Search NASA⌕ Search

SEARCH · Search NASA

Results for “Acceleration cavities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Development of a half-meter scale Traveling-Wave (TW) SRF cavity

Traveling-wave technology can push the accelerator field gradient of niobium SRF cavity to 70MV/m or higher beyond the fundamental limit of 50~60MV/m in Standing-Wave regime. The 1st demonstration of TW resonance excitation in a proof-of-principle 3-cell SRF cavity in 2K liquid helium was successfully carried out at Fermilab in collaboration with Euclid Techlabs. In parallel with that, the RF design process of 0.5~1 meter scale TW cavity was begun at Fermilab for advancing TW technologies necessary more for future accelerator-scale one. Considering the physical dimensions of existing SRF facilities (for fabrication, processing, and cryogenic testing) and the lessons learned from the 3-cell, Fermilab has proposed a preliminary RF design of a half-meter scale TW SRF cavity. It consists of a 7-cell structure and a power feedback waveguide (WG) loop with new RF configurations to control TW resonance. Here we report a preliminary RF design, development plans, and activities.

43 PARTICLE ACCELERATORS↗

Extraction of ion beam from laser ion source for direct plasma injection scheme

Laser ion sources are expected to be used in various applications of heavy ion beam technology. The plasma direct injection scheme (DPIS) is a method in which ion beams extracted from a laser ion source are directly injected into a radio frequency quadrupole (RFQ) linear accelerator. In this study, a new shape of the plasma electrode with a concave surface for the DPIS was proposed to inject a converging beam to a cavity of RFQ accelerator. This approach allows the use of a large-diameter extraction electrode, which is not limited by the aperture of the RFQ electrode rods. The DPIS, using the concave surface electrode, was employed to accelerate C 6+ ion beams. The results indicated that both the beam current and the number of ions increased nearly twice with the proposed electrode shape compared to values obtained with the conventional electrode. This enhancement corresponded to the increased extraction area of the beam.

43 PARTICLE ACCELERATORS↗

Nb3Sn Coating of Twin Axis Cavity and Other Complex SRF Cavity Structures

In the field of Accelerator Science, for the low cost and increased quality factor, thin films coated niobium cavities are used in the modern SRF research. Within the potential substances, Nb3Sn has shown higher critical temperature than niobium. Here the tin vapor diffusion method is used as the preferred technique to coat niobium cavities. So far, only elliptical cavities have been coated with Nb3Sn and this technique has not yet been applied to cavities with complex geometries, which are also helpful in the accelerator science field. The Half-wave resonator could provide us data across frequencies of interest for particle accelerators world wide. Similarly the Twin axis cavity proposed for Energy Recovary Linac (ERL) applications could benefit from Nb3Sn coating. But with their advanced geometries, increased area, more number of ports and hard to reach areas, a different coating approach is needed to provide a uniform coating of Nb3Sn. We used twin axis cavity to optimize the coating technique and followed a low temperature annealing to further improvement of the thin film quality by low temperature annealing as a post coating method. With these we could expand the current coating system at JLab to coat complex cavity models

Tiskumara, Jayendrika↗

HIGHLY-EFFICIENT 20-MW L-BAND MULTI-BEAM KLYSTRON

The overall goal of this project was to develop and demonstrate a novel two-stage multi-beam klystron (TS-MBK) for use in accelerator, medical, national security, medical, and environmental cleanup applications. The novelties embodied in the TS-MBK design include use of hollow beams to obtain strong coupling to cavities, and post acceleration after bunching to reduce the beam’s energy spread to allow an exceptional electronic efficiency that we predict can reach 90%. During Phase I of this project, Omega-P R&D refined its conceptual design of the 1.0 GHz TS-MBK, and collector design and cooling requirements for several levels of average power output. If, as was the case, it turned out that estimated costs for fabrication and testing of a full 12-beam TS-MBK prototype would exceed available Phase II funding, our Plan-B would have be adopted. In it, a single-beam version would have been designed and built, with all specifications identical to the 12-beam version, except that the average power level would be reduced by a factor of about 12. This one-beam version would still allow evaluation of the efficacy of our design concept for implementing two stages, including prevention of radiation loss at the HV gap, and for demonstrating the predicted 90% electronic efficiency and the absence of reflected electrons from the collector reaching the cathodes. But the absence of the expected industrial partner in further development of this novel RF source made it impractical for advancing the project into Phase II.

43 PARTICLE ACCELERATORS↗

Development of a Traveling-Wave (TW) SRF cavity

Traveling-wave technology can push the accelerator field gradient of niobium SRF cavity to 70MV/m or higher beyond the fundamental limit of 50~60MV/m in Standing-Wave regime. The 1st demonstration of TW resonance excitation in a proof-of-principle 3-cell SRF cavity in 2K liquid helium was successfully carried out at Fermilab in collaboration with Euclid Techlabs. In parallel with that, to advancing TW technologies necessary more for future accelerator-scale one, Fermilab has proposed a preliminary RF design of a half-meter scale TW SRF cavity by considering the physical dimensions of existing SRF facilities and the lessons learned from the 3-cell,. It consists of a 7-cell structure and a power feedback waveguide (WG) loop with new RF configurations to control TW resonance. Development efforts toward a TW 7-cell has been in progress. Here we report the recent activities and progresses of those.

Furuta, F.↗

Microstructural and Superconducting Radiofrequency Properties of Multilayer Sequentially Sputtered Nb 3 Sn films

Nb 3 Sn is considered as a potential candidate for superconducting radiofrequency cavities for particle acceleration due to its higher transition temperature of 18.3 K and higher superheating field of 400 mT. Nb 3 Sn films can be grown inside the surface of a Nb cavity by sequentially sputtering multiple layers of Nb and Sn thin films followed by annealing at 950 °C for 3 h. We report on the properties of Nb 3 Sn films grown on Nb substrates by magnetron sputtering. The films’ crystal structure, surface morphology, and composition were characterized by X-ray diffraction, scanning electron microscopy, and energy-dispersive X-ray spectroscopy. The films had a polycrystalline Nb 3 Sn structure with a fine-grain surface and an atomic Sn composition of ~23%. The RF surface resistance of the films was measured for different temperatures at 7.4 GHz to understand the feasibility of this method for the SRF application. The RF surface resistance of the films was 5 mΩ at 12 K, which is about 2 orders of magnitude higher than 60 μΩ previously measured in Nb 3 Sn films grown by Sn vapor diffusion. Finally, the sputtered film had a superconducting transition at 17.2 K, which is also lower than 17.9 K observed in Nb 3 Sn film prepared by vapor diffusion.

43 PARTICLE ACCELERATORS↗

RF Frontiers for Particle Physics, the US View

In this talk I provide an update on the RF research for future colliders in the U.S., through the prism of Snowmass and P5 report. During Snowmass, we considered various applications of RF technology to the proposed future colliders and other accelerator- and non-accelerator-based experiments. P5 narrowed down the choices of future machines. The colliders include circular and linear $e^+ e^-$ Higgs factories, and longer-term options such as muon and hadron high energy colliders. I will start with Snowmass and P5 recommendations. As it is impossible to cover all possible RF R&D topics, I will discuss only three critical topics relevant to future colliders: efficiency of RF power sources, cold normal conducting RF, and cavities for ionization channel of muon collider. Progress on SRF accelerating cavities for future colliders will be covered in a separate talk. The choice of topics reflects my preference and in some cases ignorance, which I think is inevitable when one tries to cover such a broad subject.

43 PARTICLE ACCELERATORS↗

Correction of crosstalk effect in the Low Energy RHIC electron Cooler Booster Cavity

we report that the Low Energy Relativistic Heavy Ion Collider (RHIC) electron Cooler (LEReC) is designed to deliver a 1.6 MeV to 2.6 MeV electron beam, with rms dp/p less than 5e-4. The superconducting radiofrequency (SRF) Booster Cavity is the major accelerating component in LEReC. It is a 0.4 cell cavity operating at 2 K, providing a maximum energy gain of 2.2 MeV. It is modified from an experimental Energy Recovery Linac (ERL) photocathode gun, and thus has fundamental power couplers (FPCs), pickup (PU) couplers (field probes) and HOM coupler close to each other on the same side of the cavity. Direct capacitive coupling between the FPC and PU, called the crosstalk effect, combined with microphonic detuning, can induce closed loop voltage fluctuations that exceed the total energy spread requirement of LEReC. The crosstalk effect in this cavity is modelled, simulated, and measured, and a correction method is proposed and demonstrated to suppress the voltage fluctuation so that energy spread requirement can be met.

43 PARTICLE ACCELERATORS↗

Dual-energy electron storage ring

A dual-energy electron storage ring is a novel concept initially proposed to cool hadron beams at high energies. The design consists of two closed rings operating at significantly different energies: the low-energy ring and the high-energy ring. These two rings are connected by an energy recovery linac (ERL) that provides the necessary energy difference. The ERL features superconducting radio-frequency (SRF) cavities that first accelerate the beam from the low energy E L to the high energy E H and then decelerate the beam from E H to E L in the next pass. The different SRF cavities in the ERL section can be adjusted based on the applications. In this paper, we present a possible layout of a dual-energy electron storage ring. The preliminary optics of the ring is designed to optimize chromaticity correction, dynamic aperture, momentum aperture, beam lifetime, radiation damping, and intrabeam scattering effects. The primary focus of this paper is on the stability conditions and beam dynamics studies associated with this storage ring. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Operational Experience of the NML Cryogenic Plant at the FAST Test Facility

The NML cryogenic plant cools two individually cryostated superconducting radio frequency (SRF) capture cavities and one prototype ILC cryomodule with eight SRF cavities. This complex accelerates electrons at 150 MeV for the Integrable Optics Test Accelerator (IOTA) ring, located at the Fermilab Accelerator Science and Technology (FAST) facility. The cryogenic plant is composed of two nitrogen precooled Tevatron satellite refrigerators, two Mycom 2016C compressors, a cryogenic distribution system, a Frick purifier compressor, two charcoal bed adsorber purifiers, and a liquid ring vacuum pump with a roots booster. The SRF cavities are immersed in a 2.0 K liquid helium bath, shielded with a 5 K gaseous helium shield and a liquid nitrogen cooled thermal shield. Since 2019, this R&D accelerator complex has gone through four science runs with an average duration of 12 months. Operational experience for each run, availability metrics, performance data and common outages are presented in this paper.

Wallace, Timothy [Fermilab] (ORCID:000900051589302↗

BEAM ACCELERATION WITH A Nb3Sn CRYOMODULE AT JLAB

We report on the electron beam acceleration experiment with a Nb3Sn cryomodule at Thomas Jefferson National Laboratory (JLAB). Two CEBAF-style 5-cell 1.5 GHz Nb3Sn cavities operated at 4 K, accelerating a 100 nA continuous-wave (CW) electron beam from 200 keV to 4 MeV at JLAB’s Upgraded Injector Test Facility (UITF). The acceleration gradients in each cavity reached 11 MV/m and 7 MV/m, respectively. No field emission was observed. The unloaded quality factors reached 2¿109 at low fields at 4 K.

Geng, R. [Thomas Jefferson National Accelerator Fa↗

Three-Dimensional Reconstruction of Nb 3 Sn Films by Focused Ion Beam Cross Sectional Microscopy

Niobium has been the material of choice for SRF cavities for several decades due to its formability and superconducting properties. The accelerating gradient of niobium cavities is, however, rapidly approaching a theoretical limit. To achieve higher accelerating gradients a new material is needed that can sustain high fields. Nb 3 Sn is a promising competitor with a higher superconducting transition temperature and a higher critical field than pure niobium. However, Nb 3 Sn is very brittle and cannot be formed readily into a cavity. The main method for creating Nb 3 Sn cavities is to form a Nb 3 Sn film into a niobium surface using a tin vapor-diffusion method. This technique creates a microcrystalline Nb 3 Sn thin film on the inner surface of the cavity. Tin depleted regions are known to form in the film during this process. Previous studies have analyzed these regions using transmission electron microscopy on cross-sectional lamellae prepared by focused ion beam/scanning electron microscope (FIB/SEM). This method does not provide any three-dimensional (3-D) information about the distribution of tin-deficient regions. In this study we employ a focused ion beam tomographic technique to analyze the 3-D structure of the film. Electron dispersive X-ray spectroscopy is used to image the tin concentration of the film in 3-D. Tin-deficient regions are discovered close to the surface of the Nb 3 Sn film.

Viklund, E.↗

Development of a compact electron cyclotron resonance accelerator for industrial and security applications

We describe the development of a novel accelerator, an electron Cyclotron Resonance Accelerator (eCRA) [1], to produce high power electron beams and X-ray beams for medical, research, sterilization, and national security applications. The several attractive features of eCRA include: a compact robust room-temperature single-cell RF cavity as the accelerating structure; continuous ampere-level high current output; and production of a self-rastering electron beam, thus eliminating the need for a separate beam scanner. Progress on the eCRA development, including numerical simulation, engineering design, and on-going experimental efforts will be reported here.

43 PARTICLE ACCELERATORS↗

Preliminary Results from Magnetic Field Scanning System for a Single-Cell Niobium Cavity

One of the building blocks of modern particle accelerators is superconducting radiofrequency (SRF) cavities. Niobium is the material of choice to build such cavities, which operate at liquid helium temperature (2 - 4 K) and have some of the highest quality factors found in Nature. There are several sources of residual losses, one of them is trapped magnetic flux, which limits the quality factor in SRF cavities. The flux trapping mechanism depends on different niobium surface preparations and cool-down conditions. Suitable diagnostic tools are not yet available to study the effects of such conditions on magnetic flux trapping. A magnetic field scanning system (MFSS) for SRF cavities using Hall probes and Fluxgate magnetometer has been designed, built, and is commissioned to measure the local magnetic field trapped in 1.3 GHz single-cell SRF cavities at 4 K. In this contribution, we will present the preliminary results from MFSS for a single cell niobium cavity.

Ciovati, G.↗

Liquid helium fluid dynamics studies. Final Technical Report

Future high energy physics accelerators depend on a number of advanced technologies to open the many doors of scientific discovery. Among these advanced technologies, superconducting magnets and superconducting radio frequency (SRF) cavities are the backbone of the accelerator and detector systems. But all these low temperature systems depend critically on successful and reliable operation of their supporting technologies, among which the liquid helium cooling system is of the utmost importance. To improve the quality of these systems both in terms of efficiency and reliability, a robust helium cryogenics research and development (R&D) effort is required. The proposed research to be conducted by the FSU cryogenics group aims to produce fundamental knowledge that meets this R&D need. The projects that we have completed over the past grant period at Florida State University consist of experimental research on liquid helium fluid dynamics and heat transfer problems relevant to the development of future superconducting particle physics accelerators. Liquid helium is the coolant used in all such facilities and in many of these facilities He II (the low temperature phase of liquid helium also known as superfluid helium) is preferred due to its outstanding heat transfer characteristics. The work consists of two main experimental studies that probe both fundamental as well as practical aspects of liquid helium cooling. The first is a broad and fundamental study of the heat and mass transfer processes that can occur during a sudden catastrophic loss of vacuum (SCLV) incident in a superconducting accelerator. SCLV refers to the remote but extremely critical accident scenario where atmospheric pressure air is allowed to flood into the insulating vacuum system and impinge on the liquid helium cooled surfaces in the accelerator. Safe performance and recovery from such accidents is essential to the reliable operation of superconducting accelerators. The dynamics of this process is quite complex and so our approach is to conduct a series of well-orchestrated experiments that probe the various physical phenomena that can occur during an SCLV event. The experiments are coupled with analytic and numerical analysis in an effort to develop a general understanding of the process and to assist with future accelerator design and development. The second activity is directed toward fundamental understanding of heat and mass transfer in He II, which is essential to the design of superconducting magnets and radio frequency cavities in accelerators. The work consists of flow visualization of the dynamics of He II using laser assisted techniques. Two complementary techniques are used to study the fundamentals of the turbulent state. The first technique uses neutrally buoyant solid hydrogen particles to probe the flow fields of the superfluid and normal fluid components. The other technique uses laser excited He2* molecules as tracers of the normal fluid motion within the He II. The activities also included an effort to use visualization techniques to locate transient hot spots in radio frequency superconducting cavities. Such work provides valuable information about the heat transfer process in He II and its impact on the performance of superconducting devices. The research effort at Florida State University is not directly in support of a specific high energy physics experiment or facility. Rather, the work is general and coordinated with HEP accelerator laboratories to provide valuable insight that can assist with future accelerator development.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

History of gradient advances in SRF

Radio frequency (RF) superconductivity has become a key technology for many modern particle accelerators. One of its most salient features of this technology is the ability of superconducting RF cavities to deliver high accelerating gradients in continuous-wave and long-pulse modes of operation. However, reaching the current state of the technology was not an easy fit. Over many years scientists and engineers had to overcome several serous performance limitations. In this paper, I attempt to the best of my knowledge to trace the history of accelerating gradients evolution in the field of superconducting radio frequency. I will restrict the scope to primary innovations along with some of the ensuing developments in developing cavities made of bulk niobium. But I will not cover all the many applications and findings over the subsequent decades of progress that were based on the primary discoveries and inventions. I will also not cover a number of other important topics in the history of cavity developments, such as the drive for higher Q values, or the push for lower cavity costs via Nb/Cu cavities or large grain Nb cavities.

43 PARTICLE ACCELERATORS↗

Field Emission Analysis in SRF Cavities for PIP-II Using GEANT4

Field emission (FE) remains a key limitation to achieving optimal performance and reliability in superconducting radiofrequency (SRF) cavities used in accelerator cryomodules. Addressing this challenge requires a detailed understanding of the generation and transport of FE-induced radiation; however, the absence of standardized measurement protocols complicates comparisons across different testing stages and facilities. This work presents initial steps toward a quantitative, systematic framework for analyzing FE-induced radiation using Geant4 simulations. We model four cavity types to be deployed in Fermilab’s Proton Improvement Plan-II (PIP-II) linac - HB650, LB650, SSR2, and SSR1 - to investigate radiation signatures and their dependence on emission conditions. By integrating simulation results with radiation diagnostics, our goal is to identify probable emission sites, enhance diagnostic accuracy, and optimize detector placement. Ultimately, this approach seeks to inform cavity preparation, assembly, and testing procedures, enabling the delivery of FE-free SRF cryomodules for PIP-II.

Wijethunga, Sajini [Fermilab] (ORCID:0000000287659↗