Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building Heating Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Combined Heat and Power Technology Fact Sheet Series: District Energy

This fact sheet provides an overview of district energy systems, which are characterized by one or more central plants producing hot water, steam, and/or chilled water, which then flows through a network of insulated pipes to provide hot water, space heating, and/or air conditioning for nearby buildings. District energy systems serve a variety of end-use markets, including downtowns (central business districts), college and university campuses, hospitals and healthcare facilities, airports, military bases, and industrial complexes. By combining loads for multiple buildings, district energy systems create economies of scale that help reduce energy costs and enable the use of high-efficiency technologies such as combined heat and power (CHP).

Combined Heat and Power, CHP, District Energy, Tec↗

Brick Schema Standardized Plug Load Control Strategies for Load Reduction: Preprint

Plug loads comprise a significant percentage of commercial building energy consumption. Applying intelligent controls to turn off plug loads when unused can provide dynamic load reduction and flexibility, which are key traits of grid-interactive efficient buildings. This capability is important for equitable decarbonization as it can enable disadvantaged communities to electrify buildings without costly upgrades to electrical infrastructure. In this work, we present the effectiveness of various control strategies along with the operational lessons that informed their design. During a three-year period, we operated over 600 smart outlets in 12 university office buildings. The attached plug loads consisted primarily of printers, TVs, water dispensers, and copiers. After recording baseline power measurements for one year, we designed plug load control (PLC) strategies for each plug load type, use, and for different risk tolerance levels because PLC can potentially be disruptive to daily work. We used the Brick Schema to facilitate the management of plug load locations and other metadata. For advanced controls, we integrated the smart plugs with heating, ventilation, and air conditioning (HVAC) systems through the campus building automation system. We found static schedules to be the least disruptive and most predictable for occupants, resulting in 38% and 66% energy savings in two studies. For printers, print server-triggered PLC produced 86% savings, the highest of all strategies with minimal occupant impact. Scheduling of water dispensers and digital signage TVs produced 49% and 70% savings respectively with opportunities to improve performance with the use of HVAC occupancy data.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Low Carbon Technology Strategies: Large Office

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon large office buildings within their existing building portfolios. Large offices are typically over 50,000 square feet and often include complex heating and cooling systems.

analytics↗

A System of Agents for Supporting Optimization and Control of a Connected Community

The residential sector consumes a significant portion of the electricity sold in the United States. Above 60% of the energy used in the sector is used to operate heating, ventilation, and air conditioning (HVAC) systems and water heating (WH) systems. With the increase of intelligence in the grid and the new decision and control options enabled by the Internet of Things; control of these devices can be used to support the grid. Therefore, this article presents a scalable multiagent system for optimizing HVAC and WH systems while maintaining comfort. It allows a utility to orchestrate the shifting of energy from critical periods without direct control, but instead by using a price signal. The architecture, optimization formulation, implementation strategy and results from an implementation project are discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock™ measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) with Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modulating thermal load through lightweight residential building walls using thermal energy storage and controlled precooling strategy

Precooling is a recognized technique for reducing cooling energy in buildings during peak hours by shifting load to off-peak hours. This technique is particularly effective in buildings with high thermal mass, because of their large thermal energy storage capacity, and in commercial buildings due to their variable electricity pricing based on time-of-use rates. Precooling in residential buildings has been a matter of limited interest in the past because of their low thermal mass and typically uniform electricity pricing rate. While previous studies on precooling primarily focused on cost savings, an important aspect of precooling is the thermal load modulation, which could be very effective in managing peak demand in lightweight residential buildings integrated with thermal energy storage systems. In this study, we examine different precooling strategies to manage the heat gains in lightweight building walls integrated with phase-change materials. We create nine different precooling profiles by controlling the interior temperature, and then evaluate the influence of the precooling profiles on four key building energy performance parameters: total heat gain, peak heat gain, maximum heat gain during peak hours, and time at which peak occurs. To thoroughly understand the fundamental physics, we first consider hypothetical climates and obtain the optimal precooling strategy required to achieve maximum peak shedding and shifting while minimizing the total heat gains. We then extend the model to Baltimore, Maryland, and estimate the benefits of the optimized precooling strategy under real conditions. The optimal precooling strategy proposed in this study can shift the peak heat gain by up to 14 hours, thereby reducing the heat gain during peak period by up to 95%, at the expense of a 23% increase in the total heat gains.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ascent Heating Thermal Analysis on Spacecraft Adaptor Fairings

When the Crew Exploration Vehicle (CEV) is launched, the spacecraft adaptor (SA) fairings that cover the CEV service module (SM) are exposed to aero heating. Thermal analysis is performed to compute the fairing temperatures and to investigate whether the temperatures are within the material limits for nominal ascent aeroheating case. The ascent heating is analyzed by using computational fluid dynamics (CFD) and engineering codes at Marshall Space Flight Center. The aeroheating environment data used for this work is known as Thermal Environment 3 (TE3) heating data. One of the major concerns is with the SA fairings covering the CEV SM and the SM/crew launch vehicle (CLV) flange interface. The TE3 heating rate is a function of time, wall temperature, and the spatial locations. The implementation of the TE3 heating rate as boundary conditions in the thermal analysis becomes challenging. The ascent heating thermal analysis on SA fairings and SM/CLV flange interface are performed using two commercial software packages: Cullimore & Ring (C&R) Thermal Desktop (TD) 5.1 and MSC Patran 2007r1 b. TD is the pre-and post-processor for SINDA, which is a finite-difference-based solver. In TD, the geometry is built and meshed, the boundary conditions are defined, and then SINDA is used to compute temperatures. MSC Pthermal is a finite-element- based thermal solver. MSC Patran is the pre- and post-processor for Pthermal. Regarding the boundary conditions, the convection, contact resistance, and heat load can be imposed in different ways in both programs. These two software packages are used to build the thermal model for the same analysis to validate each other and show the differences in the modeling details.

Wang, Xiao Yen↗

An analysis of Potential Benefits of Adding Diurnal Thermal Storage in Geothermal Heat Pump Systems

Geothermal heat pumps (GHP) are highly efficient for space heating and cooling, utilizing the subsurface of the ground as seasonal energy storage through borehole heat exchangers (i.e., heat stored in summer is used to provide heating in winter, and cold stored in winter is used to provide cooling in summer). On the other hand, diurnal thermal energy storage can actively be charged and discharged for load shifting. Conventional thermal energy storage uses tanks filled with thermal storage media (such as phase change materials) and heat exchangers. It occupies building floor space or land areas outside the building, which may not be available especially in residential buildings. This paper will introduce a novel configuration that can utilize existing GHP system for both diurnal and seasonal thermal storage. This system can actively charge the ground on daily basis by injecting heat or cold in borehole heat exchangers. A simulation model was created for the novel configuration. Computer simulations were conducted using the model for the new GHP system serving a typical single-family house in three U.S. cities representing hot, warm, and cold climates. Based on simulation results, the potential benefits of load shifting and downsize of the expensive ground heat exchangers used by the GHP system were assessed.

Anees, Fady [ORNL]↗

Peak Power Minimization for Commercial Thermostatically Controlled Loads in Multi-Unit Grid-Interactive Efficient Buildings

The load profiles of most commercial and industrial consumers are characterized by brief periods of very high power consumption followed by intervals of lower demand. To encourage such consumers to flatten their load profiles, power utilities in and around the world often levy a monthly demand charge (DC) on the peak demand measured over brief intervals. In this work, we consider the joint optimization of energy costs (EC) and the instantaneous peak power of a multi-unit building which uses a hydronic heating, ventilation and cooling (HVAC) system and responds to a demand response (DR) program. Despite the non-linear structure of the problem, we show how optimal solutions can be obtained efficiently using linear programming. Next, we study the power demand patterns resulting from our proposed strategy for thermostatically controlled loads (TCLs), and evaluate the strategy’s performance for various climate zones in the US, under both typical and atypical weather conditions. Finally, the results show that depending on the ambient conditions and the tariff structure, our strategy can result in utility bill savings of up to nearly 19% compared to the baseline. The results also indicate that our power control strategy can significantly reduce the instantaneous peak power consumption in commercial TCLs.

HVAC↗

Performance of a Hybrid HVAC-Integrated Thermal Storage Device

Thermal equipment in buildings is a primary contributor to peak loads on the electrical grid. Thermal energy storage is a cost-effective strategy to decouple electric use from thermal loads, thus reducing grid peak costs for building owners. One method for storing thermal energy in a building is to integrate a phase change material (PCM) directly into the heating, ventilation, and air conditioning system. These systems often require additional glycol loops, pumps, valves, and heat exchangers to couple the storage to the cooling system and building space, which increases the complexity and cost. This work will discuss an alternate approach where the storage is added directly into the heat pump evaporator. A detailed two-dimensional finite difference heat transfer model of a PCM-refrigerant-glycol heat exchanger was developed to simulate the performance of this component. The fluid stream was discretized along the flow direction to capture changes in the fluid properties and local heat transfer rates, and the phase change material was discretized in both the x and y directions to capture the movement of the melt front. The model was used to understand the impact of different material and geometric properties on the charge and discharge characteristics of the device. Finally, a Ragone framework analogous to that used for electrochemical batteries was used to maximize the energy density and round-trip efficiency of the device while supplying loads appropriate for space cooling in buildings.

buildings↗

Thermal and electric multidomain dynamic model for integration of power grid distribution with behind-the-meter devices

As renewable energy sources like solar and wind power become more integrated into the grid, coordinated control of behind-the-meter devices is crucial for enhancing grid flexibility and reliability and for meeting cost targets, with standardized models being developed to support this transition. The increasing flexibility and uncertainty of integrated renewable energy grids, along with interactions between various subsystems, make traditional steady-state modeling insufficient to capture transient and dynamic behaviors. Current models (e.g., composite load and battery equivalent models) focus on thermodynamic or electrical characteristics but overlook critical electromechanical interactions. This limits the ability to share performance information for grid services and hampers fast dynamic simulations. In addition, motor stalling is usually triggered by a fault event and attributed to the characteristics of the mechanical torque of the motor, resulting in absorption of a large amount of reactive power during the stalling period. Further, this significant withdrawal of reactive power will deteriorate the dynamic voltage stability of power grids and cause delayed voltage recovery. Therefore, an in-depth modeling of the thermodynamics or mechanical torque is essential to study the impacts of the realistic torque characteristics of those behind-the-meter devices on power system voltage stability. This study developed a dynamic multidomain model for building HVAC systems, such as air-source heat pumps, to simulate their thermal and electrical responses to grid transients. The model can accurately predict power metrics with a mean absolute percentage error of 10%, by validating against with power system computer-aided design performance data. Case studies demonstrate the model capability of capturing the transient response to sudden voltage changes, rapid load fluctuations, and system shutdowns respectively. During a sudden voltage drop (30% for 0.1s), a fully loaded heat pump’s motor speed dropped, continued declining, and shut down after 3.6s, with severe power oscillations and a torque spike. A partially loaded unit experienced temporary oscillations but stabilized. Under higher building loads, compressor speed increased from 64% to 100%, with power and torque rising before stabilizing. In safety-triggered shutdowns, power decreased after minor fluctuations, and torque briefly spiked before dropping to zero.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advancing Mass Timber Buildings: Novel Methods Improve Thermal Assessment and Material Use

For nearly a century, thermal demand calculations for buildings have relied on simplified models developed to match the technical constraints of their era. The first standards, introduced in Germany and Austria in 1929, established climate zones and material conductivity coefficients that, with only incremental updates, still underpin many current assessments. Yet, methods such as Hot box testing, originally designed for lightweight insulation, continue to be applied for mass timber buildings, overlooking thermodynamic characteristics confer real-world advantages. Recent research at Oak Ridge National Laboratory incorporates updated methodologies, aligned with ASHRAE Standard 55 (ASHRAE, 2023) accounting for factors such as thermal inertia, inner surface temperatures, emissivity, solar gains, and dynamic outdoor conditions. These factors better reflect observed heating and cooling loads and highlight opportunities for efficient use of materials in mass timber construction. This work provides a framework for designing comfortable, resilient, and resource-efficient buildings while aligning with performance expectations in energy codes.

Pickett, Robert [International Mass Timber Allianc↗

Utilizing commercial heating, ventilating, and air conditioning systems to provide grid services: A review

The modern power grid faces multiple challenges due to an increase in the adoption of renewable generation, such as dynamically balancing supply and demand at different time scales. Demand side management in buildings plays a vital role in achieving this balance because buildings can provide grid services through a variety of building assets. However, the development of grid-interactive, efficient buildings is still in its infancy, and a systematic and holistic understanding of grid service delivery strategies in terms of energy efficiency, load shifting, load shedding and load modulating is still limited. This paper is a comprehensive review of the development and application of building-level control strategies for utilizing heating, ventilating, and air conditioning systems to provide grid services. These strategies have been investigated through numerical and experimental studies. Control algorithms, such as heuristic rule-based control and model-based control, have been used to enable the automatic control delivery of grid services. The advantages and disadvantages of the strategies are summarized and discussed. Finally, research trends are also identified, which include considering predicted mean vote-based and occupant-based thermal comfort, modeling of occupant behavior, integrating power grid operations with building control, and combining different demand flexibility modes in the control design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat Based Power Augmentation for Modular Pumped Hydro Storage in Smart Buildings Operation

In the U.S., building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground-level. This unique design eliminates the geographical limitation associated with existing state of the art energy storage technologies. It is easy to be scaled for building level, community level and grid level applications. Using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g. from thermal storage, Combined Cooling, Heat and Power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Several groups of comparison experiments have been conducted and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

Chen, Yang↗

NECAP 4.1: NASA's Energy-Cost Analysis Program input manual

The computer program NECAP (NASA's Energy Cost Analysis Program) is described. The program is a versatile building design and energy analysis tool which has embodied within it state of the art techniques for performing thermal load calculations and energy use predictions. With the program, comparisons of building designs and operational alternatives for new or existing buildings can be made. The major feature of the program is the response factor technique for calculating the heat transfer through the building surfaces which accounts for the building's mass. The program expands the response factor technique into a space response factor to account for internal building temperature swings; this is extremely important in determining true building loads and energy consumption when internal temperatures are allowed to swing.

Jensen, R. N.↗

The Liquid Nitrogen System for Chamber A: A Change from Original Forced Flow Design to a Natural Flow (Thermo Siphon) System

NASA Johnson Space Center (JSC) in Houston is currently supplementing its 20K helium refrigeration system to meet the new requirements for testing the James Web Space Telescope in the environmental control Chamber-A (65 dia x 120 high) in Building 32. The new system is required to meet the various operating modes which include a high 20K heat load, a required temperature stability at the load, rapid (but controlled) cool down and warm up and bake out of the chamber. This paper will present the proposed modifications to the existing helium system(s) to incorporate the new requirements and the integration of the new helium refrigerator with the existing two 3.5KW 20K helium refrigerators. In addition, the floating pressure process control philosophy to achieve high efficiency over the operating range (40% to 100% of the refrigeration system capacity), and the required temperature stability of +/- 0.25 K at the load will be discussed. The refrigeration systems ability to naturally seek the operating conditions under various loads and thus minimizing operator involvement and the over all improvements to the system operability and the reliability will be explained.

Homan, Jonathan↗