Method of investigation of vibroacoustic characteristics of centrifugal pumps
A method for acoustical diagnostics of pumps is described which consists of taking sonograms of the pump, by means of an audio spectrograph. In distinction from usual analyzers, the spectrograph makes it possible to obtain a three-dimensional image of the signal being analyzed, in which its frequency-amplitude characteristics developed over time are depicted with a resolving power of 0.004 sec. As an example, a sonogram of an electrically driven pump, in the 40-4000 Hz frequency range, is presented. The amplitude ratios are determined on the sonogram by the contrast of individual contours, with an accuracy of 6 db.