Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Innovative methodology for intercomparison of radionuclide calibrators using short half-life in situ prepared radioactive sources

Purpose: An original radionuclide calibrator method for activity determination is presented. The method could be used for intercomparison surveys for short half-life radioactive sources used in Nuclear Medicine, such as{sup 99m}Tc or most positron emission tomography radiopharmaceuticals. Methods: By evaluation of the resulting net optical density (netOD) using a standardized scanning method of irradiated Gafchromic XRQA2 film, a comparison of the netOD measurement with a previously determined calibration curve can be made and the difference between the tested radionuclide calibrator and a radionuclide calibrator used as reference device can be calculated. To estimate the total expected measurement uncertainties, a careful analysis of the methodology, for the case of{sup 99m}Tc, was performed: reproducibility determination, scanning conditions, and possible fadeout effects. Since every factor of the activity measurement procedure can influence the final result, the method also evaluates correct syringe positioning inside the radionuclide calibrator. Results: As an alternative to using a calibrated source sent to the surveyed site, which requires a relatively long half-life of the nuclide, or sending a portable calibrated radionuclide calibrator, the proposed method uses a source preparedin situ. An indirect activity determination is achieved by the irradiation of a radiochromic film using {sup 99m}Tc under strictly controlled conditions, and cumulated activity calculation from the initial activity and total irradiation time. The irradiated Gafchromic film and the irradiator, without the source, can then be sent to a National Metrology Institute for evaluation of the results. Conclusions: The methodology described in this paper showed to have a good potential for accurate (3%) radionuclide calibrators intercomparison studies for{sup 99m}Tc between Nuclear Medicine centers without source transfer and can easily be adapted to other short half-life radionuclides.

07 ISOTOPE AND RADIATION SOURCES↗

HIGH-PRECISION ASTROMETRIC MILLIMETER VERY LONG BASELINE INTERFEROMETRY USING A NEW METHOD FOR ATMOSPHERIC CALIBRATION

We describe a new method which achieves high-precision very long baseline interferometry (VLBI) astrometry in observations at millimeter (mm) wavelengths. It combines fast frequency-switching observations, to correct for the dominant non-dispersive tropospheric fluctuations, with slow source-switching observations, for the remaining ionospheric dispersive terms. We call this method source-frequency phase referencing. Provided that the switching cycles match the properties of the propagation media, one can recover the source astrometry. We present an analytic description of the two-step calibration strategy, along with an error analysis to characterize its performance. Also, we provide observational demonstrations of a successful application with observations using the Very Long Baseline Array at 86 GHz of the pairs of sources 3C274 and 3C273 and 1308+326 and 1308+328 under various conditions. We conclude that this method is widely applicable to mm-VLBI observations of many target sources, and unique in providing bona fide astrometrically registered images and high-precision relative astrometric measurements in mm-VLBI using existing and newly built instruments, including space VLBI.

79 ASTRONOMY AND ASTROPHYSICS↗

Efficient calibration for imperfect computer models

Many computer models contain unknown parameters which need to be estimated using physical observations. Furthermore, the calibration method based on Gaussian process models may lead to unreasonable estimate for imperfect computer models. In this work, we extend their study to calibration problems with stochastic physical data. We propose a novel method, called the L 2 calibration, and show its semiparametric efficiency. The conventional method of the ordinary least squares is also studied. Theoretical analysis shows that it is consistent but not efficient. Here, numerical examples show that the proposed method outperforms the existing ones.

97 MATHEMATICS AND COMPUTING↗

A comparative analysis of YOLOv8 and U-Net image segmentation approaches for transmission electron micrographs of polycrystalline thin films

Metallic thin films offer a platform to experimentally study the dynamics of microstructural evolution, but the required transmission electron microscopy (TEM)-based imaging generates complex images that are challenging to segment and quantify. This work provides a comparative analysis of a new YOLOv8 model and an established U-Net model for bright-field TEM images of polycrystals, employing a framework leveraging physical observables to evaluate performance against two hand-traced benchmark datasets. This methodology obviates the comparison of large, diversely structured, and manually labeled datasets that are required to assess performance on a per-image/per-pixel basis. It is found that the YOLOv8 model, adapted for real-time instance segmentation, has up to 43× faster inferencing (NVIDIA GeForce RTX 4090) compared to U-Net and reconstructs hand-traced grain size distributions (GSDs) with excellent fidelity, finding mean diameter within 3% for grains near an optimal magnification; for grains that deviate from the optimal pixel-diameter, the size of small- (large)-diameter grains is systematically over- (under)-estimated. This is partially mitigated by including scale-aware augmentations during training. Moreover, when the bias is corrected post-inference by a rigid shift in distribution, the YOLOv8 model reproduces ground truth GSDs with exceptional fidelity, with statistical tests indicating <5% probability that the distributions are distinct. Based on ground truth data, calibration curves pertaining to this shift can be constructed for a given model. This issue is not present in the U-Net model’s results, indicating that for quantitative measurements where the true size of objects is of interest, special procedures must be implemented for YOLO-based models.

36 MATERIALS SCIENCE↗

The Closed Orbit Measurement System at the DELTA Synchrotron Radiation Facility And First Investigations Concerning the Installation of a Beam Based BPM Calibration System

For a synchrotron radiation source it is necessary to operate a monitoring system to determine the beam position with high resolution and accuracy with respect to the axis of the quadrupole magnets. In this paper the present closed orbit measurement system of the DELTA SR-Facility, concerning the hardware setup, data processing and the calibration methods, will be presented. The results of the calibration measurements and the recent operating experience will be discussed. These results show, that the system is close to the design resolution. But the BPM offsets with respect to the magnetic center of the quadrupole magnets turn out to be not acceptable. For some BPMs they are in the order of several 100 micro m. Therefore it was decided to install a beam based BPM calibration system in the near future . This system should allow to determine the BPM offsets relative to the center of the quadrupole magnets for all 40 BPMs. It is planned to install a system in order to change the focussing strength of each quadrupole individually either in a static or dynamic way.

43 PARTICLE ACCELERATORS↗

To Sample or Not to Sample - An Investigation Into the Uncertainty from Sampling Followed by Laboratory Analysis Versus In-Toto Gamma Spectroscopy for Situations of Non-Uniform Radioactivity Distribution

During the decommissioning of structures and the remediation of soil, material that is known or suspected to be contaminated with radioactivity must be assayed. For many, if not most, of the cases, the radioactive material concentration can be determined or inferred by gamma spectroscopy. In most, if not all, of these cases, the radioactivity is not uniformly distributed. For these situations, is it better to perform in-toto measurements of the entire item, or is it better to extract a sample and analyze that sample? For the in-toto gamma spectroscopy measurement, the results will not be accurate unless the calibration method perfectly represents the measured item. And since the calibrations normally assume uniformly distributed radioactivity, any nonuniform distribution of radioactivity in the measured material will cause an error in the results. A mathematical program using probabilistic methods has been developed to estimate the uncertainty in in-toto gamma spectroscopy measurements. This program has the capability of determining the efficiency of various types of non-uniform radioactivity distributions and to compare it to the uniform distribution efficiency. Repeating this for a large number of random tries allows the estimation of the measurement uncertainty. A new feature has been added to the program to simulate the extraction of a sample from these same non-uniform distributions, to compute the average concentration in this extracted sample, and to compare it to the average concentration in the original item to be measured. Repeating this for a large number of random tries allows the estimation of the sampling uncertainty. These two computations were run on several different 'typical' contamination measurement scenarios [200 liter drums, 27 cubic meter 'truck' containers, 0.01-10 liter 'laboratory' containers, and 3600 square meter soil 'in-situ' plots]. In all cases examined, the sampling uncertainty was larger than the in-toto gamma measurement uncertainty - typically about an order of magnitude larger. This means that in-toto measurements are likely better for situations where the activity is not homogeneous, and where gamma spectroscopy is appropriate. If sampling is to be done, then the best results will be when the largest mass of sample is extracted and when it is made up from the largest number of discrete sub-samples. The more extreme the non-uniformity, the more important this is. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An energy fluence-convolution model for amorphous silicon EPID dose prediction

In this work, an amorphous silicon electronic portal imaging device (a-Si EPID) dose prediction model based on the energy fluence model of the Pinnacle treatment planning system Version 7 (Philips Medical Systems, Madison, WI) is developed. An energy fluence matrix at very high resolution (<1 mm) is used to incorporate multileaf collimator (MLC) leaf effects in the predicted EPID images. The primary dose deposited in the EPID is calculated from the energy fluence using experimentally derived radially dependent EPID interaction coefficients. Separate coefficients are used for the open beam energy fluence component and the component of the energy fluence transmitted through closed MLC leaves to each EPID pixel. A spatially invariant EPID dose deposition kernel that describes both radiative dose deposition, central axis EPID backscatter, and optical glare is convolved with the primary dose. The kernel is further optimized to give accurate EPID penumbra prediction and EPID scatter factor with changing MLC field size. An EPID calibration method was developed to reduce the effect of nonuniform backscatter from the support arm (E-arm) in a calibrated EPID image. This method removes the backscatter component from the pixel sensitivity (flood field) correction matrix retaining only field-specific backscatter in the images. The model was compared to EPID images for jaw and MLC defined open fields and eight head and neck intensity modulated radiotherapy (IMRT) fields. For the head and neck IMRT fields with 2%, 2 mm criteria 97.6{+-}0.6% (mean {+-}1 standard deviation) of points passed with a gamma index less than 1, and for 3%, 3 mm 99.4{+-}0.4% of points were within the criteria. For these fields, the 2%, 2 mm pass score reduced to 96.0{+-}1.5% when backscatter was present in the pixel sensitivity correction matrix. The model incorporates the effect of MLC leaf transmission, EPID response to open and MLC leakage dose components, and accurately predicts EPID images of IMRT fields. Removing the backscatter component of the pixel sensitivity matrix correction reduces the effect of nonuniform E-arm backscatter.

61 RADIATION PROTECTION AND DOSIMETRY↗

Laser-induced breakdown spectroscopy for determination of the organic oxygen content in anthracite coal under atmospheric conditions

Laser-induced breakdown spectroscopy has been used to measure the organic oxygen content in pulverized anthracite coal under atmospheric conditions. Special spectral processing including the optimal O(I) emission-line selection by comparing the spectral correlation coefficients with the N(I) line, internal normalization with the N(I) line, and temperature correction are proposed and employed to satisfy the multi-line analysis method and yield the most accurate quantitative results. The calibration method for determining the organic oxygen content of coal is presented, with an accuracy of 1.15-1.37% and an average relative error of 19.39% being evaluated through an experiment performed on six anthracite coal samples. The relative measurement error distribution has also been studied.

01 COAL, LIGNITE, AND PEAT↗

Calibration of the Gamma Knife Perfexion using TG-21 and the solid water Leksell dosimetry phantom

Purpose: To calibrate a Gamma Knife (GK) Perfexion using TG-21 with updated chamber-dependent values for modern microionization chambers in the new solid water Leksell dosimetry phantom. This work illustrates a calibration method using commercially available equipment, instruments, and an established dosimetry protocol that may be adopted at any GK center, thus reducing the interinstitutional variation in GK calibration. The calibration was verified by three third-party dosimetry checks. In addition, measurements of the relative output factors are presented and compared to available data and the new manufacturer-provided relative output factors yet to be released. Methods: An absolute dose calibration based on the TG-21 formalism, utilizing recently reported phantom material and chamber-dependent factors, was performed using a microionization chamber in a spherical solid water phantom. The result was compared to other calibration protocols based on TG-51. Independent verification of the machine output was conducted through M.D. Anderson Dosimetry Services (MDADS), using thermoluminescent dosimeters (TLDs) in an anthropomorphic head phantom; the Radiological Physics Center (RPC), using TLDs in the standard Elekta ABS plastic calibration phantom (gray phantom), included with the GK; and through a collaborative international calibration survey by the University of Pittsburgh Medical Center (UPMC) using alanine dosimeters, also in the gray phantom. The alanine dosimeters were read by the National Institute of Standards and Technology. Finally, Gafchromic EBT film was used to measure relative output factors and these factors were compared to values reported in the literature as well as new values announced for release by Elekta. The films were exposed in the solid water phantom using an included film insert accessory. Results: Compared to the TG-21 protocol in the solid water phantom, the modified and unmodified TG-51 calibrations resulted in dose rates which were 1.8% and 1.3% lower, respectively. Ratios of the doses measured by third parties to the dose reported showed excellent agreement. MDADS returned ratios of 1.00 and 0.98 for the two TLDs irradiated. The RPC returned a mean ratio of 0.98 of the dose reported and the UPMC alanine study returned a mean ratio of 1.008. Relative output factors were found to be 0.817{+-}0.009 and 0.897{+-}0.008 for the 4 and 8 mm collimators, respectively, which are in excellent agreement with revised Monte Carlo-derived relative output factors Elekta is expected to recommend with the next version of the GK treatment planning software (GAMMAPLAN version 10). Conclusions: The TG-21 dosimetry protocol, performed in a solid water phantom in conjunction with modern dosimeters and phantom material and chamber-dependent factors, can yield an accurate dose measurement in the unique GK treatment geometry. The technique described here can be easily adopted by institutions worldwide since all equipment and instruments used are commercially available, thus reducing the existing interinstitutional variation in GK calibration techniques. Relative output factor measurements made in this same solid water phantom were used to verify the relative output factors provided by Elekta and agreed excellently with output factors expected to be released in conjunction with GAMMAPLAN version 10.

60 APPLIED LIFE SCIENCES↗

Glassy carbon as an absolute intensity calibration standard for small-angle scattering.

Absolute calibration of small-angle scattering (SAS) intensity data (measured in terms of the differential scattering cross section per unit sample volume per unit solid angle) is essential for many important aspects of quantitative SAS analysis, such as obtaining the number density, volume fraction, and specific surface area of the scatterers. It also enables scattering data from different instruments (light, X-ray, or neutron scattering) to be combined, and it can even be useful to detect the existence of artifacts in the experimental data. Different primary or secondary calibration methods are available. In the latter case, absolute intensity calibration requires a stable artifact with the necessary scattering profile. Glassy carbon has sometimes been selected as this intensity calibration standard. Here we review the spatial homogeneity and temporal stability of one type of commercially available glassy carbon that is being used as an intensity calibration standard at a number of SAS facilities. We demonstrate that glassy carbon is sufficiently homogeneous and stable during routine use to be relied upon as a suitable standard for absolute intensity calibration of SAS data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Efficient kinetic thermal inverse modeling for organic material decomposition

The prevalent use of organic materials in manufacturing is a fire safety concern, and motivates the need for predictive thermal decomposition models. A critical component of predictive modeling is numerical inference of kinetic parameters from bench scale data. Currently, an active area of computational pyrolysis research focuses on identifying efficient, robust methods for optimization. This paper demonstrates that kinetic parameter calibration problems can successfully be solved using classical gradient-based optimization. We explore calibration examples that exhibit characteristics of concern: high nonlinearity, high dimensionality, complicated schemes, overlapping reactions, noisy data, and poor initial guesses. The examples demonstrate that a simple, non-invasive change to the problem formulation can simultaneously avoid local minima, avoid computation of derivative matrices, achieve a computational efficiency speedup of 10x, and make optimization robust to perturbations of parameter components. Techniques from the mathematical optimization and inverse problem communities are employed. By re-examining gradient-based algorithms, we highlight opportunities to develop kinetic parameter calibration methods that should outperform current methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calibrations and verifications performed in view of the ILA reinstatement at JET

The calibrations and verifications that are performed in preparation of the ITER-Like antenna (ILA) reinstatement at JET are reviewed. A brief reminder of the ILA system layout is given. The different calibration methods and results are then discussed. They encompass the calibrations of the directional couplers present in the system, the determination of the relation between the capacitor position readings and the capacitance value, the voltage probes calibration inside the antenna housing, the RF cables characterization and the acquisition electronics circuit calibration. Earlier experience with the ILA has shown that accurate calibrations are essential for the control of the full ILA close-packed antenna array, its protection through the S-Matrix Arc Detection and the new second stage matching algorithm to be implemented. Finally the voltage stand-off of the capacitors is checked and the phase range achievable with the system is verified. The system layout is modified as to allow dipole operation over the whole operating frequency range when operating with the 3dB combiner-splitters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Gridded Solar Irradiance Ensemble Prediction System Based on WRF-Solar EPS and the Analog Ensemble

The WRF-Solar Ensemble Prediction System (WRF-Solar EPS) and a calibration method, the analog ensemble (AnEn), are used to generate calibrated gridded ensemble forecasts of solar irradiance over the contiguous United States (CONUS). Global horizontal irradiance (GHI) and direct normal irradiance (DNI) retrievals, based on geostationary satellites from the National Solar Radiation Database (NSRDB) are used for both calibrating and verifying the day-ahead GHI and DNI predictions (GDIP). A 10-member ensemble of WRF-Solar EPS is run in a re-forecast mode to generate day-ahead GDIP for three years. The AnEn is used to calibrate GDIP at each grid point independently using the NSRDB as the “ground truth”. Performance evaluations of deterministic and probabilistic attributes are carried out over the whole CONUS. The results demonstrate that using the AnEn calibrated ensemble forecast from WRF-Solar EPS contributes to improving the overall quality of the GHI predictions with respect to an AnEn calibrated system based only on the deterministic run of WRF-Solar. In fact, the calibrated WRF-Solar EPS’s mean exhibits a lower bias and RMSE than the calibrated deterministic WRF-Solar. Moreover, using the ensemble mean and spread as predictors for the AnEn allows a more effective calibration than using variables only from the deterministic runs. Finally, it has been shown that the recently introduced algorithm of correction for rare events is of paramount importance to obtain the lowest values of GHI from the calibrated ensemble (WRF-Solar EPS AnEn), qualitatively consistent with those observed from the NSRDB.

14 SOLAR ENERGY↗

Composition Quantification of SiGeSn Alloys Through Time-of-Flight Secondary Ion Mass Spectrometry: Calibration Methodologies and Validation With Atom Probe Tomography

Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) is a powerful technique for elemental compositional analysis and depth profiling of materials. However, it encounters the problem of matrix effects that hinder its application. In this work, we introduce a pioneering ToF-SIMS calibration method tailored for SixGeySnz ternary alloys. SixGe1-x and Ge1-zSnz binary alloys with known compositions are used as calibration reference samples. Through a systematic SIMS quantification study of SiGe and GeSn binary alloys, we unveil a linear correlation between secondary ion intensity ratio and composition ratio for both SiGe and GeSn binary alloys, effectively mitigating the matrix effects. Extracted relative sensitivity factor (RSF) value from SixGe1-x (0.07 < x < 0.83) and Ge1-zSnz (0.066 < z < 0.183) binary alloys are subsequently applied to those of SixGeySnz (0.011 < x < 0.113, 0.863 < y < 0.935 and 0.023 < z < 0.103) ternary alloys for elemental compositions quantification. These values are cross-checked by Atom Probe Tomography (APT) analysis, an indication of the great accuracy and reliability of as-developed ToF-SIMS calibration process. Furthermore, the proposed method and its reference sample selection strategy in this work provide a low-cost as well as simple-to-follow calibration route for SiGeSn composition analysis, thus driving the development of next-generation multifunctional SiGeSn-related semiconductor devices.

36 MATERIALS SCIENCE↗

Calibrating page sized Gafchromic EBT3 films

Purpose: The purpose is the development of a novel calibration method for dosimetry with Gafchromic EBT3 films. The method should be applicable for pretreatment verification of volumetric modulated arc, and intensity modulated radiotherapy. Because the exposed area on film can be large for such treatments, lateral scan errors must be taken into account. The correction for the lateral scan effect is obtained from the calibration data itself. Methods: In this work, the film measurements were modeled using their relative scan values (Transmittance, T). Inside the transmittance domain a linear combination and a parabolic lateral scan correction described the observed transmittance values. The linear combination model, combined a monomer transmittance state (T{sub 0}) and a polymer transmittance state (T{sub {infinity}}) of the film. The dose domain was associated with the observed effects in the transmittance domain through a rational calibration function. On the calibration film only simple static fields were applied and page sized films were used for calibration and measurements (treatment verification). Four different calibration setups were considered and compared with respect to dose estimation accuracy. The first (I) used a calibration table from 32 regions of interest (ROIs) spread on 4 calibration films, the second (II) used 16 ROIs spread on 2 calibration films, the third (III), and fourth (IV) used 8 ROIs spread on a single calibration film. The calibration tables of the setups I, II, and IV contained eight dose levels delivered to different positions on the films, while for setup III only four dose levels were applied. Validation was performed by irradiating film strips with known doses at two different time points over the course of a week. Accuracy of the dose response and the lateral effect correction was estimated using the dose difference and the root mean squared error (RMSE), respectively. Results: A calibration based on two films was the optimal balance between cost effectiveness and dosimetric accuracy. The validation resulted in dose errors of 1%-2% for the two different time points, with a maximal absolute dose error around 0.05 Gy. The lateral correction reduced the RMSE values on the sides of the film to the RMSE values at the center of the film. Conclusions: EBT3 Gafchromic films were calibrated for large field dosimetry with a limited number of page sized films and simple static calibration fields. The transmittance was modeled as a linear combination of two transmittance states, and associated with dose using a rational calibration function. Additionally, the lateral scan effect was resolved in the calibration function itself. This allows the use of page sized films. Only two calibration films were required to estimate both the dose and the lateral response. The calibration films were used over the course of a week, with residual dose errors Less-Than-Or-Slanted-Equal-To 2% or Less-Than-Or-Slanted-Equal-To 0.05 Gy.

07 ISOTOPE AND RADIATION SOURCES↗

High precision deflection measurement of microcantilever in an optical pickup head based atomic force microscopy

This paper presents the methodology to measure the precise deflection of microcantilever in an optical pickup head based atomic force microscopy. In this paper, three types of calibration methods have been proposed: full linearization, sectioned linearization, and the method based on astigmatism. In addition, the probe heads for easy calibration of optical pickup head and fast replacement of optical pickup head have been developed. The performances of each method have been compared through a set of experiments and constant height mode operation which was not possible in the optical pickup head based atomic force microscopy has been carried out successfully.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flood hazard model calibration using multiresolution model output

Riverine floods pose a considerable risk to many communities. Improving flood hazard projections has the potential to inform the design and implementation of flood risk management strategies. Current flood hazard projections are uncertain, especially due to uncertain model parameters. Calibration methods use observations to quantify model parameter uncertainty. With limited computational resources, researchers typically calibrate models using either relatively few expensive model runs at high spatial resolutions or many cheaper runs at lower spatial resolutions. This leads to an open question: is it possible to effectively combine information from the high and low resolution model runs? We propose a Bayesian emulation–calibration approach that assimilates model outputs and observations at multiple resolutions. As a case study for a riverine community in Pennsylvania, we demonstrate our approach using the LISFLOOD-FP flood hazard model. Here, the multiresolution approach results in improved parameter inference over the single resolution approach in multiple scenarios. Results vary based on the parameter values and the number of available models runs. Our method is general and can be used to calibrate other high dimensional computer models to improve projections.

multiresolution↗

Multiwavelength digital holography with autocalibration of phase shifts and artificial wavelengths

A novel implementation of lensless multiwavelength digital holography with autocalibration of temporal phase shifts and artificial wavelength is presented. The algorithm we used to calculate the phase shifts was previously proposed [Opt. Lett.29 183 (2004)OPLEDP0146-959210.1364/OL.29.000183] and, to our knowledge, is now used for the first time in lensless holography. Because precise knowledge of the generated artificial wavelength is crucial for absolute measurement accuracy, a simple and efficient method to determine the artificial wavelength directly is presented. The calibration method is based on a simple modification of the experimental setup and needs just one additional image acquisition per wavelength. The results of shape measurement of a metallic test object with a rough surface and steep edges are shown and the measurement accuracy is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗