Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advanced Sensors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Measurement of Photons Emitted by High-Energy Charged Particles as Background in Single-Photon Resolving Image Sensors

This work introduces an advanced technique optimized for detecting photons generated by charged particles, leveraging Skipper charge coupled device (Skipper-CCD) image sensors. By analyzing background sources and detection efficiencies, the technique achieves strong agreement between experimental results and Cherenkov-based simulations. It also provides a robust framework for investigating secondary photon production in environments with high fluxes of ionizing particles, such as those anticipated in space-based astronomical instruments. These secondary photons present a critical challenge as background noise for next-generation single-photon resolving imagers used to study faint celestial objects. Furthermore, the method exhibits significant potential for broader applications, including exploring photon generation in various substrate materials and examining their transport through multiple interfaces.

Fernandez Moroni, Guillermo [Fermilab; Chicago U.,↗

Materials for Gamma Radiation Sensors

Sensors used for spectroscopic measurements of gamma radiation are most often scintillator or semiconductor materials. An overview is provided in this chapter on the materials and development techniques used in producing spectroscopic gamma radiation sensors. Challenges that prevent a perfect sensor are discussed along with the reasons why some sensor materials are ubiquitous despite their performance limitations. The types of sensors commonly used as detectors are discussed along with their key physical properties and electronic characteristics. Materials commonly utilized in radiation detectors are then reviewed to highlight how sensor materials have advanced since the earliest gamma detectors were developed

Johns, Paul M.↗

Single-atom materials boosting wearable orthogonal uric acid detection

Abstract Uric acid (UA) is a vital biomarker for the diagnosis and management of various health conditions, including cardiovascular diseases, gout, kidney disorders, metabolic syndrome, and wound healing. Despite significant advances in wearable sensor technology, challenges persist in developing wearable sensors that are capable of maintaining high sensitivity, selectivity, and stability. In this study, we present an epidermal sensing platform enhanced with single-atom materials (SAMs) designed for flexible and orthogonal electrochemical detection of UA. We designed and synthesized an SAM with Fe-N 5 active sites to boost the electrochemical sensing signals, integrating it with laser-engraved graphene (LEG) to fabricate a wearable SAM-based UA patch sensor. This design provides superior UA detection performance compared to sensors based on conventional nanomaterials. In addition, we enhanced the detection accuracy and range by using an orthogonal approach that combines direct oxidation through differential pulse voltammetry (DPV) along with parallel biocatalytic amperometric detection. The resulting SAM-based UA orthogonal sensor patch demonstrated exceptional performance in wearable applications through tests measuring sweat UA levels in subjects before and after consuming a purine-rich diet. Graphical Abstract

Ding, Shichao↗

Development of a new control rod drive mechanism design for the ISU AGN-201M reactor

The Aerojet General Nucleonics (AGN) model 201-Modified, known as the AGN-201M reactor, plays an essential role in the educational and research activities at Idaho State University (ISU). The ISU AGN-201M's original Control Rod Drive Mechanism (CRDM) has been in operation for more than fifty years with no large-scale redesigns. The CRDM is required to eject the fuel rods within one second during a SCRAM event (also known as a 'reactor trip') and adjust the control rods' insertion speed, and keeps the rod insertion sequence correct. The existing control rod drive mechanisms meet these criteria but experience a few concerns due to aging. Concerns include complex maintenance and costly repairs for old electromechanical components, rod position feedback errors, and the impediment of the plate during a SCRAM due to binding of the lead screws of the existing mechanism. During a binding event, the drive mechanism becomes locked, preventing the control rod's magnetic plate from moving in or out under the reactor's normal and emergency operating conditions. Although, the binding has no effect on the ability of the rod to exit the core during the SCRAM. To counteract the concerns and issues with the current CRDM, a new design has been proposed using newer components and a simplified design. The new design utilizes more advanced electric and mechanical components that are commercially available. The new CRDM system is divided into four main aspects: (1) control rod movement design (motor, lead screw, guide rods), (2) control rod ejection (springs, electromagnet), (3) control rod position and feedback (position transducer, microswitches), and (4) material selection and structural analysis. The new design aims to reduce the overall complexity and probability of failure to improve the reactor's overall reliability. With proper material selection and improved structural design, the new drives are lighter with little to no change in structural integrity. The new control rod drive mechanism eliminates binding scenarios by using a single lead screw and implementing additional guide rods. An advanced linear position sensor and microswitches replace the existing and aging synchro system for accurate rod position feedback resulting in better reactivity control. The new design meets the reactor's operational limits by having an average reactivity insertion of 0.065% Δk/k per second, which corresponds to a total control rod insertion time of 19.23 s, while the control rod's ejection time remains less than one second during a SCRAM event. The new design ensures the reactor's long-term viability for educational and research activities by increasing the reliability and safety of operation for years to come.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance of low-cost indoor air quality monitors for PM 2.5 and PM 10 from residential sources

Advances in particle sensor design and manufacturing have enabled the development of low-cost air quality monitors (LCMs). Here, the sensors use light scattering to estimate mass concentration and thus require evaluation for aerosols of varied composition and size distribution. We tested the performance of six LCMs designed for home use and having a retail price under US$300 in October 2018. We assessed their performance by comparing their output to reference PM 2.5 and PM 10 measurements from 21 common residential sources and from infiltrated outdoor PM 2.5 . Reference data were obtained by using gravimetric measurements to adjust time-resolved output from an aerosol spectrometer with both electrical mobility and optical particle sensors. Compared by linear regression to reference measurements, LCMs had negative intercepts and slopes of 1–2 for infiltrated outdoor PM 2.5 . Semi-quantitative responses (~50–200% of actual PM 2.5 ) were obtained for varied aerosols including minerals (ultrasonic humidifier, vacuuming, test dust); combustion products (incense, mosquito coil, extinguished candles); microwave popcorn; and cooking involving frying or grilling. LCMs had low or no response to sources for which all mass was in particles smaller than 0.25 μm, including steady candle flames and cooking without frying or grilling. PM 10 data from LCMs was more variable than PM 2.5 .

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cascaded Sapphire Fiber Bragg Gratings Inscribed by Femtosecond Laser for Molten Steel Studies

This research reports a distributed fiber optic high-temperature sensing system tailored for applications in the steel industry and various other sectors. Recent advancements in optical sensor technology have led to the exploration of sapphire crystal fibers as a solution for sensing in harsh environments. Utilizing a femtosecond (fs) laser, cascaded fiber Bragg gratings (FBGs) were meticulously fabricated within a multimode sapphire optical fiber. These FBGs endowed the system with distributed sensing capabilities and underwent rigorous testing under extreme temperatures, reaching up to 1800 °C. Here, the study delves into the investigation of the FBG reflection spectrum, facilitated by the development of a sophisticated multimode demodulation system, which contributed to the attainment of precise temperature measurements with a performance accuracy of 99.9%. Demonstrating exceptional thermal stability, the sapphire FBGs endured temperatures of 1600 °C for a sustained duration of 22 h. Furthermore, this article explores the application of distributed temperature sensing employing multiple sapphire FBGs, showcasing their utility in temperature measurements related to molten steel studies.

47 OTHER INSTRUMENTATION↗

Origin and mitigation of wind noise on balloon-borne infrasound microbarometers

High-altitude monitoring of low-frequency acoustic waves (infrasound) on Earth has regained prominence in recent years, primarily driven by improvements in light-weight sensor technology and advances in scientific ballooning techniques. Balloon-borne infrasound monitoring is also being proposed as a remote sensing technique for planetary exploration. Contrary to ground-based infrasound monitoring, the infrasound noise background in the stratosphere as measured by a balloon remains uncharacterized and the efficacy of wind noise mitigation filters has not been investigated. In this study, an analysis of pressure data collected using infrasound microbarometers during the flight of a long-duration zero pressure balloon is presented. Here, a dramatic reduction of background noise in the stratosphere is demonstrated and it is shown that wind noise mitigation filters are not effective at reducing wind noise under these conditions. Results from this study demonstrate stratospheric balloons as a low-noise platform for infrasound monitoring and motivate the development of improved noise mitigation tools.

47 OTHER INSTRUMENTATION↗

Five Year Wildfire Risk Reduction Action Plan for the Electric Power Industry

The U.S. DOE and the Electric Power Research Institute convened a wildfire advisory group to bring together knowledge of ignition risks, electric utility needs, the applicability of available technology, and existing technology gaps. The outcome is a five-year action plan, containing recommendations on RD&D projects, that if completed by the year 2030, may accelerate the power industry’s ability to substantially reduce wildfire ignition risks. When reviewing this document please consider it is a snapshot in time for the years 2023 and 2024, could be obsolete by the end of the decade. The following list comprises the titles and topics for the proposed follow-on demonstrations: 1. Hybrid Undergrounding RD&D, 2. Live Downed Conductor Detection RD&D, 3. Fault Energy Reduction RD&D, 4. Advanced Inspection and Response Drone, 5. Fault and PQ Event Signature Repository, 6. Advanced and Intelligent Sensor Nodes, 7. Fire Friendly Asset Coatings and Coverings, and 8. Environmental Monitoring Action Plan.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Simple and Accurate Energy-Detector-Based Transient Waveform Detection for Smart Grids: Real-World Field Data Performance

Integration of distributed energy sources, advanced meshed operation, sensors, automation, and communication networks all contribute to autonomous operations and decision-making processes utilized in the grid. Therefore, smart grid systems require sophisticated supporting structures. Furthermore, rapid detection and identification of disturbances and transients are a necessary first step towards situationally aware smart grid systems. This way, high-level monitoring is achieved and the entire system kept operational. Even though smart grid systems are unavoidably sophisticated, low-complexity algorithms need to be developed for real-time sensing on the edge and online applications to alert stakeholders in the event of an anomaly. In this study, the simplest form of anomaly detection mechanism in the absence of any a priori knowledge, namely, the energy detector (also known as radiometer in the field of wireless communications and signal processing), is investigated as a triggering mechanism, which may include automated alerts and notifications for grid anomalies. In contrast to the mainstream literature, it does not rely on transform domain tools; therefore, utmost design and implementation simplicity are attained. Performance results of the proposed energy detector algorithm are validated by real power system data obtained from the DOE/EPRI National Database of power system events and the Grid Signature Library.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Leveraging FPGA Advantages for Quicker Data Processing for LBNF

The Long Baseline Neutrino Facility (LBNF) will deliver a 2.4 MW muon neutrino beam from Fermilab to the Deep Underground Neutrino Experiment (DUNE), requiring unprecedented precision in beamline alignment to achieve DUNE's neutrino oscillation measurement goals. Vertical misalignments of beamline components as small as 0.5 mm can contribute 6-7\% uncertainty in predicted neutrino flux, necessitating sub-0.1 mm alignment monitoring capabilities. The Horn Location Sensor (HLS) system employs frequency sweep interferometry (FSI) in a distributed hydrostatic leveling network to achieve the required precision under harsh radiation conditions up to 5000 kRad/year. Traditional FSI implementations suffer from laser sweep nonlinearities that degrade resolution and require computationally intensive post-processing corrections using gas reference cells. This work presents a real-time FPGA-based implementation of the HLS data acquisition and processing system using a sweep tracker interferometer for dynamic sweep linearization. The system utilizes a PYNQ-Z2 FPGA with programmable logic implementing parallel 16k-point FFT processing across four channels, synchronized by the sweep tracker signal to eliminate post-processing requirements. Spectral performance testing demonstrates significant improvements in peak sharpness compared to traditional fixed-frequency digitization. The FPGA implementation enables real-time displacement monitoring with processing speeds orders of magnitude faster than software-based approaches, essential for the operational requirements of LBNF's eventual distributed sensor network. This advancement in real-time FSI processing directly supports DUNE's precision neutrino physics program by providing the rapid feedback necessary for maintaining stringent beamline alignment tolerances during high-power beam operations.

Rossel, Jacob↗

Real-Time FPGA Implementation For Frequency Sweep Interferometry In The LBNF Complex

The Long Baseline Neutrino Facility (LBNF) will deliver a 2.4 MW muon neutrino beam from Fermilab to the Deep Underground Neutrino Experiment (DUNE), requiring unprecedented precision in beamline alignment to achieve DUNE's neutrino oscillation measurement goals. Vertical misalignments of beamline components as small as 0.5 mm can contribute 6-7\% uncertainty in predicted neutrino flux, necessitating sub-0.1 mm alignment monitoring capabilities. The Horn Location Sensor (HLS) system employs frequency sweep interferometry (FSI) in a distributed hydrostatic leveling network to achieve the required precision under harsh radiation conditions up to 5000 kRad/year. Traditional FSI implementations suffer from laser sweep nonlinearities that degrade resolution and require computationally intensive post-processing corrections using gas reference cells. This work presents a real-time FPGA-based implementation of the HLS data acquisition and processing system using a sweep tracker interferometer for dynamic sweep linearization. The system utilizes a PYNQ-Z2 FPGA with programmable logic implementing parallel 16k-point FFT processing across four channels, synchronized by the sweep tracker signal to eliminate post-processing requirements. Spectral performance testing demonstrates significant improvements in peak sharpness compared to traditional fixed-frequency digitization. The FPGA implementation enables real-time displacement monitoring with processing speeds orders of magnitude faster than software-based approaches, essential for the operational requirements of LBNF's eventual distributed sensor network. This advancement in real-time FSI processing directly supports DUNE's precision neutrino physics program by providing the rapid feedback necessary for maintaining stringent beamline alignment tolerances during high-power beam operations.

Rossel, A. Jacob [Fermilab; Unlisted]↗

Novel Temperature Sensors and Wireless Telemetry for Active Condition Monitoring of Advanced Gas Turbines

The objective of the program is to develop and engine test hardware and software technologies that will enable active condition monitoring to be implemented on hot gas path turbine blades in large industrial gas turbines. The specific objectives are (1) to fabricate and install Smart Turbine Blades with thermally sprayed sensors and high temperature wireless telemetry systems in a gas turbine engine, (2) to integrate the component engine test data with remaining useful life (RUL) models and develop an approach for networking the component RUL data with Siemens' Power Diagnostics® engine monitoring system. These significant advances carried out in Phase 1 in temperature wide bandgap telemetry, along with new induced power driver and receiver geometry combined with an innovative approach to transmit digital data wirelessly will enable the opportunity to proceed with more technical innovation. The Phase 2 program focused on validation testing of sensor-wireless telemetry package in spin rig and advanced operation-based assessment (OBA) model utilizing artificial intelligence. Significant efforts were dedicated on the download of the technology onto components to be tested an actual gas turbine engine for full realization of active condition monitoring for Smart Turbine Blades.

03 NATURAL GAS↗

Demonstration of Multi-Gamma Based Sensor Technology for As-Fired Coal Property Measurement

This project demonstrated the application of the use of an advanced multigamma attenuation (MGA) sensor to accurately and precisely measure coal properties at the point of injection into burners. Accurate and precise coal property information at the burner provides the opportunity to adjust burner parameters to better follow changing load condition, optimize flame stability, and decrease nitrogen oxide formation at each burner. In addition, coal property information at the burner will assist in managing slag flow behavior, fireside ash related deposition, corrosion, and erosion issues. The advantage of having multiple gamma emitters is that the atomic/elemental interaction with the gamma energy takes place at several energies and the resulting attenuation is dependent upon the atomic number of the atom/element encountered in the coal.

01 COAL, LIGNITE, AND PEAT↗

First Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing: Development of Sensor Performance Model of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. Feasibility of the sensor was initially investigated with analytical derivations and with COMSOL RF Module computer simulations of resonant frequency spectral shift due to uniform load. We also investigated the mechanical integrity of the flowmeter’s membrane through analytical modelling and COMSOL Structural Mechanics Module computer simulations. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the material’s yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure. Using results from models, we have developed an initial design for a microwave K-band sensor. A cylindrical resonator prototype was fabricated from brass for the initial tests. The external dimensions of the cavity are matched to the flange of a standard WR-42 waveguide. Microwave field is coupled into the resonant cavity through a subwavelength-size aperture. A test article was developed consisting of a piping Tee with a bulkhead WR-42 microwave waveguide installed in a leak-proof assembly. A microwave waveguide circulator was installed in the setup to suppress the effect of reflections at the cavity entrance by increasing the isolation between the input and the output port. Preliminary spectral characterization of cavity spectral response was performed with a portable PXIe chassis microwave VNA with a custom GUI. Preliminary dry tests of the transducer response were conducted with a set of calibrated weights. Transducer frequency shift was shown to be monotonically increasing with increasing pressure. The next steps will involve investigation of the transducer performance for water flow sensing.

42 ENGINEERING↗

Demonstration of Microwave Resonant Cavity Transducer Performance in Fluid Flow Sensing: Development of Sensor Performance Model of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. To validate sensor physics, we have performed proof-of-principle test of flow sensing in water. For this test, we have developed a cylindrical resonator for K-band, which was machined from brass. The cavity was excited through WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder. To increase the spectral signal visibility, we developed a signal processing method for baseline subtraction. A flow loop for proof-of-principle test of transducer performance in water was assembled. A commercial flow meter was installed in the loop for reference measurements. Cylindrical cavity was excited in the TEM 011 mode with resonant frequency f ≈ 17.8GHz. Frequency shift of cavity spectral response was obtained by gradually increasing water flow rate from 0 to 60gpm. Corresponding monotonic increase of resonant frequency shift by several MHz was observed.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Integration of Next Generation Critical Infrastructure Sensor Technologies

This project is focused on advancing current protective relaying and control through verifying next generation timing systems and sensors with current commercial off the shelf protective relays. This will further research in the field of advanced grid modernization and demonstrate interoperability between nextgeneration protective relays and voltage and current sensors. These commercial off the shelf (COTS) technologies were tested and integrated with next generation sensor technologies, with the results documented below.

47 OTHER INSTRUMENTATION↗

Hard X-ray Fluorescence measurements with TESs at the Advanced Photon Source

Transition Edge Sensor (TES) spectrometers for hard X-ray beamline science will enable improved X-ray emission and absorption spectroscopy in the information-rich 2 to 20keV energy range. We are building a TES-based instrument for time Advanced Photon Source (APS) synchrotron, to be made available to beamline users. 24-pixel prototype arrays have recently been fabricated and tested. the first, spectroscopy measurements using these arrays are promising, with a best single-pixel energy resolution of 11.2 eV and saturation energy > 20 keV. We present a series of recent X-ray Fluorescence measurements involving transition metal elements and multi-element samples with closely spaced emission lines, in particular a Cu-Ni-Co thin film and a foil of Cu and Hf, The TES-measured spectra are directly compared to spectra measured with silicon drift detectors at an APS beamline, demonstrating the improved X-ray science made possible by TES spectrometers.

Guruswamy, Tejas↗

Comprehensive defect evaluation of advanced nuclear fuels using high-resolution acoustic signals and optimized sensor separation

Graphite pebble composite structures based on TRistructural-ISOtropic (TRISO) particles are being developed as core nuclear fuels in advanced power reactors, promising safe operation at increased temperatures. Ensuring the structural integrity of these nuclear fuels requires comprehensive and accurate non-destructive evaluation (NDE) techniques to characterize defects and damage in the pebbles. However, traditional acoustic evaluation methods face limitations in defect characterization due to the highly attenuative, and geometrically and compositionally complex nature of these structures. This study proposes an improved acoustic NDE technique for accurate detection and classification of anticipated relevant defects and damage in graphite pebbles using high-resolution acoustic signals and optimized transmit-receive sensor networks. The proposed approach utilizes a triangular three-sensor network as the base unit, comprising three transmit-receive sensors. The sensor separation distance, as well as acoustic excitation center frequency, pulse-width, and bandwidth are optimized to enhance spatial resolution and improve signal-to-noise ratio, enabling effective characterization of the smallest size and widest range of defects in pebbles. Furthermore, the use of the triangular sensor configuration instead of a more conventional transmit-receive sensor pair expands the inspection region from a one-dimensional linear path to a two-dimensional area, increasing spatial coverage. To mitigate challenges associated with processing of complex acoustic signals arising from high-frequency, high-bandwidth excitation in these structures, a machine-learning-based signal processing algorithm is integrated with the sensor network. In the machine-learning-based algorithm, multi-domain features are extracted from the acoustic signals to capture intricate signal characteristics, significantly improving defect identification and classification compared to traditional approaches. The proposed acoustic NDE technique offers considerable promise for practical and reliable defect/damage diagnostics of advanced nuclear pebble fuels.

42 ENGINEERING↗