Search NASA⌕ Search

SEARCH · Search NASA

Results for “AIR FLOW - COMPRESSIBILITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Numerical Modeling of Atmospheric Rime Ice Accretion on an Airfoil Using an Eulerian Approach

This paper presents an approach to numerically simulate the inherently unsteady rime ice accretion problem on a two-dimensional airfoil and elucidate the associated variations under different icing conditions. The airflow field and the water impingement on the airfoil are obtained based on an Eulerian two-phase model. A dynamic mesh strategy is employed to unsteadily account for the changes in the ice profile and its impact on the air and droplet flow by continuously reconstructing the computational grid at each time-step through smoothing and layering mechanisms. All main icing modules including the airflow field, droplet trajectory, icing thickness profile, and mesh management are fully coupled within the same computational framework without resorting to any external tools. Classical icing theory is employed to model the rime ice roughness, and it is assumed that the ice accretes in a direction normal to the airfoil surface. The governing Reynolds-averaged Navier–Stokes (RANS) conservation equations along with the energy and continuity equations are solved to produce the velocity and temperature fields. A convective film heat transfer coefficient is computed based on the surface heat flux and a recovery temperature which takes into account the dissipative heat release in the boundary layer in the vicinity of the airfoil surface. With the implemented strategy and calculating the convective heat transfer coefficient, the water film thickness is also calculated along with the ice shape. Furthermore, the model is validated by comparing the local collection efficiency distribution and ice shape with experimental data, and the results show that the implemented approach provides acceptable predictions of ice accretion profiles and rates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PFLOTRAN

PFLOTRAN is a GNU LGPL licensed code that simulates single phase water and multiphase (air, co2, water) flow, energy transport, geochemical reaction and biological reaction in the earth's subsurface environment. The problem may be discretized on structured and unstructured grids. The code is designed to run in parallel on supercomputers and leverages the open source PETSc library for solvers and data structures and open source HDF5 for binary file I/O. See www.pflotran.org and/or doc-dev.pflotran.org for further information. SAND2020-12161 M Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Hammond, Glenn↗

VorLap

SAND2025-10210O VorLap is a vortex-induced vibration overlap prediction tool for static structures, such as parked wind turbines and marine turbines encountering fluid flow (water or air movement around them) that may induce vortex-induced vibration. This tool uses precomputed frequency domain data for specific cross-sectional shapes or a generalized shedding model, along with geometric data and structural natural frequency data, to identify areas and conditions where vortex-induced vibration may occur. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Moore, Kevin [Sandia National Lab. (SNL-CA), Liver↗

Assessment of an E10 gasoline surrogate: Qualitative and quantitative comparisons of in-cylinder spray morphology

A minimum-component gasoline fuel surrogate that captures both chemical and physical behaviors of a full-distillate fuel is needed for high-fidelity CFD simulations. This study evaluates gasoline spray characteristics in a direct-injection spark-ignition engine under motored operation. Two fuels are compared; PACE-20, which is a 9-component surrogate formulation of RD5-87, is compared with its target fuel RD5-87, which is a full-boiling range research grade E10 gasoline. The spray morphologies of both fuels are recorded for a centrally-located direct-injection 8-hole spray subject to intake air cross-flow during the early part of the intake stroke. High-speed imaging recorded scattered light of the side and axial projections of the liquid spray. Quantitative metrics were developed and employed to facilitate comparison of spray morphologies as well as to identify the transition in spray morphology due to flash boiling. This paper builds on a previous study of RD5-87 where coolant temperature (20°C–100°C), in-cylinder pressure (40–110 kPa), engine speed (650–1950 rpm), and injection pressure (60–180 bar) were systematically changed to span operating conditions with and without flash boiling. Images of the PACE-20 morphology are selected for a sub-set of operating conditions from the previous study where distinctive morphology changes occurred. Visual inspection of the images and quantitative metrics demonstrate that the PACE-20 spray morphology is equivalent to that of the RD5-87 in most cases. The exception was for changes in the ambient-gas pressure where the flash-boiling transition occurred at ∼5 kPa higher in-cylinder pressure for PACE-20. Three empirical metrics, Merging Index, Asymmetry, and Flash Index are proposed here and they were found to be useful both as quantitative comparisons of the fuel morphologies, and for identifying the transition in spray morphology due to flash boiling.

Kim, Namho↗

The Influence of Soil Properties on Sea-Breeze Circulations in the Southeast U.S.

Sea-breeze circulations (SBCs) are common weather phenomena at and near coastal regions. They form because of a thermal gradient between the land surface at the coast and the sea surface. In a mid-day regime, a “thermal low” generated at the warm coast will lead to rising air motion, creating a wind shift coming from the sea near the surface displacing the coastal air. A “return flow” moving back towards the sea is generated by upper-level divergence because of the rising motion from the thermal low. SBCs propagate and serve as a method of urban pollutant dispersion in the Los Angeles region of California and are constrained to the coast due to the topography of surrounding mountains serving as a boundary for further inland propagation. Within the northeast U.S. SBCs are seen in the warm season but tend to remain coastally bound due to Coriolis distortion over long distances. Within the southeast U.S. (SEUS), the paradigmatic example of SBCs occurs over the Florida peninsula, where thunderstorms form on a nearly daily occurrence due to the convergence of SBCs from the east and west sides of the peninsula. However, there are further examples of sea-breezes in the SEUS that warrant study. Within the region bordering the SEUS and the Mid-Atlantic, just east of the southern Appalachian Mountains, warm-season SBCs form at the coast of Georgia and the Carolinas. Relatively flat topography ~150-200km inland allows for mostly unimpeded inland SBC propagation. Through visual analysis, Viner et al. catalogued several SBCs that propagated as far inland as the Central Savannah River Area surrounding Augusta, Georgia. Wermter et al. found that while the land-sea thermal gradient at the coast can influence coastal SBC genesis, the inland-coastal thermal gradient over the land is the primary influencer on the speed and depth of inland propagation of SBCs in this region. Additionally, soil moisture itself is a known correlative factor to sea-breeze formation, as it influences the soil temperature and the thermal gradient needed for SBC genesis and inland penetration. Physick determined that higher latent heat fluxes associated with wetter soil dampen the land-sea thermal gradient and suppress the formation of a SBC. Physick determined that higher latent heat fluxes associated with wetter soil dampen the land-sea thermal gradient and suppress the formation of a SBC. Conversely, drier soil enhances the thermal gradient and promotes SBC formation. However, while there is an inverse relationship between soil moisture and SBCs, higher soil moisture can actually promote more convective rainfall following a SBC if it does not significantly impact the thermal gradient. While the relationship between soil moisture and SBC formation has been conceptually explored and modeled numerically, there is a research gap in observed connections. The Soil Moisture Active Passive (SMAP) satellite mission has been operational since 2015 and has been used to create high-resolution re-analytical Level 4 (L4) datasets of soil moisture and soil temperature at different soil depths: the surface (0-5cm) and rootzone (0-1m). The surface soil temperature effectively acts as the “skin temperature” of the surface at these levels, and a spatial map of the land-sea as well as the coastal-inland thermal gradients can be represented. SMAP data are also assimilated in some atmospheric models such at the High Resolution Rapid Refresh (HRRR) mesoscale model. We propose leveraging the use of SMAP products to fill in spatial gaps left by weather and mesonet stations within the SEUS region, as well as assessing the effectiveness of utilizing SMAP products towards SBC forecasting in both deterministic and machine learning (ML) models.

58 GEOSCIENCES↗

Temperature Distribution Within an Ignition Kernel Initiated by a Laser-Induced Plasma

The sizes of, and temperature distributions within, ignition kernels initiated by a Q-switched neodymium-doped yttrium aluminum garnet laser-induced plasma in an unconfined lean premixed hydrogen-air upward jet flow are investigated. The experiments involved a range of jet velocities and a range of deposited laser energies at a fixed height above the exit along the axis of a burner. The growth of, and the temperature distributions within, the ignition kernels, as affected by the size and the energy distribution of the laser-induced plasma, are monitored with an infrared camera. The initial ignition kernels’ areas are larger with higher laser pulse energies and remain unchanged up to [Formula: see text] and then increase by factors of up to 3 at [Formula: see text]. The change in the kernel area caused by the jet velocities is less than 1.5%. An increase of the bulk velocity by 190% decreases the ignition kernel temperature by 6%. This reduction in the ignition kernel temperatures is because of an increase in energy losses by a factor of 2 and decreases in heat releases by 2% at [Formula: see text] and by 11% at [Formula: see text]. The present contributions are: measurements of and insights into temperature distributions and kernel development rates during the laser-induced plasma ignition process at different deposited energies and flow velocities.

Engineering↗

The Effect of Spark-Plug Heat Dispersal Range and Exhaust Valve Opening Timing on Cold-Start Emissions and Cycle-to-Cycle Variability

The partnership for advancing combustion engines (PACE) is a US Department of Energy consortium involving multiple national laboratories and includes a goal of addressing key efficiency and emission barriers in light-duty engines fueled with a market-representative E10 gasoline. A major pillar of the initiative is the generation of detailed experimental data and modeling capabilities to understand and predict cold-start behavior. Cold-start, as defined by the time between first engine crank and three-way catalyst light-off, is responsible for a large percentage of NOx, unburned hydrocarbon and particulate matter emissions in light-duty engines. Minimizing emissions during cold-start is a trade-off between achieving faster light-off of the three-way catalyst and engine out emissions during that period. In this study, gaseous and soot emissions were measured at a distance representative of the three-way catalyst position downstream of the engine at a 2 bar net indicated mean effective pressure (NIMEP) steady-state operating condition representative of cold-start. The test matrix included sweeps of ignition timing 15 degrees-before to 10 degrees-after top dead center firing (TDCf) across three different spark-plug heat dispersal ranges (HR). Additionally, the effect of varying exhaust valve opening (EVO) timing on combustion stability and emissions was also studied. Results show that the spark plug HR affects the coefficient of variation (COV) of NIMEP under all cold-start conditions, while the impact on emissions was found to be minimal. At very retarded spark timings, colder spark plugs required higher air and fuel flow to maintain the desired 2bar NIMEP load, but the fraction of fuel energy going into the exhaust was found to be similar for all spark plugs. Finally, retarding exhaust valve timings showed a simultaneous reduction in emissions while increasing the fraction of fuel energy being fed into the exhaust. However, engine COV was also observed to increase with retarded exhaust timings.

42 ENGINEERING↗

Extreme wind shear events in US offshore wind energy areas and the role of induced stratification

As the offshore wind industry emerges on the US East Coast, a comprehensive understanding of the wind resource – particularly extreme events – is vital to the industry's success. Such understanding has been hindered by a lack of publicly available wind profile observations in offshore wind energy areas. However, the New York State Energy Research and Development Authority recently funded the deployment of two floating lidars within two current lease areas off the coast of New Jersey. These floating lidars provide publicly available wind speed data from 20 to 200 m height with a 20 m vertical resolution. In this study, we leverage a year of these lidar data to quantify and characterize the frequent occurrence of high-wind-shear and low-level-jet events, both of which will have a considerable impact on turbine operation. In designing a detection algorithm for these events, we find that the typical, non-dimensional power-law-based wind shear exponent is insufficient to identify many of these extreme, high-wind-speed events. Rather, we find that the simple vertical gradient of wind speed better captures the events. Based on this detection method, we find that almost 100 independent events occur throughout the year with mean wind speed at 100 m height and wind speed gradient of 16 m s -1 and 0.05 s -1 , respectively. The events have strong seasonal variability, with the highest number of events in summer and the lowest in winter. A detailed analysis reveals that these events are enabled by an induced stable stratification when warmer air from the south flows over the colder mid-Atlantic waters, leading to a positive air–sea temperature difference.

17 WIND ENERGY↗

Cooling methods for medium voltage drive systems

In one aspect, a medium voltage power converter includes a cabinet having: a power cube bay to house a plurality of power cubes, each of the plurality of power cubes adapted within a corresponding enclosure and comprising a low frequency front end stage, a DC link and a high frequency back end stage, the plurality of power cubes to couple to a high speed machine; and a plurality of first barriers adapted to isolate and direct a first flow of cooling air through one of the plurality of power cubes; and a transformer bay having at least one transformer to couple between a utility connection and the plurality of power cubes, the transformer bay including a plurality of cooling fans to cool the at least one transformer.

Ledezma, Enrique↗

MOSAiC-Colorado State University Ice Spectrometer

This data set contains atmospheric ice nucleating particle (INP) measurements, using Colorado State University&rsquo;s (CSU) Ice Spectrometer (IS), of filter collections taken at the U.S. DOE ARM AMF2 site onboard the R/V Polarstern P-deck during the Multidisciplinary Drifting Observatory for the Study of Arctic Climate (MOSAiC) field campaign. Samples were collected from October 27, 2019 to September 24, 2020. A filter sampler was mounted approximately 15 m above ground level on a railing in proximity to (and approximately 3 m below) the Aerosol Observation System (AOS) inlet. Single-use filter units open to the atmosphere were pre-cleaned and pre-loaded with 47-mm diameter Nuclepore polycarbonate (0.2 &micro;m pore-diameter) filters. Filters were typically drawn for a three-day period, with an average volume of air filtered of 87,000 standard liters. Total volumes were calculated through recorded daily flow rates using a mass flow meter (TSI). After collection, filters were stored and transported frozen until analysis using CSU&rsquo;s IS instrument (McCluskey et al., 2018). Aerosol particles were first re-suspended in 8 mL of 0.1 &micro;m-filtered deionized (DI) water. Aliquots of each suspension, and corresponding 11-fold dilutions, were dispensed into polymerase chain reaction (PCR) trays and placed into the aluminum blocks of the IS. Samples were cooled at approximately 0.33 &deg;C min -1 and freezing detected optically with corresponding temperatures recorded. Cumulative INP concentrations were determined through calculating the number of INPs per mL of suspension (Vali, 1971) and converting to concentration per standard L of air by accounting for the proportion of liquid used and volume of air collected. All samples were corrected for the number of INPs on the average of four field blanks (cleaned, handled, transported, and analyzed in the same way without air flow). Two-tailed, 95% confidence intervals for binomial sampling are provided (Agresti and Coull, 1998). Select samples were also heat treated (95 &deg;C for 20 min) to denature and deactivate biological INPs present and digested in 10% H 2 O 2 at 95 &deg;C under UV-B for 20 min to remove any organic carbon INPs. Agresti, A, and BA Coull. 1998. "Approximate is better than &ldquo;exact&rdquo; for interval estimation of binomial proportions." American Statistics 52: 119&ndash;126. https://doi.org/10.2307/2685469 McCluskey, CS, J Ovadnevaite, M Rinaldi, J Atkinson, F Belosi, D Ceburnis, &hellip; and PJ DeMott. 2018. "Marine and Terrestrial Organic Ice-Nucleating Particles in Pristine Marine to Continentally Influenced Northeast Atlantic Air Masses." Journal of Geophysical Research: Atmospheres 123 (11): 6196&ndash;6212, https://doi.org/10.1029/2017JD028033 Vali, G. 1971. "Quantitative Evaluation of Experimental Results and the Heterogeneous Freezing Nucleation of Supercooled Liquids." Journal of the Atmospheric Sciences 28: 402-209. https://doi.org/10.1175/1520-0469(1971)028<0402:QEOERA>2.0.CO;2

54 ENVIRONMENTAL SCIENCES↗

Promoting CO 2 Release from CO 3 2- -Containing Solvents during Water Electrolysis for Direct Air Capture

The pH swings from water electrolysis are leveraged to condition OH – -based facile CO 2 capture solvents using an electrochemical flow cell for direct air capture (DAC). Besides demonstrating the DAC using a membrane contactor, promoting CO 2 release from a CO 3 2– solution at the anode is specifically studied by adjusting the volumetric flow rate, anode chamber volume, residence time, and K 2 CO 3 concentration. Through case-by-case comparisons coupled with modeled results, increasing current, reducing volumetric flow rate, and/or reducing CO 3 2– concentration are the effective methods to promote CO 2 release from a CO 3 2– -containing solvent, whereas enlarging the anode chamber volume poses a minor effect. Moreover, the discrepancies between the experimental and modeled results may be caused by H + crossover rather than K + transport through the Nafion membrane during water electrolysis based upon the total alkalinity measurements for the K 2 CO 3 solutions gleaned from the anode. Here, it is believed that such results will provide guidance to design and operate an electrochemical flow cell for electrochemistry-assisted DAC and point source CO 2 capture.

20 FOSSIL-FUELED POWER PLANTS↗

A multiphase flow model of water droplets dielectrophoretic-induced air dehumidification phenomena

Air humidity in indoor spaces plays a critical role in human comfort and health. Dehumidification systems are used for building humidity controls, but they can take significant energy consumption, especially in geographic locations with high outdoor humidity and warm climates. Consequently, there is a growing demand for innovative dehumidification processes that consume minimal energy. Dielectrophoretic air dehumidification represents one such promising approach. However, it has not garnered significant attention due to the absence of engineering models and simulation tools capable of evaluating its performance and limitations at large-scale airflows. A new numerical multiphase CFD model, which is also experimentally validated, is developed in a customized Reacting Foam solver based on OpenFOAM® version 9. The newly developed model seeks to decrease substantial energy consumption and lower costs by leveraging the dielectrophoretic phenomenon to regulate moisture levels in the air. The solver integrates a hybrid Eulerian-Lagrangian framework to track the droplet's trajectory and growth rate while solving the continuum equations for the moist air. An electrospray produces electrically charged droplets, which grow during their in-flight trajectories as water vapor condenses onto their surfaces. The role of electrostatic forces in promoting vapor condensation within a high-gradient electrical field is investigated, and the dielectrophoretic vapor nucleation process on charged water droplets is discussed. The CFD model was validated against results from the literature and from proof-of-concept experiments conducted by the authors, which showed a 2 % air dehumidification with a single electrospray and airflow rate of 5 cubic feet per minute. The simulation results indicated that augmenting the number of electrically charged spray droplets increased the dehumidification of the air to 25 %. The initial mean droplet diameter, the orientation of the injector and relative humidity significantly influence the assessment of dehumidification. As a result, scaling up this approach to larger airflow volumes is identified as a potential future research direction.

42 ENGINEERING↗

Resource Characterization to Estimate Potential for Electricity Co-Production at Blackburn Oil Field, Nevada

The U.S. Department of Energy estimates that an annual average of 25 billion barrels of hot water are produced from oil and gas wells within the United States. The thermal energy available in the co-produced water stream is usually discarded, as the produced waters are considered an inconvenience by the operators and are disposed of using injection wells. However, utilizing organic Rankine cycle (ORC) generators, a vast amount of thermal energy can be captured and converted into electricity (albeit at relatively low efficiency due to the low temperatures). The National Renewable Energy Laboratory (NREL), in collaboration with Transitional Energy and Grant Canyon Oil & Gas, evaluated the feasibility of geothermal co-production of electricity by utilizing existing oil wells in Blackburn oil field in Nevada. The once prolific Blackburn oil field is located in Pine Valley, approximately 45 miles east-southeast of Elko, Nevada. Currently, the wells targeting the highly fractured Devonian Nevada dolomite reservoir are operating at a water cut ratio of more than 99%, with individual fluid (oil and water) production rates reaching 7.4 L/s (4,021 BBL/day). Analysis of publicly available data showed that the combination of the suitable wells' maximum historical production rates reached 22.90 L/s. The production from these wells occurs naturally and the wells are choked (and even shut down) by the operator to mitigate excessive water production, indicating a strong reservoir recharge and future opportunity to increase the water production for geothermal electricity generation. The main goal of this study was to evaluate the productivity of the existing wells, the performance of the reservoir, the surface network, and the operational constraints in order to achieve 1 MWe of electricity production from the field's water production. Utilizing the GEOPHIRES tool, we have determined that a twofold to threefold increase in the total fluid production, compared to the historical production under artificial restraint (choke), is required to reach a 1-MWe net target output for a low-temperature ORC system with air-cooled condensers. Lower flow rates would be required when utilizing water-based condensers instead of air-cooled condensers. However, that would require a constant supply of cold water, which may be challenging given the arid environment of the project site.

Blackburn↗

Accelerated Aging Humidity Chamber for Nuclear Grade HEPA Filter Media

A unique accelerated aging humidity chamber for simulating the natural aging process of nuclear grade high efficiency particulate air (HEPA) filter media is being designed, implemented, and tested. The nuclear industry currently lacks information regarding the shelf life and service life of HEPA filter media. The Department of Energy recommends disposing of HEPA filters 10 years after the manufacture date for filters operated under dry conditions. Studies have shown the tensile strength and water repellency of HEPA filter media diminish with age. The chamber's principal function is to sustain an elevated relative humidity condition for an extended duration specified by the Arrhenius aging model. To accomplish this, various design parameters were established: (1) consistently achieve uniform humidity conditions within the chamber to equally expose media sheets, (2) ensure the chamber is sufficiently sealed to mitigate the uncontrolled infiltration of air, (3) confidently secure the media sheets to avert the introduction of unnecessary stressing/creasing, (4) fabricate the chamber from clear polycarbonate material to allow inspection of the media sheets, (5) provide a safe and ergonomic design for personnel, (6) ensure the chamber design is replicable and relatively easy to fabricate/assemble. A humidity source, fan, PID controller, humidity and temperature transmitters, and data loggers are required for proper operation and control of the chamber. The humidity source must accommodate target values up to 95% relative humidity throughout the chamber. The three humidity and temperature transmitters are strategically spaced throughout the chamber to ensure uniform conditions. The 10 cubic feet per minute (CFM) fan selected intends to accomplish the desired air change rate inside the chamber of approximately 20 air changes per hour (ACH). The 2 plenums on the upper and lower portions of the chamber utilize a perforated design to uniformly distribute air, promote air mixing, and control the air velocity entering the chamber. Industrial blueprint hanging clamps are being retrofitted to be seated within the chamber drawers and firmly secure the nuclear grade filter media. The aged media will be evaluated using autopsy methodology, and the results obtained intend to help clarify the useful life of nuclear grade HEPA filters. Nuclear grade high efficiency particulate air (HEPA) filters are defined as disposable, extended-media, dry-type filters with a rigid casing enclosing the full depth of the pleats and have a minimum particle removal efficiency of 99.97%. [1] - HEPA filters are constantly exposed to stressors and subsequently have been shown to degrade as the filter ages. Properties such as tensile strength and water repellency, along with others, are negatively impacted. [2] - Due to the scarcity of naturally aged HEPA filters available, it is crucial to develop accelerated aging methods which effectively mimic the natural degradation effects. - After accelerated aging, the filters are subject to testing in the Axial Flow Large Scale Test Stand (ALSTS) and other analysis techniques such as the same qualification tests performed directly after being manufactured. - Quality data is necessary for future decisions regarding the lifetime of nuclear grade HEPA filters. - The objective is to develop a prototype accelerated aging humidity chamber for nuclear grade HEPA filter media. The chamber should expose the media to commonly occurring stressors to expedite the degradation process caused by aging. PID yields reliable and reproducible results: - CFD model correlates well with actual performance; - Further analysis is needed to complete characterization; - Future work for the chamber is still to be completed. The data shown in Figure 5 and Table 1 indicate the system is functioning as designed. As can be determined from the system response evaluation in Table 1, the PID controller is yielding reliable and reproducible results at each set point. As the set point increases, the time constant and 20% settling time increase accordingly. From the results in Table 1, it stands to reason that the CFD model correlates well with the actual performance of the system. Each system response parameter for the 90%RH* CFD model is slightly lower than the parameters collected from the physical model tested at an equivalent set point. This is to be expected considering the inlet in the CFD model is a constant supply of water vapor, whereas the physical model uses a PID controller to monitor the amount of water vapor needed and reacts accordingly. More analysis is still to be done on the prototype chamber. A pressure test will be conducted in order to determine the hourly leak rate of the chamber. This test will involve constant air flow into the chamber until the desired pressure is reached. A uniformity test will also be conducted in order to ensure each filter medium is being exposed to equivalent relative humidity levels. This test will involve an array of humidity meters strategically oriented inside the chamber to record any possible gradients. Future work for the chamber includes dehumidification abilities, tests while fully loaded with filters, and temperature control. Once completed, the autopsy team at Institute of Clean Energy Technology will conduct necessary accelerated aging studies as needed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of an anti-clogging perforated plate atomizer for a zero liquid discharge humidification-dehumidification desalination system

An anti-clogging perforated plate atomizer is designed for high temperature and salinity applications in a novel solar-powered zero liquid discharge humidification-dehumidification desalination system (US Patent Application US62882953). Herein this paper presents a detailed discussion on its design, and operation. Experiments are performed on seven atomizers to study the effect of design, and operating parameters on spray cone angle, and average droplet diameter. Spray cone angle remains constant with change in air mass flux, and increases with increasing orifice diameter, and manifold diameter. It also increases initially with water mass flow rate, and manifold height, before attaining a constant value. Average droplet diameter increases with increasing water mass flow rate, and decreasing air mass flux, orifice diameter, and manifold diameter. Further, anti-clogging performance of the atomizer is tested with hypersaline water of 100,000 ppm total dissolved solid (NaCl) at elevated temperatures such as air at 175 °C and saline water at 45 °C. Results show no clogging for 2–13 h of operation. Near-complete suppression of atomizer clogging makes our new additively-manufactured perforated plate atomizer an ideal fit for high salinity, and zero liquid discharge humidification-dehumidification desalination systems. Additionally, its open-surface design allows additional surface modifications to further reduce clogging, and enhance self-cleaning characteristics.

47 OTHER INSTRUMENTATION↗

Large-Eddy Simulation Study of Flow and Combustion Dynamics in a Full-Scale Hydrogen–Air Rotating Detonation Combustor-Stator Integrated System

In the present work, a first-of-its-kind three-dimensional (3D) large-eddy simulation (LES) study is conducted to numerically investigate the combustion dynamics as well as aero-thermal phenomena in a full-scale nonpremixed hydrogen–air rotating detonation engine (RDE) (with a diverging-shaped lower-end wall), when integrated with nozzle guide vanes (NGV) acting as the turbine stator. The wall-modeled LES framework incorporates hydrogen–air detailed chemical kinetics and adaptive mesh refinement (AMR). A comparative analysis is carried out for two operating conditions with different fuel/air mass flow rates but global equivalence ratio of unity, and considering RDE configurations without and with stator. The LES model is validated against available experimental data for the low mass flux condition with respect to detonation wave speed/height, wave dynamics, and axial static pressure distribution. Numerical results indicate significant deflagrative combustion occurring in the fill region near the inner wall due to formation of recirculation zones in the injection near-field driven by the backward facing step. The leading detonation wave is found to be trailed by an azimuthal reflected-shock combustion (ARSC) wave, consistent with experimental observations, which consumes unburned vitiated reactants that leak through the main detonation wave. The main detonation wave characteristics, such as detonation wave speed/height and combustion efficiency, do not change appreciably with the presence of NGV. A novel combustion diagnostic technique based on chemical explosive mode analysis (CEMA) is employed to quantify the fraction of heat release occurring in the detonative mode versus deflagrative mode for the simulated conditions. The exit flow is found to be nearly fully subsonic and supersonic for the low and high mass flux conditions, respectively. Further analysis of the exit flow profiles shows that the presence of NGV renders the flow more axial and significantly impacts the exit Mach number and total pressure, while the total temperature shows negligible change. In addition, the low mass flux operating point, despite exhibiting more deflagrative losses within the combustor, yields overall lower pressure drop from plenum to exhaust, which is mainly attributed to lower pressure drop across the injectors. Lastly, the rotating detonation engine-nozzle guide vanes (RDE-NGV) configuration exhibits higher total pressure loss compared to rotating detonation engine (RDE) without stator across both the mass flux conditions. In conclusion, this study extends the state-of-the-art in numerical modeling of pressure gain combustion (PGC) systems by demonstrating high-fidelity 3D reacting LES of full-scale RDE-NGV systems relevant to RDE-turbine integration for stationary power generation.

Combustion↗

Analysis of ducted fuel injection at high-pressure transcritical conditions using large-eddy simulations

Ducted fuel injection (DFI) is a proposed fuel injection concept for achieving substantial reductions in emissions. In this concept, the fuel is injected through a coannular duct, resulting in increased fuel-air mixing and minimized formation of soot and other unwanted combustion products. Apart from comprehensive experimental investigations on DFI, so far computational studies have been limited to single-point Reynolds-averaged Navier Stokes simulations. Therefore, the objective of this work is to complement these studies by performing large-eddy simulations using a diffuse-interface method to examine the physical mechanisms and combustion processes of DFI, specifically focusing on the mixing process and the effect of fuel-ducting on combustion and pollutant emissions. To this end, finite-rate chemistry simulations are performed of the DFI configuration corresponding to the Engine Combustion Network Spray A injector at transcritical conditions (n-dodecane fuel, 60 bar pressure and 1000 K temperature chamber conditions). A two-equation soot model is employed for the qualitative analysis of soot emissions. Direct comparisons of averaged and instantaneous flow field results with the Spray A configuration are performed to assess the effect of DFI on the first- and second-stage ignition and soot formation. Compared to the free-spray condition, the results show that the DFI case exhibits a combination of (i) increased mass flow rate and entrained air, (ii) larger pressure drop magnitude and flow velocity, and (iii) a closer-to-stoichiometric mixture composition (both globally and locally), each of which is conjectured to contribute toward reduced soot production.

33 ADVANCED PROPULSION SYSTEMS↗