Search NASA⌕ Search

SEARCH · Search NASA

Results for “DIRECTIONAL DRILLING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Helium measurements of pore-fluids obtained from SAFOD drillcore

{sup 4}He accumulated in fluids is a well established geochemical tracer used to study crustal fluid dynamics. Direct fluid samples are not always collectable; therefore, a method to extract rare gases from matrix fluids of whole rocks by diffusion has been adapted. Helium was measured on matrix fluids extracted from sandstones and mudstones recovered during the San Andreas Fault Observatory at Depth (SAFOD) drilling in California, USA. Samples were typically collected as subcores or from drillcore fragments. Helium concentration and isotope ratios were measured 4-6 times on each sample, and indicate a bulk {sup 4}He diffusion coefficient of 3.5 {+-} 1.3 x 10{sup -8} cm{sup 2}s{sup -1} at 21 C, compared to previously published diffusion coefficients of 1.2 x 10{sup -18} cm{sup 2}s{sup -1} (21 C) to 3.0 x 10{sup -15} cm{sup 2}s{sup -1} (150 C) in the sands and clays. Correcting the diffusion coefficient of {sup 4}He{sub water} for matrix porosity ({approx}3%) and tortuosity ({approx}6-13) produces effective diffusion coefficients of 1 x 10{sup -8} cm{sup 2}s{sup -1} (21 C) and 1 x 10{sup -7} (120 C), effectively isolating pore fluid {sup 4}He from the {sup 4}He contained in the rock matrix. Model calculations indicate that <6% of helium initially dissolved in pore fluids was lost during the sampling process. Complete and quantitative extraction of the pore fluids provide minimum in situ porosity values for sandstones 2.8 {+-} 0.4% (SD, n=4) and mudstones 3.1 {+-} 0.8% (SD, n=4).

54 ENVIRONMENTAL SCIENCES↗

Advanced Seismic While Drilling System

A breakthrough has been discovered for controlling seismic sources to generate selectable low frequencies. Conventional seismic sources, including sparkers, rotary mechanical, hydraulic, air guns, and explosives, by their very nature produce high-frequencies. This is counter to the need for long signal transmission through rock. The patent pending SeismicPULSER{trademark} methodology has been developed for controlling otherwise high-frequency seismic sources to generate selectable low-frequency peak spectra applicable to many seismic applications. Specifically, we have demonstrated the application of a low-frequency sparker source which can be incorporated into a drill bit for Drill Bit Seismic While Drilling (SWD). To create the methodology of a controllable low-frequency sparker seismic source, it was necessary to learn how to maximize sparker efficiencies to couple to, and transmit through, rock with the study of sparker designs and mechanisms for (a) coupling the sparker-generated gas bubble expansion and contraction to the rock, (b) the effects of fluid properties and dynamics, (c) linear and non-linear acoustics, and (d) imparted force directionality. After extensive seismic modeling, the design of high-efficiency sparkers, laboratory high frequency sparker testing, and field tests were performed at the University of Texas Devine seismic test site. The conclusion of the field test was that extremely high power levels would be required to have the range required for deep, 15,000+ ft, high-temperature, high-pressure (HTHP) wells. Thereafter, more modeling and laboratory testing led to the discovery of a method to control a sparker that could generate low frequencies required for deep wells. The low frequency sparker was successfully tested at the Department of Energy Rocky Mountain Oilfield Test Center (DOE RMOTC) field test site in Casper, Wyoming. An 8-in diameter by 26-ft long SeismicPULSER{trademark} drill string tool was designed and manufactured by TII. An APS Turbine Alternator powered the SeismicPULSER{trademark} to produce two Hz frequency peak signals repeated every 20 seconds. Since the ION Geophysical, Inc. (ION) seismic survey surface recording system was designed to detect a minimum downhole signal of three Hz, successful performance was confirmed with a 5.3 Hz recording with the pumps running. The two Hz signal generated by the sparker was modulated with the 3.3 Hz signal produced by the mud pumps to create an intense 5.3 Hz peak frequency signal. The low frequency sparker source is ultimately capable of generating selectable peak frequencies of 1 to 40 Hz with high-frequency spectra content to 10 kHz. The lower frequencies and, perhaps, low-frequency sweeps, are needed to achieve sufficient range and resolution for realtime imaging in deep (15,000 ft+), high-temperature (150 C) wells for (a) geosteering, (b) accurate seismic hole depth, (c) accurate pore pressure determinations ahead of the bit, (d) near wellbore diagnostics with a downhole receiver and wired drill pipe, and (e) reservoir model verification. Furthermore, the pressure of the sparker bubble will disintegrate rock resulting in an increased overall rates of penetration. Other applications for the SeismicPULSER{trademark} technology are to deploy a low-frequency source for greater range on a wireline for Reverse Vertical Seismic Profiling (RVSP) and Cross-Well Tomography. Commercialization of the technology is being undertaken by first contacting stakeholders to define the value proposition for rig site services utilizing SeismicPULSER{trademark} technologies. Stakeholders include national oil companies, independent oil companies, independents, service companies, and commercial investors. Service companies will introduce a new Drill Bit SWD service for deep HTHP wells. Collaboration will be encouraged between stakeholders in the form of joint industry projects to develop prototype tools and initial field trials. No barriers have been identified for developing, utilizing, and exploiting the low-frequency SeismicPULSER{trademark} source in a variety of applications. Risks will be minimized since Drill Bit SWD will not interfere with the drilling operation, and can be performed in a relatively quiet environment when the pumps are turned off. The new source must be integrated with other Measurement While Drilling (MWD) tools. To date, each of the oil companies and service companies contacted have shown interest in participating in the commercialization of the low-frequency SeismicPULSER{trademark} source. A technical paper has been accepted for presentation at the 2009 Offshore Technology Conference (OTC) in a Society of Exploration Geologists/American Association of Petroleum Geophysicists (SEG/AAPG) technical session.

02 PETROLEUM↗

SU-C-19A-06: A Robust and Affordable Table Indexing Approach for Total Lymphoid Irradiation Treatment

Purpose: Total lymphoid irradiation (TLI) is conventionally delivered through the dosimetric matching of mantle, spleen, and pelvis fields, necessitating multiple isocenters delivered through a combination of couch shifts and sliding of patients relative to the couch rendering the technique susceptible to shifting errors. To address this challenge, a novel technique for the couch indexing of TLI treatments is developed and evaluated through a multi-patient pilot trial. Methods: An immobilization device was designed consisting of a movable indexed slide board with an Exact Lok-Bar drilled into it. A Timo headrests were used fixate the head of the patient relative to the slide board. For the Varian Exact Couch™, the immobilization board was connected to the H3 notch to avoid the metal infrastructure of the couch for the delivery of the mantle and spleen fields. For tall patients the required shift for the pelvis isocenter reaches the shifting limit and the board was slid from H3 to H4 (a fixed distance of 14 cm). A total 22 patients were stratified in two groups of 11, one consisting of the conventional setup, and one group with the proposed immobilization technique. Results: The standard deviations (SD) of the couch positions in lateral, longitudinal, and vertical directions for 10 fractions for each patient in both groups were calculated. In the non-indexed group, the positioning SD ranged from 0.9 to 4.7 cm. Using our device, the positioning SD was reduced to a range of 0.2 to 0.9 cm, with the longitudinal direction showing the largest improvement. Conclusion: Matched field TLI remains error prone to geometrical misses. The feasibility of full indexing TLI treatments was validated and shown to result in a significant reduction of positioning errors.

60 APPLIED LIFE SCIENCES↗

Poster — Thur Eve — 57: Evaluation of laryngeal mucosal dose with conventional linac and TomoTherapy

The purpose of this study was to examine whether or not underdosing occurs in the mucosal layer during treatment of glottis cancer. A larynx phantom was produced and regions at risk of recurrence due to suspected underdosing were identified and wells drilled into the phantom for flush placement of TLDs. Seven interest points were chosen. CT simulation was completed prior to the wells being drilled, and again afterwards with the TLD locations indicated using BBs. Treatment plans created for this investigation included: 3DCRT using Elekta-XiO (n=9) and VMAT created using Elekta-Monaco (n=9), both delivered on an Elekta linac; standard TomoTherapy plan (n=11) and a directionally blocked TomoTherapy plan to approximate a 3D-conformal approach (n=5). Imaging dose during TomoTherapy deliveries was accounted for. The average TLD result at each interest point was compared to the planned value using a paired t-test. There was no significant difference between the planned and measured 3DCRT dose (268.9 vs. 267.0 cGy, respectively; p>0.05). Similarly, the planned and measured TomoTherapy treatment did not show any significant differences (271.7 vs 269.7 cGy; p>0.05). In the blocked TomoTherapy plan, significant overdosing was seen (274.5 vs 294.9 cGy; p<0.05) and underdosing was not seen in the VMAT treatment (303.5 vs 321.8 cGy; p>0.05). Further investigation is ongoing to ensure appropriate normalization of results and to investigate the overdosing noted with the blocked TomoTherapy plan. Results from this study suggest that significant underdosing does not occur in the conventional treatment of early glottic cancer using 6MV photons.

60 APPLIED LIFE SCIENCES↗

Modeling of well drilling heating on crude oil using microwave

As the world’s oil reserves are dwindling, some researchers have been prompted to make a breakthrough to further improve the efficiency of exploration and production. One of the technologies used is heating the crude oil. This paper presents the modeling results of heat treatment on crude oil using microwave energy. Modeling is conducted by assuming that the diameter of the well is 11,16 cm, the heat source is applied on the surface of the well, and the cut-off frequency in the air and on crude oil are 1,56 GHz. and 0.91 GHz, respectively. The energy generated by the microwave radiation is converted into heat energy which is absorbed by the crude oil. Consequently, this energy increases the temperature of crude oil through a heat transfer mechanism. The results obtained showed that the temperature of crude oil is about 200°C at a depth of 62.5cm, and at a distance of 3 cm from the center of the well. Temperature along the well follows an exponential function, which is from the center of the well in the direction radially outward from the cylinder axis. It has been observed that the temperature decreases as measured from the well surface along the cylinder.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Method and system for advancement of a borehole using a high power laser

There is provided a system, apparatus and methods for the laser drilling of a borehole in the earth. There is further provided with in the systems a means for delivering high power laser energy down a deep borehole, while maintaining the high power to advance such boreholes deep into the earth and at highly efficient advancement rates, a laser bottom hole assembly, and fluid directing techniques and assemblies for removing the displaced material from the borehole.

47 OTHER INSTRUMENTATION↗

Additive Manufacturing: The Rise of a Technology and the Need for Quality Control and Inspection Techniques

Additive manufacturing (AM) technology, also known as three-dimensional (3D) printing, rapid prototyping (RP), or solid free forms (SFF), was developed back in the early 1980s. The technology was quickly commercialized in the late 1980s, and since then, the technology has been widely used in different applications at several industrial sectors. AM offers distinct advantages from traditional, subtractive manufacturing techniques. Traditional subtractive manufacturing techniques, including milling, drilling, and turning, are techniques that start with a large block of stock material, which is then subtracted from until the final desired product is reached, leaving much of the initial block as wasted scrap. In the AM process, the part is constructed by depositing material layer by layer in the Z-direction until the final product is produced, leaving little to no waste. The process starts with a computer-aided design (CAD) model that gets sliced into individual layers using software that generates instructions, known as G-code, which are sent to the AM machine. Here, this process allows complex geometry construction that traditional methods would have diffi-culty accomplishing or fail completely. In some cases, a secondary finishing process is needed such as polishing, sintering, curing, sanding, powder removal, or painting.

36 MATERIALS SCIENCE↗

Predevelopment Water-Level Contours for Aquifers in the Rainier Mesa and Shoshone Mountain area of the Nevada Test Site, Nye County, Nevada

Contaminants introduced into the subsurface of the Nevada Test Site at Rainier Mesa and Shoshone Mountain by underground nuclear testing are of concern to the U.S. Department of Energy and regulators responsible for protecting human health and safety. Although contaminants were introduced into low-permeability rocks above the regional flow system, the potential for contaminant movement away from the underground test areas and into the accessible environment is greatest by ground-water transport. The primary hydrologic control on this transport is evaluated and examined through a series of contour maps developed to represent the water-level distribution within each of the major aquifers underlying the area. Aquifers were identified and their extents delineated by merging and analyzing multiple hydrostratigraphic framework models developed by other investigators from existing geologic information. The contoured water-level distribution in each major aquifer was developed from a detailed evaluation and assessment of available water-level measurements. Multiple spreadsheets that accompany this report provide pertinent water-level and geologic data by well or drill hole. Aquifers are mapped, presented, and discussed in general terms as being one of three aquifer types—volcanic aquifer, upper carbonate aquifer, or lower carbonate aquifer. Each of these aquifer types was subdivided and mapped as independent continuous and isolated aquifers, based on the continuity of its component rock. Ground-water flow directions, as related to the transport of test-generated contaminants, were developed from water-level contours and are presented and discussed for each of the continuous aquifers. Contoured water-level altitudes vary across the study area and range from more than 5,000 feet in the volcanic aquifer beneath a recharge area in the northern part of the study area to less than 2,450 feet in the lower carbonate aquifer in the southern part of the study area. Variations in water-level altitudes within any single continuous aquifer range from a few hundred feet in a lower carbonate aquifer to just more than 1,100 feet in a volcanic aquifer. Flow directions throughout the study area are dominantly southward with minor eastward or westward deviations. Primary exceptions are westward flow in the northern part of the volcanic aquifer and eastward flow in the eastern part of the lower carbonate aquifer. Northward flow in the upper and lower carbonate aquifers in the northern part of the study area is possible but cannot be substantiated because data are lacking. Interflow between continuous aquifers is evaluated and mapped to define major flow paths. These flow paths delineate tributary flow systems, which converge to form the regional ground-water flow system. The implications of these tributary flow paths in controlling transport away from the underground test areas at Rainier Mesa and Shoshone Mountain are discussed. The obvious data gaps contributing to uncertainties in the delineation of aquifers and development of water-level contours are identified and evaluated.

58 GEOSCIENCES↗

Geothermal Deep Direct-Use for Low-Carbon Heating: A Case Study at Cornell University

Cornell University is developing a geothermal deep direct-use system to provide reliable, low carbon, and cost-competitive heating for its main campus in Ithaca, New York. This geothermal system, also referred to as Earth Source Heat, would provide the majority of the campus heating load and represents a key pillar for the university to become carbon neutral by 2035. Over the last 10 years, numerous desktop, seismic, and geophysical studies have been undertaken at Cornell to characterize the local subsurface, predict long-term reservoir performance, design the integration into the existing district heating network, and estimate capital and levelized costs. Recently, the university received funding for drilling an observatory well to obtain in-situ subsurface data (e.g., reservoir temperatures, pressures, fluid chemistry, stress field), significantly lowering subsurface uncertainty and de-risking the project. Drilling of the test well is planned for fall 2021. This paper provides an overview and status of the project, including a summary of past studies and a description of the proposed well and planned testing activities.

Cornell University↗

Implementation of the Iterative Proportion Fitting Algorithm for Geostatistical Facies Modeling

In geostatistics, most stochastic algorithm for simulation of categorical variables such as facies or rock types require a conditional probability distribution. The multivariate probability distribution of all the grouped locations including the unsampled location permits calculation of the conditional probability directly based on its definition. In this article, the iterative proportion fitting (IPF) algorithm is implemented to infer this multivariate probability. Using the IPF algorithm, the multivariate probability is obtained by iterative modification to an initial estimated multivariate probability using lower order bivariate probabilities as constraints. The imposed bivariate marginal probabilities are inferred from profiles along drill holes or wells. In the IPF process, a sparse matrix is used to calculate the marginal probabilities from the multivariate probability, which makes the iterative fitting more tractable and practical. This algorithm can be extended to higher order marginal probability constraints as used in multiple point statistics. The theoretical framework is developed and illustrated with estimation and simulation example.

58 GEOSCIENCES↗

Gas hydrate characterization from a 3D seismic dataset in the deepwater eastern Gulf of Mexico

Principal component analysis of spectral decomposition results combined with amplitude and frequency seismic attributes derived from 3D seismic data are used for the identification and characterization of gas hydrate deposits in the deepwater eastern Gulf of Mexico. In the central deepwater Gulf of Mexico (GoM), logging while drilling LWD data provided insight to the amplitude response of gas hydrate saturation in sands, which could be used to characterize complex gas hydrate deposits in other sandy deposits. In this study, a large 3D seismic data set from equivalent and distal Plio Pleistocene sandy channel deposits in the deepwater eastern Gulf of Mexico is screened for direct hydrocarbon indicators for gas hydrate saturated sands.

gas hydrate↗

Alaska North Slope 2018 Hydrate-01 Stratigraphic Test Well: Technical Results

The Hydrate-01 Stratigraphic Test Well was drilled in December 2018 to confirm that a seismically-identified location within the western Prudhoe Bay Unit might be suitable for extended-duration scientific production testing. The well featured the acquisition of a full suite of logging-while-drilling data, collection of side-wall pressure cores, and installation of distributed temperature and distributed acoustic sensor (DTS, DAS) fiber-optic cables. Evaluation of the logging-while-drilling data confirms gas hydrate is present at high saturation in two target sands of high reservoir quality. Acquired logs and samples enable critical petrophysical information to be compiled for input into production models. The well tested two primary targets: the deeper Unit B is highly favorable due to optimal reservoir temperature and minimal observed risk for direct communication with permeable, hydrate-free water-bearing zones. The shallower Unit D provides a secondary target and opportunity to

Boswell, Ray↗

Gas Hydrate Characterization from a 3D Seismic Dataset in the Eastern Deepwater Gulf of Mexico

The presence of a gas hydrate petroleum system and seismic attributes derived from 3D seismic data are used for the identification and characterization of gas hydrate deposits in the deepwater eastern Gulf of Mexico. In the central deepwater Gulf of Mexico (GoM), logging while drilling (LWD) data provided insight to the amplitude response of gas hydrate saturation in sands, which could be used to characterize complex gas hydrate deposits in other sandy deposits. In this study, a large 3D seismic data set from equivalent and distal Plio-Pleistocene sandy channel deposits in the deepwater eastern Gulf of Mexico is screened for direct hydrocarbon indicators for gas hydrate saturated sands.

gas hydrate↗

Multiphase reacting flow modeling of singlet oxygen generators for chemical oxygen iodine lasers.

Singlet oxygen generators are multiphase flow chemical reactors used to generate energetic oxygen to be used as a fuel for chemical oxygen iodine lasers. In this paper, a theoretical model of the generator is presented along with its solutions over ranges of parameter space and oxygen maximizing optimizations. The singlet oxygen generator (SOG) is a low-pressure, multiphase flow chemical reactor that is used to produce molecular oxygen in an electronically excited state, i.e. singlet delta oxygen. The primary product of the reactor, the energetic oxygen, is used in a stage immediately succeeding the SOG to dissociate and energize iodine. The gas mixture including the iodine is accelerated to a supersonic speed and lased. Thus the SOG is the fuel generator for the chemical oxygen iodine laser (COIL). The COIL has important application for both military purposes--it was developed by the US Air Force in the 1970s--and, as the infrared beam is readily absorbed by metals, industrial cutting and drilling. The SOG appears in various configurations, but the one in focus here is a crossflow droplet generator SOG. A gas consisting of molecular chlorine and a diluent, usually helium, is pumped through a roughly rectangular channel. An aqueous solution of hydrogen peroxide and potassium hydroxide is pumped through small holes into the channel and perpendicular to the direction of the gas flow. So doing causes the solution to become aerosolized. Dissociation of the potassium hydroxide draws a proton from the hydrogen peroxide generating an HO{sub 2} radical in the liquid. Chlorine diffuses into the liquid and reacts with the HO{sub 2} ion producing the singlet delta oxygen; some of the oxygen diffuses back into the gas phase. The focus of this work is to generate a predictive multiphase flow model of the SOG in order to optimize its design. The equations solved are the so-called Eulerian-Eulerian form of the multiphase flow Navier-Stokes equations wherein one set of the equations represents the gas phase and another equation set of size m represents the liquid phase. In this case, m is representative of the division of the liquid phase into distinct representations of the various droplet sizes distributed in the reactor. A stabilized Galerkin formulation is used to solve the equation set on a computer. The set of equations is large. There are five equations representing the gas phase: continuity, vector momentum, heat. There are 5m representing the liquid phase: number density, vector momentum, heat. Four mass transfer equations represent the gas phase constituents and there are m advection diffusion equations representing the HO{sub 2} ion concentration in the liquid phase. Thus we are taking advantage of and developing algorithms to harness the power of large parallel computing architectures to solve the steady-state form of these equations numerous times so as to explore the large parameter space of the equations via continuation methods and to maximize the generation of singlet delta oxygen via optimization methods. Presented here will be the set of equations that are solved and the methods we are using to solve them. Solutions of the equations will be presented along with solution paths representing varying aerosol loading-the ratio of liquid to gas mass flow rates-and simple optimizations centered around maximizing the oxygen production and minimizing the amount of entrained liquid in the gas exit stream. Gas-entrained liquid is important to minimize as it can destroy the lenses and mirrors present in the lasing cavity.

42 ENGINEERING↗

Pressure Spike in The LBNF Absorber Core s Gun Drilled Cooling Channel from an Accident Beam Pulse

he LBNF absorber consists of thirteen 6061-T6 aluminum core blocks. The core blocks are water cooled with de-ionized (DI) water which becomes radioactive during beam operations. The cooling water flows through gun-drilled channels in the core blocks. The cooling water is supplied by the LBNF absorber radioactive water (RAW) cooling system which is designed as per ASME B31.3 normal fluid service. An uninhibited beam accident pulse striking the water channels was identified as a credible accident scenario. In this study, it is assumed that the beam pulse hits the absorber directly without interacting with any of the other upstream beamline components. The beam parameters used for the LBNF beam are 120 GeV, 2.4 MW with a 1.2 s cycle time. The accident pulse lasts for 10 µs. The maximum energy is deposited in the 3rd aluminum core block. For the sake of simplicity, it is assumed that the accident pulse strikes the 1 in. ID water channel directly. The analysis here simulates the pressure rise in the water during and after the beam pulse and its effects on the aluminum piping components that deliver water to the core blocks. The weld strengths as determined by the Load and Resistance Factor Design (LRDF) and the Allowable Strength Design (ASD) are compared to the forces generated in the weld owing to the pressure spike. A transient structural analysis was used to determine the equivalent membrane, peak, and bending stresses and they were compared to allowable limits.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pressure Spike in The LBNF Absorber Core s Gun Drilled Cooling Channel from an Accident Beam Pulse

The LBNF Absorber consists of thirteen 6061-T6 aluminum core blocks. The core blocks are water cooled with de-ionized (DI) water which becomes radioactive during beam operations. The cooling water flows through gun-drilled channels in the core blocks. The cooling water is supplied by the LBNF Absorber Radioactive Water (RAW) cooling system which is designed as per ASME B31.3 Normal Fluid Service [1]. An uninhibited beam accident pulse striking the water channels was identified as a credible accident scenario. In this study, it is assumed that the beam pulse hits the Absorber directly without interacting with any of the other upstream beamline components. The beam parameters used for the LBNF beam are 120 GeV, 2.4 MW with a 1.2 s cycle time. The accident pulse lasts for 10 μs. The maximum energy is deposited in the 3rd aluminum core block. For the sake of simplicity, it is assumed that the accident pulse strikes the 1 in. ID water channel directly. The analysis here simulates the pressure rise in the water during and after the beam pulse and its effects on the aluminum piping components that deliver water to the core blocks. The weld strengths as determined by the Load and Resistance Factor Design (LRDF) and the Allowable Strength Design (ASD) are compared to the forces generated in the weld owing to the pressure spike. A transient structural analysis was used to determine the equivalent membrane, peak, and bending stresses and they were com-pared to allowable limits.

43 PARTICLE ACCELERATORS↗

Fully Automated Laser Ablation Liquid Capture Sample Analysis using NanoElectrospray Ionization Mass Spectrometry

RATIONALE: Laser ablation provides for the possibility of sampling a large variety of surfaces with high spatial resolution. This type of sampling when employed in conjunction with liquid capture followed by nanoelectrospray ionization provides the opportunity for sensitive and prolonged interrogation of samples by mass spectrometry as well as the ability to analyze surfaces not amenable to direct liquid extraction. METHODS: A fully automated, reflection geometry, laser ablation liquid capture spot sampling system was achieved by incorporating appropriate laser fiber optics and a focusing lens into a commercially available, liquid extraction surface analysis (LESA ) ready Advion TriVersa NanoMate system. RESULTS: Under optimized conditions about 10% of laser ablated material could be captured in a droplet positioned vertically over the ablation region using the NanoMate robot controlled pipette. The sampling spot size area with this laser ablation liquid capture surface analysis (LA/LCSA) mode of operation (typically about 120 m x 160 m) was approximately 50 times smaller than that achievable by direct liquid extraction using LESA (ca. 1 mm diameter liquid extraction spot). The set-up was successfully applied for the analysis of ink on glass and paper as well as the endogenous components in Alstroemeria Yellow King flower petals. In a second mode of operation with a comparable sampling spot size, termed laser ablation/LESA , the laser system was used to drill through, penetrate, or otherwise expose material beneath a solvent resistant surface. Once drilled, LESA was effective in sampling soluble material exposed at that location on the surface. CONCLUSIONS: Incorporating the capability for different laser ablation liquid capture spot sampling modes of operation into a LESA ready Advion TriVersa NanoMate enhanced the spot sampling spatial resolution of this device and broadened the surface types amenable to analysis to include absorbent and solvent resistant materials.

alstroemeria↗

Laser drilling and machining enhancement using gated CW and short pulsed lasers

The present disclosure relates to a laser system for processing a material. The system may make use of a laser configured to intermittently generate a first laser pulse of a first duration and a first average power, at a spot on a surface of the material being processed, and a second laser pulse having a second duration and a second peak power. The second duration may be shorter than the first duration by a factor of at least 100, and directed at the spot. The second laser pulse is generated after the first laser pulse is generated. The first laser pulse is used to heat the spot on the surface of the material, while the second laser pulse induces a melt motion and material ejection of molten material from the melt pool.

Ly, Sonny S.↗