Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cooling system efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Development and test of two flexible cryogenic heat pipes

Results are presented for a comprehensive test program directed toward determining the physical and thermal performance of two flexible cryogenic heat pipes that can provide a highly efficient thermal link between a detector and a space radiator or other cooling system in spacecraft applications. A 100-200 K high-power heat pipe is tested with methane at 100-140 K while a 15-100 K low-temperature pipe is designed for operation with nitrogen and oxygen and is optimized for oxygen in the range 75-90 K. Parametric performance and design tradeoff studies are carried out to determine the optimum geometry and materials for the container and wicking systems. A spiral multiwrap wick in conjunction with braided bellows appears to be a workable solution to the problem of developing highly flexible heat transport devices for cryogenic applications.

Wright, J. P.↗

Challenges in the development of the orbiter active thermal control subsystem

A number of major challenges were faced in the design and development of the Orbiter Active Thermal Control Subsystem (ATCS). At the system level, the initial challenges were to define an approach that would interface dual Freon coolant loops with multiple coolant loops from other vehicle subsystems with the lowest weight penalty to the Orbiter; and to provide highly responsive vehicle heat rejection throughout all of the Orbiter mission phases. Optimized heat exchangers, representing an advance in the state-of-the-art in heat exchanger design, were developed to transfer heat between the orbiter Freon coolant loops and five other vehicle systems. Flash evaporation was selected as a highly efficient and responsive means for cooling the Orbiter Freon loops during ascent and entry. The Flash Evaporator Subsystem (FES) utilizes cyclic water spray cooling in a chamber maintained at or below the water triple point pressure. A summary of the basic heat transfer research conducted to identify the fundamental heat transfer processes involved in water spray cooling in support of the FES design is given. The high fidelity dynamic analytical model of the FES that was generated to aid in the design of control logic, evaluate performance and simulate ground test and flight anomalies is discussed. A description of the FES and Integrated ATCS testing conducted in the SESL chamber A at NASA-JSC is also presented.

Nason, J. R.↗

C2C Expert Match Technical Assistance: City of Reading, Pennsylvania [Slides]

The City of Reading, located in southeastern Pennsylvania, is the main city in the Greater Reading Area and the county seat of Berks County, with a population of approximately 95,112 as of 2020. Historically a disinvested manufacturing community, it has a poverty rate of around 40%, a housing stock averaging 90 years old, and an owner-occupied housing rate below 40%. In 2019, Reading adopted a resolution to achieve 100% renewable energy by 2050. The city aims to transition residential, small commercial, and small manufacturing sectors to renewable energy for electricity and heating, bypassing natural gas. This C2C Expert Match aimed to improve the energy efficiency and comfort of older rowhomes in Reading, which often rely on home heating oil and lack cooling systems. A representative energy model of a typical rowhome was developed to evaluate retrofit strategies focused on reducing overheating risk, as well as the potential impacts of heat pump installation. Additionally, resources such as case studies and best practices on energy efficiency, thermal resilience, and electrification retrofits were gathered to support the implementation of effective measures in the community.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

HEAT AND MASS TRANSFER IN HUMIDIFYING REGENERATOR FOR A SUB-ATMOSPHERIC HYBRID HEAT ENGINE

Heat and mass transfer processes in advanced modular sub-atmospheric hybrid heat engine have been evaluated for technical and economic feasibility. The presented concept combines fossil fuel energy conversion in a sub-atmospheric air turbine coupled with a reciprocating internal combustion engine to create a hybrid system for power generation. This system can achieve over 65% of net electrical or mechanical power conversion efficiency. The uniqueness of the advanced modular sub-atmospheric hybrid heat engine is in the operating conditions of the air turbine which operates at sub-atmospheric pressure and low temperature and produces power at high efficiency. This is possible due to a unique combination of the system components such as sub-atmospheric air turbine, humidifying air regenerator, and compressor inlet air cooling system. The humidifying air regenerator is the core component of the advanced sub-atmospheric turbine, which makes the turbine ultra-high efficient. It is a regenerative heat-mass exchanger to increase the working fluid (humid air) mass flow rate before the turbine and decrease the mass flow rate after the turbine. It is found that increased heat and mass transfer rate or increased air humidification in humidifying air regenerator would allow the turbine operating at lower temperature and increased efficiency. Optimal heat and mass transfer rates were found for higher efficiency, lower costs, and smaller footprint of the hybrid engine. The results of feasibility study of heat and mass transfer processes in the humidifying air regenerator are presented in this paper.

Heat Engine, Sub-atmospheric Turbine, Humidifying ↗

Modeling and Experiments on a Dedicated Outdoor Air System Using Liquid Desiccant Heat and Mass Exchangers

Liquid desiccants can provide efficient dehumidification but have yet to see widespread adoption. Most systems studied previously use natural gas-combustion to heat and regenerate the desiccant, and a central chiller plant or cooling tower for removing the heat of absorption. Here we present modeling and experimental results on a novel packaged air conditioner integrating liquid-desiccant heat and mass exchangers with a vapor compression cycle. The packaged system does not need cold or hot water from a central plant or cooling tower and is suitable for rooftop unit air conditioners. The system uses the evaporator to cool the liquid desiccant that is absorbing moisture from the air, and the condenser to heat the liquid desiccant to regenerate it. Efficiency is improved by reducing the load on the evaporator for a given supply-air dewpoint. This paper presents the measured dehumidification efficiency for a 10- ton packaged air conditioner, focusing on dehumidifying ventilation air. The paper also presents a numerical model to predict the outlet conditions and dehumidification efficiency, which we compare with the measured data.

air conditioning↗

Technology Development and Field Monitoring in nZEB - US Country report IEA HPT Annex 49 Task 3

The International Energy Agency (IEA) Heat Pumping Technologies (HPT) Annex 49, “Design and Integration of Heat Pumps for Nearly Zero Energy Buildings,” deals with the application of heat pumps (HPs) as a core component of the HVAC system for nearly or net-zero energy buildings. This report covers the Task 3 activities of the US team. Three institutions are involved on the US team and have worked on the following projects. 1) Oak Ridge National Laboratory (ORNL) summarized development activities since the conclusion of IEA HPT Annex 40 for several integrated HP (IHP) systems - electric ground-source IHP and air-source IHP versions and engine-driven AS-IHP version. 2) The University of Maryland partnered with ORNL and Blue Bear Management to develop a personal cooling device called RoCo that can provide personalized conditioned air to occupants in inadequately or unconditioned environments. With RoCo, building facility management can elevate the HVAC thermostat settings without compromising occupants’ thermal comfort. Researchers have found that a 4°F increase in thermostat settings can save 12–30% energy savings. Therefore, RoCo is a promising technology that can help reduce building energy consumption and facilitate achievement of net-zero energy building performance. 3) The National Institute of Standards and Technology (NIST) is working on a field study effort on the NIST Net-Zero Energy Residential Test Facility. Two air-source split-system HPs were installed in a residential, net-zero energy home that was constructed as a laboratory on the NIST campus in Gaithersburg, Maryland. The first HP was a two-stage, 7 kW (2 ton), 15.8 seasonal energy efficiency ratio (SEER), 9.05 heating seasonal performance factor (HSPF) conventionally ducted system; the second HP was a variable-speed, 10.6 kW (3 ton), 14 SEER, 8.35 HSPF, high-velocity ducted system. These two systems operated side by side, using separate supply ducts and a common return duct, on a weekly alternating schedule to condition the home that was operated with very consistent simulated thermal loads. The team wanted to determine whether the high-velocity system could provide comparable energy-use efficiency to the conventional system. The results of this study showed that it did meet the required loads and had slightly greater efficiency; the average cooling coefficient of performance (COP) was (0.40 ± 0.11) higher, and the average heating COP was statistically equal. A new firmware was provided at the end of the heating season that greatly improved the performance of the high-velocity system; its average heating COP went from (1.8 ± 0.9) to (2.5 ± 1.1) at a 95% confidence level. The new firmware heating COP averaged (1.05 ± 0.23) higher than the old firmware over the same outdoor temperatures. The defrost performance is very different for these two systems, yet they consumed equivalent energy per HDD. The conventional system uses a timed-initiate, temperature-terminate algorithm with auxiliary electric resistive heating, whereas the high-velocity system uses calculated evaporator parameters with a hot-gas bypass before a full reverse-cycle defrost with no supplementary resistive heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy characteristics of multi-chiller load distribution algorithms in a large office building

Here, this study evaluates the energy efficiency of multi-chiller systems in large office buildings, focusing on their optimization across various climate zones as defined by ASHRAE. Using EnergyPlus for simulations, the research examines five different load distribution algorithms in multi-chiller systems that range from one to ten chillers, aiming to understand their effectiveness in 15 distinct climate zones. The primary objectives of the study include identifying the energy efficiency of multi-chiller systems in each climate zone, determining the appropriate number of chillers for each zone, and evaluating the performance of the load distribution algorithms. Based on the U.S. Department of Energy’s commercial building model, the results suggest that multi-chiller systems can significantly reduce cooling energy consumption in various climates. Among the algorithms evaluated, the Sequential Uniform Part Load Ratio (SUPLR) algorithm demonstrates notable efficiency, especially in the 4A climate zone (Baltimore), where it achieves substantial energy savings. Applying the SUPLR algorithm in a multi-chiller setup with four chillers in this zone leads to an estimated 24.5 % reduction in energy usage, equivalent to 183 MW annually. The research indicates that a range of 3 to 5 chillers is typically optimal for most climate zones. In-depth analysis in the 4A climate zone highlights the importance of minimizing operation hours at low Part Load Ratios (PLR) to ensure that chillers operate at a high Coefficient of Performance (COP). This strategy underscores the potential of well-designed multi-chiller systems to reduce cooling energy demand, particularly in climates with transitional seasons. This study provides an overview of the energy-saving potential of multi-chiller systems, applicable across a variety of climatic scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Retrofit Energy Analysis and Central Thermal modeling (REACT) v1.0

REACT is a website designed to simplify the analysis and decision-making process for retrofitting existing central plant heating and cooling systems with advanced heat pump technologies. The tool evaluates the technical and economic viability of replacing traditional boilers with various options including water-to-water or air-to-water heat pumps, which can provide efficient and lower-cost heating and cooling. It allows users to compare current central plant configurations with retrofit scenarios, assessing energy consumption, life-cycle costs, and environmental impact. Retrofitting traditional boiler and chiller systems with water-to-water or air-to-water heat pumps can significantly reduce energy consumption and lower lifecycle costs. The REACT provides: User-Friendly Tools: A user friendly web interface for quick, intuitive analysis accessible to non-experts. Advanced Modeling: A Python-powered engine for detailed parametric studies, optimization, and research applications. Comprehensive Analysis: Lifecycle cost evaluation, energy consumption modeling, and environmental impact assessment. Visual Insights: A variety of plots to visualize system performance and design trade-offs. The engine for the website (REACT) bases on several Python libraries, and the website will be hosted on an ETA server.

Kim, Donghun [Lawrence Berkeley National Laborator↗

Exploratory study of several advanced nuclear-MHD power plant systems.

In order for efficient multimegawatt closed cycle nuclear-MHD systems to become practical, long-life gas cooled reactors with exit temperatures of about 2500 K or higher must be developed. Four types of nuclear reactors which have the potential of achieving this goal are the NERVA-type solid core reactor, the colloid core (rotating fluidized bed) reactor, the 'light bulb' gas core reactor, and the 'coaxial flow' gas core reactor. Research programs aimed at developing these reactors have progressed rapidly in recent years so that prototype power reactors could be operating by 1980. Three types of power plant systems which use these reactors have been analyzed to determine the operating characteristics, critical parameters and performance of these power plants. Overall thermal efficiencies as high as 80% are projected, using an MHD turbine-compressor cycle with steam bottoming, and slightly lower efficiencies are projected for an MHD motor-compressor cycle.

Williams, J. R.↗

District EnErgy Planner (DEEP) v2

The District EnErgy Planner - DEEP is an Mixed Integer Linear Programming (MILP) optimization software tool to solve district energy system, technology configuration, operation strategies, and energy retail business schemes. DEEP takes user input energy demand on heating, cooling and electricity demand. Energy loss through pipeline is calculated for heating and cooling from central plants. The optimal system configuration to minimize the district energy system life cycle cost or minimize CO2 emission is calculated based on energy balance equations and various constraints. The recent update on DEEP include a feature of waste heat utilization energy balance based optimization to take into accounts of different temperature bands of heat into account to maximize system efficiency. Another feature is to optimize district energy retail by provide optimal pricing scheme for heating, cooling and electricity to end users to incorporate district to grid demand response.

Feng, Wei↗

Development and field demonstration of residential air source integrated heat pump using a three-stage compressor

To promote decarbonization and all electrification at residential sectors, it is necessary to use air source heat pumps (ASHPs) to replace natural gas for space heating and water heating. ASHPs are widely utilized for residential space cooling, heating, and water heating due to their simplicity and cost-effectiveness. However, their performance can be compromised in cold climates, where they may experience reduced heating capacity. A multi-functional heat pump, using a single compressor, to meet all home space conditioning and water heating demands, is an emerging technology. To address this limitation, we have developed and demonstrated an air source integrated heat pump to fulfill comprehensive home comfort requirements. This system employs a three-stage compressor and a single set of heat exchangers and valves, optimizing functionality while minimizing costs. The performance of the developed system was rigorously evaluated in both laboratory and field settings. In laboratory conditions, the system achieved a Seasonal Energy Efficiency Ratio of 17.0 (average COP of 4.98) and a Heating Seasonal Performance Factor of 11.0 (3.22). Additionally, in its most efficient operational mode—combining space cooling and water heating—the unit attained a total energy efficiency exceeding 7.0 seasonal COP in the field and could heat a 189-liter tank of water in just 25 min. The field study corroborated the laboratory findings, validating the system’s performance in real-world conditions. Here, this integrated heat pump represents an ideal solution for decarbonizing homes in northern climates by providing efficient space heating and water heating, thereby replacing the need for natural gas.

Integrated heat pump↗

Air quality and comfort constrained energy efficient operation of multi-zone buildings

Maintaining indoor air quality (IAQ) through effective ventilation is essential for the well-being and productivity of building occupants. Control strategies aimed at improving the efficiency of heating, ventilation and air conditioning (HVAC) systems must jointly determine ventilation and heating and cooling processes. Here, in this paper, we study the problem of minimizing the energy consumption of the HVAC system in a multi-zone building, while meeting thermal comfort and IAQ requirements. We first perform a steady state analysis of the zonal carbon dioxide (CO 2 ) concentration and the temperature dynamics. The resulting expressions are convex in the zonal mass flow rates and zonal temperatures. Guided by the steady state solutions for meeting the thermal comfort constraints, we develop two control policies for improving the energy efficiency of building HVAC systems while jointly satisfying indoor temperature and IAQ constraints. We compare the performance of our proposed approaches with those of multiple baseline approaches which implement separate regimes for controlling zonal temperature and IAQ for a typical work-day in a multi-zone campus building. We have evaluated the performance of our proposed approaches under varying levels of flexibility in zonal temperatures. We have shown that zonal temperature flexibility can result in energy savings up to 32% (for the same control strategies) as compared to the case where no such flexibility is permitted. Our proposed approaches were seen to offer potential savings of nearly 29% compared to the baseline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tm,Ho:YLF laser end-pumped by a semiconductor diode laser array

An Ho:YLF crystal including Tm as sensitizers for the activator Ho, is optically pumped with a semiconductor diode laser array to generate 2.1 micron radiation with a pump power to output power of efficiency as high as 68 percent. The prior-art dual sensitizer system of Er and Tm requires cooling, such as by LN2, but by using Tm alone and decreasing the concentrations of Tm and Ho, and decreasing the length of the laser rod to about 1 cm, it has been demonstrated that laser operation can be obtained from a temperature of 77 K with an efficiency as high as 68 percent up to ambient room temperature with an efficiency at that temperature as high as 9 percent.

Hemmati, Hamid↗

Thermoeconomic analysis of a multigeneration system using waste heat from a triple power cycle

Multigeneration systems represent an appealing concept, due to their multiple benefits compared to standalone systems, which has motivated researchers to develop different types of multigeneration systems for several applications. Considering their significance, in this study, a novel multigeneration is proposed that uses the waste heat of a thermodynamically efficient triple power cycle with a 100 MWe capacity. The proposed system, which can generate power, freshwater, cooling, and domestic hot water concurrently, is evaluated using detailed thermodynamic and economic analyses. The triple cycle includes a simple Brayton cycle coupled with a supercritical carbon dioxide recompression cycle and a high-temperature organic Rankine cycle. The waste energy of the recompression and organic Rankine cycles is recovered by a half effect absorption chiller, a multi-effect distillation unit, and two heat exchangers. The results show that for an optimized triple cycle, up to 1,804 kW cooling and 8,472 m 3 /day of hot water can be generated from the hot supercritical carbon dioxide stream with a levelized cost of cooling and hot water of 0.0362/ton-hr and $0.6823/MWth, respectively. The integration of a multi-effect distillation unit with 7 effects can generate 4,167 m 3 /day freshwater with a levelized cost of water of $1.142/m 3 . Finally, the proposed multigeneration system offers a very promising application and a number of benefits such as a generating multiple useful products with no adverse effect on the thermodynamic efficiency of the triple power cycle.

Thermoeconomic analysis↗

Fundamental mode excitation via Joule–Thomson light expansion in nonlinear optical lattices

Under linear conditions, power injected from a single waveguide into a multi-core fiber array results in multimode propagation, progressively diminishing the spatial coherence of light. In this work, we introduce a comprehensive approach to mitigate this coherence loss by means of a nonlinear thermodynamic Joule–Thomson expansion. By leveraging the tools of optical thermodynamics, we demonstrate that as light undergoes a sudden transition from a small to a larger nonlinear optical array, it can abruptly drop its optical temperature to near-zero values. During this cooling process, light irreversibly flows into the system's fundamental mode with very high efficiency, synchronizing all elements of the lattice with the input port. We show that this nonlinear effect is highly predictable even in systems of arbitrary geometry and shape and can be controlled precisely by the initial conditions at the input of the array. In particular, for a single injection point, the reduction in optical temperature can be directly determined by the total power, irrespective of the input location.

Pyrialakos, Georgios G. (ORCID:0000000286129694)↗

MSR Fuel Salt Qualification Methodology

This report documents the continuing activities at Oak Ridge National Laboratory (ORNL) in support of the US Nuclear Regulatory Commission (NRC) efforts to develop an efficient, appropriate process for liquid fuel salt system qualification. Fuel qualification for salt-cooled molten salt reactors (MSRs) is part of the ongoing coated particle fuel qualification effort. Fuel qualification is a process which provides high confidence that physical and chemical behavior of fuel is sufficiently understood so that it can be adequately modeled for both normal and accident conditions, reflecting the role of the fuel design in the overall safety of the facility. Uncertainties are defined so that calculated fission product releases include the appropriate margins to ensure conservative calculation of radiological dose consequences. The initial phase of ORNL’s activities is documented in ORNL/LTR-2018/1045 Molten Salt Reactor Fuel Qualification Considerations and Challenges.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Impact of Thermochromic Coatings on Thermal Management for Human Spacecraft Applications

Thermochromic variable emittance coatings (VECs) allow for passive, dynamic thermal management of space vehicles due to their temperature dependent optical properties. Ideally, a thermochromic material should exhibit low mid-IR emissivity for lower temperatures and switch to high mid-IR emissivity for higher temperatures; one promising material that demonstrates these characteristics is Lanthanum Strontium Manganite (LSM). The transition temperatures of LSM are dependent on the Lanthanum-to-Strontium ratio x, La1-xSrxMnO3. La0.8Sr0.2MnO3, which has an emittance of 0.5 for < 270 K, then a linear increase in emittance to 0.8 over an increase of 70 K where it will saturate at ~340K, is commonly utilized but this is tunable by changing the Sr concentration. The tunability of the transition temperature range of LSM motivates a need to understand the optimal thermal transition range for human spacecraft. Additionally, LSM has high solar absorptance and to combat this issue the VEC will be micropatterned on top of a highly solar reflective layer of Barium Sulfate (BaSO4). Consequently, this work will elucidate the tradeoffs between solar absorptance and variable emittance for this technology since the micropattern adversely couples the solar absorptance to the mid-IR emittance. This work develops a computational model using Thermal Desktop to study the utility of VECs on human spacecraft, such as Orion, subjected to mission phases such as lunar transit and Gateway docking. The model considers both external heat loads, from solar irradiation and planetary IR, as well as vehicle heat loads, from avionics and crew, as an input into the body mounted thermochromic radiators. There are several design targets for VECs, i.e. achieving the largest change in emittance, finding the optimal temperature range for the transition, and achieving the highest emittance in the high temperature phase. This work prioritizes these design targets for LSM to achieve the optimal heat rejection for a human spacecraft. The VECs are compared with static emittance coatings and the efficiency gains are quantified. Thermochromic VECs will ultimately lead to simplifications of active cooling systems which synergistically correlates to mass reduction and less energy consumption for space vehicles.

Joseph Peoples↗

An Active Broad Area Cooling Model of a Cryogenic Propellant Tank with a Single Stage Reverse Turbo-Brayton Cycle Cryocooler

As focus shifts towards long-duration space exploration missions, an increased interest in active thermal control of cryogenic propellants to achieve zero boil-off of cryogens has emerged. An active thermal control concept of considerable merit is the integration of a broad area cooling system for a cryogenic propellant tank with a combined cryocooler and circulator system that can be used to reduce or even eliminate liquid cryogen boil-off. One prospective cryocooler and circulator combination is the reverse turbo-Brayton cycle cryocooler. This system is unique in that it has the ability to both cool and circulate the coolant gas efficiently in the same loop as the broad area cooling lines, allowing for a single cooling gas loop, with the primary heat rejection occurring by way of a radiator and/or aftercooler. Currently few modeling tools exist that can size and characterize an integrated reverse turbo-Brayton cycle cryocooler in combination with a broad area cooling design. This paper addresses efforts to create such a tool to assist in gaining a broader understanding of these systems, and investigate their performance in potential space missions. The model uses conventional engineering and thermodynamic relationships to predict the preliminary design parameters, including input power requirements, pressure drops, flow rate, cycle performance, cooling lift, broad area cooler line sizing, and component operating temperatures and pressures given the cooling load operating temperature, heat rejection temperature, compressor inlet pressure, compressor rotational speed, and cryogenic tank geometry. In addition, the model allows for the preliminary design analysis of the broad area cooling tubing, to determine the effect of tube sizing on the reverse turbo-Brayton cycle system performance. At the time this paper was written, the model was verified to match existing theoretical documentation within a reasonable margin. While further experimental data is needed for full validation, this tool has already made significant steps towards giving a clearer understanding of the performance of a reverse turbo-Brayton cycle cryocooler integrated with broad area cooling technology for zero boil-off active thermal control.

Guzik, Monica C.↗