Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detection Limit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

RESULTS OF CESIUM MASS TRANSFER TESTING FOR NEXT GENERATION SOLVENT WITH HANFORD WASTE SIMULANT AP-101

SRNL has performed an Extraction, Scrub, Strip (ESS) test using the next generation solvent and AP-101 Hanford Waste simulant. The results indicate that the next generation solvent (MG solvent) has adequate extraction behavior even in the face of a massive excess of potassium. The stripping results indicate poorer behavior, but this may be due to inadequate method detection limits. SRNL recommends further testing using hot tank waste or spiked simulant to provide for better detection limits. Furthermore, strong consideration should be given to performing an actual waste, or spiked waste demonstration using the 2cm contactor bank. The Savannah River Site currently utilizes a solvent extraction technology to selectively remove cesium from tank waste at the Multi-Component Solvent Extraction unit (MCU). This solvent consists of four components: the extractant - BoBCalixC6, a modifier - Cs-7B, a suppressor - trioctylamine, and a diluent, Isopar L{trademark}. This solvent has been used to successfully decontaminate over 2 million gallons of tank waste. However, recent work at Oak Ridge National Laboratory (ORNL), Argonne National Laboratory (ANL), and Savannah River National Laboratory (SRNL) has provided a basis to implement an improved solvent blend. This new solvent blend - referred to as Next Generation Solvent (NGS) - is similar to the current solvent, and also contains four components: the extractant - MAXCalix, a modifier - Cs-7B, a suppressor - LIX-79{trademark} guanidine, and a diluent, Isopar L{trademark}. Testing to date has shown that this 'Next Generation' solvent promises to provide far superior cesium removal efficiencies, and furthermore, is theorized to perform adequately even in waste with high potassium concentrations such that it could be used for processing Hanford wastes. SRNL has performed a cesium mass transfer test in to confirm this behavior, using a simulant designed to simulate Hanford AP-101 waste.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Report for Batch Leach Analyses on Sediments at 100-HR-3 Operable Unit, Boreholes C7620, C7621, C7622, C7623, C7626, C7627, C7628, C7629, C7630, and C7866

This is a revision to a previously released report. This revision contains additional analytical results for the sample with HEIS number B2H4X7. Between November 4, 2010 and October 26, 2011 sediment samples were received from 100-HR-3 Operable Unit for geochemical studies. The analyses for this project were performed at the 331 building located in the 300 Area of the Hanford Site. The analyses were performed according to Pacific Northwest National Laboratory (PNNL) approved procedures and/or nationally recognized test procedures. The data sets include the sample identification numbers, analytical results, estimated quantification limits (EQL), and quality control data. The preparatory and analytical quality control requirements, calibration requirements, acceptance criteria, and failure actions are defined in the on-line QA plan 'Conducting Analytical Work in Support of Regulatory Programs' (CAW). This QA plan implements the Hanford Analytical Services Quality Assurance Requirements Documents (HASQARD) for PNNL. Samples were received with a chain of custody (COC) and were analyzed according to the sample identification numbers supplied by the client. All Samples were refrigerated upon receipt until prepared for analysis. All samples were received with custody seals intact unless noted in the Case Narrative. Holding time is defined as the time from sample preparation to the time of analyses. The prescribed holding times were met for all analytes unless noted in the Case Narrative. All reported analytical results meet the requirements of the CAW or client specified SOW unless noted in the case narrative. Due to the requirements of the statement of work and sampling events in the field, the 28 day and the 48 hr requirements cannot be met. The statement of work requires samples to be selected at the completion of the borehole. It is not always possible to complete a borehole and have the samples shipped to the laboratory within the hold time requirements. Duplicate RPD for Uranium 238 (38.9%) was above the acceptance limit (35) in 1E05003-DUP1 for ICPMS-Tc-U-WE The sample result is less than 10 times the detection limits. Duplicate recoveries are not applicable to this analyte. Duplicate RPD for Silver 107 (68.2%) was above the acceptance limit (35) in 2C06004-DUP1 for ICPMS-RCRA-AE The sample result is less than 10 times the detection limits. Duplicate recoveries are not applicable to this analyte. Matrix Spike Recovery for Chromium, Hexavalent (48.8%) was outside acceptance limits (75-125) in 1E23001-MS1 for Hexavalent Chromium/Soil. Potential Matrix interference. Sample results associated with this batch are below the EQL. There should be no impact to the data as reported. Matrix Spike Recovery for Chromium, Hexavalent (50.2%) was outside acceptance limits (75-125) in 2B22010-MS1 for Hexavalent Chromium/Soil. Potential Matrix interference. Sample results associated with this batch are below the EQL. There should be no impact to the data as reported.

54 ENVIRONMENTAL SCIENCES↗

Laser-Induced Carbon-Based Smart Flexible Sensor Array for Multiflavors Detection

We report a flexible sensor array electronic tongue system that is fabricated on a polymer substrate by the laser direct writing process for multiflavor detection. Electronic tongue is a sensing system that is applied to detect different elements with the same sensor array. By analyzing responses from different measurement units, it enables a cross-sensitivity, namely, the ability of the system to responding to a range of different analytes in solution without specific functionalization of sensors. In this article, a six-unit sensing array system was fabricated by a laser direct writing process. Sensing units were introduced on a flexible polyamide surface. A high surface–volume ratio porous carbon structure was created by a laser-induced carbonization process, which provides stable conductive carbon electrodes with high sensitivity. Different surface treatments, such as gold plating, reduced-graphene oxide coating, and polyaniline coating, were accomplished for different measurement units. By applying principal component analysis, this sensing system shows a promising result for the detection of multiple flavors. The detection limit for each element is about 0.1 mM for NaCl and sugar solutions. Also, it is able to detect 10 –4 times diluted commercial table vinegar solution, which originally contains 5% acetic acid. The detection limit is theoretically lower than the human threshold of 10 mM for NaCl and sugar. Besides, the sensing system shows a high sensitivity and selectivity for mixed elements. Here, by mapping the data points, the sensor system could detect flavor combinations and provide a reliable prediction of analyte concentration ratios.

47 OTHER INSTRUMENTATION↗

Launch Complex 39B, SWMU 009, 2023 Performance Monitoring and Air Sparge Expansion Construction Completion Report, Kennedy Space Center, Florida

The 2023 Performance Monitoring and Construction Completion Report (PM-CCR) presents the findings, observations, and results for Air Sparging (AS) operations and expansion activities, as well as sitewide groundwater monitoring for Launch Complex 39B (LC39B), Solid Waste Management Unit (SWMU) 009, at Kennedy Space Center (KSC), Florida. The reporting period for activities covered under this PM-CCR is from January 1, 2023, to December 31, 2023. At LC39B, AS operations began in 2017 in the area west of the launch pad, in the liquid oxygen (LOX) tank area located northwest of the launch pad, and in an area outside of the perimeter fence to protect nearby Outstanding Florida Waters (OFW). The LC39B AS system was installed with 279 AS wells to depths ranging from 23 to 60 feet below land surface (bls), including the sump, correlating to top of screen depths ranging from 20 to 57 feet bls. In December 2022, a total of 22 AS wells were abandoned to support launch pad crane operations, and in November 2023, the system was expanded with five additional AS wells installed to 13 or 17 feet bls near the LOX tank. The remedial objective of the LC39B AS Interim Measure (IM) is to actively decrease concentrations of contaminants of concern (COCs) in groundwater, specifically trichloroethene (TCE), cis-1,2-Dichloroethene (cDCE), and vinyl chloride (VC), to less than their respective Natural Attenuation Default Concentrations (NADCs), so LC39B can transition into a Long-Term Monitoring (LTM) program. This PM-CCR presents the following information for LC39B: • AS system operations and maintenance (O&M) (Year 7 of operation) from January 2023 to December 2023, to include AS trailer relocation in March 2023 and subsequent replacement and re-start in June 2023. • Construction completion details for AS system expansion, which included installation of five new AS wells and one new monitoring well in November 2023. As part of expansion activities, soil samples were also collected for petroleum analysis; no exceedances were identified, and no further investigation for petroleum is warranted. • Performance monitoring results for groundwater sampling events conducted in May/June 2023 (30 wells) and November 2023 (31 wells) in the AS IM area and in the Low Concentration Plume (LCP) areas located north and east of the launch pad for volatile organic compound (VOC) analysis. • Sampling results for one monitoring well, LOX-IW0012S, which is sampled for aluminum on an annual basis (May/June 2023). This well was resampled in November 2023 for both total and dissolved aluminum. Due to a communication error with the laboratory, the May/June 2023 sample was analyzed for total aluminum only. • Groundwater sampling results for per- and polyfluoroalkyl substances (PFAS) collected from seven monitoring wells during the May/June 2023 event to further investigate the Former Sewage Treatment Plant #6 and Percolation Pond area, west of the launch pad. O&M and performance monitoring results show that the AS system at LC39B is operating as designed and meeting performance criteria. Overall runtime was 45 percent (%) during the reporting period (January to December), but the operational runtime was 78% during the timeframe when the system could run (June to December). The most significant downtime contributor was post-launch crane operations following the Artemis launch on November 16, 2022, which lasted until June 2023. During that timeframe, the AS trailer at LC39B was relocated to another KSC remediation site (Wilson Corners) and was subsequently replaced with the AS trailer from the Paint & Oil Locker (POL) remediation site at KSC to resume AS system operations. Performance monitoring results in the AS IM and LCP areas continue to show reduction in COC concentrations over time when compared to baseline levels. In 2023, only one monitoring well (MW0048) detected a COC exceeding its NADC (VC at 740 micrograms per liter [µg/L]), which marks the baseline result for this new well installed during system expansion. Across the rest of the site, VC concentrations have declined or remained stable during the 2023 sampling events. Excluding MW0048, the highest VC result in 2023 was during the May/June sampling event with a concentration of 63 µg/L at MW0032, which is located near MW0048 and the AS expansion area by the LOX tank. TCE was detected in select monitoring wells in the IM area in 2023, but only two locations exceeded the State of Florida Groundwater Cleanup Target Level (GCTL): MW0032 (21 µg/L in May/June 2023 and 9.1 µg/L in November 2023) and MW0036 (5.0 µg/L in November 2023). MW0036 is also located near the LOX tank, on the north side, where the AS system is still operational (Zone Z4). cDCE and trans-1,2-dichloroethene concentrations were less than laboratory method detection limits or their respective GCTLs in all wells sampled in 2023. Near the OFW located northwest of the launch complex, all COC concentrations were less than laboratory method detection limits from monitoring wells (MW0039, MW0040, and LOXTA0002S) sampled in 2023. Aluminum results from LOX-IW0012S, which has been sampled routinely since 2006, detected a total aluminum concentration of 3,900 µg/L during the May/June 2023 sampling event. Results from the November 2023 event detected 5,700 µg/L for total aluminum and 5,500 µg/L for dissolved aluminum. These concentrations slightly decreased from the previous year but remain relatively consistent with historical detections. Aluminum will continue to be sampled on an annual basis at this well as results still exceed the GCTL of 200 µg/L and the Upper Limit of the KSC Background Concentration of 280 µg/L. PFAS results detected nine different PFAS compounds (out of 32 analyzed) from seven wells sampled. Two PFAS compounds, perfluorooctanesulfonic acid (PFOS) and perfluorooctanoic acid (PFOA), currently have FDEP Provisional GCTLs of 70 nanograms per liter (ng/L). All seven samples collected resulted in concentrations less than the FDEP Provisional GCTLs for both PFAS compounds; no exceedances were observed. PFOS and PFOA also have assigned United States Environmental Protection Agency (USEPA) Maximum Contaminant Levels (MCLs) of 4 nanograms per liter (ng/L). None of the PFOS results exceeded the USEPA MCLs. PFOA was detected in two samples above the USEPA MCL at concentrations of 5.8 ng/L (ECS-IW0009I) and 5.5 ng/L (ECS-IW0009S). Three other PFAS compounds, perfluorohexanesulfonic acid (PFHxS), perfluoro-n-nonanoic acid (PFNA), and hexafluoropropylene oxide dimer acid (GenX), currently have USEPA MCLs of 10 ng/L. PFHxS, PFNA, and GenX were not detected at concentrations greater than their respective USEPA MCLs in any of the seven wells. PFAS compounds without FDEP Provisional GCTLs or USEPA MCLs were screened against USEPA RSLs. No other detections exceeded their respective USEPA RSLs. Additional PFAS sampling will be conducted as part of a future PFAS Site Assessment. Based on O&M activities and performance monitoring, the following is recommended for LC39B: • Continue with Year 8 AS system operation within Zone Z4, which includes the AS expansion area. Zone Z3, which has been off since 2018, should remain off as no rebound has been observed. Zones Z1 and Z2, which were turned off at the end of 2022, will remain shut down as monitoring well results have consistently been below GCTLs or have low-level detections with stable or decreasing trends (Meeting Minute 2402-M10, Decision 2402-D30). • Continue with performance monitoring in 2024 with the same monitoring well network as 2023, except with the addition of MW0048 in both semi-annual events. Baseline concentrations for this well were collected during the November 2023 performance monitoring event. Semi-annual sampling should be planned for the May 2024 and November 2024 timeframes (Meeting Minute 2402-M10, Decision 2402-D31). • Continue sampling monitoring well, LOX-IW0012S, for aluminum (total and dissolved) on an annual basis in May 2024. It is also recommended to re-develop this well prior to the next sampling event (Meeting Minute 2402-M10, Decision 2402-D32). The above recommendations for LC39B were presented at the February 2024 KSCRT Meeting, with Team consensus reached on the path forward. The contents of this PM-CCR were also presented at this meeting.

Deborah M Wilson↗

Toxicological Assessment of ISS Air Quality: April - May 2013

A summary of the analytical results from 4 mini-grab sample (mGSCs) collected on ISS and returned aboard 33S is shown in Table 1. Due to the launch delay of the ATV4 resupply mission, monthly samples were reduced in April and May by omitting sampling of the Service Module in order to ensure contingency samplers were available if needed. Complete data tables of all measured concentrations and corresponding T-values based on 180-day SMACs are enclosed. detection limit for all target compounds, except m/p-xylenes and hexachloro-1, 3-butadiene was 0.025 mg/cu m. The detection limit for m/p-xylenes and hexachloro-1, 3-butadiene and all non-target compounds was 0.05 mg/cu m. The average recoveries of the 3 surrogate standards from the mGSCs were as follows: C-13-acetone, 116 +/- 12%; D-5-fluorobenzene, 117 +/- 7%; and D-5-chlorobenzene, 111 +/- 15%. Initial measured sample pressures were between 13.9 and 14.1 psia for all samples, indicating nominal sample collection. A summary of the analytical results from 3 pairs of passive-diffusion formaldehyde badges collected on ISS and returned aboard 33S is also provided in Table 1. In an effort to conserve samples due to the delay of the ATV4 resupply mission, FMK sampling was only conducted in the US Lab in May. Positive control recoveries (1 trip and 2 lab controls) were 79%, 87%, and 116% respectively.

Meyers, Valerie↗

UV/Near-IR Aerosol Absorption Monitor

In this DOE SBIR Phase I study, we have designed and constructed two prototypes demonstrating proof of concept for a new aerosol measurement instrument: a UV/near-IR aerosol absorption monitor. One prototype operates at 360nm and the other at 1064nm. From the laboratory testing and evaluation, we obtained the following technical specifications for the two prototypes: (A) Photoacoustic measurements of aerosol light absorption at 360nm and 1064 nm; (B) Detection limit of 1.0 Mm-1 in 10s-averaging and 0.36 Mm-1 in 100s at 1064nm; (C) Detection limit of 9 Mm-1 in 10s at 360nm; (D) Time response of 4.3 ± 0.6 s, using the 90% criteria; (E) Linear dynamic range from 0.36 Mm to 250 Mm-1 at 1064nm; (F) Sample flow rate of 0.5-2.0 liter per minute; (G) Continuous measurement at 1s sampling rate; (H) An aerosol-based calibration approach; (I) Dimension of 56cm×43cm×25cm and 25kg for the near-IR prototype; while 66cm×43cm×38cm and 30kg for the UV prototype. In this Phase I study, we changed the modulation approach applied to the UV prototype to improve its detection sensitivity. Using an optical chopper to chop the laser beam instead of the electronic modulation on its power supply, we were able to increase the effective laser power and thereby improve the sensitivity by a factor of 2.1. However there is a tradeoff of utilizing a chopper. This approach can only produce a single modulation frequency, presenting an obstacle to combining the UV and near-IR aerosol absorption monitors into a single two-wavelength measurement instrument. Given that the near-IR prototype meets all the desired technical specifications from the DoE SBIR program, this instrument will be ready to be commercialized in the Phase II program. On the other hand, in addition to a different modulation scheme from the near-IR model, the UV aerosol absorption monitor needs some improvements to achieve the desired technical objective in measurement sensitivity. Thus the future Phase II program would primarily focus on improving the UV model and developing both the UV and near-IR aerosol absorption monitors into standalone commercial products.

54 ENVIRONMENTAL SCIENCES↗

Collection and analysis of NASA clean room air samples

The environment of the HALOE assembly clean room at NASA Langley Research Center is analyzed to determine the background levels of airborne organic compounds. Sampling is accomplished by pumping the clean room air through absorbing cartridges. For volatile organics, cartridges are thermally desorbed and then analyzed by gas chromatography and mass spectrometry, compounds are identified by searching the EPA/NIH data base using an interactive operator INCOS computer search algorithm. For semivolatile organics, cartridges are solvent entracted and concentrated extracts are analyzed by gas chromatography-electron capture detection, compound identification is made by matching gas chromatogram retention times with known standards. The detection limits for the semivolatile organics are; 0.89 ng cu m for dioctylphlhalate (DOP) and 1.6 ng cu m for polychlorinated biphenyls (PCB). The detection limit for volatile organics ranges from 1 to 50 parts per trillion. Only trace quantities of organics are detected, the DOP levels do not exceed 2.5 ng cu m and the PCB levels do not exceed 454 ng cu m.

Sheldon, L. S.↗

An improved Method for Determining Transient Fuel Dilution of Oil in an Internal-Combustion Engine Using Laser-Induced Florescence and Multivariate Least Square Calibration

An optical diagnostic, based on laser-induced fluorescence (LIF), has been developed for on-engine measurements of real-time fuel dilution of engine oil or fuel in oil (FIO). Fuel dilution of oil is broadly relevant to advancing engine technology including durability, calibration, and catalyst-system management, and believed to promote destructive stochastic pre-ignition (SPI) during high-load engine operations. While standard (e.g., ASTM D3524-90) methods are not capable of real-time transient measurements, the LIF technique resolves transient dilution on the minutes time scale. We have expanded on our original FIO instrument development by introducing an improved analysis based on multivariate least square chemometrics analysis. The measurement uses a fuel dye (180–1300 parts per million, by mass) and monitors for its presence in the oil using 532 nm excitation and LIF. While the original FIO instrument utilized a two-color ratio method for analysis, the improved chemometric analysis uses the fully resolved LIF dye spectra to provide better predictive FIO accuracy (>92%) over a wide FIO range (1.5–14%) typical of engine application. We also investigate the effect of oil temperature on the LIF signal. Limited engine applications for demonstrating and validating the improved FIO instrument are shown, and the related data used to quantify practical detection limit and sensitivity. The improved analysis is insensitive to laser power fluctuation and change in detector integration time, providing an excellent FIO sensitivity (1–2%) and detection limit (0.01 %FIO) over a wide range of loads and injection timings, illustrating this updated approach to be a promising tool for advancing engine technology.

42 ENGINEERING↗

Neutron Screening Measurements of 110 gallon drums at T Plant

The Pacific Northwest National Laboratory (PNNL) Nondestructive Assay (NDA) Service Center was contracted to develop and demonstrate a simple and inexpensive method of assaying 110 gallon drums at the Hanford Site’s T-Plant. The drums contained pucks of crushed old drums used for storage of transuranic (TRU) waste. The drums were to be assayed to determine if they meet the criteria for TRU or Low Level Waste (LLW). Because of the dense matrix (crushed steel drums) gamma measurement techniques were excluded and a mobile, configurable neutron system, consisting of four sequentially connected slab detectors was chosen to be used for this application. An optimum measurement configuration was determined through multiple test measurements with californium source. Based on these measurements the initial calibration of the system was performed applying the isotopic composition for aged weapon-grade plutonium. A series of background and blank puck drum measurements allowed estimating detection limits for both total (singles) and coincidence (doubles) counting techniques. It was found that even conservative estimates for minimum detection concentration using singles count rate were lower than the essential threshold of 100 nCi/g. Whereas the detection limit of coincidence counting appeared to be about as twice as high of the threshold. A series of measurements intended to verify the technique and revise the initial calibration obtained were performed at the Waste Receiving and Processing (WRAP) facility with plutonium standards. Standards with a total mass of 0.3 g of plutonium (which is estimated to be equivalent of 100 nCi/g for net waste weight of 300 kg) loaded in the test puck drum were clearly detected. The following measurements of higher plutonium loadings verified the calibration factors obtained in the initial exercise. The revised and established calibration factors were also confirmed within established uncertainties by additional measurements of plutonium standards in various locations in the test drum. Due to necessity to dispense the blank test drum an alternative method of baseline determination was established during field measurements. Count rates of ambient background were corrected by the differences between observed background and blank test drum count rates which were previously determined over a series of measurements. Only 31 drums out of 352 counted during the intensive measurement campaign at T-Plant were determined to be Suspect TRU. 25 of these drums were re-measured at the WRAP facility using the SuperHENC. Of the 25 drums measured, 21 were confirmed to be TRU and the remaining four LLW.

neutron measurements, TRU waste, T-Plant, configur↗

Characterization of X80 and X100 Microalloyed Pipeline Steel Using Quantitative X-ray Diffraction

Quantitative X-ray diffraction characterization of four (4) X80 and three (3) X100 microalloyed steels was undertaken. The effect of through-thickness position, processing parameters, and composition on the measured crystallite size, microstrain, and J index (relative magnitude of crystallographic texture) was determined. Microstructure analysis using optical microscopy, scanning electron microscopy, transmission electron microscopy, and electron-backscattered diffraction was also undertaken. The measured value of microstrain increased with increasing alloy content and decreasing cooling interrupt temperature. Microstructural features corresponding to crystallite size in the X80 steels were both above and below the detection limit for quantitative X-ray diffraction. The X100 steels consistently exhibited microstructure features below the crystallite size detection limit. The yield stress of each steel increased with increasing microstrain. The increase in microstrain from X80 to X100 is also associated with a change in microstructure from predominantly polygonal ferrite to bainitic ferrite.

36 MATERIALS SCIENCE↗

Improvements to the Hunter Dose tracking system

Since 1965, the Savannah River Site (SRS) has conducted deer hunts which are open to the general public. SRS performs field monitoring for cesium-137 (Cs-137) of each harvested animal to determine whether the animal may be released to the hunter. A new field system for measuring Cs-137 in the harvested animals has been developed. The system incorporates numerous enhancements compared to the original system. The original system was composed of two Ludlum Measurements scalar-driven 2 inch x 2 inch sodium iodide counters, while the new system is based on a single Ametek Ortec Digibase-driven 2 inch x 4 inch x 16 inch sodium iodide gamma spectrometer. The new system includes a series of easy-to-assemble stainless steel encapsulated lead shields. The combination of the larger detector size and lead shielding improved the detection limit of the new system by a factor of approximately three compared to the original system. This lower detection limit allows for a larger number of measurements to be directly compared to the laboratory results, in cases where animal portions have been sampled. The results from developing and using this system are presented as well as recommendations on improvements to the overall field monitoring of the SRS hunts.

61 RADIATION PROTECTION AND DOSIMETRY↗

Slow light enhanced bio sensing properties of silicon sensors

In this paper, we investigated slow light to increase sensitivity and quality factor of our recently designed bio-sensors. A finite difference time domain and Plane Wave Expansion methods are employed to figure out sensors’ performances. We proposed slow light based photonic crystal structures with elliptical cells and we obtained higher sensitivity and quality factor as previously reported. For the first proposed sensor, the results showed that quality factor increased from 570 to 723 and a detection limit below 10{sup −3}. For the second sensor, the sensitivity increased from 550 to 650 nm/RIU and the detection limit is around 10{sup −3}. These two proposed structures would offer great potential for novel compact biosensors in medical application.

36 MATERIALS SCIENCE↗

Monitoring Trace Contaminants in Air Via Ion Trap Mass Spectrometry

Recent passage of the Clean Air Act with its stricter regulation of toxic gas emissions, and the ever-growing number of applications which require faster turnaround times between sampling and analysis are two major factors which are helping to drive the development of new instrument technologies for in-situ, on-line, real-time monitoring. The ion trap, with its small size, excellent sensitivity, and tandem mass spectrometry capability is a rapidly evolving technology which is well-suited for these applications. In this paper, we describe the use of a commercial ion trap instrument for monitoring trace levels of chlorofluorocarbons (CFCs) and volatile organic compounds (VOCs) in air. A number of sample introduction devices including a direct transfer line interface, short column GC, and a cryotrapping interface are employed to achieve increasing levels of sensitivity. MS, MS/MS, and MS/MS/MS methods are compared to illustrate trade-offs between sensitivity and selectivity. Filtered Noise Field (FNF) technology is found to be an excellent means for achieving lower detection limits through selective storage of the ion(s) of interest during ionization. Figures of merit including typical sample sizes, detection limits, and response times are provided. The results indicate the potential of these techniques for atmospheric assessments, the High Speed Research Program, and advanced life support monitoring applications for NASA.

Palmer, Peter T.↗

Detecting Organic Compounds in Martian Soil Analogues Using Gas Chromatography Mass Spectrometry

One of the primary objectives of the 1976 Viking missions was to determine whether organic compounds, possibly of biological origin, were present in the Martian surface soils. The Viking gas chromatography mass spectrometry (GCMS) instruments found no evidence for any organic compounds of Martian origin above a few parts per billion in the upper 10 cm of surface soil [l], suggesting the absence of a widely distributed Martian biota. However, Benner et d. have suggested that significant amounts of non-volatile organic compounds, possibly including oxidation products of bioorganic molecules (e.g. carboxylic acids) would not have been detected by the Viking GCMS [2]. Moreover, other key organic compounds important to biology, such as amino acids and nucleobases, would also likely have been missed by the Viking GCMS as these compounds require chemical derivatization to be stable in a GC column [3]. Recent pyrolysis experiments with a Mars soil analogue that had been innoculated with Escherichia coli bacteria have shown that amino acid decomposition products (amines) and nucleobases are among the most abundant products generated after pyrolysis of the bacterial cells [4,5]. At the part per billion level (Viking GCMS detection limit), these pyrolysis products generated from several million bacterial cells per gram of Martian soil would not have been detected by the Viking GCMS instruments [4]. Analytical protocols are under development for upcoming in situ lander opportunities to target several important biological compounds including amino acids and nucleobases. For example, extraction and chemical derivatization techniques [3] are being adapted for space flight use to transform reactive or fragile molecules that would not have been detected by the Viking GCMS instruments, into species that are sufficiently volatile to be detected by GCMS. Recent experiments carried out at NASA Goddard have shown that using this derivatization technique all of the targeted compounds mentioned above can be separated on a GC column and detected by MS at sub-picomole (< 10(exp -l2 mole) levels. With these methods, the detection limit for amino acids, carboxylic acids and nucleobases is several orders of magnitude more sensitive than the Viking GCMS instruments for these compounds. Preliminary results using this analytical technique on a variety of Martian soil analogues will be presented.

Glavin, D. P.↗

Near Infrared Cavity Ring-Down Spectroscopy for Isotopic Analyses of CH4 on Future Martian Surface Missions

A compact Near Infrared Continuous Wave Cavity Ring-Down Spectrometer (near-IR-cw-CRDS) was developed as a candidate for future planetary surface missions. The optical cavity was made of titanium with rugged quartz windows to protect the delicate super cavity from the harsh environmental changes that it would experience during space flight and a Martian surface mission. This design assured the long-term stability of the system. The system applied three distributed feedback laser diodes (DFB-LD), two of which were tuned to the absorption line peaks of (sup 12)CH4 and (sup 13)CH4 at 6046.954 inverse centimeters and 6049.121 inverse centimeters, respectively. The third laser was tuned to a spectral-lines-free region for measuring the baseline cavity loss. The multiple laser design compensated for typical baseline drift of a CRDS system and, thus, improved the overall precision. A semiconductor optical amplifier (SOA) was used instead of an Acousto-Optic Module (AOM) to initiate the cavity ring-down events. It maintained high acquisition rates such as AOM, but consumed less power. High data acquisition rates combined with improved long-term stability yielded precise isotopic measurements in this near-IR region even though the strongest CH4 absorption line in this region is 140 times weaker than that of the strongest mid-IR absorption band. The current system has a detection limit of 1.4 times 10( sup –12) inverse centimeters for (sup 13)CH4. This limit corresponds to approximately 7 parts per trillion volume of CH4 at 100 Torrs. With no further improvements the detection limit of our current near IR-cw-CRDS at an ambient Martian pressure of approximately 6 Torrs (8 millibars) would be 0.25 parts per billion volume for one 3.3 minute long analysis.

portable nir crds↗

Rapid determination of radiostrontium in seawater samples

A new method for the determination of radiostrontium in seawater samples has been developed at the Savannah River National Laboratory (SRNL) that allows rapid preconcentration and separation of strontium and yttrium isotopes in seawater samples for measurement. The new SRNL method employs a novel and effective pre-concentration step that utilizes a blend of calcium phosphate with iron hydroxide to collect both strontium and yttrium rapidly from the seawater matrix with enhanced chemical yields. The pre-concentration steps, in combination with rapid Sr Resin and DGA Resin cartridge separation options using vacuum box technology, allow seawater samples up to 10 liters to be analyzed. The total 89 Sr + 90 Sr activity may be determined by gas flow proportional counting and recounted after ingrowth of 90 Y to differentiate 89 Sr from 90 Sr. Gas flow proportional counting provides a lower method detection limit than liquid scintillation or Cerenkov counting and allows simultaneous counting of samples. Simultaneous counting allows for longer count times and lower method detection limits without handling very large aliquots of seawater. Seawater samples up to 6 liters may be analyzed using Sr Resin for 89 Sr and 90 Sr with a Minimum Detectable Activity (MDA) of 1-10 mBq/L, depending on count times. Seawater samples up to 10 liters may be analyzed for 90 Sr using a DGA Resin method via collection and purification of 90 Y only. If 89 Sr and other fission products are present, then 91 Y (beta energy 1.55 MeV, 58.5 day half-life) is also likely to be present. 91 Y interferes with attempts to collect 90 Y directly from the seawater sample without initial purification of Sr isotopes first and 90 Y ingrowth. The DGA Resin option can be used to determine 90 Sr, and if 91 Y is also present, an ingrowth option with using DGA Resin again to collect 90 Y can be performed. An MDA for 90 Sr of <1 mBq/L for an 8 hour count may be obtained using 10 liter seawater sample aliquots.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

The quick and ultrasensitive determination of K in NaI using inductively coupled plasma mass spectrometry

A highly sensitive, novel and quick assay method utilizing inductively coupled plasma mass spectrometry was developed for the determination of K in NaI powders and NaI(Tl) scintillator crystals for use in ultralow background applications. The determination of K (viz. 40K), as well as Th and U and their daughters, is important in ultralow background detector materials to ensure incorporation of materials of sufficiently high radiopurity. Through the use of improved instrumentation, cool plasma operating conditions, and meticulously clean sample preparations, detection limits of 11 fg natK∙g-1 (or 341 pBq 40K∙kg-1) was attained for K in pure water. Detection limits in the sample matrix (i.e., NaI) were 0.529 ng natK∙g NaI-1 (or 16.4 Bq 40K∙kg NaI -1). A number of different precursor NaI powder samples and NaI(Tl) scintillator crystals were assayed for their K content. Determinations ranged from 0.757 – 31.4 ng natK∙g NaI-1. This method allows for the screening of materials to unprecedented levels in a fraction of the time compared to gamma counting techniques, providing a useful method for a more effective screening tool of K in ultralow background detector materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

2015 Long-Term Hydrologic Monitoring Program Sampling and Analysis Results Report for Project Rulison, Co

The U.S. Department of Energy (DOE) Office of Legacy Management conducted annual sampling at the Rulison, Colorado, Site for the Long-Term Hydrologic Monitoring Program (LTHMP) on May 20–22 and 27, 2015. Several of the land owners were not available to allow access to their respective properties, which created the need for several sample collection trips. This report documents the analytical results of the Rulison monitoring event and includes the trip report and the data validation package (Appendix A). The groundwater and surface water monitoring were shipped to the GEL Group Inc. laboratories for analysis. All requested analyses were successfully completed. Samples were analyzed for gamma-emitting radionuclides by high- resolution gamma spectrometry. Tritium was analyzed using two methods, the conventional tritium method, which has a detection limit on the order of 400 picocuries per liter (pCi/L), and the enriched method (for selected samples), which has a detection limit on the order of 3 pCi/L.

54 ENVIRONMENTAL SCIENCES↗