Search NASA⌕ Search

SEARCH · Search NASA

Results for “COOLING TESTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Gravitational Wave Detection on the Moon and the Moons of Mars

The Moon and the moons of Mars should be extremely quiet seismically and could therefore become sensitive gravitational wave detectors, if instrumented properly. Highly sensitive displacement sensors could be deployed on these planetary bodies to monitor the motion induced by gravitational waves. A superconducting displacement sensor with a 10-kg test mass cooled to 2 K will have an intrinsic instrument noise of 10(exp -16) m Hz(exp -1/2). These sensors could be tuned to the lowest two quadrupole modes of the body or operated as a wideband detector below its fundamental mode. An interesting frequency range is 0.1 to approx. 1 Hz, which will be missed by both the ground detectors on the Earth and LISA and would be the best window for searching for stochastic background gravitational waves. Phobos and Deimos have their lowest quadrupole modes at 0.2 to approx. 0.3 Hz and could offer a sensitivity h(sub min) = 10(exp -22) Hz(exp -1/2) within their resonance peaks, which is within two orders of magnitude from the goal of the Big Bang Observer (BBO). The lunar and Martian moon detectors would detect many interesting foreground sources in a new frequency window and could serve as a valuable precursor for BBO.

Paik, Ho Jung↗

Coupled Aerosol-Chemistry-Climate Twentieth-Century Transient Model Investigation: Trends in Short-Lived Species and Climate Responses

The authors simulate transient twentieth-century climate in the Goddard Institute for Space Studies (GISS) GCM, with aerosol and ozone chemistry fully coupled to one another and to climate including a full dynamic ocean. Aerosols include sulfate, black carbon (BC), organic carbon, nitrate, sea salt, and dust. Direct and BC snow-albedo radiative effects are included. Model BC and sulfur trends agree fairly well with records from Greenland and European ice cores and with sulfur deposition in North America; however, the model underestimates the sulfur decline at the end of the century in Greenland. Global BC effects peak early in the century (1940s); afterward the BC effects decrease at high latitudes of the Northern Hemisphere but continue to increase at lower latitudes. The largest increase in aerosol optical depth occurs in the middle of the century (1940s-80s) when sulfate forcing peaks and causes global dimming. After this, aerosols decrease in eastern North America and northern Eurasia leading to regional positive forcing changes and brightening. These surface forcing changes have the correct trend but are too weak. Over the century, the net aerosol direct effect is -0.41 Watts per square meter, the BC-albedo effect is -0.02 Watts per square meter, and the net ozone forcing is +0.24 Watts per square meter. The model polar stratospheric ozone depletion develops, beginning in the 1970s. Concurrently, the sea salt load and negative radiative flux increase over the oceans around Antarctica. Net warming over the century is modeled fairly well; however, the model fails to capture the dynamics of the observedmidcentury cooling followed by the late century warming.Over the century, 20% of Arctic warming and snow ice cover loss is attributed to the BC albedo effect. However, the decrease in this effect at the end of the century contributes to Arctic cooling. To test the climate responses to sulfate and BC pollution, two experiments were branched from 1970 that removed all pollution sulfate or BC. Averaged over 1970-2000, the respective radiative forcings relative to the full experiment were +0.3 and -0.3 Watts per square meter; the average surface air temperature changes were +0.2 degrees and -0.03 C. The small impact of BC reduction on surface temperature resulted from reduced stability and loss of low-level clouds.

Koch, Dorothy↗

Test Capabilities of the NASA Langley Direct Connect Supersonic Combustion Test Facility

In 1969 a combustion-heated direct-connect test facility was assembled at the NASA Langley Research Center and used to support NASA’s Hypersonic Research Engine program. Later, the facility was used to support NASA’s generic hypersonic program, assessing the mixing, ignition, flame holding, and combustion characteristics of ramjet and scramjet combustors. Over the years, the facility has been updated and modified to conduct increasingly complicated tests. Today, the facility is known as the Direct Connect Supersonic Combustion Test Facility (DCSCTF) and is part of the NASA Langley Scramjet Test Complex. Recently, the facility has been used by external customers to test fuel-cooled and uncooled, flight-like test articles. Tests have been conducted at nominal Mach 5 flight conditions for up to 15 minutes of continuous operation. The facility remains a viable and useful tool in the support of various Department of Defense projects.

Diego P Capriotti↗

Test Capabilities of the NASA Langley Direct Connect Supersonic Combustion Test Facility with Historical Perspective

In 1969, a combustion-heated direct-connect test facility was assembled at the NASA Langley Research Center to conduct basic research in ramjet and scramjet propulsion systems. The facility was initially used in assessing the mixing, ignition, flame holding, and combustion characteristics of various ramjet and scramjet combustors. Over the years, the facility was updated and modified to conduct increasingly longer and more complicated tests. Today, the facility is known as the Direct Connect Supersonic Combustion Test Facility and is part of the NASA Langley Scramjet Test Complex. More recently, the facility has been used by external customers to test fuel-cooled and uncooled, flight-like test articles. Tests have been conducted at ramjet flight conditions for up to 15 minutes of continuous operation. Even though the facility is nearly 50 years old, it remains a viable and useful tool in the support of various U.S. hypersonic programs.

direct connect test facility↗

Superconducting Notch Filter for RFI Mitigation in Ground-Based Radio Telescope

This paper presents a high-rejection, thin-film HTS, microstrip bandstop filter to prevent a local and high-power RFI source from interfering with NASA GGAO’s VGOS cryogenic receiver. This filter has an excellent 2.7%, 50-dB-fractionalbandwidth and a center stop-band frequency of 9.41 GHz. It does not contain any narrow or interdigital features as found in some designs, which reduces the fringing electric fields and improves its power handling capability. The YBCO films were grown on 435-µm-thick R-plane sapphire substrate and the anisotropic behavior was modeled and simulated with a high degree of accuracy. The device was tested while cooled to 77 K and the measurements agree well with simulation.

high-temperature superconductors↗

Cryogenic Vacuum Chamber Testing of A Conductively-Cooled, High Temperature Superconducting Rotor for a 1.4 MW Electric Machine for Aeronautics Applications

This paper presents the second ever demonstration of a superconducting rotor cooled only via conductive connection to a cryocooler, i.e., without pumped or solid cryogens. The fullscale rotor was operated statically in its intended environment – about 1e-3 torr vacuum with only conductive cooling through mechanical connections to a cryocooler contained on the rotor. Stable operation of the rotor in a representative magnetic environment was demonstrated up to its rated direct current (57.2 A) and the designed temperature limit for the superconductor (62 K). Additional electrical measurements increased confidence that the superconducting coils functioned as intended. A collection of steady state temperature distributions was measured at operating and non-operating conditions. In all but one case, the observed temperature gradient between the cold tip and superconducting coils satisfies the design but with little margin. Opportunities to reduce the gradient are identified.

Electrified aircraft propulsion↗

Cryogenic Vacuum Chamber Testing of A Conductively-Cooled, High Temperature Superconducting Rotor for a 1.4 MW Electric Machine for Aeronautics Applications

This paper presents the first ever demonstration of a superconducting rotor cooled conductively without a cryogenic fluid or solid. The full-scale rotor was operated statically in its intended environment – about 1e-3 torr vacuum with only conductive cooling through mechanical connections to a cryocooler contained on the rotor. Stable operation of the rotor in a representative magnetic environment was demonstrated up to its rated direct current (57.2 A) and the designed temperature limit for the superconductor (62 K). Additional electrical measurements increased confidence that the superconducting coils functioned as intended. A collection of steady state temperature distributions was measured at operating and non-operating conditions. In all but one case, the observed temperature gradient between the cold tip and superconducting coils satisfies the design but with little margin. Opportunities to reduce the gradient are identified.

Electrified aircraft propulsion↗

NASA’s Quiet Electric ENgines (QUEEN): Summary of the QUEEN V2 Test

A liquid-cooled electric ducted fan system was designed, built, and tested at the NASA Glenn Research Center. Main components of the system include a Commercial-Off- the-Shelf (COTS) fan and motor, and a custom-designed heat exchanger integrated into the fan duct. Fan speed, thrust, and cooling system thermal performance was measured in this static ground test of the propulsor. This propulsor prototype is one of NASA’s Quiet Electric ENgines (QUEENs) and is designated the ‘QUEEN V2.’ The Quiet Electric Engines are being developed for the 25% scale model of the Subsonic Aft Engine (SUSAN) Flight Research Vehicle and are intended to explore the potential of distributed electric propulsion for regional single-aisle aircraft. This test demonstrated the functionality of the QUEEN V2, quantified the thrust produced by the electrofan, and characterized the electrical and thermal performance of the system. Lessons learned will be used to guide development of future QUEEN prototypes.

Aerodynamics↗

NASA’s Quiet Electric ENgines (QUEEN): Summary of the QUEEN V2 Test

A liquid-cooled electric ducted fan system was designed, built, and tested at the NASA Glenn Research Center. Main components of the system include a Commercial-Off- the-Shelf (COTS) fan and motor, and a custom-designed heat exchanger integrated into the fan duct. Fan speed, thrust, and cooling system thermal performance was measured in this static ground test of the propulsor. This propulsor prototype is one of NASA’s Quiet Electric ENgines (QUEENs) and is designated the ‘QUEEN V2.’ The Quiet Electric Engines are being developed for the 25% scale model of the Subsonic Aft Engine (SUSAN) Flight Research Vehicle and are intended to explore the potential of distributed electric propulsion for regional single-aisle aircraft. This test demonstrated the functionality of the QUEEN V2, quantified the thrust produced by the electrofan, and characterized the electrical and thermal performance of the system. Lessons learned will be used to guide development of future QUEEN prototypes.

Aeronautics-General↗

Ground Tests of a Radial Air-Cooled Engine to Correct a Poor Circumferential Pressure-Recovery Distribution

This report presents the results of the tests of a power-plant installation to improve the circumferential pressure-recovery distribution at the face of the engine. An underslung "C" cowling was tested with two propellers with full cuffs and with a modification to one set of cuffs. Little improvement was obtained because the base sections of the cuffs were stalled. A set of guide vanes boosted the over-all pressures and helped the pressure recoveries for a few of the cylinders. Making the underslung cowling into a symmetrical "C" cowling evened the pressure distribution; however, no increases in front pressures were obtained. The pressures at the top cylinders remained low and the high pressures at the bottom cylinders were reduced. At higher powers and engine speeds, the symmetrical cowling appeared best from the standpoint of over-all cooling characteristics.

Gallagher, James J.↗

Thermally Simulated Testing of a Direct-Drive Gas-Cooled Nuclear Reactor

This paper describes the concept and preliminary component testing of a gas-cooled, UN-fueled, pin-type reactor which uses He/Xe gas that goes directly into a recuperated Brayton system to produce electricity for nuclear electric propulsion. This Direct-Drive Gas-Cooled Reactor (DDG) is designed to be subcritical under water or wet-sand immersion in case of a launch accident. Because the gas-cooled reactor can directly drive the Brayton turbomachinery, it is possible to configure the system such that there are no external surfaces or pressure boundaries that are refractory metal, even though the gas delivered to the turbine is 1144 K. The He/Xe gas mixture is a good heat transport medium when flowing, and a good insulator when stagnant. Judicious use of stagnant cavities as insulating regions allows transport of the 1144-K gas while keeping all external surfaces below 900 K. At this temperature super-alloys (Hastelloy or Inconel) can be used instead of refractory metals. Super-alloys reduce the technology risk because they are easier to fabricate than refractory metals, we have a much more extensive knowledge base on their characteristics, and, because they have a greater resistance to oxidation, system testing is eased. The system is also relatively simple in its design: no additional coolant pumps, heat exchanger, or freeze-thaw systems are required. Key to success of this concept is a good knowledge of the heat transfer between the fuel pins and the gas, as well as the pressure drop through the system. This paper describes preliminary testing to obtain this key information, as well as experience in demonstrating electrical thermal simulation of reactor components and concepts.

Godfroy, Thomas↗

Flight test method for the determination of reciprocating engine cooling requirements

It is pointed out that the effective cooling of aircraft reciprocating engines is still a problem area for the general aviation industry. Miley et al. (1981) have reported the results of an investigation of problems associated with cooling and installation aerodynamics. A description is given of a flight test procedure which was developed in connection with the considered investigation. It is shown that the test procedure provides valid cooling requirements data for a particular installation. The data are in terms of easily measurable parameters. The employment of the test procedure, which is based on the NACA cooling correlation method, can lead to more effective cooling installations and the solution of existing cooling problems.

Miley, S. J.↗

The cryogenic wind tunnel concept for high Reynolds number testing

Theoretical considerations indicate that cooling the wind-tunnel test gas to cryogenic temperatures will provide a large increase in Reynolds number with no increase in dynamic pressure while reducing the tunnel drive-power requirements. Studies were made to determine the expected variations of Reynolds number and other parameters over wide ranges of Mach number, pressure, and temperature, with due regard to avoiding liquefaction. Practical operational procedures were developed in a low-speed cryogenic tunnel. Aerodynamic experiments in the facility demonstrated the theoretically predicted variations in Reynolds number and drive power. The continuous-flow-fan-driven tunnel is shown to be particularly well suited to take full advantage of operating at cryogenic temperatures.

Kilgore, R. A.↗

Experimental investigation of aerodynamic performance of cooled turbine vanes at gas- to collant-temperature ratios up to 2.75

The results of an experimental investigation of the aerodynamic performance of two geometrically similar turbine vanes with different cooling designs are presented. The test vanes were a convection-film-cooled vanes and a transpiration-cooled vane. A solid uncooled vane with the same aerodynamic profile as the cooled vane was also tested. Four vanes of each type were tested in an annular sector cascade. The cooled vanes were tested at primary to coolant temperature ratios of 1.0, 1.75, and 2.75 and a coolant to primary pressure ratios of 1.0, 1.2, and 1.5. This resulted in coolant flows up to about 10 percent of the primary flow. The principal measurements were surveys of vane exit total pressure, total temperature, and static pressure. The report includes a brief description of the test facility and the design of the test vanes. The test results presented include weight flow and efficiency data for the uncooled vanes and coolant flow, primary flow, and efficiency data as functions of the cooling variables for the cooled vanes.

Stabe, R. G.↗