and reported. Conclusion: The developed software will be useful in improving patient safety and clinical efficiency for proton therapy. This work was supported by the National Research Foundation of Korea funded by Ministry of Science, ICT & Future Planning (2012M3A9B6055201, 2013M2A2A7043507), and Samsung Medical Center grant (GFO1130081)

60 APPLIED LIFE SCIENCES↗

Electron tomography imaging methods with diffraction contrast for materials research

Transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM) enable the visualization of three-dimensional (3D) microstructures ranging from atomic to micrometer scales using 3D reconstruction techniques based on computed tomography algorithms. This 3D microscopy method is called electron tomography (ET) and has been utilized in the fields of materials science and engineering for more than two decades. Although atomic resolution is one of the current topics in ET research, the development and deployment of intermediate-resolution (non-atomic-resolution) ET imaging methods have garnered considerable attention from researchers. This research trend is probably not irrelevant due to the fact that the spatial resolution and functionality of 3D imaging methods of scanning electron microscopy (SEM) and X-ray microscopy have come to overlap with those of ET. In other words, there may be multiple ways to carry out 3D visualization using different microscopy methods for nanometer-scale objects in materials. From the above standpoint, this review paper aims to (i) describe the current status and issues of intermediate-resolution ET with regard to enhancing the effectiveness of TEM/STEM imaging and (ii) discuss promising applications of state-of-the-art intermediate-resolution ET for materials research with a particular focus on diffraction contrast ET for crystalline microstructures (superlattice domains and dislocations) including a demonstration of in situ dislocation tomography.

36 MATERIALS SCIENCE↗

Wood-reinforced composites by stereolithography with the stress whitening behavior

In this study, poplar wood flour at various concentrations (1–10 wt%) is incorporated into a methacrylate-based resin via solution blending to fabricate wood-reinforced composites using stereolithography apparatus (SLA) 3D printing. Differential scanning calorimetry (DSC) along with Fourier transform infrared spectroscopy (FTIR) analysis shows the presence of a small amount of residual monomer in the printed samples. For the printed composites, the glass transition temperature (T g ) from dynamic mechanical analysis (DMA) decreases as more wood flour is incorporated, which indicates an increase in free volume occupied by polymer chains. The tensile strength is improved up to 17.3% from 21.1 MPa (no wood flour) to 24.7 MPa (1.0 wt% wood flour). The highest Young’s modulus reaches 323.8 MPa (2.0 wt% wood flour), which is 1.9-fold of that of the sample without wood flour. Moreover, the composites show “stress whitening” with the addition of wood flour during the uniaxial drawing. Morphology analysis of the tested samples show that the formation of microcraze and microvoids likely causing the stress whitening. This is the first study that demonstrates wood flour can be utilized in SLA 3D printed wood plastic composites (WPC) which can reinforce the printed products with a modest loading amount.

36 MATERIALS SCIENCE↗

TU-PIS-Exhibit Hall-01: CT Dose Optimization Technologies II

Partners in Solutions is an exciting new program in which AAPM partners with our vendors to present practical “hands-on” information about the equipment and software systems that we use in our clinics. The imaging topic this year is CT scanner dose optimization capabilities. Note that the sessions are being held in a special purpose room built on the Exhibit Hall Floor, to encourage further interaction with the vendors. Siemens‘ Commitment to the Right Dose in Computed Tomography Presentation Time: 11:15 - 11:45 AM Providing sustainable clinical results at highest patient safety: This is the challenge in medical imaging. Especially for Computed Tomography this means applying not simply the lowest, but the right dose for sound diagnostic imaging. Consequently, Siemens is committed to deliver the right dose in CT. In order to reduce radiation to the right dose, the first step is to provide the right dose technology. Through decades of research and development in CT imaging, Siemens CT has constantly introduced new ideas leading to a comprehensive portfolio of unique CARE technologies to deliver the right dose. For example automated kV adjustment based on patient size and the clinical question with CARE kV and three generations of iterative reconstruction. Based on the right dose technology, the next step is to actually scan at the right dose. For this, it is key to know the right dose targets for every examination. Siemens continuously involves CT experts to push developments further and outline how users can best adapt their procedures to the right dose. For users to know whether they met the right dose targets, it is therefore important to understand and monitor the actual absolute dose values. All scanners are delivered with defined default protocols which automatically use the available right dose technologies. Finally, to deliver the right dose not just in singular cases, but ideally to patients everywhere, organizations need then to manage dose across their institutions. Here Siemens offers the right dose management tools for administrations to analyze and document dose, to train their clinical staff and to continuously optimize the application of the right dose in clinical routine. Siemens CT is not only adhering to the ALARA principle, but is inspired by it. With CARE Right Siemens show their commitment to the right dose in CT. Toshiba Aquilion CT Dose Management Tools Presentation Time: 11:45 - 12:15 PM A practical review of Toshiba’s CT dose management technologies from the physicist’s perspective. This presentation will include an overview of Toshiba’s CT dose reduction technologies and dose safeguards. Content will include answers to frequently asked questions relating to dose management, dose tracking, CTDI measurement, ACR accreditation, ACR QC, and protocol review on Toshiba CT systems. Specific topics will include the following: Toshiba’s mechanism of tube current modulation; Exposure record format and interpretation of the values; Dose reporting and dose safeguard tools; Use of AIDR 3D iterative reconstruction; The configuration of task specific image quality target and its integration with AIDR 3D; Tips for scanning the ACR phantom with wide beam geometry; Measuring CTDI for wide beam geometry; Discussion of daily QC procedures and specifications; Tips for annual QC evaluation; Protocol management tools.

60 APPLIED LIFE SCIENCES↗

New Tools for Automating Arcjet Sample Recession Tracking and Analysis

Arcjet Computer Vision (arcjetCV) has been significantly upgraded to enhance accuracy and performance in tracking material recession and shock-material standoff in test videos. These improvements include integrating new machine learning models, developing a specialized edge detection class, and incorporating a more comprehensive training dataset. These upgrades have refined the software’s ability to automate time-resolved recession tracking, making it more precise and reliable for analyzing complex physical processes. In parallel, a new tool called STARscan (Spatial Targeting and Alignment Rig for Scanning) is being developed to capture detailed 3D surface data before and after testing. By comparing these pre- and post-test scans with arcjetCV’s automated video analysis results, users can achieve a more comprehensive assessment of material recession. This method enables cross-validation of results, improving confidence in the analysis of tested materials. The expanded capabilities of arcjetCV have been successfully demonstrated on videos from various facilities, including the NASA Ames arcjets, UIUC’s PlasmatronX, and the VKI Plasmatron. It has been adopted as a new standard for in-situ recession tracking by the Mars Sample Return Project and Orion. ArcjetCV’s improved efficiency and accuracy are critical for reducing testing uncertainties and validating heatshield material performance under extreme conditions. The software’s user-friendly graphical interface ensures ease of use, enabling seamless processing and precise analysis of arcjet videos, providing deeper insights into material behavior in hypersonic environments. ArcjetCV is now available on both PyPI and Conda, allowing easy installation via "pip install arcjetCV" or through the Conda package manager, ensuring broad accessibility and streamlined deployment for users across various platforms.

Ablation↗

Corrosion Behavior of Q235 Steel Exposed in Deepwater of South China Sea

For the first time, the corrosion behavior of Q235 steel in 1200, 2000 and 3000 m deepwater of South China Sea for 0.5 year was reported in this study. The corrosion morphology and corrosion products properties were investigated using different techniques, such as 3D optical microscope, scanning electron microscope, x-ray diffraction analyzer and electrochemical impedance spectroscopy. The main environmental factors influencing the corrosion rate of Q235 in deep sea were discussed by applying gray relational analysis. The results indicated that uniform thinning occurred after exposure. A large number of tiny pits were distributed under the corrosion products with a two-layer structure. The corrosion rate and average pitting depth of samples exposed at 2000 m were lower than those exposed at 1200 and 3000 m, and the main environmental factors determining the variation of corrosion rate at different depths were temperature and dissolved oxygen concentration. Hydrostatic pressure had slight effect on the corrosion rate of Q235 steel, but promoted the formation of a more uniform corrosion morphology.

36 MATERIALS SCIENCE↗

Temporally continuous thermofluidic–thermomechanical modeling framework for metal additive manufacturing

Additive manufacturing (AM) is known to generate large magnitudes of residual stresses (RS) within builds due to steep and localized thermal gradients. In the current state of commercial AM technology, manufacturers generally perform heat treatments in effort to reduce the generated RS and its detrimental effects on part distortion and in-service failure. Computational models that effectively simulate the deposition process can provide valuable insights to improve RS distributions. Accordingly, it is common to employ Computational fluid dynamics (CFD) models or finite element (FE) models. While CFD can predict geometric and thermal-fluid behavior, it cannot predict the structural response (e.g., stress–strain) behavior. On the other hand, an FE model can predict mechanical behavior, but it lacks the ability to predict geometric and fluid behavior. Thus, an effectively integrated thermofluidic–thermomechanical modeling framework that exploits the benefits of both techniques while avoiding their respective limitations can offer valuable predictive capability for AM processes. In contrast to previously published efforts, the work herein describes a one-way coupled CFD-FEA framework that abandons major simplifying assumptions, such as geometric steady-state conditions, the absence of material plasticity, and the lack of detailed RS evolution/accumulation during deposition, as well as insufficient validation of results. Here, the presented framework is demonstrated for a directed energy deposition (DED) process, and experiments are performed to validate the predicted geometry and RS profile. Both single- and double-layer stainless steel 316L builds are considered. Geometric data is acquired via 3D optical surface scans and X-ray micro-computed tomography, and residual stress is measured using neutron diffraction (ND). Comparisons between the simulations and measurements reveal that the described CFD-FEA framework is effective in capturing the coupled thermomechanical and thermofluidic behaviors of the DED process. The methodology presented is extensible to other metal AM processes, including power bed fusion and wire-feed-based AM.

42 ENGINEERING↗

Damage morphology study of high cycle fatigued as-cast Mg–3.0Nd–0.2Zn–Zr (wt.%) alloy

Laser scanning confocal microscopy (LSCM) and Electron back-scattered diffraction (EBSD) were applied to the study of surface morphology variation of as-cast Mg–3.0Nd–0.2Zn–Zr (NZ30K) (wt.%) alloy under tension-compression fatigue test at room temperature. Two kinds of typical damage morphologies were observed in fatigued NZ30K alloy: One was parallel lines on basal planes led by the cumulation of basal slips, called persistent slip markings (PSMs), and the other was lens shaped, thicker and in less density, led by the formation of twinning. The surface fatigue damage morphology evolution was analyzed in a statistical way. The influences of stress amplitude and grain orientation on fatigue deformation mechanisms were discussed and the non-uniform deformation among grains and the PSMs, within twinning were described quantitatively. - Highlights: • Fatigue morphology evolution was studied by Laser Scanning Confocal Microscopy. • 3D morphology of persistent slip markings and twins was characterized. • Non-uniform deformation among grains, the PSMs and twins were quantified. • Initiations of fatigue crack were clearly investigated.

36 MATERIALS SCIENCE↗