Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

BigPanDA: PanDA Workload Management System and its Applications beyond ATLAS

Modern experiments collect peta-scale volumes of data and utilize vast, geographically distributed computing infrastructure that serves thousands of scientists around the world. Requirements for rapid, near real-time data processing, fast analysis cycles and need to run massive detector simulations to support data analysis pose special premium on efficient use of available computational resources. A sophisticated Workload Management System (WMS) is needed to coordinate the distribution and processing of data and jobs in such environment. The ATLAS experiment at CERN uses PanDA (Production and Data Analysis) Workload Management System for managing the workflow for all data processing on over 150 data centers. While PanDAcurrently uses more than 250,000 cores with a peak performance of 0.3 petaFLOPS, it runs around 2 million jobs per day on hundreds of Grid sites and serving thousands of ATLAS users. In 2017 about 1.5 exabytes of data were processed with PanDA.In 2012 BigPanDA project project was started with aim to introduce new types of computing resources into ATLAS computing infrastructure, but also to offering PanDA features to different data-intensive applications for projects and experiments outside of ATLAS and High-Energy and Nuclear Physics. In this article we will present accomplishments and discuss possible directions for future work.

Svirin, Pavlo↗

MEASUREMENT OF THE CHARGED-CURRENT INCLUSIVE ELECTRON NEUTRINO AND ELECTRON ANTINEUTRINO CROSS SECTION USING THE MICROBOONE DETECTOR IN THE NUMI BEAM

Detection of electron neutrino appearance is the process by which modern neutrino experiments seek to answer the open questions in neutrino physics: CP-violation in the neutrino sector, the neutrino mass ordering, and sterile neutrino oscillations. To date, only three measurements of electron neutrino cross sections have been performed. The analysis presented in this thesis describes the extraction of the first charged-current inclusive $\nu_e$ + $\bar{\nu}_e$ cross section on argon. This calculation was performed with data collected by the MicroBooNE liquid argon time projection chamber using neutrinos from the Neutrino Main Injector (NuMI) beam located at the Fermi National Accelerator Laboratory. Extraction of this cross section is enabled by the first fully-automated inclusive selection of $\nu_e$ + $\bar{\nu}_e$ charged-current interactions in a liquid argon time projection chamber, which provided the largest sample of $\nu_e$ + $\bar{\nu}_e$ charged-current interactions ever observed in liquid argon. The selection utilises the signature capabilities of liquid argon, such as distinguishing electron-like and photon-like electromagnetic showers using their charge-deposition profiles (dE/dx). The evaluation of systematic effects influencing the final cross section, including detector simulation and flux simulation uncertainties, which have been applied for the first time to a MicroBooNE analysis using neutrinos from the NuMI beam, is also presented. The total impact of all systematic and statistical effects results in a 38.44\% uncertainty on the flux integrated cross section, giving $\sigma_{\nu_{e}~+~\bar{\nu}_e} = 4.67 \pm 1.01 \textrm{(stat)} \pm 1.48 \textrm{(sys)} \times 10^{-39}$ cm$^{2}$ per nucleon as the final result, which is in agreement with theoretical predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Semi-inclusive Neutral Current Neutral Pion Production Selection at the NOvA (NuMI Off-axis Electron Neutrino Appearance) Near Detector Using Prong Level Convolutional Neural Networks

The NONA neutrino experiment based in Fermilab is designed to measure ν µ →ν e neutrino oscillations. This experiment will give us insight into the properties of massive neutrinos. Neutral current (NC) ν µ,e neutral pion production events can mimic the ν µ →ν e oscillation signal and therefore are an important background for NONA to understand. Neutral pions decay into two photons which can fake a single electron shower (νe appearance signal) in two ways: either the 2 photons can merge together or one of them may escape detection. In order to constrain this background, NONA utilizes the Near Detector to measure neutral current π 0 neutrino interactions. In this analysis, neutrino-Nucleus (ν µ →N) NC π 0 interactions with total pion energy greater then 0.3 GeV are studied by selecting two prong events with two final state photons as determined by prong based Convolutional Visual Networks (CVN). The analysis is performed on 3.54x10 21 Protons On Target (POT) of NONA Near Detector simulated data and compared to 8.09x10 20 POT of data. Optimization of the selection based on fractional cross-section uncertainty and an initial energy resolution study of the final sample are presented. The final 2 prong selection using prong based CVN gave a purity of 74%, selection efficiency of ~ 1.8%, and an expected (NC) ν µ,e neutral pion cross section of ~ 15.2%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A modified Monte Carlo 'local importance function transform' method

The Local Importance Function Transform (LIFT) method uses an approximation of the contribution transport problem to bias a forward Monte-Carlo (MC) source-detector simulation [1-3]. Local (cell-based) biasing parameters are calculated from an inexpensive deterministic adjoint solution and used to modify the physics of the forward transport simulation. In this research, we have developed a new expression for the LIFT biasing parameter, which depends on a cell-average adjoint current to scalar flux (J{sup *}/{phi}{sup *}) ratio. This biasing parameter differs significantly from the original expression, which uses adjoint cell-edge scalar fluxes to construct a finite difference estimate of the flux derivative; the resulting biasing parameters exhibit spikes in magnitude at material discontinuities, causing the original LIFT method to lose efficiency in problems with high spatial heterogeneity. The new J{sup *}/{phi}{sup *} expression, while more expensive to obtain, generates biasing parameters that vary smoothly across the spatial domain. The result is an improvement in simulation efficiency. A representative test problem has been developed and analyzed to demonstrate the advantage of the updated biasing parameter expression with regards to solution figure of merit (FOM). For reference, the two variants of the LIFT method are compared to a similar variance reduction method developed by Depinay [4, 5], as well as MC with deterministic adjoint weight windows (WW). (authors)

97 MATHEMATICS AND COMPUTING↗

MeVPrtl: An Event Generator for Dark Sector Particles in the Short-Baseline Neutrino Program

MeVPrtl is a modular event generator of beyond the Standard Model (BSM) physics particles developed for use in the Short-Baseline Neutrino (SBN) Program. A large class of BSM physics models predict that new particles could be produced in the intense Booster Neutrino Beam (BNB) and Neutrinos at the Main Injector (NuMI) beams at Fermilab, travel to the SBN Program detectors, and decay into Standard Model (SM) particles. These new physics models are motivated by dark matter, the neutrino mass scale, and a solution to the strong CP problem. MeVPrtl provides an interface to implement the overlapping phenomenology of these models, and to connect them with meson flux inputs and object outputs used by the SBN Program's LArSoft-based detector simulation. Implementations for the Higgs portal, heavy neutral lepton, and heavy QCD axion models exist within MeVPrtl. In this paper these implementations and their validation, as well as details of the MeVPrtl interface, are specified.

Abratenko Ao, P.↗

A fast method for optical simulation of flood maps of light-sharing detector modules

Optical simulation of the detector module level is highly desired for Position Emission Tomography (PET) system design. Commonly used simulation toolkits such as GATE are not efficient in the optical simulation of detector modules with complicated light-sharing configurations, where a vast amount of photons need to be tracked. Here, we present a fast approach based on a simplified specular reflectance model and a structured light-tracking algorithm to speed up the photon tracking in detector modules constructed with polished finish and specular reflector materials. We also simulated conventional block detector designs with different slotted light guide patterns using the new approach and compared the outcomes with those from GATE simulations. And while the two approaches generated comparable flood maps, the new approach was more than 200–600 times faster. The new approach has also been validated by constructing a prototype detector and comparing the simulated flood map with the experimental flood map. The experimental flood map has nearly uniformly distributed spots similar to those in the simulated flood map. In conclusion, the new approach provides a fast and reliable simulation tool for assisting in the development of light-sharing-based detector modules with a polished surface finish and using specular reflector materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Numerical integration of detector response functions via Monte Carlo simulations

Calculations of detector response functions are complicated because they include the intricacies of signal creation from the detector itself as well as a complex interplay between the detector, the particle-emitting target, and the entire experimental environment. As such, these functions are typically only accessible through time-consuming Monte Carlo simulations. Furthermore, the output of thousands of Monte Carlo simulations can be necessary in order to extract a physics result from a single experiment. Here we describe a method to obtain a full description of the detector response function using Monte Carlo simulations. We also show that a response function calculated in this way can be used to create Monte Carlo simulation output spectra a factor of ~1000× faster than running a new Monte Carlo simulation. A detailed discussion of the proper treatment of uncertainties when using this and other similar methods is provided as well. Here, this method is demonstrated and tested using simulated data from the Chi-Nu experiment, which measures prompt fission neutron spectra at the Los Alamos Neutron Science Center.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulations of Material-Dependent Detector Responses for Airborne Gamma-Ray Spectroscopy

The aim of this work is to create a library of predicted detector responses used for real-time background estimation during airborne gamma-ray spectroscopy. The simulated spectra are a function of naturally occurring radioactive potassium, uranium, and thorium (KUT) and radioactive daughter products which are present in terrestrial-based materials. Self-attenuation within these materials varies, such that the gamma spectra emitted from the surfaces can differ, despite all having KUT origins. This study also compared various simulated detector responses among materials to determine if some could be accurately scaled from another across reasonable helicopter altitudes and orientations, relative to the ground. Results show that materials with comparable sample thicknesses can be scaled consistently across altitude. This work allows for efficient background estimation via aggregation of simulated detector responses in real time.

radioactive potassium, uranium, and thorium, KUT, ↗

Comparison of simulated and experimentally measured detector impulse responses to pulsed x-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-toend performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of Simulated and Experimentally Measured Detector Impulse Responses to Pulsed X-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-to-end performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cone beam breast CT with a high pitch (75 μm), thick (500 μm) scintillator CMOS flat panel detector: Visibility of simulated microcalcifications

Purpose: To measure and investigate the improvement of microcalcification (MC) visibility in cone beam breast CT with a high pitch (75 μm), thick (500 μm) scintillator CMOS/CsI flat panel detector (Dexela 2923, Perkin Elmer).Methods: Aluminum wires and calcium carbonate grains of various sizes were embedded in a paraffin cylinder to simulate imaging of calcifications in a breast. Phantoms were imaged with a benchtop experimental cone beam CT system at various exposure levels. In addition to the Dexela detector, a high pitch (50 μm), thin (150 μm) scintillator CMOS/CsI flat panel detector (C7921CA-09, Hamamatsu Corporation, Hamamatsu City, Japan) and a widely used low pitch (194 μm), thick (600 μm) scintillator aSi/CsI flat panel detector (PaxScan 4030CB, Varian Medical Systems) were also used in scanning for comparison. The images were independently reviewed by six readers (imaging physicists). The MC visibility was quantified as the fraction of visible MCs and measured as a function of the estimated mean glandular dose (MGD) level for various MC sizes and detectors. The modulation transfer functions (MTFs) and detective quantum efficiencies (DQEs) were also measured and compared for the three detectors used.Results: The authors have demonstrated that the use of a high pitch (75 μm) CMOS detector coupled with a thick (500 μm) CsI scintillator helped make the smaller 150–160, 160–180, and 180–200 μm MC groups more visible at MGDs up to 10.8, 9, and 10.8 mGy, respectively. It also made the larger 200–212 and 212–224 μm MC groups more visible at MGDs up to 7.2 mGy. No performance improvement was observed for 224–250 μm or larger size groups. With the higher spatial resolution of the Dexela detector based system, the apparent dimensions and shapes of MCs were more accurately rendered. The results show that with the aforementioned detector, a 73% visibility could be achieved in imaging 160–180 μm MCs as compared to 28% visibility achieved by the low pitch (194 μm) aSi/CsI flat panel detector. The measurements confirm that the Hamamatsu detector has the highest MTF, followed by the Dexel detector, and then the Varian detector. However, the Dexela detector, with its thick (500 μm) CsI scintillator and low noise level, has the highest DQE at all frequencies, followed by the Varian detector, and then the Hamamatsu detector. The findings on the MC visibility correlated well with the differences in MTFs, noise power spectra, and DQEs measured for these three detectors.Conclusions: The authors have demonstrated that the use of the CMOS type Dexela detector with its high pitch (75 μm) and thick (500 μm) CsI scintillator could help improve the MC visibility. However, the improvement depended on the exposure level and the MC size. For imaging larger MCs or scanning at high exposure levels, there was little advantage in using the Dexela detector as compared to the aSi type Varian detector. These findings correlate well with the higher measured DQEs of the Dexela detector, especially at higher frequencies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of a Detector of Visible and Near-IR Electromagnetic Radiation Based on Artificial Diamond

A method for calculation of the I–V characteristic is proposed for a detector of visible and near-IR electromagnetic radiation based on artificial diamond with allowance for vertical flow of electric current. The method can be used when the free-path length of carriers in diamond is less than the scale of variations in the concentration of carriers. The method is used to determine the following detector characteristics: the dependence of current on voltage, distribution of carrier concentration, and electric potential for a particular variant of a photodetector based on polycrystalline diamond film consisting of nanosized single crystals doped with boron.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The fast simulation of the CMS detector at LHC

The CMS collaboration has developed a fast Monte Carlo simulation of the CMS detector with event production rates ~100 times faster than the GEANT4-based simulation, with nonetheless comparable accuracy for most of the physics objects typically considered in the analyses. We discuss basic technical principles of the CMS Fast Simulation and their implementation in the different components of the detector: the silicon tracker, the electromagnetic calorimeter, the hadronic calorimeter, the muon system, the Level 1 and the High Level Trigger. A few comparisons of the Fast Simulation results both with the GEANT4-based Full Simulation and with the LHC data are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reweighting simulated events using machine-learning techniques in the CMS experiment

Data analyses in particle physics rely on an accurate simulation of particle collisions and a detailed simulation of detector effects to extract physics knowledge from the recorded data. Event generators together with a GEANT -based simulation of the detectors are used to produce large samples of simulated events for analysis by the LHC experiments. These simulations come at a high computational cost, where the detector simulation and reconstruction algorithms have the largest CPU demands. This article describes how machine-learning (ML) techniques are used to reweight simulated samples obtained with a given set of parameters to samples with different parameters or samples obtained from entirely different simulation programs. The ML reweighting method avoids the need for simulating the detector response multiple times by incorporating the relevant information in a single sample through event weights. Results are presented for reweighting to model variations and higher-order calculations in simulated top quark pair production at the LHC. This ML-based reweighting is an important element of the future computing model of the CMS experiment and will facilitate precision measurements at the High-Luminosity LHC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and simulation of a muon detector to characterize geological overburden

This study presents the design, construction, and simulation of a mobile muon detector tailored for geological overburden characterization. The detector employs plastic scintillator paddles with silicon photomultipliers (SiPMs) and a QuarkNet data acquisition system, offering a portable solution suitable for remote field deployment. The simulator’s modular aluminum frame allows for adjustable geometry and directional sensitivity, while its battery system supports over a week of autonomous operation. Preliminary experimental tests confirmed that its muon flux measurements were consistent with theoretical expectations. A comprehensive simulation framework using Geant4 and CORSIKA was developed to model detector response and overburden effects. Analytical and Monte Carlo methods were used to assess quadrant resolution and infer muon directionality. This work lays the foundation for future overburden mapping and supports the development of reconstruction algorithms for geological applications.

72 - PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗