Scattering-type scanning near-field optical microscopy with Akiyama piezo-probes

Recent developments of the scattering-type scanning near-field optical microscope at cryogenic temperatures (cryogenic s-SNOM or cryo-SNOM) have led to many breakthroughs in the studies of low energy excitations in quantum materials. However, the simultaneous demands on vibration isolation, low base temperature, precise nano-positioning, and optical access make the construction of a cryo-SNOM a daunting task. Adding to the overhead space required for a cryo-SNOM is the atomic force microscopy control, which predominantly utilizes a laser-based detection scheme for determining the cantilever tapping motion. In this work, we provide an alternative and straightforward route to performing s-SNOM using metal-coated Akiyama probes, where the cantilever tapping motion is detected through a piezoelectric signal. We show that the Akiyama-based cryo-SNOM attains high spatial resolution, good near-field contrast, and is able to perform imaging with a significantly more compact system compared to other cryo-SNOM implementations. Our results firmly establish the potential of s-SNOM based on self-sensing piezo-probes, which can easily accommodate far-infrared wavelengths and high magnetic fields in the future.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interferometric control of parametrically amplified waveforms

Using atomic coherence, four-wave-mixing radiation is generated between the excited states of a ladder-type configuration in rubidium atomic vapor. By using all-optical phase control between the two frequency-swept driving beams connecting the two lower levels, the generated signal is phase modulated across its bandwidth. When homodyned with a local oscillator, such phase control looks promising for applications including waveform shaping and high-resolution metrology. Experimental observations of signal line shape symmetrization, linewidth narrowing, and bandwidth switching are demonstrated.

74 ATOMIC AND MOLECULAR PHYSICS↗

Quantum superpositions of crystalline structures

A procedure is discussed for creating coherent superpositions of motional states of ion strings. The motional states are across the structural transition linear-zigzag, and their coherent superposition is achieved by means of spin-dependent forces, such that a coherent superposition of the electronic states of one ion evolves into an entangled state between the chain's internal and external degrees of freedom. It is shown that the creation of such an entangled state can be revealed by performing Ramsey interferometry with one ion of the chain.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Early results from a prototype VLBI clock monitoring system

Four sets of experiments were conducted to measure the relative epoch offsets between atomic clocks in California, Australia, and Spain by means of very long baseline interferometry (VLBI). The experiments were conducted using an incomplete R & D VLBI system with a number of inherent limitations. The results indicate that the measurement objective of epoch offset to 10 nanoseconds will be met. Tables show the measured offset, the residual to fit, and the square root Allan variance. Graphs show the rate change and the rate reset.

Yunck, T. P.↗

Set-up of a high-resolution 300 mK atomic force microscope in an ultra-high vacuum compatible {sup 3}He/10 T cryostat

The design of an atomic force microscope with an all-fiber interferometric detection scheme capable of atomic resolution at about 500 mK is presented. The microscope body is connected to a small pumped {sup 3}He reservoir with a base temperature of about 300 mK. The bakeable insert with the cooling stage can be moved from its measurement position inside the bore of a superconducting 10 T magnet into an ultra-high vacuum chamber, where the tip and sample can be exchanged in situ. Moreover, single atoms or molecules can be evaporated onto a cold substrate located inside the microscope. Two side chambers are equipped with standard surface preparation and surface analysis tools. The performance of the microscope at low temperatures is demonstrated by resolving single Co atoms on Mn/W(110) and by showing atomic resolution on NaCl(001).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of the conformational ensemble of the TAR RNA by X-ray scattering interferometry

The conformational ensembles of structured RNA’s are crucial for biological function, but they remain difficult to elucidate experimentally. We demonstrate with HIV-1 TAR RNA that X-ray scattering interferometry (XSI) can be used to determine RNA conformational ensembles. X-ray scattering interferometry (XSI) is based on site-specifically labeling RNA with pairs of heavy atom probes, and precisely measuring the distribution of inter-probe distances that arise from a heterogeneous mixture of RNA solution structures. We show that the XSI-based model of the TAR RNA ensemble closely resembles an independent model derived from NMR-RDC data. Further, we show how the TAR RNA ensemble changes shape at different salt concentrations. Finally, we demonstrate that a single hybrid model of the TAR RNA ensemble simultaneously fits both the XSI and NMR-RDC data set and show that XSI can be combined with NMRRDC to further improve the quality of the determined ensemble. The results suggest that XSI-RNA will be a powerful approach for characterizing the solution conformational ensembles of RNAs and RNA-protein complexes under diverse solution conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Interferometric weak value deflections: Quantum and classical treatments

We derive the weak value deflection given in an article by Dixon et al.[P. B. Dixon et al. Phys. Rev. Lett. 102 173601 (2009)] both quantum mechanically and classically, including diffraction effects. This article is meant to cover some of the mathematical details omitted in that article owing to space constraints.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new experiment to test parity symmetry in cold chiral molecules using vibrational spectroscopy

We present a brief review of our progress towards measuring parity violation in heavy-metal chiral complexes using mid-IR Ramsey interferometry. We discuss our progress addressing the main challenges, including the development of buffer-gas sources of slow, cold polyatomic molecules, and the frequency-stabilisation of quantum cascade lasers calibrated using primary frequency standards. We report investigations on achiral test species of which promising chiral derivatives have been synthesised. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development and applications of optical interferometric micrometrology in the angstrom and subangstrom range

The recent development of the scanning electron tunneling microscope and the atomic force microscope requires absolute standards for measurements in the angstrom and subangstrom range. Optical interferometry with lasers and multiple mode laser resonances can provide absolute measurements as the laser wavelengths are very accurately known. A key feature of such measurements is the use of piezoelectric crystals as translators of the highest accuracy for very small disturbances. However, the dimensional changes of these crystals resulting from electrical potential changes depend on many variables, among them the method of mounting, so that accurate calibrations are necessary. Starting from advances in optical metrology made by physicists trying to find gravity waves, advances which led to measurements down to 10 to the -5 A, the author designed and built a much simpler system for the angstrom range. The major limiting factors were mechanical vibrations, air currents, thermal changes and laser instabilities.

Lauer, James L.↗

Time Evolution of the Electron and Ar* Metastable Atom Densities in Pulsed Plasmas

Metastable and electron densities of pulsed argon plasma containing nano-sized particles were measured by the means of Laser Absorption Spectroscopy and Microwave Interferometry, respectively. Laser Induced Fluorescence was probing the Ar* metastable axial distribution during one dust growing cycle. The experimental results of the dust-free and dusty plasma afterglow were compared to the results obtained by a global model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-averaged adiabatic ring potential for ultracold atoms

We report the experimental realization of a versatile ring trap for ultracold atoms. The ring geometry is created by the time-averaged adiabatic potential resulting from the application of an oscillating magnetic bias field to a rf-dressed quadrupole trap. Lifetimes for a Bose-Einstein condensate in the ring exceed 11s and the ring radius was continuously varied from 50 {mu}m to 262 {mu}m. An efficient method of loading the ring from a conventional time-averaged orbiting potential trap is presented together with a rotation scheme which introduces angular momentum into the system. The ring presents an opportunity to study the superfluid properties of a condensate in a multiply connected geometry and also has applications for matter-wave interferometry.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantitative x-ray differential-interference-contrast microscopy with independently adjustable bias and shear

We present a quantitative x-ray phase imaging method that can be readily implemented on existing x-ray microscopy facilities. This technique utilizes Fresnel zone plates both as imaging optical elements for magnification and as second-order grating structures for phase-shifting interferometry. By making high-resolution quantitative x-ray phase information widely available, we expect this work to have significant impact on nanoscale biological and material studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

E(B – V), N(H I), and N(H{sub 2})

We consider the structure of the N(H I)-E(B – V) relationship when H I is measured in the 21 cm radio line and E(B – V) is defined by far-IR dust-derived measures. We derive reddening-dependent corrections to N(H I) based on interferometric absorption measurements over the past 30 yr that follow a single power-law relationship ∫τ(H I)dv=14.07 km s{sup −1} E(B – V){sup 1.074} at 0.02 ≲ E(B – V) ≲ 3 mag. Corrections to 21 cm line-derived H I column densities are too small to have had any effect on the ratio N(H I)/E(B – V) = 8.3 × 10{sup 21} cm{sup –2} mag{sup –1} we derived at 0.015 ≲ E(B – V) ≲ 0.075 mag and |b| ≥ 20°; they are also too small to explain the break in the slope of the N(H I)-E(B – V) relation at E(B – V) ≳ 0.1 mag that we demonstrated around the Galaxy at |b|≥20°. The latter must therefore be attributed to the onset of H{sub 2} formation and we show that models of H{sub 2} formation in a low-density diffuse molecular gas can readily explain the inflected N (H I) – E(B – V) relationship. Below |b| = 20° N(H I)/E(B – V) measured at 0.015 ≲ E(B – V) ≲ 0.075 mag increases steadily down to |b| = 8° where sightlines with small E(B – V) no longer occur. By contrast, the ratio N(H I)/E(B – V) measured over all E(B – V) declines to N(H I)/E(B – V) = 5-6 × 10{sup 21} cm{sup –2} mag{sup –1} at |b| ≲ 30°, perhaps providing an explanation of the difference between our results and the gas/reddening ratios measured previously using stellar spectra.

79 ASTRONOMY AND ASTROPHYSICS↗

Scalable Bose-Einstein-condensate Sagnac interferometer in a linear trap

We demonstrate a two-dimensional atom interferometer in a harmonic magnetic waveguide using a Bose-Einstein condensate. Such an interferometer could measure rotation using the Sagnac effect. Compared to free space interferometers, larger interactions times and enclosed areas can in principle be achieved, since the atoms are not in free fall. In this implementation, we induce the atoms to oscillate along one direction by displacing the trap center. We then split and recombine the atoms along an orthogonal direction using an off-resonant optical standing wave. We enclose a maximum effective area of 0.1 mm{sup 2} limited by fluctuations in the initial velocity and by the coherence time of the interferometer. We argue that this arrangement is scalable to enclose larger areas by increasing the coherence time and then making repeated loops.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Limits on amplification by Aharonov-Albert-Vaidman weak measurement

We analyze the amplification by the Aharonov-Albert-Vaidman weak quantum measurement on a Sagnac interferometer [Dixon et al., Phys. Rev. Lett. 102, 173601 (2009)] up to all orders of the coupling strength between the measured system and the measuring device. The amplifier transforms a small tilt of a mirror into a large transverse displacement of the laser beam. The conventional analysis has shown that the measured value is proportional to the weak value, so that the amplification can be made arbitrarily large in the cost of decreasing output laser intensity. It is shown that the measured displacement and the amplification factor are in fact not proportional to the weak value and rather vanish in the limit of infinitesimal output intensity. We derive the optimal overlap of the pre- and postselected states with which the amplification become maximum. We also show that the nonlinear effects begin to arise in the performed experiments so that any improvements in the experiment, typically with an amplification greater than 100, should require the nonlinear theory in translating the observed value to the original displacement.

47 OTHER INSTRUMENTATION↗

Requirements for probing chiral Casimir-Polder forces in a molecular Talbot-Lau interferometer

We theoretically investigate the influence of chiral Casimir-Polder (CP) forces in Talbot-Lau interferometry, based on three nanomechanical gratings. We study scenarios where the second grating is either directly written into a chiral material or where the nanomask is coated with chiral substances. We show requirements for probing enantiospecific effects in matter-wave interferometry in the transmission signal and the interference fringe visibility, which depend on the de Broglie wavelength and the molecular chirality. The proposed setup is particularly sensitive to CP forces in the nonretarded regime where chiral effects can be comparable in magnitude to their electric and magnetic counterparts. While the first and third gratings do not change the phase of the matter wave, applying a coating of chiral substances to them enhances the instrument's chiral selectivity. Published by the American Physical Society 2024

74 ATOMIC AND MOLECULAR PHYSICS↗

Probing Light Atoms at Subnanometer Resolution: Realization of Scanning Transmission Electron Microscope Holography

Atomic resolution imaging of light elements in electron-transparent materials has long been a challenge. Biomolecular materials, for example, are rapidly altered by incident electrons. We demonstrate a scanning transmission electron microscopy (STEM) technique, called STEM holography, capable of efficient structural analysis of beam-sensitive nanomaterials. STEM holography measures the absolute phase and amplitude of electrons passed through a specimen via interference with a vacuum reference wave. We use an amplitude-dividing nanofabricated grating to prepare multiple beams focused at the sample. We configure the postspecimen microscope imaging system to overlap the beams, forming an interference pattern. We record and analyze the pattern at each 2D-raster-scan-position, reconstructing the complex object wave. As a demonstration, we image gold nanoparticles on an amorphous carbon substrate at 2.4 Å resolution. In conclusion STEM holography offers higher contrast of the carbon while maintaining gold atomic lattice resolution compared to high angle annular dark field STEM.

4D-STEM↗

Titanium alloy response sensitivity to variations in spectral reconstructions of National Ignition Facility xenon line-emission x-ray sources

Thermomechanical shock experiments on the National Ignition Facility (NIF) aim to study high strain rate dynamic material response. In such experiments, the NIF laser is used to generate high fluence x-ray emission sources, which irradiate material samples of interest. Under sufficiently high x-ray energy deposition, thermomechanical impulses are generated in the materials. While it is known that the characteristics of x-ray generated impulses vary as a function of incident x-ray spectra, it remains unclear how spectral assumptions and uncertainties in NIF spectral reconstructions affect our interpretation of impulsive loading. Here, in this paper, we simulate the response of a standard titanium alloy baseline sample to synthetic analytically derived and measured NIF xenon line-emission x-ray sources with a radiation hydrodynamics code. We vary the source spectral characteristics based on different source reconstruction techniques to understand the resulting variation in baseline sample response and compare the simulated response with experimental results. We find that the response is highly sensitive to assumptions made about the spectral contents and that knowledge of spectral uncertainties bounds our understanding of the resulting material response. The results of this effort help to extend our ability to use baseline material samples to extract quantitative properties from x-ray experiments on the NIF.

Alloys↗