Search NASA⌕ Search

SEARCH · Search NASA

Results for “BASE HEATING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Seasonal performance evaluation of zero-superheat active refrigerant charge control for variable-speed heat pumps

Heat pumps account for a significant portion of electricity consumption in buildings, making their energy efficiency a critical area of research. Control optimization is recognized as an effective approach for enhancing the efficiency of building HVAC systems. Specifically, since the efficiency of heat pumps increases with reduced superheat and the optimal refrigerant charge level varies with operating conditions, zero-superheat active charge control is a promising strategy to maximize the system’s COP. However, due to its complexity, this control strategy remains in the research phase and has only been tested under limited operating conditions. This paper proposes a methodology to evaluate the seasonal performance improvement of zero-superheat active charge control across a full range of heating conditions in buildings. The methodology includes the development of an optimal controller that utilizes an accumulator to store excess refrigerant and manages the active charge level at zero superheat through subcooling control, as well as the creation of a detailed physics-based heat pump model. Targeted a 3-ton variable-speed heat pump with R410A refrigerant, we selected ten U.S. cities representing different climate regions for seasonal performance evaluation. Our simulations indicate that, depending on the climate conditions, the optimal control strategy could achieve energy savings ranging from 5.8 % to 8.0 % over the entire heating season. These results suggest that zero-superheat active charge control, combined with coordinated compressor and fan speeds, could substantially improve the energy efficiency of heat pump systems while maintaining the required heating capacity.

Guo, Fangzhou↗

An Optimization-Based HVAC Load and PV Disaggregation Methodology With Contextual Supervision

Here, this letter presents an optimization-based Heating, Ventilation, and Air Conditioning (HVAC) and PV disaggregation approach. This letter builds on the previous works of authors, which discuss HVAC disaggregation strategy for aggregated levels without requiring sub-metered information. This letter expands on previous works to discuss optimization-based HVAC disaggregation by varying PV penetration scenarios with joint disaggregation of HVAC load and PV.

Analytics↗

Radiation from advanced solid rocket motor plumes

The overall objective of this study was to develop an understanding of solid rocket motor (SRM) plumes in sufficient detail to accurately explain the majority of plume radiation test data. Improved flowfield and radiation analysis codes were developed to accurately and efficiently account for all the factors which effect radiation heating from rocket plumes. These codes were verified by comparing predicted plume behavior with measured NASA/MSFC ASRM test data. Upon conducting a thorough review of the current state-of-the-art of SRM plume flowfield and radiation prediction methodology and the pertinent data base, the following analyses were developed for future design use. The NOZZRAD code was developed for preliminary base heating design and Al2O3 particle optical property data evaluation using a generalized two-flux solution to the radiative transfer equation. The IDARAD code was developed for rapid evaluation of plume radiation effects using the spherical harmonics method of differential approximation to the radiative transfer equation. The FDNS CFD code with fully coupled Euler-Lagrange particle tracking was validated by comparison to predictions made with the industry standard RAMP code for SRM nozzle flowfield analysis. The FDNS code provides the ability to analyze not only rocket nozzle flow, but also axisymmetric and three-dimensional plume flowfields with state-of-the-art CFD methodology. Procedures for conducting meaningful thermo-vision camera studies were developed.

Farmer, Richard C.↗

Numerical Study of Base Pressure Characteristic Curve for a Four-Engine Clustered Nozzle Configuration

Excessive base heating has been a problem for many launch vehicles. For certain designs such as the direct dump of turbine exhaust in the nozzle section and at the nozzle lip of the Space Transportation Systems Engine (STME), the potential burning of the turbine exhaust in the base region has caused tremendous concern. Two conventional approaches have been considered for predicting the base environment: (1) empirical approach, and (2) experimental approach. The empirical approach uses a combination of data correlations and semi-theoretical calculations. It works best for linear problems, simple physics and geometry. However, it is highly suspicious when complex geometry and flow physics are involved, especially when the subject is out of historical database. The experimental approach is often used to establish database for engineering analysis. However, it is qualitative at best for base flow problems. Other criticisms include the inability to simulate forebody boundary layer correctly, the interference effect from tunnel walls, and the inability to scale all pertinent parameters. Furthermore, there is a contention that the information extrapolated from subscale tests with combustion is not conservative. One potential alternative to the conventional methods is computational fluid dynamics (CFD), which has none of the above restrictions and is becoming more feasible due to maturing algorithms and advancing computer technology. It provides more details of the flowfield and is only limited by computer resources. However, it has its share of criticisms as a predictive tool for base environment. One major concern is that CFD has not been extensively tested for base flow problems. It is therefore imperative that CFD be assessed and benchmarked satisfactorily for base flows. In this study, the turbulent base flowfield of a experimental investigation for a four-engine clustered nozzle is numerically benchmarked using a pressure based CFD method. Since the cold air was the medium, accurate prediction of the base pressure distributions at high altitudes is the primary goal. Other factors which may influence the numerical results such as the effects of grid density, turbulence model, differencing scheme, and boundary conditions are also being addressed. Preliminary results of the computed base pressure agreed reasonably well with that of the measurement. Basic base flow features such as the reverse jet, wall jet, recompression shock, and static pressure field in plane of impingement have been captured.

Wang, Ten-See↗

Nuclear Thermal Energy Storage Configurations for Industrial Combined Heat and Power Supply: Conceptual Study and Engineering Designs

The industries examined in this report primarily rely on moderate-temperature heat provided by gas- or coal-fired boilers and combined heat and power (CHP) plants, delivered through standard process steam systems. High-temperature energy demands are often industry-specific and typically exceed the capabilities of high-temperature gas-cooled reactors (HTGRs). While it is technically feasible to replace process steam from fossil-based heat sources with nuclear energy, certain industries, such as methanol production and pulp and paper, face technoeconomic challenges in integrating nuclear energy without major changes or a technological shift. This is mainly due to the limited external energy demand remaining after the use of internal byproducts, waste heat recovery, and simple efficiency improvements. Achieving full decarbonization of these processes with nuclear energy would require significant technological advancements, involving experimental technology and substantial investments, making widespread adoption in existing industrial plants unlikely in the near term. This study reviews TES options in the context of enabling a flexible CHP supply while maintaining a steady nuclear heat input. Heat storage systems that interface between the reactor primary fluid and the CHP system offer superior performance and flexibility. Specifically, steam extraction downstream of the reheater with a two-tank molten-salt TES appears as the best solution regarding thermodynamic system benefits and system drawbacks. Using selected system configurations, a conceptual design of an industrial energy park was developed for industries with varying energy demands, such as steel production plants utilizing electric arc furnaces (EAFs) and chemical plants, as well as for those with constant energy demands, like petroleum refineries. This design highlights the capabilities of TES and explores its potential business cases. The study also conceptually develops the potential for integrating additional energy sources with nuclear systems through the implementation of TES. The potential of the HTGR-TES-CHP system was also evaluated considering key uncertainties such as industrial demand profiles, external grid access availability, and eligible tax credit levels, using the Holistic Energy Resource Optimization Network. Sensitivity of net present value to these uncertainties was analyzed to determine the optimal number of nuclear reactors (and CHP systems) and the suitable TES capacity. The results were interpreted from a decision-maker’s perspective, focusing on three key areas: deployment strategy (oversized units vs. undersized units with TES support), industrial process characteristics (thermal-intensive single profiles vs. electricity-intensive combined profiles), and operational goals (maximizing profits vs. minimizing natural gas (NG) consumption or external grid dependence). The optimization results indicate that the HTGR-TES-CHP system significantly reduces reliance on NG boilers for individual industrial processes by 9-60% (in NG capacity factor), with an average reduction of 38%, compared to standalone NG boiler operation case (Business As Usual [BAU]). For combined industrial processes, the reduction ranges from 37-77%, with an average of 60%. Additionally, the system greatly reduces dependence on external grids. In meeting industrial electrical demands, a 33-100% self-sufficient internal electricity supply is achieved for single industrial process, with an average of 74%, compared to the BAU scenario, where 100% of electricity is imported. For combined processes, 35-100% of internal electricity demands are met by the reactor, with an average of 73%. At last, the relative NG price levels at which the proposed HTGR-TES-CHP system can cost-effectively enter the market currently dominated by existing NG boilers were estimated. For a moderate HTGR CAPEX level ($\$$2500/kWth, $\$$6329/kWe), the analysis suggests that NG prices must be 2.5 to 7 times higher than HTGR variable operating and maintenance costs for single industrial process, and 5.5 to 9.5 times higher for a combined process scenario. Tax credit modeling shows that the Investment Tax Credit significantly reduces the price threshold needed to break even, making the system competitive with NG boilers in certain cases.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Latent Heating Algorithm

Rainfall production is a fundamental process within the Earth's hydrological cycle because it represents both a principal forcing term in surface water budgets, and its energetics corollary, latent heating, is the principal source of atmospheric diabatic heating. Latent heat release itself is a consequence of phase changes between the vapor, liquid, and frozen states of water. The properties of the vertical distribution of latent heat release modulate large-scale meridional and zonal circulations within the Tropics - as well as modify the energetic efficiencies of mid-latitude weather systems. This paper highlights the retrieval of latent heat release from satellite measurements generated by the Tropical Rainfall Measuring Mission (TRMM) and Global Precipitation Measurement (GPM) Mission satellite observatory, which were launched in November 1997 and February 2014, respectively. Both TRMM and GPM measurements have been providing an accurate four-dimensional account of rainfall over the global Tropics and mid-latitudes: information that can be used to estimate the space-time structure of latent heating.Two sets of latent heating (LH) retrieval algorithm methodologies (Goddard Convective-Stratiform Heating or CSH, and Japan's Spectral Latent Heating or SLH) have been developed to estimate latent heating based on rain rate profile retrievals obtained from TRMM and GPM measurements. The differences and similarities between the CSH and SLH algorithm designs will be presented. The presentation then will provide the results of LH structures derived from the TRMM and GPM. At the end of presentation, the further research on latent heating retrieval from satellites will be discussed.

Tao, Wei-Kuo↗

Development of a Deep-Penetrating, Compact Geothermal Heat Flow System for Robotic Lunar Geophysical Missions

Geothermal heat flow measurements are a high priority for the future lunar geophysical network missions recommended by the latest Decadal Survey of the National Academy. Geothermal heat flow is obtained as a product of two separate measurements of geothermal gradient and thermal conductivity of the regolith/soil interval penetrated by the instrument. The Apollo 15 and 17 astronauts deployed their heat flow probes down to 1.4-m and 2.3-m depths, respectively, using a rotary-percussive drill. However, recent studies show that the heat flow instrument for a lunar mission should be capable of excavating a ~3-m deep hole to avoid the effect of potential long-term changes of the surface thermal environment. For a future robotic geophysical mission, a system that utilizes a rotary/percussive drill would far exceed the limited payload and power capacities of the lander/rover. Therefore, we are currently developing a more compact heat flow system that is capable of 3-m penetration. Because the grains of lunar regolith are cohesive and densely packed, the previously proposed lightweight, internal hammering systems (the so-called moles ) are not likely to achieve the desired deep penetration. The excavation system for our new heat flow instrumentation utilizes a stem which winds out of a pneumatically driven reel and pushes its conical tip into the regolith. Simultaneously, gas jets, emitted from the cone tip, loosen and blow away the soil. Lab tests have demonstrated that this proboscis system has much greater excavation capability than a mole-based heat flow system, while it weighs about the same. Thermal sensors are attached along the stem and at the tip of the penetrating cone. Thermal conductivity is measured at the cone tip with a short (1- to 1.5-cm long) needle sensor containing a resistance temperature detector (RTD) and a heater wire. When it is inserted into the soil, the heater is activated. Thermal conductivity of the soil is obtained from the rate of temperature increase during the heating. By stopping during the excavation, it is possible to measure thermal conductivities at different depths. The gas jets are turned off when the penetrating cone reaches the target depth. Then, the stem pushes the needle sensor into the undisturbed soil at the bottom of the hole and carries out a thermal conductivity measurement. When the measurement is complete, the system resumes excavation. RTDs, placed along the stem at short (approx 30 cm) intervals, will monitor long-term temperature stability of the subsurface. Temperature in the shallow subsurface would fluctuate with the diurnal, annual, and precession cycles of the Moon. These thermal waves penetrate to different depths into the regolith. Longterm monitoring of the subsurface temperature would allow us to accurately delineate these cyclic signals and separate them from the signal associated with the outward flow of the Moon s endogenic heat. Further, temperature toward bottom of the 3-m hole should be fairly stable after the heat generated during the excavation dissipates into the surrounding soil. The geothermal gradient may be determined reliably from temperature measurements at the RTDs near the bottom. In order to minimize the heat conduction along the stem from affecting the geothermal gradient measurements, we plan to use low-conductive materials for the stem and develop a mechanism to achieve close coupling between the RTDs and the wall of the excavated hole.

Nagihara, Seiichi↗

Space-borne power conversion into a microwave beam and its impact on the environment of the upper atmosphere

The possible effect of microwave beams transmitted from Solar Power Satellites on the ionosphere has been studied theoretically. Particular attention is given to microwave-beam-heating of the F and D layers and theoretical predictions of such ionospheric modifications are used to determine resulting effects on the transmission efficiency of communication and navigation systems. It is recommended that a three-pronged technology and demonstration program be established to study microwave effects. The program would include theoretical studies, ground-based heating experiments, and an orbital experimental program for phase control of the microwave power transmission system.

Maynard, O. E.↗

Electrical and Thermal Load Impacts of Three District Heating and Cooling Designs for an Existing Community in Washington, DC

District energy systems that provide building heating and cooling are a promising option to provide low-cost, energy efficient heating and cooling solutions for communities. As some buildings move to electrified heating designs, there may be significant increases in electric grid demand, particularly in the winter. District energy systems may be able to help reduce these high electrical demands on the electric grid, while also providing decreased overall energy consumption with an increased flexibility in electrical energy usage. To evaluate and compare district options for district-based heating and cooling, an existing neighborhood of Washington, DC consisting of 35 existing buildings was selected as a case study. This study models and compares a fourth generation (4G) district heating and cooling systems that provide hot and chilled water from a central plant directly to each prosumer and a fifth generation (5G) district heating and cooling systems that provide near-ambient water via geothermal boreholes to interface with an energy transfer station with a heat pump at each prosumer. These district systems are compared against a baseline of the non-connected buildings with their self-contained and current HVAC systems. The neighborhood was selected as a good candidate for a district system for its diversity of loads (mix of different commercial and property types) and the availability of building characteristics. URBANopt District Energy Systems (DES) was used to model the buildings and create initial Modelica models for the district systems. Finally, the DES models were tuned and simulated in Dymola, and the outputs were post-processed for verification and to calculate the electrical and thermal grid impact metrics. This is the first documentation of this workflow and its complete analysis. The three designed systems are compared via their grid metrics including: total energy consumption, electrical demand peak loads, daily peak-to-valley ratios, and system ramping. A detailed discussion is provided about how each system impacts and interacts with the electric grid.

15 GEOTHERMAL ENERGY↗

Thermal Integration of Advanced Nuclear Reactors with a Reference Refinery, Methanol Synthesis, and a Wood Pulp Plant (Rev.1)

The present report is intended to provide process flow diagrams (PFDs) and energy and mass balance data sheets for a U.S. industrial sector subset with which nuclear heat and power could be integrated—a subset that includes the oil refining, methanol and pulp and paper industries. Coupling options for integrating nuclear energy into these industries are quantitatively outlined for reference systems, and future work will extend this analysis in greater detail. Opportunities for integrating small modular nuclear reactors (SMNRs) were investigated for each of the industrial process configurations. Aspen HYSYS and Cycle-Tempo models for a high-temperature gas-cooled reactor were developed to evaluate the proposed integration. This introductory evaluation provides a general description and assessment of the operating principles, reactor coolant core outlet temperature, and reactor size to be integrated with industry. The industrial processes of oil refining and the production of methanol, pulp and paper were simulated by using Aspen HYSYS, Aspen Plus, and the PRELIM (Petroleum Refinery Life Cycle Inventory Model) tool to develop process details. Cycle-Tempo models then extend the process modeling results to obtain net energy demands (e.g., heat, steam, and electricity) when accounting for process steam and waste heat recovery. This information is intended to foster the analysis of integrating an SMNR to decarbonize industrial facilities. The SMNR would provide reliable, competitive, and sustainable clean energy while reducing carbon emissions and other environmental impacts, such as water withdrawals, consumption, and contamination. The refining industry, exhibited in Figure ES1, is a leading consumer of fossil -fuel-based heat, power, and hydrogen in the U.S. industrial sector, generating over 164 million metric tons (MMT) of CO 2 emissions in 2023. The overall mass and energy pertaining to a generalized complex refinery in the United States is reflected in Figure ES1, along with energy metrics regarding integration with a nuclear power plant (NPP). Data sheets were developed to indicate the energy requirements for the overall refinery and each refinery process. The data sheet for the overall refinery is shown in Table ES2.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A diagnostic model to estimate winds and small-scale drag from Mars Observer PMIRR data

Theoretical and modeling studies indicate that small-scale drag due to breaking gravity waves is likely to be of considerable importance for the circulation in the middle atmospheric region (approximately 40-100 km altitude) on Mars. Recent earth-based spectroscopic observations have provided evidence for the existence of circulation features, in particular, a warm winter polar region, associated with gravity wave drag. Since the Mars Observer PMIRR experiment will obtain temperature profiles extending from the surface up to about 80 km altitude, it will be extensively sampling middle atmospheric regions in which gravity wave drag may play a dominant role. Estimating the drag then becomes crucial to the estimation of the atmospheric winds from the PMIRR-observed temperatures. An interative diagnostic model based upon one previously developed and tested with earth satellite temperature data will be applied to the PMIRR measurements to produce estimates of the small-scale zonal drag and three-dimensional wind fields in the Mars middle atmosphere. This model is based on the primitive equations, and can allow for time dependence (the time tendencies used may be based upon those computed in a Fast Fourier Mapping procedure). The small-scale zonal drag is estimated as the residual in the zonal momentum equation; the horizontal winds having first been estimated from the meridional momentum equation and the continuity equation. The scheme estimates the vertical motions from the thermodynamic equation, and thus needs estimates of the diabatic heating based upon the observed temperatures. The latter will be generated using a radiative model. It is hoped that the diagnostic scheme will be able to produce good estimates of the zonal gravity wave drag in the Mars middle atmosphere, estimates that can then be used in other diagnostic or assimilation efforts, as well as more theoretical studies.

Barnes, J. R.↗

Open-Source Conceptual Sizing Models for the Hyperloop Passenger Pod

Hyperloop is a new mode of transportation proposed as an alternative to California's high speed rail project, with the intended benefits of higher performance at lower overall costs. It consists of a passenger pod traveling through a tube under a light vacuum and suspended on air bearings. The pod travels up to transonic speeds resulting in a 35 minute travel time between the intended route from Los Angeles and San Francisco. Of the two variants outlined, the smaller system includes a 1.1 meter tall passenger capsule traveling through a 2.2 meter tube at 700 miles per hour. The passenger pod features water-based heat exchangers as well as an on-board compression system that reduces the aerodynamic drag as it moves through the tube. Although the original proposal looks very promising, it assumes that tube and pod dimensions are independently sizable without fully acknowledging the constraints of the compressor system on the pod geometry. This work focuses on the aerodynamic and thermodynamic interactions between the two largest systems; the tube and the pod. Using open-source toolsets, a new sizing method is developed based on one-dimensional thermodynamic relationships that accounts for the strong interactions between these sub-systems. These additional considerations require a tube nearly twice the size originally considered and limit the maximum pod travel speed to about 620 miles per hour. Although the results indicate that Hyperloop will need to be larger and slightly slower than originally intended, the estimated travel time only increases by approximately five minutes, so the overall performance is not dramatically affected. In addition, the proposed on-board heat exchanger is not an ideal solution to achieve reasonable equilibrium air temperatures within the tube. Removal of this subsystem represents a potential reduction in weight, energy requirements and complexity of the pod. In light of these finding, the core concept still remains a compelling possibility, although additional engineering and economic analyses are markedly necessary before a more complete design can be developed.

design analysis↗

Laboratory Scale Testing of Ignition Overpressure for Space Vehicle Launch Pad Environments

A scale model of a NASA representative space vehicle is used to develop a refined estimate of the transient pressure loads that are expected to form at the base of the vehicle in the event of a vapor cloud explosion. Flammable vapor clouds are known to form prior to engine startup due to the significant amount of unburned hydrogen that is ejected from the combustion chamber. In the event of a vapor cloud explosion, the vehicle and payload must be able to withstand the resulting overpressure waves. The study comprises an array of pressure sensors located along the base heat shield of the scale model space vehicle as well as the interior wall and throat plug plane of the solid rocket booster. A spark source generator is used to simulate the overpressure wave produced by a vapor cloud explosion while measurements are acquired with and without the effect of a mobile launcher. Time- resolved schlieren images of the simulated vapor cloud explosion reveal the path and impact of both the initial wave and several reflected waves on the various components at the base of the space vehicle. In some instances, the reflected waves superpose to create waves that are higher in amplitude than the initial overpressure wave. A time frequency analysis of the pressure waveforms measured inside the solid rocket booster reveal a ring down tone corresponding to a standing wave that is four times the length of the nozzle.

Tinney, Charles E.↗

Validation of a Computational Fluid Dynamics (CFD) Code for Supersonic Axisymmetric Base Flow

The ability to accurately and efficiently calculate the flow structure in the base region of bodies of revolution in supersonic flight is a significant step in CFD code validation for applications ranging from base heating for rockets to drag for protectives. The FDNS code is used to compute such a flow and the results are compared to benchmark quality experimental data. Flowfield calculations are presented for a cylindrical afterbody at M = 2.46 and angle of attack a = O. Grid independent solutions are compared to mean velocity profiles in the separated wake area and downstream of the reattachment point. Additionally, quantities such as turbulent kinetic energy and shear layer growth rates are compared to the data. Finally, the computed base pressures are compared to the measured values. An effort is made to elucidate the role of turbulence models in the flowfield predictions. The level of turbulent eddy viscosity, and its origin, are used to contrast the various turbulence models and compare the results to the experimental data.

Tucker, P. Kevin↗

Molten Salt Loop Operational Experience and Test Campaigns in FY24

The Facility to Alleviate Salt Technology Risks (FASTR) at the US Department of Energy (DOE) Oak Ridge National Laboratory (ORNL) was developed to demonstrate technology for high-temperature chloride salt systems (Figure 1). FASTR is primarily constructed using alloy C-276 and is designed to operate at temperatures of up to 725°C. The facility is loaded with 250 kg of NaCl-KCl-MgCl 2 salt. This salt provides a relevant test environment for de-risking technology while avoiding the costs and hazards associated with beryllium-based or uranium-bearing salts. The facility’s major components include a centrifugal pump for salt circulation, an air-based heat exchanger to reject heat, a suite of instrumentation, and trace heating to prevent salt freezing. The salt was purified in 2020 and 2022, and the pumped loop first operated in December 2022. FASTR is a unique US capability for high-temperature molten halide salt testing. FASTR’s scale, co located purification system, and relatively large power (465 kW) differentiates it from other testing systems. Furthermore, access to the DOE-supported facility and efficient communication of results— which are generally disseminated publicly—distinguish FASTR as being broadly significant throughout the molten salt reactor community. FASTR is similar to ORNL’s Liquid Salt Test Loop (LSTL), although FASTR contains chloride-based salt instead of the fluoride-based salt (LiF-NaF-KF) found in LSTL. Furthermore, FASTR is approximately 2× larger than LSTL in terms of pipe size and length, power, salt volume, flow rate, and number of thermocouples. The LSTL first operated in 2016. At the end of FY23, there was a suspected gas leak in the LSTL that halted operation. At the start of FY24, a leak in the LSTL pump’s tank gas space was confirmed. Because the gas-space leak prevented operation of LSTL, FY24 efforts were focused on operation of FASTR. This report summarizes the progress made during FY24 in support of the DOE Office of Nuclear Energy (DOE-NE) work package, AT-24OR070202 Salt Loop and Capability for Testing Sensors and Off Gas Components.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Metal additively manufactured wavy fin cold-plate architecture for improved thermal-hydraulic performance

Rapid growth in artificial intelligence and data center workloads demands high-performance liquid cooling to manage increasing chip power. This study presents two metal-additive-manufactured cold plates with sinusoidal fins, constant-amplitude wavy fins and linearly variable-amplitude wavy fins and compares them against metal-additive-manufactured straight fins using experiments conducted at 1 kW heat dissipation as well as high-fidelity 3D conjugate computational fluid dynamic simulations. The cold plates were printed in AlSi10Mg material and underwent design using a Python-automated workflow prior to manufacture and testing. The experiments show that wavy fins reduce the normalized thermal resistance by 35 to 45 % at water flow rates from 1 to 4 LPM. At a fixed 20 kPa pressure drop, the variable-waviness design lowered peak surface temperature by 9 °C and thermal resistance by 51 %, while edge-channel maldistribution in the constant wavy fin design limited gains. A thermal resistance breakdown revealed that 55–63 % of the total thermal resistance in wavy designs comes from base heat conduction, 27–33 % from fin heat conduction, and 9–13 % from fin heat convection, indicating the need to address conduction bottlenecks. Parametric sweeps identify a 3 mm fin pitch as optimal, and that horizontal inlet/outlet manifolds further reduce pressure drop by 30–60 % and thermal resistance by 9–16 % relative to vertical inlet-outlet manifolds. The results yield comprehensive guidelines for fin geometry, manifold alignment, material selection and additive-manufacturing constraints to realize high-performance liquid-cooled cold plates for power-dense electronics.

3d printing↗

Roadmap on thermodynamics and thermal metamaterials

Thermal metamaterials represent a transformative paradigm in modern physics, synergizing thermodynamic principles with metamaterial engineering to master heat flow at will. As next-generation technologies demand multi-scale thermal control, this field urgently requires systematic frameworks to unify its multidisciplinary advances. Curated through a global collaboration involving over 50 specialists across 25 subdisciplines, this review primarily summarizes two decades of advancements, ranging from theoretical breakthroughs to functional implementations. The review reveals groundbreaking innovations in heat manipulation through the exploration of both classical and non-classical transport regimes, topological thermal control mechanisms, and quantum-informed phonon engineering strategies. By bridging physical insights like non-Hermitian thermal dynamics and valleytronic phonon transport with cutting-edge applications, we demonstrate paradigm-shifting capabilities: environment-adaptive thermal cloaks, AI-optimized metamaterials, and nonlinear thermal circuits enabling heat-based computation. Experimental milestones include 3D thermal null media with reconfigurable invisibility and thermal designs breaking classical conductivity limits. Here, this collaborative effort establishes an indispensable roadmap for physicists, highlighting pathways to quantum thermal management, entropy-controlled energy systems, and topological devices. As thermal metamaterials transition from laboratory marvels to technological cornerstones, this work provides the foundational lexicon and design principles for the coming era of intelligent thermal matter.

heat conduction control↗

Mitigation of safety and environmental challenges posed by refrigerants

The abatement of safety and environmental burden associated with low and ultra-low Global Warming Potential (GWP) refrigerants is a critical undertaking. As the industry shifts towards more environmentally friendly alternatives, mitigating the potential risks and ensuring safety standards becomes paramount. The adoption of mildly and highly flammable refrigerants contributes significantly to minimizing the greenhouse gas impact on the environment, aligning with global climate and sustainability goals. However, it is essential to address safety concerns and potential environmental implications associated with the end use of these refrigerants. A method to mitigate the safety risk in a flammable refrigerant based heating, ventilation, air-conditioning, and refrigeration (HVACR) system is the primary focus of this paper. Advent of A2L and A3 refrigerants as replacements to high GWP refrigerants requires careful handling of leak episodes to lower or eliminate the risk associated with creating flammable mixtures capable of fire/explosion hazard. Solid materials tailored to target the molecule of interest (i.e., refrigerant.) by engineering the microporous structure as well as chemically functionalizing the surface to attract and hold on to the chemical compound being removed from the gas stream was realized. Quantitative analysis reveals the adsorbent's effectiveness in reducing leak potential in the range of 40 %–100 % for various refrigerants. Strategic placement and active leak management with negative pressure offer promising avenues for capturing leaked refrigerants, enhancing overall safety.

42 ENGINEERING↗