Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam sensitive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Characteristics of a high-power ion beam deflection system necessary to deflect the hypothetical asteroid 2017 PD

The July 2027 impact date for the hypothetical asteroid 2017 PDC, that is the subject of an emergency response exercise, leaves just over ten years to implement a deflection approach. The analyses herein allocates four years to the design, fabrication, assembly, test and launch of a notional high-power Ion Beam Deflection (IBD) vehicle to meet a launch readiness date no later than May 2021. Using this launch date along with estimates for the vehicle mass and performance characteristics of the electric propulsion system, low-thrust trajectory analyses indicate a 2.56-year flight time to rendezvous with 2017 PDC. This would leave 3.6 years to execute the actual deflection phase. A 160-kW IBD vehicle could deflect 2017 PDC by at least one Earth radius within this time provided the asteroid’s actual diameter was less than about 140 m and its density was 2 g/cm3 or less. Larger diameters and/or higher densities would require a higher power IBD vehicle, multiple IBD vehicles, or a longer deflection phase. Ion beam deflection is largely independent of the characteristics of the threat object, but its effectiveness, like all deflection approaches, is sensitive to both the asteroid mass and the time available for deflection. The characteristics of IBD, i.e., large standoff distance between the spacecraft and the asteroid surface, as well as ion beam divergence angles of a few degrees, facilitates the possible simultaneous use of multiple IBD vehicles to improve the performance and robustness of the asteroid deflection. The 65-cm diameter, 20-kW NEXIS ion thruster developed in support of the Jupiter Icy Moons Orbiter mission concept is particularly well suited for application to a high-power IBD system. It has demonstrated an ion beam divergence angle of approximately 2 degrees and operation at 20 kW for over 2,000 hours. Completion of the development and flight qualification of this technology would significantly reduce the risk and time necessary to respond to the discovery of potentially hazardous asteroid in the size range of 50- to 100-m diameter.

Reeves, David↗

A description of the UK Meteorological Office CCN counter

The chamber is a thermal gradient diffusion type with the upper plate at room temperature and the lower plate thermoelectrically cooled. The light from a 25W projector bulb is focused in a beam of approximations 1x3 mm in the central part of the chamber. The light scattered by drops is viewed in the forward direction (40 deg) by a microscope and a sensitive photodetector. Experiments were performed to relate the peak output from the photocell with the maximum number of drops in the beam recorded photographically. The microscope is used to check the calibration at low concentrations of CCN. The results of the experiments and the performance of the counter are reported.

Kitchen, M.↗

Adaptive Wavelength Scanning Lidar (AWSL) for 3D Mapping from Space

We present the design and performance of an adaptive wavelength scanning lidar (AWSL) for highly efficient mapping from low Earth orbit (LEO). Mapping is accomplished by steering a laser beam across 1,200 resolvable spots using wavelength tuning and grating dispersion. Any subset of these 1,200 spots can be selected by wavelength switching. The design is validated with an 1550-nm prototype using a fast wavelength-tuned (500-kHz) pulsed (2-ns) fiber laser with the beam dispersed by gratings for beam steering. Reflected pulses are detected with an eight-pixel detector array with single-photon sensitivity. Eight lidar returns are time-multiplexed to one output that is digitized with a single 1-GSPS-digitizer, to save power. A grating spectrometer rejects solar background noise spatially and spectrally, and images laser footprints on to the detector array. The gratings retain the fiber laser beam quality. We are developing a 1030-nm AWSL intended for a LEO SmallSat platform.

Guangning Yang↗

Molecular beam facility for studying mass spectrometer performance

An apparatus which produces neutral gas beams in the velocity range from thermal to 6 km/s makes possible studies simulating the motion of instruments through tenuous atmospheres. Use of the apparatus in studying the response of an open-source mass spectrometer is examined. Experiments performed include responses when the instrument is in a normal mode of operation, when the ion source potentials are adjusted to reject striking gas particles, when the beam is restricted so that portions of the ion source are struck, and when the beam strikes at angles other than normal incidence. Results indicate specular radiation of particles out of the source and stagnation ratios close to unity for normal operation. Retarding potential studies dropped the sensitivity by a factor of about 10, and as angles of attack are varied, the effect was found to depend upon beam velocity and the way the ions are initially accelerated.

Ballenthin, J. O.↗

Accuracy analysis of the semi-analytical method for shape sensitivity calculation

The semianalytical method of design sensitivity analysis that is widely used for calculating derivatives of static response with respect to design variables for structures modeled by finite elements is studied. It is shown that the method can have serious accuracy problems for shape design variables in structures modeled by beam, plate, truss, frame, and solid elements. Errors are shown to be associated with an incompatibility of the sensitivity field with the structure. An error index is developed to test the accuracy of the semianalytical method. It characterizes the difference in errors between a general finite-difference method and the semianalytical method. A method for improving the accuracy of the semianalytical method (when possible) is provided. Examples are presented to demonstrate the use of the error index.

Barthelemy, Bruno↗

Potential usefulness of CCD imagers in astronomy

Two dimensional detectors have been important in astronomy since the earliest days of the science. Recently, the requirements for greater photometric accuracy, sensitivity and spectral coverage have driven the search for better imaging devices. Electron beam readout devices with a variety of target materials and intensification schemes, including the SEC and silicon vidicons, have been used successfully. The CCD as an image detector has several potential advantages over electron beam readout devices; low noise, simple construction and geometric stability are among them.

Mccord, T. B.↗

Extraterrestrial intelligence - An observational approach

The article surveys present and proposed search techniques for extraterrestrial intelligence in terms of technological requirements. It is proposed that computer systems used along with existing antennas may be utilized to search for radio signals over a broad frequency range. A general search within the electromagnetic spectrum would explore frequency, received power flux, spatial locations, and modulation. Previous SETI projects (beginning in 1960) are briefly described. An observation project is proposed in which the earth's rotational motion would scan the antenna beam along one declination circle in 24 hours. The 15 degree beam width would yield a mapping of 75% of the sky in an 8-day period if the beam were shifted 15 degrees per day. With the proposed instrument parameters, a sensitivity of about 10 to the -21 watt/sq m is achieved at a 0 degree declination and 1.5 GHz. In a second phase, a 26 m antenna would yield an HPBW of 0.8 degrees at 1 GHz and 0.03 degrees at 25 GHz. It is noted that the described technology would provide secondary benefits for radio astronomy, radio communications, and other fields.

Murray, B.↗

Improvement of vertical velocity measurements, part 3.4B

Vertical velocities are assumed to be measurable with vertically pointing antenna beams. An exact horizontal levelling and good phase calibration of the radar antenna system can yield real main-beam directions which do not significantly differ from calculated patterns. It is, thus, anticipated that antenna beams can be pointed exactly vertically. Because of area size and near-field limitations, VHF radar antennas have typically beam widths of more than several degrees. It is known that most of the reflectivity structures detected by vertically beaming VHF radars in the troposphere, stratosphere and lower mesosphere are aspect-sensitive. It cannot a priori be assumed that these structures are exactly horizontal. A few examples are investigated to support this statement.

Rottger, J.↗

A superconducting tunnel junction receiver for 345 GHz

The design, fabrication, and testing of a quasi-particle tunnel junction receiver for use at 345 GHz are discussed. The design employs small area Nb/Nb-oxide/PbInAu edge junctions in order to keep the device capacitance small and maintain a modest value for omega R(N)C. For optimum noise performance and beam properties the mixer is contained in a waveguide mounting structure. The best sensitivity was obtained at 312 GHz where a double sideband (DSB) noise temperature of 275 K was measured. Noise temperatures of 400 K (DSB) or better were obtained out to 350 GHz.

Sutton, E. C.↗

Towards Multifunctional Characteristics of Embedded Structures With Carbon Nanotube Yarns

This paper presents recent results on research of achieving multifunctional structures utilizing Carbon Nanotube (CNT) yarns. The investigation centers on creating composite structures with CNT yarns to simultaneously achieve increases in mechanical strength and the ability to sense strain. The CNT yarns used in our experiments are of the single-ply and two-ply variety with the single-ply yarns having diameters on the order of 10-20 m. The yarns are embedded in silicon rubber and polyurethane test specimens. Mechanical tests show an increase in modulus of elasticity, with an additional weight increase of far less than one-percent. Sensing characteristics of the yarns are investigated on stainless steel test beams in an electrical bridge configuration, and are observed to have a strain sensitivity of 0.7mV/V/1000 micro-strain. Also reported are measurements of the average strain distribution along the direction of the CNT yarns on square silicon rubber membranes.

Hernandez, Corey D.↗

u-Spec Spectrometers for the EXCLAIM Instrument

The EXperiment for Cryogenic Large-aperture Intensity Mapping (EXCLAIM) is a cryogenic balloon-borne instrument that will map carbon monoxide and singly-ionized carbon emission lines across redshifts from 0to 3.5, using an intensity mapping approach. EXCLAIM will broaden our understanding of these elemental and molecular gases, and the role they play in star formation processes across cosmic time scales. The focal plane of EXCLAIM’s cryogenic telescope features sixμ-Spec spectrometers.μ-Spec is a compact, integrated grating-analog spectrometer, which uses meandered superconducting niobium microstrip transmission lines on a single-crystal silicon dielectric to synthesize the grating. It features superconducting aluminum microwave kinetic inductance detectors (MKIDs), also in a microstrip architecture. The spectrometers for EXCLAIM couple to the telescope optics via a hybrid planar antenna coupled to a silicon lenslet. The spectrometers operate from420−540 GHz with a resolving power R=λ/∆λ= 512, and employ an array of 355 MKIDs on each spectrometer. The spectrometer design targets a noise equivalent power (NEP) of 2×10−18W/√Hz (defined at the input to the main lobe of the spectrometer lenslet beam, within a 9◦half width), enabled by the cryogenic telescope environment, the sensitive MKID detectors, and the low dielectric loss of single-crystal silicon. We report on these spectrometers under development for EXCLAIM, providing an overview of the spectrometer and component designs, the spectrometer fabrication process, fabrication developments since previous prototype demonstrations, and the current status of their development for the EXCLAIM mission.

EXCLAIM Instrument↗

Pointing Reference Scheme for Free-Space Optical Communications Systems

A scheme is proposed for referencing the propagation direction of the transmit laser signal in pointing a free-space optical communications terminal. This recently developed scheme enables the use of low-cost, commercial silicon-based sensors for tracking the direction of the transmit laser, regardless of the transmit wavelength. Compared with previous methods, the scheme offers some advantages of less mechanical and optical complexity and avoids expensive and exotic sensor technologies. In free-space optical communications, the transmit beam must be accurately pointed toward the receiver in order to maintain the communication link. The current approaches to achieve this function call for part of the transmit beam to be split off and projected onto an optical sensor used to infer the pointed direction. This requires that the optical sensor be sensitive to the wavelength of the transmit laser. If a different transmit wavelength is desired, for example to obtain a source capable of higher data rates, this can become quite impractical because of the unavailability or inefficiency of sensors at these wavelengths. The innovation proposed here decouples this requirement by allowing any transmit wavelength to be used with any sensor. We have applied this idea to a particular system that transmits at the standard telecommunication wavelength of 1,550 nm and uses a silicon-based sensor, sensitive from 0.5 to 1.0 micrometers, to determine the pointing direction. The scheme shown in the figure involves integrating a low-power 980-nm reference or boresight laser beam coupled to the 1,550-nm transmit beam via a wavelength-division-multiplexed fiber coupler. Both of these signals propagate through the optical fiber where they achieve an extremely high level of co-alignment before they are launched into the telescope. The telescope uses a dichroic beam splitter to reflect the 980- nm beam onto the silicon image sensor (a quad detector, charge-coupled device, or active-pixel-sensor array) while the 1,550- nm signal beam is transmitted through the optical assembly toward the remotely located receiver. Since the 980-nm reference signal originates from the same single-mode fiber-coupled source as the transmit signal, its position on the sensor is used to accurately determine the propagation direction of the transmit signal. The optics are considerably simpler in the proposed scheme due to the use of a single aperture for transmitting and receiving. Moreover, the issue of mechanical misalignment does not arise because the reference signal and transmitted laser beams are inherently co-aligned. The beam quality of the 980-nm reference signal used for tracking is required to be circularly symmetric and stable at the tracking-plane sensor array in order to minimize error in the centroiding algorithm of the pointing system. However, since the transmit signal is delivered through a fiber that supports a single mode at 1,550 nm, propagation of higher order 980-nm modes is possible. Preliminary analysis shows that the overall mode profile is dominated by the fundamental mode, giving a near symmetric profile. The instability of the mode was also measured and found to be negligible in comparison to the other error contributions in the centroid position on the sensor array.

Wright, Malcolm↗

Accuracy of derivatives of control performance using a reduced structural model

The sensitivity of control system performance to structural changes is calculated for a multi-span beam with direct-rate feedback vibration control. Reduced models based on the natural modes of the structure are formed and derivatives of the damping ratios of the closed-loop eigenvalues are calculated. The convergence of the derivatives of the damping ratios with increasing number of modes is shown to be slower than the convergence of the damping ratios themselves. In particular, in some cases the convergence of finite-element approximations to the derivatives is much faster than the convergence of the modal approximations. The results indicate that the use of reduced models based on natural vibration modes may be ill-advised for calculating the sensitivity of control system performance to changes in the controlled structure.

Sandridge, Chris A.↗

Design concepts/parameters assessment and sensitivity analyses of select composite structural components

Formal approaches are summarized to evaluate design concepts and perform sensitivity analyses on design parameters of composite structural components for vehicles. The formal approaches include structural analyses coupled with composite micromechanics to assess the structural response of beams made from various intraply hybrids, finite element analysis in conjunction with composite mechanics to assess the structural response of panels made from strip hybrids, and sensitivity analysis through optimization to assess the effects of various design parameters on the optimum design of a panel made from angleplied composite laminates. Results obtained from these approaches are presented in graphical and tabular form to illustrate parametric studies and acceptable ranges of various design parameters.

Chamis, C. C.↗

Initial results of SEPAC scientific achievement

Electron beam injection of 5 keV, 300 mA (1.5 kW) and MPD arcjet plasma injection of 2 kJ/shot were successfully performed together with various kinds of diagnostic instruments including a high sensitivity TV camera observation in the Spacelab 1. Major scientific results obtained are studies of: (1) vehicle charge-up due to the electron beam emission and its neutralization by the MPD arcjet plasma; (2) beam-plasma interaction including the plasma wave excitation; (3) beam-atmosphere interaction such as the verification of critical velocity ionization effect; and (4) anomalous enhancement of ionization associated with a neutral gas injection into space.

Obayashi, T.↗

On singular cases in the design derivative of Green's functional

The author's prior development of a general abstract representation for the design sensitivities of Green's functional for linear structural systems is extended to the case where the structural stiffness vanishes at an internal location. This situation often occurs in the optimal design of structures. Most optimality criteria require that optimally designed beams be statically determinate. For clamped-pinned beams, for example, this is possible only if the flexural stiffness vanishes at some intermediate location. The Green's function for such structures depends upon the stiffness and the location where it vanishes. A precise representation for Green's function's sensitivity to the location of vanishing stiffness is presented for beams and axisymmetric plates.

Reiss, Robert↗

Optical Tweezer Assembly and Calibration

An Optical Tweezer, as the name implies, is a useful tool for precision manipulation of micro and nano scale objects. Using the principle of electromagnetic radiation pressure, an optical tweezer employs a tightly focused laser beam to trap and position objects of various shapes and sizes. These devices can trap micrometer and nanometer sized objects. An exciting possibility for optical tweezers is its future potential to manipulate and assemble micro and nano sized sensors. A typical optical tweezer makes use of the following components: laser, mirrors, lenses, a high quality microscope, stage, Charge Coupled Device (CCD) camera, TV monitor and Position Sensitive Detectors (PSDs). The laser wavelength employed is typically in the visible or infrared spectrum. The laser beam is directed via mirrors and lenses into the microscope. It is then tightly focused by a high magnification, high numerical aperture microscope objective into the sample slide, which is mounted on a translating stage. The sample slide contains a sealed, small volume of fluid that the objects are suspended in. The most common objects trapped by optical tweezers are dielectric spheres. When trapped, a sphere will literally snap into and center itself in the laser beam. The PSD s are mounted in such a way to receive the backscatter after the beam has passed through the trap. PSD s used with the Differential Interference Contrast (DIC) technique provide highly precise data. Most optical tweezers employ lasers with power levels ranging from 10 to 100 miliwatts. Typical forces exerted on trapped objects are in the pico-newton range. When PSDs are employed, object movement can be resolved on a nanometer scale in a time range of milliseconds. Such accuracy, however, can only by utilized by calibrating the optical tweezer. Fortunately, an optical tweezer can be modeled accurately as a simple spring. This allows Hook s Law to be used. My goal this summer at NASA Glenn Research Center is the assembly and calibration of an optical tweezer setup in the Instrumentation and Controls Division (5520). I am utilizing a custom LabVIEW Virtual Instrument program for data collection and microscope stage control. Helping me in my assignment are the following people: Mentor Susan Wrbanek (5520), Dr. Baha Jassemnejad (UCO) and Technicians Ken Weiland (7650) and James Williams (7650). Without their help, my task would not be possible.

Collins, Timothy M.↗

A high pressure modulated molecular beam mass spectrometric sampling system

The current state of understanding of free-jet high pressure sampling is critically reviewed and modifications of certain theoretical and empirical considerations are presented. A high pressure, free-jet expansion, modulated molecular beam, mass spectrometric sampling apparatus was constructed and this apparatus is described in detail. Experimental studies have demonstrated that the apparatus can be used to sample high temperature systems at pressures up to one atmosphere. Condensible high temperature gaseous species have been routinely sampled and the mass spectrometric detector has provided direct identification of sampled species. System sensitivity is better than one tenth of a part per million. Experimental results obtained with argon and nitrogen beams are presented and compared to theoretical predictions. These results and the respective comparison are taken to indicate acceptable performance of the sampling apparatus. Results are also given for two groups of experiments related to hot corrosion studies. The formation of gaseous sodium sulfate in doped methane-oxygen flames was characterized and the oxidative vaporization of metals was studied in an atmospheric pressure flowing gas system to which gaseous salt partial pressures were added.

Stearns, C. A.↗