Search NASA⌕ Search

SEARCH · Search NASA

Results for “CADMIUM TELLURIDE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

First Year PIDDP Report on gamma-ray and x-ray spectroscopy: X-ray remote sensing and in situ spectroscopy for planetary exploration missions and gamma-ray remote sensing and in situ spectroscopy for planetary exploration missions

Detectors that will be used for planetary missions must have their responses calibrated in a reproducible manner. In addition, it is important to characterize a detector system at uneven portions of its life cycle, for example after exposure to different amounts of radiation. A calibration and response characterization facility has been constructed at Schlumberger-Doll Research for all types of gamma- and x-ray detectors that may be used for planetary measurement. This facility is currently being tested. Initial use is expected for the MARS 94 detectors. The facility will then also be available for calibrating other detectors as well as arrays of detectors such as the NEAR detector with its central Nal(TI) crystal surrounded with a large BGO crystal. Cadmium telluride detectors are investigated for applications in space explorations. These detectors show an energy resolution of 5 keV for the 122 keV 57Co line. Earlier reported polarization effects are not observed. The detectors can be used at temperatures up to 100 C, although with reduced energy resolution. The thickness of standard detectors is limited to 2 mm. These detectors become fully efficient at bias voltages above 200 V. Initial results for a 1 cm thick detector show that the quality of the material is inferior to the thinner standard detectors and hole trapping affects the pulse height. A detailed characterization of the detector is in progress. Prototypes of photomultipliers based on a Channel Electron Multiplier (CEM) are being built to study their performance. Such photomultipliers promise better timing characteristics and a higher dynamic range while being more compact and of lower in weight.

Mahdavi, M.↗

Thermographic imaging for high-temperature composite materials: A defect detection study

The ability of a thermographic imaging technique for detecting flat-bottom hole defects of various diameters and depths was evaluated in four composite systems (two types of ceramic matrix composites, one metal matrix composite, and one polymer matrix composite) of interest as high-temperature structural materials. The holes ranged from 1 to 13 mm in diameter and 0.1 to 2.5 mm in depth in samples approximately 2-3 mm thick. The thermographic imaging system utilized a scanning mirror optical system and infrared (IR) focusing lens in conjunction with a mercury cadmium telluride infrared detector element to obtain high resolution infrared images. High intensity flash lamps located on the same side as the infrared camera were used to heat the samples. After heating, up to 30 images were sequentially acquired at 70-150 msec intervals. Limits of detectability based on depth and diameter of the flat-bottom holes were defined for each composite material. Ultrasonic and radiographic images of the samples were obtained and compared with the thermographic images.

Roth, Don J.↗

Evaluation of Temperature Gradient in Advanced Automated Directional Solidification Furnace (AADSF) by Numerical Simulation

A numerical model of heat transfer using combined conduction, radiation and convection in AADSF was used to evaluate temperature gradients in the vicinity of the crystal/melt interface for variety of hot and cold zone set point temperatures specifically for the growth of mercury cadmium telluride (MCT). Reverse usage of hot and cold zones was simulated to aid the choice of proper orientation of crystal/melt interface regarding residual acceleration vector without actual change of furnace location on board the orbiter. It appears that an additional booster heater will be extremely helpful to ensure desired temperature gradient when hot and cold zones are reversed. Further efforts are required to investigate advantages/disadvantages of symmetrical furnace design (i.e. with similar length of hot and cold zones).

Bune, Andris V.↗

Advanced Propulsion Power Distribution System for Next Generation Electric/Hybrid Vehicle: Preliminary System Studies - Phase 1

The report essentially summarizes the work performed in order to satisfy the above project objective. In the beginning, different energy storage devices, such as battery, flywheel and ultra capacitor are reviewed and compared, establishing the superiority of the battery. Then, the possible power sources, such as IC engine, diesel engine, gas turbine and fuel cell are reviewed and compared, and the superiority of IC engine has been established. Different types of machines for drive motor/engine generator, such as induction machine, PM synchronous machine and switched reluctance machine are compared, and the induction machine is established as the superior candidate. Similar discussion was made for power converters and devices. The Insulated Gate Bipolar Transistor (IGBT) appears to be the most superior device although Mercury Cadmium Telluride (MCT) shows future promise. Different types of candidate distribution systems with the possible combinations of power and energy sources have been discussed and the most viable system consisting of battery, IC engine and induction machine has been identified. Then, HFAC system has been compared with the DC system establishing the superiority of the former. The detailed component sizing calculations of HFAC and DC systems reinforce the superiority of the former. A preliminary control strategy has been developed for the candidate HFAC system. Finally, modeling and simulation study have been made to validate the system performance. The study in the report demonstrates the superiority of HFAC distribution system for next generation electric/hybrid vehicle.

Bose, Bimal K.↗

The Influence of a Rotating Magnetic Field on Solidification from a Traveling Solvent Zone

Application of a high frequency rotating magnetic field (50-400Hz) (RMF) with a strength of the order of 1 mT can be used to influence the fluid flow in an electrically conductive melt. The advantage of the RMF during the traveling solvent zone method for growth of semiconductor materials will be discussed. Preliminary modeling results for cadmium telluride growth from a tellurium solvent zone will be discussed.

Gillies, Donald C.↗

Modeling of Thermal Field in 'Contactless' Physical Vapor Transport

A numerical model of the thermal field in the furnace-ampoule system developed for the 'contactless' Physical Vapor Transport growth geometry is presented. The model is used to assess the effect of the system geometry and growth parameters on the conditions of 'contactless' growth of cadmium telluride crystals.

Palosz, W.↗

Experiment 1: Orbital Processing of High-Quality Zn-Alloyed CdTe Compound Semiconductors

Zinc-alloyed cadmium telluride (Zn:CdTe) crystals were grown in unit gravity and in microgravity for comparative analysis. Two crystals were grown on USML-1/STS-50 in 1992, and two additional crystals were grown on USML-2/STS-73 in 1995. The Crystal Growth Furnace (CGF) in the seeded Bridgman-Stockbarger crystal growth geometry was utilized on both missions. Crystals grown on USML-1/STS-50 were found to have solidified with partial wall contact due to the near-absence of the hydrostatic pressure in microgravity, a residual g-vector that was not axial, and the nonwetting sample/ampoule wetting conditions. Crystals grown on USML-2/STS-73 included: a sample/ampoule identical to the USML-1/STS-73 sample/ampoule, with the addition of a restraining spring to simulate hydrostatic pressure internally, and a tapered ampoule which accomplished 2.2 cm of crystal growth without wall contact. Infrared transmission of all ground and flight samples was found to be 63-66 percent, very close to the theoretical 66 percent, suggesting good stoichiometric control. Infrared microscopy confirmed that the primary precipitates were Te and their size (1-10 microns) and density suggested that the flight- and ground-base samples experienced similar thermal histories. Longitudinal macrosegregation, calculated using scaling analysis, was predicted to be low. Nearly diffusion controlled growth was achieved even in unit gravity and macrosegregation data could be fit with a diffusion controlled model. Radial segregation was monitored and was found to vary with fraction solidified, particularly through the shoulder region, where the sample cross section was varying significantly. It was also disturbed in the flight samples in regions where asymmetric wall contact was noted. In regions where a steady state was established, the radial segregation was invariant within our experimental measurement error. Flight samples were found to be much higher in structural perfection than samples processed in unit gravity under identical growth conditions. In regions where solidification had occurred without wall contact, the free surfaces evidenced virtually no twinning, although twins appeared in the flight samples in regions of wall contact and were pervasive in the ground samples. These results were confirmed using optical microscopy and synchrotron x-ray white beam topography. Full-width half-maximum rocking curve widths (FWHM), recorded in arc-seconds, were significantly reduced from 20 a-s (1 g) to 9 a-s (micro-g) for the best regions of the crystals. The 9 a-s (FWHM) rocking curve value in the unconfined flight samples equals the best value reported terrestrially for this material. The ground samples exhibited a fully developed (111)[110] dislocation mosaic structure, whereas dislocations within the flight samples were discrete and no mosaic structure was evident. The defect density was quantitatively reduced from 75,000 (1 g) to 800 (micro-g) +/-50 percent. Dislocation etch pit density results were confirmed using transmission synchrotron white beam and monochromated beam topography. The low defect density is thought to have resulted from the near absence of hydrostatic pressure, which allowed the molten boule to solidify with little or no wall contact. This minimized the transfer of hoop stresses during solidification and post-solidification processing.

Larson, D. J., Jr.↗

Quantitative Computer Tomography for Determining Composition of Microgravity and Ground Based Solid Solutions

Advances in x-ray Computer Tomography (CT) have been led by the medical profession, and by evaluation of industrial products, particularly castings. Porosity can readily be determined as a function of the density of a material, and CT is thus an industrially important NDE tool. Providing high purity, 100% dense standards of pure elements and compounds can be fabricated, the composition of solid solution alloys can be determined by measuring the CT number, which is a function of the absorption of the sample. Average densities across slices 1 mm thick can generally be determined to better than 1 percent. With present technology this spatial sensitivity is less than ideal, but important benefits can nevertheless be obtained by using CT, particularly single crystals, prior to making any destructive assault upon the sample. The sample can in fact be examined prior to removal from the mold within which it has been grown and, in the cases of microgravity flight samples, before removal from the cartridge assembly. This greatly assists the researcher in the characterization of the products, particularly as a guide to cutting and sampling. Examples of work with germanium-silicon alloys and mercury cadmium telluride taken with a radioactive cobalt source will be demonstrated.

Gillies, D. C.↗

Computed Tomography Support for Microgravity Materials Science Experiments

The accurate measurement of density in both liquid and solid samples is of considerable interest to Principal Investigators with materials science experiments slated for the ISS. The work to be described is an innovative application of a conventional industrial nondestructive evaluation instrument. Traditional applications of industrial computed tomography (CT) rely on reconstructing cross sections of large structures to provide two-dimensional planar views which can identify defects such as porosity, or other material anomalies. This has been done on microgravity materials science experiments to check the integrity of ampoule-cartridge assemblies for safety purposes. With a substantially monoenergetic flux, as can be obtained with a radioactive cobalt source, there will be a direct correlation between absorption and density. Under such conditions it then becomes possible to make accurate measurements of density throughout a sample, and even when the sample itself is enclosed within a furnace and a safety required cartridge. Such a system has been installed at Kennedy Space Center (KSC) and is available to PIs to examine samples before and after flight. The CT system is being used to provide density information for two purposes. Firstly, the determination of density changes from liquid to solid is vital information to the PI for purposes of modeling the solidification behavior of his sample, and to engineers who have to design containment ampoules and must allow for shrinkage and other volume changes that may occur during processing. While such information can be obtained by pycnometric measurements, the possibility of using a furnace installed on the CT system enables one to examine potentially dangerous materials having high vapor pressures, while not needing visible access to the material. In addition, uniform temperature can readily be obtained, and the system can be controlled to ramp up, hold, and ramp down while collecting data over a wide range of parameters automatically. Results of initial tests on low melting point elements such as gallium, indium and tin will be presented, and the intent is to proceed to compounds such as InSb, HgCdTe and CdTe. Alloys such as Pb-Sb (PI - Poirier, U AZ) and Cu-Al (PI - Trivedi, Ames Lab.), which are the subjects of flight experiments, will also be examined. The second application is the conversion of measured density values directly to composition. This was successfully done with the mercury cadmium telluride alloys grown on the second and fourth United States Microgravity Payload (USMP-2 and USMP-4) missions by Lehoczky. CdTe values along the length of the boules were obtained at KSC prior to cutting the sample, and could have been obtained prior to its removal from the cartridge and ampoule. Examples of the data obtained will be shown. It is anticipated that several of the materials science PIs will avail themselves of the technique described, initially for determining densities prior to flight, and then to acquire early quantitative data on the compositional variation within their samples.

Gillies, Donald C.↗

The Effect of the Wall Contact and Post-Growth Cool-Down on Defects in CdTe Crystals Grown by 'Contactless' Physical Vapour Transport

A series of cadmium telluride crystals grown by physical vapor transport without contact with the ampoule walls and cooled at different rates were characterized using synchrotron X-ray topography, photoluminescence, and chemical etching. Strain from sticking to silica glass and its effect on the dislocation density is shown. It was found that very fast cool-down increases dislocation density by at least one order of magnitude. None of the samples had random dislocation distributions but coarse clumping of dislocations on the scale of more than 100 microns was more prevalent in slowly cooled crystals. Photoluminescence revealed that slow cooling favored the donor-acceptor luminescence involving complex A centers. This was diminished in fast cooled material; and effect presumed to be due to dislocation gettering. Fast cooling also enhanced the formation of shallow acceptors. Implications for Bridgman growth of CdTe and the vapor growth of CdZnTe are discussed briefly.

Palosz, W.↗

THIS: A Next Generation Tuneable Heterodyne Infrared Spectrometer for SOFIA

A new infrared heterodyne instrument has been developed which allows the use of both tuneable diode lasers (TDL) and quantum cascade lasers (QCL) as local oscillators (LO). The current frequency tuning range of our system extends from 900 to 1100/cm depending on the availability of lasers but is planned to be extended to 600/cm soon. The IF-bandwidth is 1.4 GHz using an acousto-optical spectrometer (AOS). The frequency resolution and stability of the system is approximately 10(exp 7). Currently, mercury-cadmium-telluride (MCT) detectors are used as mixers while new devices like quantum-well-infrared-photodetectors (QWIP) and hot-electron-bolometers (HEB) are investigated. The IF-bandwidth can be extended to about 3 GHz by using a new broadband acousto-optical spectrometer presently under development. The instrument is fully transportable and can be attached to any infrared or optical telescope. The semiconductor laser is stabilized to a Fabry-Perot ring-resonator, which is also used as an efficient diplexer to superimpose the local-oscillator and the signal radiation. As a first step measurements of trace gases in Earth's atmosphere and non-LTE emission from Venus' atmosphere were carried out as well as observations of molecular features in sunspots. Further astronomical observations from ground-based telescopes and the airborne observatory SOFIA are planned for the future. Of particular interest are molecules without a permanent dipole moment like H2, CH4, C2H2 etc.

Sonnabend, Guido↗

Thermal System Verification and Model Validation for NASA's Cryogenic Passively Cooled James Webb Space Telescope (JWST)

A thorough and unique thermal verification and model validation plan has been developed for NASA s James Webb Space Telescope. The JWST observatory consists of a large deployed aperture optical telescope passively cooled to below 50 Kelvin along with a suite of several instruments passively and actively cooled to below 37 Kelvin and 7 Kelvin, respectively. Passive cooling to these extremely low temperatures is made feasible by the use of a large deployed high efficiency sunshield and an orbit location a! !he L2 Lagrange p~in!. Another enabling feature is the scale or size of the observatory that allows for large radiator sizes that are compatible with the expected power dissipation of the instruments and large format Mercury Cadmium Telluride (HgCdTe) detector arrays. This passive cooling concept is simple, reliable, and mission enabling when compared to the alternatives of mechanical coolers and stored cryogens. However, these same large scale observatory features, which make passive cooling viable, also prevent the typical flight configuration fully-deployed thermal balance test that is the keystone to most space missions thermal verification plan. JWST is simply too large in its deployed configuration to be properly thermal balance tested in the facilities that currently exist. This reality, when combined with a mission thermal concept with little to no flight heritage, has necessitated the need for a unique and alternative approach to thermal system verification and model validation. This paper describes the thermal verification and model validation plan that has been developed for JWST.

Parrish, Keith↗

Thermal System Verification and Model Validation for NASA's Cryogenic Passively Cooled James Webb Space Telescope

A thorough and unique thermal verification and model validation plan has been developed for NASA s James Webb Space Telescope. The JWST observatory consists of a large deployed aperture optical telescope passively cooled to below 50 Kelvin along with a suite of several instruments passively and actively cooled to below 37 Kelvin and 7 Kelvin, respectively. Passive cooling to these extremely low temperatures is made feasible by the use of a large deployed high efficiency sunshield and an orbit location at the L2 Lagrange point. Another enabling feature is the scale or size of the observatory that allows for large radiator sizes that are compatible with the expected power dissipation of the instruments and large format Mercury Cadmium Telluride (HgCdTe) detector arrays. This passive cooling concept is simple, reliable, and mission enabling when compared to the alternatives of mechanical coolers and stored cryogens. However, these same large scale observatory features, which make passive cooling viable, also prevent the typical flight configuration fully-deployed thermal balance test that is the keystone to most space missions thermal verification plan. JWST is simply too large in its deployed configuration to be properly thermal balance tested in the facilities that currently exist. This reality, when combined with a mission thermal concept with little to no flight heritage, has necessitated the need for a unique and alternative approach to thermal system verification and model validation. This paper describes the thermal verification and model validation plan that has been developed for JWST. The plan relies on judicious use of cryogenic and thermal design margin, a completely independent thermal modeling cross check utilizing different analysis teams and software packages, and finally, a comprehensive set of thermal tests that occur at different levels of JWST assembly. After a brief description of the JWST mission and thermal architecture, a detailed description of the three aspects of the thermal verification and model validation plan is presented.

Cleveland, Paul E.↗

CF2 Detection in Radio-Frequency Ar/CHF3 Plasmas by Fourier Transform Infrared Spectroscopy

CFx radicals, in particular CF2, are instrumental in anisotropic etching of SiO2. In order to optimize the CFx radical population in a given process environment, it is imperative that we understand their production mechanism. Towards this goal, we have conducted a series of quantitative measurements of CF2 radicals in low pressure RF plasmas similar to those used in SiO2 etching. In this study, we present preliminary results for Ar/CHF3 plasmas operating at pressures ranging from 10-50 mTorr and powers ranging from 100-500 W in the GEC reference cell, modified for inductive (transformer) coupling. Fourier transform infrared (FTIR) spectroscop) is used to observe the absorption features of the CF2 radical in the 1114 cm-1 and 1096 cm-1 spectral regions. The FTIR spectrometer is equipped with a high-sensitivity mercury cadmium telluride (MCT) detector and has afixed resolution of 0.125 cm- 1. The CF2 concentrations are measured for a range of operating pressures and discharge power levels, and are compared to measurements of the relative CF2 concentrations made by mass spectrometry using the method of appearance potential for radical selectivity.

Kim, J. S.↗

Microstructured Optical Fiber for X-ray Detection

A novel scintillating optical fiber is presented using a composite micro-structured quartz optical fiber. Scintillating materials are introduced into the multiple inclusions of the fiber. This creates a composite optical fiber having quartz as a cladding with an organic scintillating material core. X-ray detection using these fibers is compared to a collimated cadmium telluride (CdTe) detector over an energy range from 10 to 40 keV. Results show a good correlation between the fiber count rate trend and that of the CdTe detector.

DeHaven, Stanton L.↗

The ART-XC Instrument on Board the SRG Mission

Spectrum Roentgen Gamma (SRG) is an X-ray astrophysical observatory, developed by Russia in collaboration with Germany. The mission will be launched in 2014 from Baikonur, by a Zenit rocket with a Fregat booster and placed in a 6-month-period halo orbit around L2. The scientific payload consists of two independent telescopes . a soft-x-ray survey instrument, eROSITA, being provided by Germany and a medium-x-ray-energy survey instrument ART-XC being developed by Russia. ART-XC will consist of seven independent, but co-aligned, telescope modules with seven corresponding cadmium-telluride focal plane detectors. Each will operate over the approximate energy range of 6- 30 keV, with an angular resolution of <1 ', a field of view of ~30 ' and an energy resolution about 10% at 14 keV. The NASA Marshall Space Flight Center (MSFC) will fabricate some of the mirror modules, to complement others fabricated by VNIIEF in Russia.

Pavlinksy, M.↗

Towards an Imaging Mid-Infrared Heterodyne Spectrometer

We are developing a concept for a compact, low-mass, low-power, mid-infrared (MIR; 5- 12 microns) imaging heterodyne spectrometer that incorporates fiber optic coupling, Quantum Cascade Laser (QCL) local oscillator, photomixer array, and Radio Frequency Software Defined Readout (RFSDR) for spectral analysis. Planetary Decadal Surveys have highlighted the need for miniaturized, robust, low-mass, and minimal power remote sensing technologies for flight missions. The drive for miniaturization of remote sensing spectroscopy and radiometry techniques has been a continuing process. The advent of MIR fibers, and MEMS techniques for producing waveguides has proven to be an important recent advancement for miniaturization of infrared spectrometers. In conjunction with well-established photonics techniques, the miniaturization of spectrometers is transitioning from classic free space optical systems to waveguide/fiber-based structures for light transport and producing interference effects. By their very nature, these new devices are compact and lightweight. Mercury-Cadmium-Telluride (MCT) and Quantum Well Infrared Photodiodes (QWIP) arrays for heterodyne applications are also being developed. Bulky electronics is another barrier that precluded the extension of heterodyne systems into imaging applications, and our RFSDR will address this aspect.

Hewagama, T.↗

Fast, High-Precision Readout Circuit for Detector Arrays

The GEO-CAPE mission described in NASA's Earth Science and Applications Decadal Survey requires high spatial, temporal, and spectral resolution measurements to monitor and characterize the rapidly changing chemistry of the troposphere over North and South Americas. High-frame-rate focal plane arrays (FPAs) with many pixels are needed to enable such measurements. A high-throughput digital detector readout integrated circuit (ROIC) that meets the GEO-CAPE FPA needs has been developed, fabricated, and tested. The ROIC is based on an innovative charge integrating, fast, high-precision analog-to-digital circuit that is built into each pixel. The 128×128-pixel ROIC digitizes all 16,384 pixels simultaneously at frame rates up to 16 kHz to provide a completely digital output on a single integrated circuit at an unprecedented rate of 262 million pixels per second. The approach eliminates the need for off focal plane electronics, greatly reducing volume, mass, and power compared to conventional FPA implementations. A focal plane based on this ROIC will require less than 2 W of power on a 1×1-cm integrated circuit. The ROIC is fabricated of silicon using CMOS technology. It is designed to be indium bump bonded to a variety of detector materials including silicon PIN diodes, indium antimonide (InSb), indium gallium arsenide (In- GaAs), and mercury cadmium telluride (HgCdTe) detector arrays to provide coverage over a broad spectral range in the infrared, visible, and ultraviolet spectral ranges.

Rider, David M.↗