Search NASA⌕ Search

SEARCH · Search NASA

Results for “Contaminated data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Risk Evaluation for the Diesel Fuel Leak Near Generator Building TRA-674 at the Advanced Test Reactor Complex

This report describes the risk-based evaluation conducted for the underground diesel fuel leak near Generator Building TRA-674 at the Advanced Test Reactor Complex, located at the Idaho National Laboratory. The risk evaluation process followed the Idaho Risk Evaluation Manual for Petroleum Releases (August 2012) guidance document and used the Idaho Risk Evaluation Computational Software (August 2015) to estimate the human health risks posed by residual contamination. Site-specific data were collected to estimate the representative concentrations of the soil for estimating the cumulative risk. Based on historical and current data, the site does not exceed unacceptable risk to human health receptors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Using ARM Data to Retrieve Entrainment Rates in Stratocumulus Cloud Systems (Final Report)

A stratocumulus-topped boundary layer (STBL) is a shallow convecting layer in which both the updraft and the downdraft branches of the convective circulation are saturated (cloudy) in the upper part of the boundary layer. The convective circulation is vigorous, yet the cloud-top entrainment velocity, $w_e$, is small and difficult to measure. Differences between currently used parameterizations of $w_e$ in GCMs can lead to STBLs that differ by as much as a factor of two in climatologically important properties such as liquid water path and boundary layer depth. We have developed a new method to retrieve entrainment rates in STBLs which uses vertical velocity retrievals from surface-based cloud radar, in conjunction with other surface-based measurements. These new estimates will allow a more comprehensive evaluation of parameterizations of entrainment rate for STBLs. The new method will also provide ground-based estimates of entrainment in STBLs over long time periods. We use retrievals of vertical velocity and liquid water content profiles to estimate the turbulent liquid water flux, which is then used in combination with observed cloud-top jumps of temperature, water vapor, and calculated radiative flux profiles to estimate the entrainment rate. We present results for three days for which observational data was not significantly contaminated by drizzle. The resulting average entrainment rates are 0.58 cm/s, 1.51 cm/s, and 0.31 cm/s.

54 ENVIRONMENTAL SCIENCES↗

The BROOM system.

The Building Restoration Operations Optimization Model (BROOM) is a software product developed to assist in the restoration of major transport facilities in the event of an attack involving chemical or biological materials. As shown in Figure 3-1, the objective of this work is to replace a manual, paper-based data entry and tracking system with an electronic system that should be much less error-prone. It will also manage the sampling data efficiently and produce contamination maps in a more timely manner.

99 GENERAL AND MISCELLANEOUS↗

Well Design, Operation and Maintenance and Proactive Rehabilitation to Optimize Remediation Well Performance - 18605

Optimizing performance of extraction, injection and monitoring wells, which are integral components of groundwater remediation systems, result in lower life cycle costs and a higher probability of meeting project objectives. These wells provide the means to extract contaminated groundwater, inject reagents, treated water and clean water to create groundwater reaction/flushing zones, and to provide groundwater level, contaminant concentration and geochemical data. Initial costs associated with well installation and associated pipelines and treatment systems are significant project expenditures related to site remediation. However, the life cycle costs for wells are dominated by the long-term operation and maintenance (O and M) expenditures. Remediation wells are particularly susceptible to various types of fouling that impact well performance and, therefore, drive up operating costs. Simply defined, fouling is the result of any biological, geochemical or physical process that negatively impacts the intended performance of a remediation well. Fouling decreases well performance by effectively reducing hydraulic communication between the well and the surrounding formation. Oftentimes this occurs via clogging screens and/or gravel pack/formation pore space by bacterial or chemical byproducts and gases, which can lead to corrosion of metal components and spreading fouling deposits to pipelines and surface treatment systems. Ultimately, this results in reduced hydraulic performance in extraction and injection wells and result in erroneous water level and chemical parameter concentration measurements in monitoring wells. Remediation well fouling cannot be eliminated, and natural fouling processes are exacerbated by the installation and operation of remedial systems. Steps required to extend the life of remediation wells and to lower life cycle costs are discussed in this paper in order to establish the required approach to effective system management. These optimization approaches have been developed through years of operation and maintenance of complex large-scale plume remediation systems utilizing a variety of subsurface in-situ and ex-situ technologies. Remediation well performance can be improved by: - careful site characterization, - appropriate well design, - proper well installation and development, - thoughtful and adaptable operation and maintenance, - well performance maintenance tracking and, - proactive well rehabilitation. Clear understanding of the site hydro-stratigraphy and geochemical settings places constraints on the compatibility of well materials and the configurations of well screens. Proper well design, including collection and analysis (sieve/grain-size) of screen zone formation samples, assures that wells can be optimally installed, developed and redeveloped during well rehabilitation. Design considerations should include proper sizing of filter packs and well screens, casing/screen diameter, well material selection/compatibility, expected life/use, and well head configuration to allow for future access. Applying appropriate and effective well installation and development methods are of paramount importance and rely on a good understanding of site characteristics (e.g., geologic setting) as well as local drilling company expertise and experience. Different approaches to operation and maintenance can greatly affect the degree of fouling, these include limiting reagent concentrations, maintaining submerged well screens and filtering injection water to prevent the introduction of fouling enhancing constituents. Tracking well performance by monitoring changes in system operation and metrics such as specific capacity or injectivity for extraction and injection wells, respectively, or turbidity and chemical analyses for monitoring wells is key to identifying well maintenance issues early when well rehabilitation can be most effective. Proactive well rehabilitation can include mechanical brushing, surging and jetting, chemical treatment or other specialized approaches; however, the approach needs to be based on a site-specific understanding of the predominant fouling mechanisms. Collection and analyses of fouling deposits can provide guidance for selection of rehabilitation methods and chemicals that will be most effective. Application of these approaches have led to extended operational life for reagent injection wells, which can foul quickly, from months to years. Additionally, proper maintenance will often lead to increased and extended productivity of the well. For extraction wells, this translates to a higher sustainable yield, which means shorter cleanup times. Similarly, for injection wells, proper maintenance allows for the introduction of a greater volume of reagents over a shorter period, thus, shorter cleanup times that reduce overall project costs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Natural Gas Drilling near the Underground Nuclear Test Site of Rulison, Colorado - 19571

In 1969, the Project Rulison test was conducted in western Colorado using a nuclear device to stimulate natural gas production by fracturing low-permeability, gas-bearing rock. The presence of radionuclides (specifically tritium) in the produced gas persisted above acceptable levels, and the test was abandoned. Advances in hydrofracturing technology over the past 10-15 years have revolutionized the extraction of hydrocarbons from low-permeability formations, leading to a significant increase of drilling in the Rulison area. Drilling activity nearing the Rulison site has raised concerns that remnant radioactivity might be encountered. The site, now under the care of the US Department of Energy (DOE), is protected by a 16-hectare (40 acre) institutional control boundary (Lot 11) that prohibits drilling or extraction of materials below 1830 meters (6000 feet) within the lot boundary. Drilling within 0.8 kilometer (0.5 mile) of the site requires a hearing before the Colorado Oil and Gas Conservation Commission. DOE recommends that gas developers adopt a conservative, staged drilling approach, allowing gas reserves near the Rulison site to be recovered in a manner that minimizes the likelihood of encountering contamination. The staged approach calls for collecting data from wells away from the site before drilling closer. For instance, the wells 1.2 kilometer (0.75 mile) west of the site did not encounter any unexpected geologic conditions and now have 8 years of production without encountering any detonation-related radionuclides. The next set of wells would be 0.8 kilometer (0.5 mile) west of the site. This sequential method drills first at locations with a low probability of encountering contamination and then moves closer. This process protects public safety while allowing the collection of additional data to confirm that contamination has not migrated beyond the 16-hectare (40-acre) institutional control boundary. The staged drilling approach was simulated with a modeling effort that estimates the current extent of contamination and the potential for production-induced contaminant migration to nearby wells. The model incorporates geologic data from nearby wells and was calibrated to production data from both the reentry well production testing (1970-1971) and the wells 1.2 kilometer (0.75 mile) from the site that began producing in 2010. The geologic data include both sand/shale distribution statistics as well as the tendency of hydrofractures to preferentially propagate east and west due to the regional stress field. The model results indicate that it is unlikely that wells near the site would ever encounter site-related radionuclides. (authors)

03 NATURAL GAS↗

A Data-driven Phytotechnology Framework for Identification and Remediation of Leached-Metals-Contaminated Soil Near Coal Ash Impoundments

This project developed and evaluated advanced remote sensing and machine learning approaches to identify, monitor, and address environmental contamination associated with coal combustion residual (CCR) impoundments and landfills at coal-fired power plants. In Phase I, historical and multi-temporal Sentinel-2 satellite imagery, groundwater monitoring data, and environmental variables were integrated to detect vegetation stress potentially caused by toxic metal leaching from coal ash disposal sites. Multiple vegetation and biophysical indices were analyzed to determine their effectiveness in identifying abnormal vegetation growth patterns linked to contamination. Results from case studies conducted at coal ash–impacted power plant sites in North Carolina and Virginia demonstrated that satellite-based vegetation monitoring can serve as an effective early indicator of environmental stress associated with metals such as arsenic, cadmium, cobalt, lead, lithium, radium, and thallium.

01 COAL, LIGNITE, AND PEAT↗

Multi-Faceted Approach to Evaluate Discharge Locations at a FUSRAP Site - 18421

Following the completion of a Soil and Groundwater Remedial Investigation by USACE at a FUSRAP site located in Nassau County, New York, groundwater data indicated the presence of contaminant source(s) that had not been identified. As a result, a targeted investigation was undertaken to understand how materials were handled and disposed of at a site located in Nassau County, Long Island, New York. The FUSRAP site is a 4.3-hectare (10.5-acre) site encompassing three parcels which had historically been utilized as a nuclear materials manufacturing facility (e.g., cores, slug, and fuel elements) for reactors used in both research and electric power generation in early 1950's until late 1960's; however, the targeted investigation was on the southern-most parcel known as the '70 Property' (the Site). The 70 Property contained a building that was used for atomic fuel-element manufacturing from 1958 until 1966 under license to the Atomic Energy Commission (AEC), and involved the use of natural, enriched, and depleted uranium as well as lesser amounts of thorium. The major contaminants of concern are tetrachloroethene, nickel, uranium and thorium. During the RI, significant sources of contamination were not found in Site soils despite records indicating that chemicals and radionuclides had been disposed of on the property. In addition, downgradient groundwater data indicated a source(s) on the 70 Property that could not be identified by known sources on other the other FUSRAP parcels or from adjacent sites. This conclusion was further supported following development of groundwater contaminant transport and flow models. The main objective of the targeted investigation was to evaluate the potential discharge points on the 70 Property that may have been utilized for liquids waste disposal. However, several challenges existed including 1) lack of building construction details; 2) historical changes to Site building and property; 3) the use of the Site by various tenants; and 4) the commingling of Site contaminants with impacts from multiple sources. To overcome these challenges, historic documents/reports with information about the handling and disposal of liquid wastes were reviewed to evaluate quantities, contents and locations of waste disposal. Thereafter, an investigation was undertaken that included geophysical surveys; pipe tracing and video inspection; in-situ smoke and water testing; installation of test trenches and soil borings; and, sampling sludge residuals, soils and water within the various drainage structures that were located. This paper describes the multi-faceted investigation approach that was utilized to overcome the challenges faced during the investigation as well as insights into the waste disposal practices of the time period and the findings of the investigation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Effect of Airborne Contaminants on Fuel Cell Performance and Durability

The impact of contaminants on fuel cell performance was examined to document air filter specifications (prevention) and devise recovery procedures (maintenance) that are effective at the system level. Eight previously undocumented airborne contaminants were selected for detailed studies and characterization data was used to identify operating conditions that intensifying contamination effects. The use of many and complementary electrochemical, chemical and physical characterization methods and the derivation of several mathematical models supported the formulation of contamination mechanisms and the development of recovery procedures. The complexity of these contamination mechanisms suggests a shift to prevention and generic maintenance measures. Only two of the selected contaminants led to cell voltage losses after injection was interrupted. Proposed recovery procedures for calcium ions, a component of road de-icers, dessicants, fertilizers and soil conditioners, were either ineffective or partly effective, whereas for bromomethane, a fumigant, the cell voltage was recovered to its initial value before contamination by manipulating and sequencing operating conditions. However, implementation for a fuel cell stack and system remains to be demonstrated. Contamination mechanisms also led to the identification of membrane durability stressors. All 8 selected contaminants promote the formation of hydrogen peroxide, a known agent that can produce radicals that attack the ionomer and membrane molecular structure whereas the dehydrating effect of calcium ions on the ionomer and membrane increases their brittleness and favors the creation of pinholes under mechanical stresses. Data related to acetylene, acetonitrile and calcium ions are emphasized in the report.

33 ADVANCED PROPULSION SYSTEMS↗

Laboratory Activities

This chapter summarizes the laboratory activities performed by PNNL’s Vadose Zone Characterization Project in support of the Tank Farm Vadose Zone Program, led by CH2M HILL Hanford Group, Inc. The results of these studies are contained in numerous reports (Lindenmeier et al. 2002; Serne et al. 2002a, 2002b, 2002c, 2002d, 2002e; Lindenmeier et al. 2003; Serne et al. 2004a, 2004b; Brown et al. 2005, 2006a, 2007; Serne et al. 2007) and have generated much of the data reported in Chapter 22 (Geochemistry-Contaminant Movement), Appendix G (Geochemistry-Contaminant Movement), and Cantrell et al. (2007, SST WMA Geochemistry Data Package – in preparation). Sediment samples and characterization results from PNNL’s Vadose Zone Characterization Project are also shared with other science and technology (S&T) research projects, such as those summarized in Chapter 12 (Associated Science Activities).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Complexity of Groundwater Contaminants at DOE Sites

The U.S. Department of Energy (DOE) is responsible for the remediation and long-term stewardship of one of the world's largest groundwater contamination portfolios, with a significant number of plumes containing various contaminants, and considerable total mass and activity. As of 1999, the DOE's Office of Environmental Management was responsible for remediation, waste management, or nuclear materials and facility stabilization at 144 sites in 31 states and one U.S. territory, out of which 109 sites were expected to require long-term stewardship. Currently, 19 DOE sites are on the National Priority List. The total number of contaminated plumes on DOE lands is estimated to be 10,000. However, a significant number of DOE sites have not yet been fully characterized. The most prevalent contaminated media are groundwater and soil, although contaminated sediment, sludge, and surface water also are present. Groundwater, soil, and sediment contamination are present at 72% of all DOE sites. A proper characterization of the contaminant inventory at DOE sites is critical for accomplishing one of the primary DOE missions -- planning basic research to understand the complex physical, chemical, and biological properties of contaminated sites. Note that the definitions of the terms 'site' and 'facility' may differ from one publication to another. In this report, the terms 'site,' 'facility' or 'installation' are used to identify a contiguous land area within the borders of a property, which may contain more than one plume. The term 'plume' is used here to indicate an individual area of contamination, which can be small or large. Even though several publications and databases contain information on groundwater contamination and remediation technologies, no statistical analyses of the contaminant inventory at DOE sites has been prepared since the 1992 report by Riley and Zachara. The DOE Groundwater Data Base (GWD) presents data as of 2003 for 221 groundwater plumes at 60 DOE sites and facilities. Note that Riley and Zachara analyzed the data from only 18 sites/facilities including 91 plumes. In this paper, we present the results of statistical analyses of the data in the GWD as guidance for planning future basic and applied research of groundwater contaminants within the DOE complex. Our analyses include the evaluation of a frequency and ranking of specific contaminants and contaminant groups, contaminant concentrations/activities and total contaminant masses and activities. We also compared the results from analyses of the GWD with those from the 1992 report by Riley and Zachara. The difference between our results and those summarized in the 1992 report by Riley and Zachara could be caused by not only additional releases, but also by the use of modern site characterization methods, which more accurately reveal the extent of groundwater contamination. Contaminated sites within the DOE complex are located in all major geographic regions of the United States, with highly variable geologic, hydrogeologic, soil, and climatic conditions. We assume that the information from the 60 DOE sites included in the GWD are representative for the whole DOE complex. These 60 sites include the major DOE sites and facilities, such as Rocky Flats Environmental Technology Site, Colorado; Idaho National Laboratory, Idaho; Savannah River Site, South Carolina; Oak Ridge Reservation, Tennessee; and Hanford Reservation, Washington. These five sites alone ccount for 71% of the value of the remediation work.

54 ENVIRONMENTAL SCIENCES↗

Integrated Modeling and Monitoring Technologies for Environmental Resiliency in Nuclear Energy

Environmental concerns pose the biggest challenge for the development of the nuclear energy industry, often preventing or limiting the construction of new plants and radioactive waste disposal facilities. There are currently numerous sites in the world at which surface and groundwater are contaminated by nuclear weapon production and testing, as well as due to nuclear power plant accidents. Many of those sites remain unused or inhabited primarily due to public concern. Improving scientific and technical capabilities to develop environmental resiliency is critical not only to address existing contamination, but also to build public confidence and support for nuclear energy. One of the obstacles in remediation is to tackle a large volume of contaminated soil and groundwater with relatively low concentrations. Although many contaminant removal technologies have developed (e.g., pump-and-treat systems), they are often expensive and not cost-effective for low-concentration radionuclide contamination. Although soil removal is often the most effective, it produces a large amount of waste that has to be stored securely for a long period of time or treated at the special treatment facilities. Transporting a large amount of waste may also produce greenhouse gases and disrupt local communities. Recently, the concept of 'sustainable remediation' has been proposed to improve a remediation system as a whole, including the consideration of cost effectiveness, reduction of greenhouse emission, waste production and energy usage. Rather than just focusing on removing contaminants, the sustainable remediation highlights the use of passive remediation technologies to immobilize radionuclides along with the application of monitored natural attenuation and longer institutional control. However, such passive technologies and monitored natural attenuation require the increased burden of proof to ensure that those immobilized contaminants would not compromise the long-term public health. Although contaminant transport modeling and risk assessments are always performed, they sometimes fail due to the lack of understanding the contaminant transport proposes at the time of the risk assessment or due to some unexpected processes. Monitoring technologies are critical to ensure the long-term stability of such remediated sites, and also to address the public concerns. Recent advances in in situ sensor technologies and spatially-extensive mapping technologies (such as unmanned aerial vehicles, airborne mapping, geophysics) have improved monitoring of contamination over space and time. In addition to new sensing devices, data management and data analytics technologies have been expanded to manage and process large spatial and temporal datasets. Such technologies can be used to reduce monitoring cost significantly, and to facilitate long-term monitoring. In this study, we demonstrate our data analytics technologies for two nuclear-related contaminated sites: (1) air dose rate monitoring in Fukushima prefecture, and (2) groundwater monitoring at the Savannah River Site F-Area. We are developing the spatial and temporal data integration methodologies to integrate various spatially extensive data and time-series data for improving long-term monitoring. Such monitoring technologies and experiences at the existing contaminated sites can be transferred to build a better monitoring system for nuclear facilities, such as nuclear power plants or nuclear waste storages.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A background correction algorithm for Van Allen Probes MagEIS electron flux measurements

We describe an automated computer algorithm designed to remove background contamination from the Van Allen Probes Magnetic Electron Ion Spectrometer (MagEIS) electron flux measurements. We provide a detailed description of the algorithm with illustrative examples from on-orbit data. We find two primary sources of background contamination in the MagEIS electron data: inner zone protons and bremsstrahlung X-rays generated by energetic electrons interacting with the spacecraft material. Bremsstrahlung X-rays primarily produce contamination in the lower energy MagEIS electron channels (~30–500 keV) and in regions of geospace where multi-M eV electrons are present. Inner zone protons produce contamination in all MagEIS energy channels at roughly L < 2.5. The background-corrected MagEIS electron data produce a more accurate measurement of the electron radiation belts, as most earlier measurements suffer from unquantifiable and uncorrectable contamination in this harsh region of the near-Earth space environment. These background-corrected data will also be useful for spacecraft engineering purposes, providing ground truth for the near-Earth electron environment and informing the next generation of spacecraft design models (e.g., AE9).

47 OTHER INSTRUMENTATION↗

Quantifying the Impact of Excluding the Submersion Exposure Route for Existing Superfund Radionuclide Screening Level Calculator Soil and Tap Water Models

The U.S. Environmental Protection Agency (EPA) provides initial data screening guidelines for radionuclide-contaminated Superfund sites using preliminary remediation goals (PRGs) and dose compliance concentrations (DCCs). PRGs and DCCs are target concentration values based on acceptable excess lifetime cancer risk and annual dose limits, respectively. They are calculated for various environmental media that may be encountered by residential and worker land uses. PRGs and DCCs typically consist of multiple exposure routes. One of these routes is submersion, which is exposure to a gaseous or particulate radionuclide that is suspended in air. Currently, submersion is only included in air calculations. This study focused on determining whether factoring submersion into total PRG/DCC calculations for soil and tap water created a significant difference in the target concentrations. New equations for individual submersion PRGs/DCCs for each land use of interest for soil and tap water were developed. A wind-driven particulate emission factor and Andelman’s constant were used to model the amount of soil and vapor in the air from soil and household use of tap water, respectively. The submersion PRG/DCC was then included in the total PRG/DCC for each radionuclide, followed by a percent difference comparison of the old and new totals to quantify the impact of the change. For total soil PRGs/DCCs, with and without submersion, the difference was less than 1 percent; however, many of the tap water radionuclides analyzed – including multiple radon and polonium isotopes – showed as high as a 200 percent difference.This technical memorandum (TM) presents recommendations for updates to current EPA guidelines for initial data screens of radionuclide contaminated tap water.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling and Optimization of Zeolites for Contaminant Removal from Coal Combustion Impoundment Leachates

Coal Combustion Residual (CCR) landfills in the U.S. can lead to elevated contaminant concentrations in groundwater and runoff, particularly of arsenic, boron, and selenium. Zeolites can be readily synthesized from materials contained within the coal combustion ash impoundments and can be cation-exchanged to enhance adsorption capacity, selectivity, and reactivity. However, the optimization of zeolites becomes a daunting task when accounting for the variety of Si:Al ratios, the species of extra-framework cations present, and the zeolite pore structure. Molecular simulations provide methods to study and guide the design of zeolites for the sorption of contaminants from aqueous solution. In this work, models that predict the sorption of arsenic, boron, and selenium from water using cation-exchanged zeolites. Because of the lack of experimental adsorption data for these species of contaminants, models were parametrized to reproduce the results of first-principles calculations and then used to predict sorption for zeolites for a dataset containing 6000 combinations of zeolites and sorption conditions. Machine learning was used to train a model to predict sorption for materials in this database based on the results of the molecular simulations. Next, a genetic algorithm was used to optimize zeolites for the removal of each contaminant from aqueous solution for individual impoundment sites based on contaminant concentrations reported by the Electric Power Research Institute.

Findley, John↗

Why Use Geo-statistics For Nuclear Decommissioning Projects? - 15567

Before nuclear facilities are dismantled, and contaminated sites remediated, their initial radiological state must be characterized. Combining historical information, non-destructive measurements and lab analysis results, the statistical method of geo-statistics allows all available data for 2D or 3D contamination mapping to be integrated and enhanced, and helps quantify estimation uncertainties. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nevada National Security Site 2018 Data Report: Groundwater Monitoring Program, Area 5 Radioactive Waste Management Site

This report is a compilation of the groundwater and waste cell leachate sampling results from the Area 5 Radioactive Waste Management Site (RWMS) at the Nevada National Security Site, Nye County, Nevada. Groundwater samples from the aquifer immediately below the Area 5 RWMS have been collected and analyzed and static water levels have been measured in this aquifer since 1993. These groundwater data are evaluated for evidence of effects on the aquifer related to the Area 5 RWMS. Leachate from one lined mixed waste cell at the Area 5 RWMS (Cell 18) has been sampled since the cell opened in 2011. These leachate data are analyzed for hazardous contaminants to determine appropriate leachate handling and disposal. A second lined mixed waste cell at the Area 5 RWMS (Cell 25) began receiving waste in August 2018, but no leachate samples were collected or analyzed during 2018. This report includes data from 2014 through 2018 but focuses on the 2018 data. During 2018, groundwater samples were collected and static water levels were measured at three wells surrounding the Area 5 RWMS. Groundwater samples were collected at wells UE5PW-1, UE5PW-2, and UE5PW-3 on March 6 and August 14, 2018. Static water levels were measured at each of these wells on March 5, June 4, August 13, and October 25, 2018. Groundwater monitoring at the Area 5 RWMS complies with Title 40 Code of Federal Regulations (CFR) Part 264.97, General ground-water monitoring requirements , and 40 CFR 264.98, Detection monitoring program. Groundwater samples were analyzed for indicators of contamination (pH, specific conductance [SC], total organic carbon, total organic halides, and tritium) and, beginning in 2017, toxicity characteristic metals (arsenic, barium, cadmium, chromium, lead, mercury, selenium, and silver). General water chemistry parameters (calcium, iron, magnesium, manganese, potassium, sodium, sulfate, chloride, fluoride, bicarbonate, and silicate) were also measured. Results from samples collected in 2018 are within the limits for each parameter established by the Nevada Division of Environmental Protection in Resource Conservation and Recovery Act (RCRA) Permit NEV HW0101, Revision 6. Data from the shallow aquifer indicate there has been no measurable impact to the uppermost aquifer from the Area 5 RWMS, and there were no significant changes in measured groundwater parameters compared to previous years. Leachate from lined mixed waste Cell 18 drains into a sump and is pumped into an above ground tank. Samples are collected from the tank when the leachate volume approaches the 3,000-gallon tank capacity. During 2018, leachate samples were collected on March 1, 2018 and August 1, 2018. All leachate analysis results are below the regulatory levels for toxicity characteristic contaminants (40 CFR 261.24) and below the investigation levels for polychlorinated biphenyls (PCBs), tritium, pH, and SC specified in RCRA Permit NEV HW0101, Revision 6. No quantifiable PCB levels were detected in any leachate sample. Based on the leachate analysis results, RCRA Permit NEV HW0101 allowed all leachate collected from Cell 18 to be pumped from the collection tank and used for dust control at Cell 18.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Immunomodulatory effects of exposure to polychlorinated biphenyls and perfluoroalkyl acids in East Greenland ringed seals (Pusa hispida)

To better elucidate the potential immune-related health effects of exposure to environmentally persistent organic pollutants (POP), such as polychlorinated biphenyls (PCBs) and perfluoroalkyl substances (PFASs), in ringed seals (Pusa hispida), a sentinel Arctic species, we assessed 1) associations between mitogen-induced lymphocyte proliferation and in vivo tissue contaminant burdens, and 2) the concentration-response effects of in vitro exposure to PFASs and PCB congeners on mitogen-induced lymphocyte proliferation. Upon in vitro contaminant exposure, the non-coplanar PCB congeners CB 138, 153, and 180, but not the coplanar CB 169, significantly reduced lymphocyte proliferation between 10 and 20 µg g{sup −1} ww. The respective in vitro EC{sub 50} values for these congeners were 13.3, 20.7, 20.8, and 54.6 µg g{sup −1} ww. No modulation of lymphocyte proliferation was observed upon in vitro exposure to two individual PFASs, perfluorooctane sulphonic acid (PFOS) and perfluorooctanoic acid (PFOA), at concentrations up to 1000 ng g-1. In addition, no significant correlations were found between lymphocyte proliferation and any blood or blubber contaminant measured. Taken together, these data suggest this population of ringed seals is not currently at high risk of altered lymphocyte proliferation from exposure to the POPs or PFASs in this study. - Highlights: • Assess relationships between tissue contaminants and changes in immune function. • Risk for contaminant-induced immunotoxicity in East Greenland ringed seal is low. • Weight of evidence suggest non-coplanar PCBs are immunotoxic at high concentrations.

54 ENVIRONMENTAL SCIENCES↗