Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cavity reactors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Nuclear characteristics of a fissioning uranium plasma test reactor with light-water cooling

An analytical study was performed to determine a design configuration for a cavity test reactor. Test section criteria were that an average flux of 10 to the 15th power neutrons/sq cm/sec (E less than or equal to 0.12 eV) be supplied to a 61-cm-diameter spherical cavity at 200-atm pressure. Design objectives were to minimize required driver power, to use existing fuel-element technology, and to obtain fuel-element life of 10 to 100 full-power hours. Parameter calculations were made on moderator region size and material, driver fuel arrangement, control system, and structure in order to determine a feasible configuration. Although not optimized, a configuration was selected which would meet design criteria. The driver fuel region was a cylindrical annular region, one element thick, of 33 MTR-type H2O-cooled elements (Al-U fuel plate configuration), each 101 cm long. The region between the spherical test cavity and the cylindrical driver fuel region was Be (10 vol. % H2O coolant) with a midplane dimension of 8 cm. Exterior to the driver fuel, the 25-cm-thick cylindrical and axial reflectors were also Be with 10 vol. % H2O coolant. The entire reactor was contained in a 10-cm-thick steel pressure vessel, and the 200-atm cavity pressure was equalized throughout the driver reactor. Fuel-element life was 50 hr at the required driver power of 200 MW. Reactor control would be achieved with rotating poison drums located in the cylindrical reflector region. A control range of about 18 percent delta k/k was required for reactor operation.

Whitmarsh, C. L., Jr.↗

High-sensitivity fast neutron detector KNK-2-7M

The construction of the fast neutron detector KNK-2-7M is briefly described. The results of the study of the detector in the pulse-counting mode are given for the fissions of {sup 237}Np nuclei in the radiator of the neutron-sensitive section and in the current mode with the separation of sectional currents of functional sections. The possibilities of determining the effective number of {sup 237}Np nuclei in the radiator of the neutronsensitive section are considered. The diagnostic possibilities of the detector in the counting mode are shown by example of the analysis of the reference data from the neutron-field characteristics in the working hall of the BR-K1 reactor. The diagnostic possibilities of the detector in the current operating mode are shown by example of the results of measuring the {sup 237}Np-fission intensity in the BR-K1 reactor power start-ups implemented in the mode of fission-pulse generation on delayed neutrons at the detector arrangement inside the reactor core cavity under conditions of a wide variation of the reactor radiation field.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Flowing gas, non-nuclear experiments on the gas core reactor

Variations in cavity wall and injection configurations of the gas core reactor were aimed at establishing flow patterns that give a maximum of the nuclear criticality eigenvalue. Correlation with the nuclear effect was made using multigroup diffusion theory normalized by previous benchmark critical experiments. Air was used to simulate the hydrogen propellant in the flow tests, and smoked air, argon, or Freon to simulate the central nuclear fuel gas. Tests were run both in the down-firing and upfiring directions. Results showed that acceptable flow patterns with volume fraction for the simulated nuclear fuel gas and high flow rate ratios of propellant to fuel can be obtained. Using a point injector for the fuel, good flow patterns are obtained by directing the outer gas at high velocity long the cavity wall, using louvered injection schemes. Recirculation patterns were needed to stabilize the heavy central gas when different gases are used.

Kunze, J. F.↗

Enhanced boron doping for diamond growth in cylindrical CVD reactors using a Faraday cage

We report on the use of 3D-printed titanium Faraday cages in a cylindrical resonant cavity CVD reactor for the growth of heavily boron-doped single-crystalline superconducting diamond. We show that the cage enhances boron doping uniformity and provides control of the doping efficiency and growth rate by varying the distance between the plasma and the diamond surface. Using finite element modelling, we demonstrate that the Faraday cage focuses the electric field at the top of the cage whilst also suppressing the electric field inside the cage, thereby pinning the plasma at a fixed height above the sample. This eliminates plasma “hot spots” at the edges of the sample and creates a more uniform plasma electron and hydrogen radical distribution over the sample, resulting in a more uniform boron incorporation.

Boron doped diamond↗

A Forward Feedback Control Scheme for a Solar Thermochemical Moving Bed Counter-Current Flow Reactor

Abstract Pelletized thermochemical energy storage media has a potential for long-duration energy storage. Production of solid-state energy storage media can be done within a cavity chemical reactor that captures concentrated solar radiation from a solar thermal field. The temperature stability of a solar reactor is directly influenced by the solar flux intercepted. This paper presents a low-order physical model to simulate the dynamic response of temperature inside a tubular plug-flow reactor prototype. Solid granular particles are fed to the reactor from the top whereas a counter-current flowing gas enters the reactor from the bottom. An in-house code was developed to model transient heat transfer of the reactor wall, gas, and moving particles. The model was preliminarily validated with packed beds for different temperature ranges and two gas flowrates. Dynamic response of the reactor temperature is simulated for different input power and gas/particle flowrates. The results show that the system response can be controlled efficiently by utilizing input power (solar flux) as a control parameter. A conventional proportional integral (PI) controller is designed to control the temperature inside the reactor and to maintain it during the solar flux intermittency. The controller parameters are tuned using the Ziegler–Nichols method to ensure optimal system response. The results show that the feedback control model is successful in tracking different reference reactor temperatures within a reasonable settling time of 30 min and eliminated overshoot. This study can be extended to include a hybrid reactor with a multi-input, multi-output variable system.

Energy & Fuels↗

Design of Microwave Resonant Cavity Transducer. Development of sensor performance model of microwave cavity flow meter for advanced reactor high temperature fluids

High-temperature fluid reactors, such as molten salt cooled reactors (MSCR) and sodium fast reactors (SFR), are a promising advanced reactor option. Measurement of high-temperature fluid process variables, in particular the flow inside the pressure vessel, is a challenging task because of harsh environment, which includes high radiation, high temperature, and contact with highly corrosive coolant fluid. We are investigating a microwave cavity-based transducer for high-temperature fluid flow sensing. This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. A cavity is characterized by its resonant frequencies. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. Feasibility of the flow sensor is evaluated with signal sensitivity using COMSOL computer simulations. A right cylinder geometry stainless steel cavity with dimeter of 0.8in was investigated. We choose membrane thickness of 10mil, so that corrosion anticipated to proceed at the rate of 1mil/year in liquid sodium would affect no more than 10% of the membrane. Using the properties of liquid sodium fluid, and stainless-steel material property values at 500oC, we calculate frequency shift for a range of values of fluid velocity from 0.5m/s to 2m/s. Results of computer simulations indicate measurable sensitivity to flow for this cavity design. Following these simulations, we have developed a preliminary design for fabrication of a transducer operating in microwave K-band for proof-of-principle tests.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Gas-core reactor power transient analysis

The gas core reactor is a proposed device which features high temperatures. It has applications in high specific impulse space missions, and possibly in low thermal pollution MHD power plants. The nuclear fuel is a ball of uranium plasma radiating thermal photons as opposed to gamma rays. This thermal energy is picked up before it reaches the solid cavity liner by an inflowing seeded propellant stream and convected out through a rocket nozzle. A wall-burnout condition will exist if there is not enough flow of propellant to convect the energy back into the cavity. A reactor must therefore operate with a certain amount of excess propellant flow. Due to the thermal inertia of the flowing propellant, the reactor can undergo power transients in excess of the steady-state wall burnout power for short periods of time. The objective of this study was to determine how long the wall burnout power could be exceeded without burning out the cavity liner. The model used in the heat-transfer calculation was one-dimensional, and thermal radiation was assumed to be a diffusion process.

Kascak, A. F.↗

Individual RF Test Results of the Cavities Used in the First US-built ILC-type Cryomodule

Eight 1.3-GHz, nine-cell SRF cavities have been installed in a cryomodule intended to demonstrate the ILC design goal of 31.5 MV/m. These cavities all underwent two types of individual RF testing: a low-power continuous-wave test of the 'bare' cavity and a high-power pulsed test of the 'dressed' cavity. Presented here is a discussion of the results from these tests and a comparison of their performance in the two configurations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

ANALYSIS OF HIGH FIELD NON-LINEAR LOSSES ON SRF SURFACES DUE TO SPECIFIC TOPOGRAPHIC ROUGHNESS

The high-field performance of SRF cavities will eventually be limited by the realization of fundamental material limits, whether it is Hc1 or Hsh, or some derivative thereof, at which the superconductivity is lost. Before reaching this fundamental field limit at the macro level, it must be encountered at localized, perhaps microscopic, sites of field enhancement due to local topography. If such sites are small enough, they may produce thermally stabilized normal-conducting regions which contribute non-linear losses when viewed from the macro resonant field perspective, and thus produce degradation in Q0. We have undertaken a calculation of local surface magnetic field enhancement from specific fine topographic structure by conformal mapping method and numerically. A solution of the resulting normal conducting volume has been derived and the corresponding RF Ohmic loss simulated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High-resolution wall temperature measurements with distributed fiber optic sensors

Conventional approaches of surface temperature measurement are often unreliable, and other methods may not be practical in closed, high-temperature spaces. In this study, surface temperature measurements of the cooling panel of a natural circulation facility were performed with fiber optic distributed temperature sensors (DTS). High resolution surface temperature profiles of the cooling panel were acquired under two steady experimental conditions, and compared with measurements performed with nearby thermocouples. The total measurement error of the DTS results presented has been estimated to be ±4.4 °C. The findings reflected herein show that these DTS can reasonably measure surface temperature when installed with the methods developed in this study. Through the analysis of the DTS data collected, the interesting behavior of the cooling panel was revealed, providing new insights on the system's behavior that may be beneficial to the design and optimization of such heat transfer devices. These sensors can also provide the measurement density necessary for validation efforts with highly-resolved prediction methods such as finite element analysis (FEA) or computational fluid dynamics (CFD).

47 OTHER INSTRUMENTATION↗

Solid State Solar Thermochemical Fuel (SoFuel) for Long Duration Storage

Efficient thermal storage systems, when coupled with renewable energy, enable the decarbonization of numerous industrial processes requiring high temperature steam or air, and provide a path for seasonal building heating, especially for colder climates. Existing thermal storage systems face a significant challenge due to losses inherent to all high temperature systems. A viable route to long-term storage is to use thermochemical reactions to convert concentrated solar energy to a fuel that is shelf-stable and can be stored at room temperature, thus eliminating losses associated with high temperature storage. The Solid-State Solar Thermochemical Fuel (SoFuel) technology developed by Michigan State University, Oregon State University, and Mississippi State University provides reactors and processes with minimal sensible heat losses and allows storing solar energy as a solid-state fuel at room temperature for long duration. The production of SoFuel occurs within a cylindrical cavity reduction chemical reactor that captures concentrated solar radiation from a solar field. Reactive magnesium manganese oxide (Mg-Mn-O) resides within the cylindrical cavity chemical reactor and undergoes thermal reduction as the temperature exceeds 1350°C. The thermally reduced Mg-Mn-O pellets (the SoFuel) are cooled down through a recuperative process and stored within a bin until used. The SoFuel can directly supply up to 1100°C heat to an adjacent power plant for electricity generation or industrial heating. Oxidation of SoFuel pellets occurs in a counter flow reactor and supplies heat to the user for electricity generation or industrial processing, after which the fuel is returned to the concentrating solar field where it is regenerated for re-use. Both reactors can be controlled well using a variety of strategies. With the low cost of the material, its cyclability, and the possibility of using the pelletized with on-sun reactors, or with electricity that would be curtailed, this project offers a viable option of medium- and long-term thermal energy storage.

14 SOLAR ENERGY↗

Solid State Solar Thermochemical Fuel (SoFuel) for Long Duration Storage

Efficient thermal storage systems, when coupled with renewable energy, enable the decarbonization of numerous industrial processes requiring high temperature steam or air, and provide a path for seasonal building heating, especially for colder climates. Existing thermal storage systems face a significant challenge due to losses inherent to all high temperature systems. A viable route to long-term storage is to use thermochemical reactions to convert concentrated solar energy to a fuel that is shelf-stable and can be stored at room temperature, thus eliminating losses associated with high temperature storage. The Solid-State Solar Thermochemical Fuel (SoFuel) technology developed by Michigan State University, Oregon State University, and Mississippi State University provides reactors and processes with minimal sensible heat losses and allows storing solar energy as a solid-state fuel at room temperature for long duration. The production of SoFuel occurs within a cylindrical cavity reduction chemical reactor that captures concentrated solar radiation from a solar field. Reactive magnesium manganese oxide (Mg-Mn-O) resides within the cylindrical cavity chemical reactor and undergoes thermal reduction as the temperature exceeds 1350°C. The thermally reduced Mg-Mn-O pellets (the SoFuel) are cooled down through a recuperative process and stored within a bin until used. The SoFuel can directly supply up to 1100C heat to an adjacent power plant for electricity generation or industrial heating. Oxidation of SoFuel pellets occurs in a counter flow reactor and supplies heat to the user for electricity generation or industrial processing, after which the fuel is returned to the concentrating solar field where it is regenerated for re-use. Both reactors can be controlled well using a variety of strategies. With the low cost of the material, its cyclability, and the possibility of using the pelletized with on-sun reactors, or with electricity that would be curtailed, this project offers a viable option of medium- and long-term thermal energy storage.

25 ENERGY STORAGE↗

ACRRF High-Bay Dose Calculations using MCNP (Part A)

Analytical tools and models have been developed as a starting point for directly assessing dose in the Annular Core Research Reactor Facility (ACRRF) due to reactor operation. Key results include peak dose along the Central Cavity (CC) centerline (beamline) at the cavity level, dose throughout the High-Bay (HB), and dose on the facility roof for partially-shielded reactor operation where the 4” insert is removed from the CC Shield Plug (SP). Model results in the beamline are benchmarked against measured doses from passive dosimetry evaluations. Personnel total (neutron and gamma) dose in the ACRRF HB is calculated using Monte Carlo N-Particle (MCNP). Various CC and SP configurations are analyzed, including unshielded (no SP) and partially shielded (SP installed but 4” insert removed). Novel application of Variance Reduction (VR) techniques, namely the Surface Source Write (SSW) and Surface Source Read (SSR) capabilities in MCNP, enable impressive resolution (in a Monte Carlo modeling sense) of dose throughout much the facility. The VR techniques reduce stochastic error for challenging tallies, with more advanced techniques explored in the companion to this report (Part B) [1]. Supplementary studies (including a verification analysis) and pedagogic evaluations in Part B involve neutron spectra, angular distributions, and the dose impact of facility characteristics. With the SP 4” insert removed and the Lead-Boron (44”) Bucket (LB–44) in the reactor cavity, Total Effective Dose (TED) within the CC beamline is ≈140 rem per 300 MJ of reactor yield (or 3900 rem per hour at 100% Steady-State (SS) power). With no SP (unshielded) and a Free-Field (FF) cavity, TED within the beamline is ≈610 rem per 300 MJ (or 17000 rem per hour at 100% SS power). Due to the predicted collimation of radiation by the reactor pool (and partial SP, if present), beamline dose is much greater than the scattered radiation field surrounding the cavity and reactor tank. Comparisons are made to beamline dosimetry measurements to validate the model. Model predictions agree reasonably well (⪅10%) with measured quantities of neutron fluence, gamma fluence, and spectral metrics. Away from the beamline, comparisons made to previous dose measurements in the HB agreement within an order of magnitude.

61 RADIATION PROTECTION AND DOSIMETRY↗

Performance Capability of Single-Cavity Vortex Gaseous Nuclear Rockets

An analysis was made to determine the maximum powerplant thrust-to-weight ratio possible with a single-cavity vortex gaseous reactor in which all the hydrogen propellant must diffuse through a fuel-rich region. An assumed radial temperature profile was used to represent conduction, convection, and radiation heat-transfer effects. The effect of hydrogen property changes due to dissociation and ionization was taken into account in a hydrodynamic computer program. It is shown that, even for extremely optimistic assumptions of reactor criticality and operating conditions, such a system is limited to reactor thrust-to-weight ratios of about 1.2 x 10(exp -3) for laminar flow. For turbulent flow, the maximum thrust-to-weight ratio is less than 10(exp -3). These low thrusts result from the fact that the hydrogen flow rate is limited by the diffusion process. The performance of a gas-core system with a specific impulse of 3000 seconds and a powerplant thrust-to-weight ratio of 10(exp -2) is shown to be equivalent to that of a 1000-second advanced solid-core system. It is therefore concluded that a single-cavity vortex gaseous reactor in which all the hydrogen must diffuse through the nuclear fuel is a low-thrust device and offers no improvement over a solid-core nuclear-rocket engine. To achieve higher thrust, additional hydrogen flow must be introduced in such a manner that it will by-pass the nuclear fuel. Obviously, such flow must be heated by thermal radiation. An illustrative model of a single-cavity vortex system employing supplementary flow of hydrogen through the core region is briefly examined. Such a system appears capable of thrust-to-weight ratios of approximately 1 to 10. For a high-impulse engine, this capability would be a considerable improvement over solid-core performance. Limits imposed by thermal radiation heat transfer to cavity walls are acknowledged but not evaluated. Alternate vortex concepts that employ many parallel vortices to achieve higher hydrogen flow rates offer the possibility of sufficiently high thrust-to-weight ratios, if they are not limited by short thermal-radiation path lengths.

Ragsdale, Robert G.↗

Gaseous-fuel nuclear reactor research for multimegawatt power in space

In the gaseous-fuel reactor concept, the fissile material is contained in a moderator-reflector cavity and exists in the form of a flowing gas or plasma separated from the cavity walls by means of fluid mechanical forces. Temperatures in excess of structural limitations are possible for low-specific-mass power and high-specific-impulse propulsion in space. Experiments have been conducted with a canister filled with enriched UF6 inserted into a beryllium-reflected cavity. A theoretically predicted critical mass of 6 kg was measured. The UF6 was also circulated through this cavity, demonstrating stable reactor operation with the fuel in motion. Because the flowing gaseous fuel can be continuously processed, the radioactive waste in this type of reactor can be kept small. Another potential of fissioning gases is the possibility of converting the kinetic energy of fission fragments directly into coherent electromagnetic radiation, the nuclear pumping of lasers. Numerous nuclear laser experiments indicate the possibility of transmitting power in space directly from fission energy. The estimated specific mass of a multimegawatt gaseous-fuel reactor power system is from 1 to 5 kg/kW while the companion laser-power receiver station would be much lower in specific mass.

Thom, K.↗

MELCOR Accident Progression and Source Term Demonstration Calculations for a Heat Pipe Reactor

MELCOR is an integrated thermal hydraulics, accident progression, and source term code for reactor safety analysis that has been developed at Sandia National Laboratories for the United States Nuclear Regulatory Commission (NRC) since the early 1980s. Though MELCOR originated as a light water reactor (LWR) code, development and modernization efforts have expanded its application scope to includ e non-LWR reactor concepts. Current MELCOR development efforts include providing the NRC with the analytical capabilities to support regulatory readiness for licensing non-LWR techno logies under Strategy 2 of the NRC?s near- term Implementation Action Plans. Beginning with the Next Generation Nuclear Project (NGNP), MELCOR has undergone a range of enha ncements to provide analytical capabilities for modeling the spectrum of advanced non-LWR concepts. This report describes the generic plant model developed to demonstrate MELCOR capabilities to perform heat pipe reactor (HPR) safety evaluations. The generic plant mode l is based on a publicly-available Los Alamos National Laboratory (LANL) Megapower design as modified in the Idaho National Laboratory (INL) Design A description. For plant aspects (e.g., reactor building size and leak rate) that are not described in the LANL and INL references , the analysts made assumptions needed to construct a MELCOR full-plant model. The HP R uses high assay, low-enrichment uranium (HALEU) fuel with steel cladding that uses heat pipes to transfer heat to a secondary Brayton air cycle. The core region is surrounded by a stainless-steel shroud, alumina reflector, core barrel and boron carbide neutron shield. The reactor is secured inside a below-grade cavity, with the operating floor located above the cavity. Example calculations are performed to show the plant response and MELCOR capabilities to characterize a range of accident conditions. The accidents selected for evaluation consider a range of degraded and failed modes of operation for key safety functions providing re activity control, the primary and secondary system heat removal, and the effectiveness of th e confinement natural circulation flow into the reactor cavity (i.e., a flow blockage).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Observation of Downward Facing Pool Boiling on a Hemispherical Vessel under External Reactor Vessel Cooling

It is a great challenge to ensure the safety of nuclear power plant during a severe accident. One of the major concerns is to overheat the reactor core which potentially may create a nuclear crisis if the core cooling fails. The concept of In-vessel retention (IVR) by passive external reactor vessel cooling (ERVC) in a flooded cavity of pressurized water reactor (PWR) is a viable and effective approach to retain radioactive core melt within the reactor pressure vessel (RPV). As long as the heat flux at the lower head of the RPV is lower than the critical heat flux (CHF) limit at the corresponding point, nucleate boiling will be the prevailing regime. In that case, the temperature of outer surface can be maintained near the saturated temperature of water such that the reactor vessel is able to be sufficiently cooled to sustain its thermal and structural integrity. Owing to the practical significance of this IVR-ERVC concept, there were many experimental and theoretical studies to investigate the two-phase flow natural circulation phenomena including the effect of inclination angle on the CHF, based on which many different empirical or semiempirical correlations were developed for CHF by fitting the experimental results. For the engineering applications, reactor-scale facilities such as ULPU series, KAIST facility, CYBL and FIRM were built to experimentally verify and validate the feasibility of ERVC for different design of reactors. Besides, for the research on physical mechanism of downward facing pool boiling, laboratory-scale experiments such as DELTA, CASA and SBLB were performed to visually and theoretically simulate the process of IVR-ERVC. All of the aforementioned test facilities and experiments provided a simulation of the downward facing boiling process and experimental study on the CHF limits during the ERVC conditions of different types of reactors. There were also some visualized investigations on the two-phase flow behavior in both quenching and steady state experiments. In this study, a scale-down three-dimensional downward facing pool boiling facility (iSBLB) was built to investigate the two phase natural circulation flow characteristics during the ERVC process. The general morphologies of vapor mass at different locations were visually recorded using the high-speed camera. The observation results showed that vapor behavior along the hemispherical curved surface was periodical. The boiling phenomenon was quite different from those on all other surface orientations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗