Search NASA⌕ Search

SEARCH · Search NASA

Results for “CHROMATOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Chemometric optimisation of pressurised liquid extraction for the determination of alliin and S‐allyl‐cysteine in giant garlic ( Allium ampeloprasum L.) by liquid chromatography tandem mass spectrometry

Abstract Introduction Giant garlic is a functional food that contains different kinds of bioactive molecules with beneficial effects on chronic noncommunicable diseases like diabetes and cardiovascular conditions. Considering biosynthesis pathways, abundance, and biological activity, alliin and S‐allyl‐cysteine were used as chemical markers of organosulphur compounds present in giant garlic. Objective To establish a chemometric optimisation of pressurised liquid extraction for the determination of alliin and S‐allyl‐cysteine in giant garlic by liquid chromatography tandem mass spectrometry (LC–MS/MS). Methodology Samples were blanched (ca. 90°C for 10 min) to inactivate alliinase and γ‐glutamyl transpeptidase enzymes and then freeze‐dried. Chemometric optimisation was performed via response surface methodology based on central composite design (CCD). Organosulphur compound yields were determined applying a validated LC–MS/MS method in multiple reaction monitoring (MRM) mode using the following transitions: for alliin m/z 178 → 74 and for S‐allyl‐cysteine m/z 162 → 41. Results According to CCD results, under constant conditions of pressure (1500 psi) and time (20 min), the optimal conditions for pressurised liquid extraction of alliin and S‐allyl‐cysteine were 70.75 and 68.97% v/v of ethanol in extraction solvent and 76.45 and 98.88°C as extraction temperature, respectively. Multiple response optimisation for the simultaneous extraction of both organosulphur compounds was established via desirability function. Under these conditions, 2.70 ± 0.27 mg g −1 dry weight (DW) of alliin and 2.79 ± 0.22 mg g −1 DW of S‐allyl‐cysteine were extracted. Conclusions These results clearly demonstrated that pressurised liquid extraction is an efficient green technique to extract bioactive organosulphur compounds from giant garlic. Extraction yields were significantly ( p < 0.05) higher than those obtained with conventional ultra‐turrax extraction.

Peterssen‐Fonseca, Darlene↗

Identification of Blue Discoloration in PBX 9404 using Ultrahigh Pressure Liquid Chromatography with Quadrupole Time-of-Flight Mass Spectrometry

PBX 9404, composed of 94 wt% HMX (1,3,5,7-Tetranitro-1,3,5,7-tetrazoctane), 3 wt% NC (nitrocellulose), 2.9 wt% CEF (tris(beta-chloroethyl) phosphate) and 0.1 wt% DPA (diphenylamine), has often been observed with a slight to entire blue discoloration of the manufactured prills. This blue discoloration has been observed since the formulation development of PBX 9404 in the late 1950s. In order to determine the source of the blue discoloration in PBX 9404, ultraviolet/visible (UV/Vis) absorbance of PBX 9404 and two potential candidates for the discoloration, p-nitrosodiphenylamine (p-NDPA) and N-nitrosodiphenylamine (N-NDPA) were evaluated. An absorbance band at 590 nm in PBX 9404 sample was attributed to the blue discoloration while p-NDPA and N-NPDA had different absorbance bands. Using the knowledge gained from the UV/Vis analysis, a semi-targeted approach using ultrahigh pressure liquid chromatography coupled to UV/Vis detector and quadrupole time of flight mass spectrometry (UHPLC-UV/Vis-QTOF) was implemented. Investigating the UHPLC-UV/Vis-QTOF chromatograms at a wavelength of 590 nm, a single compound was tentatively identified as being the source of the blue discoloration. Targeted tandem mass spectrometry (MS/MS) on the compound and subsequent analysis indicated that 4,4 -{[4-(Phenylimino)-2,5-cyclohexadien-1-ylidene]methylene}bis(N-phenylaniline), also known as Spirit Blue Base, was the source of the blue discoloration, which was confirmed using a standard. Here, a theory on the formation of Spirit Blue Base in PBX 9404 involving DPA, nitric acid (HNO 3 ) / nitrogen oxide(s) NO x , and formaldehyde is proposed.

36 MATERIALS SCIENCE↗

Liquid Chromatography Mass Spectrometry study of eutectic bis(2,2-dinitropropyl) acetal/formal

This study is the first attempt to document methodology development undergone using liquid chromatography tandem quadrupole time of flight mass spectrometry (LC-QTOF) to investigate degradation products of eutectic bis(2,2-dinitropropyl) acetal/formal nitroplasticizer (called NP here). Method properties investigated are: desolvation temperature (°C) and spray voltage (V) of the electrospray ionization source, and the development of an acetone system rinse to prevent any residual contamination between sample injections. Details are given on why it is essential to investigate method optimization with changes shown in MS/MS analysis in addition to MS results. Trends in MS/MS analytic results reveal important relationships between baseline and aged materials. In addition to verification of previously proposed fragments, insights offered by this newly developed methodology will also identify new degradation products and shed light on the complexity of NP degradation chemistry.

36 MATERIALS SCIENCE↗

Trace Compound Analysis in TATB by Liquid Chromatography coupled with Spectroscopic and Spectrometric Detection

Accurate quantitation of 1,3,5-triamino-2,4,6-trinitrobenzene (TATB) is important because of its strategic use as an energetic material. A purity determination is also needed for the proper assessment of performance. A fast and sensitive method has been developed to measure the purity of TATB in polymer-bonded materials. The target material is extracted with DMSO, and the extract is separated on a reversed-phase chromatography column. The column effluent is monitored by diode array detection (DAD) at 354 nm. The characteristic UV-Vis response and retention time identify the individual components when compared to pure compound standards. The chemical structures of compounds with no pure standards available have been determined by high-resolution mass spectrometry (MS) and MS/MS. The major component, TATB, along with 1-chloro-3,5-dinitro-2,4,6-triaminobenzene (T4A) and mono-benzofuroxan (FX1) were quantitated directly from pure compound standards. Several trace concentration components, mono-benzofurazan (F1), 1-bromo-3,5-dinitro-2,4,6-triaminobenzene (Br-T4A), 2,4,6-triamino-1-nitroso-3,5-dinitrobenzene (MN-TATB), 2,4,6-triamino-1-hydroxyl-3,5-dinitrobenzene (HO-TATB), and 2,4,6-triamino-1-nitrile-3,5-dinitrobenzene (Nitrile-TATB) were also detected and structures verified via MS/MS. Approximate concentrations were determined using calibrations from standards of similar structures. Additional trace components were also detected by MS. Contained herein are the results of analyses of TATB-based materials characterized for polymer-bonded formulations compared to different preparations of TATB. The accuracy, details, and process of developing this method are reported here.

36 MATERIALS SCIENCE↗

Trocylation of 3-quinuclidinol, a key marker for the chemical warfare agent 3-quinuclidinyl benzilate, for its enhanced detection at low levels in complex soil matrices by electron ionization gas chromatography–mass spectrometry

Detection of 3-quinuclidinol (3Q), a marker for the chemical warfare agent 3-quinuclidinyl benzilate, is very difficult by gas chromatography–mass spectrometry (GC/MS), providing low, broad signals even when analyzed in isolated form. Therefore, a method that can convert 3Q into a substrate with enhanced detectability by GC/MS would be an important tool for its analysis. 2,2,2-Trichloroethoxycarbonyl chloride (TrocCl) was used in the derivatization of 3Q in three different soils of varying composition and total organic content (Virginia type A soil, Nebraska EPA standard soil and Ottawa sand) when present at a 10 μg g -1 concentration in each. A direct derivatization protocol and one involving the pre-extraction of the analyte were evaluated for their individual efficiencies and subsequent analysis using electron ionization GC/MS. The practical derivatization of 3Q, when present at low levels (10 μg g -1 ) in three different soil matrices, was found to be rapid (1 h) and to take place smoothly at ambient temperature (and as low as 4°C). The method detection limit was determined to be 30 ng mL -1 for the Virginia type A soil, 49 ng mL -1 for the Nebraska EPA standard soil and 72 ng mL -1 for the Ottawa sand sample. An expedient and practical derivatization method for 3Q, a chemical warfare degradation product difficult to detect by GC/MS, has been realized using trichloroethyl chloroformate. The reaction provides 3Q-Troc, a derivative with better detectability than 3Q by electron ionization GC/MS such as peak sharpness and a unique mass spectrum for its unambiguous identification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi-Instrument Characterization of the Surfaces and Materials in Microfabricated, Carbon Nanotube-Templated Thin Layer Chromatography Plates. An Analogy to ‘The Blind Men and the Elephant’

Herein we apply a suite of surface/materials analytical tools to characterize some of the materials created in the production of microfabricated thin layer chromatography plates. Techniques used include X-ray photoelectron spectroscopy (XPS), valence band spectroscopy, static time-of-flight secondary ion spectrometry (ToF-SIMS) in both positive and negative ion modes, Rutherford backscattering spectroscopy (RBS), and helium ion microscopy (HIM). Materials characterized include: the Si(100) substrate with native oxide: Si/SiO2, alumina (35 nm) deposited as a diffusion barrier on the Si/SiO2: Si/SiO2/Al2O3, iron (6 nm) thermally evaporated on the Al2O3: Si/SiO2/Al2O3/Fe, the iron film annealed in H2 to make Fe catalyst nanoparticles: Si/SiO2/Al2O3/Fe(NP), and carbon nanotubes (CNTs) grown from the Fe nanoparticles: Si/SiO2/Al2O3/Fe(NP)/CNT. The Fe thin films and nanoparticles are found in an oxidized state. Some of the analyses of the CNTs/CNT forests reported appear to be unique: the CNT forest appears to exhibit an interesting ‘channeling’ phenomenon by RBS, we observe an odd-even effect in the ToF-SIMS spectra of Cn- species for n = 1 – 6, with ions at even n showing greater intensity than the neighboring signals, and ions with n ≥ 6 showing a steady decrease in intensity, and valence band characterization of CNTs using X-radiation is reported. The information obtained from the combination of the different analytical tools provides a more complete understanding of our materials than a single technique, which is analogous to the story of ‘The Blind Men and the Elephant’. (Of course there is increasing emphasis on the use of multiple characterization tools in surface and materials analysis.) The raw XPS and ToF-SIMS spectra from this study will be submitted to Surface Science Spectra for archiving.

Environmental Molecular Sciences Laboratory↗

Characterization of the homologs of flerovium with crown ether based extraction chromatography resins: studies in nitric acid

Eichrom’s Pb resin, a crown-ether-based extraction chromatography resin, was characterized for separation of the flerovium (Fl) homologs, Pb and Sn. Batch uptake of Pb(II) and Sn(IV) radionuclides was determined from an HNO 3 matrix. Pb(II) was strongly retained on the resin at all HNO 3 concentrations, while Sn(IV) showed no uptake. Extraction kinetics for Pb(II) were examined and show suitable uptake on the second time scale. Here, separation methods for the isolation of individual homologs, Pb(II) and Sn(IV), have been established using 2 mL pre-packed vacuum flow Pb resin columns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A chromatography chemistry for purifying $\mathrm{Pa}$ from $\mathrm{U-Nb}$ metal alloys

Here we present a chromatography chemistry for purifying protactinium from uranium metal alloys containing weight-percent concentrations of niobium. Niobium is precipitated in 9 M HCl without the co-precipitation of Pa as demonstrated by gamma-ray spectrometry. Protactinium is further purified using Bio-Rad™ anion resin AG® 1-X8 and 9 M HCl + 0.0128 M HF. A Pa/Nb separation factor of 85,000 and a 90% Pa recovery is demonstrated, which is amenable to 231 Pa concentration determination by isotope dilution and 231 Pa/ 235 U model age calculation for nuclear forensics.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Improving liquid chromatography-mass spectrometry sensitivity using a subambient pressure ionization with nanoelectrospray (SPIN) interface

In this work the Subambient Pressure Ionization with Nanoelectrospray (SPIN) ion source and interface which operates at ~15-30 Torr is demonstrated to be compatible with gradient reversed-phase liquid chromatography-MS applications, exemplified here with the analysis of complex samples (a protein tryptic digest and a whole cell lysate). A low liquid chromatographic flow rate (100-400 nL/min) allowed stable electrospray to be established while avoiding electrical breakdown. Efforts to increase the operating pressure of the SPIN source relative to previously reported designs prevented solvent freezing and enhanced charged cluster/droplet desolvation. A 5-12-fold improvement in sensitivity relative to a conventional atmospheric pressure nanoelectrospray ionization (ESI) source was obtained for detected peptides.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Size Exclusion Chromatography-Ion Mobility-Mass Spectrometry Coupling: a Step Toward Structural Biology

Noncovalent interactions are essential for the structural organization of biomacromolecules in cells. For this reason, the study of the biophysical, dynamic, and architectural interactions among biomacromolecules is essential. Since mass spectrometry requires compatible solutions while preserving the noncovalent bonding network, we envisioned that size exclusion chromatography coupled with ion mobility and mass spectrometry would be a valuable technique to desalt the initial sample and provide solution and gas-phase structural information in a single stage experiment. Such coupling allowed obtaining information on solution protein complex composition with SEC separation and on authenticity and purity with IMS-MS. Our study demonstrated that such coupling is compatible, useful, as well as suitable for a routine analysis, in pharmaceutical industry, for example. Mobility data were reliable and injected standards allowed calibrating the collision cross-section scale. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effective methylation of phosphonic acids related to chemical warfare agents mediated by trimethyloxonium tetrafluoroborate for their qualitative detection and identification by gas chromatography-mass spectrometry

The effective methylation of phosphonic acids related to chemical warfare agents (CWAs) employing trimethyloxonium tetrafluoroborate (TMO·BF 4 ) for their qualitative detection and identification by gas chromatography-mass spectrometry (GC-MS) is presented. The methylation occurs in rapid fashion (1 h) and can be conveniently carried out at ambient temperature, thus providing a safer alternative to the universally employed diazomethane-based methylation protocols. Optimization of the methylation parameters led us to conclude that methylene chloride was the ideal solvent to carry out the derivatization, and that even though methylated products can be observed surfacing after only 1 h, additional time was not found to be detrimental but beneficial to the process particularly when dealing with analytes at low concentrations (~10 μg mL -1 ). Due to its insolubility in methylene chloride, TMO·BF 4 conveniently settles to the bottom during the reaction and does not produce additional interfering by-products that may further complicate the GC-MS analysis. We demonstrated the method to successfully methylate a variety of Schedule 2 phosphonic acids, including their half esters, resulting in derivatives that were readily detected and identified using the instrument's spectral library. Most importantly, the method was shown to simultaneously methylate a mixture of the organophosphorus-based nerve agent hydrolysis products: pinacolyl methylphosphonate (PMPA), cyclohexyl methylphosphonate (CyMPA) and ethyl methylphosphonate (EMPA) (at a 10 μg mL - 1 concentration each) in a fatty acid ester-rich organic matrix (OPCW-PT-O 3 ) featured in the 38th Organisation for the Prohibition of Chemical Weapons (OPCW) Proficiency Test. Additionally, the protocol was found to effectively methylate N,N-diethylamino ethanesulfonic acid and N,N-diisopropylamino ethanesulfonic acid that are products arising from the oxidative degradation of the V-series agents VR and VX respectively. This work described herein represents the first report on the use of TMO·BF 4 as a viable, stable and safe agent for the methylation of phosphonic acids and their half esters and within the context of an OPCW Proficiency Test sample analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Beyond the wall: High-throughput quantification of plant soluble and cell-wall bound phenolics by liquid chromatography tandem mass spectrometry

Plants accumulate several thousand of phenolic compounds, including lignins and flavonoids, which are mainly synthesized through the phenylpropanoid pathway, and play important roles in plant growth and adaptation. A novel high-throughput ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method was established to quantify the levels of 19 flavonoids and 15 other phenolic compounds, including acids, aldehydes, and alcohols. The chromatographic separation was performed in 10 minutes, allowing for the resolution of isomers such as 3-, 4-, and 5-chlorogenic acids, 4-hydroxybenzoic and salicylic acids, isoorientin and orientin, and luteolin and kaempferol. The linearity range for each compound was found to be in the low fmol to the high pmol. Furthermore, this UHPLC-MS/MS approach was shown to be very sensitive with limits of detection between 1.5 attomoles to 300 fmoles, and limits of quantification between 5 attomoles to 1,000 fmoles. Extracts from maize seedlings were used to assess the robustness of the method in terms of recovery efficiency, matrix effect, and accuracy. The biological matrix did not suppress the signal for 32 out of the 34 metabolites under investigation. Additionally, the majority of the analytes were recovered from the biological samples with an efficiency above 75 %. All flavonoids and other phenolic compounds had an intra- and inter-day accuracy within a ± 20 % range, except for coniferyl alcohol and vanillic acid. Finally, the quantification of flavonoids, free and cell wall-bound phenolics in seedlings from two maize lines with contrasting phenolic content was successfully achieved using this methodology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated thermal extraction-desorption gas chromatography mass spectrometry: A multifunctional tool for comprehensive characterization of polymers and their degradation products

The TED-GC–MS analysis is a two-step method. A sample is first decomposed in a thermogravimetric analyzer (TGA) and the gaseous decomposition products are then trapped on a solid-phase adsorber. Subsequently, the solid-phase adsorber is analyzed with thermal desorption gas chromatography mass spectrometry (TDU-GC–MS). This method is ideally suited for the analysis of polymers and their degradation processes. A new entirely automated system is introduced which enables high sample throughput and reproducible automated fractioned collection of decomposition products. The fractionated collection together with low temperatures reduces the risk of contamination, improves instrumental stability and minimizes maintenance efforts. Through variation of the two main parameters (purge gas flow and heating rate) it is shown how the extraction process can be optimized. By measuring the decomposition products of polyethylene it is demonstrated that compounds with masses of up to 434 Da can be detected. This is achieved despite the low temperature (˜40 °C) of the solid-phase adsorber and the low thermal desorption temperature of 200 °C in the TDU unit. It is now shown that automated TED-GC–MS represents a new flexible multi-functional method for comprehensive polymer analyses. Comparable polymer characterization was previously only achievable through a combination of multiple independent analytical methods. This is demonstrated by three examples focused on practical challenges in materials analysis and identification: The first one is the analysis of wood plastic composites for which the decomposition processes of the polymer and the bio polymer (wood) could be clearly distinguished by fractionated collection using sequential adsorbers. Secondly, a fast quantitative application is shown by determining the weight concentrations of an unknown polyolefin blend through comparison with a reference material. Additionally, the determination of microplastic concentrations in environmental samples is becoming an increasingly important analytical necessity. It is demonstrated that with TED-GC–MS calibration curves showing good linearity for the most important precursors for microplastic, even complex matrix materials (suspended particulate matter) can be successfully analyzed.

36 MATERIALS SCIENCE↗

Influence of ion-pairing reagents on the separation of intact glycoproteins using hydrophilic-interaction liquid chromatography - high-resolution mass spectrometry

Hydrophilic-interaction liquid chromatography (HILIC) of intact proteins offers high-resolution separations of glycoforms of glycoproteins differing in the number of (neutral) glycans. However, to obtain efficient separations it is essential that the positively charged sites of the proteins are shielded by acidic (negative) ion-pair reagents (IPRs), so as to enhance the contribution of the hydroxyl groups of the (neutral) sugars in the glycoprotein. Here, we studied the influence of various IPRs that differ in physico-chemical properties, such as hydrophobicity and acidity, on the capillary-scale HILIC separation of intact (glyco)proteins. We evaluated the use of fluoroacetic acid (MFA), difluoroacetic acid (DFA), trifluoroacetic acid (TFA), and heptafluorobutyric acid (HFBA) as diluents for sample preparation, as solvents for sample loading on a reversed-phase trap prior to the HILIC separation, and as mobile-phase components for HILIC and HILIC-MS. To reduce the contribution of ion-exchange interaction with the (silica-based) stationary phase, we used an acrylamide-based monolithic column. We studied the influence of the different IPRs on each step of the separation of a mixture of proteins of different size and hydrophilicity and on the separation of the five glycoforms of ribonuclease B. The content of IPR in the sample was shown not to affect the separation and the MS detection. However, a low content of TFA and DFA in the mobile phase is favourable, as it reduces adduct formation and leads to higher signal intensity. The optimized HILIC conditions successfully resolved nine major glycoforms groups of a ~40 kDa glycoprotein horseradish peroxidase (HRP), as an example of a complex glycoprotein.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of different getter substrates using two-dimensional gas chromatography with time of flight mass spectrometry

We report while understanding hydrogen uptake by organic based getters such as 1,4-bis(phenylethynyl)benzene (DEB) combined with a palladium(0)bis(dibenzylideneacetone) (Pd(dba) 2 ) catalyst is essential, another crucial element to understand is the decomposition of the DEB, Pd(dba) 2 , and/or substrate material. The breakdown of these materials may create unwanted volatiles, which may interact with and lead to deterioration of sensitive materials. Moreover, it is critical to understand if different substrates cause the getter and/or catalyst to degrade in different manners. Utilizing comprehensive two-dimensional gas chromatography (GC×GC) with time-of-flight mass spectrometry (TOFMS), the presence of volatiles located in the headspace of various DEB/Pd(dba) 2 getter substrates is examined. These samples include a getter infused silicone foam, a hydrogenated getter infused silicone foam, an activated carbon getter pellet, and a hydrogenated activated carbon getter pellet. Application of Fisher ratio (F-ratio) analyses lead to the identification of several compounds that are generated or consumed through the hydrogenation process. These include benzene derivatives such as bibenzyl, benzaldehyde, and vinyl benzoate in the activated carbon pellets and 1,5-diphenyl-3-pentanone, toluene, styrene, and 1–1'(2-pentene 1,5-diyl)bis benzene in the silicone foams, and alkane/alkene derivatives such undecane, 4-tridecene, and decane in the activated carbon pellets and 2,6-dimethyl undecane in the silicone foams. Further comparison of the different hydrogenated getter substrates (e.g. activated carbon pellet and silicone foam) indicates that the different substrates alter the decomposition products created from the degradation of the DEB and Pd(dba) 2 .

47 OTHER INSTRUMENTATION↗

Use of Fisher's Ratio assisted multivariate curve resolution- alternating least squares for discovery-based analysis using ultrahigh pressure liquid chromatography-high resolution mass spectrometry

Non-targeted analysis of complex chemical mixtures can be difficult considering the convoluted nature of the matrix and the potential unknown chemical differences between samples or classes of samples. Ultrahigh pressure liquid chromatography coupled to quadrupole time-of-flight mass spectrometry (UHPLC-QTOF) is an ideal technique to probe chemical differences for a wide variety of samples. While UHPLC-QTOF can discover minute chemical differences down to low part per billion (ppb) concentrations with a high degree of confidence, the application of high-resolution mass spectrometry can yield massive amounts of information (∼ 10 gb per sample) that cannot be analyzed manually. Therefore, the application of chemometric techniques is mandatory for the interrogation of complex samples. Fisher's ratio (FR) assisted multivariate curve resolution-alternating least squares (MCR-ALS) was used to the discover and identify the chemical differences between two classes of materials: 1) a pond water matrix and 2) the matrix spiked with a pharmaceutical standard mix containing 17 compounds. Thirteen of the seventeen spiked compounds were discovered using FR analysis, and then five were successfully deconvoluted using MCR-ALS wherein the number of curves chosen were automatically determined using singular value decomposition (SVD). In conclusion, the use of an automated FR assisted MCR-ALS will aid in discovering trace levels of chemical components without the need for the researcher to provide potentially biased input which will aid in non-targeted workflow.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accelerating actinium-225 purification by high-pressure ion chromatography

Actinium-225 (t1/2 = 9.92 days) is an important radioisotope for targeted alpha therapy applications. The limited supply obtained through the decay of thorium-229 has motivated accelerator-based production routes, including irradiation of thorium targets. Irradiated targets can produce useful quantities of actinium-225, but the product requires final purification from chemically similar lanthanide contaminants. This work describes an automated high-pressure ion chromatography method for this final polishing step. The method uses a reusable strong-acid cation-exchange column bearing sulfonic acid functional groups. α-Hydroxyisobutyric acid (α-HIBA), adjusted to pH 4.3 with lithium hydroxide, complexes and elutes lanthanides, a dilute hydrochloric acid matrix-exchange step removes residual α-HIBA, and concentrated hydrochloric acid then elutes retained actinium(III). The protocol purified actinium-225 to >99% radiopurity across tracer-level samples and samples containing >150 µCi (5.6 MBq) of activity. A 10 min, 0.1 M hydrochloric acid matrix exchange substantially reduced organic eluent carryover, and in-line sodium iodide detection enabled real-time monitoring of actinium and lanthanide elution. The developed method can be completed in <1 h and provides a basis for automated purification workflows for accelerator-produced actinium-225.

Gaddis, Kevin [ORNL] (ORCID:0000000183398314)↗