GT2023 Front Matter

Abstract The front matter for this proceedings is available by clicking on the PDF icon.

08 HYDROGEN↗

Optimizing transmit field inhomogeneity of parallel RF transmit design in 7T MRI using deep learning

Ultrahigh field (UHF) Magnetic Resonance Imaging (MRI) provides a higher signal-to-noise ratio and, thereby, higher spatial resolution. However, UHF MRI introduces challenges such as transmit radiofrequency (RF) field (B+1) inhomogeneities, leading to uneven flip angles and image intensity anomalies. These issues can significantly degrade imaging quality and its medical applications. This study addresses B+1 field homogeneity through a novel deep learning-based strategy. Traditional methods like Magnitude Least Squares (MLS) optimization have been effective but are time-consuming and dependent on the patient’s presence. Recent machine learning approaches, such as RF Shim Prediction by Iteratively Projected Ridge Regression and deep learning frameworks, have shown promise but face limitations like extensive training times and oversimplified architectures. We propose a two-step deep learning strategy. First, we obtain the desired reference RF shimming weights from multi-channel B+1 fields using random-initialized Adaptive Moment Estimation. Then, we employ Residual Networks (ResNets) to train a model that maps B+1 fields to target RF shimming outputs. Our approach does not rely on pre-calculated reference optimizations for the testing process and efficiently learns residual functions. Comparative studies with traditional MLS optimization demonstrate our method’s advantages in terms of speed and accuracy. The proposed strategy achieves a faster and more efficient RF shimming design, significantly improving imaging quality at UHF. This advancement holds potential for broader applications in medical imaging and diagnostics.

Lu, Zhengyi [Vanderbilt University]↗

Review of Ultrasonic Methods for Monitoring, Damage Detection, and Processing of Lithium-Ion Batteries Throughout Their Life Cycle

Lithium-ion batteries (LIBs) are the leading technology used in consumer electronics, electric vehicles, and grid-level electrochemical energy storage applications. The ever-increasing use of LIBs has highlighted a gap in understanding of their behavior throughout their life cycle. Current monitoring systems rely on electrical and sometimes temperature measurements to assess the internal state which limits information about complex electrochemical processes. In response, ultrasonic testing (UT) has shown promise for non-invasive assessment due to its ease of use and sensitivity to mechanical changes which are correlated with electrochemical changes within the battery. We summarize the research in UT methods applied to LIBs throughout their life cycle. We also discuss physics-based and data-driven modeling approaches used to interpret ultrasonic signals in the context of LIBs, with an emphasis on the existing challenge of establishing rigorous links between electrochemical behavior and elastic and poroelastic wave physics to gain insight regarding physical changes in the LIB that can be directly measured using UT. Finally, we discuss the challenges of implementing UT across the LIB life cycle and identify opportunities for further research. This review aims to provide helpful guidance to researchers and practitioners of UT in the growing field of UT for electrochemical battery systems.

25 ENERGY STORAGE↗

MHD-blob correlations in NSTX

This paper describes a study of the cross-correlations between edge fluctuations as seen in the gas puff imaging (GPI) diagnostic and low frequency coherent magnetic fluctuations (MHD) in H-mode plasmas in NSTX. The main new result was that large blobs in the SOL were significantly correlated with MHD activity the 3-6 kHz range in 21 of the 223 shots examined. There were also many other shots in which fluctuations in the GPI signal level and its peak radius Rpeak were correlated with MHD activity, but without any significant correlation of the MHD with large blobs. The structure and motion of the MHD is compared with that of the correlated blobs, and some possible theoretical mechanisms for the MHD-blob correlation are discussed.

blobs↗

Toward “super-scintillation” with nanomaterials and nanophotonics

Abstract Following the discovery of X-rays, scintillators are commonly used as high-energy radiation sensors in diagnostic medical imaging, high-energy physics, astrophysics, environmental radiation monitoring, and security inspections. Conventional scintillators face intrinsic limitations including a low extraction efficiency of scintillated light and a low emission rate, leading to efficiencies that are less than 10 % for commercial scintillators. Overcoming these limitations will require new materials including scintillating nanomaterials (“nanoscintillators”), as well as new photonic approaches that increase the efficiency of the scintillation process, increase the emission rate of materials, and control the directivity of the scintillated light. In this perspective, we describe emerging nanoscintillating materials and three nanophotonic platforms: (i) plasmonic nanoresonators, (ii) photonic crystals, and (iii) high-Q metasurfaces that could enable high performance scintillators. We further discuss how a combination of nanoscintillators and photonic structures can yield a “super scintillator” enabling ultimate spatio-temporal resolution while enabling a significant boost in the extracted scintillation emission.

Carr Delgado, Hamish↗

Science & Technology Review: April/May 2026 R&D 100 Winners Issue

At Lawrence Livermore National Laboratory, we focus on science and technology research to ensure our nation’s security. We also apply that expertise to solve other important national problems in energy, bioscience, and the environment. Science & Technology Review is published eight times a year to communicate, to a broad audience, the Laboratory’s scientific and technological accomplishments in fulfilling its primary missions. The publication’s goal is to help readers understand these accomplishments and appreciate their value to the individual citizen, the nation, and the world. Each year, the R&D 100 Awards recognize the top 100 innovations from a pool of international entries. Technologies developed at Lawrence Livermore earned four 2025 R&D 100 Awards, raising the Laboratory’s total to 186. A series of articles beginning on p. 4 describes each winning innovation: monolithic telescopes, the flexible imaging diffraction diagnostic for laser experiments, the in-air drop encapsulation apparatus, and the metaoptics-enabled large-scale 3D nanolithography platform.

36 MATERIALS SCIENCE↗

Doppler instrumentation for measuring blood velocity and flow

Doppler ultrasonic blood flowmeters are reviewed in detail. The importance of measurement accuracy for transcutaneous flowmeters and their clinical application is stressed. Doppler imaging was combined with conventional pulse echo imaging, and diagnostic information was extracted from flow signals. The range and extent of applications of Doppler instruments was also presented.

Gill, R. W.↗

A simulation and diagnostic study of water vapor image dry bands

Limited Area Mesoscale Prediction System model simulation and a special 3-hr radiosonde data set were used to investigate warm bands in the 6.7-micron water-vapor satellite imagery on March 6-7, 1982. It was found that the model reproduces major characteristics of the observed blackbody temperature, T(B), field. A 'development' dry image feature was found to occur in conjunction with an upper level shortwave trough, and an 'advective' feature was found associated with a polar jet streak. Both model and observed T(B) features were associated with vorticity maxima.

Muller, Bradley M.↗

Rocket engine plume diagnostics using video digitization and image processing - Analysis of start-up

Video digitization techniques have been developed to analyze the exhaust plume of the Space Shuttle Main Engine. Temporal averaging and a frame-by-frame analysis provide data used to evaluate the capabilities of image processing techniques for use as measurement tools. Capabilities include the determination of the necessary time requirement for the Mach disk to obtain a fully-developed state. Other results show the Mach disk tracks the nozzle for short time intervals, and that dominate frequencies exist for the nozzle and Mach disk movement.

Disimile, P. J.↗

The Ultra High Resolution XUV Spectroheliograph. II - Predicted performance

The phenomena to be studied with the Ultra-High Resolution XUV Spectroheliograph (UHRXS) which will be included into the instrumental load of the Space Station Freedom are discussed together with the characteristics of the nine multilayer Ritchey-Chretien telescopes constituting the UHRXS system. The telescopes will cover a spectral range from about 70 A to about 300 A. Each telescope will be able to isolate emission line multiplets excited over a narrow temperature range, providing images of diagnostic quality covering structures in the solar atmosphere ranging from T of about 50,000 K to 30,000,000 K. One of the nine UHRXS telescopes is configured as a coronagraph to allow observations to 6 solar radii beyond the solar limb. The paper presents an analysis of the expected sensitivity and resolving power of the UHRXS telescopes, and the diagnostic response of the various UHRXS instruments to structures in the solar atmosphere between 10,000 K and 100,000,000 K.

Walker, Arthur B. C., Jr.↗

Space medicine - Answering the challenge

The development of Space Station Freedom (SSF) Health Maintenance Facility (HMF) is discussed. Attention is given to HMF subsystems; the diagnostic radiological imaging system; the physician instruments; the pharmacy and central supply; the Fluid Therapy Subsystem; the restraints to be used for medical procedures; and the Safe Haven mode, which is a mode of station operation in which it is assumed that the HMF has been lost and the medical needs must be provided by the emergency medical equipment and supplies located in the Portable Emergency Provisions. Special attention is given to the pharmaceutical issues involved, including such as the product selection, oral medications, injectable medications, the effect of exposing medications to high vacuum, and the product shelf life.

Lloyd, Charles W.↗

Inferior vena caval masses identified by echocardiography

The most common cause of an inferior vena caval mass is renal cell carcinoma that extends through the lumen, occurring in 47 of 62 patients (85%). Detection of an inferior vena caval mass affects the surgical approach requiring cardiopulmonary bypass for resection when the mass extends to the heart.

NASA Discipline Cardiopulmonary↗

Kraken Camera System

Specification sheet for Kraken camera system being developed by NNSS Transformational Diagnostics and Imaging in Los Alamos. Will be shared internally and externally.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of Simulated and Experimentally Measured Detector Impulse Responses to Pulsed X-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-to-end performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗