Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building energy model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

The role of above-code labeling programs in reducing CO 2 e emissions in residential buildings

Residential buildings account for 15 % of total U.S. carbon dioxide (CO 2 ) emissions. Voluntary, above-code labeling programs, such as the ENERGY STAR and Zero Energy Ready Home programs, can play a crucial role in reducing the carbon footprint of the new construction residential building sector by encouraging adoption of more energy-efficient and lower emissions building practices and technologies. It's important for the industry to understand the carbon dioxide equivalent (CO 2 e) and energy cost savings potential of these programs. Here, to estimate the potential CO 2 e emissions savings for homes built to above-code labeling program levels, it is imperative to have reliable and accurate tools for estimating emissions from buildings. The open-source OpenStudio-ERI workflow employs detailed physics-based building energy modeling (BEM) to estimate energy usage and operational CO 2 e emissions. In this study we use the OpenStudio-ERI workflow and regional, time-varying emissions factors from the Cambium database to compare the CO 2 e emissions and energy costs of homes built to performance levels required by these above-code labeling programs relative to homes built to model energy codes. We present the results of our analysis and provide a range of emissions and annual energy cost savings for the above-code labeling programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy performance evaluation of the ASHRAE Guideline 36 control and reinforcement learning–based control using field measurements

This study evaluates the energy performance of ASHRAE Guideline 36–compliant control (ASHRAE 36 control) and reinforcement learning (RL)–based control through experimental field tests and a simulation study. Three field tests were conducted at Oak Ridge National Laboratory’s commercial building test facility in Oak Ridge, Tennessee: a baseline with a baseline conventional control, a test with ASHRAE 36 control, and a test with RL-based control. The selected ASHRAE 36 controls were trim and respond control, as well as variable air volume (VAV) box control. We compared the measured supply air temperature of the rooftop unit, VAV box supply air temperature, and VAV box supply airflow rate across the three test cases. The field data indicated that ASHRAE 36 controls operated as specified by ASHRAE Guideline 36. Based on these data, ASHRAE 36 control achieved a 45 % reduction in hourly averaged HVAC energy consumption compared with the baseline, and RL-based control achieved a 66 % reduction. These potential annual energy savings were confirmed using a calibrated whole-building energy model. Compared with the baseline, ASHRAE 36 control reduced HVAC energy consumption by 42 %, and RL-based control achieved a 54 % reduction. Furthermore, RL-based control reduced total HVAC energy consumption by 21 % more than ASHRAE 36 control.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The value of integrating a geothermal district heating system into a microgrid

As electrical grids increasingly rely on variable renewable energy, maintaining reliability and cost efficiency becomes more complex. To address these challenges, this study analyzed the integration of geothermal district heating as a grid-responsive thermal resource within a microgrid in Tuttle, Oklahoma. Building energy modeling using EnergyPlus estimated annual district heating demand at 2.9 GWh, with a peak load of 2.8 MW th . Techno-economic analyses were conducted to meet the heating demand under three geothermal scenarios, varying by production depth, flow rate, and thermal output, each supplemented by natural gas peaking boilers. In parallel, equivalent electrical load profiles were developed using typical coefficients of performance (COPs) for air-source heat pumps and electric boilers to establish an electrified baseline scenario. A complete end-use electrical load profile was also developed for the microgrid using Cambium dataset. The modeling results demonstrated reliable and economic operation of the geothermal systems over 30 years, with COPs ranging from 2.6 to 8.9 and the lowest levelized heating cost at $\$$54.6/MWh. Geothermal integration reduced electricity consumption by up to 94.7 % compared to the non-geothermal base case, yielding annual energy savings of up to $\$$803 k. Avoided grid costs ranged from $\$$65 k–$\$$147 k per year, with individual events avoiding up to $\$$4,863 per hour. Grid-responsive operation further reduced wholesale energy costs by 53–56 %. These findings demonstrate geothermal heating, traditionally treated as a non-grid-responsive thermal resource, can be reconfigured to support dynamic grid services, offering a scalable pathway to enhance reliability and reduce costs in renewable-rich microgrids and district heating networks.

15 GEOTHERMAL ENERGY↗

Datasets of a Multizone Office Building under Different HVAC System Operation Scenarios

Abstract This study provides an open-source dataset of the measured weather data, building indoor data, and system data under the different test settings. The test building is the two-story Flexible Research Platform building at the US Department of Energy’s Oak Ridge National Laboratory, in Oak Ridge, Tennessee. Four heating tests and three cooling tests were conducted. The 1-min interval of weather, building indoor data, and system data from each test setting are provided. Actual weather data were collected from a weather station installed on the roof. This paper describes information on the test building and installed sensors, data collection method, and data validation. The provided dataset can be employed to understand HVAC system conditions and building indoor conditions under different HVAC system operations and the performance of building envelope without HVAC system operation using free-floating test data. Additionally, it can be used for empirical validation of the building energy modelling engine.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PVwindow (Photovoltaic Window Simulator) [SWR-22-01]

PVwindow simulates photovoltaic window properties by allowing the user build stacks of thin film materials that compose the window layers. The only needed inputs are the complex refractive indices and thicknesses of the materials. The software will simulate the optical transmission, front reflection, and back reflection of the stack using the transfer matrix method. Properties specific to PV window optics such as visible transmittance and color are also calculated. The optics code extracts the number of absorbed photons in the PV absorber layer and solves the single diode equation to yield theoretical photovoltaic metrics such as power conversion efficiency, fill factor, open circuit voltage, and short circuit current of the PV window when illuminated at an arbitrary angle or from either side of the stack. The software tool ultimately allows researchers to design photovoltaic windows and simulate their properties. The software also exports files that can be read into LBL Window software or into the EnergyPlus and Open Studio building energy modeling software to determine larger scale energy impacts of PV window integration.

Wheeler, Lance↗

pnnl/openstudio-building-energy-standard-measures-gem

The OpenStudio Building Energy Standards Measure Repository is a comprehensive collection of innovative OpenStudio measures designed to facilitate energy code analysis. OpenStudio is a cutting-edge platform brings together physics-based building energy modeling (BEM), BEM process automation, and large-scale computing capabilities. Contains OpenStudio Standards Performance Rating Method Measure (IPID 32936) and OpenStudio Measure to Generate IPLV-specific Chiller Performance Curves for Chillers (IPID 32940)

Xu, Weili [PNNL]↗

Deep Design Data Portal (D3P) v0.01

The Deep Design Data Portal (D3P) tool was developed to demonstrate how readily accessible data sources, such as building energy model reports for design and baseline energy performance data for projects, can provide the data required for reporting to an industry initiative (AIA 2030 commitment), as well as more detailed data that makes the industry dataset more valuable to all stakeholders, enabling project level analysis and analysis of BEM industry trends. D3P provides an easier and less time-consuming way for firms to auto-extract data from this data source, compared to the current reporting workflows of the firms. The BEM reports are the first of several data sources that D3P could integrate. D3P also provides the ability for firms to review, compare, and evaluate the performance of their projects to not only their portfolio, but also to the larger anonymized industry dataset created each time a project is added to D3P. The intent of D3P is to become part of a data-sharing ecosystem to assist creating large anonymized industry datasets that are accessible to industry.

Regnier, Cynthia [Lawrence Berkeley National Labor↗

End-Use Load Profiles for the U.S. Building Stock: Market Needs, Use Cases, and Data Gaps

States and utilities are developing increasingly ambitious energy goals. Part of the solution to meeting these goals is improving electric grid flexibility. This includes shifting electric demand to align with grid needs. Thus, identifying and using building energy efficiency and other distributed energy resources to produce the highest grid value requires highly resolved, accurate and accessible electricity end-use load profiles (EULPs). EULPs quantify how and when energy is used. Currently, few accurate and accessible end-use load profiles are available for utilities, public utility commissions, state energy offices and other stakeholders to use to prioritize investment and value energy efficiency, demand response, distributed generation and energy storage. High-quality EULPs are also critical for determining the time-sensitive value of efficiency and other distributed energy resources, and the widespread adoption of grid-interactive efficient buildings (GEBs).For example, EULPs can be used to accurately forecast energy savings in buildings or identify energy activities that can be shifted to different times of the day. This report serves as the first-year deliverable for a multiyear U.S. Department of Energy-funded project, End-Use Load Profiles for the U.S. Building Stock, that intends to produce a set of highly resolved EULPs of the U.S. residential and commercial building stock. The project team, made up of researchers from the National Renewable Energy Laboratory (NREL), Lawrence Berkeley National Laboratory (LBNL), and Argonne National Laboratory, ultimately will use calibrated physics-based building energy models to create these EULPs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Method of Test for Evaluating Building Performance Simulation Software

ANSI/ASHRAE Standard 140 Method of Test for Evaluating Building Performance Simulation Software specifies the method to test the core competency of building performance simulation (BPS) software, a broad class of software which includes building energy modeling (BEM) software. Standard 140 has been widely used by BEM software vendors to help diagnose and compare the results from the program with other modeling programs. The Standard is also referenced by codes, standards, government programs, and other incentive programs as a part of minimum requirements for qualifying BEM software. The explanatory information, summary tables and figures in this 140 User’s Manual (referred to as “this Manual”) are provided to help users in implementing various suites of tests specified in Standard 140-2023 (referred to in this manual as “Standard 140” or “the Standard”).

97 MATHEMATICS AND COMPUTING↗

Lahaina Energy Partnership: Technical Assistance Task Updates and Discussion Part 2

The Lahaina Energy Partnership (LEP) is an initiative funded by the U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy (EERE) to support energy planning and rebuilding efforts in Hawaii's historic town of Lahaina on Maui as the community recovers from a devastating fire on August 8, 2023, with technical assistance provided by the National Laboratory of the Rockies. NLR has partnered with Hawaii-based community organizations to engage with Lahaina the community on energy priorities and inform the technical assistance scope. This virtual workshop presentation is the second in a two-part series to provide progress updates and request community input to guide next steps. Workshop 1 on November 18 focused on hydropower resource potential, building energy modeling, and workforce development. Workshop 2 on December 11 (this presentation) will focus on microgrids, electric grid hardening, policy and regulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Lahaina Energy Partnership: Technical Assistance Task Updates and Discussion Part 1 [Slides]

The Lahaina Energy Partnership (LEP) is an initiative funded by the U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy (EERE) to support energy planning and rebuilding efforts in Hawaii's historic town of Lahaina on Maui as the community recovers from a devastating fire on August 8, 2023, with technical assistance provided by the National Laboratory of the Rockies. NLR has partnered with Hawaii-based community organizations to engage with Lahaina the community on energy priorities and inform the technical assistance scope. This virtual workshop presentation is the first in a two-part series to provide progress updates and request community input to guide next steps. Workshop 1 on November 18 (this presentation) will focus on Hydropower resource potential, building energy modeling, workforce development. Workshop 2 on December 11 (presentation forthcoming) will focus on microgrids, electric grid hardening, policy and regulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impacts of Electric Space Heating in Multifamily Apartments in Juneau, Alaska [Slides]

The study objective was to understand the change in electrical consumption and cost after the addition of a ductless mini-split air-source heat pump (ASHP) across rental apartments heated by electrical resistance heating systems in multifamily buildings in Juneau, Alaska. Alaska Electric Light and Power Company (AELP), the utility in Juneau, Alaska, funded installation of 19 heat pumps across four buildings. Using electrical meter interval data, including the total apartment consumption and submeter data for each heating appliance (electric resistance baseboard and heat pump), the National Laboratory of the Rockies (NLR) calculated energy use metrics before and after heat pump installation and visualized results. Through this research, NLR compares electrical use (total and specific to heating appliances), adjusted for weather and apartment size, and electrical demand in the year before and after installation of an ASHP across study units. The results will inform the utility and residents of documented energy and cost savings from transitioning building heating systems to a higher-efficiency electricity-based appliance, deliver a basis for building energy modeling across other multifamily housing dwellings, and enable estimates of potential electricity savings to AELP grid under widespread adoption scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Benefits Of Automated Construction And Energy Efficiency Measures In Modular Homes

This article builds on and adds to a Buildings XV publication that introduced the Transformative Efficiency and Automation in Modular Homes (TEAMH) project. The TEAMH project sought to develop a scalable solution for producing modular homes with 20-50% energy savings and similar cost relative to site-fabricated single-family home construction. A key aspect of the project was assessing the potential for labor cost reductions through automation-assisted construction using light gauge steel (LGS). To quantify the advantages of this approach, side-by-side comparisons were made between traditional wood-framed construction and automation-assisted LGS construction. This demonstration involved constructing one wood-framed wall and several LGS test walls, accompanied by a time-and-motion study. The results indicated that automation assistance could decrease construction time and associated labor costs by as much as 46%. High-performance envelope technologies for exterior insulation and air sealing were evaluated to compare modular homes with site-built homes that meet the International Energy Conservation Code (IECC). A key technology considered was vacuum insulation panels (VIPs) with fiberglass cores. Guarded hot box testing of multiple full-scale wall assemblies containing different combinations of exterior continuous insulation systems containing phenolic foam and VIPs. Testing on various full-scale wall assemblies revealed that, with LGS construction, cavity insulation had minimal impact on exterior wall performance. Omitting cavity insulation can reduce labor and material costs while streamlining manufacturing, as its installation is labor-intensive and not easily automated due to the need for precise placement around wiring and other internal components. Guarded hot box tests of multiple LGS test walls with foam and VIP-based exterior insulation systems achieved R-values of up to 31 hr-ft2-°F/Btu. Finally, building energy modeling of multiple modular home designs indicated that the upgraded envelope assemblies can yield heating energy savings of up to 50% and cooling energy savings of up to 30% compared to IECC 2018 standards.

Shrestha, Som [ORNL] (ORCID:0000000183993797)↗

Flexible Reinforcement Learning Framework for Building Control using EnergyPlus-Modelica Energy Models

In recent years, reinforcement learning (RL) methods have been greatly enhanced by leveraging deep learning approaches. RL methods applied to building control have shown potential in many applications due to their ability to complement or replace conventional methods such as model-based or rule-based controls. However, RL-based building control software is likely tailored either to one target building system or to a specific RL method so that significant additional effort would be required to customize the RL-based controller for use in other building systems or with other RL approaches. Also, RL-based building controls usually depend on building energy simulations to train controllers, so emulating building dynamics (i.e., thermal dynamics and control dynamics) and capturing sub-hourly dynamic profiles are crucial to further the development of effective RL-based building control methods. To address these challenges, we present an open source RL-based control software employing a high-fidelity hybrid EnergyPlus-Modelica building energy model which emulates building dynamics at 1-minute resolution. This software consists of decoupled components (environment, building emulator, control agent, and RL algorithm), which allows for quick prototyping and benchmarking of standard RL algorithms in different systems; for example, a single component can be replaced without revising all of the software. To demonstrate this software framework, we conducted a benchmark study using an EnergyPlus-Modelica building energy model for a Chicago office building with an RL-based controller to dynamically control the chilled water temperature setpoint and the air handling unit supply air temperature setpoint on selected floors.

Lee, Joon-Yong↗

Artificial Intelligence for Enhancing Multiscale Analysis: Buildings Focus

This project aims to develop multi-scale building energy data, potentially improving the representation of the U.S. buildings sector in GCAM-USA, an U.S.-focused human-energy-Earth systems model. Existing building energy datasets are typically limited to national or regional levels, which constrains the ability of models to capture fine-scale human-energy-Earth systems interactions and reduces their relevance for decision-making on issues such as energy security, resilience, and energy planning. By leveraging AI and advanced data integration methods, this work fuses multiple existing datasets to enhance the physical and geographic representation of both residential and commercial building energy use. So far, progress includes processing residential building data, designing the data structure for commercial buildings, and testing AI approaches for integrating datasets and addressing spatial-temporal gaps. This effort can not only advances GCAM-USA’s capability in modeling the buildings sector but also supports broader DOE missions, such as developing digital testbeds, enhancing grid resilience analysis, and improving building–energy system modeling at decision-relevant scales.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development of new baseline models for U.S. medium office buildings based on commercial buildings energy consumption survey data

Building energy estimation for the building sector under various scenarios are needed for building energy regulation and policy making. This often starts with representative baselines (either empirical baseline or modeled baseline). Commercial Buildings Energy Consumption Survey (CBECS) data is a widely used empirical baseline for U.S. commercial buildings, but none of the existing baseline model are developed to represent the CBECS data. This paper aims to develop new baseline models for the U.S. medium office buildings, which can produce modeled baselines consistent with the CBECS data. Here, we introduced the methodology to create baseline models and the criteria to evaluate the performance of baseline models. The methodology consists of three phases: (1) identification of model inputs, (2) model calibration, and (3) model validation with uncertainty analysis. The evaluation index is the coefficient of variation of the root-mean-square deviation (CV(RMSD)) of site energy use intensities (EUIs) between the modeled baseline and empirical baseline. Then 30 new baseline models for two vintages (pre- and post-1980) and 15 climate zones were created. The evaluation shows that the CV(RMSD) is lower than 0.05 for the modeled baselines produced by the new baseline models. As a comparison, the CV(RMSD) is higher than 0.1 for the existing modeled baselines generated by DOE Commercial Reference Building Models. Further analysis shows that the new baseline models are able to capture the uncertainties of the representative features of existing buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stochastic simulation of occupant-driven energy use in a bottom-up residential building stock model

The residential buildings sector is one of the largest electricity consumers worldwide and contributes disproportionally to peak electricity demand in many regions. Strongly driven by occupant activities, household energy consumption is stochastic and heterogeneous in nature. However, most residential energy models applied by industry use homogeneous, deterministic activity schedules, which work well for predictions of annual energy consumption, but can result in unrealistic hourly or sub-hourly electric load profiles, with exaggerated or muted peaks. The increasing proportion of variable renewable energy generators means that representing the heterogeneity and stochasticity of occupant behavior is now crucial for reliable planning at both bulk-power and distribution-system scales. This work presents a novel and open-source occupancy simulation approach that can simulate a diverse set of individual occupant and household event schedules for all major electricity, fuel, and hot water end uses. To accomplish this, we evaluated three alternative occupant activity simulation approaches before selecting a hybrid combining time-inhomogeneous Markov chains and probability-sampling of event durations and magnitudes. Further, we integrated the stochastic occupancy simulation with an open-source bottom-up physics-simulation building stock model and published a set of 550,000 diverse household end-use activity schedules representing a national housing stock. The simulator was verified against time-use survey data, and simulation results were validated against measured end-use electricity data for accuracy and reliability. While we use data for the United States, our application demonstrates how similar approaches could be applied using the time-use survey data collected in many countries around the world.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗