Search NASA⌕ Search

SEARCH · Search NASA

Results for “Count”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

High-count rate effects in event processing for XRISM/ Resolve X-ray microcalorimeter: I. Ground test

The spectroscopic performance of an X-ray microcalorimeter is compromised at high count rates. We utilize the Resolve X-ray microcalorimeter onboard the XRISM satellite to examine the effects observed during high-count rate measurements and propose modeling approaches to mitigate them. We specifically address the following instrumental effects that impact performance: CPU limit, pile-up, and untriggered electrical cross-talk. Experimental data at high count rates were acquired during ground testing using the flight model instrument and a calibration X-ray source. In the experiment, data processing not limited by the performance of the onboard CPU was run in parallel, which cannot be done in orbit. This makes it possible to access the data degradation caused by limited CPU performance. We use these data to develop models that allow for a more accurate estimation of the aforementioned effects. To illustrate the application of these models in observation planning, we present a simulated observation of GX 13+1. Understanding and addressing these issues is crucial to enhancing the reliability and precision of X-ray spectroscopy in situations characterized by elevated count rates.

47 OTHER INSTRUMENTATION↗

SU-E-I-77: A Noise Reduction Technique for Energy-Resolved Photon-Counting Detectors

Purpose: Finding the optimal energy threshold setting for an energy-resolved photon-counting detector has an important impact on the maximization of contrast-to-noise-ratio (CNR). We introduce a noise reduction method to enhance CNR by reducing the noise in each energy bin without altering the average gray levels in the projection and image domains. Methods: We simulated a four bin energy-resolved photon-counting detector based on Si with a 10 mm depth of interaction. TASMIP algorithm was used to simulate a spectrum of 65 kVp with 2.7 mm Al filter. A 13 mm PMMA phantom with hydroxyapatite and iodine at different concentrations (100, 200 and 300 mg/ml for HA, and 2, 4, and 8 mg/ml for Iodine) was used. Projection-based and Image-based energy weighting methods were used to generate weighted images. A reference low noise image was used for noise reduction purposes. A Gaussian-like weighting function which computes the similarity between pixels of interest was calculated from the reference image and implemented on a pixel by pixel basis for the noisy images. Results: CNR improvement compared to different methods (Charge-Integrated, Photon-Counting and Energy-Weighting) and after noise reduction was highly task-dependent. The CNR improvement with respect to the Charge-Integrated CNR for hydroxyapatite and iodine were 1.8 and 1.5, respectively. In each of the energy bins, the noise was reduced by approximately factor of two without altering their respective average gray levels. Conclusion: The proposed noise reduction technique for energy-resolved photon-counting detectors can significantly reduce image noise. This technique can be used as a compliment to the current energy-weighting methods in CNR optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-F-18A-05: An X-Ray Fluorescence Technique for Energy Calibration of Photon-Counting Detectors

Purpose: To investigate the feasibility of energy response calibration of a Si strip photon-counting detector by using the x-ray fluorescence technique. Methods: X-ray fluorescence was generated by using a pencil beam from a tungsten anode x-ray tube with 2 mm Al filtration. Spectra were acquired at 90° from the primary beam direction with an energy-resolved photon-counting detector based on Si strips. The distances from the source to target and the target to detector were approximately 19 and 11 cm, respectively. Four different materials, containing Ag, I, Ba, and Gd, were placed in small plastic aliquots with a diameter of approximately 0.7 cm for x-ray fluorescence measurements. Linear regression analysis was performed to derive the gain and offset values for the correlation between the measured fluorescence peak center and the known energies for materials. The energy resolution was derived from the full width at half maximum (FWHM) of the fluorescence peaks. In addition, the angular dependence of the recorded fluorescence spectra was studied at 30°, 60°, and 120°. Results: Strong fluorescence signals of all four target materials were recorded with the investigated geometry for the Si strip detector. The recorded pulse height was calibrated with respect to photon energy and the gain and offset values were calculated to be 7.0 mV/keV and −69.3 mV, respectively. Negligible variation in energy calibration was observed among the four energy thresholds. The variation among different pixels was estimated to be approximately 1 keV. The energy resolution of the detector was estimated to be 7.9% within the investigated energy range. Conclusion: The performance of a spectral imaging system using energy-resolved photon-counting detectors is very dependent on the energy calibration of the detector. The proposed x-ray fluorescence technique provides an accurate and efficient way to calibrate the energy response of a photon-counting detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of energy response for photon-counting detectors using x-ray fluorescence

Purpose: To investigate the feasibility of characterizing a Si strip photon-counting detector using x-ray fluorescence. Methods: X-ray fluorescence was generated by using a pencil beam from a tungsten anode x-ray tube with 2 mm Al filtration. Spectra were acquired at 90° from the primary beam direction with an energy-resolved photon-counting detector based on an edge illuminated Si strip detector. The distances from the source to target and the target to detector were approximately 19 and 11 cm, respectively. Four different materials, containing silver (Ag), iodine (I), barium (Ba), and gadolinium (Gd), were placed in small plastic containers with a diameter of approximately 0.7 cm for x-ray fluorescence measurements. Linear regression analysis was performed to derive the gain and offset values for the correlation between the measured fluorescence peak center and the known fluorescence energies. The energy resolutions and charge-sharing fractions were also obtained from analytical fittings of the recorded fluorescence spectra. An analytical model, which employed four parameters that can be determined from the fluorescence calibration, was used to estimate the detector response function. Results: Strong fluorescence signals of all four target materials were recorded with the investigated geometry for the Si strip detector. The average gain and offset of all pixels for detector energy calibration were determined to be 6.95 mV/keV and −66.33 mV, respectively. The detector’s energy resolution remained at approximately 2.7 keV for low energies, and increased slightly at 45 keV. The average charge-sharing fraction was estimated to be 36% within the investigated energy range of 20–45 keV. The simulated detector output based on the proposed response function agreed well with the experimental measurement. Conclusions: The performance of a spectral imaging system using energy-resolved photon-counting detectors is very dependent on the energy calibration of the detector. The proposed x-ray fluorescence technique offers an accurate and efficient way to calibrate the energy response of a photon-counting detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

{sup 90}Y -PET imaging: Exploring limitations and accuracy under conditions of low counts and high random fraction

Purpose: {sup 90}Y -positron emission tomography (PET) imaging is becoming a recognized modality for postinfusion quantitative assessment following radioembolization therapy. However, the extremely low counts and high random fraction associated with {sup 90}Y -PET may significantly impair both qualitative and quantitative results. The aim of this work was to study image quality and noise level in relation to the quantification and bias performance of two types of Siemens PET scanners when imaging {sup 90}Y and to compare experimental results with clinical data from two types of commercially available {sup 90}Y microspheres. Methods: Data were acquired on both Siemens Biograph TruePoint [non-time-of-flight (TOF)] and Biograph microcomputed tomography (mCT) (TOF) PET/CT scanners. The study was conducted in three phases. The first aimed to assess quantification and bias for different reconstruction methods according to random fraction and number of true counts in the scan. The NEMA 1994 PET phantom was filled with water with one cylindrical insert left empty (air) and the other filled with a solution of {sup 90}Y . The phantom was scanned for 60 min in the PET/CT scanner every one or two days. The second phase used the NEMA 2001 PET phantom to derive noise and image quality metrics. The spheres and the background were filled with a {sup 90}Y solution in an 8:1 contrast ratio and four 30 min acquisitions were performed over a one week period. Finally, 32 patient data (8 treated with Therasphere{sup ®} and 24 with SIR-Spheres{sup ®}) were retrospectively reconstructed and activity in the whole field of view and the liver was compared to theoretical injected activity. Results: The contribution of both bremsstrahlung and LSO trues was found to be negligible, allowing data to be decay corrected to obtain correct quantification. In general, the recovered activity for all reconstruction methods was stable over the range studied, with a small bias appearing at extremely high random fraction and low counts for iterative algorithms. Point spread function (PSF) correction and TOF reconstruction in general reduce background variability and noise and increase recovered concentration. Results for patient data indicated a good correlation between the expected and PET reconstructed activities. A linear relationship between the expected and the measured activities in the organ of interest was observed for all reconstruction method used: a linearity coefficient of 0.89 ± 0.05 for the Biograph mCT and 0.81 ± 0.05 for the Biograph TruePoint. Conclusions: Due to the low counts and high random fraction, accurate image quantification of {sup 90}Y during selective internal radionuclide therapy is affected by random coincidence estimation, scatter correction, and any positivity constraint of the algorithm. Nevertheless, phantom and patient studies showed that the impact of number of true and random coincidences on quantitative results was found to be limited as long as ordinary Poisson ordered subsets expectation maximization reconstruction algorithms with random smoothing are used. Adding PSF correction and TOF information to the reconstruction greatly improves the image quality in terms of bias, variability, noise reduction, and detectability. On the patient studies, the total activity in the field of view is in general accurately measured by Biograph mCT and slightly overestimated by the Biograph TruePoint.

60 APPLIED LIFE SCIENCES↗

NoC-enabled Software/Hardware Co-Design Framework for Accelerating k-mer Counting

Counting k-mers (substrings of fixed length k) in DNA and protein sequences generate non-uniform and irregular memory access patterns. Processing-in-Memory (PIM) architectures have potential to significantly reduce the overheads associated with such frequent and irregular memory accesses. However, existing k-mer counting algorithms are not designed to exploit the advantages of PIM architectures. Furthermore, owing to thermal constraints, the allowable power budget is limited in conventional PIM designs. Moreover, k-mer counting generates long-range, non-uniform traffic patterns which needs to be handled by an efficient Network-on-Chip (NoC). In this paper, we present an NoC-enabled hardware/software co-design framework to implement high-performance k-mer counting. The proposed architecture enables more computational power, efficient communication between cores/memory – all without creating a thermal bottleneck. The software component overcomes the I/O bottleneck, aids in NoC design and exposes more in-memory opportunities to exploit in PIM. Experimental results show that the proposed architecture outperforms a state-of-the-art software implementation using Hybrid Memory Cube (HMC), by up to 7.14X, while allowing significantly higher power budget.

Joardar, Biresh K.↗

HeadCount (Automated & Anonymous In-Vehicle Occupancy Detection and Counting) [SWR 19-14]

The HeadCount software is filling a transportation information gap by counting how many people take each rideshare ride. The transportation industry is undergoing rapid transformation. Personally-driven trips via privately owned vehicles are being replaced by commercial services such as ride-hailing and car-sharing. In the same time, municipalities have increasingly expressed interest in the movement of people, rather than just vehicles. However, there is a lack of technology to collect vehicle occupancy data to quantify the movement of people at a large scale. Existing means of counting vehicle occupants have proven insufficient for a variety of reasons. Most notably, these include complicated installations (outfitted seatbelt sensors with dedicated wiring), reliance on technology adoption (cell phone signal counting), driver participation (manual survey entry), etc. These limitations have hindered all interested stakeholders: vehicle fleet owners continue to be unaware of the number of serviced customers, researchers still rely on hand written survey information, and municipalities have no reliable technology to enforce occupancy-based measures (HOV lanes, passenger-based tolls, etc.). Therefore, an automated in-vehicle occupancy detection and counting system was designed to collect vehicle occupancy data with minimal human effort involved. This technology is the first of its kind with low cost, simple installation, and high accuracy. In fact, the device correctly identified the number of occupants in 99.7% of cases. Occupancy detection relates to many applications, ranging from energy intensity quantification and incentivizing high occupancy vehicle to fleet management and optimization.

Moniot, Matthew↗

THE HAWAII SCUBA-2 LENSING CLUSTER SURVEY: NUMBER COUNTS AND SUBMILLIMETER FLUX RATIOS

We present deep number counts at 450 and 850 μ m using the SCUBA-2 camera on the James Clerk Maxwell Telescope. We combine data for six lensing cluster fields and three blank fields to measure the counts over a wide flux range at each wavelength. Thanks to the lensing magnification, our measurements extend to fluxes fainter than 1 mJy and 0.2 mJy at 450 μ m and 850 μ m, respectively. Our combined data highly constrain the faint end of the number counts. Integrating our counts shows that the majority of the extragalactic background light (EBL) at each wavelength is contributed by faint sources with L {sub IR} < 10{sup 12} L {sub ⊙}, corresponding to luminous infrared galaxies (LIRGs) or normal galaxies. By comparing our result with the 500 μ m stacking of K -selected sources from the literature, we conclude that the K -selected LIRGs and normal galaxies still cannot fully account for the EBL that originates from sources with L {sub IR} < 10{sup 12} L {sub ⊙}. This suggests that many faint submillimeter galaxies may not be included in the UV star formation history. We also explore the submillimeter flux ratio between the two bands for our 450 μ m and 850 μ m selected sources. At 850 μ m, we find a clear relation between the flux ratio and the observed flux. This relation can be explained by a redshift evolution, where galaxies at higher redshifts have higher luminosities and star formation rates. In contrast, at 450 μ m, we do not see a clear relation between the flux ratio and the observed flux.

79 ASTRONOMY AND ASTROPHYSICS↗

One-count memory circuit prevents machine mode interaction

One-count memory logic circuit used with electromechanical counter-printer machines operates in either count or print mode. The circuit advances the counter when the machine is in the count mode and provides storage for the count pulse when the machine is in the print mode.

De~forest, B.↗

Predicted star counts in selected fields and photometric bands Applications to galactic structure, the disk luminosity function, and the detection of a massive halo

Tables are presented of predicted star counts in 17 selected directions on the sky as a function of apparent B, V, R, and I magnitudes and absolute visual magnitudes calculated from the Bahcall-Soneira Galaxy model. It is noted that eight of the fields were selected ab initio for their usefulness in determining from star counts either parameters of galactic structure, the faint end of the disk luminosity function, or the detection of a massive stellar halo. Star counts in specified fields to m sub I = 19 mag are able to reveal the faint end of the disk luminosity function down to the end of the hydrogen-burning main sequence. It is thought that star counts at high galactic latitudes to m sub I = 22 mag should reveal the stellar constituents of a massive halo if they are massive enough to be on the hydrogen-burning main sequence.

Bahcall, J. N.↗

Operation of a microchannel plate counting system in a mass spectrometer

A multiplier detector system has been developed as part of a mass spectrometer in an ion counting mode. During its operation ions striking a microchannel plate release pulses of electrons which are accelerated to a phosphor layer. The resulting flash of light is carried by a fiber-optic bundle to a photodiode array. The detector simultaneously counts ions throughout a mass spectrum covering more than 30 amu. It extends the mass spectrometer's operation toward low count rates for trace gas analysis. Each mass peak can be independently measured at count rates between 0.1 and 1000 counts/s. Higher rates on a few peaks do not blind the entire detector. The detector's capabilities have been demonstrated by measuring Kr and Xe isotopes in air at natural abundances. The mass spectrometer, detector, and readout electronics are sufficiently compact to permit use in a balloon-borne experiment.

Murphy, D. M.↗

The Shane-Wirtanen counts - Systematics and two-point correlation function

Residual errors in the Selder et al. (SSGP) map which caused a break in both the correlation factor (CF) and the filamentary appearance of the Shane-Wirtanen map are examined. These errors, causing a residual rms fluctuation of 11 percent in the SSGP-corrected counts and a systematic rms offset of 8 percent in the mean count per plate, can be attributed to counting pattern and plate vignetting. Techniques for CF reconstruction in catalogs affected by plate-related systematic biases are examined, and it is concluded that accurate restoration may not be possible. Surveys designed to measure the CF at the depth of the SW counts on a scale of 2.5 deg, must have systematic errors of less than or about 0.04 mag.

De Lapparent, V.↗

Star counts and galactic structure

Star counts are discussed as an aid in studies of galactic structure. Iterative computations using a method-of-color-bins to match numerical models with observational data are described. The star counts provide bounds for the luminosity function and the color-magnitude diagram and allow spheroid normalization in a copycat Galaxy model which posits a galaxy with a Population I disk and a Population II spheroid. Good agreement has been obtained between star counts predicted by the model and observed distributions, including color and magnitude ranges and direction. Modifications being considered for the model include consideration of the halo, a galactic bulge and a thick disk. Several galactic structural features which have yet to be modeled and which may be tractable to the copycat model corrected with star counts are identified.

Bahcall, John N.↗

Photon counting modules using RCA silicon avalanche photodiodes

Avalanche photodiodes (APD) are excellent small area, solid state detectors for photon counting. Performance possibilities include: photon detection efficiency in excess of 50 percent; wavelength response from 400 to 1000 nm; count rate to 10 (exp 7) counts per sec; afterpulsing at negligible levels; timing resolution better than 1 ns. Unfortunately, these performance levels are not simultaneously available in a single detector amplifier configuration. By considering theoretical performance predictions and previous and new measurements of APD performance, the anticipated performance of a range of proposed APD-based photon counting modules is derived.

Lightstone, Alexander W.↗

Comparative morphology of configurations with reduced part count derived from the octahedral-tetrahedral truss

Morphology (the study of structure and form) of the octahedral-tetrahedral (octet) truss is described. Both the geometry and symmetry of the octet truss are considered. Morphological techniques based on symmetry operations are presented which enable the derivation of reduced-part-count truss configurations from the octet truss by removing struts and nodes. These techniques are unique because their Morphological origination and they allow for the systematic generation and analysis of a large variety of structures. Methods for easily determining the part count and redundancy of infinite truss configurations are presented. Nine examples of truss configurations obtained by applying the derivation techniques are considered. These configurations are structurally stable while at the same time exhibiting significant reductions in part count. Some practical and analytical considerations, such as structural performance, regarding the example reduced-part-count truss geometries are briefly discussed.

Lalvani, Haresh↗

Generation and analysis of reduced-part-count truss geometries for space-based applications

A technique for deriving truss structures with reduced part count from the octahedral-tetrahedral (octet) truss by removal of struts and nodes is described. The technique is based on an understanding of the geometry and symmetry of the octet truss. Six example reduced-part-count structures are analyzed and compared with the parent octet truss with regard to part count, redundancy, mass, and free-free fundamental frequency. Part count reductions of 12 to 37 percent, mass reductions of 7 to 33 percent, and fundamental frequency reductions of 18 to 30 percent are demonstrated. Increases in strut cross-sectional area and truss depth are considered for the purpose of increasing the stiffness of the reduced structures.

Collins, Timothy J.↗

An Optical Bit-Counting Algorithm

This paper addresses the omnipresent problem of counting bits - an operation discussed since the very early stages of the establishing of computer science. The need for a quick bit-counting method acquires a special significance with the proliferation of search engines on the Internet. It arises in several other computer applications. This is especially true in information retrieval in which an array of binary vectors is used to represent a characteristic function (CF) of a set of qualified documents. The number of "I"s in the CF equals the cardinality of the set. The process of repeated evaluations of this cardinality is a pivotal point in choosing a rational strategy for deciding whether to constrain or broaden the search criteria to ensure selection of the desired items. Another need for bit-counting occurs when trying to determine the differences between given files, (images or text), in terms of the Hamming distance. An Exclusive OR operation applied to a pair of files results in a binary vector array of mismatches that must be counted.

Mack, Marilyn↗

The GLOBE Earth Day 2004 Contrail Count-a-Thon

Early in 2004 the GLOBE Science team suggested a contrail count activity to celebrate Earth Day 2004, which was held this year on April 22nd in the United States and some other countries around the world. The GLOBE contrail team embraced this idea and developed a simplified data collection sheet for this special project. Information about the event was shared through the GLOBE site, UCAR and NASA press releases, the NASA portal (http://www.nasa.gov) and the CERES S'COOL Project (http://scool.larc.nasa.gov). On Earth Day, about 120 observations were received through the GLOBE Contrail Count-a-Thon website, about 70 contrail observations were received through regular GLOBE data reporting, and 19 contrail observations were received through regular S'COOL data reporting. Only observations between 11:00 and 13:00 local time were included in the Count-a-Thon. The event was reported in the Boulder Daily Camera beforehand and in the Oregon Register-Guard after the fact. It was also reported on National Public Radio s Day-to-Day show; whose host even submitted an observation. This poster discusses the Count-a-Thon experience and reports the results.

Chambers, Lin H.↗