At least 217 records · Page 12

PWM Switching Frequency Effects on Eddy Current Sensors for Magnetically Suspended Flywheel Systems

A flywheel magnetic bearing (MB) pulse width modulated power amplifier (PWM) configuration is selected to minimize noise generated by the PWMs in the flywheel position sensor system. Two types of noise are addressed: beat frequency noise caused by variations in PWM switching frequencies, and demodulation noise caused by demodulation of high order harmonics of the switching voltage into the MB control band. Beat frequency noise is eliminated by synchronizing the PWM switch frequencies, and demodulation noise is minimized by selection of a switching frequency which does not have harmonics at the carrier frequency of the sensor. The recommended MB PWM system has five synchronized PWMs switching at a non-integer harmonic of the sensor carrier.

Jansen, Ralph↗

Evaluation of Silicon-on-Insulator HTOP-01 Operational Amplifier for Wide Temperature Operation

Electronics capable of operation under extreme temperatures are required in many of NASA space exploration missions. Aerospace and military applications, as well as some terrestrial industries constitute environments where electronic systems are anticipated to be exposed to extreme temperatures and wide-range thermal swings. Electronics that are able to withstand and operate efficiently in such harsh environments would simplify, if not eliminate, traditional thermal control elements and their associated structures for proper ambient operation. As a result, overall system mass would be reduced, design would be simplified, and reliability would be improved. Electronic parts that are built utilizing silicon-on-insulator (SOI) technology are known to offer better radiation-tolerance compared to their conventional silicon counterparts, provide faster switching, and consume less power. They also exhibit reduced leakage current and, thus, they are often tailored for high temperature operation. These attributes make SOI-based devices suitable for use in harsh environments where extreme temperatures and wide thermal swings are anticipated. A new operational amplifier, based on silicon-on-insulator technology and geared for high temperature well-logging applications, was recently introduced by Honeywell Corporation. This HTOP-01 dual precision operational amplifier is a low power device, operates on a single supply, and has an internal oscillator and an external clocking option [1]. It is rated for operation from -55 C to +225 C with a maximum output current capability of 50 mA. The amplifier chip is designed as a 14-pin, hermetically-sealed device in a ceramic package. Table I shows some of the device manufacturer s specifications.

Patterson, Richard↗

Experimental investigation of possible geomagnetic feedback from energetic (0.1 to 16 keV) terrestrial O(+) ions in the magnetotail current sheet

Data from energetic ion mass spectrometers on the ISEE 1 and AMPTE/CCE spacecraft are combined with geomagnetic and solar indices to investigate, in a statistical fashion, whether energized O(+) ions of terrestrial origin constitute a source of feedback which triggers or amplifies geomagnetic activity as has been suggested in the literature, by contributing a destabilizing mass increase in the magnetotail current sheet. The ISEE 1 data (0.1-16 keV/e) provide in situ observations of the O(+) concentration in the central plasma sheet, inside of 23 R(sub E), during the rising and maximum phases of solar cycle 21, as well as inner magnetosphere data from same period. The CCE data (0.1-17 keV/e) taken during the subsequent solar minimum all within 9 R(sub E). provide a reference for long-term variations in the magnetosphere O(+) content. Statistical correlations between the ion data and the indices, and between different indices. all point in the same direction: there is probably no feedback specific to the O(+) ions, in spite of the fact that they often contribute most of the ion mass density in the tail current sheet.

Lennartsson, O. W.↗

Dynamic magneto-chiral instability in photoexcited tellurium

In systems of charged chiral fermions out of equilibrium, an electric current parallel to a magnetic field can generate a dynamic instability that amplifies electromagnetic waves. Whether this mechanism also operates in chiral solid-state systems has remained uncertain. Here we observe signatures of a dynamic magneto-chiral instability in elemental tellurium, a structurally chiral crystal, using time-domain terahertz emission spectroscopy. Under transient photoexcitation in a moderate magnetic field, we observe terahertz radiation with coherent modes that grow in amplitude over time. We present a theoretical model that describes this behaviour based on a dynamic instability of electromagnetic waves interacting with infrared-active oscillators of acceptor states in tellurium, giving rise to an amplifying polariton. These results demonstrate that magneto-chiral instabilities can emerge in solid-state systems and establish a mechanism for terahertz-wave amplification in chiral materials.

42 ENGINEERING↗

Solar cell angular position transducer

An angular position transducer utilizing photocells and a light source is disclosed. The device uses a fully rotatable baffle which is connected via an actuator shaft to the body whose rotational displacement is to be measured. The baffle blocks the light path between the light source and the photocells so that a constant semicircular beam of light reaches the photocells. The current produced by the photocells is fed through a resistor, a differential amplifier measures the voltage drop across the resistor which indicates the angular position of the actuator shaft and hence of the object.

Sandford, M. C.↗

Variable Synthetic Capacitance

Feedback amplifier circuit synthesizes electronically variable capacitance. Variable Synthetic Capacitor is amplifier circuit with follower/feedback configuration. Effective input capacitance depends on input set current. If synthetic capacitor is connected across resonant element of oscillator, oscillator frequency controlled via input set current. Circuit especially suitable for fine frequency adjustments of piezoelectric-crystal or inductor/capacitor resonant oscillators.

Kleinberg, L. L.↗

SiC-based Photo-detectors for UV, VUV, EUV and Soft X-ray Detection

A viewgraph presentation describing an ideal Silicon Carbide detector for ultraviolet, vacuum ultraviolet, extreme ultraviolet and soft x-ray detection is shown. The topics include: 1) An ideal photo-detector; 2) Dark current density of SiC photodiodes at room temperature; 3) Dark current in SiC detectors; 4) Resistive and capacitive feedback trans-impedance amplifier; 5) Avalanche gain; 6) Excess noise; 7) SNR in single photon counting mode; 8) Structure of SiC single photon counting APD and testing structure; 9) Single photon counting waveform and testing circuit; 10) Amplitude of SiC single photon counter; 11) Dark count of SiC APD photon counters; 12) Temperature-dependence of dark count rate; 13) Reduce the dark count rate by reducing the breakdown electric field; 14) Spectrum range for SiC detectors; 15) QE curves of Pt/4H-SiC photodiodes; 16) QE curve of SiC; 17) QE curves of SiC photodiode vs. penetration depth; 18) Visible rejection of SiC photodiodes; 19) Advantages of SiC photodiodes; 20) Competitors of SiC detectors; 21) Extraterrestrial solar spectra; 22) Visible-blind EUV detection; 23) Terrestrial solar spectra; and 24) Less than 1KeV soft x-ray detection.

Yan, Feng↗

Power density measurements in the near field of the DSS 13 26-meter antenna

Power density measurements were made at Deep Space Station (DSS) 13 in the near field of the 26-m antenna to determine if radio frequency (rf) fields generated by the 20-kW transmitters could be responsible for the failure of three solid state rf amplifiers. These amplifiers are used in the Search for Extraterrestrial Intelligence (SETI) Radio Spectrum Surveillance System, which is currently located at the site. Measurements were made independently for one transmitter at 7150 MHz, and both transmitters together. Measurement results are tabulated and compared with predicted power densities under the measurement conditions. The results agree with the predictions within a factor of two. The predictions appear to give worst case values. Measurements indicated that amplifier failures are not attributable to the transmitter.

Jackson, E. B.↗

Transverse BBU Suppression with Feedback for Energy Recovery Linacs

In this study, we present beam dynamics simulations of the Strong Hadron Cooling (SHC) Energy Recovery Linac (ERL) that incorporate a feedback (FB) system designed to mitigate Beam Breakup (BBU) instabilities. The FB effectively suppresses BBU and increases the threshold current by roughly an order of magnitude. Our analysis revealed the aliasing behavior of the dominant higher-order mode (HOM) and its suppression by the FB, as evident from the power spectral density (PSD) of the beam centroid’s horizontal motion at the exit of the final linac section. Although the FB system— even when affected by noise—successfully reduced the BBU peak, it also amplified the PSD at other frequencies. These results provide important insights into BBU suppression and threshold current enhancement in ERLs.

Setiniyaz, S. [Thomas Jefferson National Accelerat↗

Fail-Safe Operation of a High-Temperature Magnetic Bearing Investigated for Gas Turbine Engine Applications

The Structural Mechanics and Dynamics Branch at the NASA Glenn Research Center has developed a three-axis high-temperature magnetic bearing suspension rig to enhance the safety of the bearing system up to 1000 F. This test rig can accommodate thrust and radial bearings up to a 22.84 cm (9 in.) diameter with a maximum axial loading of 22.25 kN (5000 lb) and a maximum radial loading up to 4.45 kN (1000 lb). The test facility was set up to test magnetic bearings under high-temperature (1100 F) and high-speed (20,000 rpm) conditions. The magnetic bearing is located at the center of gravity of the rotor between two high-temperature grease-packed mechanical ball bearings. The drive-end duplex angular contact ball bearing, which is in full contact, acts as a moment release and provides axial stability. The outboard end ball bearing has a 0.015-in. radial clearance between the rotor to act as a backup bearing and to compensate for axial thermal expansion. There is a 0.020-in. radial air gap between the stator pole and the rotor. The stator was wrapped with three 1-kW band heaters to create a localized hot section; the mechanical ball bearings were outside this section. Eight threaded rods supported the stator. These incorporated a plunger and Bellville washers to compensate for radial thermal expansion and provide rotor-to-stator alignment. The stator was instrumented with thermocouples and a current sensor for each coil. Eight air-cooled position sensors were mounted outside the hot section to monitor the rotor. Another sensor monitored this rotation of the outboard backup bearing. Ground fault circuit interrupts were incorporated into all power amplifier loops for personnel safety. All instrumentation was monitored and recorded on a LabView-based data acquisition system. Currently, this 12-pole heteropolar magnetic bearing has 13 thermal cycles and over 26 hr of operation at 1000 F.

Choi, Benjamin B.↗

Transistor biased amplifier minimizes diode discriminator threshold attenuation

Transistor biased amplifier has a biased diode discriminator driven by a high impedance /several megohms/ current source, rather than a voltage source with several hundred ohms output impedance. This high impedance input arrangement makes the incremental impedance of the threshold diode negligible relative to the input impedance.

Larsen, R. N.↗

Method for reducing snap in magnetic amplifiers

Method of reducing snap in magnetic amplifiers uses a degenerative feedback circuit consisting of a resistor and a separate winding on a magnetic core. The feedback circuit extends amplifier range by allowing it to be used at lower values of output current.

Fischer, R. L. E.↗

The revolution in data gathering systems

This paper gives a review of the data-acquisition systems used in NASA's wind tunnels from the 1950's to the present as a basis for assessing the impact of minicomputers and microcomputers on data acquisition and processing. The operation and disadvantages of wind-tunnel data systems are summarized for the period before 1950, the early 1950's, the early and late 1960's, and the early 1970's. Some significant advances discussed include the use or development of solid-state components, minicomputer systems, large central computers, on-line data processing, autoranging DC amplifiers, MOS-FET multiplexers, MSI and LSI logic, computer-controlled programmable amplifiers, solid-state remote multiplexing, integrated circuits, and microprocessors. The distributed system currently in use with the 40-ft by 80-ft wind tunnel at Ames Research Center is described in detail. The expected employment of distributed systems and microprocessors in the next decade is noted.

Cambra, J. M.↗

Rise-time control in saturated amplifiers

Inductor in transistor emitter circuit controls output rise time of saturated amplifier thereby reducing radiated noise and distortion in subsequent circuits. Device also improves current balancing in push/pull transformer circuits. Resulting circuits are self compensating for temperature.

Theall, C. E.↗

Electro-optic network analyzer

The bandwidth of frequency domain measurement methods of electrical signals has usually been far greater than the bandwidth of time domain methods. The primary limits of the time domain approach have been the 20 to 30 GHz bandwidth limit for electronic waveform acquisition instrumentation, and the lack of usable electrical pulse generators for excitation of a test device. The bandwidth of frequency domain network analysis appears to have reached a plateau of between 100 to 200 GHz, while time domain measurement have improved markedly in both bandwidth and sensitivity with the introduction of the pulsed laser based electro-optic sampling approach. Network analysis or the measurement of device scattering parameters provides information necessary to the design of electronic network such as high frequency amplifiers, mixers, and phase shifter. The bandwidth of frequency domain network analysis is currently being exceeded by the next generations of high frequency transistors and devices. Thus the electro-optic approach is a natural means of extending network analysis into the range above 100 GHz by employing time domain methods. In this approach, a suitable electrical excitation pulse is generated and propagated along a transmission line toward a test device. In the picosecond domain, laser driven photoconductive switches provide a unique method of generating electrical transients. Several materials were studied for generating short electrical pulses using photoconductive switches. The various semiconductive materials tested for photoconductive switching, and the electro-optic measurement technique used to characterize the material performance are described.

Jackson, Todd A.↗

X-ray refelection from photoionized media in active galactic nuclei

We calculate the spectrum of X-ray radiation and reprocessed by a partly ionized optically thick medium in an active galactic nucleus. We self-consistently calculate the ionization balance and thermal balance in the medium along with the distribution of X-ray intensity with optical depth. In addition to absorption or scattering of the incident X-rays, we also compute the spectrum of X-rays emitted by the material, including lines, edges, and bremsstrahlung. The albedo of the medium depends primarily on the X-ray ionization parameter (ratio of incident flux to gas density, zeta(sub Chi), and secondarily on the UV flux generated by dissipation inside the disk; we locate the critical range of zeta(sub Chi) over which the albedo increases from small to nearly unity. While the continuum reflection is very weak below 10 keV when zeta(sub Chi) is small, significnat fluxes are emitted in atomic lines and edges in this energy range. In the limit of large zeta(sub Chi), the albedo below 10 keV increases, but reflection in this band is never gray: some photoelectric absorption remains up to rather large values of zeta(sub Chi), while at still higher values, inverse Compton scattering amplifies the soft X-ray flux. These features are sufficiently sharp that current and near-future X-ray experiments should permit diagnostic measures of zeta(sub Chi).

Zycki, Piotr T.↗