Search NASA⌕ Search

SEARCH · Search NASA

Results for “BELLOWS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A technique for dynamically calibrating pressure transducers at cryogenic temperatures

A technique was developed for the calibration of dynamic pressure transducers at cryogenic temperatures. The calibration system utilizes an 8.9 Newton peak thrust shaker which oscillates a helium-filled bellows to generate a sinusoidal dynamic pressure to calibrate transducers immersed in a cryogenic environment. The system has a dynamic pressure measurement uncertainty of approximately 11% and is capable of producing peak-to-peak dynamic pressure amplitudes of 1.4 kPa over a frequency range of 40 to 100 hertz and a temperature range of 100 to 300 K. It provides an unprecedented capability of both static and dynamic calibration of pressure transducers from ambient to cryogenic temperature.

Gibbens, B. V.↗

Method of reducing temperature in high-speed photography

A continuing problem in high-speed motion picture photography is adequate lighting and the associated temperature rise. Large temperature rises can damage subject matter and make recording of the desired images impossible. The problem is more severe in macrophotography because of bellows extension and the necessary increase in light. This report covers one approach to reducing the initial temperature rise: the use of filters and heat-absorbing materials. The accompanying figures provide the starting point for selecting distance as a function of light intensity and determining the associated temperature rise. Using these figures will allow the photographer greater freedom in meeting different photographic situations.

Walker, E. D.↗

Development of 2 underseat energy absorbers for application to crashworthy passenger seats for general aviation aircraft

This report presents the methodology and results of a program conducted to develop two underseat energy absorber (E/A) concepts for application to nonadjustable crashworthy passenger seats for general aviation aircraft. One concept utilizes an inflated air bag, and the other, a convoluted sheet metal bellows. Prototypes of both were designed, built, and tested. Both concepts demonstrated the necessary features of an energy absorber (load-limiter); however, the air bag concept is particularly encouraging because of its light weight. Several seat frame concepts also were investigated as a means of resisting longitudinal and lateral loads and of guiding the primary vertical stroke of the underseat energy absorber. Further development of a seat system design using the underseat energy absorbers is recommended because they provide greatly enhanced crash survivability as compared with existing general aviation aircraft seats.

Warrick, J. C.↗

Measuring Metal Thickness With an Electric Probe

Thickness of metal parts measured from one side with aid of Kelvin probe. Method developed for measuring thickness of end plate on sealed metal bellows from outside. Suitable for thicknesses of few thousandth's of inch (few hundred micrometers). Method also used to determine thickness of metal coatings applied by sputtering, electroplating, and flame spraying.

Shumka, A.↗

Oscillation Damper With Two Spring Rates

Hydraulic damping used in device developed to stabilize vibrating structure in space. Damping mechanism stops oscillation of attached boom. Two bellows provide fluid damping. Springs are engaged when extra spring force required. Otherwise they retract. Mechanism especially useful for arresting oscillatory motion of slender boom with large mass. On Earth, such configurations arise in design of masts and cranes.

Sevilla, D. R.↗

Device for rapid quantification of human carotid baroreceptor-cardiac reflex responses

A new device has been designed, constructed, and evaluated to characterize the human carotid baroreceptor-cardiac reflex response relation rapidly. This system was designed for study of reflex responses of astronauts before, during, and after space travel. The system comprises a new tightly sealing silicon rubber neck chamber, a stepping motor-driven electrodeposited nickel bellows pressure system, capable of delivering sequential R-wave-triggered neck chamber pressure changes between +40 and -65 mmHg, and a microprocessor-based electronics system for control of pressure steps and analysis and display of responses. This new system provokes classic sigmoid baroreceptor-cardiac reflex responses with threshold, linear, and saturation ranges in most human volunteers during one held expiration.

Sprenkle, J. M.↗

Sealed Joints for Hard Suits or Robots

Shoulder-to-arm joint allows wearer to move with considerable freedom while sealing wearer from outside environment. Inner wall is set of bellows, compressed at inner arm and expanded at outer arm, but degree of compression or expansion changes continuously as arm moves. Joint also used on diving suits and on manipulation sleeves for autoclaves and high-vacuum boxes, and as protective cover for articulated torque drives in hostile environments.

Vykukal, Hubert C.↗

Stable 1.25 watts CW far infrared laser radiation at the 119 micron methanol line

Far-infrared CW radiation of 1.25 watts has been obtained at the 119 micron methanol line with a CO2 pump power of 125 watts, and the maximum frequency fluctuation of the free running laser is measured to be less than + or - 100 kHz per hour. Reflecting optics have been used, when possible, to minimize CO2 degradation, and the frequency stability is ensured by cooling the input and output couplers. The input and output assemblies within the lasing medium are enclosed to minimize the external effects on the cavity length and to eliminate the mechanical instabilities associated with the use of bellows. The vibrational bottle-neck is broken by cooling the resonator wall to 5 deg and adding He as the buffer gas.

Farhoomand, Jam↗

Experimenting With Baroreceptor Reflexes

Carotid arteries stimulated by pressure or suction on neck. Baro-Cuff is silicone-rubber chamber that fits on front of subject's neck. Electronic system, stepping motor, bellows, and umbilical tube furnish controlled pressure to chamber. Pressure sensor provides feedback to microprocessor in electronic system. Developed to study blood-pressure-reflex responses of astronauts in outer space. Useful for terrestrial studies of patients with congestive heart failure, chronic diabetes mellitus, and other conditions in which blood-pressure-reflex controls behave abnormally.

Eckberg, Dwain L.↗

In situ fatigue loading stage inside scanning electron microscope

A fatigue loading stage inside a scanning electron microscopy (SEM) was developed. The stage allows dynamic and static high-magnification and high-resolution viewing of the fatigue crack initiation and crack propagation processes. The loading stage is controlled by a closed-loop servohydraulic system. Maximum load is 1000 lb (4450 N) with test frequencies ranging up to 30 Hz. The stage accommodates specimens up to 2 inches (50 mm) in length and tolerates substantial specimen translation to view the propagating crack. At room temperature, acceptable working resolution is obtainable for magnifications ranging up to 10,000X. The system is equipped with a high-temperature setup designed for temperatures up to 2000 F (1100 C). The signal can be videotaped for further analysis of the pertinent fatigue damage mechanisms. The design allows for quick and easy interchange and conversion of the SEM from a loading stage configuration to its normal operational configuration and vice versa. Tests are performed entirely in the in-situ mode. In contrast to other designs, the NASA design has greatly extended the life of the loading stage by not exposing the bellows to cyclic loading. The loading stage was used to investigate the fatigue crack growth mechanisms in the (100)-oriented PWA 1480 single-crystal, nickel-based supperalloy. The high-magnification observations revealed the details of the crack growth processes.

Telesman, Jack↗

Thermal contact conductance of pressurized surfaces

Thermal vacuum testing has demonstrated the feasibility of the concept of pressurizing contact surfaces for the transfer of waste heat on the Space Station. Data show a thin inflatable bladder design to provide a greater contact conductance than an expandable bellows approach, with substantially less interface volume to transfer the same amount of heat. Extended vacuum testing of the Radiator-to-Thermal Bus assembly indicated a continual increase of conductance as the interface was maintained at 150 psi for a 100-hour period.

Voss, Fred E.↗

The 25 kWe solar thermal Stirling hydraulic engine system: Conceptual design

The conceptual design and analysis of a solar thermal free-piston Stirling hydraulic engine system designed to deliver 25 kWe when coupled to a 11 meter test bed concentrator is documented. A manufacturing cost assessment for 10,000 units per year was made. The design meets all program objectives including a 60,000 hr design life, dynamic balancing, fully automated control, more than 33.3 percent overall system efficiency, properly conditioned power, maximum utilization of annualized insolation, and projected production costs. The system incorporates a simple, rugged, reliable pool boiler reflux heat pipe to transfer heat from the solar receiver to the Stirling engine. The free-piston engine produces high pressure hydraulic flow which powers a commercial hydraulic motor that, in turn, drives a commercial rotary induction generator. The Stirling hydraulic engine uses hermetic bellows seals to separate helium working gas from hydraulic fluid which provides hydrodynamic lubrication to all moving parts. Maximum utilization of highly refined, field proven commercial components for electric power generation minimizes development cost and risk.

White, Maurice↗

Mixing ratios of trace gases in the austral polar atmosphere during August and September of 1987

Mixing ratios are presented for a number of long-lived trace gases in the austral polar atmosphere during August and September of 1987. The recent discovery of a 12-year trend of increasing depletion of ozone over the Antarctic Continent in the spring of each year led to numerous theoretical interpretations and several scientific expeditions to the region. The results herein were obtained as part of a major effort involving penetration of the region of ozone depletion by NASA's multi-instrumented aircraft. One of the 14 instruments on the high-altitude ER-2 aircraft collected pressurized air samples between latitudes of 53 degrees and 72 degrees south at pressure altitudes up to 21 km in a series of 12 flights from Punta Arenas, Chile, over the Palmer Peninsula. The sampling system, located in the nose section of ER-2, has an inlet tube in the free airstream, a metal-bellows air pump, and 14 specially treated 1.6 l stainless-steel canisters for containing the pressurized air at 350 kPa. A typical flight profile consisted of a southbound path on the 428 K potential temperature surface, a descent to a pressure altitude of 13.7 km, a climb to the 460 K surface, and return on this surface. Mixing ratios for the trace gases were obtained from gas chromatographic analyses of the pressurized air samples. Of the species measured, the mixing ratios for CH4, CO, N2O, CF2 Cl2, CFCl3, CH3, CCl3, CCl4, and C2F3Cl3 are reported here.

Vedder, James F.↗

Space module assembly apparatus with docking alignment flexibility and restraint

A berthing mechanism especially for use in berthing and compliant air-tight securing between manned space vehicle and modules is disclosed. The interface is provided by a pair of annular rings, one of which is typically, mechanically attached to the vehicle and the other to the module to which it is to be docked and secured. One of the two rings is attached to a base by resilient bellows. The facing surface of one annular ring is joined to a base by a cable laced through alternating pulleys attached circumferentially so that the interface surface of that ring may be tilted to accommodate angular misalignment as the annular rings are brought into docking (berthing) contact. Interleaving guide flanges with chambered sides provide at least some rotational mialignmnet correction. A plurality of electromechanical actuator/attenuator units provide means for extending one annular ring toward the other in the final stages of docking, for absorbing the initial docking shock and for drawing the annular rings into tight interface contact. Locking hooks provide for securing the interfaces.

Willie D Whitaker↗

Spot-Welding Gun With Adjustable Pneumatic Spring

Proposed spot-welding gun equipped with pneumatic spring, which could be bellows or piston and cylinder, exerts force independent of position along stroke. Applies accurate controlled force to joint welded, without precise positioning at critical position within stroke.

Burley, Richard K.↗

Circumferential pressure probe

A probe for measuring circumferential pressure inside a body cavity is disclosed. In the preferred embodiment, a urodynamic pressure measurement probe for evaluating human urinary sphincter function is disclosed. Along the length of the probe are disposed a multiplicity of deformable wall sensors which typically comprise support tube sections with flexible side wall areas. These are arranged along the length of the probe in two areas, one just proximal to the tip for the sensing of fluid pressure inside the bladder, and five in the sensing section which is positioned within the urethra at the point at which the urinary sphincter constricts to control the flow of urine. The remainder of the length of the probe comprises multiple rigid support tube sections interspersed with flexible support tube sections in the form of bellows to provide flexibility.

Holmes, Harlan K.↗

High temperature flexible seal

This device is concerned with sealing the sliding interfaces between structural panels that are roughly perpendicular to each other or whose edges are butted against one another. The gap which the seal element must seal is not uniform along the seal length requiring significant seal flexibility. The seal is mounted in a rectangular groove in a moveable structural panel. The seal comprises a plurality of rectangular shaped wafers stacked next to one another and preloaded in the axial direction to minimize leakage between wafers. The wafers are laterally preloaded to maintain sealing contact along the wafer faces which engage the adjacent wall of a sidewall using one of several approaches, such as the pressurized linear bellows. The seal accommodates distortions in the adjacent panel by relative sliding between adjacent wafers. Leakage between wafers is further minimized with good wafer surface finishes. Leakage between the seal nose and the adjacent structural panel is minimized when sealing against a distorted sidewall with relatively thin wafers and suitable seal preload apparatus. Leakage behind the seal is minimized with good groove tolerances and good sealing contact between the preload system and the back of the peripheral edge of the wafers.

Steinetz, Bruce M.↗

Wind tunnel balance

A flow-through balance is provided which includes a non-metric portion and a metric portion which form a fluid-conducting passage in fluid communication with an internal bore in the sting. The non-metric and metric portions of the balance are integrally connected together by a plurality of flexure beams such that the non-metric portion, the metric portion and the flexure beams form a one-piece construction which eliminates mechanical hysteresis between the non-metric and the metric portion. The system includes structures for preventing the effects of temperature, pressure and pressurized fluid from producing asymmetric loads on the flexure beams. A temperature sensor and a pressure sensor are located within the fluid-conducting passage of the balance. The system includes a longitudinal bellows member connected at two ends to one of the non-metric portion and the metric portion and at an intermediate portion thereof to the other of (1) and (2). A plurality of strain gages are mounted on the flexure beams to measure strain forces on the flexure beams. The flexure beams are disposed so as to enable symmetric forces on the flexure beams to cancel out so that only asymmetric forces are measured as deviations by the strain gages.

Horne, Warren L.↗