Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D Visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

PNNL-Predictive-Phenomics/ProCaliper

ProCaliper is a Python library that curates, organizes, and computes protein structure features in a way that easily interfaces with user-provided experimental data. It extracts or computes protein binding site, active site, charge, pLDDT (order/disorder), acid dissociation, protonation, solvent accessible surface area, disulfide bond distance, and protein secondary structure data using precomputed protein structures and publicly available databases. It provides a unified API for integrating additional residue-level data and for visualizing residue features in 3D.

Rozum, Jordan [Pacific Northwest National Lab]↗

Ultrasonic Bat Deterrent Technology

The project objective was to advance the development and testing of a near commercial bat-deterrent system with a goal to increase the current GE deterrent system effectiveness to over 50% with broad species applicability. Additionally, the research supported by this program has provided insights into bat behavior and ultrasonic deterrent design that had not previously been explored. Prior research and development had demonstrated the effectiveness of a commercial-grade, air-powered, ultrasonic bat deterrent to be between 30-50% depending upon the species of bat. However, the previous research provided limited insight into the behavioral responses of bats in the presence of ultrasonic deterrent sound fields that could be utilized to improve effectiveness. A unique bat flight room was utilized to observe the behavioral characteristics of bats in the presence of ultrasonic sound fields. Behavioral testing in the bat flight facility demonstrated that ultrasonic sounds similar to those produced by the GE deterrent influenced the activities and behaviors, primarily those associated with foraging, of the species exposed. The study also indicated that continuous and pulsing ultrasonic signals had a similar effect on the bats, and confirmed that as ultrasonic sounds attenuate, their influence on the bats’ activities and behavior decreases. Ground testing at Wolf Ridge Wind, LLC and Shawnee National Forest assessed both continuous and pulsing deterrent signals emitted from the GE deterrent system and further enhanced the behavioral understanding of bats in the presence of the deterrent. With these data and observations, the existing 4-nozzle continuous, or steady, emission ultrasonic system was redesigned to a 6-nozzle system that could emit a pulsing signal covering a larger air space around a turbine. Twelve GE 1.6-100 turbines were outfitted with the deterrent system and a formal three-month field study was performed using daily carcass searches beneath the 12 turbines. Additionally, a unique 3D bat flight path visualization system was utilized to monitor for and identify any changes in bat activity caused by the operation of the deterrent system. Both the carcass search and flight path visualization data indicated that the pulsed deterrent system was effective, but not more effective, than the steady system tested in prior years. However, an unanticipated byproduct of the pulsing system was the emission of intermittent water vapor from the deterrent devices due to the air compression process that powered the devices. This water vapor may have altered the ultrasonic signal and obscured the results in an unknown way. While a qualitative analysis of the effect of the water vapor on the deterrent signal had indicated there was not dramatic change in the expected ultrasonic signal, it was not possible to conclusively determine if the pulse signal would have been more effective in the absence of the water vapor. A mid-season installation of a desiccant system was performed and the dataset divided into two groups to account for the change. Prior to the system change, the deterrent was not effective (-23%, P = 0.8617, α = 0.05) at reducing eastern red bat fatalities and effective (38%, P = 0.0169, α = 0.05) for the non-eastern red bat species, combined. After the installation of the desiccant system, the pulsed deterrent system showed similar results, although not statistically significant, with a point estimates of 23% (P = 0.2924, α = 0.05) observed for eastern red bats and 54% (P = 0.0926, α = 0.05) for the other combined bat species.

17 WIND ENERGY↗

Raptor

Raptor is an efficient Python-based tool for predicting the formation and morphology of stochastic lack of fusion defects in metal AM processes. A major obstacle for the qualification and certification of additively manufactured parts in critical applications continues to be performance variability caused in part by porosity-related defects. High-fidelity process models that could predict these defect features are currently too computationally expensive for component-level analysis. To address this, Raptor employs a high-performance geometric method to model the dynamic melt pool rather than relying on computationally intensive thermal fluid dynamics. This allows Raptor to rapidly identify regions of unmelted material that correspond to lack of fusion pores. The efficiency of this approach significantly reduces the time and resources needed for generating 3D defect predictions, which enables users to conduct large-scale parameter studies and evaluate how process variations affect part quality. The framework offers operational flexibility; users can execute simulations through a simple command line interface or integrate core functions as a library within larger computational workflows. Simulation outputs include 3D porosity maps for visualization and tools for quantitative morphological analysis. These results are suitable for direct comparison with experimental characterization data from methods such as X-ray computed tomography and can be used for statistical process optimization.

Subraveti, Vamsi [Vanderbilt Univ., Nashville, TN ↗

RCSB Protein Data Bank: visualizing groups of experimentally determined PDB structures alongside computed structure models of proteins

Recent advances in Artificial Intelligence and Machine Learning (e.g., AlphaFold, RosettaFold, and ESMFold) enable prediction of three-dimensional (3D) protein structures from amino acid sequences alone at accuracies comparable to lower-resolution experimental methods. These tools have been employed to predict structures across entire proteomes and the results of large-scale metagenomic sequence studies, yielding an exponential increase in available biomolecular 3D structural information. Given the enormous volume of this newly computed biostructure data, there is an urgent need for robust tools to manage, search, cluster, and visualize large collections of structures. Equally important is the capability to efficiently summarize and visualize metadata, biological/biochemical annotations, and structural features, particularly when working with vast numbers of protein structures of both experimental origin from the Protein Data Bank (PDB) and computationally-predicted models. Moreover, researchers require advanced visualization techniques that support interactive exploration of multiple sequences and structural alignments. This paper introduces a suite of tools provided on the RCSB PDB research-focused web portal RCSB. org, tailor-made for efficient management, search, organization, and visualization of this burgeoning corpus of 3D macromolecular structure data.

3D visualization↗

Moving beyond the Solvent-Tip Approximation to Determine Site-Specific Variations of Interfacial Water Structure through 3D Force Microscopy

Although interfacial solution structure impacts environmental, biological, and technological phenomena, including colloidal stability, protein assembly, heterogeneous nucleation, and water desalination, its molecular details remain poorly understood. Here, we visualize the three-dimensional (3D) hydration structure at the boehmite(010)-water interface using fast force mapping (FFM). Using a self-consistent scheme to decouple long-range tip-sample interactions from short-range solvation forces, we obtain the solution structure with lattice resolution. The results are benchmarked against molecular dynamics simulations that explicitly include the effects of the tip with different levels of approximation and systematically account for tip size, chemistry, and confinement effects. We find four laterally structured water layers within 1 nm of the surface, with the highest water densities at sites adjacent to hydroxyl groups. The key features beyond the first two layers can only be predicted using a full-scale simulation of the boehmite-water-silica system. Our findings further reveal a complex relationship between site-specific chemistry, water density, and long-range particle interactions; and present important advances toward quantitative data interpretation in 3D FFM.

36 MATERIALS SCIENCE↗

How does C-VIEW image quality compare with conventional 2D FFDM?

Purpose: The FDA approved the use of digital breast tomosynthesis (DBT) in 2011 as an adjunct to 2D full field digital mammography (FFDM) with the constraint that all DBT acquisitions must be paired with a 2D image to assure adequate interpretative information is provided. Recently manufacturers have developed methods to provide a synthesized 2D image generated from the DBT data with the hope of sparing patients the radiation exposure from the FFDM acquisition. While this much needed alternative effectively reduces the total radiation burden, differences in image quality must also be considered. The goal of this study was to compare the intrinsic image quality of synthesized 2D C-VIEW and 2D FFDM images in terms of resolution, contrast, and noise. Methods: Two phantoms were utilized in this study: the American College of Radiology mammography accreditation phantom (ACR phantom) and a novel 3D printed anthropomorphic breast phantom. Both phantoms were imaged using a Hologic Selenia Dimensions 3D system. Analysis of the ACR phantom includes both visual inspection and objective automated analysis using in-house software. Analysis of the 3D anthropomorphic phantom includes visual assessment of resolution and Fourier analysis of the noise. Results: Using ACR-defined scoring criteria for the ACR phantom, the FFDM images scored statistically higher than C-VIEW according to both the average observer and automated scores. In addition, between 50% and 70% of C-VIEW images failed to meet the nominal minimum ACR accreditation requirements—primarily due to fiber breaks. Software analysis demonstrated that C-VIEW provided enhanced visualization of medium and large microcalcification objects; however, the benefits diminished for smaller high contrast objects and all low contrast objects. Visual analysis of the anthropomorphic phantom showed a measureable loss of resolution in the C-VIEW image (11 lp/mm FFDM, 5 lp/mm C-VIEW) and loss in detection of small microcalcification objects. Spectral analysis of the anthropomorphic phantom showed higher total noise magnitude in the FFDM image compared with C-VIEW. Whereas the FFDM image contained approximately white noise texture, the C-VIEW image exhibited marked noise reduction at midfrequency and high frequency with far less noise suppression at low frequencies resulting in a mottled noise appearance. Conclusions: Their analysis demonstrates many instances where the C-VIEW image quality differs from FFDM. Compared to FFDM, C-VIEW offers a better depiction of objects of certain size and contrast, but provides poorer overall resolution and noise properties. Based on these findings, the utilization of C-VIEW images in the clinical setting requires careful consideration, especially if considering the discontinuation of FFDM imaging. Not explicitly explored in this study is how the combination of DBT + C-VIEW performs relative to DBT + FFDM or FFDM alone.

60 APPLIED LIFE SCIENCES↗

Direct Visualization of Magnetic Correlations in Frustrated Spinel ZnFe 2 O 4

Magnetic materials with the spinel structure (A 2+ B 3+ 2 O 4 ) form the core of numerous magnetic devices, and ZnFe 2 O 4 constitutes a peculiar example where the nature of the magnetism is still unresolved. Susceptibility measurements revealed a cusp around T c = 13 K resembling an antiferromagnetic transition, despite the positive Curie–Weiss temperature determined to be Θ CW = 102.8(1) K. Bifurcation of field-cooled and zero-field-cooled data below T c in conjunction with a frequency dependence of the peak position and a non-zero imaginary component below T c shows it is in fact associated with a spin-glass transition. Highly structured magnetic diffuse neutron scattering from single crystals develops between 50 K and 25 K revealing the presence of magnetic disorder which is correlated in nature. Here, the 3D-mΔPDF method is used to visualize the local magnetic ordering preferences, and ferromagnetic nearest-neighbor and antiferromagnetic third nearest-neighbor correlations are shown to be dominant. Their temperature dependence is extraordinary with some flipping in sign and a strongly varying correlation length. The correlations can be explained by orbital interaction mechanisms for the magnetic pathways and a preferred spin cluster. This study demonstrates the power of the 3D-mΔPDF method in visualizing complex quantum phenomena thereby providing a way to obtain an atomic-scale understanding of magnetic frustration.

36 MATERIALS SCIENCE↗

BioSig3D: High Content Screening of Three-Dimensional Cell Culture Models

BioSig3D is a computational platform for high-content screening of three-dimensional (3D) cell culture models that are imaged in full 3D volume. It provides an end-to-end solution for designing high content screening assays, based on colony organization that is derived from segmentation of nuclei in each colony. BioSig3D also enables visualization of raw and processed 3D volumetric data for quality control, and integrates advanced bioinformatics analysis. The system consists of multiple computational and annotation modules that are coupled together with a strong use of controlled vocabularies to reduce ambiguities between different users. It is a web-based system that allows users to: design an experiment by defining experimental variables, upload a large set of volumetric images into the system, analyze and visualize the dataset, and either display computed indices as a heatmap, or phenotypic subtypes for heterogeneity analysis, or download computed indices for statistical analysis or integrative biology. BioSig3D has been used to profile baseline colony formations with two experiments: (i) morphogenesis of a panel of human mammary epithelial cell lines (HMEC), and (ii) heterogeneity in colony formation using an immortalized non-transformed cell line. These experiments reveal intrinsic growth properties of well-characterized cell lines that are routinely used for biological studies. BioSig3D is being released with seed datasets and video-based documentation.

Science & Technology - Other Topics↗

Visualizing the Internal Nanocrystallinity of Calcite Due to Nonclassical Crystallization by 3D Coherent X–Ray Diffraction Imaging

The internal crystallinity of calcite is investigated for samples synthesized using two approaches: precipitation from solution and the ammonium carbonate diffusion method. Scanning electron microscopy (SEM) analyses reveal that the calcite products precipitated using both approaches have a well–defined rhombohedron shape, consistent with the euhedral crystal habit of the mineral. The internal structure of these calcite crystals is characterized using Bragg coherent diffraction imaging (BCDI) to determine the 3D electron density and the atomic displacement field. BCDI reconstructions for crystals synthesized using the ammonium carbonate diffusion approach have the expected euhedral shape, with internal strain fields and few internal defects. In contrast, the crystals synthesized by precipitation from solution have very complex external shapes and defective internal structures, presenting null electron density regions and pronounced displacement field distributions. These heterogeneities are interpreted as multiple crystalline domains, created by a nonclassical crystallization mechanism, where smaller nanoparticles coalescence into the final euhedral particles. The combined use of SEM, X–ray diffraction (XRD), and BCDI allows for structurally differentiating calcite crystals grown with different approaches, opening new opportunities to understand how grain boundaries and internal defects alter calcite reactivity.

36 MATERIALS SCIENCE↗

RCSB Protein Data Bank: improved annotation, search and visualization of membrane protein structures archived in the PDB

Abstract Motivation Membrane proteins are encoded by approximately one fifth of human genes but account for more than half of all US FDA approved drug targets. Thanks to new technological advances, the number of membrane proteins archived in the PDB is growing rapidly. However, automatic identification of membrane proteins or inference of membrane location is not a trivial task. Results We present recent improvements to the RCSB Protein Data Bank web portal (RCSB PDB, rcsb.org) that provide a wealth of new membrane protein annotations integrated from four external resources: OPM, PDBTM, MemProtMD and mpstruc. We have substantially enhanced the presentation of data on membrane proteins. The number of membrane proteins with annotations available on rcsb.org was increased by ∼80%. Users can search for these annotations, explore corresponding tree hierarchies, display membrane segments at the 1D amino acid sequence level, and visualize the predicted location of the membrane layer in 3D. Availability and implementation Annotations, search, tree data and visualization are available at our rcsb.org web portal. Membrane visualization is supported by the open-source Mol* viewer (molstar.org and github.com/molstar/molstar). Supplementary information Supplementary data are available at Bioinformatics online.

59 BASIC BIOLOGICAL SCIENCES↗

Retrieving spin textures on curved magnetic thin films with full-field soft X-ray microscopies

X-ray tomography is a well-established technique to characterize 3D structures in material sciences and biology; its magnetic analogue—magnetic X-ray tomography—is yet to be developed. We demonstrate the visualization and reconstruction of magnetic domain structures in a 3D curved magnetic thin films with tubular shape by means of full-field soft X-ray microscopies. In the 3D arrangement of the magnetization is retrieved from a set of 2D projections by analysing the evolution of the magnetic contrast with varying projection angle. By using reconstruction algorithms to analyse the angular evolution of 2D projections provides quantitative information about domain patterns and magnetic coupling phenomena between windings of azimuthally and radially magnetized tubular objects. In conclusion, the present approach represents a first milestone towards visualizing magnetization textures of 3D curved thin films with virtually arbitrary shape.

36 MATERIALS SCIENCE↗

TU-F-BRF-04: Registration of 3D Transesophageal Echocardiography and X-Ray Fluoroscopy Using An Inverse Geometry X-Ray System

Purpose: To develop a method for the fusion of 3D echocardiography and Scanning-Beam Digital X-ray (SBDX) fluoroscopy to assist with catheter device and soft tissue visualization during interventional procedures. Methods: SBDX is a technology for low-dose inverse geometry x-ray fluoroscopy that performs digital tomosynthesis at multiple planes in real time. In this study, transesophageal echocardiography (TEE) images were fused with SBDX images by estimating the 3D position and orientation (the “pose”) of the TEE probe within the x-ray coordinate system and then spatially transforming the TEE image data to match this pose. An initial pose estimate was obtained through tomosynthesis-based 3D localization of points along the probe perimeter. Position and angle estimates were then iteratively refined by comparing simulated projections of a 3D probe model against SBDX x-ray images. Algorithm performance was quantified by imaging a TEE probe in different known orientations and locations within the x-ray field (0-30 degree tilt angle, up to 50 mm translation). Fused 3D TEE/SBDX imaging was demonstrated by imaging a tissue-mimicking polyvinyl alcohol cylindrical cavity as a catheter was navigated along the cavity axis. Results: Detected changes in probe tilt angle agreed with the known changes to within 1.2 degrees. For a 50 mm translation along the source-detector axis, the detected translation was 50.3 mm. Errors for in-plane translations ranged from 0.1 to 0.9 mm. In a fused 3D TEE/SBDX display, the catheter device was well visualized and coincident with the device shadow in the TEE images. The TEE images portrayed phantom boundaries that were not evident under x-ray. Conclusion: Registration of soft tissue anatomy derived from TEE imaging and device imaging from SBDX x-ray fluoroscopy is feasible. The simultaneous 3D visualization of these two modalities may be useful in interventional procedures involving the navigation of devices to soft tissue anatomy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3D camera assisted fully automated calibration of scanning laser Doppler vibrometers

Scanning laser Doppler vibrometers (LDV) are used to measure full-field vibration shapes of products and structures. In most commercially available scanning laser Doppler vibrometer systems the user manually draws a grid of measurement locations on a 2D camera image of the product. The determination of the correct physical measurement locations can be a time consuming and diffcult task. In this paper we present a new methodology for product testing and quality control that integrates 3D imaging techniques with vibration measurements. This procedure allows to test prototypes in a shorter period because physical measurements locations will be located automatically. The proposed methodology uses a 3D time-of-flight camera to measure the location and orientation of the test-object. The 3D image of the time-of-flight camera is then matched with the 3D-CAD model of the object in which measurement locations are pre-defined. A time of flight camera operates strictly in the near infrared spectrum. To improve the signal to noise ratio in the time-of-flight measurement, a time-of-flight camera uses a band filter. As a result of this filter, the laser spot of most laser vibrometers is invisible in the time-of-flight image. Therefore a 2D RGB-camera is used to find the laser-spot of the vibrometer. The laser spot is matched to the 3D image obtained by the time-of-flight camera. Next an automatic calibration procedure is used to aim the laser at the (pre)defined locations. Another benefit from this methodology is that it incorporates automatic mapping between a CAD model and the vibration measurements. This mapping can be used to visualize measurements directly on a 3D CAD model. Secondly the orientation of the CAD model is known with respect to the laser beam. This information can be used to find the direction of the measured vibration relatively to the surface of the object. With this direction, the vibration measurements can be compared more precisely with numerical experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

From 2D to 4D: a containerized workflow and browser to explore dynamic chromatin architecture

Background Characterizing the physical organization of the genome is essential for understanding long-range gene regulation, chromatin compartmentalization, and epigenetic accessibility. Hi-C experiments generate two-dimensional (2D) genome-wide contact maps of chromatin interactions by capturing the spatial proximity between genomic loci, which reveal interaction frequencies but lack the spatial resolution needed to interpret the three-dimensional (3D) genome structure(s). Emerging evidence suggests that epigenetic regulation is closely linked to 3D genome architecture, and that structural changes over time (4D) drive key biological processes in development, disease, and environmental response. Thus, integrating 3D structure with functional data is critical for a more complete understanding of genome regulation. Previous work, most notably the 4DHiC chromosome modeling framework, has shown that physical multi-dimensional modeling approaches rooted in polymer physics and molecular dynamics can resolve these structures at biologically meaningful resolutions by integrating temporal Hi-C data with physical constraints to uncover dynamic chromosome reorganization. Thus, molecular dynamics simulations, constrained by Hi-C contact matrices, can resolve fine-scale structural changes and reveal functionally significant transitions in chromatin conformation. Results Herein, we present the 4D Genome Browser Workflow (4DGBWorkflow) and the 4D Genome Browser (4DGB). The algorithm is based on the 4DHiC method, and the containerized tool is an end-to-end workflow that can transform, filter, and view 4D epigenomics and chromatin datasets, allowing non-specialists to apply three-dimensional modeling principles to diverse datasets and experimental conditions. The software executes on a laptop running macOS, Linux or Windows. From input Hi-C files (.hic), the 4DGBWorkflow produces 3D reconstructions of chromosomes, integrates the reconstruction with track data (e.g., epigenetic marks, transcriptome profiles), and provides comparative visualization of the results in a single workflow. Conclusions The 4DGBWorkflow and 4D Genome Browser are open-source tools for comparative analysis and visualization of 4D chromosome datasets, including chromatin architecture and epigenomic signals. Automatic integration of Hi-C data with molecular dynamics democratizes the construction of time resolved 3D genome structures, simplifying complex simulations and data integration schemes.

3D Genome Browser↗

Visualization of Jet Impingement and Ignition in a Piston-Cylinder Chamber

The transportation sector accounts for almost a third of the United States' energy consumption. We are developing predictive simulations of the complex in-cylinder processes of internal combustion engines to improve performance and decrease pollutant emissions. We provide a first look at the jet impingement and ignition inside a piston-cylinder chamber using volume rendering. Through the visualization, we constructed a complete 3D picture of the jet impingement on the piston-bowl walls leading to the formation of pockets of auto-ignition of the fuel-air mixture. These auto-ignition pockets subsequently lead to flame stabilization, releasing the chemical energy for conversion to useful work. A detailed physical picture of flame stabilization, as provided by the visualization techniques presented in this study, help in the design of next-generation internal combustion engines.

91 SC - Advanced Scientific Computing Reseach (ASC↗

Falcon: Visual analysis of large, irregularly sampled, and multivariate time series data in additive manufacturing

Flexible visual analysis of long, high-resolution, and irregularly sampled time series data from multiple sensor streams is a challenge in several domains. In the field of additive manufacturing, this capability is critical for realizing the full potential of large-scale 3D printers. Here, we propose a visual analytics approach that helps additive manufacturing researchers acquire a deep understanding of patterns in log and imagery data collected by 3D printers. Our specific goals include discovering patterns related to defects and system performance issues, optimizing build configurations to avoid defects, and increasing production efficiency. We introduce Falcon, a new visual analytics system that allows users to interactively explore large, time-oriented data sets from multiple linked perspectives. Falcon provides overviews, detailed views, and unique segmented time series visualizations, all with adjustable scale options. To illustrate the effectiveness of Falcon at providing thorough and efficient knowledge discovery, we present a practical case study involving experts in additive manufacturing and data from a large-scale 3D printer. The techniques described are applicable to the analysis of any quantitative time series, though the focus of this paper is on additive manufacturing.

97 MATHEMATICS AND COMPUTING↗

3D microstructure reconstruction of casting aluminum alloy based on serial block-face scanning electron microscopy

In this work, the inner microstructure of aluminum-silicon casting alloy was experimentally investigated to reveal the spatial morphology and phase distribution. Its industrial use is as a light-weight structural material. As a powerful three-dimensional (3D) imaging tool at the nano-scale, the serial block-face scanning electron microscopy (SBFSEM) was employed to investigate the specimens. After being 3D reconstructed, the images were visualized to identify preference for several specific intermetallics by quantitative analysis. It was found that these phases have certain relationships in spatial distribution and differences in spatial shapes. In conclusion, the spatial distribution of cracks was studied to understand their propagation and growth.

3D microstructure reconstruction↗

SynopFrame: Multiscale time-dependent visual abstraction framework for analyzing DNA nanotechnology simulations

We present an open-source framework, SynopFrame, that allows DNA nanotechnology (DNA-nano) experts to analyze and understand molecular dynamics simulation trajectories of their designs. We use a multiscale multi-dimensional abstraction space, connect the representations to a projected conformational space plot of the structure’s temporal sequence, and thus enable experts to analyze the dynamics of their structural designs and, specifically, failure cases of the assembly. In addition, our time-dependent abstraction representation allows the biologists, for the first time in a smooth and structurally clear way, to identify and observe temporal transitions of a DNA-nano design from one configuration to another, and to highlight important periods of the simulation for further analysis. We realize SynopFrame as a dashboard of the different synchronized 3D spatial and 2D schematic visual representations, with a color overlay to show essential properties such as the status of hydrogen bonds. The linking of the spatial, schematic, and abstract views ensures that users can effectively analyze the high-frequency motion. We also categorize the status of the hydrogen bonds into a new format to allow us to color-encode it and overlay it on the representations. To demonstrate the utility of SynopFrame, we describe example usage scenarios and report user feedback.

Abstraction space↗