Search NASA⌕ Search

SEARCH · Search NASA

Results for “Air Bearing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Real-Time EVA Troubleshooting

Dr. Parazynski focused on the Shuttle Transportation System (STS)-120 Solar Array Repair Extravehicular Activity (EVA) with personal anecdotes and then spoke about what it takes to have a successful EVA during the event, what types of problems can occur during an EVA, particularly with the spacesuit and the safety of the crew, and how to resolve these quickly, safely, and efficiently. He also described the participants and the types of decisions and actions each had to take to ensure success. He described "Team 4," in Houston and on-orbit, as well as anecdotes from his STS-86 and STS-100 missions. Parazynski provided a retrospective on the EVA tools and procedures NASA used in the aftermath of Columbia for shuttle Thermal Protection System (TPS) inspection and repair. He described his role as the lead astronaut during this effort, and covered all the Neutral Buoyancy Laboratory (NBL), KC-135, precision air-bearing floor (PABF), vacuum chamber, and 1-G testing performed to develop the tools and techniques that were flown. Parazynski discussed how the EVA community worked together to resolve a huge safety issue, and how his work in the spacesuit was critical to overcoming a design limitation of the Space Shuttle.

Parazynski, Scott↗

Ground Demonstration on the Autonomous Docking of Two 3U CubeSats Using a Novel Permanent-Magnet Docking Mechanism

Small spacecraft autonomous rendezvous and docking is an essential technology for future space structure assembly missions. A novel magnetic capture and latching mechanism is analyzed that allows for docking of two CubeSats without precise sensors and actuators. The proposed magnetic docking hardware not only provides the means to latch the CubeSats but it also significantly increases the likelihood of successful docking in the presence of relative attitude and position errors. The simplicity of the design allows it to be implemented on many CubeSat rendezvous missions. A CubeSat 3-DOF ground demonstration effort is on-going at NASA Langley Research Center that enables hardware-in-the loop testing of the autonomous approach and docking of a follower CubeSat to an identical leader CubeSat. The test setup consists of a 3 meter by 4 meter granite table and two nearly frictionless air bearing systems that support the two CubeSats. Four cold-gas on-off thrusters are used to translate the follower towards the leader, while a single reaction wheel is used to control the attitude of each CubeSat. An innovative modified pseudo inverse control allocation scheme was developed to address interactions between control effectors. The docking procedure requires relatively high actuator precision, a novel minimal impulse bit mitigation algorithm was developed to minimize the undesirable deadzone effects of the thrusters. Simulation of the ground demonstration shows that the Guidance, Navigation, and Control system along with the docking subsystem leads to successful docking under 3-sigma dispersions for all key system parameters. Extensive simulation and ground testing will provide sufficient confidence that the proposed docking mechanism along with the choosen suite of sensors and actuators will perform successful docking in the space environment.

Pei, Jing↗

Developing a 3-DOF Compliant Perching Arm for a Free-Flying Robot on the International Space Station

This paper presents the design and control of the 3-DOF compliant perching arm for the free-flying Astrobee robots that will operate inside the International Space Station (ISS). The robots are intended to serve as a flexible platform for future guest scientists to use for zero-gravity robotics research - thus, the arm is designed to support manipulation research. It provides a 1-DOF underactuated tendon-driven gripper capable of enveloping a range of objects of different shapes and sizes. Co-located RGB camera and LIDAR sensors provide perception. The Astrobee robots will be capable of grasping each other in flight, to simulate orbital capture scenarios. The arm's end-effector module is swappable on-orbit, allowing guest scientists to add upgraded grippers, or even additional arm degrees of freedom. The design of the arm balances research capabilities with Astrobee's operational need to perch on ISS handrails to reduce power consumption. Basic arm functioning and grip strength were evaluated using an integrated Astrobee prototype riding on a low-friction air bearing.

Park, In-Won↗

Trajectory Generation for Flexible-Joint Space Manipulators

Space manipulator arms often exhibit significant joint flexibility and limited motor torque. Future space missions, including satellite servicing and large structure assembly, may involve the manipulation of massive objects, which will accentuate these limitations. Currently, astronauts use visual feedback on-orbit to mitigate oscillations and trajectory following issues. Large time delays between orbit and Earth make ground teleoperation difficult in these conditions, so more autonomous operations must be considered to remove the astronaut resource requirement and expand robotic capabilities in space. Trajectory planning for autonomous systems must therefore be considered to prevent poor trajectory tracking performance. We provide a model-based trajectory generation methodology that incorporates constraints on joint speed, motor torque, and base actuation for flexible-joint space manipulators while minimizing total trajectory time. Full spatial computer simulation results, as well as physical experiment results with a single-joint robot on an air bearing table, show the efficacy of our methodology.

Space robotics↗

REACCH - Reactive Electro-Adhesive Capture ClotH Mechanism to Enable Safe Grapple of Cooperative/Non-Cooperative Space Debris

USC’s Space Engineering Research Center (SERC) and the Jet Propulsion Laboratory (JPL) have created a unique “octopus” tentacle end effector for robotic systems that uses formable electro-adhesion (EA) and Gecko adhesion capture cloth material. REACCH, or Reactive Electro-Adhesive Capture ClotH, supports soft capture of objects of any size, shape, surface finish or material on-orbit. To-date SERC/JPL have developed initial tentacles and backing spines that can control the EA/G material. Prototypes with two tentacles have been demonstrated and tested on a 3-DOF air bearing device in 1g in one plane of grip. The results show promise to further develop this new type of grappling mechanism able to make first soft contact with an object, with a technology that merges compliance and control elements for future on-orbit servicing and assembly missions. This paper presents the initial design and test results on this type of system.

Narayanan, Sriram↗

Countermeasures for Mitigation of Sensorimotor Decrements Following Head-Down Bed Rest

BACKGROUND Astronauts experience postflight disturbances in postural and locomotor control due to sensorimotor adaptations during spaceflight. These alterations may have adverse consequences if a rapid egress is required after landing. Although exercise is partially effective for mitigating cardiovascular and muscular deconditioning, additional countermeasures are needed to further preserve sensorimotor function for exploration missions. We have identified proprioceptive training and electrical muscle stimulation (EMS) as promising in-flight countermeasures. Since prolonged head down bed rest (HDBR) is a spaceflight analog for body unloading and causes postural and locomotor control decrements that parallel those observed after spaceflight, it can be used to accelerate the development of these countermeasures. METHODS This study will determine the effects of proprioceptive training and EMS on functional task performance and sensorimotor function following 60 days of 6° HDBR. Subjects will be randomly assigned to one of four groups: 1) an EMS arm, 2) a proprioceptive training arm, 3) an exercise plus proprioceptive training arm, and 4) a control arm. The EMS countermeasure will include daily bilateral stimulation of the quadriceps femoris muscle (30 minutes per session). Proprioceptive training will be performed three days per week (20 minutes per session) consisting of body-loaded postural tasks in the horizontal position on an air bearing sled. Exercise training will mimic current protocols used on the International Space Station, but treadmill aerobic exercise will be replaced with additional cycling aerobic exercise. Primary outcome measures will include pre and post HDBR functional tests that are representative of high priority exploration mission tasks and require high demand for dynamic control of postural stability. Additional measures will be used to identify the key physiological factors contributing to countermeasure benefits. Given the constrained samples size, a Bayesian modelling approach will be used to quantify the probability that there is an effect of a given magnitude. COUNTERMEASURE UPDATES Proprioceptive countermeasure design enhancements and human in the loop pilot testing continued through the Crew Health Countermeasures (CHC) Systems Capability Leadership Team (SCLT). The primary goals of this work were to enhance the visual feedback system’s capabilities and develop a proprioceptive training program for 60 days of HDBR. Six healthy non-astronaut volunteers participated in four pilot training sessions to systematically examine how each training variable (e.g., axial load, foot placement, and software profile) affects the overall proprioceptive challenge. The resulting training program will maintain an appropriate challenge during 60 days of HDBR by progressively decreasing the subject’s base of support, increasing tilt board target distances, and increasing axial loads using both subjective verbal feedback and objective performance data. RELEVANCE The deliverable from this project will be proof-of-concept sensorimotor countermeasure designs for functional task performance with full assessment of efficacy in a spaceflight analog. If the countermeasures are effective, they will be translated for validation with the suite of operationally implemented in-flight countermeasures.

T R Macaulay↗

Assessing the Relationships Between Sensorimotor Biomarkers and Post-Landing Functional Task Performance

Spaceflight drives adaptive changes in healthy individuals appropriate for sensorimotor function in a microgravity environment. These changes are maladaptive for return to earth's gravity. The inter-individual variability of sensorimotor decrements is striking, although poorly understood. The goal of this study is to identify a set of behavioral, neuroimaging and genetic measures that can be used to predict early post-flight performance on a set of sensorimotor tasks. Astronauts are recruited who previously participated in sensorimotor field tests and/or posturography soon after long-duration spaceflight. Behavioral tests include assessments of sensory dependency and adaptability. Visual dependency involves treadmill walking while viewing a moving virtual visual scene. Vestibular thresholds are measured while seated during lateral translations. Proprioception dependency is measured during one-legged stance on a horizontal air-bearing surface. Ground assessment of adaptability is performed (1) during treadmill walking with a virtual linear hallway and a moving walking surface, and (2) during multiple trials of navigating an obstacle course while wearing reversing prisms. The neuroimaging tests will characterize individual differences in regional brain volumes (using Structural MRI) and white matter microstructure (using Diffusion Tensor Imaging) to serve as potential predictors of adaptive capacity. The genetic tests will utilize saliva samples to examine variations in four genes chosen because of their ability to differentiate sensorimotor adaptation ability in a normative population, including Catechol-O-methyltransferase (COMT), Dopamine Receptor D2 (DRD2), Brain-derived neurotrophic factor (BDNF) and the α2-adrenergic receptor. Twenty-one ISS crewmembers have been tested to date, including 6 from this past year after testing resumed post-COVID. This cohort includes 9 first-time fliers, 4F, and mission durations lasting 182 ± 32 days, mean ± std. We are utilizing a combination of three post-flight functional task outcomes: tandem walk, recovery from fall and dynamic posturography. There is considerable variability among the post-flight performance outcomes for the 21 participants to date. Based on a partial sample using an ordinal scale survey, 80% indicated their ability to perform functional tasks were more impacted postflight relative to inflight with 50% indicating they needed to restrict movements for a longer period postflight relative to inflight. While there is a strong association within tests obtained at different R+0 timepoints, by R+24 hr performance on one post-flight test does not necessarily correlate with performance on other post-flight tests. There are apparent relationships between individual measures and specific post-flight outcome measures; however, additional data is needed to draw conclusions. Preliminary statistical analysis indicates combining biomarkers will increase predictive power and this will be explored with future analyses. Our preliminary findings underscore the importance of a comprehensive post-flight test battery including different types of tasks with varying sensory feedback. We expect that understanding the relationships between these sensorimotor biomarkers and post-flight functional task performance will improve both our understanding of the individual variability and our strategy to optimize sensorimotor countermeasures.

S J Wood↗

Evaluating The Relationships Between Supine Propriorception Assessments with Upright Functional Mobility and Balance Tests

INTRODUCTION Upon return to Earth, spaceflight sensorimotor adaptations can result in impaired posture and locomotion [1], [2], and current exercise countermeasures in the International Space Station are not sufficient to maintain sensorimotor function. In-flight countermeasures and assessment tools for sensorimotor function are needed to mitigate risks associated with mission-critical task performance upon return to Earth or arrival to 0.38 G on Mars. One proposed countermeasure for proprioceptive deconditioning includes training on a tilt board device [3], which will be tested in an upcoming bed rest study. In preparation for the said study, the objective of this pilot study is to compare performance in supine proprioceptive assessments to performance in functional upright activities. The results are intended to guide the selection of supine assessment tools for the upcoming bedrest study and the development of future inflight proprioceptive training and assessment tools for exploration missions. METHODS Seventeen healthy participants (8 males and 9 females, 27.9 ± 8.5 years) provided informed consent as approved by the Institutional Review Board (IRB) at NASA. A horizontal air-bearing sled was used to provide a proprioceptive challenge in a supine body orientation, allowing for mediolateral motion with minimal friction during supine stance [4]. Participants were loaded axially (30 to 60% body weight) with their feet on a vertically oriented tilt board and instructed to perform supine assessment activities using custom software that displays a cursor controlled by tilting the tilt board. In a single-leg static activity on the tilt board (TB-St), performance was measured as the percent time spent on a center target during a 30-second trial. During a two-feet dynamic activity on the tilt board (TB-Dy), performance was measured as the number of targets captured in 30 seconds. These supine tasks were compared to performance during two upright activities used to represent upright performance: completion time for a functional mobility task (FMT) [2],[5] and a performance score from force plate sway data during 30-second single-leg upright standing (USL). RESULTS AND DISCUSSION A Spearman's rank-order correlation was run to assess the relationship between upright and supine assessments. There were statistically significant, strong correlations between scores for the FMT and each TB activity, including TB-St, rs(17) = 0.50, p<0.05, TB-Dy3, rs(17) = 0.73, p<0.001, and TB-Dy9, rs(15) = 0.53, p<0.05. There were no statistically significant correlations between USL and each TB activity. Despite a lack of correlation with upright single-leg balance, the ability of the TB to indicate upright performance in the FMT is promising, as this task is a standard post-flight measure designed to characterize locomotor dysfunction [2], [5]. CONCLUSION These efforts will inform the selection of an appropriate sensorimotor assessment method for the upcoming bed rest study and similar future studies. While current work uses a bed rest analog to develop these technologies, future work aims to prepare capabilities for future in-flight sensorimotor training and assessment to mitigate the risks of proprioception impairment after spaceflight. ACKNOWLEDGEMENTS This work was supported by the University Space Research Association Internship Program. REFERENCES [1] Mulavara A.P. et al (2018) Med Sci Sports Exerc, 50(9), 1961-1980. [2] Mulavara A.P. et al (2010) Exp Brain Res, 202(3), 649-659. [3] Macaulay T.R. et al (2021) Front. Syst. Neurosci., 15, 658-985. [4] Goel R. et al (2017) Front. Syst. Neurosci, 11. [5] Koppelmans V. et al (2013) BMC Neurology, 12.

R Bellisle↗

Countermeasures for Mitigation of Sensorimotor Decrements Following Head-Down Bed Rest

BACKGROUND Astronauts experience postflight disturbances in postural and locomotor control due to sensorimotor adaptations during spaceflight. These alterations may have adverse consequences if a rapid egress is required after landing. Although exercise is partially effective for mitigating cardiovascular and muscular deconditioning, additional countermeasures are needed to further preserve sensorimotor function for exploration missions. We have identified proprioceptive training and electrical muscle stimulation (EMS) as promising in-flight countermeasures. Since prolonged head down bed rest (HDBR) is a spaceflight analog for body unloading and causes postural and locomotor control decrements that parallel those observed after spaceflight, it can be used to facilitate the development of these countermeasures. METHODS This study will determine the effects of proprioceptive training and EMS on functional task performance and sensorimotor function following 60 days of 6° HDBR. Subjects will be randomly assigned to one of four groups: 1)an EMS arm, 2) a proprioceptive training arm, 3) an exercise plus proprioceptive training arm, and 4) a control arm. The EMS countermeasure will include daily bilateral stimulation of selected bilateral lower extremity muscles (30 minutes per session). Proprioceptive training will be performed three days per week (20 minutes per session) consisting of body-loaded postural tasks in the horizontal position on an air bearing sled. Exercise training will mimic current protocols used on the International Space Station, but treadmill aerobic exercise will be replaced with additional cycling aerobic exercise. Primary outcome measures will include pre and post HDBR functional tests that are representative of high priority exploration mission tasks and require high demand for dynamic control of postural stability. Additional measures will be used to identify the key physiological factors contributing to countermeasure benefits. Given the constrained samples size, a Bayesian modelling approach will be used to quantify the probability that there is an effect of a given magnitude. HARDWARE AND PROTOCOL DEVELOPMENT Proprioceptive countermeasure design enhancements continued as part of the Mars Campaign Office (MCO) Crew Health and Performance (CHP) Crew Health Countermeasures (CHC). The primary goals of this work were to assemble a portable version of the countermeasure system that can be used at the :envihab facility, expand the software feedback system’s capabilities, and develop an actuator loading system that mimics what could be used on the International Space Station. In addition, one major piece of exercise hardware used in previous HDBR studies, the Horizontal Squat Device, was reassembled and restored to full functionality. Human-in-the-loop pilot testing is ongoing, prior to shipping both devices to the :envihab HDBR facility. Evaluations are also underway for the best EMS device technologies and specific methods. Finally, assessment techniques are being translated for administration in the horizontal position (e.g., leg dexterity and foot sole skin sensitivity). Our current goals are to refine the countermeasure training and assessment techniques and integrate protocols across multiple modalities. RELEVANCE The deliverable from this project will be proof-of-concept sensorimotor countermeasure designs for functional task performance with full assessment of efficacy in a spaceflight analog. If one or more countermeasures are effective, they will be translated for validation with the suite of operationally implemented in-flight countermeasures. ACKNOWLEDGEMENT This work is supported by NASA’s Human Research Program Human Health Countermeasures Element and by the Canadian Space Agency (L. Bent).

T R Macaulay↗

Assessing the Relationships Between Sensorimotor Biomarkers and Post-Landing Functional Task Performance

Spaceflight drives adaptive changes in healthy individuals appropriate for sensorimotor function in a microgravity environment. These changes are maladaptive for return to earth's gravity. The inter-individual variability of sensorimotor decrements is striking, although poorly understood. The goal of this study is to identify a set of behavioral, neuroimaging and genetic measures that can be used to predict early post-flight performance on a set of sensorimotor tasks. Astronauts are recruited who previously participated in sensorimotor field tests and/or posturography soon after long-duration spaceflight. Behavioral tests include assessments of sensory dependency and adaptability. Visual dependency involves treadmill walking while viewing a moving virtual visual scene. Vestibular perceptual thresholds are measured while seated during lateral translations. Proprioception dependency is measured during one-legged stance on a horizontal air-bearing surface. Ground assessment of adaptability is performed(1) during treadmill walking with a virtual linear hallway and a moving walking surface, and (2) during multiple trials of navigating an obstacle course while wearing reversing prisms(adaptive Functional Mobility Test, aFMT). The neuroimaging tests will characterize individual differences in regional brain volumes (using Structural MRI) and white matter microstructure(using Diffusion Tensor Imaging) to serve as potential predictors of adaptive capacity. The genetic tests will utilize saliva samples to examine variations in four genes chosen because of their ability to differentiate sensorimotor adaptation ability in a normative population, including Catechol-O-methyltransferase (COMT), Dopamine Receptor D2 (DRD2), Brain-derived neurotrophic factor (BDNF) and the α2-adrenergic receptor. Twenty-seven ISS crewmembers have been tested to date, including 6 from this past year. This cohort includes 10first-time fliers, 6F, and mission durations lasting 178.6 ± 30.5 days, mean ± std. We are utilizing a combination of three post-flight functional task outcomes: tandem walk, recovery from fall and dynamic posturography. There is considerable variability among the post-flight performance outcomes for the 27participants to date. Based on a partial sample using an ordinal scale survey, 70% indicated their ability to perform functional tasks were more impacted postflight relative to inflight with 50% indicating they needed to restrict movements for a longer period postflight relative to inflight. While there is a strong association within tests obtained at different R+0 timepoints, by R+24 hr performance on one post-flight test does not necessarily correlate with performance on other post-flight tests. There are apparent relationships between individual measures and specific post-flight outcome measures, e.g., the cumulative time to complete the aFMT is significantly correlated to pre-to-post-flight changes in tandem walk (rho= 0.64, p = 0.001). Preliminary statistical analysis indicates combining biomarkers will increase predictive power and this will be explored with future analyses. Our preliminary findings underscore the importance of a comprehensive post-flight test battery including different types of tasks with varying sensory feedback. We expect that understanding the relationships between these sensorimotor biomarkers and post-flight functional task performance will improve both our understanding of the individual variability and our strategy to optimize sensorimotor countermeasures

S J Wood↗

Countermeasures for Mitigation of Sensorimotor Decrements Following Head-Down Tilt Bed Rest

BACKGROUND Astronauts experience postflight disturbances in postural and locomotor control due to sensorimotor adaptations during spaceflight. These alterations may have adverse consequences if a rapid egress is required after landing. Although exercise is partially effective for mitigating cardiovascular and muscular deconditioning, additional countermeasures are needed to further preserve sensorimotor function. Proprioception training and electrical muscle stimulation (EMS) are two promising in-flight countermeasures. Since prolonged head down tilt bed rest (HDTBR) is a spaceflight analog for body unloading and causes postural and locomotor control decrements that parallel those observed after spaceflight, it can be used to facilitate the development of these countermeasures. METHODS This study will determine the effects of proprioception training and EMS on functional task performance and sensorimotor function following 60 days of 6° HDTBR. Subjects will be randomly assigned to one of four groups: 1) an EMS arm, 2) a proprioception training arm, 3) an exercise plus proprioceptive training arm, and 4) a control arm. The EMS countermeasure will include daily bilateral stimulation of selected bilateral lower extremity muscles (30 minutes per session). Proprioception training will be performed three days per week (25 minutes per session) consisting of body-loaded postural tasks in the horizontal position on an air bearing sled. Exercise training will mimic current protocols used on the International Space Station, but treadmill aerobic exercise will be replaced with additional cycling aerobic exercise. Primary outcome measures will include pre- and post- HDTBR functional tests that require high demand for dynamic control of postural stability. Secondary measures will be used to explore key physiological changes that underlie countermeasure benefits. All HDTBR and data collection activities will be completed by the German Aerospace Center (DLR) at the :envihab facility. Given the constrained samples size, a Bayesian modelling approach will be used to quantify the probability that there is an effect of a given magnitude. HARDWARE AND PROTOCOL DEVELOPMENT Final hardware modifications and protocol developments were completed in preparation for Campaign 1, which began in September 2024. These included shipment, setup, and operator training for the transportable gravity bed, horizontal squat device, foam obstacle course, EMS devices, leg dexterity system, foot sole skin sensitivity system, and Radiofrequency Echographic Multi Spectrometry (REMS) ultrasound device. In addition, specialized protocols were developed for data collection using DLR’s equipment, including muscle morphology magnetic resonance imaging (MRI), optical coherence tomography, venous blood flow MRI and ultrasound, muscle ultrasound and impedance, and skin blood flow ultrasound. We will present early data from the first campaign, which concluded in November, 2024. These will be compared with previous data from the recent 30-day HDTBR campaigns (Spaceflight associated neuro-ocular syndrome countermeasures (SANS-CM)) conducted at DLR. RELEVANCE The deliverable from this project will be proof-of-concept sensorimotor countermeasure designs for functional task performance with full assessment of efficacy in a spaceflight analog. If one or more countermeasures are effective, they will be translated for validation with the suite of operationally implemented in-flight countermeasures.

T R Macaulay↗

Assessing the Relationships Between Sensorimotor Biomarkers and Post-Landing Functional Task Performance

Spaceflight drives adaptive changes in healthy individuals appropriate for sensorimotor function in a microgravity environment. These changes are maladaptive for return to earth's gravity. The inter-individual variability of sensorimotor decrements is striking, although poorly understood. The goal of this study was to identify a set of behavioral, neuroimaging and genetic measures that can be used to predict early post-flight performance on a set of sensorimotor tasks. Astronauts were recruited who previously participated in sensorimotor field tests and/or posturography soon after long-duration spaceflight. Behavioral tests included assessments of sensory dependency and adaptability. Visual dependency involved treadmill walking while viewing a moving virtual visual scene. Vestibular perceptual thresholds were measured while seated during lateral translations. Proprioception dependency was measured during one-legged stance on a horizontal air-bearing surface. Ground assessment of adaptability was performed (1) during treadmill walking with a virtual linear hallway and a moving walking surface, and (2) during multiple trials of navigating an obstacle course while wearing reversing prisms (adaptive Functional Mobility Test, aFMT). The neuroimaging tests characterized individual differences in regional brain volumes (using Structural MRI) and white matter microstructure (using Diffusion Tensor Imaging) to serve as potential predictors of adaptive capacity. The genetic tests utilized saliva samples to examine variations in four genes chosen because of their ability to differentiate sensorimotor adaptation ability in a normative population, including Catechol-O-methyltransferase (COMT), Dopamine Receptor D2 (DRD2), Brain-derived neurotrophic factor (BDNF) and the α2-adrenergic receptor. Thirty ISS crewmembers were recruited, including 12 first-time fliers, 6F, and mission durations lasting 185.5 ± 45.5 days, mean ± std. We utilized a combination of three post-flight functional task outcomes: tandem walk, recovery from fall and dynamic posturography. There was considerable variability among all post-flight performance outcomes. Based on an ordinal scale survey, 72% indicated their ability to perform functional tasks were more impacted postflight relative to inflight with 50% indicating they needed to restrict movements for a longer period postflight relative to inflight. While there is a strong association within tests obtained at different R+0 timepoints, by R+24 hr performance on one post-flight test does not necessarily correlate with performance on other post-flight tests. Preliminary statistical analysis indicates combining biomarkers will increase predictive power and this will be explored with future analyses. Our preliminary findings underscore the importance of a comprehensive post-flight test battery including different types of tasks with varying sensory feedback. Understanding the relationships between these sensorimotor biomarkers and post-flight functional task performance improve both our understanding of the individual variability and our strategy to optimize sensorimotor countermeasures.

biomarkers↗

Method and apparatus for implementing ultra-high stability stages with combined degrees of freedom for multiple axes of motion

A method and apparatus are provided for implementing an ultra-high stability stage with combined degrees of freedom for multiple axes of motion. The ultra-high stability stage includes a base, a driving wedge supported by the base and a following wedge supported by the driving wedge. The base and each wedge are formed of a selected stable material having predefined rigidity and low thermal expansion coefficient. Integrated air bearings, respective driving mechanics associated with each of the wedges and guiding components having selected degrees of freedom enable movement about multiple axes of motion, such as X, Y, Z translation axes, and rotation X and rotation Y axes. Another ultra-high stability stage with combined degrees of freedom for multiple axes of motion includes an intermediate wedge between the driving wedge and the following wedge to enable additional movement about a rotation X axis.

Preissner, Curt Alfred↗

A waved journal bearing concept with improved steady-state and dynamic performance

Analysis of the waved journal bearing concept featuring a waved inner bearing diameter for use with a compressible lubricant (gas) is presented. A three wave, waved journal bearing geometry is used to show the geometry of this concept. The performance of generic waved bearings having either three, four, six, or eight waves is predicted for air lubricated bearings. Steady-state performance is discussed in terms of bearing load capacity, while the dynamic performance is discussed in terms of dynamic coefficients and fluid film stability. It was found that the bearing wave amplitude has an important influence on both steady-state and dynamic performance of the waved journal bearing. For a fixed eccentricity ratio, the bearing steady-state load capacity and direct dynamic stiffness coefficient increase as the wave amplitude increases. Also, the waved bearing becomes more stable as the wave amplitude increases. In addition, increasing the number of waves reduces the waved bearing's sensitivity to the direction of the applied load relative to the wave. However, the range in which the bearing performance can be varied decreases as the number of waves increases. Therefore, both the number and the amplitude of the waves must be properly selected to optimize the waved bearing design for a specific application. It is concluded that the stiffness of an air bearing, due to the hydrodynamic effect, could be doubled and made to run stably by using a six or eight wave geometry with a wave amplitude approximately half of the bearing radial clearance.

Dimofte, Florin↗

Hydrodynamic air lubricated compliant surface bearing for an automotive gas turbine engine. 1: Journal bearing performance

A 38.1 mm (1.5 inch) diameter Hydresil Compliant Surface Air Lubricated Journal Bearing was designed and tested to obtain bearing performance characteristics at both room temperature and 315 C (600 F). Testing was performed at various speeds up to 60,000 rpm with varying loads. Rotating sensors provided an opportunity to examine the film characteristics of the compliant surface bearing. In addition to providing minimum film thickness values and profiles, many other insights into bearing operation were gained such as the influence of bearing fabrication accuracy and the influence of smooth foil deflection between the bumps.

Ruscitto, D.↗

High temperature self-lubricating coatings for air lubricated foil bearings for the automotive gas turbine engine

coating combinations were developed for compliant surface bearings and journals to be used in an automotive gas turbine engine. The coatings were able to withstand the sliding start/stops during rotor liftoff and touchdown and occasional short time, high speed rubs under representative loading of the engine. Some dozen coating variations of CdO-graphite, Cr2O3 (by sputtering) and CaF2 (plasma sprayed) were identified. The coatings were optimized and they were examined for stoichiometry, metallurgical condition, and adhesion. Sputtered Cr2O3 was most adherent when optimum parameters were used and it was applied on an annealed (soft) substrate. Metallic binders and interlayers were used to improve the ductility and the adherence.

Bhushan, B.↗

Development of surface coatings for air-lubricated, compliant journal bearings to 650 C

Surface coatings for an air-lubricated, compliant journal for an automotive gas turbine engine were tested to find those capable of withstanding temperatures of either 540 C (1000 F) or 650 C (1200 F). Also, the coatings have to be capable of surviving the start-stop sliding contact cycles prior to rotor lift-off and at touchdown. Selected coating combinations were tested in start-stop tests at 14 kPa (2 psi) loading for 2000 cycles at room and maximum temperatures. Specific coating recommendations are: Cdo and graphite on foil versus chrome carbide on journal up to 370 C (700 F); NASA PS-120 (Tribaloy 400, silver, and CaF2) on journal versus uncoated foil up to 540 C (1000 F); and chemically adherent Cr2O3 on journal and foil up to 650 C (1200 F). The chemically adherent Cr2O3 coating system was further tested successfully at 35 kPa (5 psi) loading for 2000 start-stop cycles.

Bhushan, B.↗

Hydrodynamic air lubricated compliant surface bearing for an automotive gas turbine engine. 2: Materials and coatings

Material coatings for an air-lubricated, compliant journal bearing for an automotive gas turbine engine were exposed to service test temperatures of 540 C or 650 C for 300 hours, and to 10 temperature cycles from room temperatures to the service test temperatures. Selected coatings were then put on journal and partial-arc foils and tested in start-stop cycle tests at 14 kPa (2 psi) loading for 2000 cycles. Half of the test cycles were performed at a test chamber service temperature of 540 C (1000 F) or 650 C (1200 F); the other half were performed at room temperature. Based on test results, the following combinations and their service temperature limitations are recommended: HL-800 TM (CdO and graphite) on foil versus chrome carbide on journal up to 370 C (700 F); NASA PS 120 (Tribaloy 400, silver and CaF2 on journal versus uncoated foil up to 540 C (1000 F); and Kaman DES on journal and foil up to 640 C (1200 F). Kaman DES coating system was further tested successfully at 35 kPa (5 psi) loading for 2000 start-stop cycles.

Bhushan, B.↗