Search NASA⌕ Search

SEARCH · Search NASA

Results for “Coherent optical effects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

204 records · Page 12

Absolute Position of Targets Measured Through a Chamber Window Using Lidar Metrology Systems

Lidar is a useful tool for taking metrology measurements without the need for physical contact with the parts under test. Lidar instruments are aimed at a target using azimuth and elevation stages, then focus a beam of coherent, frequency modulated laser energy onto the target, such as the surface of a mechanical structure. Energy from the reflected beam is mixed with an optical reference signal that travels in a fiber path internal to the instrument, and the range to the target is calculated based on the difference in the frequency of the returned and reference signals. In cases when the parts are in extreme environments, additional steps need to be taken to separate the operator and lidar from that environment. A model has been developed that accurately reduces the lidar data to an absolute position and accounts for the three media in the testbed air, fused silica, and vacuum but the approach can be adapted for any environment or material. The accuracy of laser metrology measurements depends upon knowing the parameters of the media through which the measurement beam travels. Under normal conditions, this means knowledge of the temperature, pressure, and humidity of the air in the measurement volume. In the past, chamber windows have been used to separate the measuring device from the extreme environment within the chamber and still permit optical measurement, but, so far, only relative changes have been diagnosed. The ability to make accurate measurements through a window presents a challenge as there are a number of factors to consider. In the case of the lidar, the window will increase the time-of-flight of the laser beam causing a ranging error, and refract the direction of the beam causing angular positioning errors. In addition, differences in pressure, temperature, and humidity on each side of the window will cause slight atmospheric index changes and induce deformation and a refractive index gradient within the window. Also, since the window is a dispersive media, the effect of both phase and group indices have to be considered. Taking all these factors into account, a method was developed to measure targets through multiple regions of different materials and produce results that are absolute measurements of target position in three-dimensional space, rather than simply relative position. The environment in which the lidar measurements are taken must be broken down into separate regions of interest and each region solved for separately. In this case, there were three regions of interest: air, fused silica, and vacuum. The angular position of the target inside the chamber is solved using only phase index and phase velocity, while the ranging effects due to travel from air to glass to vacuum/air are solved with group index and group velocity. When all parameters are solved simultaneously, an absolute knowledge of the position of each target within an environmental chamber can be derived. Novel features of this innovation include measuring absolute position of targets through multiple dispersive and non-dispersive media, deconstruction of lidar raw data from a commercial off-the-shelf unit into reworkable parameters, and use of group velocities to reduce range data. Measurement of structures within a vacuum chamber or other harsh environment, such as a furnace, may now be measured as easily as if they were in an ambient laboratory. This analysis permits transformation of the raw data into absolute spatial units (e.g., mm). This technique has also been extended to laser tracker, theodolite, and cathetometer measurements through refractive media.

Kubalak, David↗

Accretion Flows in Magnetic White Dwarf Systems

We received Type A and B funding under the NASA Astrophysics Data Program for the analysis and interpretation of hard x-ray data obtained by the Rossi X-ray Timing Explorer and other NASA sponsored missions for Intermediate Polars (IPS) and Polars. For some targets, optical data was available. We reduced and analyzed the X-ray spectra and the X-ray and optical (obtained at the Cerro Tololo Inter-American Observatory) timing data using detailed shock models (which we constructed) to place constraints on the properties of the accreting white dwarfs, the high energy emission mechanisms of white dwarfs, and the large-scale accretion flows of Polars and IPS. IPS and Polars are white dwarf mass-transfer binaries, members of the larger class of cata,clysmic variables. They differ from the bulk of the cataclysmic variables in that they contain strongly magnetic white dwarfs; the white dwarfs in Polars have B, = 7 to 230 MG and those in IPS have B, less than 10 MG. The IPS and Polars are both examples of funneled accretion flows in strong magnetic field systems. The IPS are similar to x-ray pulsars in that accretion disks form in the systems which are disrupted by the strong stellar magnetic fields of the white dwarfs near the stellar surface from where the plasma is funneled to the surface of the white dwarf. The localized hot spots formed at the footpoints of the funnels coupled with the rotation of the white dwarf leads to coherent pulsed x-ray emission. The Polars offer an example of a different accretion topology; the magnetic field of the white dwarf controls the accretion flow from near the inner Lagrangian point of the system directly to the stellar surface. Accretion disks do not form. The strong magnetic coupling generally leads to synchronous orbital/rotational motion in the Polars. The physical system in this sense resembles the Io/Jupiter system. In both IPS and Polars, pulsed emission from the infrared to x-rays is produced as the funneled flows merge onto the white dwarfs through the formation of strong radiating shock waves. A comparative study of the IPS and Polars can elucidate the primary effects of the magnetic fields on the dynamics and thermodynamics in accreting white dwarf systems.

Imamura, James N.↗

A Compact, Tunable Near-UV Source for Quantitative Microgravity Combustion Diagnostics

There is a need for improved optical diagnostic methods for use in microgravity combustion research. Spectroscopic methods with fast time response that can provide absolute concentrations and concentration profiles of important chemical species in flames are needed to facilitate the understanding of combustion kinetics in microgravity. Although a variety of sophisticated laser-based diagnostics (such as planar laser induced fluorescence, degenerate four wave mixing and coherent Raman methods) have been applied to the study of combustion in laboratory flames, the instrumentation associated with these methods is not well suited to microgravity drop tower or space station platforms. Important attributes of diagnostic systems for such applications include compact size, low power consumption, ruggedness, and reliability. We describe a diode laser-based near-UV source designed with the constraints of microgravity research in mind. Coherent light near 420 nm is generated by frequency doubling in a nonlinear crystal. This light source is single mode with a very narrow bandwidth suitable for gas phase diagnostics, can be tuned over several 1/cm and can be wavelength modulated at up to MHz frequencies. We demonstrate the usefulness of this source for combustion diagnostics by measuring CH radical concentration profiles in an atmospheric pressure laboratory flame. The radical concentrations are measured using wavelength modulation spectroscopy (WMS) to obtain the line-of-sight integrated absorption for different paths through the flame. Laser induced fluorescence (LIF) measurements are also demonstrated with this instrument, showing the feasibility of simultaneous WMS absorption and LIF measurements with the same light source. LIF detection perpendicular to the laser beam can be used to map relative species densities along the line-of-sight while the integrated absorption available through WMS provides a mathematical constraint on the extraction of quantitative information from the LIF data. Combining absorption with LIF - especially if the measurements are made simultaneously with the same excitation beam - may allow elimination of geometrical factors and effects of intensity fluctuations (common difficulties with the analysis of LIF data) from the analysis.

Peterson, K. A.↗

SPACEFLIGHT ASSOCIATED NEURO-OCULAR SYNDROME (SANS): 2023 CLINICAL UPDATE

INTRODUCTION Spaceflight Associated Neuro-ocular Syndrome (SANS) is a condition unique to long-duration spaceflight, with an unclear pathogenesis and pathophysiology, and no perfect terrestrial analog. Approximately 66% of long duration spaceflight (LDSF) astronauts present with the earliest indication of SANS, which is defined as development of any of the following signs in at least one eye during or immediately following spaceflight: 1) optic disc edema (ODE; represented by an increase of ≥ 20 microns in peripapillary total retinal thickness [ΔTRT]); 2) chorioretinal folds; 3) globe flattening; and 4) excessive shift in refractive error (≥ +0.75D). Each of these signs presents potential risk to a crewmember’s vision and mission effectiveness, with ODE posing the highest risk overall. It is not yet known what severity and/or duration of these signs might lead to acute or permanent impacts to ocular anatomy or visual performance. Brain anatomical changes also occur during long-duration spaceflight and are being monitored in the astronaut population; however, these changes have not yet been associated with functional decrements or with SANS. An update will be provided on the latest SANS clinical analyses, diagnostics, and program initiatives. METHODS Data were obtained from clinical records and SANS subject matter experts (SMEs) to compile a SANS clinical update. Areas of interest include: 1) prevalence of SANS signs, 2) defining clinical thresholds for SANS, and 3) an overview of current and planned SANS clinical efforts. DISCUSSION SANS Sign Prevalence: Analysis at the time of this abstract submission indicates that the approximate prevalence of primary SANS findings in USOS LDSF crewmembers is: 64% for ODE (≥ 20-micron ΔTRT), 15% for chorioretinal folds, 26% for globe flattening, and 14% for hyperopic shifts in refractive error (≥ +0.75D). Clinical Thresholds:  The Earliest Indication of SANS was presented publicly for the first time at the 2020 NASA Human Research Program Investigators’ Workshop. See definition in Introduction section (above).  Clinically Concerning SANS – Development of any of the following signs during or immediately following spaceflight: 1) ODE (≥ 55-micron ΔTRT* and/or Frisèn grade ≥1*), 2) sharp chorioretinal folds in the vicinity of the macula, or 3) moderate globe flattening.  Pathological SANS with an Acute Functional Impact – Development of any of the following signs/symptoms during or immediately following spaceflight: 1) visual field loss (e.g., enlarged blindspot), 2) distorted centralvision, or 3) shift in refractive error beyond power of available correction (e.g., “space anticipation glasses”).  Pathological SANS affecting Long-Term Health – Development of any of the following signs/symptoms during or following spaceflight: 1) permanent visual field loss, 2) reduced retinal nerve fiber layer (RNFL) thickness, 3) permanently distorted central vision, 4) atrophy of retinal pigment epithelium (RPE) or photoreceptors, or 5) choroidal neovascularization. Current & Planned Clinical Efforts (accurate at time of abstract submission): All SANS diagnostic hardware are performing nominally onboard the International Space Station: vision screening, fundoscope, optical coherence tomography (OCT) device, ultrasound, and tonometer. The Goggle-Based Visual Field (GBVF) device is nearing completion of its clinical validation study at Ohio State University and is planned for parabolic flight testing in fiscal year 2023 (FY23); pending positive results, this sequence may pave the way towards an ISS technology demonstration in FY24.

T J Brunstetter↗

Aligning Arrays of Lenses and Single-Mode Optical Fibers

A procedure now under development is intended to enable the precise alignment of sheet arrays of microscopic lenses with the end faces of a coherent bundle of as many as 1,000 single-mode optical fibers packed closely in a regular array (see Figure 1). In the original application that prompted this development, the precise assembly of lenses and optical fibers serves as a single-mode spatial filter for a visible-light nulling interferometer. The precision of alignment must be sufficient to limit any remaining wavefront error to a root-mean-square value of less than 1/10 of a wavelength of light. This wavefront-error limit translates to requirements to (1) ensure uniformity of both the lens and fiber arrays, (2) ensure that the lateral distance from the central axis of each lens and the corresponding optical fiber is no more than a fraction of a micron, (3) angularly align the lens-sheet planes and the fiber-bundle end faces to within a few arc seconds, and (4) axially align the lenses and the fiber-bundle end faces to within tens of microns of the focal distance. Figure 2 depicts the apparatus used in the alignment procedure. The beam of light from a Zygo (or equivalent) interferometer is first compressed by a ratio of 20:1 so that upon its return to the interferometer, the beam will be magnified enough to enable measurement of wavefront quality. The apparatus includes relay lenses that enable imaging of the arrays of microscopic lenses in a charge-coupled-device (CCD) camera that is part of the interferometer. One of the arrays of microscopic lenses is mounted on a 6-axis stage, in proximity to the front face of the bundle of optical fibers. The bundle is mounted on a separate stage. A mirror is attached to the back face of the bundle of optical fibers for retroreflection of light. When a microscopic lens and a fiber are aligned with each other, the affected portion of the light is reflected back by the mirror, recollimated by the microscopic lens, transmitted through the relay lenses and the beam compressor/expander, then split so that half goes to a detector and half to the interferometer. The output of the detector is used as a feedback control signal for the six-axis stage to effect alignment.

Liu, Duncan↗

Models of the Cartwheel ring galaxy: Spokes and starbursts

Recent observations of this famous ring galaxy, including optical and near-infrared CCD surface photometry, and VLA radio continuum and 21 cm line mapping (Higdon 1992b, in prep.), have inspired a renewed modeling effort. Toomre's (1978, in The Large-scale Structure of the Universe, eds. Longair and Einasto) series of restricted three-body simulations demonstrated how the multiple rings could be produced in a nearly head-on galaxy collision. New models with a halo-dominated potential based on the 21 cm rotation curve are able to reproduce such details as the spacing between rings, ring widths, offset of the nucleus, and several kinematical features, thus providing strong support for the collisional theory. The new observations have shown there are little or no old stars in Cartwheel; it may consist almost entirely of gas and stars produced as a result of compression in the ring wave. To model this process Smooth Particle Hydrodynamics (SPH) simulations of the Cartwheel disk have been performed. Fixed gravitational potentials were used to represent the Cartwheel and a roughly 30 percent mass collision partner. The interaction dynamics was treated as in the usual restricted three-body approximation, and the effects of local self-gravity between disk particles were calculated. We are particularly interested in testing the theory that enhanced star formation in waves is the result of gravitational instability in the compressed region (see e.g. Kennicutt 1989, ApJ 344, 685). The gas surface density in a number of simulations was initialized to a value slightly below the threshold for local gravitational instability throughout most of the disk. The first ring wave produces relatively modest compressions (a factor of order a few), triggering instability in a narrow range of wavelengths. Self-gravity in the disk is calculated over a comparable range of scales. Simulations were run with isothermal, adiabatic, and adiabatic with radiative cooling characterized by a relatively short timescale. The isothermal approximation is good except in the vicinity of the strong second (inner) ring, and several snapshots from one case are shown in the figure below. Flocculent spiral segments are present before the collision, and these are compressed into dense knots in the ring wave. These knots are likely to be sites of vigorous star formation. In the strong rarefaction behind the outer ring most of the knots are radially stretched and sheared, giving rise to spoke-like features. A few dense knots are evidently very tightly bound, because they retain their coherence and are stretched relatively little through the rarefaction. This is in accord with evidence for continuing star formation in some spokes (Marcum, Appleton and Higdon 1992). The number and spacing of spokes is a direct function of the scale of the gravitational instability in the disk. Thus, the gravitational instability theory, together with the hypothesis that massive stars are only formed in dense knots of gas, can account for most of the distinct morphology of the Cartwheel.

Struck-Marcell, Curtis↗