Search NASA⌕ Search

SEARCH · Search NASA

Results for “CM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Astronomical infrared spectroscopy with a Connes-type interferometer. III Alpha Orionis, 2600 to 3450 per cm.

Analysis of recent spectra of alpha Ori in the 3 to 4 micron region at a resolving power of about 10,000, showing clear evidence of the delta v = 1 sequence of the rotation-vibration bands of OH. A detailed investigation of the rotational and vibrational populations suggests that the OH is close to being in LTE at an apparent temperature of 4100 plus or minus 200 K. An OH abundance of 1.2 x 10 to the 20th molecules per cu cm and upper limits for H2O and H super 35 Cl of 8 x 10 to the 18th and 8 x 10 to the 17th molecules per cu cm, respectively, are deduced. It is also deduced that the rms turbulence velocity in the region of OH line formation is 11.5 plus or minus 2 km/sec. The implications of these data on abundances in M supergiant atmospheres are discussed.

Beer, R.↗

Experimental measurements of 2.25-cm backscatter from sea surfaces.

Airborne 2.25-cm wavelength radar backscatter measurements of low-wind-speed sea conditions were obtained off the coast of Texas in January 1971. These data are compared with unpublished NASA 2.25-cm backscatter measurements recorded over the Atlantic in 1970. The two data sets were in general agreement and supported results previously reported by other authors which showed the absence of a saturation effect at this wavelength. Analyses of these data using computerized clustering techniques indicated that a wind speed measurement accuracy of 5-7 knots is an operational potential.

Newton, R. W.↗

Observations of Jupiter at 13-cm wavelength during 1969 and 1971.

Radio observations of Jupiter have been carried out at Goldstone, CA at a wavelength of 13 cm during the oppositions of 1969 and 1971. In 1969, circular-polarization and total-flux measurements were made with a 64-m radio telescope. From May through October 1971, Jupiter's flux density was measured at weekly intervals with a 26-m antenna. The upper limit to the degree of circular polarization over the longitude ranges 10-100 deg and 160-250 deg System III (1957.0) is 1%; the flux data have been used to derive a magnetospheric rotation period which is approximately 0.37 sec longer than the IAU System III (1957.0). The flux-density data define beaming curves which are apparently different from 11-cm beaming curves measured in 1964. Jupiter's peak flux density decreased by 20% between 1964 and 1971, and 8% between 1969 and 1971.

Gulkis, S.↗

Fine structure of the sun at 1.3 cm wavelength

The two-element interferometer at Hat Creek Observatory was used at 1.3-cm wavelength to study the fine structure of the radio emissive regions on the sun. Observations of the quiet sun at 1.3 cm show sudden changes in the fringe amplitude and phase, lasting for typically about 5 to 8 min. Assuming that these events are identical in nature, a plot of peak amplitude vs the projected baseline at the time of the event suggests emission from a region of angular size of about 10 sec. The corresponding brightness temperature is 50,000 K. It is possible that these events may be related to the appearance and disappearance of groups of spicules or mottles.

Kundu, M. R.↗

Low voltage 30-cm ion thruster development

The basic goal was to advance the development status of the 30-cm electron bombardment ion thruster from a laboratory model to a flight-type engineering model (EM) thruster. This advancement included the more conventional aspects of mechanical design and testing for launch loads, weight reduction, fabrication process development, reliability and quality assurance, and interface definition, as well as a relatively significant improvement in thruster total efficiency. The achievement of this goal was demonstrated by the successful completion of a series of performance and structural integrity (vibration) tests. In the course of the program, essentially every part and feature of the original 30-cm Thruster was critically evaluated. These evaluations, led to new or improved designs for the ion optical system, discharge chamber, cathode isolator vaporizer assembly, main isolator vaporizer assembly, neutralizer assembly, packaging for thermal control, electrical terminations and structure.

King, H. J.↗

A 20000-hour endurance test of a structurally and thermally integrated 5-cm diameter ion thruster main cathode

A 5-cm diameter mercury ion thruster main cathode has completed over 20,000 hours of operation in an ongoing lifetime endurance test. The cathode operating parameters remained at acceptable performance levels throughout the test, the first 9175 hours of which were part of a thruster endurance test. After 20,000 hours, the cathode discharge was easily restarted, the tip orifice indicated negligible erosion and the tip heater showed no degradation. The cathode-isolator- vaporizer assembly, a major thruster subsystem, has thus successfully demonstrated an operational lifetime capability of 20,000 hours, which is the lifetime goal of the 8-cm diameter auxiliary propulsion ion thruster.

Wintucky, E. G.↗

Thermal analytic model of 30 cm engineering model mercury ion thruster

A lumped parameter thermal nodal network was developed for a 30 cm Engineering Model Mercury Ion Thruster. The network consists of approximately 100 nodes coded in SINDA format for use on the Univac 1106/1108 computer. This model takes into account internal dissipation, radiation, and conduction as well as environmental heating. A series of tests were performed to simulate a wide range of thermal environments on an operating 30 cm thruster, instrumented to measure the temperature distribution within the thruster. The results of these tests were used to calibrate the analytical model. The analytical model along with comparisons between analytical and experimental results for the various operating conditions are presented.

Oglebay, J. C.↗

The spectrum of Mars in the region 1800-3200 per cm

During the 1971 opposition of Mars, new infrared spectra covering the region 1800-3200 per cm were taken at a resolution of 0.095 per cm using a Connes'-type Fourier spectrometer on a 2.7 m telescope. No new trace constituents have, as yet, been found in the spectra, but several previously unobserved combination of isotopic bands of CO2 are visible. It has also been found possible to fit fairly well defined kinetic temperatures and Bond albedos to the data. The kinetic temperatures have been determined by a new technique. It is found that the albedo at 33 deg phase, which was determined a few days after the onset of the great dust storm of 1971, was significantly higher than for the clear atmosphere. The explanation for this phenomenon must await detailed radiative transfer calculations for a dust-laden atmosphere.

Beer, R.↗

A 20,000-hour endurance test of a structurally and thermally integrated 5-cm diameter ion thruster main cathode

A 5-cm diameter mercury ion thruster main cathode has completed over 20,000 hours of operation in an ongoing lifetime endurance test. The cathode operating parameters remained at acceptable performance levels throughout the test, the first 9175 hours of which were part of a thruster endurance test. After 20,000 hours, the cathode discharge was easily restarted, the tip orifice indicated negligible erosion and the tip heater showed no degradation. The cathode-isolator-vaporizer assembly, a major thruster subsystem, has thus successfully demonstrated an operational lifetime capability of 20,000 hours, which is the lifetime goal of the 8-cm diameter auxiliary propulsion ion thruster.

Wintucky, E. G.↗

Thermal analytical model of a 30 cm mercury ion thruster

A lumped parameter thermal nodal network has been developed for a 30 cm engineering model mercury ion thruster. The network consists of approximately 100 nodes coded in SINDA format for use on the Univac 1106/1108 computer. This model takes into account internal dissipation, radiation, and conduction as well as environmental heating. A series of tests were performed at NASA-Lewis Research Center to simulate a wide range of thermal environments on an operating 30 cm thruster, instrumented to measure the temperature distribution within the thruster. The results of these tests were used to calibrate the analytical model. Presented in this paper are a description of the analytical model along with comparisons between analytical and experimental results for the various operating conditions.

Oglebay, J. C.↗

A demonstration of a transportable radio interferometric surveying system with 3-cm accuracy on a 307-m base line

A precision geodetic measurement system (Aries, for Astronomical Radio Interferometric Earth Surveying) based on the technique of very long base line interferometry has been designed and implemented through the use of a 9-m transportable antenna and the NASA 64-m antenna of the Deep Space Communications Complex at Goldstone, California. A series of experiments designed to demonstrate the inherent accuracy of a transportable interferometer was performed on a 307-m base line during the period from December 1973 to June 1974. This short base line was chosen in order to obtain a comparison with a conventional survey with a few-centimeter accuracy and to minimize Aries errors due to transmission media effects, source locations, and earth orientation parameters. The base-line vector derived from a weighted average of the measurements, representing approximately 24 h of data, possessed a formal uncertainty of about 3 cm in all components. This average interferometry base-line vector was in good agreement with the conventional survey vector within the statistical range allowed by the combined uncertainties (3-4 cm) of the two techniques.

Ong, K. M.↗

Remote sensing of soil moisture by a 21-cm passive radiometer

Microwave sensors on Skylab collected data as part of the Earth Resources Experiment Package. An investigation was designed to obtain field observations of soil moisture content for comparison with data from Skylab. The 21-cm radiometer has been shown to be highly responsive to the moisture content of the upper 2.5-cm layer of soil. A composite relationship between the radiometric temperature and soil moisture content has been determined from five data sets obtained over Kansas and Texas. This relationship, having a correlation index of -0.96, has been used as a basis for calculating the soil moisture content of large areas across the United States.

Eagleman, J. R.↗

Experimental investigation of the excess charge and time constant of minority carriers in the thin diffused layer of 0.1 Ohm-cm silicon solar cells

The observed low open-circuit voltage in 0.1 Ohm-cm solar cells is probably related to an excessively high diode saturation current. Theoretical studies conducted by Lindholm et al. (1975) and by Godlewski et al. (1975) have shown that a high saturation current could be produced by either high recombination rates or bandgap narrowing effects. A description is given of an investigation which shows that bandgap narrowing effects have a first order significance in determining the charge carrier transport controlling the open-circuit voltage of 0.1 Ohm-cm silicon solar cells.

Godlewski, M. P.↗

Cycle life testing of 8-cm mercury ion thruster cathodes

Two main cathodes have successfully completed 2800 and 1980 cycles and three neutralizers, 3928, 3050, and 2850 cycles in ongoing cycle life tests of flight-type cathode-isolator-vaporizer and neutralizer-isolator-vaporizer assemblies for the 4.45 mN 8-cm Hg ion thruster system. Each cycle included one hour of cathode operation. Starting and operating conditions simulated those expected in a typical auxiliary propulsion mission duty cycle. The cycle life test results are presented along with results of an insert comparison test which led to the selection of a rolled foil insert type for the 8-cm Engineering Model Thruster cathodes.

Wintucky, E. G.↗

Fifteen cm mercury ion thruster research, 1976

Improvements in 15 cm diameter, SERT II, mercury ion thruster performance effected by the use of SHAG optics at 33 V discharge voltage were discussed. At a 200 eV/ion discharge power, 90 percent propellant utilization and 660 mA beam current condition a doubly-to-singly charged ion current ratio of about 4 percent was measured. Performance of the 15 cm multipole mercury thruster (optimized for length and the point of electron injection) was compared to that of divergent (SERT II) and cusped field designs and found to be comparable. The need for a magnetic baffle in the multipole thruster was identified and the preferred point of electron injection was at the upstream end of the discharge chamber. Results of preliminary tests on the effects of discharge voltage and total accelerating voltage on perveance and beam divergence characteristics of two grid ion optics were examined. Experimental data showing the effect of target temperature on sputtering rates in a mercury discharge environment were presented and a deficiency in the tests procedure was identified.

Wilbur, P. J.↗

Altimeter error sources at the 10-cm performance level

Error sources affecting the calibration and operational use of a 10 cm altimeter are examined to determine the magnitudes of current errors and the investigations necessary to reduce them to acceptable bounds. Errors considered include those affecting operational data pre-processing, and those affecting altitude bias determination, with error budgets developed for both. The most significant error sources affecting pre-processing are bias calibration, propagation corrections for the ionosphere, and measurement noise. No ionospheric models are currently validated at the required 10-25% accuracy level. The optimum smoothing to reduce the effects of measurement noise is investigated and found to be on the order of one second, based on the TASC model of geoid undulations. The 10 cm calibrations are found to be feasible only through the use of altimeter passes that are very high elevation for a tracking station which tracks very close to the time of altimeter track, such as a high elevation pass across the island of Bermuda. By far the largest error source, based on the current state-of-the-art, is the location of the island tracking station relative to mean sea level in the surrounding ocean areas.

Martin, C. F.↗

Cycle life testing of 8-cm mercury ion thruster cathodes

Two main cathodes have successfully completed 2800 and 1980 cycles and three neutralizers, 3928, 3050, and 2850 cycles in ongoing cycle life tests of flight-type cathode-isolator-vaporizer and neutralizer-isolator-vaporizer assemblies for the 4.45 mN 8-cm Hg ion thruster system. Each cycle included one hour of cathode operation. Starting and operating conditions simulated those expected in a typical auxiliary propulsion mission duty cycle. This paper presents the cycle life test results and also results of an insert comparison test which led to the selection of a rolled foil insert type for the 8-cm Engineering Model Thruster cathodes.

Wintucky, E. G.↗

Evolution and status of the 30-cm engineering model ion thruster

In the past five years the 30-cm ion thruster has developed from infancy to maturity through the joint efforts of the NASA Lewis Research Center (LeRC) and the Hughes Research Laboratories (HRL). The evolution of the 30-cm thruster from the 200-series design to the present 900-series is described. This evolution has included both breadboard and engineering model type thrusters. The evolution description includes functional requirements, design, performance, endurance test results, and major features. The major part of the discussion centers on Hughes-built hardware although NASA LeRC contributions are reflected in the designs.

Masek, T. D.↗