Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cold”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Cold-cap structure in a slurry-fed electric melter

We report as glass batch is charged into an electric melter, a cold cap forms on the glass melt surface. Heat transfer to the cold cap from the molten glass below and the melter atmosphere above determines the melting rate. A mathematical model of the cold cap and the experimental kinetic data of the feed-to-glass conversion that were collected for several simulated low-activity and high-level waste melter feeds allowed us to develop relationships between the internal structure of the cold cap, its properties, its thickness, and the internal heat transfer. This contribution shows the distribution of major crystalline phases and the cumulative evolution of gases within the cold cap. It also examines the temperature, conversion degree, and heating rate the melter feed is experiencing during the passage through the cold cap and their effects on the cold-cap bottom temperature and morphology, which are important for the computational fluid dynamics simulations of melters.

36 MATERIALS SCIENCE↗

Cold acclimation threshold induction temperatures of switchgrass ecotypes grown under a long and short photoperiod

Abstract Plants can cold acclimate to enhance their freezing tolerance by sensing declining temperature and photoperiod cues. However, the factors influencing genotypic variation in the induction of cold acclimation are poorly understood among perennial grasses. We hypothesized that the more northern upland switchgrass ( Panicum virgatum L.) ecotype develops a higher degree of freezing tolerance by initiating cold acclimation at higher temperatures as compared with the coastal and southern lowland ecotypes. First, we determined the optimal method for assessing freezing tolerance and the length of exposure to 8/4°C required to induce the maximum level of freezing tolerance in the most northern upland and most southern lowland genotypes. We characterized the maximum freezing tolerance of eight uplands, three coastal and five lowland genotypes grown for 21 days at 8/4°C and a 10 or 16 h photoperiod. Next, we identified the temperature required to induce cold acclimation by exposing the 16 genotypes for 7 days at 20–6°C constant temperatures under a 10 or 16 h photoperiod. Cold acclimation initiated at temperatures 5 and 7°C higher in upland than in coastal and lowland genotypes. Among upland genotypes the shorter photoperiod induced cold acclimation at a 1°C higher temperature. Genotypes originating from a more northern latitude initiate cold acclimation at higher temperatures and develop higher maximum freezing tolerances. An earlier response to declining temperatures may provide the upland ecotype with additional time to prepare for winter and provide an advantage when plants are subjected to the rapid changes in fall temperature associated with injurious frosts.

60 APPLIED LIFE SCIENCES↗

Carbide Particle Redistribution in U-10Mo Alloy during Hot and Cold Rolling Processes: Synthetic Microstructure-Based Finite-Element Approach

The influence of initial carbide particle distribution features on particle fracture and the evolution of stringer distribution within an alloy of uranium with 10 weight percent molybdenum during cold rolling was investigated in this study. This work will provide guidance to casting optimization work and identify actionable process changes to eliminate the surface features directly attributed to carbides. In a previous study, various synthetic microstructure-based finite-element (FE) models were generated with consideration of different parameters (i.e., particle shape, particle volume fraction, and particle distribution), and used to examine the effects of hot rolling on the microstructure evolution. In this study, microstructures after ~80% hot rolling were used as the initial microstructures for the subsequent cold rolling simulation. Plane-strain compression loading was employed in the FE models to simulate cold rolling with reductions from ~80% to ~94%. Stringer analyses with the consideration of particle fracture were then performed with the simulated cold rolling results. The results of void evolution analyses show that microstructures with elliptical particles incorporate a much larger (almost double) void volume fraction than those with circular particles, indicating that the elliptical particles are fractured more easily than the circular ones. The results from the fracture mode analyses show that, under the adopted simple compression loading assumption, almost all the particles (i.e., >99%) were fractured by tensile separation. The results of stringer analyses show that, during cold rolling, the stringer volume fractions increase substantially due to the particle fracture, especially for the microstructures with the elliptical particles, and that the stringer volume fractions from stringers comprising many particles tend to increase faster. The maximum stringer lengths for the microstructures with circular particles tend to remain constant or decrease during cold rolling, whereas those for elliptical particles tend to slightly increase after a slight decrease. The number of particles at the surface increases very rapidly due to particle fracture during cold rolling.

36 MATERIALS SCIENCE↗

CHL1 2K COLD BOX REPLACEMENT

There is growing evidence showing that the cold compressors in the Modified Sub-atmospheric Cold Box (SC1/SCM) of the JLab Central Helium Liquefier (CHL) are approaching the end of their life. Their replacement parts are no longer available due to obsolescence, thus placing the Physics program at serious risk. A new sub-atmospheric cold box (SC1R), which hosts five technologically superior, water-cooled cold compressors and a similar 4K-2K refrigeration recovery heat exchanger, was funded in July 2017, to replace the existing 2K cold box. The design of the new 2K cold box and the external support system have been completed allowing the project to enter the fabrication and assembly phase, which will be completed here at JLab. We present the design, fabrication, installation and commissioning schedule of the new 2K cold box.

Yang, Shirley↗

Cold Trap Replacement Project Report

This report documents the replacement of the Mechanisms Engineering Test Loop (METL) cold trap. The work involved preparation of the facility to replace the cold trap, removal of the existing welded cold trap from the sodium purification circuit, installation of a new replacement cold trap, completion of associated welds and examinations, restoration of instrumentation and heaters, and controlled return of the cold trap circuit to service. The replacement represented a significant maintenance evolution because the cold trap is an integral welded component of the sodium system. As a result, the work required coordinated control of sodium chemistry, deliberate formation of freeze plugs, inert gas management, precision cutting and welding, and a staged reheating and refill sequence. The activity was executed using procedural controls intended to protect personnel, preserve system cleanliness, and maintain the integrity of the sodium boundary throughout the work. This report provides a narrative summary of the milestone, including the purpose of the work, the pre-job system condition, the major field activities performed, observations made during execution, and the resulting post-work condition of the METL cold trap circuit.

42 ENGINEERING↗

Abscisic Acid Mediates Grafting-Induced Cold Tolerance of Watermelon via Interaction With Melatonin and Methyl Jasmonate

Grafting is widely used to increase plant defense responses to various stresses. Grafting-induced cold tolerance is associated with the increase of the antioxidant potential of plants; however, the underlying mechanisms remain unclear. Here, we found that pumpkin rootstocks promote antioxidant enzyme activities and alleviate cold-induced oxidative damage, accompanied by increased abscisic acid (ABA), melatonin, and methyl jasmonate (MeJA) levels in leaves. Increased ABA accumulation in leaves was attributed partly to the increased ABA levels in rootstocks. ABA induced antioxidant enzymes activities and the accumulation of melatonin and MeJA, while inhibition of ABA synthesis blocked the rootstock-induced antioxidant activity and the accumulation of melatonin and MeJA under cold stress. Melatonin and MeJA application also enhanced ABA accumulation in leaves after cold exposure, whereas inhibition of melatonin or MeJA synthesis attenuated the rootstock-induced increase of ABA. Moreover, melatonin and MeJA application alleviated cold-induced oxidative stress, but inhibition of melatonin or MeJA synthesis lowered the rootstock- or ABA-induced antioxidant potential and tolerance to cold. These findings indicate that ABA plays an important role in the grafting-induced cold tolerance by promoting the accumulation of melatonin and MeJA, which in turn, promote ABA accumulation, forming a positive feedback loop.

Guo, Yanliang↗

DISTRIBUTION OF COLD (≲300 K) ATOMIC GAS IN GALAXIES: RESULTS FROM THE GBT H i ABSORPTION SURVEY PROBING THE INNER HALOS ( ρ < 20 kpc) OF LOW- z GALAXIES

We present the Green Bank Telescope absorption survey of cold atomic hydrogen (≲300 K) in the inner halo of low-redshift galaxies. The survey aims to characterize the cold gas distribution and to address where the condensation—the process where ionized gas accreted by galaxies condenses into cold gas within the disks of galaxies—occurs. Our sample consists of 16 galaxy–quasar pairs with impact parameters of ≤20 kpc. We detected an H i absorber associated with J0958+3222 (NGC 3067) and H i emission from six galaxies. We also found two Ca ii absorption systems in the archival SDSS data associated with galaxies J0958+3222 and J1228+3706. Our detection rate of H i absorbers with optical depths of ≥0.06 is ∼7%. We also find that the cold H i phase (≲300 K) is 44(±18)% of the total atomic gas in the sightline probing J0958+3222. We find no correlation between the peak optical depth and impact parameter or stellar and H i radii normalized impact parameters, ρ / R {sub 90} and ρ / R {sub H} {sub i}. We conclude that the process of condensation of inflowing gas into cold (≲300 K) H i occurs at the ρ ≪ 20 kpc. However, the warmer phase of neutral gas ( T ∼ 1000 K) can exist out to much larger distances, as seen in emission maps. Therefore, the process of condensation of warm to cold H i is likely occurring in stages from ionized to warm H i in the inner halo and then to cold H i very close to the galaxy disk.

79 ASTRONOMY AND ASTROPHYSICS↗

The lower hybrid density drift instability with cold plasma

The linear Vlasov dispersion relation for the lower hybrid density drift instability is studied in a four component (hot electrons and protons, cold electrons and protons) plasma. The introduction of a cold ion population monotonically reduces the maximum growth rate of the instability. Reduction of the ratio of temperatures of the cold and hot plasmas reduces both the real frequency and the growth rate of the instability. Near a ratio of the cold and hot plasma temperatures of 0.01 a higher frequency branch of this instability emerges and for a fixed ratio of cold and hot electron density exhibits an increasing maximum growth rate as the ratio of the cold and hot plasma temperatures decreases further. The ratio of the cold and hot plasma temperatures for the ions is the crucial parameter and deserves detailed magnetospheric studies.

Gary, S. P.↗

Analysis of cold worked holes for structural life extension

Cold working holes for improved fatigue life of fastener holes are widely used on aircraft. This paper presents methods used by the authors to determine the percent of cold working to be applied and to analyze fatigue crack growth of cold worked fastener holes. An elastic, perfectly-plastic analysis of a thick-walled tube is used to determine the stress field during the cold working process and the residual stress field after the process is completed. The results of the elastic/plastic analysis are used to determine the amount of cold working to apply to a hole. The residual stress field is then used to perform damage tolerance analysis of a crack growing out of a cold worked fastener hole. This analysis method is easily implemented in existing crack growth computer codes so that the cold worked holes can be used to extend the structural life of aircraft. Analytical results are compared to test data where appropriate.

Wieland, David H.↗

Compact, Two-Sided Structural Cold Plate Configuration

In two-sided structural cold plates, typically there is a structural member, such as a honeycomb panel, that provides the structural strength for the cold plates that cool equipment. The cold plates are located on either side of the structural member and thus need to have the cooling fluid supplied to them. One method of accomplishing this is to route the inlet and outlet tubing to both sides of the structural member. Another method might be to supply the inlet to one side and the outlet to the other. With the latter method, an external feature such as a hose, tube, or manifold must be incorporated to pass the fluid from one side of the structural member to the other. Although this is a more compact design than the first option, since it eliminates the need for a dedicated supply and return line to each side of the structural member, it still poses problems, as these external features can be easily damaged and are now new areas for potential fluid leakage. This invention eliminates the need for an external feature and instead incorporates the feature internally to the structural member. This is accomplished by utilizing a threaded insert that not only connects the cold plate to the structural member, but also allows the cooling fluid to flow through it into the structural member, and then to the cold plate on the opposite side. The insert also employs a cap that acts as a cover to seal the open area needed to install the insert. There are multiple options for location of o-ring style seals, as well as the option to use adhesive for redundant sealing. Another option is to weld the cap to the cold plate after its installation, thus making it an integral part of the structural member. This new configuration allows the fluid to pass from one cold plate to the other without any exposed external features.

Zaffetti, Mark↗

Impact of a Cold Pool Parameterization on the Diurnal Cycle and Intraseasonal Variability in the GEOS AGCM

A gradual transition from shallow to deep convection may be important both to the continental diurnal cycle of precipitation and to the tropical Madden-Julian Oscillation. However, many existing convection parameterizations transition too readily, with corresponding diurnal and intraseasonal biases. High entrainment rates can be used to delay deep convection, but typically produce mean state biases; this is the "entrainment dilemma." Cold pools and sub-grid organization offer a potential solution to this dilemma, and recent work shows parameterized cold pools can effectively modulate deep convection, with improvements to the diurnal cycle and intraseasonal variability. Here we investigate the effects of a simple prognostic cold pool scheme coupled to the Grell-Freitas convection parameterization, in a set of global simulations with the NASA GEOS model. Air detrained from parameterized downdrafts is maintained in vertically resolved cold pools, which evolve with simplified dynamics. We test several options for cold pool feedbacks on convection, including modifications to deep convective entrainment rates, convective source air properties, and thermodynamic profiles, based on the level of cold pool activity. Cold pool impacts on the diurnal cycle are evaluated against TRMM, and moisture and moist static energy budgets are used to understand changes in tropical intraseasonal variability. Preliminary results show delays in the diurnal cycle of precipitation.

Arnold, Nathan↗

NUCLEAR WASTE VITRIFICATION EFFICIENCY COLD CAP REACTIONS

The cost and schedule of nuclear waste treatment and immobilization are greatly affected by the rate of glass production. Various factors influence the performance of a waste-glass melter. One of the most significant, and also one of the least understood, is the process of batch melting. Studies are being conducted to gain fundamental understanding of the batch reactions, particularly those that influence the rate of melting, and models are being developed to link batch makeup and melter operation to the melting rate. Batch melting takes place within the cold cap, i.e., a batch layer floating on the surface of molten glass. The conversion of batch to glass consists of various chemical reactions, phase transitions, and diffusion-controlled processes. These include water evaporation (slurry feed contains as high as 60% water), gas evolution, the melting of salts, the formation of borate melt, reactions of borate melt with molten salts and with amorphous oxides (Fe{sub 2}O{sub 3} and Al{sub 2}O{sub 3}), the formation of intermediate crystalline phases, the formation of a continuous glass-forming melt, the growth and collapse of primary foam, and the dissolution of residual solids. To this list we also need to add the formation of secondary foam that originates from molten glass but accumulates on the bottom of the cold cap. This study presents relevant data obtained for a high-level-waste melter feed and introduces a one-dimensional (1D) mathematical model of the cold cap as a step toward an advanced three-dimensional (3D) version for a complete model of the waste glass melter. The 1D model describes the batch-to-glass conversion within the cold cap as it progresses in a vertical direction. With constitutive equations and key parameters based on measured data, and simplified boundary conditions on the cold-cap interfaces with the glass melt and the plenum space of the melter, the model provides sensitivity analysis of the response of the cold cap to the batch makeup and melter conditions. The model demonstrates that batch foaming has a decisive influence on the rate of melting. Understanding the dynamics of the foam layer at the bottom of the cold cap and the heat transfer through it appears crucial for a reliable prediction of the rate of melting as a function of the melter-feed makeup and melter operation parameters. Although the study is focused on a batch for waste vitrification, the authors expect that the outcome will also be relevant for commercial glass melting.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

System and method for crystalline sheet growth using a cold block and gas jet

A crystallizer for growing a crystalline sheet from a melt may include a cold block having a cold block surface that faces an exposed surface of the melt, the cold block configured to generate a cold block temperature at the cold block surface that is lower than a melt temperature of the melt at the exposed surface. The system may also include a nozzle disposed within the cold block and configured to deliver a gas jet to the exposed surface, wherein the gas jet and the cold block are interoperative to generate a process zone that removes heat from the exposed surface at a first heat removal rate that is greater than a second heat removal rate from the exposed surface in outer regions outside of the process zone.

36 MATERIALS SCIENCE↗

Updated weather model captures subtleties of cold-air pool events

Imagine cold air building up inside a valley or other topographic basin, like a cold swimming pool in the atmosphere. Known in meteorology as cold-air pools, or simply cold pools, these events affect wind plant power production in two key ways. Because they are associated with stagnant air and low winds near the ground, cold pools can severely limit wind energy output over periods of hours to days. Then, when cold pools dissolve, known as cold pool “erosion,” increased wind speeds allow wind power production to recover.

Energy↗

The Cold and Dark Process at the Savannah River Site

The deactivation and decommissioning (D and D) of a facility exposes D and D workers to numerous hazards. One of the more serious hazards is coming into contact to hazardous energy sources (e.g. electrical, pressurized steam). At the Savannah River Site (SRS) a formal process for identifying and eliminating sources of hazardous energy was developed and is called 'Cold and Dark'. Several 'near miss' events involving cutting of energized conductors during D and D work in buildings thought to be isolated identified the need to have a formal process to identify and isolate these potentially hazardous systems. This process was developed using lessons learned from D and D activities at the Rocky Flats Environmental Technology Site (Rocky Flats) in Colorado. The Cold and Dark process defines an isolation boundary (usually a building perimeter) and then systematically identifies all of the penetrations through this boundary. All penetrations that involve hazardous energy sources are then physically air-gapped. The final product is a documented declaration of isolation performed by a team involving operations, engineering, and project management. Once the Cold and Dark declaration is made for a building work can proceed without the usual controls used in an operational facility (e.g. lockout/tag-out, arc flash PPE). It is important to note that the Cold and Dark process does not remove all hazards from a facility. Work planning and controls still need to address hazards that can be present from such things as chemicals, radiological contamination, residual liquids, etc., as well as standard industrial hazards. Savannah River Site experienced 6 electrical events prior to declaring a facility 'cold and dark' and has had zero electrical events after 'cold and dark' declaration (263 facilities to date). The formal Cold and Dark process developed at SRS has eliminated D and D worker exposures to hazardous energy sources. Since the implementation of the process there have been no incidents involving energized conductors or pressurized liquids/gases. During this time SRS has demolished over 200 facilities. The ability to perform intrusive D and D activities without the normal controls such as lock outs results in shorter schedule durations and lower overall costs for a facility D and D.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessment of Cold Spraying Mild-Steel Powder onto Mild-Steel Substrate for Development of Waste Tank Repair System - 20515

Infrastructure for nuclear waste storage and processing (e.g., waste tanks, transfer pipelines, evaporators) at the U.S. Department of Energy (DOE) Hanford Site has been in service well beyond its original design life. Past corrosion control methods at Hanford for waste tanks have not been fully successful, as evidenced by leaks forming in tank AY-102, the first double-shell tank (DST) constructed, and significant degradation detected in the primary tanks of AP-102 and AY-101. Failure of infrastructure components can pose a significant risk to the environment, worker safety, and project schedules. Therefore, remotely deployable methods for repairing and extending the service life of the existing tank waste infrastructure are needed. Cold spray has been identified as a potential technique for performing in situ repairs and material buildup for life extension of waste storage and processing infrastructure. Cold-spray repair methods and technology are well-established and are used extensively by industry and the military for making repairs using dissimilar materials. Pacific Northwest National Laboratory is evaluating the process of making repairs using mild-steel powder applied to a mild-steel substrate to minimize the galvanic corrosion potential. This paper presents the initial results for a feasibility ('go/no-go') assessment as to whether low-density deposits with sound metallurgic bonds, to build-back steel plate material, can be achieved using existing commercial cold-spray equipment. An assessment of steel-on-steel deposit is necessary to determine if cold spray is a viable candidate for DST carbon steel plate restoration/repair and thus DST service life extension. Powder properties and preparation requirements have been investigated and operating conditions and parameters for depositing a cold-spray buildup of mild steel on a mild-steel substrate have been determined. Soundness of metallurgic bonding as a function of the operating parameters exercised and results from applying cold spray to lay a deposit over simulated small-diameter flaws in 1/2-inch mild-steel plate are presented. Application of in situ cold-spray repair to the DOE complex has the potential to reduce cost and schedule impacts associated with component failures and the need to procure and construct replacement infrastructure. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Global Seasonal Relationship Between Satellite-Observed Cold Pools and Rainfall

Convective cold pools are important modulators of the onset and evolution of deep convection in the tropics. This work leverages a dataset derived from the Advanced Scatterometer (ASCAT) satellite instrument by Garg et al. (2020) to quantify seasonal variations in cold pool activity and their relationship to deep convection across tropical ocean basins. The dataset identifies gradient features (GFs) in the surface wind field, which have been shown to serve as reliable proxies for the boundaries of atmospheric cold pools. We examine the relationship between GFs and climatologies of precipitation, column relative humidity (CRH), and bulk vertical wind shear. We also collocate GFs with precipitation and CRH. High GF frequency, precipitation, and CRH coincide in many regions of the tropics, consistent with our understanding of the physical connections between precipitation and cold pool generation. On the other hand, climatological bulk wind shear is often low in convective regions, and there is a weak inverse correlation between GF frequency and bulk wind shear, while our prior expectation might have been that shear promotes cold pool formation. Compared to GF frequency, GF size shows a weaker relationship with the convective environment, with some of the largest GF sizes occurring at lower CRH values for a given rainfall rate. In a few exceptional regions and seasons, such as the Indian Ocean in northern hemisphere summer, the region of greatest precipitation does not coincide with the region of greatest GF frequency. These cases also have very high seasonal mean CRH, suggesting that in these regions cold pool formation is suppressed by reduced evaporation of precipitation.

Convective cold pools↗

Effect of Heat Treatment and Combination of Cold Rolling and Heat Treatment on Microstructure and Mechanical Properties of Titanium Alloy Ti6Al2V2Zr1.5Mo

The heat treatment and cold rolling combinations have been carried out on titanium alloy Ti6Al2V2Zr1.5Mo, and microstructure evolution and mechanical behavior have been studied. Solution treatment below the β-transus temperature, followed by air cooling, resulted in higher microhardness/strength as compared to the same with water quenching. A sudden drop in microhardness/strength is observed in sample solution heat-treated above β-transus temperature followed by air cooling. The former is attributed to the additional presence of fine secondary α-phase formed by dynamic aging during air cooling as compared to water-quenched samples which did not have fine secondary α-phase. Solution treatment above β-transus temperature resulted in Widmanstatten microstructure with no significant fine secondary α in air-cooled samples. Among the studied conditions of cold rolling (CR), gain in strength of the alloy from annealed condition is significant with first 15% reduction and thereafter it is marginal for 30% reduction. Initiation of cracks at the edges has been observed in 30% CR. The microstructure of cold-rolled samples confirms the fragmentation of α-plates with the presence of high dislocation density. Heat treatment of cold-rolled samples resulted in significant reduction in strength from the as-cold-rolled conditions. The marginally lower strength than the as-received (annealed) or heat-treated alloy samples is due to the recrystallization in CR samples and the formation of Widmanstatten microstructure in air-cooled samples. The alloy does not have fine secondary α or regions with large dislocation density in this condition. The microstructure in the samples heat-treated (with air cooling) below as well as above β-transus temperature (after CR) is similar to air-cooled samples (without prior CR) with heat treatment above β-transus temperature. This indicates the reduction in recrystallization temperature with cold working, which is substantiated with the reduction in strength as well.

36 MATERIALS SCIENCE↗