Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Thermal performance and energy consumption validation of an occupied local government office building outfitted with ceiling tile phase change materials

Buildings present an opportunity for energy conservation and the modulation of peak energy demand through controlled Heating, Ventilation, and Air Conditioning (HVAC) energy use. The administrative and office building stock in the United States holds potential to achieve energy and demand savings through retrofits such as insulation, weatherization, and thermal energy storage. Specifically, there is a need to validate passive phase change material (PCM) applications in full scale in aging administrative buildings in the US to evaluate the energy benefits. Aim of this study was to conduct a whole building level thermal and energy validation of an operational building and explore an alternative method for evaluating energy efficiency. To accomplish this, the study employed PCMs in the drop ceiling and carry out an energy audit and on-site measurement of HVAC systems' energy demand and consumption. A full-scale EnergyPlus energy model, modeled by the authors, served as a baseline for evaluation. The results show that calibrated model's envelope temperature measures fall within the accepted errors. HVAC energy simulation results also fall within the accepted errors for monthly and hourly pre- and post- PCM retrofit electricity and natural gas data. The novelty of this study is that it employees energy scales per Heating Degree Hour and Cooling Degree Hour, in contrast to the commonly used Heating Degree Days and Cooling Degree Days as reported in the literature to analyze energy savings. These findings underscore the pivotal role of a calibrated model in assessing the efficacy of a singular energy measure, like a PCM-retrofitted ceiling, in an occupied office building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Review of data-driven models for quantifying load shed by non-residential buildings in the United States

Shifting and shedding power demand in buildings can be cost-effective techniques for grids to function reliably and for end users to earn compensation. Grid operators reimburse customers in proportion to the quantity of load shed. Simple data-driven methods are used to quantify this shed, which is the difference between a measured load during the event and modeled "baseline" that would have occurred in absence of the event. These methods have evolved over the years and in many cases have been integrated with building physics, to make them a hybrid between physics based and empirical models. However, there is no comprehensive analysis that provides guidance to building operators, grid operators and researchers in selecting appropriate models based on their specific needs and available data. Here, this work aims to fill this gap by critically assessing the performance of baseline models put forward from the year 2000 through 2023. The literature reviewed includes reports generated by grid operators, reports from national laboratories and academic journal articles. The work outlines modeling features like the inputs, training period, estimation method, adjustments to fine tune the predictions and metrics to evaluate the performance. A comprehensive list of 50 models has been provided. For each model, the study explores the applicability of the model to weather sensitive buildings, variability in the building profile, timing of the event, and whether the building reduces energy consumption before an event. The work identifies the situations in which a particular model works and draws lessons based on evidence of performance. Finally, recommendations to aid in model selection are given.

97 MATHEMATICS AND COMPUTING↗

Coupled management of electric vehicle workplace charging and office building loads

Significant building energy savings are realized through heating, ventilation, and air conditioning (HVAC) setpoint adjustment and daylighting control. Workplace charging (WPC) enables colocation of electric vehicles (EVs) with office building loads. We proposed managing energy use of workplace EV charging and the office building and determined the number of EVs that building energy savings can facilitate charging. We simulated building energy savings in typical medium offices in Chicago IL, Baltimore MD, and Houston TX, spanning three US climate regions. Considering the EV hosting capacity of the saved building energy and travel patterns of roundtrip commuting, we minimized EV charging costs under time-of-use electricity pricing. Managed WPC can reduce charging electricity bills compared to first-come, first-served charging. The ratio of EVs to chargers, the coincident period of commuters’ dwell time and lower electricity prices, and the number of EVs in the office impacted the economic benefits achieved through charging management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Supporting Growth of a Skilled Workforce in the Building Energy Efficiency Industry (Final Technical Report)

The Interstate Renewable Energy Council (IREC), having worked for well over a decade to develop national networks and best practices focused on attracting and training high quality workers for the clean energy industries, sought to address shortfalls in skilled workers who build, retrofit, operate, and maintain energy efficient buildings. Through this project, IREC created and promoted a Green Buildings Career Map (GBCM)—a career awareness and recruitment tool—that seeks to boost the nationwide growth of workers entering the energy efficiency (EE) industry. Working with a team of subject matter experts and our partner organizations—Building Performance Association (BPA), Building Performance Institute (BPI), Community Action Partnership (CAP), and the National Institute of Building Sciences (NIBS)—IREC produced an interactive, engaging career map to attract and motivate individuals into pursuing careers in energy efficiency, and in support of the Weatherization Assistance Program. The GBCM was designed for a broad audience including educators, career advisors, employers, policymakers, workforce professionals, and jobseekers who may otherwise have little or no awareness of the exciting and rewarding opportunities within targeted industry sectors. Most individuals seeking careers do not know about the breadth of careers awaiting them in the built environment and the same is true for most career and guidance counselors, educators, and parents. The GBCM provides this broad audience with a vision of the myriad jobs that could lead to a long-standing career in energy efficiency. The GBCM describes diverse occupations across the EE industry, charts possible progression between those occupations, and identifies the training, skills, and credentials necessary to do them well.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-objective sizing and dispatch for building thermal and battery storage towards economic and environmental synergy

The role of building thermal and battery storage is pivotal in advancing smart cities and achieving sustainability goals through effective energy management. Despite their significance, there are several limitations in the sizing approach and value stream analysis with various objectives for their widespread adoption in buildings. This work proposes a flexible and scalable multi-objective optimization framework for optimal sizing and dispatch of building thermal and battery storage, addressing conflicting objectives simultaneously using mixed-integer linear programming. The weighted-sum method is adapted, combining multiple objectives into a single function. The two-stage procedure iterates over different weights, generating optimal solutions and forming the Pareto front. Case studies are performed to assess the energy, economic, and environmental benefits of building energy storage systems for a large office building in three climate locations. The results demonstrate that the proposed framework efficiently determines optimal sizing and dispatch strategies, addressing the balance between economic viability and emission reduction. The dynamic relationship between time-of-use energy charges and emission factors leads to significantly different strategies based on whether economic or environmental concerns are prioritized. This research enhances our understanding of the benefits of TES and BES systems in buildings, providing valuable guidance to stakeholders.

25 ENERGY STORAGE↗

A transfer learning approach to energy-efficient control of small and medium-sized commercial buildings

Model-free reinforcement learning (RL) provides a data-driven and adaptive approach to optimize building energy use while satisfying occupant comfort. This powerful tool does not need any prior knowledge about the environment and system it is optimizing and can adapt its policy based on the changes in captures. Like any other data-driven tool, it faces high training costs due to the extensive agent-environment interactions required to capture long-term building dynamics and user comfort. Transfer learning, particularly policy distillation, offers a promising way to accelerate training by leveraging pretrained RL agents in different building and system types. Here, this study investigates online student distillation, in which the student model updates its neural network weights using outputs from teacher models. The work introduces a student distillation strategy designed for efficient knowledge transfer, along with a teacher selection method that ensures high-quality guidance. The approach is validated using a highly calibrated whole building energy model for a small/medium commercial building test facility. Results show substantial reductions in training time and data requirements while surpassing the performance of ASHRAE Guideline 36, an advanced rule-based control strategy. The distilled RL model required 45% less data and achieved 20% higher cumulative rewards than a state-of-the-art RL model, with faster convergence and lower energy consumption. These outcomes demonstrate that effective transfer learning enables a scalable and data-efficient energy management solution for commercial buildings.

ASHRAE guideline 36↗

The health and indoor environmental quality impacts of residential building envelope retrofits: A literature review

Retrofitting existing buildings to improve energy efficiency is an important strategy to meet increasingly stringent energy efficiency targets. While the primary objective of energy efficiency retrofits is to reduce energy consumption and greenhouse gas emissions, retrofits can also result in non-energy impacts (NEIs), which contribute to decision-making processes and overall value of the retrofit. NEIs have been studied extensively in retrofitted residential buildings; however, these studies have historically grouped passive (i.e., building envelope) and active (i.e., heating, ventilation, and air conditioning (HVAC) and energy system) upgrades, making it difficult to identify the underlying mechanism(s) of action for each NEI and developing effective retrofit strategies, based on occupant need. The purpose of this study was to better account for NEIs, based on a literature review, summarizing the current state of knowledge on NEIs associated with residential building envelope retrofits. We limited our search to health- and indoor environmental quality-related NEIs. The review identified strong evidence that building envelope retrofits improve acoustic comfort, wintertime thermal comfort, and respiratory and cardiovascular health outcomes. IAQ outcomes were mixed, with studies reporting both increases and decreases to indoor contaminant concentrations following retrofits. The strength of the effect was generally governed by pre-retrofit contaminant concentrations and whether indoor concentrations were dominated by indoor or outdoor sources. Most studies evaluating summertime thermal comfort identified increased incidence of summertime overheating; however, none of these studies linked the change in thermal conditions to health outcomes. Recommendations for future work include expanding studies to include more market rate housing and the health impacts of summertime overheating in retrofitted buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An approach for fast and accurate simulation of phase change material based thermal energy storage in buildings

Latent heat thermal energy storage (LHTES) has significant potential for mitigating peak electricity demand and enabling load shifting in buildings. Phase Change Material embedded heat exchangers (PCM-HX) can significantly improve energy demand management due to high storage capacity. However, PCM-HX evaluation typically depends on computationally expensive fully transient simulations, posing significant challenges for scalable system- and building-level energy assessments across different climates and system architectures. This paper presents a generalized, accurate, and computationally efficient methodology for simulating building energy systems integrated with LHTES. The PCM-HX transient performance is represented by performance maps generated using a Generalized Resistance-Capacitance Model (GRCM) that enables accurate predictions of arbitrary PCM-HXs at low computational cost. The feasibility of the proposed approach was verified using a case study considering a dual-mode heat pump-thermal energy storage (HP-TES) system simulated in Modelica with Spawn of EnergyPlus™ for a DOE prototype small office building in two locations: Tampa, FL, and International Falls, MN. The PCM-HX performance maps provided accurate predictions of PCM-HX transient behavior, with mean absolute percentage deviations within 2–4% compared to GRCM while also achieving at least 1800× reduction in computational time. Moreover, the HP-TES system achieved energy savings of up to 17.4% in Tampa, FL, and 62.2% in International Falls, MN, demonstrating the broader applicability of the proposed methodology across different climate zones. This work highlights the importance of robust PCM-HX models in enabling accurate and computationally efficient building-level simulations and enabling future research opportunities for investigating optimized HP-TES designs and advanced control strategies for grid-interactive buildings.

Modelica↗

EnergyPlus-MCP: A model-context-protocol server for ai-driven building energy modeling

Traditional building energy modeling with the EnergyPlus building performance simulation engine requires domain expertise, programming skills, and intensive manual efforts limiting its effective adoption. This paper introduces EnergyPlus-MCP, the first open-source Model Context Protocol (MCP) server specifically designed for EnergyPlus simulation workflows, establishing a new foundational infrastructure for AI-driven building energy modeling. The MCP server implements a layered architecture with 35 specialized tools spanning model management, editing and analysis, HVAC and other systems configuration inspection, and simulation execution, enabling Large Language Models to interact with EnergyPlus through conversational interfaces. The server addresses critical workflow barriers by automating model validation, streamlining energy efficiency measures modification, and providing intelligent output management with interactive visualization. Through practical demonstrations using a multi-zone building retrofit analysis, we show how the EnergyPlus-MCP server significantly reduces manual efforts while maintaining full simulation rigor. By providing accessible natural language interfaces to sophisticated building energy analysis, this approach enables scalable deployment of simulation expertise across public and private organizations, educational institutions, and research teams, fundamentally transforming traditional building energy modeling practices.

AI↗

Equitable Strategies for Residential Building Energy Efficiency and Electrification in San José, California

Hotter summers, heat waves, wildfires, and droughts are already affecting San Jose residents, with historically marginalized communities impacted first and worst. The City of San Jose has ambitious goals to make the city climate-neutral by 2030 and serve as an example for cities to accelerate climate action around the world. Electrifying and decarbonizing residential buildings are important priorities to achieve San Jose's plans to reach carbon neutrality while enabling residents to live the "Good Life 2.0" - a vision that aligns with community-identified priorities of safety, health, freedom, community, and positive experiences. This technical assistance built upon the Electrify San Jose: Framework for Existing Building Electrification to identify actionable strategies to make single- and multi-family buildings both energy-efficient and all-electric. This report is intended to provide the San Jose Climate Smart team and their partners with relevant data, insights, and actionable analysis to aid in-depth and nuanced engagements with key stakeholders. In particular, the findings in this report highlight opportunities and challenges for San Jose City Council, residents, building owners, developers, financial institutions, and utility partners instrumental in building support and earning buy-in for energy efficiency and electrification upgrades in existing buildings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Equitable Strategies for Residential Building Energy Efficiency and Electrification in San José, California [Slides]

Hotter summers, heat waves, wildfires, and droughts are already affecting San Jose residents, with historically marginalized communities impacted first and worst. The City of San Jose has ambitious goals to make the city climate-neutral by 2030 and serve as an example for cities to accelerate climate action around the world. Electrifying and decarbonizing residential buildings are important priorities to achieve San Jose's plans to reach carbon neutrality while enabling residents to live the "Good Life 2.0" - a vision that aligns with community-identified priorities of safety, health, freedom, community, and positive experiences. This technical assistance built upon the Electrify San Jose: Framework for Existing Building Electrification to identify actionable strategies to make single- and multi-family buildings both energy-efficient and all-electric. This report is intended to provide the San Jose Climate Smart team and their partners with relevant data, insights, and actionable analysis to aid in-depth and nuanced engagements with key stakeholders. In particular, the findings in this report highlight opportunities and challenges for San Jose City Council, residents, building owners, developers, financial institutions, and utility partners instrumental in building support and earning buy-in for energy efficiency and electrification upgrades in existing buildings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Impacts of Model Building Energy Codes

The Department of Energy (DOE) Building Energy Codes Program (BECP) periodically evaluates national and state-level impacts associated with energy codes in residential and commercial buildings. Pacific Northwest National Laboratory (PNNL), funded by DOE, conducted an assessment of the prospective impacts of national model building energy codes from 2010 through 2040. A previous PNNL study evaluated the impact of the Building Energy Codes Program. A 2016 study looked more broadly at overall code impacts and this report describes the methodology used for the assessment and presents the impacts in terms of energy savings, consumer cost savings, and reduced emissions at the state level and at aggregated levels. In 2021, DOE conducted an interim and limited update to its 2016 study to evaluate potential building code updates using the 2016 methodology. That interim update includes estimated savings resulting from updates to the model energy codes, including the ANSI/ASHRAE/IES Standard 90.1-2016 (ASHRAE 90.1-2016) and 2019 editions, as well as the 2018 and 2021 International Energy Conservation Code (IECC). In 2023, DOE developed a fully updated report that includes code updates (ASHRAE 90.1-2019 and 2021 IECC), as well as additional enhancements and updates, including updated energy prices, annual floorspace additions, state code adoption dates, and emission factors, among others. This current version is another fully updated report that includes code updates (ASHRAE 90.1-2022 and 2024 IECC), as well as additional enhancements and updates, including updated energy prices, state code adoption dates, emission factors, and renewable energy contribution among others. Energy codes follow a three-phase cycle that starts with the development of a new model code, proceeds with the adoption of the new code by states and local jurisdictions, and finishes when the new code is implemented and builders, architects, and engineers are required to comply with the new provisions. The development of new model code editions creates the potential for increased energy savings. After a new model code is adopted, potential savings are realized in the field when new buildings (or additions and alterations) are constructed to comply with the new code. The contributions of all three phases are crucial to the overall impact of codes and are considered in this assessment. Figure ES.1 schematically describes the analysis framework. Energy savings are expressed in terms of energy use intensity (EUI) in the figure.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Machine Learning Based Metamodel for Faster Life Cycle Assessment of Large Portfolio of Buildings

Managing a large portfolio of buildings involves decisions on reuse, retrofit, renovation, rehabilitation, and new construction, influenced by trade-offs between performance metrics such as cost, time, and operational flexibility over the building's life cycle. Traditional life cycle assessment tools for evaluating these metrics can be labor- and compute-intensive, requiring extensive data and modeling for each building. Metamodels (or surrogate models) using machine learning have been explored as faster alternatives, but training these models has been hindered by the limited availability of comprehensive data on key life cycle metrics. Recent advancements in machine learning, particularly deep learning techniques like zero-shot and few-shot learning, allow models to learn from sparse or limited data. We propose a machine learning-based metamodel that leverages these techniques for rapid estimation of key building life cycle metrics. This presentation will cover the model architecture, data collection, training, and validation processes, along with an ongoing case study applied to a large portfolio of buildings. We will discuss the model's performance in terms of accuracy, compute time, limitations, and its potential for expanding to additional life cycle metrics. This data-driven approach offers a promising direction for the rapid evaluation of large building portfolios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bridging Control and Deployment: A Cross-Layer Analysis of Scalable Building Cluster Control

Building cluster control has emerged as a promising approach for enabling flexible and coordinated operation of distributed building systems, yet its transition from pilot demonstrations to routine grid-interactive operation remains limited. This paper argues that this gap cannot be explained by control algorithms alone. Instead, it arises from interacting barriers in communication infrastructure, data and semantic interoperability, uncertainty management, stakeholder participation, market design, and policy support. Accordingly, the paper reviews both technical and non-technical barriers to building cluster control. Technical challenges include heterogeneous devices and protocols, communication latency and reliability, distributed decision-making, and uncertainty propagation across aggregated loads. Non-technical barriers include user participation, stakeholder coordination, incentive allocation, and data governance. Existing solution approaches are synthesized, including semantic interoperability frameworks, edge and hierarchical communication architectures, distributed and transactive control strategies, uncertainty-aware optimization, policy mechanisms, and market reforms. Based on this analysis, two research directions are identified: testing infrastructures that can evaluate control performance under realistic multi-building conditions, and abstraction methods that allow building clusters to interact with other energy sectors through standardized flexibility representations. Overall, the paper provides a structured review of how building cluster control can move from isolated demonstrations toward reproducible, market-compatible, and grid-relevant implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-Fidelity Modeling and Control for Building Temperature Control

The ability to control energy loads such as a building's heating, ventilation, and air conditioning (HVAC) system can help facilitate increased penetration of variable renewable energy sources into the electric grid. To be able to control these HVAC systems more effectively, detailed simulations of the corresponding building physics is becoming increasingly important. These detailed simulations can be complex, nonlinear, and can require immense computational power when used in an advanced control method such as model predictive control (MPC), prompting the need to explore less computationally intensive strategies. In this work, a multi-fidelity approach is proposed to combine samples from a complex, high-fidelity model with a simple, low-fidelity model within the MPC control loop. More specifically, the parameters of a reduced-order, linear building model are periodically updated with knowledge from its high-fidelity counterpart - an EnergyPlus model - in an online fashion using a Gaussian Process surrogate model. Hence, highly accurate predictions of current and future conditions in a building are maintained with a substantially reduced computational burden compared to using the high-fidelity models alone. In other words, this linear parameter varying model preserves the low computational requirements of a low-order linear model while accurately modeling a building's dynamics. This allows a building controller to take highly informed actions without requiring a large computational budget.

building modeling↗

Decarbonizing Building Thermal Systems: A How-to Guide for Heat Pump Systems and Beyond

Buildings account for a substantial portion of carbon emissions, primarily due to the widespread use of fossil fuels in heating systems. Decarbonization of heating is essential to meet climate targets and reduce the environmental impact of buildings. Heat pumps are capable of leveraging renewable energy sources and can provide heating and cooling in an energy-efficient manner. By leveraging heat pump technology, buildings can significantly reduce their carbon footprint, minimize energy consumption, and decrease their reliance on fossil fuels. The design and construction community plays a pivotal role in facilitating the transition to heat pump systems for heating and cooling. However, this transition requires specialized knowledge and expertise. This resource was developed for architects, engineers, and contractors in response to an industry need for a comprehensive technical resource that guides them through the intricacies of heat pump system design, installation, and maintenance. This resource provides detailed information on system sizing, selection of appropriate heat systems, heat sources, and integration with existing building systems. Moreover, it emphasizes best practices for ensuring operational efficiency, system longevity, and reliability. The development of this recourse was a collaborative effort between NREL/DOE Better Buildings Design and Construction Allies and ASHRAE Task Force for Building Decarbonization. This resource is composed of two complimentary portions that will be completed and released on separate time frames. The first portion will be completed and released in 2023, while the second portion will be released in 2024.

building thermal systems↗

Cybersecurity Considerations and Research Pathways for Grid-Interactive Efficient Buildings

Federal facilities serve critical missions and functions that require safe, reliable, and efficient operations. Digitization of several facility operations has increased the cost-effectiveness of energy usage and optimization of energy system performance. As the building controls landscape shifts to become more connected and smarter, building operators now face unique opportunities and challenges to adopt smart enabled devices that can lower energy usage while also optimizing building system performance. The grid-interactive efficient buildings (GEB) initiative aims to make buildings cleaner and more flexible through these smart devices. Smart enabled devices allow greater connectivity and control through remote operations and provide crucial data for analytics and increased efficiency. GEBs enable demand flexibility that has the potential to reduce electrical costs and transform the grid edge where buildings connect to power grids. This operation of interconnected systems, if not designed with cybersecurity practices, causes security gaps and introduces potential attack paths by adversarial and non-adversarial entities leading to disruption of operations.

building controls↗

Energy Saving Estimation of ASHRAE Guideline 36 Supervisory Setpoint Reset Controls in a Commercial Large Office Building

Designing, commissioning, and retrofitting HVAC control systems for energy efficiency is crucial, but the use of ad-hoc control sequences by designers and contractors, based on scattered information, results in diverse and sub-optimal sequences. ASHRAE Guideline 36 (G36) addresses the challenge by providing standardized, rule-based HVAC control sequences that prioritize energy efficiency. However, there is limited evaluation of their energy performance at the building level, with only a few studies primarily focused on HVAC airside systems in small-to-medium-sized commercial buildings. In this study, the energy performance of ASHRAE Guideline 36 control sequences was assessed using a large office building emulator in Chicago. The emulator features a central plant system with multiple chillers and boilers as well as multiple variable air volume (VAV) systems with terminal reheat. To achieve a high-fidelity representation, we developed a Spawn-of-EnergyPlus-based model for the large office building, maintaining the DOE prototype large office building setup but substituting the HVAC system with its Modelica counterpart. This substitution ensures that the building thermal load, HVAC system's dynamics, and detailed control sequences are all accurately represented. The study involved evaluating and implementing control strategies outlined in ASHRAE Guideline 36-2021 to replace conventional controls. These strategies include the demand-based supply air temperature and duct static pressure setpoint reset and the request logic for demand-based reset of chilled/hot water supply temperature setpoints and pipe static pressure setpoints. Energy performance was evaluated under various load conditions, including cooling, heating, and transitional seasons, both for individual control strategies and in combination. The results indicate that the collective control strategies retrofit yield greater energy savings than the sum of individual strategies, highlighting the synergistic benefits of incorporating both airside and plant-side control retrofits. Additionally, energy savings of up to 41% in the heating season, 18% in the shoulder season, and 20 % in the cooling season were observed compared to baseline control while maintaining the thermal comfort level.

ASHRAE Guideline 36, Commercial buildings, Control↗