Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A new neutron time-of-flight detector for yield and ion-temperature measurements at the OMEGA Laser Facility

A new neutron time-of-flight (nTOF) detector for deuterium–deuterium (DD)-fusion yield and ion-temperature measurements was designed, installed, and calibrated for the OMEGA Laser Facility. This detector provides an additional line of sight for DD neutron yield and ion-temperature measurements for yields exceeding 1 × 10 10 with higher precision than existing detectors. The nTOF detector consists of a 90-mm-diam, 20-mm-thick BC-422 scintillator and a gated Photek photomultiplier tube (PMT240). The PMT collects scintillating light through the 20-mm side of the scintillator without the use of a light guide. There is no lead shielding from hard x rays in order to allow the x-ray instrument response function of the detector to be measured easily. Instead, hard x-ray signals generated in implosion experiments are gated out by the PMT. The design provides a place for glass neutral-density filters between the scintillator and the PMT to avoid PMT saturation at high yields. The nTOF detector is installed in the OMEGA Target Bay along the P8A sub-port line of sight at a distance of 5.3 m from the target chamber center. In addition to DD measurements, the same detector can be used to measure the neutron yield and ion temperature from deuterium–tritium (DT) implosion targets in the 5 × 10 10 to 2 × 10 12 yield range. Here, the design details and the calibration results of this nTOF detector for both D 2 and DT implosions on OMEGA will be presented.

47 OTHER INSTRUMENTATION↗

Super-Resolution Ptychography with Small Segmented Detectors

To overcome the spatial resolution limit set by aperture-limited diffraction in traditional scanning transmission electron microscopy, microscopists have developed ptychography enabled by iterative phase retrieval algorithms and high-dynamic-range pixel array detectors. Current detector designs are limited by the data rate off chip, so a high-pixel-count detector has a proportionally lower frame rate than the few-segment detectors used for differential phase contrast (DPC) imaging. This slower acquisition speed leads to heightened vulnerability to scan noise, drift, and potential sample damage. This creates opportunities for repurposing fast segmented detectors for ptychography by trading a reduction in reciprocal space pixels for an increase in real space pixels. Here, we explore a strategy of oversampling in real space and instead apply detector pixel upsampling during the reconstruction process. Further, we demonstrate the viability of achieving super-resolution ptychography on thin objects using only 2 × 2 detector pixels, surpassing the resolution of integrated DPC (iDPC) imaging. With optimization using simulated datasets and experiments on MoTe 2 /WSe 2 bilayer moiré superlattices, we achieved super-resolution ptychography reconstructions under rapid acquisition conditions (37.5 pA, 1 μs dwell time), yielding over 50% improvements in contrast and information limit compared to annular dark field and iDPC imaging on the same detectors.

2D materials↗

A Solenoid With Partial Yoke for the Dune Near Detector

The Deep Underground Neutrino Experiment (DUNE) at Fermilab is one the most challenging next-generation experiments in the field of neutrino physics. It will feature two detectors for a detailed study of neutrino oscillations using an unprecedentedly intense neutrino beam. The two detectors are a Near Detector located on the Fermilab site, 574 m away from the neutrino generation, and a Far Detector in South Dakota, 1300 km away. The Near Detector consists of three subdetectors, based on different technologies in order to achieve the best understanding of the neutrino beam. One key element of the Near Detector is a High Pressure Argon TPC surrounded by a calorimeter. This detector will need a 0.5 Tesla magnetic field transverse to the neutrino beam direction, with a 7 m diameter, 8 m long warm bore. A thin superconducting solenoid with a partial yoke, needed in order to minimise the amount of material along the path particles take crossing the different elements of the Near Detector is proposed. In this paper we present a detailed magnetic analysis and a preliminary study of the cooling, the cable and the mechanics for this magnet.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and validation of a cold load for characterization of cosmic microwave background stage 4 detectors

We present the design and validation of a variable temperature cryogenic blackbody source, hereinafter called a cold load, that will be used to characterize detectors to be deployed by cosmic microwave background stage 4 (CMB-S4), the next-generation ground-based cosmic microwave background (CMB) experiment. Although cold loads have been used for detector characterization by previous CMB experiments, this cold load has three innovative design features: (1) the ability to operate from the 1-K stage of a dilution refrigerator (DR), (2) a He3 gas-gap heat switch to reduce cooling time, and (3) the ability to couple small external optical signals to measure detector optical time constants under low optical loading. The efficacy of this design was validated using a 150-GHz detector array previously deployed by the Spider experiment. Thermal tests showed that the cold load can be heated to temperatures required for characterizing CMB-S4’s detectors without significantly impacting the temperatures of other cryogenic stages when mounted to the DR’s 1-K stage. In addition, optical tests demonstrated that external signals can be coupled to a detector array through the cold load without imparting a significant optical load on the detectors, which will enable measurements of the CMB-S4 detectors’ optical time constants.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The scintillator surface detector of the Pierre Auger observatory

Data collected so far by the Pierre Auger Observatory have enabled major advances in ultra-high energy cosmic ray physics and demonstrated that improved determination of masses of primary cosmic-ray particles, preferably on an event-by-event basis, is necessary for understanding their origin and nature. Improvement in primary mass measurements was the main motivation for the upgrade of the Pierre Auger Observatory, called AugerPrime. As part of this upgrade, scintillator detectors are added to the existing water-Cherenkov surface detector stations. By making use of the differences in detector response to the electromagnetic particles and muons between scintillator and water-Cherenkov detectors, the electromagnetic and muonic components of cosmic-ray air showers can be disentangled. Since the muonic component is sensitive to the primary mass, such combination of detectors provides a powerful way to improve primary mass composition measurements over the original Auger surface detector design. In this paper, the so-called Scintillator Surface Detectors are discussed, including their design characteristics, production process, testing procedure and deployment in the field.

Detector design and construction technologies and ↗

Cryogenics and purification systems of the ICARUS T600 detector installation at Fermilab

This paper describes the cryogenic and purification systems of the ICARUS T600 detector in its present implementation at the Fermi National Laboratory, Illinois, U.S.A. The ICARUS T600 detector is made of four large Time Projection Chambers, installed in two separate containers of about 275 m 3 each. The detector uses liquid argon both as target and as active medium. For the correct operation of the detector, the liquid argon must be kept in very stable thermal conditions and the contamination of electronegative impurities must be consistently kept at the level of small fractions of parts per billion. The detector was previously operated in Italy, at the INFN Gran Sasso Underground Laboratory (LNGS), in a three-year run on the CERN to LNGS Long Baseline Neutrino Beam. For its operation on the Booster and NuMI neutrino beams at Fermilab, for the search of sterile neutrinos and measurements of neutrino-argon cross sections, the detector was moved from Gran Sasso to CERN for the upgrades required for operation at shallow depth with high intensity neutrino beams. The liquid argon containers, the thermal insulation and all the cryogenic equipment have been completely re-designed and rebuilt, following the schemes of the previous installation in Gran Sasso. The detector and all the equipment have been transported to Fermilab, where they have been installed, tested and recently put into operation. The work described in this paper has been conducted as a joint responsibility of CERN and Fermilab with the supervision provided by the ICARUS Collaboration. Design, installation, testing, commissioning and operation are the result of a common effort of CERN, Fermilab and INFN groups.

Cryogenic detectors↗

BICEP Array: 150 GHz Detector Module Development

The Background Imaging of Cosmic Extragalactic Polarization (BICEP)/Keck (BK) collaboration is currently leading the quest for the highest-sensitivity measurements of the polarized cosmic microwave background (CMB) anisotropies on a degree scale with a series of cryogenic telescopes, of which BICEP Array (BA) is the latest Stage-3 upgrade with a total of ~ 32,000 detectors. The instrument comprises 4 receivers spanning 30–270 GHz, with the low-frequency 30/40 GHz deployed to the South Pole Station in late 2019. The full complement of receivers is forecast to set the most stringent constraints on the tensor-to-scalar ratio r. Building on these advances, the overarching small-aperture telescope concept is already being used as the reference for further Stage-4 experiment design. This paper describes the development of the BICEP Array 150 GHz detector module and its fabrication requirements, with highlights on the high-density time division multiplexing (TDM) design of the cryogenic circuit boards. The low-impedance wiring required between the detectors and the frst stage of superconducting quantum interference device amplifers is crucial to maintaining a stable bias current on the detectors. Here, a novel multilayer FR4 Printed Circuit Board with superconducting traces, capable of reading out up to 648 detectors, is detailed along with its validation tests. An ultra-high-density TDM detector module concept we developed for a CMB-S4-like experiment that allows up to 1920 detectors to be read out is also presented. TDM has been chosen as the detector readout technology for the Cosmic Microwave Background Stage-4 (CMB-S4) experiment based on its proven low-noise performance, predictable costs, and overall maturity of the architecture. The heritage for TDM is rooted in mm- and sub-mm-wave experiments dating back 20 years and has since evolved to support a multiplexing factor of 64x in Stage-3 experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

3x3 array module of 8×8×32 mm 3 position-sensitive virtual frisch-grid CdZnTe detectors for imaging and spectroscopy of cosmic gamma-rays

Here, we evaluated the performance of the 3x3 array of 32-mm long position-sensitive virtual Frisch-grid (VFG) CdZnTe (CZT) detectors read out by the IDEAS GDS-100 data acquisition system. The array is a mechanically solid module designed for integration into a large effective area gamma-ray telescope proposed for imaging and spectroscopy of cosmic gamma-rays. The array employs the bar-shaped 8x8x32 mm 3 CZT crystals which recently became available from Redlen Technologies, Inc. and Kromek-eV Group PLC at affordable costs. The waveform sampling IDE3421 application-specific integrated circuit (ASIC), developed by the University of Michigan and IDEAS for CZT pixel detectors, was adapted to capture the signals from the array's VFG detectors. We showed good spectral performance of the Redlen detectors with an energy resolution of <1% FWHM at 662 keV and slightly poorer performance of the Kromek-eV detectors with a resolution of <2% measured at a reduced temperature of 13 °C. By testing the same detectors as single devices using hybrid charge-sensitive preamplifiers, we demonstrated improved energy resolutions at a normal temperature of ~25°C: <1% and 1.3-1.7%, respectively. However, the Kromek-eV detectors did not perform as well as the Redlen ones. We explained this by the space charge formation (polarization) decreasing the electric field and the electron drift times. The polarization was likely caused by the high injections of holes from the anode contacts. The absence of polarization in Redlen detectors suggested that the quality of the contacts might have played a role in this case.

47 OTHER INSTRUMENTATION↗

Response of a high-pressure 4 He scintillation detector to nuclear recoils up to 9 MeV

Helium-4-based scintillation detector technology is emerging as a strong alternative to pulse-shape discrimination-capable organic scintillators for fast neutron detection and spectroscopy, particularly in extreme gamma-ray environments. The 4 He detector is intrinsically insensitive to gamma radiation, as it has a relatively low cross-section for gamma-ray interactions, and the stopping power of electrons in the 4 He medium is low compared to that of 4 He recoil nuclei. Consequently, gamma rays can be discriminated by simple energy deposition thresholding instead of the more complex pulse shape analysis. The energy resolution of 4 He scintillation detectors has not yet been well-characterized over a broad range of energy depositions, which limits the ability to deconvolve the source spectra. In this work, an experiment was performed to characterize the response of an Arktis S670 4 He detector to nuclear recoils up to 9 MeV. The 4 He detector was positioned in the center of a semicircular array of organic scintillation detectors operated in coincidence. Deuterium–deuterium and deuterium–tritium neutron generators provided monoenergetic neutrons, yielding geometrically constrained nuclear recoils ranging from 0.0925 to 8.87 MeV. The detector response provides evidence for scintillation linearity beyond the previously reported energy range. Finally, the measured response was used to develop an energy resolution function applicable to this energy range for use in high-fidelity detector simulations needed by future applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MeV-scale performance of water-based and pure liquid scintillator detectors

This paper presents studies of the performance of water-based liquid scintillators (WbLS) in both 1-kt and 50-kt detectors. In this work, performance is evaluated in comparison to both pure water Cherenkov detectors and a nominal model for pure scintillator detectors. Performance metrics include energy, vertex, and angular resolution, along with a metric for the ability to separate the Cherenkov from the scintillation signal as being representative of various particle identification capabilities that depend on the Cherenkov/scintillation ratio. We also modify the time profile of scintillation light to study the same performance metrics as a function of rise and decay time. We go on to interpret these results in terms of their impact on certain physics goals, such as solar neutrinos and the search for Majorana neutrinos. This work supports and validates previous results, and the assumptions made therein, and serves as a significant stepping stone to complete detector design studies by using a more detailed detector model and full reconstruction, with a primarily data-driven optical model, and fewer model assumptions. With this model, a high-coverage 50-kt detector achieves better than 10 (1)% precision on the flux of neutrinos from the Carbon-Nitrogen-Oxygen cycle with a water-based liquid scintillator (pure LS) target in five years of data taking. A 1-kt LS detector, with a conservative 50% fiducial volume of 0.5 kt, can achieve better than 5% detection. A liquid scintillator detector has sensitivity into the normal hierarchy region for Majorana neutrinos with half-life sensitivity of $T^{0νββ}_{1/2}$ > 1.4 × 10 28 years at 90% C.L. for 10 years of data taking with a Te-loaded target.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cryogenic Detector Development for SuperCDMS

The dark matter (DM) problem is currently one of the most pressing issues facing physics. This thesis presents some of my work and contributions to the detectors employed by the Super Cryogenic Dark Matter Search (SuperCDMS), one of the many experiments currently investigating DM. First, we present an overview of astrophysical and cosmological observations to give insight into our current understanding of DM and its role in the universe. Some potential particle DM candidates are also discussed. Then we describe the SuperCDMS experiment and relevant detector technologies. We go into particular detail in discussing the phonon sensors, deriving the relationships that define their fundamental working principles and describing their practical deployment. We also discuss the main noise contributions to the phonon sensors which can limit experimental sensitivity. We then present some work related to reconstruction of event position in the detectors, including new analysis techniques and a n ovel cryogenic calibration source mover we have developed and tested. We also present tests of improving experimental scalability by increasing individual detector masses using the largest-diameter cryogenic Si detectors yet operated. We present first experimental results from the novel use of $(n,\gamma)$ processes to calibrate the low energy nuclear recoil energy scale. This work is essential to understand how DM-nuclear interactions will manifest in semiconductor detectors. We also take a short look at the newest, most sensitive detectors currently operated by SuperCDMS and discuss how they are allowing new insights into critical physics processes in all SuperCDMS detectors. Finally, we demonstrate how some of the various improvements discussed in this work can improve the experimental reach of the next generation of SuperCDMS at SNOLAB.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Near Detector Selection for Neutral Current Disappearance Search at the Short-Baseline Neutrino Program

Various short baseline neutrino experiments observe anomalies that challenge the three-flavor neutrino oscillation model, consistent with a hypothetical “sterile” neutrino that does not interact via the weak force. This poster presents a near detector event selection at the Short-Baseline Near Detector (SBND), developed for the first search for neutral current (NC) disappearance at short-baseline experiments. NC disappearance provides ``smoking gun” insight into the sterile neutrino question because NC interactions are equally sensitive to all three active neutrinos, meaning any change in the NC interaction rate between near and far detectors cannot be explained by oscillations among known flavor states. This analysis focuses on the NC1p topology, the most common NC interaction type at the Short-Baseline Neutrino (SBN) Program. NC topologies are inherently challenging due to their low light yield and the absence of an outgoing charged lepton, which complicates identification and leads to poor energy reconstruction as the outgoing neutrino carries away a large portion of the neutrino’s initial energy. This work presents an NC1p event selection at the near detector, highlighting SBND’s impressive detector capabilities, including trigger efficiency studies. Combined with a novel kinematic energy reconstruction technique leveraging the detector’s outstanding hadronic detail, this analysis establishes a robust near detector foundation to target an NC disappearance measurement consistent with the 3$+$1 sterile neutrino model. This SBND selection will soon be combined with the far detector to conduct an NC disappearance search, providing unique insight and complementary information to traditional charged current searches and advancing the SBN Program’s goal to resolve the sterile neutrino question, including 3$+$1 searches and beyond.

Nicole Pallat, Nicole Pallat [Minnesota U.] (ORCID↗

A bismuth germanate-shielded mercuric iodide X-ray detector for space applications

The development of HgI2 for solid state X-ray detector applications over the past decade was carried out in connection with the ability of the crystal to operate as a detector at room temperature. In order to achieve the lowest background possible for HgI2 detectors in a space-like environment (balloon and/or satellite altitudes), attention was given to the design of a shielding system which actively vetoes nonaperture events such as gamma rays and charged particles that can mimic signal X-rays by partial deposition of energy in the main detector. The detector system consists of two HgI2 detectors mounted back to back and operated in anticoincidence. The two detectors are placed inside a bismuth germanate scintillating shield along with two hybrid charge-sensitive preamps. Monte Carlo simulations of detector performance are discussed.

Vallerga, J. V.↗

ISO/LWS: Detector status

The aim of the long wavelength spectrometer (LWS) of the Infrared Space Observatory is to perform spectrometry in the wavelength range 45 to 200 microns using two resolution modes. The resolution will be around 200 in the medium resolution mode while it will reach 10(exp 4) in the high resolution mode. The sensitivity of this instrument will be close to 10(exp -18) W/sq. root Hz. A schematic view of the focal plane unit is presented. The detectors divide the wavelength range into ten spectral channels. The spectral range and position of each detector is indicated. Each detector will cover approximately a spectral bandwidth sufficient to allow for a 50 percent redundancy in the case of detector failure. There are three types of detectors. SW1 is a Ge:Be photoconductor covering the 45 to 55 micron region. LW1, SW2, SW3, SW4, SW5 are unstressed Ge:Ga photoconductors which cover the 50 to 120 micron region. LW2, LW3, LW4, LW5 are uniaxially stressed Ge:GA photoconductors covering the range from 100 to 200 microns. The stress applied to each detector will be adjusted in order to get the peak response in the corresponding wavelength range, and to minimize the dark current of the shorter wavelength stressed detectors. Stressed and unstressed detectors are located alternatively in order to receive the first and second order of the diffracted beam.

Lenaour, C.↗

Effects of ionizing radiation on cryogenic infrared detectors

The Diffuse Infrared Background Experiment (DIRBE) is one of three experiments to be carried aboard the Cosmic Background Explorer (COBE) satellite scheduled to be launched by NASA on a Delta rocket in 1989. The DIRBE is a cryogenic absolute photometer operating in a liquid helium dewar at 1.5 K. Photometric stability is a principal requirement for achieving the scientific objectives of this experiment. The Infrared Astronomy Satellite (IRAS), launched in 1983, which used detectors similar to those in DIRBE, revealed substantial changes in detector responsivity following exposure to ionizing radiation encountered on passage through the South Atlantic Anomaly (SAA). Since the COBE will use the same 900 Km sun-synchronous orbit as IRAS, ionizing radiation-induced performance changes in the detectors were a major concern. Here, ionizing radiation tests carried out on all the DIRBE photodetectors are reported. Responsivity changes following exposure to gamma rays, protons, and alpha particle are discussed. The detector performance was monitored following a simulated entire mission life dose. In addition, the response of the detectors to individual particle interactions was measured. The InSb photovoltaic detectors and the Blocked Impurity Band (BIB) detectors revealed no significant change in responsivity following radiation exposure. The Ge:Ga detectors show large effects which were greatly reduced by proper thermal annealing.

Moseley, S. H.↗

Proton-induced radiation damage in germanium detectors

High-purity germanium (HPGe) detectors will be used in future space missions for gamma-ray measurements and will be subject to interactions with energetic particles. To simulate this process, several large-volume n-type HPGe detectors were incrementally exposed to a particle fluence of up to 10 to the 8th protons/sq cm (proton energy: 1.5 GeV) at different operating temperatures (90 to 120 K) to induce radiation damage. Basic scientific and engineering data on detector performance were collected. During the incremental irradiation, the peak shape produced by the detectors showed a significant change from a Gaussian shape to a broad complex structure. After the irradiation, all detectors were thoroughly characterized by measuring many parameters. To remove the accumulated radiation damage, the detectors were stepwise-annealed at temperatures below 110 C, while kept in their specially designed cryostats. This study shows that n-type HPGe detectors can be used in charged-particle environments as high-energy resolution devices until a certain level of radiation damage is accumulated and that the damage can be removed at moderate annealing temperatures and the detector returned to operating condition.

Brueckner, J.↗

The Zero-Degree Detector System

We will report on a detector system used for accelerator measurement of nuclear fragmentation cross sections. This system consists of two detector planes, each carrying a ring of 8 detectors. Each detector has 64 pads. These two detector planes are arranged facing each other so that the matching detector pads on each plane form a two element charged particle telescope. Each of these telescopes is capable of determining the elemental identity of nuclear fragments passing through it. The system is used to measure light fragment production in the presence of heavier fragments. We will present a detailed discussion of the 64-pad detector design, the substrate design. The front-end electronics used to read out the signals is based on a custom VLSI chip developed for the Advanced Thin Ionization Calorimeter experiment which has been flown successfully twice in Antarctica. Each of these chips has 16 channels and each channel consists of a charge-sensitive preamplifier followed by a shaping amplifier and a track-and-hold circuit. The track-and-hold circuits are connected via a multiplexer to an output line driver. This allows the held signals to be presented, one-by-one via a common data line to a analog-to-digital converter. Because the output line driver can be placed in a high input impedance state when not in use, it is possible to daisy-change many chips on the same common data line. The front-end electronics and data readout scheme will be discussed in detail. The Zero Degree Detector has been used in several accelerator experiments conducted at the NASA Space Radiation Laboratory and the Alternating Gradient Synchrotron at Brookhaven National Laboratory as well as at the HIMAC accelerator in Japan. We will show examples of data taken at these accelerator runs to demonstrate how the system works.

Adams, James H.↗

X-Ray Detector Research at MSFC for Space Applications

NASA's Vision for Space Exploration has specific goals aimed at exploring the Solar System. This vision, under presidential mandate includes landing humans on the moon before the end of the next decade, paving the way for eventual journeys to Mars and beyond. The first missions to the moon will be in the form of both Orbiters and Landers, with the goal of paving the way for human return. One of the instruments we are currently working on,in collaboration with Brookhaven National Laboratory, is a lunar orbiter fluorescent x-ray spectrometer to finely map the light elements (down to Carbon) on surface of the moon. Funded NASA s Planetary Instrument Definition and Development Program the instrument is based on silicon drift detector arrays read out by custom ASICs. These offer the promise of high spectral resolution, necessary for resolving weak lines against a strong background continuum, and very low power requirements, necessary for large areas (greater than 500 square centimeters) required for future lunar missions. Further, the inherent radiation hardness of these detectors makes them ideal candidates for exploring the Jovian system, where the harsh radiation environment from Jupiter s radiation belts creates unfavorable detector conditions. Looking beyond our solar system, in the hard x-ray regime (20-80keV.), we are studying Cadmium-Zinc-Telluride pixilated detectors as feasible candidates for focal plane detectors of a hard x-ray telescope. This energy region bridges the gap between thermal and non-thermal x-ray emission from astronomical sources, will allow us to better understand supernovae nucleosynthesis (such as through the Ti-44 lines at 68keV and 78keV), Active Galactic Nuclei and other compact objects, more completely. The detectors that we are characterizing are 2mm in thickness and are pixilated with a 16x16 array of 300 micrometer pitch pixels (50micometer gap). These detectors are designed at Rutherford Appleton Laboratory, material is from eV Products, and polymer flip-chip assembly was performed by a commercial vendor. An energy resolution of 2.0% at 60keV (or better) should allow us to sufficiently distinguish lines of interest from background continuum, and the detector spatial resolution should be fine enough to over-sample the focal spot from the x-ray focusing optics by about a factor of two. Full technical details of these developments will be presented.

Gaskin, Jessica↗