Search NASA⌕ Search

SEARCH · Search NASA

Results for “Active Mirrors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Icing Branch Current Research Activities in Icing Physics

Current development: A grid block transformation scheme which allows the input of grids in arbitrary reference frames, the use of mirror planes, and grids with relative velocities has been developed. A simple ice crystal and sand particle bouncing scheme has been included. Added an SLD splashing model based on that developed by William Wright for the LEWICE 3.2.2 software. A new area based collection efficiency algorithm will be incorporated which calculates trajectories from inflow block boundaries to outflow block boundaries. This method will be used for calculating and passing collection efficiency data between blade rows for turbo-machinery calculations.

Vargas, Mario↗

How to Calibrate Edge Sensors on Segmented Mirror Telescopes

The next generation of large ground based telescopes use segmented mirrors. Sensors mounted on the edge of the segments measure the relative heights of the segments. The segments are actively controlled in height by three actuators per segment, but lateral motion is only passively constrained. Thus there will be some small change in the gap and shear between segments as changing telescope orientation and temperature make small distortions in the telescope structure. These "in-plane" motions place an additional performance burden on the edge sensors, and on the precision with which they must be mounted relative to the optical surface. In addition, both the scaling and offset of sensor edge height readings also vary with changes in gap.

segmented mirrors↗

Active Nematic Ratchet in Asymmetric Obstacle Arrays

We numerically investigate the effect of an asymmetric periodic obstacle array in a two-dimensional active nematic. We find that activity in conjunction with the asymmetry leads to a ratchet effect or unidirectional flow of the fluid along the asymmetry direction. The directional flow is still present even in the active turbulent phase when the gap between obstacles is sufficiently small. We demonstrate that the dynamics of the topological defects transition from flow-mirroring to smectic-like as the gap between obstacles is made smaller, and explain this transition in terms of the pinning of negative winding number defects between obstacles. This also leads to a non-monotonic ratchet effect magnitude as a function of obstacle size, so that there is an optimal obstacle size for ratcheting at fixed activity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Highly Elliptic Circular Dichroism of Copper Aspartate One-Dimensional Nanostructures across the Ultraviolet to Terahertz Ranges

Since the discovery of chirality, circular dichroism (CD) of mirror-asymmetric molecules has been studied across the ultraviolet, visible, and near-infrared ranges. Recently, chiroptical activity studies have expanded to the terahertz (THz) range, where resonance peaks originate from collective vibrations of tens and hundreds of atoms. Here, in this study, we synthesized Cu 2+ coordination complexes with L- and D-aspartic acid as nanowires and nanorods and characterized their chiroptical activity across multiple frequency ranges. Both chiral nanostructures exhibit strong electronic CD (ECD), primarily from Cu 2+ d-d transitions, while vibrational CD (VCD) spectra show sharp C=O, C–H, and O–H vibronic peaks, indicating higher atomic defect densities in nanorods than nanowires. Although THz CD (TCD) spectra are broad, they exhibit ∼1000× greater ellipticity than ECD and VCD, perhaps warranting previous references to circular dichroism of nanostructures as giant. Comparative TCD analysis highlights strong chiral phonon sensitivity, underscoring its potential for probing defect densities and structural changes for various chiral nanostructures and (bio)crystals.

THz spectroscopy↗

Large Space Telescope Program status

This paper provides an overview of the current status of the LST Program. The history of the program is treated briefly, with emphasis placed on the recent Phase B definition activity. The background and rationale leading to the decision of the aperture size of the LST primary mirror are discussed. The current technical definition status of the LST Optical Telescope Assembly and Support Systems Module is treated in a summary fashion. Key milestone events during the balance of the Phase B definition effort and schedule and over-all planning for the development phase of the program are described.

Downey, J. A., III↗

Thermal design concept for a high resolution UV spectrometer

The thermal design concept described has been developed for the High Resolution UV Spectrometer/Polarimeter to be flown on the Solar Maximum Mission. Based on experience gained from a similar Orbiting Solar Observatory mission payload, it has been recognized that initial protection of the optical elements, contamination control, reduction of scattered light, tight bulk temperature, and gradient constraints are key elements that must be accommodated in any thermal control concept for this class of instrument. Salient features of the design include: (1) a telescope door providing contamination protection of an aplanatic Gregorian telescope; (2) a rastering system for the secondary mirror; (3) a unique solar heat absorbing device; (4) heat pipes and special radiators; (5) heaters for active temperature control and optics contamination protection; and (6) high precision platinum resistance thermometers. Viability of the design concept has been established by extensive thermal analysis and some subsystem testing. A summary of analytical and test results is included.

Caruso, P.↗

Large deployable reflector: An infrared and submillimeter orbiting observatory

The Large Deployable Reflector (LDR) is to be a dedicated astronomical observatory in space. It will operate in the 1 mm to 30 micron wavelength region where the Earth's atmospheric opacity makes ground-based observations nearly impossible. The primary mirror will be 20 m in diameter, made up of 37 individual segments. The reflector will be actively controlled to provide an overall surface accuracy of less than or approximately 2 microns. The LDR will be placed in orbit by the Space Shuttle and revisited at approximately 2 year intervals during its 10 year lifetime.

Swanson, P. N.↗

Evaluation of COSTAR mass handling characteristics in an environment. A simulation of the Hubble Space Telescope service mission

The STS-61 Shuttle mission, which took place in December 1993, was solely aimed at servicing the Hubble Space Telescope (HST). Successful completion of this mission was critical to NASA since it was necessary to rectify a flaw in the HST mirror. In addition, NASA had never scheduled a mission with such a high quantity of complex extravehicular activity. To meet the challenge of this mission, the STS-61 crew trained extensively in the Weightless Environment Test Facility at the Johnson Space Center and in the Neutral Buoyancy Simulator at the Marshall Space Flight Center. However, it was suspected that neutral buoyancy training might induce negative training by virtue of the viscous damping effect present in water. The mockups built for this training also did not have the mass properties of the actual orbital replacement units (ORUs). It was felt that the crew should be further trained on mockups with similar mass characteristics. A comprehensive study was designed to address these issues. The study was quantitative, and instrumentation was set up to measure and quantify the forces and moments experienced during ORU mass handling and remote manipulator system run conditions.

Rajulu, Sudhakar L.↗

Terrestrial Planet Finder coronagraph pointing control system design and evaluation for flight baseline 1.

The Terrestrial Planet Finder mission will search for Earth-like, extrasolar planets. The Coronagraph architecture option (TPF-C) will use contrast imaging to suppress the bright starlight in order to detect reflected visible light from the planet. To achieve the required contrast ratio stability of 2e-11, the payload pointing stability must be maintained to better than 4 milli-asec (1σ). The passive TPF-C pointing architecture uses a 3-stage control system combined with a 2- stage passive isolation system to achieve the required pointing accuracy. The active pointing stage includes reaction wheels used for coarse pointing of the spacecraft, a position controlled secondary mirror that provides intermediate alignment, and a Fine Guidance Mirror that provides fine steering control.

Dewell, Larry↗

Precision Thermal Control Technology to Enable Thermally Stable Telescopes

Abstract. The precision thermal control (PTC) project was a multiyear effort initiated in fiscal year 2017 to mature the technology readiness level (TRL) of technologies required to enable ultra-thermally stable ultraviolet/optical/infrared space telescope primary-mirror assemblies for ultra-high-contrast observations of exoplanets. PTC had three objectives: (1) validate thermal optical performance models, (2) derive thermal system stability specifications, and (3) demonstrate multi-zonal active thermal control. PTC successfully achieved its objectives and matured active thermal control technology to at least TRL-5. PTC’s key accomplishments are a demonstration of better than 2-mK root-mean-square stable thermal control of the 1.5-m ultra-low expansion (ULE®) Advanced Mirror Technology Development-2 (AMTD-2) mirror when exposed to thermal disturbances in a relevant thermal/vacuum environment, and the ability to shape the 1.5-m AMTD-2 mirror to picometer precision. Additionally, an analysis approach is demonstrated for quantifying thermally induced mid-spatial frequency error which can cause speckle noise in the coronagraph dark hole.

thermal control↗

Creating unstable velocity-space distributions with barium injections

Ion velocity-space distributions resulting from barium injections from orbiting spacecraft and shaped charges are discussed. Active experiments confirm that anomalous ionization processes may operate, but photoionization accounts for the production of the bulk of the barium ions. Pitch-angle diffusion and/or velocity-space diffusion may occur, but observations of barium ions moving upwards against gravity suggests that the ions retain a significant enough fraction of their initial perpendicular velocity to provide a mirror force. The barium ion plasmas should have a range of Alfven Mach numbers and plasma betas. Because the initial conditions can be predicted these active experiments should permit testing plasma instability hypotheses.

Pongratz, M. B.↗

Precision Thermal Control (PTC) Technology to Enable Thermally Stable Telescopes

The Precision Thermal Control (PTC) project was a multiyear effort initiated in Fiscal Year 2017 to mature the Technology Readiness Level (TRL) of technologies required to enable ultra-thermally stable ultraviolet/ optical/infrared (UVOIR) space telescope primary-mirror (PM) assemblies for ultra-high-contrast observations of exoplanets. PTC had three objectives: (1) validate thermal optical performance models, (2) derive thermal system stability specifications, and (3) demonstrate multi-zonal active thermal control. PTC successfully achieved its objectives and matured active thermal control technology to at least TRL 5. PTC’s key accomplishments are a demonstration of better than 2-mK root-mean-square (rms) stable thermal control of the 1.5-m ultra-low-expansion (ULE®) Advanced Mirror Technology Development-2 (AMTD-2) mirror when exposed to thermal disturbances in a relevant thermal/vacuum environment, and the ability to shape the 1.5-m AMTD-2 mirror to picometer precision.

thermal control↗

Artificial intelligence time series forecasting for feed-forward laser stabilization

Laser plasma accelerators, typically operating at 1–10 Hz repetition rates, have the ability to produce high-quality electron beams in compact, all-optical-driven configurations, with the electron beams uniquely suited for a wide variety of accelerator-based applications. However, fluctuations and drifts in the laser delivery to the meter-scaled and below plasma target (the electron beam source) will translate into electron beam source variations that can limit their utility for demanding applications like light sources or linear colliders. Commercially available active feedback laser stabilization systems are intrinsically bandwidth limited due to their integration with multi-inch corrective mirror mounts which minimizes their effectiveness. In this manuscript, we present a Neural Network time series forecaster that can predict laser position fluctuations of the laser delivery to the final target well ahead of a future laser shot. The Root-Mean-Square-Error (RMSE) of the prediction accuracy was < 2 μ m for a 1 / e 2 beam radius of 34 μ m . Our feed-forward approach serves as a first-step in circumventing the bandwidth limitations imposed by the currently available stabilization systems since it allows for mirrors to be moved into position ahead of time to offset the predicted future position drift. This will help advance laser plasma accelerator research by providing greater robustness and stability needed for its applications.

Berger, Curtis↗

Active figure maintenance control using an optical truss laser metrology system for a space-based far-IR segmented telescope

A two-stage active control approach was developed addressing the figure control problem for a spaceborne FIR telescope, the Precision Segmented Reflectors Focus Moderate Mission Telescope (FMMT). The first active control stage aligns the optical segments based on images; attention is here given to the second stage, active figure maintenance control system, which maintains the alignment of the optical elements between initializations to hold the mirror figure steady while obtaining data and fixes translational and rotational changes of the optical segments induced by long-term thermal drifts of the support structure. Errors are expected to be 10-100 microns at the nodes of the primary backup structure over the course of an orbit. An rms performance of 0.8 microns of wavefront error can be expected during the maintenance function based on specified nominal sensor noises, actuator accuracies, and system environments. A performance of less than 0.3 microns rms can be expected, based on advanced components.

Lau, Kenneth↗

Fingertip contact suppresses the destabilizing influence of leg muscle vibration

Touch of the hand with a stationary surface at nonmechanically supportive force levels (<1 N) greatly attenuates postural sway during quiet stance. We predicted such haptic contact would also suppress the postural destabilization caused by vibrating the right peroneus brevis and longus muscles of subjects standing heel-to-toe with eyes closed. In experiment 1, ten subjects were tested under four conditions: no-vibration, no-touch; no-vibration, touch; vibration, no-touch; and vibration, touch. A hand-held physiotherapy vibrator (120 Hz) was applied approximately 5 cm above the malleolous to stimulate the peroneus longus and brevis tendons. Touch conditions involved contact of the right index finger with a laterally positioned surface (<1 N of force) at waist height. Vibration in the absence of finger contact greatly increased the mean sway amplitude of the center of pressure and of the head relative to the no-vibration, no-touch control condition (P < 0.001). The touch, no-vibration and touch-vibration conditions were not significantly different (P > 0.05) from each other and both had significantly less mean sway amplitude of head and of center of pressure than the other conditions (P < 0.01). In experiment 2, eight subjects stood heel-to-toe under touch and no-touch conditions involving 40-s duration trials of peroneus tendon vibration at different duty cycles: 1-, 2-, 3-, and 4-s ON and OFF periods. The vibrator was attached to the subject's leg and remotely activated. In the no-touch conditions, subjects showed periodic postural disruptions contingent on the duty cycle and mirror image rebounds with the offset of vibration. In the touch conditions, subjects were much less disrupted and showed compensations occurring within 500 ms of vibration onset and mirror image rebounds with vibration offset. Subjects were able to suppress almost completely the destabilizing influence of the vibration in the 3- and 4-s duty cycle trials. These experiments show that haptic contact of the hand with a stable surface can suppress abnormal proprioceptive and motor signals in leg muscles.

NASA Discipline Neuroscience↗

Low-cost Large Aperture Telescopes for Optical Communications

Low-cost, large-aperture optical receivers are required to form an affordable optical ground receiver network for laser communications. Among the ground receiver station's multiple subsystems, here, we only discuss the ongoing research activities aimed at reducing the cost of the large-size optics on the receiver. Experimental results of two different approaches for fabricating low-cost mirrors of wavefront quality on the order of 100-200X the diffraction limit are described. Laboratory-level effort are underway to improve the surface figure to better than 20X the diffraction limit.

telescope↗

NASA Tech Briefs, February 2012

This issue contains the following briefs: (1) Optical Comb from a Whispering Gallery Mode Resonator for Spectroscopy and Astronomy Instruments Calibration (2) Real-Time Flight Envelope Monitoring System (3) Nemesis Autonomous Test System (4) Mirror Metrology Using Nano-Probe Supports (5) Automated Lab-on-a-Chip Electrophoresis System (6) Techniques for Down-Sampling a Measured Surface Height Map for Model Validation (7) Multi-Component, Multi-Point Interferometric Rayleigh/Mie Doppler Velocimeter (8) Frequency to Voltage Converter Analog Front-End Prototype (9) Dust-Tolerant Intelligent Electrical Connection System (10) Gigabit Ethernet Asynchronous Clock Compensation FIFO (11) High-Speed, Multi-Channel Serial ADC LVDS Interface for Xilinx Virtex-5 FPGA (12) Glovebox for GeoLab Subsystem in HDU1-PEM (13) Modified Process Reduces Porosity when Soldering in Reduced Gravity Environments (14) Use of Functionalized Carbon Nanotubes for Covalent Attachment of Nanotubes to Silicon (15) Flexible Plug Repair for Shuttle Wing Leading Edge (16) Three Dimensionally Interlinked, Dense, Solid Form of Single-Walled CNT Ropes (17) Axel Robotic Platform for Crater and Extreme Terrain Exploration (18) Site Tamper and Material Plow Tool - STAMP (19) Magnetic Interface for Segmented Mirror Assembly (20) Transpiration-Cooled Spacecraft-Insulation-Repair Fasteners (21) Fluorescence-Based Sensor for Monitoring Activation of Lunar Dust (22) Aperture Ion Source (23) Virtual Ultrasound Guidance for Inexperienced Operators (24) Model-Based Fault Diagnosis: Performing Root Cause and Impact Analyses in Real Time (25) Interactive Schematic Integration Within the Propellant System Modeling Environment (26) Magnetic and Electric Field Polarizations of Oblique Magnetospheric Chorus Waves (27) Variable Sampling Mapping.

Source record↗

Charter and activities of the SIRTF in-orbit checkout focus integrated products team and optical performance of the CTA

We describe a strategy to determine the initial mirror spacing by quantitatively evaluating the shapes of the images formed by the telescope using the Infrared Array Camera and other science instruments. We show that this information can be used to predict the direction and magnitude of the secondary mirror move that will result in the telescope best focus. The tools used to evaluate focus position and optical quality of the in orbit CTA have been qualified during the BRUTUS test are here described.

Integrated↗