Search NASA⌕ Search

SEARCH · Search NASA

Results for “Direct liquid extraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Amidoxime-functionalized materials and their use in extracting metal ions from liquid solutions

A method of producing a functionalized material that extracts metal ions from solution, the method comprising: (i) providing a precursor material having nitrile groups appended to its surface; and (ii) reacting said nitrile groups with hydroxylamine or a derivative thereof in the presence of a polar aprotic solvent at a temperature of 60-80° C. for at least 1 hour, to convert at least a portion of said nitrile groups to amidoxime and imide dioxime groups, followed by reaction with a base capable of hydrolyzing any remaining nitrile groups to carboxylic acid groups; wherein said functionalized material has a higher uranium absorption capacity than a functionalized material produced under same conditions except that the nitrile groups are reacted with hydroxylamine in only a protic solvent. The invention is also directed to functionalized materials produced by the above-described method, and methods for using the functionalized material for extracting metal ions from metal-containing solutions.

Janke, Christopher J.↗

Mercury Speciation via Direct Mercury Analyzer

Mercury has no known biological role, but is present in every living thing and widespread in the environment. As mercury enters an aqueous system, it is subject to methylation or demethylation. Methylmercury selectively partitions into biota and biomagnifies through the food chain. Nearly all methylmercury exposures in the U.S. occur through eating fish and shellfish that contain higher levels of methylmercury. Methyl mercury and other organomercury compounds are more toxic than inorganic mercury. Thus, monitoring and understanding mercury speciation are key to effective environmental management. It is particularly important to be able to separate and measure bioaccumulative-toxic species of mercury such as methyl mercury. We are developing a protocol for utilizing the Direct Mercury Analyzer (DMA-80) for mercury speciation of water samples and to monitor methylmercury (meHg). Objectives: - Advance the understanding of the performance of the direct mercury analysis (DMA) under a range of DOE relevant water chemistry conditions to quantify total mercury: - Demonstrate the applicability of DMA to analysis of typical DOE high level liquid 'tank' waste samples using nonradioactive simulants; Test innovative sorbents to extend the range of the direct mercury analyzer to environmental concentration levels. - Perform scoping tests to demonstrate proof of principle for the chemical reduction amalgamation modular microcolumns for mercury speciation: Examine various microcolumn configurations and document speciation performance for typical DOE high level liquid 'tank' waste samples using nonradioactive simulants; Perform tests to examine extending the speciation paradigm to environmental concentration levels. General Method: all samples analyzed using a direct mercury analyzer (DMA 80) which automates the following steps: 1) pyrolysis to release the mercury, 2) catalysis to convert all mercury to elemental, 3) amalgamation to trap the mercury, 4) desorption to release the mercury as a pulse and 5) spectroscopy to detect the mercury.. Instrument analyzes all mercury species in solids and liquids. The DMA 'eliminates' sample preparation, reduces labor, decreases waste, and results in more practical and cost effective methods. To test the performance of the DMA for DOE relevant conditions, we analyzed samples representative of at high (mg/L) tank waste concentrations in water and in diluted tank waste simulant and analyzed samples representative of environmental (ng/L levels) in water. High concentration samples were analyzed directly in the instrument. Low concentration samples were analyzed by concentrating the mercury onto sorbents such as silica thiol or a mixture of silica thiol and copper. The concentration was performed using microcolumns and placing the columns into the DMA (see below) or by mixing the sorbent into the bulk sample and then filtering ad analyzing the filter in the DMA. Speciation Methods: The speciation tests were based on the selective reduction of inorganic mercury ions - Hg{sup (+} {sup or} {sup 2+)} - to elemental mercury - Hg(0). The elemental mercury is then trapped by amalgamation into the metal. These reactions do not impact methyl mercury allowing for separation. All reactions were performed using powdered elemental copper. To demonstrate proof-of-principle for the selective collection of inorganic mercury, samples were exposed to different amounts of powdered copper (and a control with no copper). This was done using microcolumns and a vacuum box. The columns were placed directly on the DMA for analysis. All materials and conditions were tested using solutions of both inorganic mercury and methyl mercury and all trials were in triplicate. Results and Observations: Validated DMA for high concentration Hg samples such as DOE tank waste: - Liquid inHg - samples were stable on autosampler carousel and results were accurate; - Liquid meHg - samples required a stabilizer. Si-Thiol (0.02 g) in the sample boat generated reliable meHg results. Stabilizer can be added for routine operations. Successful 'proof of principal' in extending DMA range to near environmental levels - using both microcolumns and filtration; - Filtration - Adding Si-Thiol (0.5 g) to sample extracted both inHg and meHg and preserved sample. Handling filters was labor intensive. - Microcolumns - best performance using a combination of copper and Si-Thiol - columns clogged and flowed slowly in some cases; - Practical limit may be in the range of 1 to 5 ng/L due to blanks; - Path Forward - Test additional packing materials and methods to improve flow and consistency, and approaches to minimize blanks. Successful 'proof of principal' for Hg speciation using chemical reduction and amalgamation; - Copper microcolumns (0.5 g Cu) selectively trapped inHg for high concentration mercury samples; - Copper microcolumns (0.5 g Cu selectively trapped inHg for large volume samples at environmental concentrations; - Some sorption of me Hg so that separations not quantitative; - Path Forward - test additional packing materials and alternate eluents to better trap inHg and minimize meHg retention in column.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessments of advanced reactor heat supply to high temperature industrial unit operations: Heat Engines and Heat Pumps

In this report, the feasibility of employing Advanced Nuclear Reactors to supply the necessary high-quality heat to Industrial Processes is investigated. As a first step, the most relevant industrial applications that could benefit from this coupling were identified. Four industries including petroleum refining (distillation, catalyst regeneration, hydro-steam cracking), chemical polymers, steel manufacturing (metals annealing/soaking) and cement manufacturing (calcination of limestone and dolomite industries) were considered. An overview of the heat duties, i.e., the temperatures and thermal powers required by representative plants of the different processes, was provided. Secondly, the thermodynamic conditions of the steam produced by representative designs of Advanced Reactor concepts (Liquid Metal Fast Breeder Reactors, Molten Salt Reactors, and High Temperature Gas-cooled Reactors) were summarized. The comparison between the requirements of the industrial processes and the capabilities of the candidate nuclear power plants showed that only a few processes could benefit from the coupling. Although Advanced Reactors operate at higher temperatures than Light Water Reactors, the thermodynamic conditions of the generated steam flow rates are generally not suitable for the selected applications. At the same time, data indicate that most of the processes can be suitably supplied if the temperature of steam is elevated to 900 °C. One possible solution to boost the quality of the steam from the nuclear island involves the use of a heat pump. Based on a technology similar to that found in refrigerators and air conditioners, heat pumps extract heat from a source, elevate its temperature and transfer it to where it is needed. A simple numerical example illustrating the viability of this method is described. Specifically, the energy conversion cycle of a conventional Pressurized Water Reactor was extended to incorporate a compressor to raise the heating value of the steam produced by the reactor. Two reference configurations, i.e., one where the industrial process coupled to the nuclear power plant exhausts saturated liquid and the other where it exhausts saturated steam, were considered. The thermal efficiencies achievable by increasing the heating value of the reactor steam in this way are significantly greater than by direct electric heating.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

First results from the Qweak measurement of the proton's weak charge

The Qweak experiment has made the first direct measurement of the weak charge of the proton, $Q^p_W$, through precision measurement of the parity-violating asymmetry in elastic scattering of longitudinally polarized electrons from unpolarized protons. The data were taken in Hall C at Jefferson Laboratory, during 12 months of running over a 2 year period, ending in May 2012. A beam current of up to 180 $\mu$A on a 35 cm long liquid-hydrogen target produced a scattered electron flux of $\sim$6.5 GHz incident on the detectors with Q$^2\sim0.026\ (\mathrm{GeV}/c)^2$. It is expected that the weak charge of the proton will be extracted with a 4.1\% combined statistical and systematic uncertainty. The proton weak charge is suppressed in the Standard Model so that these data may be used to determine the weak mixing angle, $\sin^2\theta_W$, with a relative uncertainty of 0.3\%, providing a competitive measurement of the running of $\sin^2\theta_W$ to low $Q^2$. In addition, these data will impose a strong constraint on a combination of the vector weak charges of the $u$ and $d$ quarks, $C_{1u}$ and $C_{1d}$, which is distinct from and complimentary to the combination from measurements of parity violation in atomic systems, and thereby provide an independent constraint on physics beyond the Standard Model. A first look at a subset of the data will be presented.

Dalton, Mark↗

Profiling of adrenocorticotropic hormone and arginine vasopressin in human pituitary gland and tumor thin tissue sections using droplet-based liquid-microjunction surface-sampling-HPLC–ESI-MS–MS

Described here are the results from the profiling of the proteins arginine vasopressin (AVP) and adrenocorticotropic hormone (ACTH) from normal human pituitary gland and pituitary adenoma tissue sections using a fully automated droplet-based liquid microjunction surface sampling-HPLC-ESI-MS/MS system for spatially resolved sampling, HPLC separation, and mass spectral detection. Excellent correlation was found between the protein distribution data obtained with this droplet-based liquid microjunction surface sampling-HPLC-ESI-MS/MS system and those data obtained with matrix assisted laser desorption ionization (MALDI) chemical imaging analyses of serial sections of the same tissue. The protein distributions correlated with the visible anatomic pattern of the pituitary gland. AVP was most abundant in the posterior pituitary gland region (neurohypophysis) and ATCH was dominant in the anterior pituitary gland region (adenohypophysis). The relative amounts of AVP and ACTH sampled from a series of ACTH secreting and non-secreting pituitary adenomas correlated with histopathological evaluation. ACTH was readily detected at significantly higher levels in regions of ACTH secreting adenomas and in normal anterior adenohypophysis compared to non-secreting adenoma and neurohypophysis. AVP was mostly detected in normal neurohypophysis as anticipated. This work demonstrates that a fully automated droplet-based liquid microjunction surface sampling system coupled to HPLC-ESI-MS/MS can be readily used for spatially resolved sampling, separation, detection, and semi-quantitation of physiologically-relevant peptide and protein hormones, such as AVP and ACTH, directly from human tissue. In addition, the relative simplicity, rapidity and specificity of the current methodology support the potential of this basic technology with further advancement for assisting surgical decision-making.

59 BASIC BIOLOGICAL SCIENCES↗

Method and apparatus for continuous removal of carbon dioxide vapors from gases

A method for continuously removing carbon dioxide vapor from a carrier gas is disclosed. This method includes, first, causing direct contact of the carrier gas with a liquid mixture in a separation chamber, the carrier gas condensing at a lower temperature than the carbon dioxide vapor. A combination of chemical effects cause the carbon dioxide to condense, complex, or both condense and complex with the liquid mixture. The liquid mixture is chosen from the group consisting of: first, a combination of components that can be maintained in a liquid phase at a temperature below the carbon dioxide vapor's condensation point, whereby the carbon dioxide condenses into the liquid mixture; second, a combination of components where at least one component forms a chemical complex with the carbon dioxide vapor and thereby extracts at least a portion of the carbon dioxide vapor from the carrier gas; and third, a combination of components that can both be maintained in a liquid phase at a temperature below the carbon dioxide's condensation point, and wherein at least one component forms a chemical complex with the carbon dioxide vapor and thereby extracts at least a portion of the carbon dioxide vapor from the carrier gas. The liquid mixture is then reconstituted after passing through the separation chamber by a chemical separation process chosen to remove an equivalent amount of the carbon dioxide vapor from the liquid mixture as was removed from the carrier gas. The reconstituted liquid mixture is restored to temperature and pressure through heat exchange, compression, and expansion, as necessary, in preparation for recycling back to the separation chamber. The liquid mixture is then returned to the separation chamber. In this manner, the carrier gas leaving the exchanger has between 1% and 100% of the carbon dioxide vapor removed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray photoelectron spectroscopy of epitaxial films and heterostructures

X-ray photoelectron spectroscopy is a powerful experimental technique that yields invaluable information on a range of phenomena that occur in solids, liquids, and gasses. The binding energy and shape of a photoemission peak is sensitive not only to the atomic number, valence and orbital from which the electron is ejected, but also to complex many-body effects that accompany photoemission. Provided the influences of these different drivers of spectral line shapes can be disentangled, a great deal can be learned about the electronic structures of specific atoms in the material of interest. In addition to these largely local effects, the long-range electrostatic environment and resulting electric potential at the emitting atom have a direct effect on the measured binding energies. Furthermore, this fact opens the door to extracting information about the dependence of the valence and conduction band minima on depth below the surface, which in turn allows both vertical and lateral electrical transport data to be better understood. One purpose of this Report is to describe how the different physical forces described above impact spectral properties of complex oxide epitaxial films. This class of materials typically incorporates transition metal cations in different valences and of all the elements, these exhibit the most complex core-level spectra. A second purpose is to show how a comprehensive understanding of local physical effects in x-ray photoemission allows one to extract detailed information on internal electric fields and band edge discontinuities in heterostructures involving complex oxides from core-level line shapes.

47 OTHER INSTRUMENTATION↗

Spectroscopic On-Line Monitoring for Process Control and Safeguarding of Radiochemical Streams in Nuclear Fuel Reprocessing Facilities

There is a renewed interest worldwide to promote the use of nuclear power. The long term successful use of nuclear power is critically dependent upon adequate and safe processing and disposition of the spent nuclear fuel. Liquid-liquid extraction is a separation technique commonly employed for the processing of the dissolved spent nuclear fuel. Our approach is based on the prerequisite that real time monitoring of the solvent extraction flowsheets provides unique capability to quickly detect unwanted manipulations with fissile isotopes present in the radiochemical streams during reprocessing activities. Our ability to identify material intentionally diverted from a liquid-liquid solvent extraction contactor system was successfully tested using on-line process monitoring. A chemical diversion and detection from a solvent extraction scheme was demonstrated using a centrifugal contactor system operating with the simulant PUREX extraction system of Nd(NO3)3/nitric acid aqueous phase and TBP/dodecane organic phase. A portion of the feed from a counter-current extraction system was diverted while a continuous extraction experiment was underway; the spectroscopic on-line process monitoring system was simultaneously measuring the feed, raffinate and organic products streams. The amount observed to be diverted by on-line spectroscopic process monitoring was in excellent agreement with values based from known mass of sample directly taken (diverted) from system feed solution. We conclude that real-time spectroscopic process monitoring would be a useful tool for the IAEA to detect the diversion of nuclear material in a timely manner. This poster summarizes our methodology of on-line process monitoring and shows recent results of specific examples.

Pu, Np, U, Nd, PUREX, reprocessing, process monito↗

Turbulent mixing of a slightly supercritical van der Waals fluid at low-Mach number

Supercritical fluids near the critical point are characterized by liquid-like densities and gas-like transport properties. These features are purposely exploited in different contexts ranging from natural products extraction/fractionation to aerospace propulsion. Large part of studies concerns this last context, focusing on the dynamics of supercritical fluids at high Mach number where compressibility and thermodynamics strictly interact. Despite the widespread use also at low Mach number, the turbulent mixing properties of slightly supercritical fluids have still not investigated in detail in this regime. This topic is addressed here by dealing with Direct Numerical Simulations of a coaxial jet of a slightly supercritical van der Waals fluid. Since acoustic effects are irrelevant in the low Mach number conditions found in many industrial applications, the numerical model is based on a suitable low-Mach number expansion of the governing equation. According to experimental observations, the weakly supercritical regime is characterized by the formation of finger-like structures – the so-called ligaments – in the shear layers separating the two streams. The mechanism of ligament formation at vanishing Mach number is extracted from the simulations and a detailed statistical characterization is provided. Ligaments always form whenever a high density contrast occurs, independently of real or perfect gas behaviors. The difference between real and perfect gas conditions is found in the ligament small-scale structure. More intense density gradients and thinner interfaces characterize the near critical fluid in comparison with the smoother behavior of the perfect gas. A phenomenological interpretation is here provided on the basis of the real gas thermodynamics properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ON-LINE MONITORING FOR PROCESS CONTROL AND SAFEGUARDING OF RADIOCHEMICAL STREAMS AT SPENT FUEL REPROCESSING PLANTS

The International Atomic Energy Agency (IAEA) has established international safeguards standards for fissionable material at spent nuclear fuel reprocessing plants to ensure that significant quantities of weapons-grade nuclear material are not diverted from these facilities. Currently, methods to verify material control and accountancy (MC&A) at these facilities require time-consuming and resource-intensive destructive assay (DA). Leveraging new on-line non-destructive assay (NDA) techniques in conjunction with the traditional and highly precise DA methods may provide a more timely, cost-effective and resource-efficient means for MC&A verification at such facilities. Pacific Northwest National Laboratory (PNNL) is developing on-line NDA process monitoring technologies, including a spectroscopy-based monitoring system, to potentially reduce the time and resource burden associated with current techniques. The spectroscopic monitor continuously measures chemical compositions of the process streams including actinide metal ions (U, Pu, Np), selected fission products, and major non-radioactive flowsheet chemicals using UV-vis-near infrared and Raman spectroscopy. This paper provides an overview of the methods and reports our on-going efforts to develop and demonstrate the technologies. Our ability to identify material intentionally diverted from a liquid-liquid extraction contactor system was successfully tested using on-line process monitoring as a means to detect the amount of material diverted. A chemical diversion and detection of that diversion, from a solvent extraction scheme was demonstrated using a centrifugal contactor system operating a tributyl phosphate based extraction. A portion of the feed from a counter-current extraction system was diverted while a continuous extraction experiment was underway; the spectroscopic on-line process monitoring system was simultaneously measuring the feed, raffinate and organic products streams. The amount observed to be diverted by on-line spectroscopic process monitoring was in excellent agreement with values based from the known mass of sample directly diverted from system feed solution.

Np↗

Sesame-style decomposition of KS-DFT molecular dynamics for direct interrogation of nuclear models

A common paradigm used in the construction of equations of state is to decompose the thermodynamics into a superposition of three terms: a static-lattice cold curve, a contribution from the thermal motion of the nuclei, and a contribution from the thermal excitation of the electrons. While statistical mechanical models for crystals provide tractable framework for the nuclear contribution in the solid phase, much less is understood about the nuclear contribution above the % melt temperature $(C^{(nuc)}_ν≈3R)$ and how it should transition to the high-temperature limit $(C^{(nuc)}_ν\sim\frac{3}{2}R)$. Here, we describe an algorithm for extracting both the thermal nuclear and thermal electronic contributions from quantum molecular dynamics (QMD) simulations. We then use the VASP QMD package to probe thermal nuclear behavior of liquid aluminum at normal density to compare the results to semi-empirical models – the Johnson generic model, the Chisolm high-temperature liquid model, and the CRIS model. The thermal electronic energy is also calculated from the VASP results and compared to the Kohn-Sham calculations from QE-DFT simulations, Green’s function average atom calculations, and the Thomas-Fermi atomic model.

74 ATOMIC AND MOLECULAR PHYSICS↗

Research for amino acids in lunar samples.

The study was primarily directed toward the examination of Apollo 14 lunar fines for indigenous amino acids or materials which could be converted to amino acids on hydrolysis with 6 N hydrochloric acid. Initial experiments were conducted to confirm the integrity of the derivatization reactions and reagents, and to optimize the gas-liquid chromatographic (GLC) instrumental and chromatographic system for the separation and flame ionization detection of the amino acid derivatives. In studies on the recovery of amino acids added to lunar fines, low recoveries were obtained when 10 ng of each amino acid were added to 50 mg of virgin fines, but the subsequent addition of 50 ng of each to the previously extracted sample resulted in much higher recoveries.

Gehrke, C. W.↗

Ionic Liquid–Directed Nanoporous TiNb 2 O 7 Anodes with Superior Performance for Fast–Rechargeable Lithium–Ion Batteries

Nanoporous TiNb 2 O 7 (NPTNO) material is synthesized by a sol–gel method with an ionic liquid (IL) as the nanoporous structure directing template. NPTNO exhibits a high reversible capacity of 210 mAh g –1 even at the charging rate of 50 C and an excellent cyclability of half-cell capacity retention of 74% for 1000 cycles at 5 C and LiNi 0.5 Mn 1.5 O 4 -coupled full-cell capacity retentions of 81% and 87% for 1000 cycles at 1 C and 2 C, respectively. The studies of the 1000 cycled NPTNO electrode illustrate that the IL-directed mesoporous structure can enhance the cyclability of NPTNO cells due to the alleviation of repetitive mechanical stress and volume fluctuation induced by the repetitive Li + insertion-extraction processes. The measured Li + diffusion coefficients from the galvanostatic intermittent titration technique suggest that the IL-templating strategy indeed ensures the fast rechargeability of NPTNO cells based on the fast Li + diffusion kinetics. Benefitting from the nanoporous structure, NPTNO with unhindered Li + diffusion pathways achieves a superior rate capability in the titanium-based oxide materials and the best full-cell cyclability in the TNO materials. Furthermore, the templating potential of IL is demonstrated, and the superb electrochemical performance establishes the IL-directed NPTNO as a promising anode candidate for fast-rechargeable LIBs.

25 ENERGY STORAGE↗

Influence of Reservoir Convection on Heat Extraction with Closed-Loop Geothermal Systems

Over the past few years, advancements in closed-loop geothermal systems (CLGS), also called advanced geothermal systems (AGS), have sparked a renewed interest in these types of designs. CLGS have certain advantages over traditional and enhanced geothermal systems (EGS), including not requiring in-situ reservoir permeability, conservation of the circulating fluid, and allowing for different fluids, including working fluids directly driving a turbine at the surface. CLGS may be attractive in environments where water resources are limited, rock contaminants must be avoided, and stimulation treatments are not available (e.g., due to regulatory or technical reasons). Despite these advantages, CLGS have some challenges, including limited surface area for heat transfer and requiring long wellbores and laterals to obtain multi-MW output in conduction-only reservoirs. CLGS have been investigated in conduction-only systems. In this paper, we explore the impact of both forced and natural convection on the levels of heat extraction with a CLGS deployed in a hot wet rock reservoir. We bound potential benefits of convection by investigating liquid reservoirs over a range of natural and forced convective coefficients. Additionally, we investigate the effects of permeability, porosity, and geothermal temperature gradient in the reservoir on CLGS outputs. Reservoir simulations indicate that reservoir permeabilities of at least ~100 mD are required for natural convection to increase the heat output with respect to a conduction-only scenario. The impact increases with increasing reservoir temperature. When subject to a forced convection flow field, Darcy velocities of at least 10-7 m/s are required to obtain an increase in heat output.

advanced geothermal systems↗

Role of mineral flotation technology in improving bitumen extraction from mined Athabasca oil sands—II. Flotation hydrodynamics of water‐based oil sand extraction

Abstract Bitumen flotation hydrodynamics in water‐based oil sand extraction is critically reviewed by comparing aeration of oil sand slurries with mineral flotation. The role of the two‐stage particle‐bubble attachment model in flotation is emphasized as a means to accelerate bitumen flotation recovery. It involves the generation of micro/nanobubbles and their frosting on hydrophobic bitumen droplets, followed by their attachment to a flotation‐size bubble via its coalescence with the nanobubbles frosted on the bitumen. Nanobubble generation by hydrodynamic cavitation demonstrates that the size of nanobubbles can be reduced, and the number of nanobubbles increased by fast liquid flow, intensified agitation, high dissolved gas content and surfactant concentration. The mechanism of pre‐existing gas nuclei in enhancing nanobubble generation by cavitation is utilized to produce a large volume of stabilized nanobubbles for practical flotation, by continuously recirculating the stream through a gas saturation tank or a cavitation tube. The aeration of oil sand slurries in hydrotransport pipelines is analyzed based on its similarity to dissolved air flotation. Bitumen extraction recovery increased significantly with the presence of nanobubbles in the system. The role of improved flotation hydrodynamics in bitumen recovery is briefly discussed in terms of the Suncor operation using flotation columns to process oil sand middling streams. Future research should be directed at understanding bitumen flotation kinetics, optimizing size ranges of nanobubbles for maximized flotation recovery, minimizing wearing of cavitation tubes in industrial operations, and intensifying the role of in‐situ nanobubble nucleation on hydrophobic particles/bitumen droplets in flotation, especially for bitumen extraction from underperforming oil sands.

Zhou, Joe Z.↗

Hydrothermal Liquid Recovery of Rare Earth Elements and Critical Materials

This project demonstrated the technical viability of using tunable hydrothermal liquid (HTL) solutions to recover valuable minerals from a range of source materials. The effort focused upon rare earth elements (REE) and other minerals critical to the industrial security of the United States. This effort demonstrated, for the first time, that s, supercritical water (SCW) in particular, can: Extract critical and valuable minerals from a range of matrices ranging from rock ore to biomass; The process can be used to recover a wide range of minerals; This novel extraction chemistry can be cheap, simple, and nontoxic/”green”: The chemical extraction uses water, the cheapest industrial acid (sulfuric), and simple salts (i.e. sodium sulfate). However, other acids, salts, and additives could be used as appropriate. This Laboratory Directed Research and Development (LDRD) project identified that the process is complex with many interacting factors, but the benefits are significant if the complexities can be resolved. Challenges remain in the development of this technology and are described in this report. However, the results are positive, and commercial partners have already expressed interest. In summary, a novel, green, inexpensive mineral extraction process has been developed and demonstrated in a small batch reactor system. The effort provided information for an invention disclosure, proposal to DOE, and will support future business development efforts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Total Mercury Analysis Comparison: Deployment of Analytical Method for the Savannah River Site Liquid Waste System

A direct mercury analyzer (DMA; EPA 7473) and Cold Vapor Atomic Absorption Spectroscopy (CVAAS; EPA 245.2) have been used to analyze samples high in methylmercury and other forms of mercury with oxidation states of Hg o (elemental), Hg 1+ (mercurous), and/or Hg 2+ (mercuric) to determine analytical data equivalency for total mercury. The DMA instrument has been determined to be the preferred method based on both simulated and radioactive sample testing due to analytical results and ease of use in a radiological hood. SRNL made a number of modifications to the DMA instrument and analysis method to limit the amount of time personnel are required to work in a radiological environment. Equivalency is based on comparative statistical evaluation of the results from: spike solutions/simulants, Tank 50 samples, Mixed Analyte Performance Evaluation Program (MAPEP) samples, and Modular Caustic-Side Solvent Extraction Unit (MCU) solvent samples. SRNL performed a cross-comparison of results using CVAAS, DMA, and Inductively Coupled Plasma Mass Spectrometer (ICP-MS), as well as independent analysis from an offsite laboratory (using cold vapor sample processing with atomic fluorescence detection, EPA 1631). All data were within the combined uncertainty (2σ ± 20%) of the CVAAS and DMA methods

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

On-line removal of volatile fatty acids from CELSS anaerobic bioreactor via nanofiltration

The CELSS (controlled ecological life support system) resource recovery system, which is a waste processing system, uses aerobic and anaerobic bioreactors to recover plants nutrients and secondary foods from the inedible biomass. The anaerobic degradation of the inedible biomass by means of culture of rumen bacteria,generates organic compounds such as volatile fatty acids (acetic, propionic, butyric, VFA) and ammonia. The presence of VFA in the bioreactor medium at fairly low concentrations decreases the microbial population's metabolic reactions due to end-product inhibition. Technologies to remove VFA continuously from the bioreactor are of high interest. Several candidate technologies were analyzed, such as organic solvent liquid-liquid extraction, adsorption and/or ion exchange, dialysis, electrodialysis, and pressure driven membrane separation processes. The proposed technique for the on-line removal of VFA from the anaerobic bioreactor was a nanofiltration membrane recycle bioreactor. In order to establish the nanofiltration process performance variables before coupling it to the bioreactor, a series of experiments were carried out using a 10,000 MWCO tubular ceramic membrane module. The variables studied were the bioreactor slurry permeation characteristics, such as, the permeate flux, VFA and the nutrient removal rates as a function of applied transmembrane pressure, fluid recirculation velocity, suspended matter concentration, and process operating time. Results indicate that the permeate flux, VFA and nutrients removal rates are directly proportional to the fluid recirculation velocity in the range between 0.6 to 1.0 m/s, applied pressure when these are low than 1.5 bar, and inversely proportional to the total suspended solids concentration in the range between 23,466 to 34,880. At applied pressure higher than 1.5 bar the flux is not more linearly dependent due to concentration polarization and fouling effects over the membrange surface. It was also found that the permeate flux declines rapidly during the first 5 to 8 hours, and then levels off with a diminishing rate of flux decay.

Colon, Guillermo↗