Search NASA⌕ Search

SEARCH · Search NASA

Results for “Carrier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Interaction Between the Broad-Lined Type Ic Supernova 2012ap and Carriers of Diffuse Interstellar Bands

The diffuse interstellar bands (DIBs) are absorption features observed in optical and near-infrared spectra that are thought to be associated with carbon-rich polyatomic molecules in interstellar gas. However, because the central wavelengths of these bands do not correspond with electronic transitions of any known atomic or molecular species, their nature has remained uncertain since their discovery almost a century ago. Here we report on unusually strong DIBs in optical spectra of the broad- lined Type Ic supernova SN2012ap that exhibit changes in equivalent width over short (. 30 days) timescales. The 4428 A and 6283 A DIB features get weaker with time, whereas the 5780 A feature shows a marginal increase. These nonuniform changes suggest that the supernova is interacting with a nearby source of the DIBs and that the DIB carriers possess high ionization potentials, such as small cations or charged fullerenes. We conclude that moderate-resolution spectra of supernovae with DIB absorptions obtained within weeks of outburst could reveal unique information about the mass-loss environment of their progenitor systems and provide new constraints on the properties of DIB carriers.

broad↗

Evidence of Carrier Localization in InAsSb/InSb Digital Alloy nBn Detector

Recently we have demonstrated a novel method of extending the cut-off wavelength of InAsSb nBn detectors, by incorporating a series of monolayers of InSb. Here we study photoluminescence and minority carrier lifetime of this InAsSb/InSb digital alloy. While increasing temperature from 15 K to 40 K we show a 14 meV blue shift of the photoluminescence peak energy and a decrease in lifetime. This deviation from the expected Varshni empirical relation indicates strong carrier localization. We contrast to photoluminescence and lifetime results in bulk InAsSb. We discuss implications of this localization for design of digital alloy InAsSb/InSb nBn detectors.

Pepper, Brian J.↗

Precise Kinematic Positioning with Simultaneous GPS Pseudorange and Carrier Phase Measurements

This paper investigates three precise kinematic positioning techniques with simultaneous GPS pseudorange and carrier phase measurements. These techniques are simple, efficient, and well suited for real-time positioning applications. A simulation/covariance analysis is carried out comparing the relative performance of these techniques. The analysis indicates that GPS carrier phase measurements significantly strengthen kinematic positioning. When wide-area differential GPS for reducing SA clock errors and GPS ephemeris errors is available, a low Earth orbiting satellite can be positioned to 0.5-0.8 m in accuracy (3-D RSS). The accuracy is superior to positioning with pseudorange measurements alone by a factor of 2 to 3. Relative positioning performance and complexity between the three techniques are compared.

['Kinematic↗

Frequency comparisons via GPS carrier-phase: jump processing, temperature compensation and zero/short-baseline noise-floors

GPS carrier-phase receivers have been used to produce high quality time/frequency comparisons between clocks and frequency standards. Current ways of processing the carrier-phase data, however, result in phase jumps and data gaps that make the data difficult to use effectively and repeatedly for long datasets. In addition, temperature fluctuations generally perturb receiver output detrimentally. We describe the steps of a simple but effective automated algorithm for comparing frequencies that can compensate for data gaps, day boundary jumps, and other phase jumps as well as for temperature disturbances. We describe process features and focus on zero-baseline noise-floors, measuring Allan deviations of the Deep Space Atomic Clock mission’s receiver down to 1x10-17 at 5x105 seconds, with an upper confidence level of 3x10-17. The zero-baseline noise floors we present give confidence in our algorithm and temperature compensation’s robustness.

Diener, William A.↗

Utilization of peptide carrier system to improve intestinal absorption: targeting prolidase as a prodrug-converting enzyme

The feasibility of targeting prolidase as a peptide prodrug-converting enzyme has been examined. The enzymatic hydrolysis by prolidase of substrates for the peptide transporter L-alpha-methyldopa-pro and several dipeptide analogues without an N-terminal alpha-amino group (phenylpropionylproline, phenylacetylproline, N-benzoylproline, and N-acetylproline) was investigated. The Michaelis-Menten parameters Km and Vmax for L-alpha-methyldopa-pro are 0.09 +/- 0.02 mM and 3.98 +/- 0.25 mumol/min/mg protein, respectively. However, no hydrolysis of the dipeptide analogues without an N-terminal alpha-amino group is observed, suggesting that an N-terminal alpha-amino group is required for prolidase activity. These results demonstrate that prolidase may serve as a prodrug-converting enzyme for the dipeptide-type prodrugs, utilizing the peptide carrier for transport of prodrugs into the mucosal cells and prolidase, a cytosolic enzyme, to release the drug. However, a free alpha-amino group appears to be necessary for prolidase hydrolysis.

NASA Discipline Regulatory Physiology↗

Suppressed Carrier Synchronizers for ISI Channels

We demonstrate a class of suppressed carrier synchronization loops that are motivated by MAP estimation theory and in the presence of ISI outperform the conventional I-Q loop which is designed on the basis of zero ISI (wideband assumption). The measure of comparison used is the so-called.

synchronization loops↗