Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control Model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A New Distributed Model-Free Control Strategy to Diminish Distribution System Voltage Violations

This paper proposes a new distributed model-free control (MFC) strategy for dynamic voltage control to diminish distribution systems' voltage violations. The objective is to maintain all critical load bus voltages within the acceptable ANSI Range A (+/- 5% of nominal). The distributed MFC strategy, which only requires local voltage measurements from designated load buses, controls online the reactive power generation of available synchronous generator (SG)-based and photovoltaic (PV)-based distributed generators (DGs). The distributed MFC strategy is computationally efficient and does not require modelling of the different system components and disturbances. Time-domain dynamic simulations are conducted for the 21-bus test distribution system fed by multiple DGs to verify the performance of the proposed MFC strategy, and the results are compared against the conventional model-based microgrid voltage stabilizer (MGVS) control strategy. The simulation results show that the distributed MFC strategy provides minimal voltage violations and achieves the dynamic voltage stability of the system under diverse disturbances.

Hatipoglu, Kenan↗

An Average Model Predictive Control of Quasi-Z-Source Modular Cascaded Photovoltaic Converter

An average model predictive control (AMPC) is proposed for dc grid integration of the front-end isolated quasi-Z-source modular cascaded converter (qZS-MCC) photovoltaic (PV) power system. The qZS-MCC deals with PV maximum power point tracking (MPPT), dc grid integration, and de-link voltage balance by the post-stage qZS half-bridge (HB) dc-dc converters, while a unified duty cycle is used in the front-end isolation converters of all submodules (SMs). Thus, it reduces the control resources while overcoming the dc-bus voltage limit because of the PV panel insulation demand. The proposed AMPC of qZS-MCC PV power system predicts the shoot-through duty cycle of each SM for dc-link voltage control, and the total modulation index for dc grid-connected current control; only one proportional-integral (PI) regulator for PV MPPT is required in each SM. Thus, PI regulators are significantly reduced, whereas system dynamic responses are improved, with low computation and simple implementation. Simulation and downscaled experimental results demonstrate the effectiveness of the proposed control.

Liu, Yushan↗

Reinforcement learning for online adaptation of model predictive controllers: Application to a selective catalytic reduction unit

Here we present a novel application of reinforcement learning (RL) for online dynamic tuning of model predictive controllers (MPC). Applying a state-action-reward-state-action (SARSA) algorithm for temporal difference learning with a control-specific reward function improves the error tracking performance of a standard MPC formulation. The proposed RL approach is also readily adaptable to other MPCs, or entirely different control approaches. Practical details for the implementation of the RL-MPC algorithm are also presented. The proposed algorithm is applied to a case study of controlling nitrogen oxide (NO x ) emissions in an industrial selective catalytic reduction (SCR) unit, a control problem characterized by significant nonlinearity and time delay. Along with an RL-MPC formulation for NOx control, another MPC is proposed to mitigate ammonia slip and decrease ammonia consumption in the SCR. Results showing the efficacy of the RL-MPC for NO x control through learning and implementation on the nonlinear SCR dynamic model are presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microreactor Automated Control System - Digital Twin Models and Advanced Control Systems Updates

Automation of control systems is expected to be important in the economic and safe operation of microreactors. Therefore, there is a need to develop and demonstrate automated control for microreactors, along with the development of testbeds for this purpose. This report provides updates on the status of a nonnuclear microreactor automated control system (MACS)—a real-time, hardware-in-the-loop testbed for non-nuclear testing of microreactor control system automation. A real-time hardware-in-the-loop testbed incorporates the realistic dynamics of physical systems into control system development and testing. The collaborative effort between Oak Ridge National Laboratory (ORNL) and Idaho National Laboratory (INL) resulted in the development of a prototypic microreactor plant-level digital twin that includes the reactor and a balance of plant system. Advanced control strategies were incorporated to demonstrate testing of control automation solutions. The gRPC communication protocol, which was implemented in the hardware-in-the-loop testbed by INL, was coupled to a digital twin model developed using the TRANsient Simulation Framework of Reconfigurable Models (TRANSFORM) library in Modelica. This digital twin simulation was tested with the ViBRANT hardware for realistic feedback and visual representation of control action in real time. A modular Python client structure was developed to manage functional mock-up unit-based simulation and real-time gRPC communication. Hardware-in-the-loop testing indicated that the modeled reactor—a natural-convection, molten-salt coolant loop configuration—responds well to control of drum positioning for modulation of reactor core power, as well as system-level control and downstream demand changes. Ongoing research is focused on integrating additional control algorithms that utilize data from newly included sensors within the MACS hardware testbed, as well as demonstrating and assessing the performance of the different automated control algorithms on multiple additional operational scenarios.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Virtual Space Vector Model Predictive Control for a Seven-Level Hybrid Multilevel Converter

This paper proposes a virtual space vector (VSV) model predictive control (MPC) for a three-phase seven-level (7L) hybrid multilevel converter (HMC), where each phase consists of an active-neutral-point-clamped converter with a floating H-bridge. To achieve the best current tracking, which is the primary goal of the proposed algorithm, a novel geometrical positioning approach is proposed to select the optimal voltage vector among all the realspace vectors and VSVs. Then, all the possible switching sequences that belong to the optimal voltage vector are evaluated to realize the dc capacitor voltage balancing and common-mode voltage reduction. Through an external modulator, the optimal voltage vector can be synthesized by using either one-, three-, or seven-segment switching sequence. Compared with the conventional MPC, the proposed VSV-MPC can reduce not only the computational burden but also the current THD. Both simulation and experimental results obtained on silicon carbide based 7L-HMC prototype are presented to validate the feasibility and effectiveness of the proposed VSVMPC strategy.

42 ENGINEERING↗

A Learning Framework for Control-Oriented Modeling of Buildings

Buildings consume a significant amount of energy worldwide. Several building optimization and control use cases require models of energy consumption which are control oriented, have high predictive capability, imposes minimal data pre-processing requirements, and have the ability to be adapted continuously to account for changing conditions as new data becomes available. Data driven modeling techniques, that have been investigated so far, while promising in the context of buildings, have been unable to simultaneously satisfy all the requirements mentioned above. In this context, deep learning techniques such as Recurrent Neural Networks (RNNs) hold promise, empowered by advanced computational capabilities and big data opportunities. In this paper, we propose a deep learning based methodology for the development of control oriented models for building energy management and test in on data from a real building. Results show that the proposed methodology outperforms other data driven modeling techniques significantly. We perform a detailed analysis of the proposed methodology along dimensions such as topology, sensitivity, and downsampling. Lastly, we conclude by envisioning a building analytics suite empowered by the proposed deep framework, that can drive several use cases related to building energy management.

buildings↗

Model predictive control for integrated control of air-conditioning and mechanical ventilation, lighting and shading systems

Modern buildings are increasingly automated and often equipped with multiple building services (e.g., air-conditioning and mechanical ventilation (ACMV), dynamic shading, dimmable lighting). These systems are conventionally controlled individually without considering their interactions, affecting the building’s overall energy inefficiency and occupant comfort. A model predictive control (MPC) system that features a multi-objective MPC scheme to enable coordinated control of multiple building services for overall optimized energy efficiency, indoor thermal and visual comfort, as well as a hybrid model for predicting indoor visual comfort and lighting power is proposed. The MPC system was implemented in a test facility having two identical, side-by-side experimental cells to facilitate comparison with a building management system (BMS) employing conventional reactive feedback control. The MPC system coordinated the control of the ACMV, dynamic façade and automated dimmable lighting systems in one cell while the BMS controlled the building services in the other cell in a conventional manner. The MPC side achieved 15.1–20.7% electricity consumption reduction, as compared to the BMS side. Simultaneously, the MPC system improved indoor thermal comfort by maintaining the room within the comfortable range (-0.5 < predicted mean vote < 0.5) for 98.3% of the time, up from 91.8% of the time on the BMS side. Visual comfort, measured by indoor daylight glare probability (DGP) and horizontal illuminance level at work plane height, was maintained for the entire test period on the MPC side, improving from having visual comfort for 94.5% and 85.7% of the time, respectively, on the BMS side.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ecosystem Controls on Methylmercury Production by Periphyton Biofilms in a Contaminated Stream: Implications for Predictive Modeling

Periphyton biofilms produce a substantial fraction of the overall monomethylmercury (MMHg) flux in East Fork Poplar Creek, an industrially contaminated, freshwater creek in Oak Ridge, Tennessee. We examined periphyton MMHg production across seasons, locations, and light conditions using mercury stable isotopes. Methylation and demethylation rate potentials (km, trans av and kd, trans av, respectively) were calculated using a transient availability kinetic model. Light exposure and season were significant predictors of km, trans av, with greater values in full light exposure and in the summer. Season, light exposure, and location were significant predictors of kd, trans av, which was highest in dark conditions, in the spring, and at the upstream location. Light exposure was the controlling factor for net MMHg production, with positive production for periphyton grown under full light exposure and net demethylation for periphyton grown in the dark. Ambient MMHg and km, trans av were significantly correlated. Transient availability rate potentials were 15 times higher for km and 9 times higher for kd compared to full availability rate potentials (km, full av and kd, full av) calculated at 1 d. No significant model for the prediction of km, full av or kd, full av could be constructed using light, season, and location. In addition, there were no significant differences among treatments for the full availability km, full av, kd, full av, or net MMHg calculated using the full availability rate potentials. km, full av was not correlated with ambient MMHg concentrations. The present results underscore the importance of applying transient availability kinetics to MMHg production data when estimating MMHg production potential and flux.

Schwartz, Grace E.↗

Model Predictive Control of the Exit Part Temperature for an Austenitization Furnace

Quench hardening is the process of strengthening and hardening ferrous metals and alloys by heating the material to a specific temperature to form austenite (austenitization), followed by rapid cooling (quenching) in water, brine or oil to introduce a hardened phase called martensite. The material is then often tempered to increase toughness, as it may decrease from the quench hardening process. The austenitization process is highly energy-intensive and many of the industrial austenitization furnaces were built and equipped prior to the advent of advanced control strategies and thus use large, sub-optimal amounts of energy. The model computes the energy usage of the furnace and the part temperature profile as a function of time and position within the furnace under temperature feedback control. In this paper, the aforementioned model is used to simulate the furnace for a batch of forty parts under heuristic temperature set points suggested by the operators of the plant. A model predictive control (MPC) system is then developed and deployed to control the the part temperature at the furnace exit thereby preventing the parts from overheating. An energy efficiency gain of 5.3% was obtained under model predictive control compared to operation under heuristic temperature set points tracked by a regulatory control layer.

36 MATERIALS SCIENCE↗

Model Predictive Control for the Operation of Building Cooling Systems

A model-based predictive control (MPC) is designed for optimal thermal energy storage in building cooling systems. We focus on buildings equipped with a water tank used for actively storing cold water produced by a series of chillers. Typically the chillers are operated at night to recharge the storage tank in order to meet the building demands on the following day. In this paper, we build on our previous work, improve the building load model, and present experimental results. The experiments show that MPC can achieve reduction in the central plant electricity cost and improvement of its efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MPCPy: An Open-Source Software Platform for Model Predictive Control in Buildings

Within the last decade, needs for building control systems that reduce cost, energy, or peak demand, and that facilitate building-grid integration, district-energy system optimization, and occupant interaction, while maintaining thermal comfort and indoor air quality, have come about. Current PID and schedule-based control systems are not capable of fulfilling these needs, while Model Predictive Control (MPC) could. Despite the critical role MPC-enabled buildings can play in future energy infrastructures, widespread adoption of MPC within the building industry has yet to occur. To address barriers associated with system setup and configuration, this paper introduces an open-source software platform that emphasizes use of self-tuning adaptive models, usability by non-experts of MPC, and a flexible architecture that enables application across projects.

Blum, David↗

Simplified Two-Stage Model Predictive Control for a Hybrid Multilevel Converter With Floating H-Bridge

This paper proposes a simplified two-stage model predictive control (ST-MPC) for a hybrid multilevel converter, which is an active-neutral-point-clamped converter with floating H-bridge (ANPC-H). The objective of the first stage is to select the voltage vector that has the optimal current tracking performance by using a novel geometrical positioning approach in the complex plane. The second stage selects the best switching state among all the available switching states that belong to the same voltage vector obtained in the first stage, to balance dc capacitor voltages and reduce the common mode voltage. The proposed ST-MPC can dramatically reduce the computational burden and ensure the best current tracking by the two-stage structure, such that the execution time is much shorter compared with the conventional MPC. In addition, the geometrical positioning approach in the first stage is generic and can be applicable for any multilevel converters with N-level output; thus, this ST-MPC can be applied for both sevenand nine-level operation of the hybrid ANPC-H converter under different dc voltage ratios. Both simulation results and experimental results obtained on a silicon carbide hybrid ANPC-H converter prototype validate the feasibility and effectiveness of the proposed ST-MPC strategy.

42 ENGINEERING↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Report for Task 14: Model Verification/Validation Test Plan (Deliverable D10))

This report summarizes the technical progress and validation plan for each of AGGREGATE project modules, and integrated modules. The overall validation plan can be divided into two major parts. Firstly, it provides offline validation results of each module using the IEEE-123 node distribution system with certain modifications to support individual module results verification. The offline validation plan tentatively validated the usability and practicability of developed AGGREGATE tools. Secondly, the realworld test system - Seattle City Light (SCL) test feeder for verifying each module and the integrated modules using GE advanced distribution management system (ADMS) software.

42 ENGINEERING↗

Superconvergence of Online Optimization for Model Predictive Control

We develop a one-Newton-step-per-horizon, online, lag-L, model predictive control (MPC) algorithm for solving discrete-time, equality-constrained, nonlinear dynamic programs. Based on recent sensitivity analysis results for the target problems class, we prove that the approach exhibits a behavior that we call superconvergence; that is, the tracking error with respect to the full horizon solution is not only stable for successive horizon shifts, but also decreases with increasing shift order to a minimum value that decays exponentially in the length of the receding horizon. The key analytical step is the decomposition of the one-step error recursion of our algorithm into algorithmic error and perturbation error. We show that the perturbation error decays exponentially with the lag between two consecutive receding horizons, while the algorithmic error, determined by Newton’s method, achieves quadratic convergence instead. Overall this approach induces our local exponential convergence result in terms of the receding horizon length for suitable values of L. In conclusion, numerical experiments validate our theoretical findings.

97 MATHEMATICS AND COMPUTING↗

Model Predictive Control of A Matrix-Converter Based Solid State Transformer for Utility Grid Interaction

The matrix converter solid state transformer (MC-SST), formed from the back-to-back connection of two three-to-single-phase matrix converters, is studied for use in the interconnection of two ac grids. The matrix converter topology provides a light weight and low volume single-stage bidirectional ac-ac power conversion without the need for a dc link. Thus, the lifetime limitations of dc-bus storage capacitors are avoided. However, space vector modulation of this type of MC-SST requires to compute vectors for each of the two MCs, which must be carefully coordinated to avoid commutation failure. An additional controller is also required to control power exchange between the two ac grids. In this paper, model predictive control (MPC) is proposed for an MC-SST connecting two different ac power grids. The proposed MPC predicts the circuit variables based on the discrete model of MC-SST system and the cost function is formulated so that the optimal switch vector for the next sample period is selected, thereby generating the required grid currents for the SST. Simulation and experimental studies are carried out to demonstrate the effectiveness and simplicity of the proposed MPC for such MC-SST-based grid interfacing systems.

Xue, Yaosuo↗

Koopman Model Predictive Control for Eco-Driving of Automated Vehicles

In this paper, we develop a data-driven process for building a model predictive control (MPC) for eco-driving of automated vehicles. The process involves performing system identification in which the non-linear vehicle dynamics model is approximated by the Koopman operator, a linear predictor of higher state-dimension, in a data-driven framework. This approach allows us to formulate the eco-driving problem in a constrained quadratic program that leads to a computationally fast MPC. The MPC is then implemented as a closed-loop control of an electric vehicle in numerical simulations for demonstration.

autonomous vehicle↗

A Phase-Disposition PWM Enabled Model Predictive Control for a Nine-Level Inner-Interleaved Hybrid Multilevel Converter

This article brings forward a phase-disposition pulse width modulation enabled model predictive control (PDPWM-MPC) for a nine-level inner-interleaved hybrid multilevel converter (9L-IHMC). Firstly, three layers of virtual space vector diagrams (VSVD) are established based on the sign patterns of the original and virtual reference vectors in the abcframe, respectively, to achieve the phase-disposition pulse width modulation (PD-PWM) in a non-independent three-phase way. Then, three adjacent virtual vectors in the third-layer VSVD, together with their optimized duty cycles, are applied to guarantee the optimal current tracking. Finally, through the use of the duty cycle alternation approach, dc-link and floating capacitors voltages are balanced and circulating currents are mitigated as well. The proposed PDPWM-MPC can not only enable the decoupling of the low-and high-frequency stages in the 9L-IHMC, but also reduce both output current ripples and computational burden. In addition, it can achieve a constant equivalent switching frequency and address the disproportion of power losses associated with the PD-PWM. Here, both simulations and experiments on a silicon carbide device-based prototype substantiate the effectiveness of the proposed control strategy.

42 ENGINEERING↗