Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam sensitive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A spatial beam property analyzer based on dispersive crystal diffraction for low-emittance X-ray light sources

Abstract The advent of low-emittance synchrotron X-ray sources and free-electron lasers urges the development of novel diagnostic techniques for measuring and monitoring the spatial source properties, especially the source sizes. This work introduces an X-ray beam property analyzer based on a multi-crystal diffraction geometry, including a crystal-based monochromator and a Laue crystal in a dispersive setting to the monochromator. By measuring the flat beam and the transmitted beam profiles, the system can provide a simultaneous high-sensitivity characterization of the source size, divergence, position, and angle in the diffraction plane of the multi-crystal system. Detailed theoretical modeling predicts the system’s feasibility as a versatile characterization tool for monitoring the X-ray source and beam properties. The experimental validation was conducted at a bending magnet beamline at the Swiss Light Source by varying the machine parameters. A measurement sensitivity of less than 10% of a source size of around 12 µm is demonstrated. The proposed system offers a compact setup with simple X-ray optics and can also be utilized for monitoring the electron source.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Photon-rejection power of the Light Dark Matter eXperiment in an 8 GeV beam

The Light Dark Matter eXperiment (LDMX) is an electron-beam fixed-target experiment designed to achieve comprehensive model independent sensitivity to dark matter particles in the sub-GeV mass region. An upgrade to the LCLS-II accelerator will increase the beam energy available to LDMX from 4 to 8 GeV. Using detailed GEANT4-based simulations, we investigate the effect of the increased beam energy on the capabilities to separate signal and background, and demonstrate that the veto methodology developed for 4 GeV successfully rejects photon-induced backgrounds for at least 2 × 10 14 electrons on target at 8 GeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beta-delayed charged-particle spectroscopy using TexAT

β-delayed charged-particle emission is a sensitive probe of three-body decays in light nuclei. Time Projection Chambers (TPCs) offer a significant advantage over traditional charged-particle spectroscopy techniques due to a low-energy threshold and a high-geometric efficiency (≈ 4π) which are essential for use with radioactive ion beams where the beam intensities are limited. The technique for high-sensitivity spectroscopy of β-delayed charged-particle emission is shown to be possible using the Texas Active Target (TexAT) TPC in conjunction with the General Electronics for TPCs (GET) system. The benchmark case studied was that of 12 N β-decay to the first α-unbound state in 12 C, the Hoyle state. Here, half-life and branching ratio measurements are presented and are in good agreement with previous studies. The efficacy of using TPCs to study such a near-threshold state and disentangle the three-body dynamics of the decay products is demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Current Status and Future Prospects for the Light Dark Matter eXperiment

The constituents of dark matter are still unknown, and the viable possibilities span a vast range of masses. The physics community has established searching for sub-GeV dark matter as a high priority and identified accelerator-based experiments as an essential facet of this search strategy. A key goal of the accelerator-based dark matter program is testing the broad idea of thermally produced sub-GeV dark matter through experiments designed to directly produce dark matter particles. The most sensitive way to search for the production of light dark matter is to use a primary electron beam to produce it in fixed-target collisions. The Light Dark Matter eXperiment (LDMX) is an electron-beam fixed-target missing-momentum experiment that realizes this approach and provides unique sensitivity to light dark matter in the sub-GeV range. This contribution provides an overview of the theoretical motivation, the main experimental challenges, how LDMX addresses these challenges, and projected sensitivities. We further describe the capabilities of LDMX to explore other interesting new and standard physics, such as visibly-decaying axion and vector mediators or rare meson decays, and to provide timely electronuclear scattering measurements that will inform the modeling of neutrino-nucleus scattering for DUNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

DEVELOPMENT OF A QUANTUM ELECTRON BEAM DIAGNOSTIC APPARATUS

Spatial properties of electron beams are the essential parameters needed in particle physics and accelerator research. Beam characterization using optical detection methods through the interaction between photons and electrons such as Compton scattering, or electro-optic sampling of the electric field of electrons have been extensively explored and successfully implemented as non-invasive diagnostics at various accelerator facilities. However, such methods often suffer from inherently low sensitivity. Here we present the study of a new type of electron beam diagnostic device for direct optical imaging of electron beams at various energy levels. The concept is based on the extremely high sensitivity of atoms, prepared in a specific "dark superposition" quantum state, to the external electric or magnetic perturbations induced by the passing charged particle, which allows atoms to change polarization of the probe light or absorb probe light and to fluoresce, enabling direct 3D imaging of the charged particles with high resolution. We report our recent experiment results and the design effort on a compact apparatus intended to be tested with the relativistic electron beams at Jefferson Laboratory.

Zhang, S.↗

Achromat Design for Multi-Pulse Test Line

This note describes the design of a 90° achromatic bend on DARHT Axis 2 to support multi-pulse target studies. The achromatic bend consists of two 45° dipole magnets with a focusing quadrupole centered between the dipoles. The optical design of the achromat is described followed by a discussion of the sensitivity to space charge and variations in the beam energy. The preliminary design of the magnets is then described with a description of the electro-mechanical parameters.

42 ENGINEERING↗

Photon Detection System Calibration for DUNE

Photon Detection System Calibration for DUNE Not scheduled 20m Conference Center (University of California, Irvine) Poster New Technologies for Neutrino Physics Poster session Speaker Denis Torres (South Dakota School of Mines and Technology) Description The Deep Underground Neutrino Experiment (DUNE) is a long baseline neutrino oscillation experiment that relies on a precise Photon Detection System (PDS) to provide accurate timing information, enhance sensitivity to low-energy and non-beam events, and support detector performance studies in liquid argon time projection chambers. Achieving these goals requires a well-understood and stable optical calibration strategy that operates reliably under cryogenic conditions. In this poster, I will present PDS calibration studies performed in ProtoDUNE, focusing on the characterization of the ultraviolet (UV) light calibration system and key optical components in the light-delivery chain. I will discuss measurements of optical fiber transmission, SMA-to-SMA connector and feedthrough interface losses, and diffuser assemblies, emphasizing wavelength dependence, attenuation, and performance under cryogenic thermal cycling and stability tests. These studies provide quantitative inputs for understanding light transport, uniformity, and long-term reliability of the PDS in large-scale liquid argon detectors, and they directly inform calibration strategies for the DUNE Far Detector.

Torres Muñoz, Denis [South Dakota Sch. Mines Tech.↗

Enhancing New Physics Searches with a Future Beam Dump Configuration at SBND

Accelerator-based neutrino experiments, especially those with high-intensity beams and highly capable detectors, offer a powerful and complementary method for probing new physics scenarios. The MiniBooNE experiment at Fermilab pioneered a special Booster Neutrino Beam (BNB) beam dump run and set new limits on sub-GeV dark matter. This white paper explores the physics opportunities enabled by operating the Short-Baseline Near Detector (SBND) at Fermilab in a future BNB beam dump configuration. Redirecting the proton beam away from the default target suppresses neutrino backgrounds, enabling SBND to significantly enhance sensitivity to many new physics scenarios. We evaluate two operational scenarios – off-target mode and a new dedicated beam dump mode – and demonstrate that both approaches can open new avenues in the search for physics beyond the Standard Model. We present two example cases, scalar dark matter and heavy neutral leptons via axion-like particle.

Dutta, Bhaskar [TAMU, College Station]↗

Status of the Mu2e experiment at Fermilab

The Mu2e experiment at Fermilab aims to measure the charged-lepton flavour violating (CLFV) neutrino-less conversion of a negative muon into an electron in the field of a nucleus with an unprecedented single event sensitivity of 3x10^{-17}. This document illustrates the physics motivation and design of the experiment.In the current schedule Mu2e is expected to start taking data in 2025 with a reduced average beam intensity for about two years (Run 1). After a shut down for the upgrade of Fermilab accelerator complex, data taking will restart at full beam intensity (Run 2). A detailed update of the expected experiment sensitivity for Mu2e Run 1 is presented, together with an estimate of the final Mu2e sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Light Dark Matter Experiment (LDMX)

The constituents of dark matter are still unknown, and the viable possibilities span a very large mass range. Specific scenarios for the origin of dark matter sharpen the focus to within about an MeV to 100 TeV. Most of the stable constituents of known matter have masses in this lower range, and a thermal origin for dark matter works in a simple and predictive manner in this mass range as well. If there is an interaction between light DM and ordinary matter, as there must be in the case of a thermal origin, then there necessarily is a production mechanism in accelerator-based experiments. The Light Dark Matter eXperiment (LDMX) is a planned electron-beam fixed-target missing-momentum experiment at SLAC that has unique sensitivity to light DM in the sub-GeV mass range. Although optimized for a missing momentum technique, LDMX is effectively a fully instrumented beam dump experiment, making it possible to search for visibly decaying signatures of dark sector particles. This would provide another outlet for LDMX to probe complementary regions of dark matter phase space for a variety of models. This contribution will give an overview of the theoretical motivation for LDMX, the main experimental challenges and how they are addressed, as well as projected sensitivities in comparison to other experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CHICOX, a heavy-ion detection system for GRETA

The CHICOX detection system is an array of position sensitive parallel plate avalanche counters used for heavy ion detection in in-beam particle-gamma coincidence experiments. CHICOX, an upgrade of the CHICO2 array, is geometrically compatible with the GRETINA and GRETA gamma-ray arrays and provides an angular resolution sufficient to utilize the excellent position resolution of GRETINA/GRETA. CHICOX was successfully commissioned and fielded as an auxiliary detector to GRETINA in a campaign of stable-beam Coulomb excitation experiments at the ATLAS facility of Argonne National Laboratory. We report here on the design and in-beam performance of the CHICOX array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results of the first implementation of RF phase signature matching at LANSCE

The LINAC at the Los Alamos Neutron Science Center (LANSCE) has been utilizing the Delta-t method to match the RF cavities to the design acceleration parameters since its commissioning in 1972. The differences in time-of-flight between two subsequent Beam Position and Phase Monitors (BPPMs) are measured with both accelerated and drifting beams, depending on the whether the module is set to on or off. The algorithm optimizes the module amplitude and phase via iterative measurements if the initial phase is in the vicinity of the design value. With an upgrade to a faster readout system, a scan over the whole RF cavity phase range requires relatively less time than the classical optimization procedure. The Phase Scan Signature Matching (PSSM) method provides a time-efficient method that ensures the phase selection lands on the bunching side and empowers future analyses to build module-specific models. The PSSM also utilizes a direct model to determine the correct amplitude to sub-percent level instead of using linearized matrices. Furthermore, lacking a reliable energy measurement method in the LINAC, we measure the beam phases at two downstream locations to increase the precision of energy measurements. In this letter, we also discuss the sensitivities of PSSM, error propagation, and the implementation results for the 2019 and 2020 beam cycles.

47 OTHER INSTRUMENTATION↗

Low-energy muon and muonium beam source at Fermilab

We describe a high-efficiency source of muonium that can be transported as a beam in vacuum provides opportunities for fundamental muon and precision physics measurements such as sensitive searches for symmetry violation. Although PSI is currently the world leader, the intense 800-MeV PIP-II linac beam at Fermilab could provide world-class low-energy muon and muonium beams, with unparalleled intensity, driving the next generation of precision muon-based physics experiments at the intensity frontier. However, it is critical to initiate the prerequisite R&D now to prepare for the PIP-II era. A low-energy secondary muon line recently installed in an operating facility (the MeV Test Area, which utilizes the intense 400-MeV Fermilab Linac beam) could support the required R&D, and potentially compete for new physics in the immediate term, if approved. This beamline was developed for μ– and will need to be re-optimized for surface μ+ production and transport, making it also suitable for muon spin rotation physics––a unique research and industrial application for which no U.S. facility exists, and whose facilities are oversubscribed worldwide.

43 PARTICLE ACCELERATORS↗

Resonance Ionization Spectroscopy Experiment at Facility for Rare Isotope Beams

This manuscript reports on the commissioning of the Resonance Ionization Spectroscopy Experiment (RISE) at the BEam COoler and LAser spectroscopy (BECOLA) facility at Facility for Rare Isotope Beams (FRIB). The instrument implements the collinear resonance ionization spectroscopy technique for sensitive measurements of isotope shifts and hyperfine structure of short-lived isotopes produced at FRIB. The existing BECOLA beamline was extended to integrate an electrostatic ion-beam bender and an ion detector at ultrahigh vacuum. An injection-seeded titanium-sapphire laser and a multiharmonic pulsed neodymium-doped yttrium aluminum garnet laser were installed to perform resonant excitation and selective ionization. Commissioning tests were performed to demonstrate the capabilities of the instrument by measuring the hyperfine structure of stable 27 Al produced in an offline ion source. The RISE instrument is ready and operational for future studies of short-lived isotopes at FRIB.

Atomic spectra↗

Acceptance Calculation and Study of Fault Scenarios in the PIP-II Linac

The Proton Improvement Plan (PIP)-II is a proposed high intensity proton facility being developed at the Fermilab. The PIP-II is primarily based on construction of a new superconducting radio frequency (SRF) linear accelerator (linac) that would deliver an average beam current of 2mA with output energy up to 800 MeV. The acceptance of an accelerator outlines its sensitivity against deviations from its nominal design parameters. Consequently, a higher acceptance minimizes possibility of the beam loss. This paper presents longitudinal and transverse acceptance of the PIP-II SRF linac. Furthermore, paper also discusses implications of fault scenarios, such as the cavity failure, on the beam optics and acceptances.

43 PARTICLE ACCELERATORS↗

Expected sensitivity of the Light Dark Matter eXperiment to long-lived dark photons and axion-like particles

The Light Dark Matter eXperiment (LDMX) is an electron-beam fixed-target experiment primarily designed to achieve world-leading, model-independent sensitivity to sub-GeV dark matter particles. LDMX aims to identify dark sector particle production through the detection of events with substantial missing energy and momentum, a signature of invisible particles escaping detection. Beyond this primary objective, LDMX offers a complementary search strategy for long-lived, visibly decaying particles, such as dark photons and axion-like particles. We present the first detailed evaluation of the ability of LDMX to identify visibly decaying, long-lived particles that couple to electrons using a detailed simulation, based on the Geant 4-toolkit, that incorporates realistic detection efficiencies and background levels. We demonstrate that LDMX can achieve a sensitivity that is competitive with other experiments that are currently running. The models explored in this paper are distinct and complementary to those probed in the LDMX flagship missing-momentum analysis. Through searching for both invisible dark matter and visibly decaying long-lived signatures, LDMX will significantly advance the search for light dark matter and provide a broad exploration of the sub-GeV dark sector.[graphic not available: see fulltext]

Akesson, Torsten [Lund U.] (ORCID:0000000341415408↗

NOvA's Current and Future Sterile Neutrino Searches

The NOvA experiment's most recent search for eV-scale sterile neutrinos under a 3+1 model simultaneously analyses muon neutrino and neutral current datasets from the NuMI beam at its Near ($\sim$\qty1{km} baseline) and Far (\qty{810}{km} baseline) detectors to look for oscillations consistent with a sterile neutrino. The analysis is systematically limited in the region of parameter space where $Δm^2_{41} \gtrsim 1~\mathrm{eV}^2$. This region of parameter space is preferred by sterile neutrino interpretations of current experimental anomalies and so improving sensitivity here is high-priority. These proceedings present our current search strategy, and discusses future plans to include data from a second beamline, the Booster Neutrino Beam, to improve our sensitivity in systematics-dominated regions of parameter space.

Lister, Adam [Wisconsin U., Madison; Virginia Tech↗

Search for a Sterile Neutrino in a 3+1 Framework using Wire-Cell Inclusive Charged-Current $\nu_e$ Selection with the BNB and NuMI beamlines in MicroBooNE

A search for a sterile neutrino is being carried out in the MicroBooNE experiment within the 3+1 (three flavors of active neutrinos + one flavor of sterile neutrino) framework using neutrinos from the Booster Neutrino Beam (BNB) and the Neutrinos at the Main Injector (NuMI). The sensitivity of this search is built upon high performance inclusive charged-current electron neutrino and muon neutrino event selections. The previous 3+1 sterile neutrino search using only BNB data, the cancellation between $\nu_{e}$ disappearance and $\nu_{e}$ appearance oscillations led to a reduced oscillation effect in the $\nu_{e}$ energy spectrum resulting in a degeneracy of the oscillation parameters. Such a degeneracy is shown to be mitigated by including the neutrino events from the NuMI beam. In this note, the prospect of a 3+1 oscillation analysis using both BNB and NuMI is reported, considerably improving the sensitivity to 3+1 neutrino oscillations.

43 PARTICLE ACCELERATORS↗