Search NASA⌕ Search

SEARCH · Search NASA

Results for “Analytical Method Development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Model Development for Multi-Component Fuel Vaporization and Flash Boiling

The objectives of this project are to improve the multi-component fuel droplet and film vaporization models used in internal combustion engine simulation, and to develop a comprehensive model to predict the characteristics of multi-component flash boiling spray. This work explores two approaches to fuel composition treatment for modeling multi-component fuel vaporization: one based on discretization and surrogates, and the other based on continuous thermodynamic distribution of fuel properties. The experimental data collected for model validation are done under three fuel form factors: droplet, spray, and thin film. The study on sprays also include experimentation under non-flash and flash boiling conditions, a phenomenon that enhances fuel vaporization. The main goals of this work are: Design and develop a multi-component fuel droplet and wall film vaporization model using both discrete and continuous thermodynamics methods. Design and develop an analytical model for multi-component flash boiling. Integrate the multi-component droplet and film model into multi-dimensional engine calculations to predict the fuel vaporization process under engine operation condition. Conduct multi-component droplet and fuel film vaporization experiments in a non-combusting chamber to verify the proposed vaporization models. Characterize flash boiling phenomena of multi-component fuel sprays by optical and laser diagnostic techniques. This report will detail the experimental setup and the numerical basis for developing a model to achieve the main goals listed above. Key features of observed multi-component fuel vaporization will be summarized at the end of each experimental sections, and corresponding model performance evaluation will be presented at the end of each model development section.

33 ADVANCED PROPULSION SYSTEMS↗

Testing of the Defense Waste Processing Facility Cold Chemical Dissolution Method in Sludge Batch 10 Qualification

For each sludge batch that is processed in the Defense Waste Processing Facility (DWPF), the Savannah River National Laboratory (SRNL) tests the applicability of the digestion methods used by the DWPF Laboratory for elemental analysis of Sludge Receipt and Adjustment Tank (SRAT) Receipt samples and SRAT Product process control samples. DWPF SRAT samples are typically dissolved using a method referred to as the DWPF Cold Chemical or Cold Chem Method (CC), (see DWPF Procedure SW4-15.201- 2.1).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nondestructive Assay Technical Infrastructure Program Mission and Vision

The Nondestructive Assay Program (NDAP) mission and vision is achieved by identifying and accomplishing a set of programmatic goals that correspond with eight broad technical program elements. The NDAP was created as a result of Defense Nuclear Facility Safety Board Recommendation 2007-1, entitled “Safety-Related In Situ Nondestructive Assay of Radioactive Materials,” which emphasized the need to improve in situ measurements of radioactive material at US Department of Energy (DOE) defense nuclear facilities. An NDAP five-year plan will define tasks to accomplish specific goals identified in the NDAP mission and vision. This mission and vision is applicable for eight technical program elements: Hardware/Software Development, Algorithm Development and Nuclear Data, Uncertainty Quantification, Nuclear Materials, Staffing, Personnel, And Training, Data Management, Requirement and Standards, and Information Preservation and Dissemination. An additional program element is technical support, which provides daily execution management support for the NDAP, site scope, and deliverable tracking via site task managers, along with technical advisement and support from the technical support group. The NDAP mission and vision provides attributes with specific goals for each program element, and some goals benefit multiple program elements. The goals and attributes defined herein are implemented via an NDAP five-year execution plan that defines site work scope, budget, and deliverables, all of which are updated annually. The NDAP is designed to benefit nondestructive assay (NDA) needs to support DOE nuclear criticality safety programs, ensuring that NDA technology is sufficiently capable of guaranteeing the safety of those who handle, store, process, or transport fissionable materials in the complex. Especially important for the NDAP is to maximize capabilities to identify, characterize, and manage in situ fissile material deposits in process equipment to ensure nuclear criticality safety at processing facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Synchrotron Radiation Research and Analysis of the Particulate Matter in Deep Ice Cores: An Overview of the Technical Challenges

Airborne dust extracted from deep ice core perforations can provide chemical and mineralogical insight into the history of the climate and atmospheric conditions, with unrivalled temporal resolution, time span and richness of information. The availability of material for research and the natural complexity of the particulate, however, pose significant challenges to analytical methods. We present the developments undertaken to optimize the experimental techniques, materials and protocols for synchrotron radiation-based analysis, in particular for the acquisition of combined Synchrotron Radiation X-Ray Fluorescence and X-ray Absorption Spectroscopy data.

Cibin, Giannantonio↗

Biomass Compositional Analysis Laboratory (Fact Sheet)

At the Biomass Compositional Analysis Laboratory, NREL scientists have more than 20 years of experience supporting the biomass conversion industry. They develop, refine, and validate analytical methods to determine the chemical composition of biomass samples before, during, and after conversion processing. These high-quality compositional analysis data are used to determine feedstock compositions as well as mass balances and product yields from conversion processes.

09 BIOMASS FUELS↗

Analysis of Ionic Mercury Species in SRR Samples Measured by SRNL and Eurofins FGS

Savannah River Remediation (SRR) requested the development of mercury speciation capabilities at the Savannah River National Laboratory (SRNL) to support the Liquid Waste Operations at SRS. As part of that method development, SRR requested that SRNL Analytical Development (AD) compare their results with those obtained from their outside contract laboratory, Eurofins Frontier Global Sciences (FGS). This document reports on this method development work performed at SRNL as well as the comparative analyses conducted between the two laboratories. Development, optimization, and validation were undertaken at SRNL to produce a method for the species-specific analysis of ionic mercury. This method was developed as a secondary step to an existing method, L16.1-ADS-1579 Purgeable Mercury Cold Vapor Atomic Fluorescence Spectrophotometry. As such, much of the development and validation were performed in service of development of L16.1-ADS-1579. Six samples, representing two consecutive quarterly Tank 50 batches, were tested for ionic mercury by SRNL-AD and Eurofins FGS. The mean values reported by each lab for ionic mercury differed by less than one standard deviation, therefore the values reported by both labs were considered to be in agreement. SRNL-AD reported values for the six samples that differed by -5.56 mean percent, relative to Eurofins FGS. Together with comparable quality control data reported by each laboratory, these data represent a high level of agreement among both laboratories. With a viable method for ionic mercury that matches the data quality provided by outside commercial laboratories, SRNL-AD has demonstrated competency in measuring methylmercury, ethylmercury, total mercury, soluble & particulate mercury, purgeable mercury, and ionic mercury species in a variety of radioactive tank samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Evaluation of Actinide Reactivity with CO 2 , O 2 , and O 2 /He Gases using Inductively Coupled Plasma Tandem Mass Spectrometry: Application to Simultaneous Measurement of 241 Am/ 241 Pu Ratios in Unseparated Complex Matrices

Accurate actinide measurements are critical within the field of nuclear science. Traditional methods for actinide quantification require time-consuming sample processing prior to analysis. There is a need for rapid analytical techniques that still maintain a high degree of accuracy. In this work, actinide reactivity was assessed for multiple oxygen-containing reaction gases using quadrupole inductively coupled plasma tandem mass spectrometry (Q-ICP-MS/MS) to evaluate actinide analysis in complex sample matrices without analyte-matrix separation. A novel method was developed to measure 241 Am/ 241 Pu in complex sample matrices using O 2 /He reaction gas with no matrix removal or analyte pre-concentration. This inline method reduces matrix-derived polyatomic interferences that complicate traditional ICP-MS analyses by mass-shifting to 241 Am 16 O + and 241 Pu 16 O 2 + , allowing Am and Pu to be mass separated for simultaneous analysis. While mass shifting is efficient, a small portion of Am + (<1.3%) and Pu + (<1.4%) react to from AmO 2 + and PuO + , respectively. Therefore, a mass balance approach was used, in combination with reactivity determined from 242 Pu and 243 Am standard solutions, to correct for residual 241 PuO + and 241 AmO 2 + . The method was validated by measuring 241 Am/ 241 Pu in Pu isotope standards CRM-136 and CRM-137 (separated in March/April 1970 and February 2022, respectively) in both neat solutions and complex matrices containing diluted soil (NIST SRM 2711a, >1000 µg·g -1 ). Method detection limits of 15.9 and 9.6 fg·g -1 were determined for 241 Am and 241 Pu, respectively, and 241 Am/ 241 Pu ratios were measured with accuracies within <3.5%. In conclusion, this work presents the first direct analysis of 241 Am/ 241 Pu in unseparated complex matrices, advancing capabilities for rapid actinide measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Targeted Metabolomics of the Phenylpropanoid Pathway in Arabidopsis thaliana using Reversed Phase Liquid Chromatography Coupled with Tandem Mass Spectrometry: Measuring Lignin Precursors by LC-MS

The phenylpropanoid pathway is a source of a diverse group of compounds derived from phenylalanine, many of which are involved in lignin biosynthesis and serve as precursors for the production of valuable compounds, such as coumarins, flavonoids, and lignans. Consequently, recent efforts have been invested in mechanistically understanding monolignol biosynthesis, making the quantification of these metabolites vital. To develop an improved and comprehensive analytical method for (i) extensively profiling, and (ii) accurately quantifiying intermediates of the monolignol biosynthetic network, using Arabidopsis thaliana as a model system. A liquid chromatography-tandem mass spectrometry with electrospray ionization was developed to quantify phenylpropanoid metabolites in Arabidopsis wildtype and cinnamoyl CoA reductase1 (CCR1) deficient lines (ccr1). Vortexing at high temperatures (65°C) enhanced release of phenylpropanoids, specifically the more hydrophobic compounds. A pH of 5.3 and ammonium acetate buffer concentration of 2.5 mM resulted in an optimal analyte response across standards. Ion suppression was estimated using standard spike recovery studies for accurate quantitation. The optimized method was used to profile Arabidopsis wildtype and ccr1 stems. An increase in hydroxycinnamic acid derivatives and a decrease in the hydroxycinnamyl aldehydes and alcohols in ccr1 lines, supports a shift of flux from lignin synthesis to other secondary metabolites and phenylpropanoid derivatives. Compared to existing targeted profiling techniques, our method is capable of quantifying a wider range of intermediates (15 out of 22 in WT Arabidopsis stems) at low in vivo concentrations (~50 pmol/g-FW for certain compounds), while requiring minimal sample preparation.

09 BIOMASS FUELS↗

Methylmercury and Ethylmercury Analytical Performance in SRR Samples Measured by SRNL and Eurofins Frontier Global Sciences

Existing models and simulants of tank disposition media at the Savannah River Site (SRS) have presumed the presence of high concentrations of inorganic mercury. However, quarterly Tank 50 analyses have shown that mercury is present as organomercurial species at concentrations that may present challenges to its remediation and disposition and may challenge the Waste Acceptance Criteria (WAC) for Saltstone. Todate, methylmercury analyses for Savannah River Remediation (SRR) have been performed at an off-site laboratory by Eurofins Frontier Global Sciences (FGS) in Bothell, WA. Savannah River Remediation requested the development of methylmercury and ethylmercury determination capabilities at the Savannah River National Laboratory (SRNL) to support the Liquid Waste Operations at SRS. As part of that method development, SRR requested that SRNL Analytical Development (AD) compare their results with those obtained from their outside contract laboratory, Eurofins FGS. This document reports on this method development work as well as the comparative analyses conducted between the two laboratories. A series of optimization and validation experiments has been performed at SRNL, which has resulted in the development of on-site methylmercury and ethylmercury speciation capabilities using purge and trap (P&T) gas chromatography (GC) coupled with thermal desorption (TD) cold vapor – atomic fluorescence spectroscopy (CVAFS). Speciation has been achieved for both species, with a methylmercury method reporting limit (MRL) value of 1.13 pg and an overall uncertainty (1σ) of 5.1%. An ethylmercury MRL of 11.5 pg and an overall uncertainty (1σ) of 4.8% were obtained. These analytical parameters compare favorably with Eurofins FGS, which demonstrates uncertainties (1σ) for methylmercury and ethylmercury of 13% and 9.1%, respectively. Results obtained by SRNL from the routine analysis of Tanks 21, 40, 50, and 51 samples have provided statistically indistinguishable results compared with Eurofins FGS. Based upon the work performed by SRNL-AD and the data currently available, the following recommendations can be made: Further work should be performed to determine a “best practices” for sample holding time prior to analysis (both preserved and non-preserved samples), as well as any detrimental effects sample age may have on data quality. Analysis of ethylmercury is only recommended for tank samples that are reasonably expected to have significant quantities of ethylmercury, such as from the DWPF SMECT. Trace levels of ethylmercury in the presence of large quantities of methylmercury can be difficult or impossible to quantify. SRNL-AD development of methods for total mercury, purgeable mercury (which includes Hg(0) and dimethylmercury), inorganic mercury (Hg(I) and Hg(II)), dissolved mercury, and particulate mercury are underway and will be reported upon separately.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Deep eutectic solvents as green and sustainable diluents in headspace gas chromatography for the determination of trace level genotoxic impurities in pharmaceuticals

Genotoxic impurities (GTIs) are potential carcinogens that need to be controlled down to ppm or lower concentration levels in pharmaceuticals under strict regulations. The static headspace gas chromatography (HS-GC) coupled with electron capture detection (ECD) is an effective approach to monitor halogenated and nitroaromatic genotoxins. Deep eutectic solvents (DESs) possess tunable physico-chemical properties and low vapor pressure for HS-GC methods. In this study, zwitterionic and non-ionic DESs have been used for the first time to develop and validate a sensitive analytical method for the analysis of 24 genotoxins at sub-ppm concentrations. Compared to non-ionic diluents, zwitterionic DESs produced exceptional analytical performance and the betaine: 7 (1,4- butane diol) DES outperformed the betaine: 5 (1,4-butane diol) DES. Limits of detection (LOD) down to the 5-ppb concentration level were achieved in DESs. Wide linear ranges spanning over 5 orders of magnitude (0.005–100 µg g –1 ) were obtained for most analytes with exceptional sensitivities and high precision. The method accuracy and precision were validated using 3 commercially available drug substances and excellent recoveries were obtained. Finally, this study broadens the applicability of HS-GC in the determination of less volatile GTIs by establishing DESs as viable diluent substitutes for organic solvents in routine pharmaceutical analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MO-DE-207A-07: Filtered Iterative Reconstruction (FIR) Via Proximal Forward-Backward Splitting: A Synergy of Analytical and Iterative Reconstruction Method for CT

Purpose: This work is to develop a general framework, namely filtered iterative reconstruction (FIR) method, to incorporate analytical reconstruction (AR) method into iterative reconstruction (IR) method, for enhanced CT image quality. Methods: FIR is formulated as a combination of filtered data fidelity and sparsity regularization, and then solved by proximal forward-backward splitting (PFBS) algorithm. As a result, the image reconstruction decouples data fidelity and image regularization with a two-step iterative scheme, during which an AR-projection step updates the filtered data fidelity term, while a denoising solver updates the sparsity regularization term. During the AR-projection step, the image is projected to the data domain to form the data residual, and then reconstructed by certain AR to a residual image which is in turn weighted together with previous image iterate to form next image iterate. Since the eigenvalues of AR-projection operator are close to the unity, PFBS based FIR has a fast convergence. Results: The proposed FIR method is validated in the setting of circular cone-beam CT with AR being FDK and total-variation sparsity regularization, and has improved image quality from both AR and IR. For example, AIR has improved visual assessment and quantitative measurement in terms of both contrast and resolution, and reduced axial and half-fan artifacts. Conclusion: FIR is proposed to incorporate AR into IR, with an efficient image reconstruction algorithm based on PFBS. The CBCT results suggest that FIR synergizes AR and IR with improved image quality and reduced axial and half-fan artifacts. The authors was partially supported by the NSFC (#11405105), the 973 Program (#2015CB856000), and the Shanghai Pujiang Talent Program (#14PJ1404500).

60 APPLIED LIFE SCIENCES↗

A Unified Analytical Method to Quantify Three Types of Fast Frequency Response from Inverter-Based Resources

With more inverter-based resources (IBRs), our power systems have lower frequency nadirs following N-1 contingencies, and undesired under-frequency load shedding (UFLS) can occur. To address this challenge, IBRs can be programmed to provide at least three types of fast frequency response (FFR), e.g., step response, proportional response (P/f droop response), and derivative response (synthetic inertia). However, these heterogeneous FFR challenge the study of power system frequency dynamics. Thus, this paper develops an analytical frequency nadir prediction method that allows for the consideration of all three potential forms of FFR provided by IBRs. The proposed method provides fast and accurate frequency nadir estimation after N-1 generation tripping contingencies. Our method is grounded on the closed-form solution for the frequency nadir, which is solved from the second-order system frequency response model considering the governor dynamics and three types of FFR. The simulation results in the IEEE 39-bus system with different types of FFR demonstrate that the proposed method provides an accurate and fast prediction of the frequency nadir under various disturbances.

fast frequency response↗

Bridging Equipment Reliability Data and Robust Decisions in a Plant Operation Context

In order to reduce operation and maintenance (O&M) costs, nuclear power plants (NPPs) are moving from corrective and periodic maintenance to predictive maintenance strategies. Such transition requires changes on the data that needs to be retrieved and on the type of decision processes to be employed. Advanced monitoring and data analysis technologies are essential to support predictive strategies. They can in fact provide precise information about health of a component, track its degradation trends, and provide information of its expected failure time. With such information, maintenance operations for a component can be performed right before its expected failure time. This dynamic context of O&M operations requires new methods to analyze data, propagate component health information from the component to the system level, and optimize plant resources. In this respect, the risk informed asset management (RIAM) project has been tasked to develop and test this new class of methods into a risk analytics toolset. This toolset consists of data analytics tools coupled with reliability methods designed to manage plant assets and performances in a predictive maintenance context. This report shows the latest improvements on such development and the initial testing of our methods on the three main research areas that the RIAM project is focusing on. These areas are the following: equipment reliability data analytics, system reliability modeling, and plant resources optimization methods. We show how the methods developed in these areas can support predictive maintenance strategies by: 1) analyzing equipment reliability data (either in numeric and textual form), 2) assessing component and system health through an innovative margin-based reliability approach, and 3) identifying the most critical components and set optimal maintenance schedule based on plant economic and operational constraints.

97 MATHEMATICS AND COMPUTING↗

Electromagnetic pulse excitation of finite- and infinitely-long lossy conductors over a lossy ground plane

This study details a model for the response of a finite- or an infinite-length wire interacting with a conducting ground to an electromagnetic pulse excitation. We develop a frequency–domain method based on transmission line theory that we name ATLOG – Analytic Transmission Line Over Ground. This method is developed as an alternative to full-wave methods, as it delivers a fast and reliable solution. It allows for the treatment of finite or infinite lossy, coated wires, and lossy grounds. The cases of wire above ground, as well as resting on the ground and buried beneath the ground are treated. The reported method is general and the time response of the induced current is obtained using an inverse Fourier transform of the current in the frequency domain. The focus is on the characteristics and propagation of the transmission line mode. Comparisons with full-wave simulations strengthen the validity of the proposed method.

25 ENERGY STORAGE↗

BETO 2021 Peer Review - Analytical Development & Support WBS 2.5.1.101

The objective of the Analytical Development and Support (ADS) Project is to produce and maintain the critical analytical methods and tools that enable evaluation of emerging biofuels R&D at NREL and in the broader biofuels research community. Our project is divided into two tasks: one task to develop novel analytical techniques and improve existing methods and one task to maintain existing analytical capabilities at NREL and provide outreach to the wider community. The ADS Project is world-recognized for our Laboratory Analytical Procedures (LAPS) which provide detailed procedures for compositional analysis of biomass and have been adopted as the de facto standards within the biofuels community largely due to the transparency of the methods and the high reputation of NREL's research. Our dialog with stakeholders allows us to provide robust, precise, accurate, and publicly available analytical procedures for better valuation of scientific tools such as our recent accomplishment in developing a cellulose assay to support the EPA and industry in calculation of converted cellulose during starch ethanol production. We continue to develop analytical capabilities to support BETO's directives to research cost advantaged fuels such as animal wastes and novel bioproducts like 2,3-Butane-diol.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SARS-CoV-2 wastewater variant surveillance: pandemic response leveraging FDA’s GenomeTrakr network

ABSTRACT Wastewater surveillance has emerged as a crucial public health tool for population-level pathogen surveillance. Supported by funding from the American Rescue Plan Act of 2021, the FDA‘s genomic epidemiology program, GenomeTrakr, was leveraged to sequence SARS-CoV-2 from wastewater sites across the United States. This initiative required the evaluation, optimization, development, and publication of new methods and analytical tools spanning sample collection through variant analyses. Version-controlled protocols for each step of the process were developed and published on protocols.io. A custom data analysis tool and a publicly accessible dashboard were built to facilitate real-time visualization of the collected data, focusing on the relative abundance of SARS-CoV-2 variants and sub-lineages across different samples and sites throughout the project. From September 2021 through June 2023, a total of 3,389 wastewater samples were collected, with 2,517 undergoing sequencing and submission to NCBI under the umbrella BioProject,PRJNA757291. Sequence data were released with explicit quality control (QC) tags on all sequence records, communicating our confidence in the quality of data. Variant analysis revealed wide circulation of Delta in the fall of 2021 and captured the sweep of Omicron and subsequent diversification of this lineage through the end of the sampling period. This project successfully achieved two important goals for the FDA’s GenomeTrakr program: first, contributing timely genomic data for the SARS-CoV-2 pandemic response, and second, establishing both capacity and best practices for culture-independent, population-level environmental surveillance for other pathogens of interest to the FDA. IMPORTANCE This paper serves two primary objectives. First, it summarizes the genomic and contextual data collected during a Covid-19 pandemic response project, which utilized the FDA’s laboratory network, traditionally employed for sequencing foodborne pathogens, for sequencing SARS-CoV-2 from wastewater samples. Second, it outlines best practices for gathering and organizing population-level next generation sequencing (NGS) data collected for culture-free, surveillance of pathogens sourced from environmental samples.

Microbiology↗

Novel epoxy-silica nanoparticles to develop non-enzymatic colorimetric probe for analytical immuno/bioassays

We have developed a novel method to develop epoxy silica nanoparticles (EfSiNP) in a single pot. High surface coverage of epoxy functional groups between 150 and 57000 molecules per particles (~10 13 –10 16 molecules/mL of 200 nm EfSiNPs) was achieved for different preparation conditions. We then created a red colored probe by conjugating Fuchsin dye to the epoxy functionalities of EfSINPs. Anti-mouse IgG was co-immobilized with Fuchsin and their ratios were optimized for achieving optimum ratios by testing those in functional assays. Dye to antibody ratios were in good negative correlation with a coefficient of -1.00 measured at a confidence level of over 99%. We employed the developed non-enzymatic colorimetric immunonanoprobe for detecting mouse IgG in a direct immunoassay format. We achieved a sensitivity of 427 pg/mL with the assay.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-477: An Efficient Dose Correction Algorithm Accounting for Tissue Heterogeneities in LDR Brachytherapy

Purpose: Seed brachytherapy is currently used for adjuvant radiotherapy of early stage prostate and breast cancer patients. The current standard for calculation of dose surrounding the brachytherapy seeds is based on American Association of Physicist in Medicine Task Group No. 43 (TG-43 formalism) which generates the dose in homogeneous water medium. Recently, AAPM Task Group No. 186 emphasized the importance of accounting for tissue heterogeneities. This can be done using Monte Carlo (MC) methods, but it requires knowing the source structure and tissue atomic composition accurately. In this work we describe an efficient analytical dose inhomogeneity correction algorithm implemented using MIM Symphony treatment planning platform to calculate dose distributions in heterogeneous media. Methods: An Inhomogeneity Correction Factor (ICF) is introduced as the ratio of absorbed dose in tissue to that in water medium. ICF is a function of tissue properties and independent of source structure. The ICF is extracted using CT images and the absorbed dose in tissue can then be calculated by multiplying the dose as calculated by the TG-43 formalism times ICF. To evaluate the methodology, we compared our results with Monte Carlo simulations as well as experiments in phantoms with known density and atomic compositions. Results: The dose distributions obtained through applying ICF to TG-43 protocol agreed very well with those of Monte Carlo simulations as well as experiments in all phantoms. In all cases, the mean relative error was reduced by at least 50% when ICF correction factor was applied to the TG-43 protocol. Conclusion: We have developed a new analytical dose calculation method which enables personalized dose calculations in heterogeneous media. The advantages over stochastic methods are computational efficiency and the ease of integration into clinical setting as detailed source structure and tissue segmentation are not needed. University of Toronto, Natural Sciences and Engineering Research Council of Canada.

60 APPLIED LIFE SCIENCES↗