Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data compression (Computer science)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Cosmological constraints from a joint DESI DR1 Full-Shape and DR2 BAO

We present a cosmological analysis combining full-shape (FS) clustering measurements from the Dark Energy Spectroscopic Instrument (DESI) DR1 with baryon acoustic oscillation (BAO) measurements from DESI DR2. To achieve a robust combination that accounts for the correlation between the two data releases, we employ the ShapeFit compression method and estimate the joint covariance using EZmocks. This compressed approach inherently mitigates the prior volume effects that have previously dominated Bayesian constraints from DESI data with minimal external priors. Consequently, we obtain — for the first time within a Bayesian framework — reliable DESI-only constraints on extensions to ΛCDM using only a Big Bang Nucleosynthesis prior on the baryon density and a wide prior on the spectral index. In flat ΛCDM, we find Ω m = 0.3035 ± 0.0085, h = 0.6876 ± 0.0059, and σ 8 = 0.822 ± 0.034. For the w 0 w a CDM dynamical dark energy model, we measure w 0 = -0.49 ± 0.25 and w a = -1.52 ± 0.77, improving constraints by ∼ 30% relative to the analogous DR1 measurement and reducing the discrepancy with ΛCDM to 1.4σ when compared to BAO only analyses. We also report competitive limits on the sum of neutrino masses and spatial curvature. This work demonstrates that the ShapeFit compression provides a prior-robust and computationally efficient pathway to constrain beyond-ΛCDM physics with large-scale structure.

baryon acoustic oscillations↗

Accelerated acquisition of tagged MRI for cardiac motion correction in simultaneous PET-MR: Phantom and patient studies

Purpose: Degradation of image quality caused by cardiac and respiratory motions hampers the diagnostic quality of cardiac PET. It has been shown that improved diagnostic accuracy of myocardial defect can be achieved by tagged MR (tMR) based PET motion correction using simultaneous PET-MR. However, one major hurdle for the adoption of tMR-based PET motion correction in the PET-MR routine is the long acquisition time needed for the collection of fully sampled tMR data. In this work, the authors propose an accelerated tMR acquisition strategy using parallel imaging and/or compressed sensing and assess the impact on the tMR-based motion corrected PET using phantom and patient data. Methods: Fully sampled tMR data were acquired simultaneously with PET list-mode data on two simultaneous PET-MR scanners for a cardiac phantom and a patient. Parallel imaging and compressed sensing were retrospectively performed by GRAPPA and kt-FOCUSS algorithms with various acceleration factors. Motion fields were estimated using nonrigid B-spline image registration from both the accelerated and fully sampled tMR images. The motion fields were incorporated into a motion corrected ordered subset expectation maximization reconstruction algorithm with motion-dependent attenuation correction. Results: Although tMR acceleration introduced image artifacts into the tMR images for both phantom and patient data, motion corrected PET images yielded similar image quality as those obtained using the fully sampled tMR images for low to moderate acceleration factors (<4). Quantitative analysis of myocardial defect contrast over ten independent noise realizations showed similar results. It was further observed that although the image quality of the motion corrected PET images deteriorates for high acceleration factors, the images were still superior to the images reconstructed without motion correction. Conclusions: Accelerated tMR images obtained with more than 4 times acceleration can still provide relatively accurate motion fields and yield tMR-based motion corrected PET images with similar image quality as those reconstructed using fully sampled tMR data. The reduction of tMR acquisition time makes it more compatible with routine clinical cardiac PET-MR studies.

60 APPLIED LIFE SCIENCES↗

A sparse reconstruction method for the estimation of multi-resolution emission fields via atmospheric inversion

Atmospheric inversions are frequently used to estimate fluxes of atmospheric greenhouse gases (e.g., biospheric CO 2 flux fields) at Earth's surface. These inversions typically assume that flux departures from a prior model are spatially smoothly varying, which are then modeled using a multi-variate Gaussian. When the field being estimated is spatially rough, multi-variate Gaussian models are difficult to construct and a wavelet-based field model may be more suitable. Unfortunately, such models are very high dimensional and are most conveniently used when the estimation method can simultaneously perform data-driven model simplification (removal of model parameters that cannot be reliably estimated) and fitting. Such sparse reconstruction methods are typically not used in atmospheric inversions. In this work, we devise a sparse reconstruction method, and illustrate it in an idealized atmospheric inversion problem for the estimation of fossil fuel CO 2 (ffCO 2 ) emissions in the lower 48 states of the USA. Our new method is based on stagewise orthogonal matching pursuit (StOMP), a method used to reconstruct compressively sensed images. Our adaptations bestow three properties to the sparse reconstruction procedure which are useful in atmospheric inversions. We have modified StOMP to incorporate prior information on the emission field being estimated and to enforce non-negativity on the estimated field. Finally, though based on wavelets, our method allows for the estimation of fields in non-rectangular geometries, e.g., emission fields inside geographical and political boundaries. Our idealized inversions use a recently developed multi-resolution (i.e., wavelet-based) random field model developed for ffCO 2 emissions and synthetic observations of ffCO 2 concentrations from a limited set of measurement sites. We find that our method for limiting the estimated field within an irregularly shaped region is about a factor of 10 faster than conventional approaches. It also reduces the overall computational cost by a factor of 2. Further, the sparse reconstruction scheme imposes non-negativity without introducing strong nonlinearities, such as those introduced by employing log-transformed fields, and thus reaps the benefits of simplicity and computational speed that are characteristic of linear inverse problems.

54 ENVIRONMENTAL SCIENCES↗

Characterization and Modeling of Hot Deformation Behavior of a Copper-Bearing High-Strength Low-Carbon Steel Microalloyed with Nb

This study investigates hot deformation behavior of a newly developed Cu-bearing high-strength low-carbon steel microalloyed with Nb (Nb-HSLC). A computational method based on experimental data was employed to design the chemical composition of the alloy. Compression tests were carried out in the temperature range of 850-1100 °C as well as strain rates of 0.001-10 s{sup −1} using BAHR Dil 805 A/D thermo-analyzer equipment. The Arrhenius-type constitutive equations were used to model the hot working behavior of the designed steel. Effects of friction and temperature rise during deformation were corrected to obtain the actual stresses. The results showed that the peak flow stress was increased with increasing Zener–Hollomon parameter. The obtained flow curves at strain rates lower than 0.1 s{sup −1} and temperatures above 950 °C represented the typical dynamic recrystallization (DRX) behavior, while the flow curves at temperatures lower than 950 °C at all strain rates were associated with continuous strain hardening. This feature is in good agreement with the precipitation temperature range of Nb(C, N) particles, i.e., 800-1000 °C. Moreover, the flow curves showed the serrations during hot deformation at strain rates of 0.001 and 0.01 s{sup −1}, indicating that the dynamic strain aging (DSA) phenomenon occurred at low strain rates. The best fit between “peak stress” and “deformation conditions” was obtained by a hyperbolic sine-type equation (R{sup 2} = 0.993). Therefore, the average activation energy was determined as 348 kJ mol{sup −1}. The agreement between the achieved model and experimental flow data was verified using the results of additional tests at a strain rate of 5 s{sup −1}. The maximum difference between the measured and predicted “peak stresses” was calculated as 5 Mpa.

36 MATERIALS SCIENCE↗

Nuclear data uncertainty propagation and modeling uncertainty impact evaluation in neutronics core simulation

Uncertainty analysis is a critical requirement in reactor simulation as it is used to quantify the reliability of best-estimate calculation. A comprehensive uncertainty analysis should characterize all sources of uncertainties in a computationally-feasible and scientifically-defendable manner. Here we employ a well-established reduced order modeling (ROM) based uncertainty quantification methodology to propagate uncertainties throughout neutronic calculations. ROM relies on recent advances in randomized data mining techniques applied to large data streams. In our proposed implementation, the nuclear data uncertainties are first propagated from multi-group level through lattice physics calculation to generate few-group parameter uncertainties, described using a vector of mean values and a covariance matrix. Employing an ROM-based compression of the covariance matrix, the few-group uncertainties are then propagated through downstream core simulation in a computationally efficient manner. This straightforward approach, albeit efficient as compared to brute force forward and/or adjoint-based methods, often employs a number of assumptions that have been unquestioned in the literature of neutronic uncertainty analysis. This manuscript argues that these assumptions could introduce another source of uncertainty referred to as modeling uncertainties, whose magnitude needs to be quantified in tandem with nuclear data uncertainties. Thus, our primary goal is to explore the interactions between these two uncertainty sources in order to assess whether modeling uncertainties have an impact on parameter uncertainties. To explore this endeavor, the impact of a number of modeling assumptions on core attributes uncertainties is quantified. The study employs a CANDU reactor model, with Serpent and NEWT as lattice physics solvers and NESTLE-C as core simulator. The modeling assumptions investigated include those related with the uncertainty propagation method employed, e.g., deterministic vs. stochastic, the few-group energy structure employed to represent the cross-sections, the resonance treatment in lattice physics calculation, the reference values for the cross-section, and the number of samples employed to render ROM compression. Results indicate that some of the modeling assumptions could have a non-negligible impact on the core responses propagated uncertainties, highlighting the need for a more comprehensive approach to combine parameter and modeling uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TH-CD-207A-04: Optimized Respiratory Gating for Abnormal Breathers in Pancreatic SBRT

Purpose: Pancreatic SBRT is uniquely challenging due to both the erratic/unstable motion of the pancreas and the close proximity of the radiosensitive small bowel. Respiratory gating can mitigate this effect, but the irregularity of motion severely affects traditional phase-based gating. The purpose of this study was to analyze real-time motion data of pancreatic tumors to optimize the efficacy and accuracy of respiratory gating, with the overall goal of enabling dose escalated pancreatic SBRT. Methods: Fifteen pancreatic SBRT patients received 30–33 Gy in 5 fractions on a Varian TrueBeam STx unit. Abdominal compression was used to reduce the amplitude of tumor motion, and daily cone-beam computed tomography (CBCT) scans were acquired prior to each treatment for target localization purposes. For this study, breathing data (phase and amplitude) were collected during each CBCT scan using Varian’s Real-Time Position Management system. An in-house template matching technique was used to track the superior-inferior motion of implanted fiducial markers in CBCT projection images. Using tumor motion and breathing data, phase-based or amplitude-based respiratory gating was simulated for all 75 fractions, targeting either end-exhalation or end-inhalation phases of breathing. Results: For the average patient, gating at end-exhalation offered the best reductions in effective motion for equal duty cycles. However, optimal central phase angle varied widely (range: 0–92%, mean±SD: 49±12%), and phase-based gating windows typically associated with end-exhalation (i.e., “30–70%”) were rarely ideal. Amplitude-based gating significantly outperformed phase-based gating, with average effective ranges for amplitude-based gating 25% lower than phase-based gating ranges (as much as 73% lower). Amplitude-based gating was consistently better suited to accommodate abnormal breathing patterns. For both phase-based and amplitude-based gating, end-exhalation provided significantly better results than end-inhalation. Conclusion: Amplitude-based gating reliably outperformed phase-based gating, and end-exhalation was more suitable than end-inhalation. These results will be used to guide future dose-escalation trials. Research funding provided by Varian Medical Systems to Miften and Jones.

60 APPLIED LIFE SCIENCES↗

artdaq : DAQ software development made simple

For a few years now, the artdaq data acquisition software toolkit has provided numerous experiments with ready-to-use components which allow for rapid development and deployment of DAQ systems. Developed within the Fermilab Scientific Computing Division, artdaq provides data transfer, event building, run control, and event analysis functionality. This latter feature includes built-in support for the art event analysis framework, allowing experiments to run art modules for real-time filtering, compression, disk writing and online monitoring; as art, also developed at Fermilab, is also used for online analysis, a major advantage of artdaq is that it allows developers to easily switch between developing online and online software. artdaq continues to be improved. Support for an alternate mode of running whereby data from some subdetector components are only streamed if requested has been added; this option will reduce unnecessary DAQ throughput. Real-time reporting of DAQ metrics has been implemented, along with the flexibility to choose the format through which experiments receive the reports; these formats include the Ganglia, Graphite and syslog software packages, along with at ASCII files. Additionally, work has been performed investigating more flexible modes of online monitoring, including the capability of being able to run multiple online monitoring processes on different hosts, each running its own set of art modules. Finally, a web-based GUI interface through which users can configure details of their DAQ system has been implemented, increasing the ease of use of the system. Already successfully deployed on the LArIAT, DarkSide-50, DUNE 35ton and Mu2e experiments, artdaq will be employed for SBND and is a strong candidate for use on ICARUS and protoDUNE. With each experiment comes new ideas for how artdaq can be made more flexible and powerful; the above improvements will be described, along with potential ideas for the future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-I-93: Improved Imaging Quality for Multislice Helical CT Via Sparsity Regularized Iterative Image Reconstruction Method Based On Tensor Framelet

Purpose: Inspired by compressive sensing, sparsity regularized iterative reconstruction method has been extensively studied. However, its utility pertinent to multislice helical 4D CT for radiotherapy with respect to imaging quality, dose, and time has not been thoroughly addressed. As the beginning of such an investigation, this work carries out the initial comparison of reconstructed imaging quality between sparsity regularized iterative method and analytic method through static phantom studies using a state-of-art 128-channel multi-slice Siemens helical CT scanner. Methods: In our iterative method, tensor framelet (TF) is chosen as the regularization method for its superior performance from total variation regularization in terms of reduced piecewise-constant artifacts and improved imaging quality that has been demonstrated in our prior work. On the other hand, X-ray transforms and its adjoints are computed on-the-fly through GPU implementation using our previous developed fast parallel algorithms with O(1) complexity per computing thread. For comparison, both FDK (approximate analytic method) and Katsevich algorithm (exact analytic method) are used for multislice helical CT image reconstruction. Results: The phantom experimental data with different imaging doses were acquired using a state-of-art 128-channel multi-slice Siemens helical CT scanner. The reconstructed image quality was compared between TF-based iterative method, FDK and Katsevich algorithm with the quantitative analysis for characterizing signal-to-noise ratio, image contrast, and spatial resolution of high-contrast and low-contrast objects. Conclusion: The experimental results suggest that our tensor framelet regularized iterative reconstruction algorithm improves the helical CT imaging quality from FDK and Katsevich algorithm for static experimental phantom studies that have been performed.

60 APPLIED LIFE SCIENCES↗

An optimized FM-index library for nucleotide and amino acid search

Abstract Background Pattern matching is a key step in a variety of biological sequence analysis pipelines. The FM-index is a compressed data structure for pattern matching, with search run time that is independent of the length of the database text. Implementation of the FM-index is reasonably complicated, so that increased adoption will be aided by the availability of a fast and flexible FM-index library. Results We present AvxWindowedFMindex (AWFM-index), a lightweight, open-source, thread-parallel FM-index library written in C that is optimized for indexing nucleotide and amino acid sequences. AWFM-index introduces a new approach to storing FM-index data in a strided bit-vector format that enables extremely efficient computation of the FM-index occurrence function via AVX2 bitwise instructions, and combines this with optional on-disk storage of the index’s suffix array and a cache-efficient lookup table for partial k-mer searches. The AWFM-index performs exact match count and locate queries faster than SeqAn3’s FM-index implementation across a range of comparable memory footprints. When optimized for speed, AWFM-index is $$\sim $$ ∼ 2–4x faster than SeqAn3 for nucleotide search, and $$\sim $$ ∼ 2–6x faster for amino acid search; it is also $$\sim $$ ∼ 4x faster with similar memory footprint when storing the suffix array in on-disk SSD storage. Conclusions AWFM-index is easy to incorporate into bioinformatics software, offers run-time performance parameterization, and provides clients with FM-index functionality at both a high-level (count or locate all instances of a query string) and low-level (step-wise control of the FM-index backward-search process). The open-source library is available for download at https://github.com/TravisWheelerLab/AvxWindowFmIndex.

59 BASIC BIOLOGICAL SCIENCES↗

Effects of build orientation and heat treatment on the evolution of microstructure and mechanical properties of alloy Mar-M-509 fabricated via laser powder bed fusion

We present the main results from an experimental investigation into the consequences of various microstructural features, created by laser powder bed fusion (LPBF) and subsequent heat treatments (HTs), in alloy Mar-M-509 on several aspects of plastic deformation including mechanical anisotropy and elongation-to-fracture (ETF). To ensure successful manufacturing of the alloy, porosity fraction and distribution are first characterized using micro X-ray computed tomography. Next, grain structure, crystallographic texture, and regions of recrystallization in the studied microstructures are measured using electron backscattered diffraction (EBSD). Lastly, chemistry, distribution, and morphological features of carbide phases are extracted using electron microscopy and X-ray diffraction. Strength in tension and compression are measured at room temperature for different initial microstructures created by variations in manufacturing conditions and sample orientations with respect to sample processing frame. While the strength of the alloy varies with sample orientation by approximately 30% in the as-built condition, the alloy is softer, more ductile, and approximately isotropic after HT. These results are discussed and critically compared with the data reported for the as-cast material. The alloy manufactured via LPBF is found to be significantly stronger and more ductile than the same alloy produced by casting. The interesting deformation behavior characteristics of the samples in different conditions are explained in terms of their microstructures. EBSD measurements reveal evolution from columnar grains along the build direction favoring a moderately strong <001> fiber texture in the as-built material to equiaxed grains favoring the {110}<001> Goss texture component after subsequent HTs. The major change in grain structure and texture is a result of recrystallization. While carbide phases precipitate primarily at dendrite and cellular interfaces in the as-built material, these phases are both intra-and inter-granular within the HT materials and coarsen with HT duration. These microstructural observations formed bases to rationalize the observed mechanical behavior of the alloy. With this being said, tailoring the alloy performance characteristics with HTs is reported on.

36 MATERIALS SCIENCE↗

Accelerating the Discovery of New, Single Phase High Entropy Ceramics via Active Learning

High-entropy ceramics have garnered interest due to their remarkable hardness, compressive strength, thermal stability, and fracture toughness; yet the discovery of new high-entropy ceramics (out of a tremendous number of possible elemental permutations) still largely requires costly, inefficient, trial-and-error experimental and computational approaches. The entropy forming ability (EFA) factor was recently proposed as a computational descriptor that positively correlates with the likelihood that a 5-metal high-entropy carbide (HECs) will form the desired single phase, homogeneous solid solution; however, discovery of new compositions is computationally expensive. If you consider 8 candidate metals, the HEC EFA approach uses 49 optimizations for each of the 56 unique 5-metal carbides, requiring a total of 2744 costly density functional theory calculations. Here, we describe an orders-of-magnitude more efficient active learning (AL) approach for identifying novel HECs. To begin, we compared numerous methods for generating composition-based feature vectors (e.g., magpie and mat2vec), deployed an ensemble of machine learning (ML) models to generate an average and distribution of predictions, and then utilized the distribution as an uncertainty. Here we then deployed an AL approach to extract new training data points where the ensemble of ML models predicted a high EFA value or was uncertain of the prediction. Our approach has the combined benefit of decreasing the amount of training data required to reach acceptable prediction qualities and biases the predictions toward identifying HECs with the desired high EFA values, which are tentatively correlated with the formation of single phase HECs. Using this approach, we increased the number of 5-metal carbides screened from 56 to 15,504, revealing 4 compositions with record-high EFA values that were previously unreported in the literature. Our AL framework is also generalizable and could be modified to rationally predict optimized candidate materials/combinations with a wide range of desired properties (e.g., mechanical stability, thermal conductivity).

36 MATERIALS SCIENCE↗

SU-E-J-172: A Quantitative Assessment of Lung Tumor Motion Using 4DCT Imaging Under Conditions of Controlled Breathing in the Management of Non-Small Cell Lung Cancer (NSCLC) Using Stereotactic Body Radiation Therapy (SBRT)

Purpose: To study breathing related tumor motion amplitudes by lung lobe location under controlled breathing conditions used in Stereotactic Body Radiation Therapy (SBRT) for NSCLC. Methods: Sixty-five NSCLC SBRT patients since 2009 were investigated. Patients were categorized based on tumor anatomic location (RUL-17, RML-7, RLL-18, LUL-14, LLL-9). A 16-slice CT scanner [GE RT16 Pro] along with Varian Realtime Position Management (RPM) software was used to acquire the 4DCT data set using 1.25 mm slice width. Images were binned in 10 phases, T00 being at maximum inspiration ' T50 at maximum expiration phase. Tumor volume was segmented in T50 using the CT-lung window and its displacement were measured from phase to phase in all three axes; superiorinferior, anterior-posterior ' medial-lateral at the centroid level of the tumor. Results: The median tumor movement in each lobe was as follows: RUL= 3.8±2.0 mm (mean ITV: 9.5 cm{sup 3}), RML= 4.7±2.8 mm (mean ITV: 9.2 cm{sup 3}), RLL=6.6±2.6 mm (mean ITV: 12.3 cm{sup 3}), LUL=3.8±2.4 mm (mean ITV: 18.5 cm{sup 3}), ' LLL=4.7±2.5 mm (mean ITV: 11.9 cm{sup 3}). The median respiratory cycle for all patients was found to be 3.81 ± 1.08 seconds [minimum 2.50 seconds, maximum 7.07 seconds]. The tumor mobility incorporating breathing cycle was RUL = 0.95±0.49 mm/s, RML = 1.35±0.62 mm/s, RLL = 1.83±0.71 mm/s, LUL = 0.98 ±0.50 mm/s, and LLL = 1.15 ±0.53 mm/s. Conclusion: Our results show that tumor displacement is location dependent. The range of motion and mobility increases as the location of the tumor nears the diaphragm. Under abdominal compression, the magnitude of tumor motion is reduced by as much as a factor of 2 in comparison to reported tumor magnitudes under conventional free breathing conditions. This study demonstrates the utility of abdominal compression in reducing the tumor motion leading to reduced ITV and planning tumor volumes (PTV)

60 APPLIED LIFE SCIENCES↗

Shock-Induced Solid-State Reactions in Powders: An Experimentally-Based Reassessment

We have performed a series of ten planar impact experiments on six different materials, including certain reactive powders and two inert materials, using Sandia's 89 - mm powder gun at the STAR facility. Time - resolved particle - velocity histories were determined during each of the experiments from one or more VISAR measurements. We have analyzed the results of these measurements 1) by using jump conditions to determine shock and first reshock states and 2) by comparing measured particle velocity histories to synthetic histories predicted by one - dimensional computational analyses using the CTH shock physics code with various models for inert and reactive materials . These comparisons are consistent with the conclusion for these particular reactive powders, that for the duration of shock loading either 1) there is insignificant reaction or 2) the products of any reaction are indistinguishable from the reactants under the experimental conditions. Shock and reshock states were extracted for shock pressures between 5 and 40 GPa. Densities were at or greater than the theoretical maximum zero - pressure density of the starting mixture. This result would be expected if there were no reaction or negligible reaction for the first two shock states. Two experiments were performed on one reactive powder in a "ring - down " geometry to look for evidence of vapor production on pressure release. In both cases, the measured velocity continued to increase slowly over a period of microseconds for the du ration of the experiment. This observation suggests that vapor is produced along the release path, but information about the mechanism for vapor production cannot be extracted from these data. While it is possible that vapor is produced by a shock - induced reaction involving more than one of the original constituents, a simpler interpretation is that the vapor is made up of products of shock - induced decomposition reactions and/or simple vaporization of the constituents as would be expected to take place under the conditions of these experiments. Other sources of vapor could be water adsorbed on grain surfaces and air originally in the voids. Thus it is not necessary to invoke significant recombination reactions to explain the data. However, in the absence of ring - down control experiments, the possibility remains open. These conclusions are different from those of previous workers, but reassessment of a subset of the earlier data yields results consistent with the present work, i.e., the shock compression data do not provide evidence for strong exothermic reactions.

36 MATERIALS SCIENCE↗

Universal method for the optimization of HDC coating uniformity on non-planar, non-stationary substrates for inertial confinement fusion targets

The thickness uniformity of chemical vapor deposited (CVD) diamond coatings on non-planar, non-stationary substrates depends on both the intrinsic instantaneous coating thickness distribution (ICTD) of the coating conditions used and, if applicable, on the frequency of substrate reorientation. While important for many CVD diamond applications, the relative impact of the ICTD and substrate reorientation on the coating thickness uniformity has not been studied. In this work, we systematically investigate the effect of these factors for microwave-plasma chemical vapor deposition (MPCVD) of diamond (referred to as high density carbon (HDC) in the inertial confinement fusion (ICF) community) coatings on spherical, rolling substrates. This coating technique is used to fabricate capsules for ICF experiments, which require extreme coating uniformity with <0.3 % thickness variation (so-called Mode 1 or M1) to ensure symmetric compression of imploding targets. To extract the otherwise unobservable reorientation timescale (Δt), Monte Carlo simulations were performed using experimental ICTD data as input. This combined approach confirms scaling relationships between the substrate reorientation timescale as well as coating thickness and coating uniformity, as expected from a 3D random walk. Simulations confirm that M1 is Rayleigh-distributed and scales as (Δt) 1/2 , consistent with the randomization of two angles that determine orientation of a sphere. We also demonstrate that, under the conditions studied, Δt is the dominant factor in determining thickness uniformity while the intrinsic ICTD has minimal impact. Finally, experiments show that Δt can be affected by total batch size under constant agitation conditions due to space constraints that limit the capsule reorientation kinetics. In conclusion, this study highlights the utility of a combined experiment-simulation approach as a general methodology for understanding and improving coating uniformity on non-planar, non-stationary substrates.

Capsule↗

SU-E-T-776: Use of Quality Metrics for a New Hypo-Fractionated Pre-Surgical Mesothelioma Protocol

Purpose: The “SMART” (Surgery for Mesothelioma After Radiation Therapy) approach involves hypo-fractionated radiotherapy of the lung pleura to 25Gy over 5 days followed by surgical resection within 7. Early clinical results suggest that this approach is very promising, but also logistically challenging due to the multidisciplinary involvement. Due to the compressed schedule, high dose, and shortened planning time, the delivery of the planned doses were monitored for safety with quality metric software. Methods: Hypo-fractionated IMRT treatment plans were developed for all patients and exported to Quality Reports™ software. Plan quality metrics or PQMs™ were created to calculate an objective scoring function for each plan. This allows for an objective assessment of the quality of the plan and a benchmark for plan improvement for subsequent patients. The priorities of various components were incorporated based on similar hypo-fractionated protocols such as lung SBRT treatments. Results: Five patients have been treated at our institution using this approach. The plans were developed, QA performed, and ready within 5 days of simulation. Plan Quality metrics utilized in scoring included doses to OAR and target coverage. All patients tolerated treatment well and proceeded to surgery as scheduled. Reported toxicity included grade 1 nausea (n=1), grade 1 esophagitis (n=1), grade 2 fatigue (n=3). One patient had recurrent fluid accumulation following surgery. No patients experienced any pulmonary toxicity prior to surgery. Conclusion: An accelerated course of pre-operative high dose radiation for mesothelioma is an innovative and promising new protocol. Without historical data, one must proceed cautiously and monitor the data carefully. The development of quality metrics and scoring functions for these treatments allows us to benchmark our plans and monitor improvement. If subsequent toxicities occur, these will be easy to investigate and incorporate into the metrics. This will improve the safe delivery of large doses for these patients.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP1-15: Sliding Window Prior Data Assisted Compressed Sensing for MRI Lung Tumor Tracking

Purpose: Prior Data Assisted Compressed Sensing (PDACS) is a partial k-space acquisition and reconstruction method for mobile tumour (i.e. lung) tracking using on-line MRI in radiotherapy. PDACS partially relies on prior data acquired at the beginning of dynamic scans, and is therefore susceptible to artifacts in longer duration scan due to slow drifts in MR signal. A novel sliding window strategy is presented to mitigate this effect. Methods: MRI acceleration is simulated by retrospective removal of data from the fully sampled sets. Six lung cancer patients were scanned (clinical 3T MRI) using a balanced steady state free precession (bSSFP) sequence for 3 minutes at approximately 4 frames per second, for a total of 650 dynamics. PDACS acceleration is achieved by undersampling of k-space in a single pseudo-random pattern. Reconstruction iteratively minimizes the total variations while constraining the images to satisfy both the currently acquired data and the prior data in missing k-space. Our novel sliding window technique (SW-PDACS), uses a series of distinct pseudo-random under-sampling patterns of partial k-space – with the prior data drawn from a sliding window of the most recent data available. Under-sampled data, simulating 2 – 5x acceleration are reconstructed using PDACS and SW-PDACS. Three quantitative metrics: artifact power, centroid error and Dice’s coefficient are computed for comparison. Results: Quantitively metric values from all 6 patients are averaged in 3 bins, each containing approximately one minute of dynamic data. For the first minute bin, PDACS and SW-PDACS give comparable results. Progressive decline in image quality metrics in bins 2 and 3 are observed for PDACS. No decline in image quality is observed for SW-PDACS. Conclusion: The novel approach presented (SW-PDACS) is a more robust for accelerating longer duration (>1 minute) dynamic MRI scans for tracking lung tumour motion using on-line MRI in radiotherapy. B.G. Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization).

60 APPLIED LIFE SCIENCES↗

Compressed-sensing-based content-driven hierarchical reconstruction: Theory and application to C-arm cone-beam tomography

Purpose: This paper addresses the reconstruction of x-ray cone-beam computed tomography (CBCT) for interventional C-arm systems. Subsampling of CBCT is a significant issue with C-arms due to their slow rotation and to the low frame rate of their flat panel x-ray detectors. The aim of this work is to propose a novel method able to handle the subsampling artifacts generally observed with analytical reconstruction, through a content-driven hierarchical reconstruction based on compressed sensing. Methods: The central idea is to proceed with a hierarchical method where the most salient features (high intensities or gradients) are reconstructed first to reduce the artifacts these features induce. These artifacts are addressed first because their presence contaminates less salient features. Several hierarchical schemes aiming at streak artifacts reduction are introduced for C-arm CBCT: the empirical orthogonal matching pursuit approach with the ℓ{sub 0} pseudonorm for reconstructing sparse vessels; a convex variant using homotopy with the ℓ{sub 1}-norm constraint of compressed sensing, for reconstructing sparse vessels over a nonsparse background; homotopy with total variation (TV); and a novel empirical extension to nonlinear diffusion (NLD). Such principles are implemented with penalized iterative filtered backprojection algorithms. For soft-tissue imaging, the authors compare the use of TV and NLD filters as sparsity constraints, both optimized with the alternating direction method of multipliers, using a threshold for TV and a nonlinear weighting for NLD. Results: The authors show on simulated data that their approach provides fast convergence to good approximations of the solution of the TV-constrained minimization problem introduced by the compressed sensing theory. Using C-arm CBCT clinical data, the authors show that both TV and NLD can deliver improved image quality by reducing streaks. Conclusions: A flexible compressed-sensing-based algorithmic approach is proposed that is able to accommodate for a wide range of constraints. It is successfully applied to C-arm CBCT images that may not be so well approximated by piecewise constant functions.

60 APPLIED LIFE SCIENCES↗

Automated registration of diagnostic to prediagnostic x-ray mammograms: Evaluation and comparison to radiologists' accuracy

Purpose: To compare and evaluate intensity-based registration methods for computation of serial x-ray mammogram correspondence. Methods: X-ray mammograms were simulated from MRIs of 20 women using finite element methods for modeling breast compressions and employing a MRI/x-ray appearance change model. The parameter configurations of three registration methods, affine, fluid, and free-form deformation (FFD), were optimized for registering x-ray mammograms on these simulated images. Five mammography film readers independently identified landmarks (tumor, nipple, and usually two other normal features) on pairs of diagnostic and corresponding prediagnostic digitized images from 52 breast cancer cases. Landmarks were independently reidentified by each reader. Target registration errors were calculated to compare the three registration methods using the reader landmarks as a gold standard. Data were analyzed using multilevel methods. Results: Between-reader variability varied with landmark (p<0.01) and screen (p=0.03), with between-reader mean distance (mm) in point location on the diagnostic/prediagnostic images of 2.50 (95% CI 1.95, 3.15)/2.84 (2.24, 3.55) for nipples and 4.26 (3.43, 5.24)/4.76 (3.85, 5.84) for tumors. Registration accuracy was sensitive to the type of landmark and the amount of breast density. For dense breasts ({>=}40%), the affine and fluid methods outperformed FFD. For breasts with lower density, the affine registration surpassed both fluid and FFD. Mean accuracy (mm) of the affine registration varied between 3.16 (95% CI 2.56, 3.90) for nipple points in breasts with density 20%-39% and 5.73 (4.80, 6.84) for tumor points in breasts with density <20%. Conclusions: Affine registration accuracy was comparable to that between independent film readers. More advanced two-dimensional nonrigid registration algorithms were incapable of increasing the accuracy of image alignment when compared to affine registration.

60 APPLIED LIFE SCIENCES↗