Search NASA⌕ Search

SEARCH · Search NASA

Results for “Air Pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Review of Wave Energy Converter Power Take-Off Systems, Testing Practices, and Evaluation Metrics: Preprint

While the field of wave energy has been the subject of numerical simulation, scale model testing, and precommercial project testing for decades, wave energy technologies remain in the early stages of development and must continuing proving themselves as a promising modern renewable energy field. One of the difficulties that wave energy systems have been struggling to overcome is the design of highly efficient energy conversion systems that can convert the mechanical power, derived from the oscillation of wave activated bodies, into another useful product. Often the power take-off (PTO) is defined as the single unit responsible for converting mechanical power into another usable form such as electricity, pressurized fluid, compressed air, and others. The PTO, and the entire power conversion chain (PCC), is of great importance as it affects not only how efficient wave power is converted into electricity, but also contributes to the mass, size, structural dynamics, and levelized cost of energy (LCOE) of the wave energy converter (WEC). Unlike wind and solar, there is no industrial standard device, or devices, for wave energy conversion and this diversity is transferred to the PTO system. The majority of current WEC PTO systems incorporate a mechanical or hydraulic drive train, power generator, and an electrical control system. The challenge of WEC PTO designs is designing a mechanical-to-electrical component that can efficiently convert irregular, bi-directional, low frequency and low alternating velocity wave motions. While gross average power levels can be predicted in advance, the variable wave elevation input has to be converted into smooth electrical output and hence usually necessitates some type of energy storage system, such as battery storage, accumulator super capacitors, etc., or other means of compensation such as an array of devices. One of the primary challenges for wave energy converter systems is the fluctuating nature of wave resources, which require WEC components to be designed to handle loads (i.e. torques, forces, and powers) that are many times greater than the average load. This approach requires a much greater PTO capacity than the average power output and indicates a higher cost. In addition, supporting mechanical coupling and or gearing can be added to the PCC to help alleviate the difficulties with transmission and control of fluctuating large loads with low frequencies (indicative of wave forcing) into smaller loads at higher frequencies (optimum for conventional electrical machine design) can quickly increase the complexity of the PCC which could result in a greater number of failure modes and increased maintenance costs. All of the previous points demonstrate how the PTO influences WEC dynamics, reliability, performance and cost which are critical design factors. This paper further explores these topics by providing a review of the state-of-the-art PTO systems currently under development, how these novel PTO systems are tested and derisked prior to precommercial deployment, and the evaluation metrics historically used to differentiate between PTO designs and how they can be improved to support control co-design focused development of wave energy systems.

laboratory testing↗

Tar Formation and Mitigation in Pressurized Biomass and Cofired Gasification

Biomass gasification with CO2 capture has the potential to provide carbon-negative heat, power, and feedstock for sustainable hydrocarbon fuels. In a pressurized gasifier, precombustion solvent systems can capture CO2 with less energy than needed for amine-based postcombustion CO2 capture, and pressurized syngas is generally more suitable for fuel synthesis. Although precombustion capture has been used for many decades in large-scale fossil-based plants, it has not been well-demonstrated in smaller-scale biomass gasification. Precombustion solvents and product streams could be particularly impacted by tar and other organic compounds that tend to form in high concentrations during low-temperature biomass gasification. A pressurized pilot-scale gasifier was used to examine tar formation and fate when using CO2 capture with various blends of biomass and coal. The syngas was fully conditioned to remove particulate matter; capture sulfur; adjust syngas chemistry using water-gas shift; quench out moisture and condensable organics; and capture CO2. Tar concentrations were measured in the raw syngas, the product gas, and in the liquid streams over the course of several weeks. The gasifier was operated both as a high-pressure oxygen-blown system to mimic large-scale centralized gasification and at lower pressures under air-blown conditions to mimic a more likely small-scale system. A second high-temperature stage with oxidant injection was used to crack tars. The overall results showed how gasifier and CO2 capture performance change as fuel is blended between coal to biomass and what the fate of tar is through a precombustion CO2 capture system.

Strege, Josh [University of North Dakota EERC] (OR↗

Extinction of Premixed Counterflow Ammonia-Air Flames

The effects of radiative heat loss and pressure on premixed counterflow ammonia-air flames have been investigated as a function of equivalence ratio. Non-adiabatic counterflow premixed flame simulations incorporating detailed chemistry, transport and radiative heat transfer in the optically thin limit have been employed to elucidate important underlying physics and extinction characteristics. Non-adiabatic counterflow premixed computations show that the combined effects of positive flame stretch and radiative heat loss for sub-unity Lewis number mixtures lead to the extension of the lean flammability limit for ammonia-air flames, revealing a C-shaped curve near the lean flammability limit that exhibits both radiative-induced and stretch-induced extinction states. The computations compare favorably with the experimentally determined extinction stretch rate values for the stretch-induced extinction states over a wide range of equivalence ratios at different pressures up to 6 atm.

10 SYNTHETIC FUELS↗

Pressurizing Hagan and SAVY containers to 30-psig (air) to measure the release of analytical cerium oxide test powder

In response to an ESS surrounding the storage of sealed sources at TA-55, personnel from RP-SVS (Radiation Protection Services) and ORI-2 (Operational Readiness & Execution) were approached by ES-55 (Facility System Engineering) to provide technical testing of known nuclear material storage containers. Testing criteria were determined by SB-PF (Safety Basis for Plutonium Facilities). Tests were conducted in conjunction with multiple related projects at the Aerosol Sciences Laboratory (TA-03-0130-0103). An experimental system was quickly developed to deliver a pressure pulse (30-psig) that mimics a sealed source burst scenario. A series of twelve tests was conducted. Six tests were done with two different 5QT SAVY-4000 containers, where each SAVY filter-lid combination was subjected to three successive test insults. Three tests were done with a (0.375" diameter filter) 8Q.T Hagan container, and three tests with a (0.625" diameter filter) 8QT Hagan container. An unused, fresh container filter was used for each tested Hagan container, each receiving only one test insult per filter. Cerium oxide (CeO 2 ) powder was loaded (100 grams per test) into a nozzle in the tested Hagan and SAVY containers, and the nozzle was hard-plumbed to a ball valve and a pressure source. This system was installed into the Los Alamos RRFMC (Respirable Release Measurement Chamber), which is an integrated multipurpose aerosol wind tunnel that satisfies NQA-1 subpart 2.4 for R&D work. The ball valve was fitted with a mechanical linkage for operation from outside the wind tunnel. An aerodynamic particle sizer counted the particle concentrations and size distributions of released aerosol. Respirable aerosol released during the tests was measured and a correction factor for wind tunnel flowrate and internal duct deposition was applied.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Filtration Performance Results: Sierra Peaks Material No. 4

Sandia National Laboratories (SNL) assessed the filtration performance of materials from Sierra Peaks to identify alternatives which may perform similarly to materials used in FDA-approved N95 respirators. This work is meant to characterize the aerosol performance of materials to give Sierra Peaks information for them to determine if they elect to submit masks made using these materials for follow-on N95 certification testing at an accredited facility. The R&D testbed used is a large-scale filtration system designed to test commercial filter boxes. System modifications were performed to simulate, where possible, parameters defined by the National Institute for Occupational Safety and Health (NIOSH) for certification of filter materials for N95 respirators (NIOSH 2019). The system is a pull-through design. Air enters through a Laminar Flow Element (LFE) and the volumetric flow is measured based on the pressure drop across the LFE. Pressure is measured via a Pressure Transducer (PT). The air then passes through a High Efficiency Particulate Air (HEPA) filter to purge the air of ambient airborne particulates. Test aerosol is injected into the flow shortly after and mixing is induced via a coarse mesh. The airflow is allowed to fully develop prior to arriving at the test section. The aerosol then passes through the test material mounted in a box in the test section. Pressure drop across the test article is measured and aerosol sampling probes measure the aerosol concentrations upstream and downstream of the sample. The air passes through a second HEPA filter prior to being exhausted to ambient by a blower. A Topas aerosol generator is used to produce the test aerosol from Sodium Chloride (NaC1) dissolved in deionized (DI) water. Generated aerosol passes through a heated mixing chamber and a desiccant dryer to produce nanosized solid-state particulates. A dilution loop allows for the aerosol concentration to be regulated. The aerosol sampling probes upstream and downstream of the test section are aligned with the flow path. These are ducted directly to the aerosol sizing and counting instruments. A Laser Aerosol Spectrometer (LAS) was used for data collection in the original configuration of the system and was also used for initial testing in this project. Because the lower measurement range for the LAS is 90 nanometers (nm), the LAS was switched out for a more complicated Scanning Mobility Particle Sizer (SMPS) spectrometer system. The SMPS is comprised of an Electrostatic Classifier (EC), Differential Mobility Analyzer (DMA), and a Condensation Particle Counter (CPC). This enabled data collection at 75 nm, the particle size called out in the NIOSH guidelines.

36 MATERIALS SCIENCE↗

Nitrogen evolution, NO X formation and reduction in pressurized oxy coal combustion

Oxy-combustion is one of the most prominent solutions for reducing CO 2 emissions from coal-fired power plants using carbon-capture-and-utilization technology. However, when compared to air combustion at atmospheric pressure, oxy-combustion is very expensive, owing to the significant efficiency penalties associated with air separation, flue gas recirculation (FGR), treatment, compression, and storage or transit of CO 2 . In comparison, pressurized oxy-combustion (POC) is more efficient as it recovers a significant amount of heat energy from the flue gas moistures. Nevertheless, CO 2 derived from pressurized oxy coal combustion has impurities, e.g., acid gases (NO X and SO X ) that can corrode the plant equipment, transport lines as well as deteriorating effect on the environment. Fortunately, in pressurized combustion systems, both NO X and SO X can be scrubbed by a single-column direct contact cooler (DCC), but this requires a minimum ratio of NO X to SO X at the inlet to be efficiently removed. Therefore, NOx is one of the important hindering parameters in commercializing the pressurized oxy-combustion. Although NOx evolution during oxy-coal combustion has been explored extensively at 1 atm, higher pressure studies are rare. Much still needs to be done to better understand the NO X mechanism and the effects of different parameters on NO X emissions under these conditions. Here, this paper reviews the published literature on nitrogen evolution, NO X formation and reduction in pressurized oxy-coal combustion. At higher pressures, the NO X from fuel-bound nitrogen is generated through volatiles, tar and char, all of which are discussed. Where literature is not available, the effect of pressure on NOx evolution in different stages of coal combustion is predicted through CHEMKIN simulation. Homogeneous and heterogeneous pathways of NO X formation and their destruction in pressurized oxy-coal combustion are evaluated. Additionally, the effect of pressure on a few mature and commercialized NOx abatement methods is explored. In the last, the future perspective and recommendation are given. This review will aid in the provision of basic knowledge about NOx evolution and control in pressurized fuel combustion, as well as the identification of new research areas to pursue.

01 COAL, LIGNITE, AND PEAT↗

Experimental Investigation of Nanosecond and Subnanosecond Pulsed DBD in Atmospheric Air: Fast Imaging and Spectroscopy

Dielectric barrier discharge (DBD), as an easy and simple way of generation of non-thermal plasma, has found a number of applications in variuos fields. However, development of a homogeneous, or uniform, DBD that would operate at atmospheric pressure conditions in atmospheric air, would open a number of new applications in various fields from thin film coatings to plasma medicine. Unfortunately, at atmospheric pressure, a uniform DBD can be easily transformed into a filamentary dielectric DBD; therefore some serious issues arise, such as gas heating due to strong discharges in the random microdischarge channel and non-uniform energy distribution, which adversely affect applications. These issues traditionally are solved by the use of an appropriate working gas composition, an alternating current driving frequency, lowering of gas pressure, etc. The transitions between discharge modes in the same experimental conditions have been thoroughly investigated in nitrogen, rare gases and their mixtures with air and other gases. In many cases (for example, in plasma medicine), these methods, especially those related to gas composition and pressure, may not be applied in a convenient manner. Recent advances in pulsed power technology permitted application of much faster voltage rise times (including the subnanosecond range) and short (few nanoseconds) pulses, and revealed that uniform DBD can, in fact, be generated in atmospheric air. Such discharges are in the great interest for many applications, however to date there still little understanding of the mechanisms of their operation and characteristics. Currently, there is no adequate model of the uniform dielectric barrier discharge development in atmospheric air. Although extensive studies have been performed on understanding of the nature of the pulsed DBD uniformity, until now there is still little understanding of the mechanism of the DBD transition from the filamentary mode to uniform mode. One of the reasons for this is that development of streamers, and later – filaments, occurs on the sub-nanosecond and nanosecond time scales, and therefore requires imaging and other diagnostic techniques with corresponding speed of registration. Recently developed technologies allow such studies. Here we demonstrate that DBD uniformity strongly depends on applied electric field in the discharge gap. More specifically, the discharge uniformity may be achieved in the case when two conditions are satisfied: (1) stong overvoltage in the discharge gap (provided by fast rise times), when anode-directed streamers are formed, and (2) short pulse duration that prevents discharge overheating due to rising conductivity (current) which leads to formation of filaments. We show that by controlling the applied (global) electric field in ns-pulsed DBD, it is possible to control the uniformity of the discharge. In addition, this offers better control of the discharge chemistry due to local changes of electric fields and therefore electron energy distribution function.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fiber Optic Temperature Sensor Using Dual Air- Filled Fabry-Pérot Cavities With Variable Pressure

We present an approach for high temperature measurement using a pair of fiber-optic Fabry–Pérot (FP) cavities filled with gas of identical but variable pressure. One of the FPs (reference FP) is placed in the cold zone with a known temperature. The temperature of the measuring FP can be deduced by the spectral fringe shift vs. pressure of the two FPs. This method does not require measurement of the pressure or the knowledge of the optical properties of the gas. The use of gas as the sensing material and the measurement mechanism also implies long-term stability and eliminates the cross-sensitivity to strain. We fabricated the sensors and tested them for measuring temperature up to 800 °C. Here, the sensor shows good linearity in the range. Long-term test conducted at 800 °C exhibited the stability of the sensor with fluctuations of ≤0.3% over a duration exceeding 100 hours.

42 ENGINEERING↗

Detailed chemistry modeling of rotating detonations with dilute n -heptane sprays and preheated air

Utilization of liquid fuels is crucial to enabling commercialization of rotating detonation engines (RDE) in the near future. In this study, Eulerian-Lagrangian simulations are conducted for rotating detonative combustion with dilute n-heptane sprays and preheated air. Two-dimensional flattened configuration is used and a skeletal chemical mechanism with 44 species and 112 elementary reactions for n-heptane combustion is adopted. The flow structure, droplet distribution, and thermochemical parameters in the refill zone are first analyzed. It is shown that the mixture in the refill zone is heterogeneous, including evaporating droplets, vapor, and air. When the total temperature is below 950 K, the average equivalence ratio increases with the total temperature. When it is higher than 950 K, the average equivalence ratio is almost constant. Subsequently, the chemical explosive mode analysis is applied to identify the controlling reactions and dominant combustion modes in the fuel refill zone and reaction fronts. Results demonstrate that the initiation reaction (R104: n-C 7 H 16 + O 2 2-C 7 H 15 + HO 2 ) and low-temperature reaction (R107: RO 2 R'O 2 H) are dominant in the upstream and downstream of the refill zone, respectively. The intermediate species from low-temperature chemistry, R'O 2 H, is found to be important for the chemical explosive mode in the undetonated mixture. The influence of species diffusion and dispersed droplets is further analyzed. Results show that vapor autoignition facilitated by droplet evaporation occurs in the refill zone. Finally, the effects of the air total temperature on the detonation propagation speed and RDE propulsion performance are investigated. Further, it is found that the detonation propagation speed and specific impulse increase with air total temperature. The total pressure ratio first increases and then decreases as the air total temperature increases. Moreover, when the total temperature of the preheated air is above 1,300 K, the effects of low-temperature chemistry are negligible.

33 ADVANCED PROPULSION SYSTEMS↗

Dynamic optical spectroscopy and pyrometry of static targets under optical and x-ray laser heating at the European XFEL

Experiments accessing extreme conditions at x-ray free electron lasers (XFELs) involve rapidly evolving conditions of temperature. Here, we report time-resolved, direct measurements of temperature using spectral streaked optical pyrometry of x-ray and optical laser-heated states at the High Energy Density instrument of the European XFEL. This collection of typical experiments, coupled with numerical models, outlines the reliability, precision, and meaning of time dependent temperature measurements using optical emission at XFEL sources. Dynamic temperatures above 1500 K are measured continuously from spectrally- and temporally-resolved thermal emission at 450–850 nm, with time resolution down to 10–100 ns for 1–200 μs streak camera windows, using single shot and integrated modes. Targets include zero-pressure foils free-standing in air and in vacuo, and high-pressure samples compressed in diamond anvil cell multi-layer targets. Radiation sources used are 20-fs hard x-ray laser pulses at 17.8 keV, in single pulses or 2.26 MHz pulse trains of up to 30 pulses, and 250-ns infrared laser single pulses. A range of further possibilities for optical measurements of visible light in x-ray laser experiments using streak optical spectroscopy are also explored, including for the study of x-ray induced optical fluorescence, which often appears as background in thermal radiation measurements. We establish several scenarios where combined emissions from multiple sources are observed and discuss their interpretation. Challenges posed by using x-ray lasers as non-invasive probes of the sample state are addressed.

47 OTHER INSTRUMENTATION↗

Experimental study of airpath electrification in an opposed-piston two stroke (OP2S) engine architecture

The opposed-piston two stroke (OP2S) engine shows potential as an alternative engine architecture to the conventional four stroke engine due to its high-power density, thermal efficiency, and versatile airpath management system. Since the pistons of a two-stroke engine do not pump the air into and out of the cylinder like in a four-stroke engine, the selection of the air induction devices and airpath actuators becomes critical to optimize engine performance. Both the pumping losses and the in-cylinder combustion process can be affected by the scavenging process in a two-stroke engine. Therefore, this study compares two different airpath configurations for the same family of OP2S engines and investigates performance metrics like scavenging control, pumping work, net indicated and brake efficiencies, and engine-out emissions associated with each airpath. Data was collected on a 3.2 L, two-cylinder OP2S engine with an electrically assisted turbocharger (EAT) and a 4.9 L displacement, three-cylinder engine with a variable geometry turbocharger (VGT) and a supercharger. The experiments consisted of speed and load sweeps for both engines at the same operating conditions to compare scavenge control in both architectures. For the three-cylinder layout, the SE sweep range was much higher, and the intake pressure could be independently varied with air flowrate, thus providing more flexibility for scavenging control. The supercharger and the VGT usage was optimized based on its efficiency map and thus, this layout had lower pumping losses compared to the EAT. The two-cylinder engine had a higher overall SE as compared to the three-cylinder engine, but the intake pressure and air flowrate could not be decoupled, leading to over scavenging and increased short circuiting of fresh charge into the exhaust.

Bhatt, Ankur [Clemson University, Clemson, SC, USA↗

Apparatus and method for manufacturing an air maintenance tire

Apparatus and method for manufacturing an air maintenance tire includes an air pumping tube assembly station constructing an air pumping tube sub-assembly, a tire preparation station for forming passageways in the tire to accept an outlet device of the air pumping tube sub-assembly, an air pumping tube sub-assembly installation station and a pressure regulator installation station. The air pumping tube sub-assembly inserts into an elongate tire groove opening, facilitated by groove-spreading apparatus.

42 ENGINEERING↗

Proton beam position measurement in air using a BPM

A Beam Position Monitor (BPM) is potentially useful to measure the position and phase of the beam in air in a non-destructive way. An air-gap BPM in experiments, such as beam-induced radioactive waste management and dynamic radiography applications, where a so-called air gap is needed, can be utilized to measure the beam position and phase. In this study, a stripline BPM was used in the air-gap of an 800 MeV proton beam transport line. The downstream end of the primary beamline exit window was made of a thin aluminum plate and allowed the beam to travel 1.2 m in ambient air before re-entering into a vacuum drift section. Such a configuration was arranged to examine the BPM effectiveness in atmospheric temperature and pressure where ionization of air occurs. In this study, a high energy (800 MeV), high current (0.6 A beam peak current/pulse) proton beam of 5 mm radius was transported in the air. The beam position relative to the axis was measured by detecting the signature of the beam in a nanosecond scale. This nanosecond scale detection ability was useful to identify other signals such as plasma effects. The BPM signals were processed at a frequency of 201 MHz; thus, one gets a stronger response in a stripline pattern as it was used in this study instead of a dot-type BPM. Experimental data show that the BPM works well in air, but ionization of air or plasma formation could not be measured over the BPM signal. The design, construction, and performance of a BPM in air environment are presented.

43 PARTICLE ACCELERATORS↗

Design and Modeling of a Demonstration-scale ORC Cycle for the Liquid Air Combined Cycle

Energy storage is becoming an increasing focus for the future energy markets. One potential hybrid system for ling duration energy storage is the Liquid Air Combined Cycle (LACC). The LACC utilizes excess renewable energy to liquefy and store air during the charge cycle. During its discharge cycle, the system uses the exhaust heat from a conventional combustion turbine and an ORC bottoming cycle to vaporize and superheat the stored air that has been pressurized, which is subsequently expanded to atmosphere through a turbine. During the development of the cycle, it has been identified that the main technologies to advance the cycle are the ORC bottoming cycle machinery and the coupled operation between the liquified air subsystem and the ORC subsystem. This paper presents modeling and simulation of the LACC that involves ORC conditions that fall outside the operating regime of more common applications. Due to the low temperatures of liquified air, the ORC system operates on the order of -70°C for the pump, and the turbine has a pressure ratio around 40. The conceptual design of a demonstration system has been developed that focuses on these challenges in order to advance the overall system.

Pryor, Owen↗

A modular chemo-selective oxygen production unit to deliver oxygen for advanced combustion systems

Commercial oxygen generation technologies deploy either cryogenic air separation or vacuum pressure swing adsorption (VPSA). These technologies can provide nearly pure oxygen but are only economically viable at oxygen production rates of 100-7,000 tonnes/day. The state-of-theart cryogenic air separation plants are impending the theoretical limits of thermodynamic efficiency but cannot be scaled down to cater future needs. Therefore, there is great incentive to develop a new approach for oxygen separation that can accommodate the upcoming demands. Our proposed research approach address to find novel methodologies to provide energy efficient modular O 2 on demand systems for modular gasification and other applications. Small scale modular systems for O 2 production offer certain benefits including enhanced energy efficiency, reduced operating costs and flexibility to tailor location specific needs. Our hypothesis is that a small modular system could be engineered using solvent-based capture and thermal release of oxygen, to enable “oxygen on demand” for any combustion-related technology.

42 ENGINEERING↗

Energy Savings With Acceptable Indoor Air Quality Through Improved Airflow Control in Residential Retrofits

The Partnership for Advanced Residential Retrofit (PARR) has been a U.S. Department of Energy (DOE) Building America team since 2009, with a primary focus on upgrading the performance of existing buildings to reduce energy loads. In this project, PARR’s work explored the integration of airflow-focused measures in residential retrofit homes with the goal to maximize energy savings while ensuring acceptable indoor air quality (IAQ) using a systems approach to controlling four contributing air streams: • Building air leakage (natural, uncontrolled infiltration), • Forced-air distribution system static pressure and airflow rate, • Distribution system duct leakage, and • Mechanical ventilation. This project addressed airflows in houses, their combined impact on energy use and IAQ, and the comparative effects of typical insulation and air sealing practices versus integrated system-level retrofits. Additionally, practical considerations for contractors taking either approach were addressed. Finally, the effects of supply ventilation and exhaust ventilation on IAQ were compared in occupied homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air Return Strategies and Airborne SARS-CoV-2

Dedicated ducted air return per zone for heating, ventilating, and air-conditioning (HVAC) systems is sometimes claimed to be a superior technique over plenum return strategy from the viewpoint of exposure reduction to airborne pathogens. While both the return strategies have advantages, there is limited evidence in the literature as to which strategy is superior merely from a standpoint of building vulnerability to airborne contaminants. We performed multizonal airborne contaminant dispersion modelling using CONTAM to simulate the overall building vulnerability to airborne SARS-CoV-2 aerosols when released in an office building and evaluated the two air return strategies. Results showed that for ducted returns, maintaining negative pressure in the release zone coupled with 100% outdoor air supply can greatly reduce overall building vulnerability. However, for a building maintained under a slight positive pressure and a recirculated air percentage as low as 31%, ducted returns do not necessarily outperform plenum returns in terms of overall building vulnerability to airborne pathogens. Building-specific details and factors that are not easily represented with multizone modelling are important, making general preferential statements for either strategy difficult to make. Insights from this study can guide new construction and retrofits of buildings both during and after the COVID-19 pandemic with the aim of safe re-occupancy of buildings while keeping the buildings resilient against potential future epidemics spread by airborne agents.

Shrestha, Prateek↗

Effects of hydrogen partial pressure on crack initiation and growth rate in vintage X52 steel

There is an increasing interest in ensuring compatibility of existing natural gas infrastructure with conveyance of hydrogen, especially for vintage (pre-1970s) pipeline steels. While hydrogen is known to affect the fatigue and fracture resistance of these materials, there is a lack of data on its effects on crack initiation at low hydrogen partial pressure. To address this gap, the current work presents a series of fatigue tests on vintage API Grade X52 steel in pure nitrogen, air and gaseous hydrogen at partial pressures of 1 and 207 bar. Circumferential notch tension (CNT) specimens with direct current potential difference (DCPD) measurements are used to get S–N curves for crack initiation and failure, and compact tension (CT) tests to assess crack growth rates. Results indicate that air accelerates crack initiation, low hydrogen partial pressure affects the crack growth rate, and higher pressures have the largest impact on both. Surprisingly, crack initiation is faster in air than at 1 bar hydrogen partial pressure. The CNT tests also reveal that the orientation of the banded microstructure has no effect on the crack initiation site, but it influences its growth behavior. Moreover, fractography shows that hydrogen also promotes instances of quasi-cleavage and intergranular fracture, linked to embrittlement of the material. Here, these results demonstrate that, while hydrogen may impact the entirety of the fatigue process, its effects on the early stages of damage accumulation become relevant only at larger pressures. More comprehensive studies of crack initiation in hydrogen atmospheres will be critical to future codes and standards for hydrogen infrastructure.

Circumferential notch tension↗