Search NASA⌕ Search

SEARCH · Search NASA

Results for “Commercial Transport”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Bipolar Membranes Electrodialysis for Water Purification and Resource Recovery

Reverse osmosis concentrate (ROC) from inland brackish water desalination and wastewater recycling presents moderate salinity, posing significant challenges for treatment and disposal. Existing treatment technologies predominantly rely on energy-intensive thermal methods, large-area evaporation strategies, or deep-well disposal, which often result in the loss of water value. Electrified membrane brine treatment offers a promising alternative by utilizing renewable energy sources, enabling complete water recycling. This work proposes the development of next-generation bipolar membrane electrodialysis (BMED) systems capable of desalinating brine while simultaneously recovering valuable resources. However, several critical challenges remain in the areas of membrane engineering for BMED. These include: 1) decreased current efficiency during desalination due to the low conductivity of feed chambers, 2) fouling and scaling from multivalent ions and contaminants in the feed, and 3) the retention and carryover of ROC contaminants, including PFAS compounds. Our research focuses on the development of novel anion exchange membranes (AEMs) and cation exchange membranes (CEMs) based on synthesized multiblock copolymers. We investigate the effects of block length, ion exchange capacity (IEC), and polymer backbone structure on cation and anion transport (e.g., Na+, Cl-, OH-, H+) for both our synthesized membranes and commercial membranes. Fundamental properties of these membranes, such as water uptake, IEC, and ionic conductivity, are also evaluated to optimize performance for BMED applications.

08 HYDROGEN↗

Long-term durability test of highly efficient membrane electrode assemblies for anion exchange membrane seawater electrolyzers

Direct seawater electrolysis faces fundamental electrochemical challenges, such as suppression of chlorine adsorption and/or evolution reactions that poison the current state-of-the-art anode catalysts and accelerate the degradation of the anion exchange membrane (AEM). The technically favored solution path for addressing these issues includes development of novel selective catalysts and implementation of limited operating conditions. Therefore, development of highly active, selective, cost-effective, and stable seawater-splitting catalysts is required for a successful commercialization of the AEM water electrolyzers (AEMWEs). In this work, we report for the first-time an extended operation for over 1000 h of advanced AEMWEs, operating directly with seawater. To fabricate the membrane electrode assemblies (MEAs), catalyst coated electrodes (CCEs) are assembled with Sustainion® X37-50 grade T anion exchange membranes. The anode CCEs are fabricated by spraying an ink prepared from nanostructured NiFe-layered double hydroxide (LDH) catalyst that are synthesized by the solvothermal method and deposited directly onto platinized titanium porous transport layers (PTLs). The cathode CCEs are prepared by spraying an ink prepared from commercial Renay-Nickel catalyst onto a nickel fiber felt. As prepared AEM electrolyzer cells operated with seawater and demonstrated better than previously reported in the literature performance of over 1000 h of operation at a constant current density of 300 mA cm –2 .

25 ENERGY STORAGE↗

Potential Chemical Impacts of Subsurface CO 2 : An Integrated Experimental and Numerical Assessment for a Case Study of the Ogallala Aquifer

Leakage from geologic CO 2 sequestration (GCS) reservoirs to overlying underground sources of drinking water (USDW) is a tangible risk. This study is an integrated assessment that combines column experiments and reactive transport simulations of sediments sampled from the Ogallala aquifer above an active commercial-scale GCS site (the Farnsworth Unit in northern Texas). Experimental and simulation results suggest that carbonate mineral (calcite and dolomite) dissolution is the most significant reaction following CO 2 intrusion, and is also the dominant source of trace metal release. Cation exchange is another key mechanism controlling trace metal release by cation interference. Most of the trace metals, including Ba, Sr, As, Pb, and Zn, show a short-term release and quickly drop to the baseline values, suggesting low risk to the overlying USDW quality. Other trace metals, such as Mn and U, exhibit a tangible increase of their concentrations in the beginning, and drop to a higher level compared to the baseline, which may become a potential concern of long-term USDW quality change with CO2introduction. This study provides a comprehensive example of combining laboratory experiments and simulations for assessment of CO 2 -sediment interactions with combined release mechanisms in shallow groundwater aquifers. Data presented here provides useful insights for quantitative risk assessment and effective public education regarding CO 2 geological sequestration, and trace metal reactive transport studies in shallow groundwater aquifers.

54 ENVIRONMENTAL SCIENCES↗

3D Carbon Coating Enabled High‐capacity and Stable Micro‐sized Silicon Suboxide‐graphite Blended Anodes for Practical Lithium‐ion Batteries

Abstract Silicon oxide (SiO x ) is a promising anode candidate of lithium‐ion batteries (LIBs) owing to its extremely high specific capacity. However, the low initial Coulombic efficiency (ICE) and rapid capacity degradation of SiO x , triggered by the enormous volume variation upon repeated (de)lithiation, gravely hinder its practical use. Herein, two mass‐produced micro‐sized SiO x @C composites with obviously different morphologies for commercial LIBs are reported. Particularly, the SiO x ‐graphite blended anode (SiO x @3D‐G‐Gr) based on SiO x wrapped by three‐dimensional (3D) carbon layers (SiO x @3D‐G) exhibits a capacity of 519 mAh g −1 , an ICE of 90.0 % and a capacity retention of 83.4 % at 0.2 C over 100 cycles. which is far exceeding its counterpart SiO x @C‐H‐Gr (65.7 %). The obtained impressive properties of SiO x @3D‐G originate from the critical contribution of 3D carbon layers, which serves as the effective stress buffer and protective layer as well as the strong networks for electron/Li + transport. Accordingly, the full‐cell based on SiO x @3D‐G‐Gr anode and commercial LiCoO 2 cathode delivers a capacity of 803 mAh and an excellent capacity retention of 95.6 % (616 mAh, 96.6 % for graphite, respectively) at 1 C over 100 cycles with a stabilized CE of nearly 100 %. The micro‐sized SiO x @3D‐G showing a promising prospect in the commercial‐grade anodes in LIBs.

Electrochemistry↗

Highly Efficient Magnetocaloric Natural Gas Liquefaction (Final Report)

Over the twelve-month project the following achievements were accomplished: • Liquefication of methane as primary component of natural gas was accomplished with a magnetocaloric liquefier (MCL) prototype. This was the first time an MCL was used to liquefy methane. • Improved MCL designs were completed. • Cooling to 135 K from room temperature was achieved for the first time in a single MCL stage with dual, reciprocating four-layer regenerators. • Techno-economic analysis for a multi-stage 5 tonne/day magnetocaloric liquefier was completed. The detailed thermodynamic analysis of this MCL design showed a figure of merit (FOM) of 0.6 was achievable. This is a ~2x improvement over current state of the art. • Cost of an efficient 5 tonne/day LNG multi-stage liquefier was projected to be ~$\$$3.1 MM for the 5 tonne/day MCL with achievable design assumptions. • Market study of U.S. merchant LNG demand by energy sector was completed showing that at beginning of 2019, total use was ~2.5 million gallons/day primarily in three sectors that was filled by ~20 small companies in the merchant LNG supply business producing ~2.3 million gpd. These data exclude LNG produced at dedicated peak shaving and large export plants. • Business case for MCL technology based on LNG market study was completed showing the high FOM feature of MCL reduces cost of plant power, and lower capital cost reduces debt repayment and plant depreciation operating expenses. However, today’s demand for U.S. merchant LNG in most sectors is satisfied with conventional technology. Further, with today’s extremely low natural gas (NG) feedstock costs (e.g., ~$\$$1.8/MMBtu), the cost of fuel for NG gensets and for LNG feedstock is already very low. Therefore, possible new merchant LNG liquefier plant developers anticipating demand growth in the transportation, industrial, and electricity generation sectors do not obtain sufficient cost benefits to adopt new, commercially unproven MCL technology. • Other market factors such as remoteness from existing NG pipelines, or unfilled or unsatisfied applications such as boil-off gas re-liquefaction in LNG vessels, or policy factors such as some form of emissions-related fees may make lower capital costs and higher FOM of MCL technology attractive for new small-scale (~50 tonne/day) LNG plants. Two potentially attractive niche markets for MCL technology were identified: i) re-liquefaction of boil-off gas from large LNG transport vessels where severe transport conditions are problematic for conventional technology; and ii) providing LNG in distributed-scale plants that eliminate road transport costs to meet diverse, smaller-scale, distributed LNG bunkering fuel demands. By eliminating significant cryogenic tanker delivery costs and create an attractive cost-savings benefit with small-scale MCL plants.

03 NATURAL GAS↗

Use of Hydrogel Electrolyte in Zn-MnO2 Rechargeable Batteries: Characterization of Safety, Performance, and Cu2+ Ion Diffusion

Achieving commercially acceptable Zn-MnO2 rechargeable batteries depends on the reversibility of active zinc and manganese materials, and avoiding side reactions during the second electron reaction of MnO2. Typically, liquid electrolytes such as potassium hydroxide (KOH) are used for Zn-MnO2 rechargeable batteries. However, it is known that using liquid electrolytes causes the formation of electrochemically inactive materials, such as precipitation Mn3O4 or ZnMn2O4 resulting from the uncontrollable reaction of Mn3+ dissolved species with zincate ions. In this paper, hydrogel electrolytes are tested for MnO2 electrodes undergoing two-electron cycling. Improved cell safety is achieved because the hydrogel electrolyte is non-spillable, according to standards from the US Department of Transportation (DOT). The cycling of “half cells” with advanced-formulation MnO2 cathodes paired with commercial NiOOH electrodes is tested with hydrogel and a normal electrolyte, to detect changes to the zincate crossover and reaction from anode to cathode. These half cells achieved ≥700 cycles with 99% coulombic efficiency and 63% energy efficiency at C/3 rates based on the second electron capacity of MnO2. Other cycling tests with “full cells” of Zn anodes with the same MnO2 cathodes achieved ~300 cycles until reaching 50% capacity fade, a comparable performance to cells using liquid electrolyte. Electrodes dissected after cycling showed that the liquid electrolyte allowed Cu ions to migrate more than the hydrogel electrolyte. However, measurements of the Cu diffusion coefficient showed no difference between liquid and gel electrolytes; thus, it was hypothesized that the gel electrolytes reduced the occurrence of Cu short circuits by either (a) reducing electrode physical contact to the separator or (b) reducing electro-convective electrolyte transport that may be as important as diffusive transport.

25 ENERGY STORAGE↗

Differences in water and vapor transport through angstrom-scale pores in atomically thin membranes

Abstract The transport of water through nanoscale capillaries/pores plays a prominent role in biology, ionic/molecular separations, water treatment and protective applications. However, the mechanisms of water and vapor transport through nanoscale confinements remain to be fully understood. Angstrom-scale pores (~2.8–6.6 Å) introduced into the atomically thin graphene lattice represent ideal model systems to probe water transport at the molecular-length scale with short pores (aspect ratio ~1–1.9) i.e., pore diameters approach the pore length (~3.4 Å) at the theoretical limit of material thickness. Here, we report on orders of magnitude differences (~80×) between transport of water vapor (~44.2–52.4 g m −2 day −1 Pa −1 ) and liquid water (0.6–2 g m −2 day −1 Pa −1 ) through nanopores (~2.8–6.6 Å in diameter) in monolayer graphene and rationalize this difference via a flow resistance model in which liquid water permeation occurs near the continuum regime whereas water vapor transport occurs in the free molecular flow regime. We demonstrate centimeter-scale atomically thin graphene membranes with up to an order of magnitude higher water vapor transport rate (~5.4–6.1 × 10 4 g m −2 day −1 ) than most commercially available ultra-breathable protective materials while effectively blocking even sub-nanometer (>0.66 nm) model ions/molecules.

36 MATERIALS SCIENCE↗

Bio-inspired multiscale design for perovskite solar cells

Metal halide perovskite semiconductors have attractive light-harvesting and charge-carrier transport properties for photovoltaics. Perovskite solar cells (PSCs) and modules have demonstrated their commercial promise with high power conversion efficiencies, but still face stability challenges. In this Review, we explore how biomaterials offer design inspiration for the development of durable and efficient PSCs at three different scales. At the molecular level, bio-inspired molecular interactions are harnessed towards crystallization control and degradation prevention, which offers an enhancement in long-term maximum-power-point tracking stability. At the microstructural level, self-healing and strength-enhancing strategies, utilizing dynamic bonds and interfacial reinforcement, can help PSCs to recover from physical damage and maintain high performance. At the device level, macroscopic functionalities, such as moth-eye-inspired structures tailored to different layers, can collectively enable antireflection, radiative cooling and self-cleaning to optimize light management, heat dissipation and encapsulation in PSCs. Bio-inspired PSC research can combine improved efficiency and lifetime, with abundant, biocompatible alternatives to conventional stabilizers. Future efforts should focus on screening bioinspired molecules to optimize film crystallization and stability, developing self-healing mechanisms triggered by operational stress, designing cost-efficient biomicrostructures, and integrating multifunctional encapsulation to enhance the efficiency and lifespan of PSCs.

Duan, Tianwei↗

(Invited) Continuum Mathematical Modeling of Water Electrolysis: A Tutorial

Widespread use of hydrogen energy is contingent on the development of reliable and economical sources of hydrogen. Electrolysis from renewably-derived low-carbon electricity is a potentially viable method of hydrogen generation. Prime among the electrolysis technologies are those utilizing ion-conducting polymers (ionomers) including proton-exchange-membrane water electrolyzer (PEMWE). However, these technologies need to exhibit increased efficiency, performance, and durability to become commercially viable. Like most electrochemical devices, PEMWEs involve multiple components (e.g., catalyst, ionomer, transport layers, membrane, plates) and multiple phases, with phenomena occurring across different time and length scales. Furthermore, it is difficult to experimentally probe many of the species and phenomena during operation. Thus, mathematical modeling at the continuum level has been an invaluable aid in exploring, understanding, and optimizing PEMWE cell and components. Furthermore, this is especially true in the highly coupled and complex physics and chemistries that occur with the membrane-electrode assembly (MEA). The physics in a typical volume-averaged non-isothermal model include multiphase transport in porous media, concentrated-solution theory, Ohm's Law, and Butler-Volmer kinetics, and ion, gas, and water transport in the ionomer.

Dizon, Arthur↗

Design, Build, and Initial Testing of a Portable Methane Measurement Platform

The quantification of methane concentrations in air is essential for the quantification of methane emissions, which in turn is necessary to determine absolute emissions and the efficacy of emission mitigation strategies. These are essential if countries are to meet climate goals. Large-scale deployment of methane analyzers across millions of emission sites is prohibitively expensive, and lower-cost instrumentation has been recently developed as an alternative. Currently, it is unclear how cheaper instrumentation will affect measurement resolution or accuracy. To test this, the Wireless Autonomous Transportable Methane Emission Reporting System (WATCH 4 ERS) has been developed, comprising four commercially available sensing technologies: metal oxide (MOx,), Non-dispersion Infrared (NDIR), integrated infrared (INIR), and tunable diode laser absorption spectrometer (TDLAS). WATCHERS is the accumulated knowledge of several long-term methane measurement projects at Colorado State University’s Methane Emission Technology Evaluation Center (METEC), and this study describes the integration of these sensors into a single unit and reports initial instrument response to calibration procedures and controlled release experiments. Specifically, this paper aims to describe the development of the WATCH 4 ERS unit, report initial sensor responses, and describe future research goals. Meanwhile, future work will use data gathered by multiple WATCH 4 ERS units to 1. better understand the cost–benefit balance of methane sensors, and 2. identify how decreasing instrumentation costs could increase deployment coverage and therefore inform large-scale methane monitoring strategies. Both calibration and response experiments indicate the INIR has little practical use for measuring methane concentrations less than 500 ppm. The MOx sensor is shown to have a logarithmic response to methane concentration change between background and 600 ppm but it is strongly suggested that passively sampling MOx sensors cannot respond fast enough to report concentrations that change in a sub-minute time frame. The NDIR sensor reported a linear change to methane concentration between background and 600 ppm, although there was a noticeable lag in reporting changing concentration, especially at higher values, and individual peaks could be observed throughout the experiment even when the plumes were released 5 s apart. The TDLAS sensor reported all changes in concentration but remains prohibitively expensive. Our findings suggest that each sensor technology could be optimized by either operational design or deployment location to quantify methane emissions. The WATCH4ERS units will be deployed in real-world environments to investigate the utility of each in the future.

47 OTHER INSTRUMENTATION↗

Nuclear Safety [Vol. 32, No. 1, January-March 1991]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 1 The Safety Review and Approval Process for Space Nuclear Power Sources, G. L. Bennett; 19 Report on the American Nuclear Society International Topical Meeting: "The Safety, Status, and Future of Non-Commercial Reactors and Irradiation Facilities", E. G. Silver; 35 Book Review: Fission Product Transport Processes in Reactor Accidents, Proceedings to the International Centre tor Heat and Mass Processes T. S. Kress; 38 Fast Reactor Technology in the 1990s: A Summary of the 1990 International Fast Reactor Safety Meeting, A. E. Levin; ACCIDENT ANALYSIS: 56 Effects of Chemical Phenomena on LWR Severe Accident Fission Product Behavior, A. P. Malinauskas and T. S. Kress; CONTROL AND INSTRUMENTATION: 65 Technical Note: Safety Parameter Display Systems—10 Years Later, R. J. Eckenrode; 68 Potential Application of Neural Networks to the Operation of Nuclear Power Plants, R. E. Uhrig; DESIGN FEATURES: 80 Twenty-First DOE/NRC Nuclear Air-Cleaning Conference, R. R. Bellamy, D. W. Moeller, and M. W. First; 91 Impact of an Apparent Radiation Embrittlement Rate on the Life Expectancy of PWR Vessel Supports, R. D. Cheverton, G. C. Robinson, W. E. Pennell, and R. K. Nanstad; ENVIRONMENTAL EFFECTS: 103 Technical Note: The Impact of Offsite Factors on the Safety Performance of Small Nuclear Power Plants, Yu. D. Baranaev and A. N. Viktorov; WASTE AND SPENT FUEL MANAGEMENT: 109 Activities Related to Waste Management, Compiled by E. G. Silver; OPERATING EXPERIENCES: 118 Reactor Shutdown Experience, Compiled by J. W. Cletcher; 121 Selected Safety-Related Events, Compiled by G. A. Murphy; 123 Operating U.S. Power Reactors, Compiled by E. G. Silver; RECENT DEVELOPMENTS: 140 General Administrative Activities, Compiled by E. G. Silver; 150 Reports, Standards, and Safety Guides, D. S. Queener; 155 Status of Power-Reactor Licensing Activities, Compiled by E. G. Silver; 157 Proposed Rule Changes as of Sept. 30, 1990; ANNOUNCEMENTS: 79 MIT Offers Summer Program on Nuclear Power Reactor Safety; 108 Harvard School of Public Health Offers Several Short Courses; 139 Short Course and Workshop on Nuclear Criticality Safety at University of New Mexico; 160 SCK/CEN Announces Training Course on Emergency Planning and Response; 161 The Authors; 164 Indexes to Nuclear Safety, Volume 31

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of a Techno-Economic Analysis Framework for a Solar Thermochemical Fuel Production Process

Synthetic liquid fuels can provide a drop-in substitute for fossil-based fuels in sectors such as aviation and maritime, where electrification is not a viable option due to the need for high specific energy density. However, for these alternative fuels to be adopted at a commercial scale, their price must be competitive compared to their fossil-based counterparts. The reverse water-gas shift (RWGS) reaction offers a promising pathway, using hydrogen (sourced from electrolysis) and carbon dioxide as the feed and reacting to produce syngas - a mixture of H2 and CO at a specific ratio. Syngas is a useful precursor that can be converted into fuels and chemicals via known downstream processes, such as liquid transportation fuels via Fischer-Tropsch (FT) synthesis. The RWGS reaction is currently not applied in commercial scale, unlike the rest of the components in the process chain (electrolyzers and syngas-to-fuel synthesis units). The RWGS reaction poses several challenges due to its restrictive thermodynamics. Being an equimolar reaction, high temperatures and a large excess of H2 are needed to achieve reasonable CO2 conversion at equilibrium. This has detrimental effects on practical process implementation and the quality of syngas that can be produced, with direct effect on the energy and capital requirements, as well as the need for expensive downstream separation. In this work, we are proposing to develop a new concentrating solar thermal (CST) compatible RWGS reactor, performing the reaction in a 2-step chemical looping process using metal oxide at a temperature range of 600-800 degrees Celsius. By decoupling the reactor from the solar receiver, the Generation 3 (Gen3) CST technology could be utilized, together with its proposed thermal energy storage (TES) technology, benefitting from a good match to the required temperatures. CST technology is a viable option for supplying the heat that could be rapidly deployed in scale, thus being a good match to the gas-to-liquid (GTL) process which requires a large minimal scale to be commercially viable. The integration of TES with CST also allows operating the plant at large annual capacity factors and avoids multiple shutdown/startup cycles, thus fitting into the steady-state operation mode that most GTL processes require. The main innovation in the proposed design hinges on a countercurrent reaction design using a packed bed reactor. In 2019 Metcalfe et al. showed the benefits of countercurrent species exchange could be realized in a redox chemical-looping processes, by storing the favorable countercurrent chemical potential profiles in a packed bed of non-stoichiometric oxide. Metcalfe et al. applied this breakthrough concept to the WGS reaction, which is conventionally a co-feed catalytic process, showing a dramatic improvement. Bulfin et al. (2023) performed a similar proof-of-concept demonstration for the RWGS reaction using CeO2, achieving cumulative and peak CO2 conversions of 88% and 95%, respectively, compared to a thermodynamic limit of 58% for the co-feed catalytic process at the same conditions. In our new REGENLOOP project, we are developing a reactor prototype from the heat-exchange packed bed reactor-type, a commonly used reactor in the chemical industry. The endothermic heat of reduction will be supplied to the reactor using CST, while the same heat transfer fluid (HTF) mechanism will be used to extract the exothermic heat of oxidation. An array of multiple reactors is used to supply constant high-purity CO stream, that is then mixed with H2 from electrolysis to produce a high-purity syngas at the required composition. By removing the CO-CO2 separation after the RWGS process, significant energy and cost reduction can be achieved. A physics-based TEA framework is currently being developed, covering all the major plant processes, from the solar collection through storage, chemical looping RWGS, GTL, and auxiliary unit operations, up to the liquid hydrocarbon product. This modeling framework will utilize reduced-order models for the chemical looping RWGS and TES, CST modeling using SolarPILOT, and Aspen Plus for the GTL. By using this combined physics-based approach, the effects of design/operating parameters on the performance and cost can be elucidated. In our presentation, the modeling framework will be presented in detail, including preliminary cost predictions of using this plant configuration under a few selected relevant case studies. This study will be used to identify the major cost drivers, informing further system design and optimization needed to chart the way for a commercially viable pathway.

14 SOLAR ENERGY↗

Heat Integration Optimization and Dynamic Modeling Investigation for Advancing the Coal-Direct Chemical Looping Process

The purpose of the project is to address the optimization and startup operation of a modular coal direct chemical looping (CDCL) combustion system integrated with a steam cycle for power generation to reduce the risks involved in further scale-up of the technology. The modular reactor design of the CDCL process provides flexibility in the fabrication of the reactor and in its operating capacity (i.e. turndown ratio) at the cost of a more complex heat exchange network (HEN) design and integration. To address the technology gaps and advance the efficiency and economic feasibility of the CDCL technology, the project will perform a detailed and comprehensive analysis of the integration of a modular CDCL reactor system and a steam cycle system under both static and transient conditions via HEN process performance simulations and system dynamic modeling, respectively. The scope of work consists of 1) Experimental and computational studies of the CDCL combustor reactor 2) Comprehensive static (i.e. steady-state) system HEN design analysis in CDCL 550 MWe commercial unit for power generation and 3) Dynamic modeling of site specific design of 10MWe CDCL large pilot plant. The project team has successfully developed and validated a kinetic model for the oxidation of oxygen carriers in the combustor using the unreacted shrinking core model (UCSM). The model is capable of capturing the oxidation kinetics of fully or partially reduced oxygen carrier particles. A computational fluid dynamics (CFD) model is developed to simulate the hydrodynamics, heat transfer, and chemical reaction occurring in the CDCL combustor. The model is developed in MFIX and ANSYS Fluent. Key aspects of CDCL combustor operation, including heat transfer, oxygen carrier oxidation, and the transport of oxygen carrier particles, are simulated using this CFD model. The HEN for a commercial scale 550 MWe CDCL power plant is simulated and optimized using ASPEN Plus. Practical design considerations are incorporated based on industrial experiences. The performance and cost for the commercial CDCL plant is updated based on these analyses. A dynamic model for the 10 MWe CDCL pilot plant is developed in ProTRAX simulation software. The model is based on the pilot plant design developed in project DE-FE0027654 “10 MWe CDCL Large Pilot Plang – Pre-FEED Study” and the steam cycle data obtained from Dover Light & Power plant. The transient behaviors during pilot plant load variation are simulated using the dynamic model.

01 COAL, LIGNITE, AND PEAT↗

Commercially available Hydrogen Detection Systems for Corrosive, Oxygen-free Gas Streams: A Technical Summary

The growing use of hydrogen gas across energy, transportation, and chemical applications necessitates better hydrogen sensors and detectors. Few sensors exist for quantifying hydrogen gas in a corrosive, oxygen-free gas stream due to the challenging nature of the sampling environment and current technological status. Handheld, economic options include palladium-based, metal oxide, catalytic bead, and electrochemical sensors. More permanent and costly options include electrochemical sensors, thermal gas analyzers, mass spectrometers, gas chromatographs, and Raman spectrometers. In this technical report, a short review of current technology, along with the associated commercially available products, is provided. Raman spectroscopy is recommended as an ideal technology for on-line detection of hydrogen at low concentrations in a corrosive, oxygen-free gas stream.

08 HYDROGEN↗

Fabrication and Testing of DOE Standard Canister Closure Leak Test Assembly

DOE manages over 300 types of spent nuclear fuel (SNF), many of which are located at the Idaho National Laboratory (INL) site. Managing this large variety of SNF for storage, transportation, and disposal poses a challenge to DOE. The Idaho Cleanup Project and INL are collaborating on the DOE SNF Road-Ready Demonstration (“Road-Ready Demonstration”), which will develop and demonstrate the designs, technology, processes, and regulatory framework for packaging DOE-managed SNF for “road-ready dry storage.” Road-ready dry storage is an SNF management concept in which SNF is packaged into dry, sealed canisters that are then placed in onsite storage in anticipation of later transport and disposition. The forward-looking goal of the Road-Ready Demonstration is to establish the foundation for a large-scale road-ready dry storage program at the INL site. In support of establishing a large-scale road-ready dry storage program at the INL site, the Road-Ready Demonstration will first package Fort St. Vrain SNF currently in dry storage at INL into several DOE Standard Canisters (DOESCs). These DOESCs will in turn be loaded into another containment similar to commercial multi-purpose canisters. This multi-purpose canister will then be compatible with a transportation or storage system, such as a storage cask for interim storage or transportation package for offsite transport. These DOESCs will remain sealed over the course of their storage, transportation, and applicable disposal functions. The closure process for the DOESC will include fuel and basket loading, welding, inspection, leak testing, and, if needed, repair. As a follow-up to previous discussions on the design of the DOE Closure Leak Test Assembly (LTA), this report describes recent fabrication and testing efforts performed at INL. DOESCs are sealed by two sequential gas tungsten arc welds, both of which are performed by remotely operated and semiautomatic welding systems. The first weld is a circumferential pipe weld that completes the assembly of the canister body and lid assembly. The second and final closure weld attaches the vent plug to the vent socket via a butt joint. After the second weld is performed, the welds are helium leak tested using an evacuated envelope technique. The LTA was designed for both remote and manual operation. This report describes the fabrication and performance testing associated with the evacuated envelope technique. INL staff designed, fabricated, and tested the LTA at INL facilities. This testing included establishing technique and system sensitivities in accordance with ASME and American National Standards Institute N14.5 requirements. Forthcoming work will cover such areas as design optimization, process and personnel qualification, and implementation in Road-Ready Demonstration operations.

42 ENGINEERING↗

Fabrication and Testing of DOE Standard Canister Closure Leak Test Assembly – 24139

DOE manages over 300 types of spent nuclear fuel (SNF), many of which are located at the Idaho National Laboratory (INL) site. Managing this large variety of SNF for storage, transportation, and disposal poses a challenge to DOE. The Idaho Cleanup Project and INL are collaborating on the DOE SNF Road-Ready Demonstration (“Road-Ready Demonstration”), which will develop and demonstrate the designs, technology, processes, and regulatory framework for packaging DOE-managed SNF for “road-ready dry storage.” Road-ready dry storage is an SNF management concept in which SNF is packaged into dry, sealed canisters that are then placed in onsite storage in anticipation of later transport and disposition. The forward-looking goal of the Road-Ready Demonstration is to establish the foundation for a large-scale road-ready dry storage program at the INL site. In support of establishing a large-scale road-ready dry storage program at the INL site, the Road-Ready Demonstration will first package Fort St. Vrain SNF currently in dry storage at INL into several DOE Standard Canisters (DOESCs). These DOESCs will in turn be loaded into another containment similar to commercial multi-purpose canisters. This multi-purpose canister will then be compatible with a transportation or storage system, such as a storage cask for interim storage or transportation package for offsite transport. These DOESCs will remain sealed over the course of their storage, transportation, and applicable disposal functions. The closure process for the DOESC will include fuel and basket loading, welding, inspection, leak testing, and, if needed, repair. As a follow-up to previous discussions on the design of the DOE Closure Leak Test Assembly (LTA), this report describes recent fabrication and testing efforts performed at INL. DOESCs are sealed by two sequential gas tungsten arc welds, both of which are performed by remotely operated and semiautomatic welding systems. The first weld is a circumferential pipe weld that completes the assembly of the canister body and lid assembly. The second and final closure weld attaches the vent plug to the vent socket via a butt joint. After the second weld is performed, the welds are helium leak tested using an evacuated envelope technique. The LTA was designed for both remote and manual operation. This report describes the fabrication and performance testing associated with the evacuated envelope technique. INL staff designed, fabricated, and tested the LTA at INL facilities. This testing included establishing technique and system sensitivities in accordance with ASME and American National Standards Institute N14.5 requirements. Forthcoming work will cover such areas as design optimization, process and personnel qualification, and implementation in Road-Ready Demonstration operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recommendations for Secure Transport: Material Conveyance Physical Protection Technology

Nuclear material is at higher risk of theft and sabotage during transport than during any other phase of the nuclear fuel lifecycle. Nuclear materials are transported in the public domain where adversaries have an upper hand by taking advantage of the time and location of the theft or sabotage attempt. As such, even modest threat profiles for transport of nuclear and radioactive material can require substantial detection and delay measures to support timely response. Conveyance tracking augmented with technology that improves on-the-scene situational awareness at a remote monitoring center has been adopted as a de-facto standard approach for transportation security. At present, the extended tracking and situational awareness capabilities needed for a nuclear material shipment, as is provided by the purpose designed, Transportation – Security, Tracking and Reporting (T-STAR) System, do not exist in a single commercial off-the-shelf (COTS) solution. Typically, the COTS systems that excel in one area are deficient in other areas, presenting challenges to designing well-rounded, robust systems. Still, COTS solutions can offer the basic set of tracking and situational awareness capabilities by indicating last update time, current location, and route taken. By incorporating vehicle and driver performance measures via the vehicle’s controller area network (CAN bus) and video alongside other data streams allows telemetry and other shipment information to be assessed in novel ways.This paper describes the operation, capabilities and features of various conveyance protection systems and approaches, assesses emerging technologies and how they could be used through a unified interface, and enumerates additional ways to provide early detection using vehicle, onboard technologies, effective delay technologies and approaches and simple equipment to improve protection during transport.

Shannon, Michael↗

North Dakota Integrated Carbon Storage Complex Feasibility Study. Final report

In spring 2017, the Energy & Environmental Research Center (EERC) initiated an effort to determine the feasibility of developing a commercial-scale CO 2 geologic storage complex able to store 50+ million tonnes (Mt) of CO 2 in central North Dakota safely, permanently, and economically. The objective was to fulfill the goals of the U.S. Department of Energy (DOE) Carbon Storage Assurance Facility Enterprise (CarbonSAFE) Initiative and address technical and nontechnical challenges specific to commercial-scale deployment of a CO2 storage project. The findings clearly show that the concept of capturing CO 2 from a lignite-fired electrical generation facility in central North Dakota and safely and permanently storing the CO 2 in the deep subsurface is indeed technically, economically, and socially feasible. This project evaluated two study areas and their respective geologic storage complexes located adjacent to separate coal-fired facilities in North Dakota: the Basin Electric Power Cooperative (BEPC)-owned Great Plains Synfuels Plant (GPSP) and the Minnkota Power Cooperative (Minnkota)-owned Milton R. Young Station (MRYS). These locations, one with CO 2 capture in place and an existing CO 2 pipeline, are bolstered by progressive North Dakota pore space ownership and long-term liability laws. These elements and a motivated team created an ideal synergistic scenario for ensuring success of the CarbonSAFE Initiative and promoting North Dakota’s statewide vision for carbon management. The project included drilling two new geologic characterization wells, integrating an existing 3-D seismic survey, creating a geologic model subsequently used for injection simulation, a risk assessment, public outreach, and generating a site development plan based on results. In addition, the performance of select National Risk Assessment Partnership tools was evaluated. The geologic characterization wells were drilled ~5600 feet deep to the Broom Creek Formation; ~350 feet of core was retrieved from each well. The core included the Broom Creek (targeted injection zone) and a portion of the overlying Opeche Shale (seal). The Flemmer-1 well, west of Beulah, North Dakota, yielded 169 feet of sandstone. The BNI-1 well located south of Center, North Dakota, yielded 124 feet of sandstone. In each case, laboratory analysis of the sandstone showed permeability in the 300–1000-mD range, with porosity of 20%–30%. The Flemmer-1 well was sited within the boundaries of an existing 3-D seismic survey. Colocating the well with the seismic survey maximized the relationship between new and legacy data and developed a first-of-its-kind interpretation of the geologic fabric of the Broom Creek. Geologic characterization data were integrated into a 5544-mi 2 geocellular model that encompassed both new wells and stratigraphy from the surface to the Amsden Formation (underlying the Broom Creek). The model was later expanded vertically to include the deeper Black Island–Deadwood interval to examine its potential viability as a storage target. The geocellular model provided the foundation for dynamic simulation of CO 2 into the Broom Creek. Results of the simulation suggest that the Broom Creek could accept the DOE target rate of 2 Mt/yr of CO 2 into as few as two wells. To bracket the expected capture from MRYS, simulations were also investigated for a 4-Mt/yr rate near MRYS. Although more wells are needed (two additional), the Broom Creek still has the storage resource to accept the CO 2 at the increased rate. A risk assessment exercise was conducted to identify and assess technical and nontechnical risks that could prevent potential candidate storage complexes within the study area from serving as commercial storage sites. The assessment identified and evaluated six technical risk categories: 1) CO 2 injectivity, 2) storage capacity, 3) lateral migration of CO 2 , 4) lateral pressure propagation, 5) vertical migration of CO 2 or formation brine, and 6) induced seismicity. Following two rounds of analysis and scoring, no risks were determined to preclude continued efforts to develop carbon capture, utilization, and storage (CCUS) in central North Dakota. The risk assessment results will be used to guide future site characterization, modeling and simulation, and monitoring activities. A specific nontechnical strategic risk based on challenges that may be realized in amalgamation of pore space resulted in vertically expanding the geologic model to incorporate the potential for stacked storage in multiple saline reservoirs. By including the Black Island–Deadwood interval (the basal sedimentary reservoir in this region), the amalgamated areal extent could be reduced by as much as 45%. Working with a smaller geographic area reduces risks and costs associated with monitoring and pore space leasing. An economic evaluation incorporating capture; transport (<5 mi); Class VI wells; permitting; and monitoring, verification, and accounting suggests implementing commercial-scale CCUS is economically attractive if the federal tax benefits of 45Q are included. This is validated by Minnkota’s continued pursuit of CO 2 capture and geologic storage at MRYS through its Project Tundra initiative, indicating that there is a business case for CCUS in central North Dakota. Currently, North Dakota is the only state with underground injection control (UIC) Class VI primacy. Built into the North Dakota Century Code is a series of regulatory requirements that guide the process to obtain a Class VI CO 2 storage facility permit. As part of this project, a site development plan was compiled to assure compliance with North Dakota’s requirements to permit a commercial-scale CO 2 storage operation and includes a prospective time line encompassing a general breakdown of activities. In total, an estimated 30 months would be needed to execute the necessary steps to attain a North Dakota CO 2 storage facility permit. Outreach was an integral part of the project and encompassed any project-related activity that had contact or exposure beyond the project team. The goals of outreach were to foster an environment from which stakeholders could make informed decisions about the project and gauge community receptiveness to a CCUS project. A consistent set of messages and outreach products were developed in conjunction with an outreach advisory board that integrated project partners and team members. To gauge public acceptability of geologically storing CO 2 , 5611 households in the project area were invited to participate in an online survey. The survey results indicate that the public attitude regarding CCUS is neutral to positive, with strong sentiment that CO 2 capture and storage may be an approach to maintain the economic vitality of the region. To achieve project objectives, critical support in the form of financial backing, engineering evaluations, site access, outreach collaboration, operations data, risk assessment/evaluation, and software access was provided by BEPC, the North Dakota Industrial Commission Lignite Research Council, ALLETE Clean Energy, BNI Energy, North American Coal Corporation, Minnkota, Prairie Public Broadcasting, Computer Modelling Group Ltd., and Schlumberger.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗